20023-C-11-25-20 CG sf
Project Name: Client: Mix Number: Project Number: Ticket Number: Load Amount: Admixtures: Tested By: Date and Time: Compressive Strength of Concrete Test Specimens Field Test Data: (ASTM C143, C138, C173, C231, C31, C1064, and C511) Slump (Inches): Entrained Air (%): Concrete Temperature: Ambient Temperature: Test Results:Minimum:Maximum: Cylinder # Lab Test Data: (ASTM C39, C42, C617, and C1231) Break Age Cylinder Diameter (in) Area (in² ) Break Date Maximum Load (lbs) Break Type Compressive Strength (psi)Required 28 day Strength (psi) °F °F Reviewed By: Supplier: Test Location: Unit Weight (PCF):Set # : Cylinders Picked Up By: Date and Time: Hi / Low Temperatures Remarks: 28-day Average Strength 5,643 PSI MACU Call Center 5000 PSI 20023 19613 11 yds C. Garcia 11/25/20; 7:48am 4.25 5.0 60 25 518A 518E 518C 518B 518D 4 4 4 4 4 12/02/20 12/23/20 12/23/20 12/23/20 12/23/20 55,215 73,350 67,555 73,760 69,110 5 5,0004,392 5,835 5,374 5,867 5,498 Digitally signed by Jacob Christensen Date: 2020.12.23 08:19:58 -07'00' 12.57 Walters Ready Mix Exterior Slab 7 28 28 28 H 12.57 12.57 12.57 12.57 K. Drake 11/26/2020 2 2 2 2