HomeMy WebLinkAboutCOMCHECK - 07-00634 - Just Sports - AdditionA
W.
2006 IECC
Report Date. 01/17/08
COMcheck Software Vers'ic
Envelope Co pll;
Data filename: :\ r win \40 J U -1 \DOCS JUSTSP-I.CCK
Section 'I : Project Information
Project T*Itla Just Sports Addition
Construction Site:
11, 54 Stacks Ave
Rexburg, ID 83440
Owner/Agent:
Chad Erikson
Just Sports
1154 Stocks Ave
Rexburg, I D 83440
-388
Section 2; general Information
Building Lo ti n (for weather date.):
Climate Zone:
Heating Degree Days (base 65 degrees F)-
Coo,ling Degree Days (base 50 degrees F:
Project Typo:
Vertical Glazing / Wall Area Pct.:
Activity Type(s
Warehouse
Rexburg, Idaho
b
8693
1.446
Addition
0%
Section 3: Requirements Checklist
Floor Area
Just Sports Addition
Revisions 1(17/2008
Designer/Contractor.
U to Allen
J W
1152 Bond Ave,
Rexburg, ID 83440
359-2309
Climate -Specific Requirements:
Component Name/DescHiption.
Roof 1Metal Building, , Standing Seam
F=.terior Wall 1: Metal Building Wall
Dont` 1: Insulated M tal, Non -Swinging
Door : Insulated (Metal, Swinging
Floor 1: 3 lab -On -Grade: Unht d, Vertical 3 ft.
Gross Area
r Perimeter
Cavity
I -Value
Cont.
-"glue
Proposed
LJ -Factor
Budget
et
U -Factor
3600 3&0 0.0 0.046 0.065
4800 19.0 0.0 0.070 0.057
560 --- --- 0.600 0.500
4 --- --- 0.00 0.700
(a) Budget -factors are used for software baseline calculations ONLY, and are not code requirements,
Air Leakage, Component Certification, and Vapor Retarder Requirements:
All joints and penetrations are caulked, gasketed or covered lth a moisture vapor -permeable wrapping material installed in
accordance with the manufacturer's installation instructions.
2. Windows, doors, and skylights certified as meetingleakage requirements.
❑ . Component F -value -fa tors labeled as certified.
Li . Insulation installed according to manufacturer's instructions, in substantial contact with the surface being insulated, and in a
manner that achieves the rated R-valua without compressing the insulation,
❑ . No roof insulation is installed on a suspended ceiling with removable ceiling panels.
Lj . Stair, elevator shaft vents, and other outdoor air intake and exhaust openings in the building en i p are equipped with motorized
dampers.
Just Sports Addition
r1TJ
Page 1 of
a 7, Cargo doors and loading dock doors are weather sealed.
LI . Recessed lighting fixtures are: i Type IC rated and sealed or k t ; or (ii) installed inside ars appropriate air -tight assembly
with, a 0.5 inch clearance from combustible materials and with 3 inches I r n from insulation m t ri .l
❑ . Building entrance doors have a vestibuleand equipped with closing devices.
Exceptions:
Building entrances with revolving doors.
Doors that open directly from a spice less than 3000 sq. ft. in area.
L]MVapor retarder in t ll d.
Section 4: Compliance Statement
Compliance Statement.- The proposed envelope design represented in this document is consistent with the building plans, speoifications
and other calculations submittedwith this permit application. The proposed envelope system has been designed to meet the 2006 IECC
requirements in COM check Version 3.4.1 and to comply with the rr and atory requirements ire thf, Requirements C her li t.
:m - Title
Jut Sports Addition
Signature
Date
Page of