HomeMy WebLinkAboutCHECKLIST - 06-00014 - 648 Centennial Loop - New SFRRESIDENTIAL PLAN CHECKLIST NNNNN�_�� (2003 International Residential Code) Date: Project: Zoning: 1J,iz/ Bilding Permit Nurnber, e5, Jab Address0 : r � s ee�� - Number of Stories: �� Basement��Yes�jNQ/Finnfn. Floor Area (sf)0. 1,e6& finished, Valuation: $ Permit Fee: $ unfinished, N� i Fixtures: � Plan Check Fee.: $ The following comments based on the 2003 edition of the Intemational Residential Code should be resolved 0 W 1 0 -It 0 V nerare a DuxIaing permit is issued. '10,111S correction list is not a building permit. The approval of plans and specifications does not permit the vialaiion of any section of the Intemationa-1 Residential Code or anv federal,, or local regulations, qr PLAN CHECK Awns To Scale zpicyPlot Plan Legible Y / Flood Plain mr- � Fl got 1 Foundation Plan Section showing construction details ,z AlWuilding Elevations Design Criteria (shall be 'Identified on plans as mind - 85 m.P.h., Snow - 35 lb. Per sq ft,) Truss Calculation Sheets &. -e�'''F1oor Joist Details Mechanical Des lgn Energy Calculations (R320 & Ch 11) B. Zoningeck one - in some cases LDR2 and MDR may apply) LDR / LDRI Lot area — LDR- 12,000 sq. ft. min. (width 80 ft. min) (width60 ft. min.).(LDRI du-olex - 10.000 so. ft. min _) & LDRI- 8,000 sq. ft. min C. Use ,���"Single Family Duplex (LDRI only - Conditional use exmifi2 D. Slet Backs {taken from eaves} xflnset back (32 ft. From curb) Note: 60% min of front yard green Rear set back (LDR 25 ft. & LDRI 20 ft.) Z/Sides set backs (6" for every ft. of building height with LAR - 7.5'min., & LDRI - Cmin) //xBluilding-Height (maximum 30 ft-) E.Yproper 'stings Size (as per Table X03. 1, use 1,500 psf unless soil hype is known, Table 401.4.1,for sai I bearing) r ZRtebar (2-#4 continuous) //Foofing Depth (36" below finished grade and ].2" below undisturbed sail; 18" to top of slab — interior) F. Foundation _ZFounda#ion walls wi rebax (city ordnance) IZ" Anchor Bolts with 2"x 2"x 3116" square washers (incl. interior bearing walls) R403.1.6 -A ZVFoolundation Drainage (foundations on sift sail shall be designed per R405) _ Damp proof anglVilaterproofing to finish grade. R406.1 (fnd. extends 6-"' min abase grade R404.1.6) "Crawl. space access of 18" x 24" min. R408.3 (may differ if meth appliance is in crawl space M 13 0 5.1.4) ---Cravvl Spare Ventilation/Insulation —I sf vent per 150 sf. (with. moisture barrier within Yof each corner (insulate walls vent to inside of home) R408-.2 �'Gradixxg slope away from ho -use. R401.3 G. Fr me Seismic Hold Downs and Braced Wall Panels (R602.10) �vrs jo�s�s sized as pex R50�.3, mood Ij�aists sized per n�anufr.1. Joists Under Load Beafing Partitions shah be doubled. R502.4 ZGirders sized per R502.5 or per manu.I-r. Tables for engineered products ---'Cantilevers (comply with R5023.3 or manufr instruction) 1 sf. per 1500 sq. ft.) and 0 9 4 Floor Sheathing (314" min for o� & Sl$"joistsjoists for oc) R5011 --,_-Wall (bearing and nonbearing) stud sizes, height & spacing per Table 602.3(5) R602*3 Headers in Bearing Wall shall be designed as per Tables 502.5(1&2) 8602.7 //Roof Trusses (Lesigned. according to Rafter and Truss 8802.10.1) 35 # Snow and 90 mph winds (Local Conditions) � 8o2.io.s� Attic Access 22" x 3011 min, opening p g H. Exterior Covering "Masonry and stucco shah have weather resistive barrier over exterior sheathing R703.2 & 7Q3.9.1 I. Roof Covering and Ventilation A0of Ventilation as per R806 Asphalt Shingles (slope>2.-12) w/ ice protection. (Other type: to comply w/ R905.—) J. Firewafls /Garage/House drywall. separation (protect ext. walls & beams supporting habitable space) R309.2 Door from Garage to douse (1 318" solid wood or steel door, or 20 min. fire -rated door) R309.1 TWo Family Lhvelling Separation (1 hr fire separation} Supporting structure also rated. 8317,1. —FTwin homes & Townhouses (2 hr separation & 4' overburn protection or parapet) R317.2 One hr wads parallel to and within 3 ft of property Zine w/ NQ openings. imauz Penetrations in previous 3 items to comply with 8317.3 K. General Requirements House Numbers R321 lialf Openable, 3sf vvindowar Mech. Ventilation in bathrooms, water closets, and similar rooms, R303.3 .� I nterior and exterior stair illumination shall nom ply vvx th 8303.6. ZABathroom Fixture �Iear�ncescomply with Figurek R307.2 ane room at least 120 sf.; Other habitc�Ule rooms 7� �f. min wl a mrn. dimension of 7 ft. R304 *areas w/ sloped ceilings less than 5 ft in height &furred ceilings less than 7 ft DD XOT comply *SD% or more of the required area" must be at least 7ft high in rooms iv/ sloped ceiling 0`�.� Egress clearance from window wells under cantilevered floors. R310-2 Glazing at hazardous Locations P%308 R310 /E.ImergencEgress in all sleeping rooms and basements with haNtable space ",..",-'One required Exit Door shall comply with R311-4 Landings at tap and bottom of stairways 8311.5.4, and each side of each exterior door. 8311.4.3 f! , ' Stair Rise /Run (7 314" mom. rise & 14" min. tread, nosing req'd if <11") ., 'Stair Width (36" ruin), Stairway Headroom (6' S" min.) Z --Handrails (34"to 3 8" above stair nasing)(R311.5) Special conditions for circular, spial and winder stair -ways and bulkhead enclosures 8311.5.8 f Stairway Protection (enclosed accessible space under stairs shall be covered vvxth X12" drywall) R311.2.2 l�J Guardra'Is complying with 8312 .'Handrails complying with R311.S.�G Smoke Alarms each bedroom and common area and one on each level.) (It 313) L. Energy "omes with glazing < 15 % of gross area of ext. walls (Townhouses < 2 5 %) to comply wl Chapter 1 1. * Diherwise shah meet requirements of I CC for respective building type. N1101.2 �''Vapar retarder on warm in minter side of walls, ceiling and floors R318 "*Water Heater heat traps IECC 504.7 /Duct sealing and insulation N1103.3&4 or IECC 503.3.3.3, 503.3.3.4.3 / 0111 Plans match quantities & values an a M. Mechanical "passing" RIEScheck compliance report batbroomstoilet roomsor storage closeis �Z40G.2as appliances not in bedrooms, Roam access 24" min vvid�hlAttic access clear opening 20x3O/Under floor r.o. 22x3O. M1305 Potential vent/connector offset ,:. 75% of total height (Exception provided by G2428) G2.427.694 Dryer Vent length 25' max w/ 8' transition (-5' per 90 deg turns) M1501.3 Gas "point of delivery" and material used to detennine pips sizing. G2413 I 1h