HomeMy WebLinkAboutTRUSSES - 07-00557 - 593 E 5th S - New SFR0700557
593 E. 5th S.
N
iC o Q FILLMORE
o �� Q-811022
E2
Job
Truss
Truss Type
Qty
Ply
FILLMOREICANYON VIEW 9/7
0811022
A1G
ROOF TRUSS
1
1
Job Reference (optional)
a I OCK CONF rvGry I a-1r, gaw ra115, lu 63403, GLAT G.
7.000 s May 29 2007 MiTek Industries, Inc. Fri Sep 07 10:46:15 2007 Page 1
-2-0-0 6-1-12 12-3-8 14-3-8
2-0-0 6-1-12 6-1-12 2-0-0
=
scale = 12e.5
4M
12-3-8
12-3-8
LOADING (psf)
TCLL 35•0
SPACING 2-0-0
CSI
DEFL
in
(loc)
l/defl
Ud
PLATES GRIP
(Roof Snow=35.0)
Plates Increase 1.15
TC 0.73
Vert(LL)
-0.14
9
n/r
90
MT20 169/123
TCDL 8.0
Lumber Increase 1.15
BC 0.34
Vert(TL)
-0.16
9
n/r
80
BCLL 0.0
Rep Stress Incr NO
WB 0.11
Horz(TL)
0.00
8
n/a
n/a
BCDL 8.0
Code IRC2003ITP12002
(Matrix)
Wind(LL)
0.06
9
n/r
120
Weight: 53lb
g
LUMBER BRACING
TOP CHORD 2 X 4 SPF 1650F 1.5E TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2 X 4 SPF 165OF 1.5E BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
OTHERS 2 X 4 SPF-S Stud/Std
WEDGE
Left: 2 X 6 DF No.2, Right: 2 X 6 DF No.2
REACTIONS (lb/size) 2=404/12-3-8, 8=404/12-3-8, 12=140/12-3-8, 13=234/12-3-8, 14=99/12-3-8, 11=234/12-3-8, 10=99/12-3-8
Max Horz 2=115(LC 6)
Max Uplift2=-117(LC 7), 8=-136(LC 8), 13=-74(LC 7), 14=-184(LC 9), 11=-72(LC 8), 10=-184(LC 9)
Max Grav2=599(LC 2), 8=599(LC 3), 12=140(LC 1), 13=355(LC 2), 14=130(LC 2), 11=355(LC 3), 10=130(LC 3)
FORCES (lb) - Maximum Compression/Maximum Tension
TOP CHORD 1-2=0/191, 2-3=-163/78, 3-4=-107/67, 4-5=-125/90, 5-6=-125/82, 6-7=-107/52, 7-8=-163/45, 8-9=0/191
BOT CHORD 2-14=-1/121, 13-14=-1/121, 12-13=-1/121, 11-12=-1/121, 10-11=-1/121, 8-10=-1/121
WEBS 5-12=-118/0, 4-13=-295/78, 3-14=-196/74, 6-11=-295/76, 7-10=-196/74
NOTES
1) Wind: ASCE 7-98; 90mph; h=25ft; TCDL=4.8psf; BCDL=4.8psf; Category II; Exp C; enclosed; MW FRS interior zone; Lumber DOL=1.33
plate grip DOL=1.33.
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see MiTek "Standard Gable
End Detail"
3) TCLL: ASCE 7-98; Pf=35.0 psf (flat roof snow); Exp C; Fully Exp.
4) Unbalanced snow loads have been considered for this design.
5) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 35.0 psf on overhangs non -concurrent
with other live loads.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) All plates are 1.5x4 MT20 unless otherwise indicated.
8) Gable requires continuous bottom chord bearing.
9) Gable studs spaced at 2-0-0 oc.
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 117 lb uplift at joint 2, 136 lb uplift at joint 8, 74
lb uplift at joint 13, 184 lb uplift at joint 14, 72 lb uplift at joint 11 and 184 lb uplift at joint 10.
11) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSVTPI 1.
LOAD CASE(S) Standard
Q811022 181 I ROOF TRUSS 11 I 2
s May 29 2007 MiTek Industries, Inc. Fri Sep 07 10:46:17 2007 Page 1
-2-0-0 4-2-15 8-1-8 12-1-14 16-2-5 1 20-2-11 1 24-3-2 28-1-11 32-4-10
2-0-0 4-2-15 3-10-9 4-0-6 4-0-6 4-0-6 4-0-6 3-10-9 4-2-15
04 11 Scale = 1:63.0
a
I$
oxv n wcu = tuxiu = 10x10 = 10x10 = 8x8 = 30 II
4-2-15 8-1-8 12-1-14 16-2-5 20-2-11 24-3-2 28-1-11 32-4-10
4-2-15 3-10-9 4-0-6 4-0-6 4-0-6 4-0-6 3-10-9 4-2-15
LOADING (ps 35.0
TCLL
SPACING 1-0-0
CSI
DEFL in (loc) Vdefl Ud
PLATES GRIP
(Roof Snow=35.0)
Plates Increase 1.15
TC 0.18
Vert(LL) -0.09 14-15 >999 240
MT20 169/123
TCDL 8.0
Lumber Increase 1.15
BC 0.69
Vert(TL) -0.15 14-15 >999 180
BCDL
Rep Stress Incr NO
WB 0.96
Horz(TL) 0.01 13 n/a n/a
.0
BCDL 80
Code IRC20031TP12002
(Matrix)
Weight: 429lb
LUMBER BRACING
TOP CHORD 2 X 4 SPF 165OF 1.5E TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2 X 6 DF No.2 BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except:
WEBS 2 X 4 SPF 165OF 1.5E *Except' 6-0-0 oc bracing: 13-14,12-13.
W1 2 X 4 SPF-S Stud/Std, W3 2 X 4 SPF-S Stud/Std
W4 2 X 4 SPF-S Stud/Std, W4 2 X 4 SPF-S Stud/Std
W 3 2 X 4 SPF-S Stud/Std, W 1 2 X 4 SPF-S Stud/Std
REACTIONS (lb/size) 2=369/14-0-10, 19=366/14-0-10, 18=3/14-0-10, 17=5206/14-0-10, 13=5863/6-11-8, 12=-383/6-11-8
Max Horz 2=165(LC 6)
Max Uplift2=-52(LC 7), 19=-15(LC 6), 18=-102(LC 3), 17=-556(LC 7), 13=-614(LC 8), 12=-468(LC 2)
Max Grav2=500(LC 2), 19=435(LC 2), 18=74(LC 2), 17=5206(LC 1), 13=6051(LC 3), 12=67(LC 5)
FORCES (lb) - Maximum Compression/Maximum Tension
TOP CHORD 1-2=0/99, 2-3=-420/72, 3-4=-488/67, 4-5=-349/77, 5-6=-508/86, 6-7=-2321/298, 7-8=-2368/290, 8-9=-3954/426,
9.10=-3795/391, 10-11=-3883/381, 11-12=-107/720
BOT CHORD 2-19=-93/266, 18-19=-93/266, 17-18=-78/333, 17-20=-65/337, 16-20=-65/337,15-16=-294/3102, 14-15=-276/3036,
14-21=-572/103, 13-21=-572/103, 12-13=-572/103
WEBS 3-19=-359/31, 3-18=-11/126. 5-18=-291/34, 5-17=-11/69, 6-17=-4639/491, 6-16=-378/3767, 7-16=-315/2565, 8-16=-3132/376,
8-15=-385/3545, 9-15=-33/194, 9-14=-388/37, 11-14=-443/4568, 11-13=-5820/609
NOTES
1) 2-ply truss to be connected together with 10d (0.131 "x3") nails as follows:
Top chords connected as follows: 2 X 4 -1 row at 0-9-0 oc.
Bottom chords connected as follows: 2 X 6 - 2 rows at 0-7-0 oc.
Webs connected as follows: 2 X 4 -1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B). unless otherwise indicated.
3) Wind: ASCE 7-98; 90mph; h=25ft; TCDL=4.8psf; BCDL=4.8psf; Category II; Exp C; enclosed; MWFRS interior zone; Lumber DOL=1.33
plate grip DOL=1.33.
4) TCLL: ASCE 7-98; Pf=35.0 psf (flat roof snow); Exp C; Fully Exp.
5) Unbalanced snow loads have been considered for this design.
6) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 35.0 psf on overhangs non -concurrent
with other live loads.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 52 Ib uplift at joint 2, 15 lb uplift at joint 19, 102
lb uplift at joint 18, 556 lb uplift at joint 17, 614 lb uplift at joint 13 and 468 lb uplift at joint 12.
9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
10) Girder carries tie-in span(s): 41-2-10 from 14-0-0 to 25-5-0
LOAD CASE(S) Standard
Continued on page 2
Job
Truss
Truss Type
Qty
Ply
FILLMORE CANYON VIEW 9/7
0811422
B1
ROOF TRUSS
1
2
Job Reference (optional)
►.uuu s wy zu iuur m i eK incusmes, inc. rn Sep ut IUAW I i ZWI rage 2
LOAD CASE(S) Standard
1) Snow: Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 1-7=-43, 7-12=-43, 2-20=-8, 20-21=-856(F=-848), 12-21=-8
Job
Truss
Truss Type
Qty
Ply
FILLMORE/CANYON VIEW SU
0811022
C1
ROOF TRUSS
4
1
'
.lob Reference(optional)
STOCK COMPONENTS -IF, klaho Falls, ID 83403, CLAY G.
7.000 s May 29 2007 N6Tek Industries, Inc. Fri Sep 0710:46:19 2007 Page 1
-2-0-0 6-2-5 12-0-5 17-10-5 24-0-10 26-0-10
2-0-0 6-2-5 5-10-0 5-10-0 6-2-5 2-0-0
Scale 1/4-=1'
44 =
6-2-5 12-0-5 17-10-5 24-0-10
6-2-5 5-10-0 5-10-0 6-2-5
LOADING (psf)
TCLL 35.0
SPACING 2-0-0
CSI
DEFL
in
(loc)
I/defl
L/d
PLATES GRIP
(Roof Snow=35.0)
Plates Increase 1.15
TC 0.78
Vert(LL)
0.08
6-8
>999
240
MT20 169/123
TCDL 8.0
Lumber Increase 1.15
BC 0.38
Vert(TL)
-0.11
8-9
>999
180
BCLL 0.0
Rep Stress Incr YES
WB 0.48
Horz(TL)
0.05
6
n/a
nla
BCDL 8.0
Code IRC2003/TP12002
(Matrix)
Weight: 107 lb
LUMBER
TOP CHORD 2 X 4 SPF 1650F 1.5E
BOT CHORD 2 X 4 SPF 1650F 1.5E
WEBS 2 X 4 SPF 1650F 1.5E 'Except'
W 12 X 4 SPF-S Stud/Std, W 12 X 4 SPF-S Stud/Std
WEDGE
Left: 2 X 8 DF 1950F 1.7E, Right: 2 X 8 DF 195OF 1.7E
REACTIONS (lb/size) 2=1403/0-5-8, 6=1403/0-5-8
Max Horz 2=225(LC 6)
Max Uplift2=-154(LC 7), 6=-154(LC 8)
Max Grav 2= 1 730(LC 2), 6=1730(LC 3)
BRACING
TOP CHORD Structural wood sheathing directly applied or 4-7-5 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
FORCES (lb) - Maximum Compression/Maximum Tension
TOP CHORD 1-2=0/197, 2-3=-1849/79, 3-4=-1136/136, 4-5=-1136/136, 5-6=-1849/79, 6-7=0/197
BOT CHORD 2-10=-54/1266, 9-10=-54/1266, 8-9=0/1266, 6-8=0/1266
WEBS 3-10=0/227, 3-9=-729/118, 4-9=-47/681, 5-9=-729/119, 5-8=0/227
NOTES
1) Wind: ASCE 7-98; 90mph; h=25ft; TCDL=4.8psf; BCDL=4.8psf; Category II; Exp C; enclosed; MW FRS interior zone; Lumber DOL=1.33
plate grip DOL=1.33.
2) TCLL: ASCE 7-98; Pf=35.0 psf (flat roof snow); Exp C; Fully Exp.
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 35.0 psf on overhangs non -concurrent
with other live loads.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 154 lb uplift at joint 2 and 154 lb uplift at joint 6.
7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
Truss
Truss Type
Oty
Ply
FILLMORE/CANYON MEW 9/7
0811022
C1G
ROOF TRUSS
1
1
Job Reference (optional)
a t ut.n a,-tr, iounv raps, to o.AtN, L LAT u. 7.000 S My 29 2007 MTek Industries, Inc. Fri Sep 07 10:46:22 2007 Page 1
-2-0-0 12-0-5 24-0-10 26-0-10
2-0-0 12-0-5 12-0-5 2-0-0
Scale: 1/4 =T
4M =
24-0-10
24-0-10
Plate Offsets (X,Y): (2:0-2-5,Edgel, [14:0-2-5,Edsel. [17:0-2-8,0-3-01
LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl Ud PLATES GRIP
TCLL 35.0 Plates Increase 1.15 TC 0.73 Vert(LL) -0.13 15 n/r 90 MT20 169/123
(Roof Snow=35.0) Lumber Increase 1.15 BC 0.34 Vert(TL) -0.15 15 n/r 80
TCDL 8.0 Rep Stress Incr NO WB 0.27 Horz(TL) 0.01 14 n/a n/a
BCLL 0.0 Code IRC2003/TP12002
BCDL 8.0 (Matrix) Wind(LL) 0.06 15 n/r 120 Weight: 1251b
LUMBER BRACING _
TOP CHORD 2 X 4 SPF 165OF 1.5E TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2 X 4 SPF 165OF 1.5E BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2 X 4 SPF-S Stud/Std *Except* WEBS 1 Row at midpt 8-21
ST6 2 X 4 SPF 1650F 1.5E, ST5 2 X 4 SPF 165OF 1.5E
ST5 2 X 4 SPF 165OF 1.5E
WEDGE
Left: 2 X 6 OF No.2, Right: 2 X 6 DF No.2
REACTIONS (lb/size) 2=397/24-0-10, 21=167/24-0-10, 22=206/24-0-10, 23=203/24-0-10, 24=198/24-0-10, 25=235/24-0-10, 26=85/24-0-10,
20=206/24-0-10, 19=203/24-0-10, 18=197/24-0-10, 17=233/24-0-10, 16=85/24-0-10, 14=398/24-0-10
Max Horz2=225(LC 6)
Max Uplift2=-108(LC 5), 22=-45(LC 7). 23=-56(LC 7), 24=-46(LC 7), 25=-77(LC 7), 26=-195(LC 9), 20=-42(LC 8), 19=-57(LC 8),
18=46(LC 8). 17=-76(LC 8). 16=-194(LC 9), 14=-93(LC 8)
Max Grav2=593(LC 2), 21=176(LC 8). 22=313(LC 2), 23=294(LC 2), 24=288(LC 2), 25=345(LC 2), 26=111(LC 2), 20=313(LC 3)
, 19=294(LC 3), 18=287(LC 3), 17=343(LC 3), 16=112(LC 3), 14=594(LC 3)
FORCES (lb) - Maximum Compression/Maximum Tension
TOP CHORD 1-2=0/191, 2-3=-209/145, 3-4=-167/131, 4-5=-120/131, 5-6=-106/128, 6-7=-103/146, 7-8=-113/173, 8-9=-1121165,
9-10=-103/117, 10-11=-106/61, 11-12=-107/56, 12-13=-98/61, 13-14=-152/69, 14-15=0/191
BOT CHORD 2-26=-17/179, 25-26=-17/179, 24-25=-17/179, 23-24=-17/179, 22-23=-17/179, 21-22=-17/179, 20-21=-17/179, 19-20=-17/179,
18-19=-17/179,17-18=-17/179, 16-17=-17/179,14-16=-17/179
WEBS 8-21=-156/0, 7-22=-281/65, 6-23=-260/74, 5-24=-264/69, 4-25=-285/82, 3-26=-185/79, 9-20=-281/61, 10-19=-260/75,
11-18=-264/69, 12-17=-283/81, 13-16=-184/79
NOTES
1) Wind: ASCE 7-98; 90mph; h=25ft; TCDL=4.8psf; BCDL=4.8psf; Category II; Exp C; enclosed; MW FRS interior zone; Lumber DOL=1.33
plate grip DOL=1.33.
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see MiTek "Standard Gable
End Detail"
3) TCLL: ASCE 7-98; Pf=35.0 psf (flat roof snow); Exp C; Fully Exp.
4) Unbalanced snow loads have been considered for this design.
5) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 35.0 psf on overhangs non -concurrent
with other live loads.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) All plates are 1.5x4 MT20 unless otherwise indicated.
8) Gable requires continuous bottom chord bearing.
9) Gable studs spaced at 2-0-0 oc.
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 108 lb uplift at joint 2, 45 lb uplift at joint 22, 56
lb uplift at joint 23, 46 lb uplift at joint 24, 77 lb uplift at joint 25, 195 lb uplift at joint 26, 42 lb uplift at joint 20, 57 lb uplift at joint 19, 46 lb
uplift at joint 18, 76 lb uplift at joint 17, 194 lb uplift at joint 16 and 93 lb uplift at joint 14.
11) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced
ConflhV"OPI 1-
Job
Truss
Truss Type
My
Ply
FILLMORE/CANYON VIEW 917
0811022
C1G
ROOF TRUSS
1
1
Job Reference (optional)
r.uuu s way 1a zuu7 tau 1 eK mausmes, Inc. rn Sep 07 10.45:22 2007 Page 2
LOAD CASE(S) Standard
Job
Truss
Truss Type
Qty
Ply
FILLMORFJCANYON VIEW W
0811022
C2
ROOF TRUSS
3
1
Job Reference(optional)
I�
0
i.uuu s may zu ewr m i ex mausmes, otc. rn Sep ur iu:4o:4s ewi rage i
6-2-5 12-0-5 17-10-5 24-0-10 26-0-10
6-2-5 5-10-0 5-10-0 6-2-5 2-0-0
UG =
3
6-2-5 12-0-5 17-10-5 24-0-10
6-2-5 5-10-0 5-10-0 6-2-5
Scale = 1:47.4
LOADING (psf)
TCLL 35.0
SPACING 2-0-0
CSI
DEFL in (loc) I/defl L/d
PLATES GRIP
(Roof Snow=35.0)
Plates Increase 1.15
TC 0.78
Vert(LL) -0.10 1-9 >999 240
MT20 169/123
TCDL 8.0
Lumber Increase 1.15
BC 0.54
Vert(TL) -0.16 1-9 >999 180
BCLL 0.0
Rep Stress Incr YES
WB 0.53
Horz(TL) 0.05 5 n/a n/a
BCDL 8.0
Code IRC2003/TP12002
(Matrix)
Weight: 1051b
LUMBER
TOP CHORD 2 X 4 SPF 165OF 1.5E
BOT CHORD 2 X 4 SPF 1650F 1.5E
WEBS 2 X 4 SPF 165OF 1.5E *Except'
W 12 X 4 SPF-S Stud/Std, W 12 X 4 SPF-S Stud/Std
WEDGE
Left: 2 X 8 DF 1950F 1.7E, Right: 2 X 8 DF 195OF 1.7E
REACTIONS (lb/size) 1=1194/0-5-8, 5=1412/0-5-8
Max Horz 1=-253(LC 5)
Max Uplift1=-65(LC 7). 5=-155(LC 8)
Max Grav1=1408(LC 2). 5=1732(LC 3)
FORCES (lb) - Maximum Compression/Maximum Tension
TOP CHORD 1-2=-1926/98, 2-3=-1154/138, 3-4=-1150/146, 4-5=-1852/90, 5-6=0/197
BOT CHORD 1-9=-77/1343, 8-9=-77/1343, 7-8=0/1269, 5-7=0/1269
WEBS 2-9=0/233, 2-8=-806/150, 3-8=-62(705, 4-8=-730/119, 4-7=0/227
BRACING
TOP CHORD Structural wood sheathing directly applied or 4-2-4 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES
1) Wind: ASCE 7-98. 90mph; h=25ft; TCDL=4.8psf; BCDL=4.8psf. Category II; Exp C; enclosed; MW FRS interior zone; Lumber DOL=1.33
plate grip DOL=1.33.
2) TCLL: ASCE 7-98; Pf=35.0 psf (flat roof snow); Exp C; Fully Exp.
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 35.0 psf on overhangs non -concurrent
with other live loads.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 65 lb uplift at joint 1 and 155 lb uplift at joint 5.
7) This truss is designed in accordance with the 2003 Intemationat Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSVTPI 1.
LOAD CASE(S) Standard
Job
Truss
Truss Type
Qty
Ply
FILLMORE/CANYON VIEW EIR
0811022
C3
ROOF TRUSS
9
1
Job Reference dorsal
1�
i .vuu s rosy m zwr• PA i eK mausules, inc. rn z)ep ut ium):z4 zwr rage 1
6-2-5 12-0-5 17-10-5 24-0-10
6-2-5 5-10-0 5-10-0 6-2-5
US =
5x10 � 6 7 6 5x10
ISM 11 Us = 5x5 =
6-2-5 12-0-5 17-10-5 24-0-10
6-2-5 5-10-0 5-10-0 6-2-5
0
fo
Scale = 1:46.4
LOADING (psf)
TCLL 35.0
SPACING 2-0-0
CSI
DEFL in (loc) I/dell Ud
PLATES GRIP
(Roof Snow=35.0)
Plates Increase 1.15
TC 0.75
Vert(LL) -0.11 5-6 >999 240
MT20 1691123
TCDL 8.0
Lumber Increase 1.15
BC 0.57
Vert(TL) -0.18 5-6 >999 180
BCLL 0.0
Rep Stress Incr YES
WB 0.55
Horz(TL) 0.05 5 n/a n/a
BCDL 8.0
Code IRC2003/TP12002
(Matrix)
Weight: 97lb
LUMBER
TOP CHORD 2 X 4 SPF 165OF 1.5E
BOT CHORD 2 X 4 SPF 165OF 1.5E
WEBS 2 X 4 SPF 165OF 1.5E *Except-
W 12 X 4 SPF-S Stud/Std, W 1 2 X 4 SPF-S Stud/Std
REACTIONS (lb/size) 1=1212/0-5-8, 5=1212/Mechanical
Max Horz 1=-228(LC 5)
Max Upliftl=-66(LC 7), 5=-67(LC 8)
Max Grav 1=1415(LC 2), 5=1425(LC 3)
FORCES (lb) - Maximum Compression/Maximum Tension
TOP CHORD 1-2=-1937/100, 2-3=-1181/148, 3-4=-1182/148, 4-5=-1967/102
BOT CHORD 1-8=-97/1352, 7-8=-97/1352, 6-7=-19/1387, 5.6=-19/1387
WEBS 2-8=0/234, 2-7=-807/151, 3-7=-66/747, 4-7=-844/153, 4-6=0/238
BRACING
TOP CHORD Structural wood sheathing directly applied or 4-0-6 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES
1) Wind: ASCE 7-98; 90mph; h=25ft; TCDL=4.8psf, BCDL=4.8psf, Category II; Exp C; enclosed; MW FRS interior zone; Lumber DOL=1.33
plate grip DOL=1.33.
2) TCLL: ASCE 7-98; Pf=35.0 psf (flat roof snow); Exp C; Fully Exp.
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 66 lb uplift at joint 1 and 67 lb uplift at joint 5.
7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
Truss
Truss Type
Qty
Ply
FILLMORE/CANYON VIEW 907
Q811022
CR1
ROOF TRUSS
4
1
Job Reference (optional)
STOCK COMPONENTS -IF, Idaho Falls, ID 83403, CLAY G. 7.000 s May 29 2007 MiTek Industries, Inc. Fri Sep 07 10:46:26 2007 Page 1
-2-9-15 5-8-7 11-3-0
2-9-15 5-8-7 5-6-9
exe n
4
5-8-7 11-3-0
5-8-7 5-6-9
Scale- a+e-=r
LOADING (psf)
SPACING 1-0-0
CSI
DEFL
in
(loc)
I/deft
Ud
PLATES GRIP
TCLL 35.0
Plates Increase 1.15
TC 0.82
Vert(LL)
0.06
2-6
>999
240
MT20 169/123
(Roof Snaw=35.0)
Lumber Increase 1.15
BC 0.46
Vert(TL)
-0.07
5-6
>999
180
TCDL 8.0
Rep Stress Incr NO
WB 0.98
Horz(TL)
0.02
5
n/a
n/a
BCLL 0.0
Code IRC2003/TPI2002
(Matrix)
Weight: 46lb
BCDL 8.0
LUMBER BRACING
TOP CHORD 2 X 4 SPF 165OF 1.5E TOP CHORD
BOT CHORD 2 X 4 SPF 1650F 1.5E
WEBS 2 X 4 SPF-S Stud/Std 'Except' BOT CHORD
W 3 2 X 4 SPF 165OF 1.5E
REACTIONS (lb/size) 5=1029/Mechanical, 2=692/0-5-8
Max Horz2=329(LC 7)
Max Uplift5=-274(LC 7), 2=-35(LC 7)
Max Grav 5= 1 146(LC 2), 2=902(LC 2)
FORCES (lb) - Maximum Compression/Maximum Tension
TOP CHORD 1-2=0/103, 2-3=-1088/0, 3-4=-3331189, 4-5=-555/220
BOT CHORD 2-6=-195/883, 5-6=-195/883
WEBS 3-6=0/189, 3-5=-925/201
Structural wood sheathing directly applied or 5-9-2 oc pudins, except end
verticals.
Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES
1) Wind: ASCE 7-98; 90mph; h=25ft; TCDL=4.8psf; BCDL=4.8psf; Category II; Exp C. enclosed; MW FRS interior zone; Lumber DOL=1.33
plate grip DOL=1.33.
2) TCLL: ASCE 7-98; Pf=35.0 psf (flat roof snow); Exp C; Fully Exp.
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 35.0 psf on overhangs non -concurrent
with other live loads.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 274 lb uplift at joint 5 and 35 lb uplift at joint 2.
8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TP11.
9) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Snow: Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 1-2=-43
Trapezoidal Loads (plf)
Vert: 2=-5(F=19, B=19)-to-4=-242(F=-99, B=-99), 2=-0(F=4, B=4)-to-5=-45(F=-18, B=-18)
-2-0-0 4-3-8 8-0-0 12-7-15 17-5-11 22-1-10 25-10-2 i 30-1-10 32-1-10
2-0-0 4-3-8 3-8-8 4-7-15 4-9-11 4-7-15 3-8-8 4-3-8 2-0-0
Scale = 1:56.5
5x6 =
04 = 1.50 11 5x6 =
4-3-8 8-0-0 i 12-7-15 17-5-11 i 22-1-10 i 25-10-2 30-1-10
4-3-8 3-8-8 4-7-15 4-9-11 4-7-15 3-8-8 4-3-8
LOADING (psf)
SPACING 2-0-0
CSI
DEFL in
(loc) l/defl Ud
PLATES GRIP
TCLL 35.0
(Roof Snow=35.0)
Plates Increase 1.15
TC 0.45
Vert(LL) -0.14
12-13 >999 240
MT20 169/123
TCDL 8.0
Lumber Increase 1.15
BC 0.55
Vert(TL) -0.22
12-13 >999 180
Rep Stress Incr NO
WB 0.57
Horz(TL) 0.07
9 n/a n/a
BCLL 0.0
Code IRC2003/TP12002
(Matrix)
Weight: 339 lb
BCDL 8.0
LUMBER
BRACING
TOP CHORD 2 X 4 SPF 165OF 1.5E
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2 X 6 DF No.2
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2 X 4 SPF-S Stud/Std 'Except"
W4 2 X 4 SPF 165OF 1.5E, W4 2 X 4 SPF 1650F 1.5E
W4 2 X 4 SPF 1650F 1.5E
REACTIONS (lb/size) 2=3622/0-5-8, 9=3622/0-5.8
Max Horz 2=146(LC 6)
Max UpIlft2=-780(LC 7), 9=-780(LC 8)
Max Grav2=4315(LC 2). 9=4315(LC 3)
FORCES (lb) - Maximum Compression/Maximum Tension
TOP CHORD 1-2=0/205, 2-3=-5972/1165, 3-4=-5735/1242, 4-5=-5567/1237, 5-6=-5565/1238, 6-7=-5580/1239, 7-8=-5742/1244,
8-9=-5969/1165, 9-10=0/205
BOT CHORD 2-16=-985/4553, 15-16=-985/4553, 14-15=-992/4478, 13-14=-1214/5564, 12-13=-894/4483, 11-12=-840/4551,
9-11=-840/4551
WEBS 3-16=-174/118. 3-15=-165/256, 4-15=-435/1525, 4-14=-468/2053, 5-14=-621/73, 5-13=-126/138, 6-13=-505/29,
7-13=-464/2037, 7-12=-442/1557, 8-12=-169/268. 8-11=-187/119
NOTES
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2 X 4 - 1 row at 0-9-0 oc.
Bottom chords connected as follows: 2 X 6 - 2 rows at 0-9-0 oc.
Webs connected as follows: 2 X 4 -1 row at 0-9-0 oc.
2) A11 loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Wind: ASCE 7-98; 90mph; h=25ft; TCDL=4.8psf; BCDL=4.8psf; Category II; Exp C; enclosed; MWFRS interior zone; Lumber DOL=1.33
plate grip DOL=1.33.
4) TCLL: ASCE 7-98; Pf=35.0 psf (flat roof snow); Exp C; Fully Exp.
5) Unbalanced snow loads have been considered for this design.
6) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 35.0 psf on overhangs non -concurrent
with other live loads.
7) Provide adequate drainage to prevent water ponding.
8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 780 lb uplift at joint 2 and 780 lb uplift at joint 9.
10) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
11) Girder carries hip end with 8-0-0 end setback.
12) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 884 lb down and 295 lb up at 22-1-10.
and 884 lb down and 295 lb up at 8-0-0 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.
&"&.M(0%gStglndard
Job
Truss
Truss Type
My
Ply
FILLMOREJCANYON MEW SR
0811022
01
ROOF TRUSS
1
2
Job Reference (optional)
STOCK COMPONENTS -IF, Idaho Falls, V 83403, CLAY (3.
LOAD CASE(S) Standard
1) Snow: Lumber lncrease=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 1-4=-86, 4-7=43(17=43), 7-10=-86, 2-15=-16, 12-15=-200(F=-184), 9-12=-16
Concentrated Loads (lb)
Vert: 15=-884(F)12=-884(F)
7.000 5 May 28 2007 MiTeK Industries, Inc. Fri Sep 07 10:46:25 2007 Page 2
-2-0-0 5-2-3 10-0-0 15-0-13 20-1-10 24-11-7 30-1-10 32-1-10
2-0-0 5-2-3 4-9-13 5-0-13 5-0-13 4-9-13 5-2-3 2-0-0
Scale = 1:56.5
5x6 =
1.5x4 II 54 —
5 6
i�
5-2-3 10-0-0 15-0-13 20-1-10 24-11-7 30-1-10
5-2-3 4-9-13 5-0-13 5-0-13 4-9-13 5-2-3
LOADING (psf)
SPACING 2-0-0
CSI
DEFL in
(Ioc) I/defl Ud
PLATES GRIP
TCLL 35.0
(Roof Snow=35.0)
Plates Increase 1.15
TC 0.78
Vert(LL) -0.11
12 >999 240
MT20 169/123
TCDL 8.0
Lumber Increase 1.15
BC 0.41
Vert(TL) -0.18
12-13 >999 180
BCLL 0.0
Rep Stress Incr YES
WB 0.49
Horz(TL) 0,09
8 n/a n/a
BCDL 8.0
Code IRC2003ffP12002
(Matrix)
Weight: 151 lb
LUMBER
BRACING
TOP CHORD 2 X 4 SPF 185OF 1.5E
TOP CHORD
Structural wood sheathing directly applied or 3-10-9 oc purlins.
BOT CHORD 2 X 4 SPF 165OF 1.5E
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2 X 4 SPF 1650F 1.5E *Except*
W 12 X 4 SPF-S Stud/Std, W2 2 X 4 SPF-S Stud/Std
W 2 2 X 4 SPF-S Stud/Std, W 12 X 4 SPF-S Stud/Std
WEDGE
Left: 2 X 10 DF 195OF 1.7E, Right: 2 X 10 DF 1950F 1.7E
REACTIONS (lb/size) 2=1713/0-5-8, 8=171310-5.8
Max Horz2=-186(LC 5)
Max Uplift2=-152(LC 7), 8=-152(LC 8)
Max Grav2=2336(LC 2), 8=2336(LC 3)
FORCES (lb) - Maximum Compression/Maximum Tension
TOP CHORD 1-2=0/197, 2-3=-2837/88, 3-4=-2295/128, 4-5=-1848/116, 5-6=-1848/116, 6-7=-2295/128, 7-8=-2837/88, 8-9=0/197
BOT CHORD 2-14=-170/2053, 13-14=-170/2053, 12-13=-115/1691, 11-12=-24/1691, 10-11=0/2053, 8-10=0/2053
WEBS 3-14=0/177, 3-13=-464/86, 4-13=-13/390, 4-12=-132/730, 5-12=-751/138, 6-12=-132/730, 6-11=-13/390, 7-11=-464/86,
7-10=0/177
NOTES
1) Wind: ASCE 7-98; 90mph; h=25ft; TCDL=4.8psf; BCDL=4.8psf; Category II; Exp C; enclosed; MWFRS interior zone; Lumber DOL=1.33
plate grip DOL=1.33.
2) TCLL: ASCE 7-98; Pf=-35.0 psf (flat roof snow); Exp C; Fully Exp.
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 35.0 psf on overhangs non -concurrent
with other live loads.
5) Provide adequate drainage to prevent water ponding.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 152 lb uplift at joint 2 and 152 lb uplift at joint 8.
8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
Truss
Truss Type
Oty
Ply
FILLMORE/CANYON VIEW 9/7
0811022
D3
ROOF TRUSS
1
1
Job Reference(optional)
51 UUK L.UMI-UNtri I J-Ir, loan raps, w wvua, tLnT %2.
r .wV a,v, y cu &wr w... o ...uuau I—. , .... , .. wr -. . _V_ .
-2-0-0 6-2-3 12-0-0 15-0-13 18-1-10 23-11-7 30-1-10 32-1-10
2-0-0 6-2-3 5-9-13 3-0-13 3-0-13 5-9-13 6-2-3 2-0-0
stale = 1:56.5
6x10 MT18H=
30 =
6x10 MT18H=
6-2-3 12-0-0 18-1-10 23-11-7 30-1-10
6-2-3 5-9-13 6-1-10 5-9-13 6-2-3
LOADING (psf)
SPACING 2-0-0
CSI
DEFL
in (loc)
lldefl
Ud
I PLATES GRIP
TCLL•0
Plates Increase 1.15
TC 0.78
Vert(LL)
-0.10 12-13
>999
240
, MT20 169/123
(Roof Snow=35.0)
Lumber Increase 1.15
BC 0.40
Vert(TL)
-0.18 11-12
>999
180
MT18H 197/144
TCLL .0
Rep Stress Incr YES
WB 0.99
Horz(TL)
0.08 8
n/a
n/a
0
BCLL .0
Qrnt a n
Code IRC2003/TP12002
(Matrix)
Weight: 152lb
LUMBER
TOP CHORD 2 X 4 SPF 165OF 1.5E
BOT CHORD 2 X 4 SPF 1650F 1.5E
WEBS 2 X 4 SPF 165OF 1.5E *Except-
W 1 2 X 4 SPFS Stud/Std, W 2 2 X 4 SPF-S Stud/Std
W2 2 X 4 SPF-S Stud/Std, W 12 X 4 SPF-S Stud/Std
WEDGE
Left: 2 X 10 DF 195OF 1.7E, Right: 2 X 10 DF 1950F 1.7E
REACTIONS (lb/size) 2=1713/0-5-8, 8=1713/0-5-8
Max Horz 2=-223(LC 5)
Max Uplift2=-161(LC 7), 8=-161(LC 8)
Max Grav2=2252(LC 2), 8=2252(LC 3)
BRACING
TOP CHORD Structural wood sheathing directly applied or 3-8-1 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 5-12. 5-11
FORCES (lb) - Maximum Compression/Maximum Tension
TOP CHORD 1-2=0/197, 2-3=-2684/77, 3-4=-1988/123, 4-5=-1402/145, 5-6=-1402/146, 6-7=-1990/124, 7-8=-2684/77, 8-9=01197
BOT CHORD 2-13=-140/1920, 12-13=-140/1920, 11-12=-41/1358, 10-11=0/1920, 8-10=0/1920
WEBS 3-13=0/216, 3-12=-667/118, 4-12=-5/636, 5-12=-504/148, 5-11=-506/147, 6-11=-5/637, 7-11=-666/118, 7-10=0/216
NOTES
1) Wind: ASCE 7-98; 90mph; h=25ft; TCDL=4.8psf; BCDL=4.8psf; Category 11; Exp C; enclosed; MW FRS interior zone; Lumber DOL=1.33
plate grip DOL=1.33.
2) TCLL: ASCE 7-98; Pf=35.0 psf (flat roof snow); Exp C; Fully Exp.
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 35.0 psf on overhangs non -concurrent
with other live loads.
5) Provide adequate drainage to prevent water ponding.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) All plates are MT20 plates unless otherwise indicated.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 161 lb uplift at joint 2 and 161 lb uplift at joint 8.
9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job Truss Truss Type ty
Q811022 104 I ROOF TRUSS I I Ply
Idaho Falls, ID 83403, CLAY G.
7.000 s May 29 2007 MiTek Industries, Inc. Fri Sep 07 10:46:40 2007 Page 1
-2-0-0 7-2-3 14-0-0 16-1-10 22-11-7 30-1-10
2-0-0 7-2-3 6-9-13 2-1-10 6-9-13 7-2-3
scale = 1:5e.4
Sx8 = WO MT18H=
7-2-3 14-0-0 116-1-101 22-11-7 _ _ _, 30-1-10
7-2-3 6-9-13 2-1-10 6-9-13 7-2-3
LOADING (psf)
SPACING 2-0-0
CSI
DEFL in
(loc) Vdefl Ud
PLATES GRIP
TCLL 35.0
Plates Increase 1.15
TC 0.97
Vert(LL) -0.17
7-8 >999 240
MT20 169/123
(Roof Snow=35.0)
Lumber Increase 1.15
BC 0.75
Vert(TL) -0.28
7-8 >999 180
MT18H 197/144
TCDL 8.0
Rep Stress Incr YES
WB 0.22
Horz(TL) 0.08
7 n/a n/a
BCLL 0.0
BCDL 8.0
Code IRC2003/TPI2002
(Matrix)
Weight: 146lb
LUMBER
BRACING
TOP CHORD 2 X 4 SPF 1650F 1.5E
TOP CHORD
Structural wood sheathing directly applied.
BOT CHORD 2 X 4 SPF 165OF 1.5E
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2 X 4 SPF 1650F 1.5E -Except-
WEBS
1 Row at midpt 3-10. 4-9. 6-9
W 12 X 4 SPF-S Stud/Std, W 12 X 4 SPF-S Stud/Std
WEDGE
Left: 2 X 6 DF No.2
REACTIONS (lb/size) 7=1506/0-5-8, 2=1721/0-5-8
Max Horz 2=289(LC 6)
Max Uplift7=-79(LC 8), 2=-169(LC 7)
Max Grav7=1832(LC 3), 2=2153(LC 2)
FORCES (lb) - Maximum Compression/Maximum Tension
TOP CHORD 1-2=0/197, 2-3=-2494/98, 3-4=-1640/163, 4-5=-1106/175, 5-6=-1669/156, 6-7=-2562/121
BOT CHORD 2-11=-128/1749, 10-11=-129/1747, 9-10=-38/1081, 8-9=-10/1818, 7-8=-10/1818
WEBS 3-11=0/276, 3-10=-854/146, 4-10=-54/595, 4-9=-522/538, 5-9=-71/699, 6-9=-919/174, 6-8=0/279
NOTES
1) Wind: ASCE 7-98; 90mph; h=25ft; TCDL=4.8psf, BCDL=4.8psF, Category II; Exp C; enclosed; MW FRS interior zone; Lumber DOL=1.33
plate grip DOL=1.33.
2) TCLL: ASCE 7-98; Pf=35.0 psf (flat roof snow); Exp C; Fully Exp.
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 35.0 psf on overhangs non -concurrent
with other live loads.
5) Provide adequate drainage to prevent water ponding.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) All plates are MT20 plates unless otherwise indicated.
8) This truss requires plate inspection per the Tooth Count Method when this truss is chosen for quality assurance inspection.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 79 lb uplift at joint 7 and 169 lb uplift at joint 2.
10) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
Truss
Truss Type
Qty
Ply
FILLMORE/CANYON MEW S 7
i Q811022
D5
ROOF TRUSS
1
2
,lob Reference(optional)
STOCK COMPONENTS -IF, Idaho Falls, ID U3403, CLAY U.
1.UUU S Nay ZU LWf m 1 eK InauSvieS. InG. rn ow Ui iv:vo:v 1 cwr rdvu 1
-2-0-0 , 5-1-11 9-8-5 14-3-0 1,5-10-1p 20-5-5 24-11-15 30-1-10
2-0-0 5-1-11 4-6-11 4-6-11 1-7-10 4-6-11 4-6-11 5-1-11
Scale = 1:57.1
8x6 =
8x8 =
5-1-11 9-8-5 , 14-3-0 1,5-10-1p 20-5-5 24-11-15 30-1-10 ,
5-1-11 4-6-11 4-6-11 1-7-10 4-6-11 4-6-11 5-1-11
LOADING (psf)
TCLL 35.0
(Roof Snow--35.0)
TCDL 8.0
BCLL 0.0
BCDL 8.0
SPACING 1-0-0
Plates Increase 1.15
Lumber Increase 1.15
Rep Stress Incr NO
Code IRC20031TP12002
CSI
TC 0.64
BC 0.78
WB 0.65
(Matrix)
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
in (loc) Vdefl Ud
-0.18 12-13 >999 240
-0.31 12-13 >999 180
0.09 10 n/a n/a
PLATES GRIP
MT20 169/123
Weight: 401 lb
LUMBER
BRACING
TOP CHORD 2 X 4 SPF 165OF 1.5E
TOP CHORD Structural wood sheathing directly applied or 3-11-15 oc purlins.
BOT CHORD 2 X 6 DF No.2 *Except*
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
82 2 X 6 DF 180OF 1.6E
WEBS 2 X4 SPF 165OF 1.5E'ExcepV
W2 2 X 4 SPF-S Stud/Std, W2 2 X 4 SPF-S Stud/Std
WEDGE
Right: 2 X 8 DF 195OF 1.7E
REACTIONS (lb/size) 10=7719/0-5-8.2=3635/0-5-8
Max Horz2=146(LC 6)
Max Upliftl 0=-1 058(LC 8), 2=-490(LC 7)
Max Grav 1 0=7875(LC 3), 2=3844(LC 2)
FORCES (lb) - Maximum Compression/Maximum Tension
TOP CHORD 1-2=0/102, 2-3=-5725/696, 3-4=-5534/717, 4-5=-5446/729, 5-6=-5270/752, 6-7=-4493/666, 7-8=-5709/811, 8-9=-8085/1105,
9-10=-10622/1425
BOT CHORD 2-16=-583/4433, 15-16=-583/4433, 15-17=-571/4357, 14-17=-571/4357, 13-14=-545/4166, 12-13=-820/6392,
11-12=-1093/8336, 10-11=-1093/8336
WEBS 3.16=-51/66, 3-15=-99/98, 5-15=-4/196, 5-14=-368/65, 6-14=-161/1160, 6-13=-354/2175, 7-13=-461/3202, 8-13=-3583/539,
8-12=-600/4240,9-12=-2539/386,9-11=-410/2971
NOTES
1) 2-ply truss to be connected together with 10d (0.131 "x3") nails as follows:
Top chords connected as follows: 2 X 4 - 1 row at 0-9-0 oc.
Bottom chords connected as follows: 2 X 6 - 2 rows at 0-7-0 oc.
Webs connected as follows: 2 X 4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Wind: ASCE 7-98; 90mph; h=25ft; TCDL=4.8psf, BCDL=4.8psf; Category II; Exp C; enclosed; MWFRS interior zone; Lumber DOL=1.33
plate grip DOL=1.33.
4) TCLL: ASCE 7-98; Pf=35.0 psf (flat roof snow); Exp C; Fully Exp.
5) Unbalanced snow loads have been considered for this design.
6) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 35.0 psf on overhangs non -concurrent
with other live loads.
7) Provide adequate drainage to prevent water ponding.
8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1058 lb uplift at joint 10 and 490 lb uplift at joint
2.
10) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
11) Girder carries tie-in span(s): 24-0-10 from 13-0-0 to 30-1-10
Continued on page 2
LOAD CASE(R ) Standard
Job
Truss
Truss Type
Qty
Ply
FIL MOREICANYON VIEW 2f7
Q811022
D5
ROOF TRUSS
1
2
Job Reference (optional)
S I UUA UUMIjUNM i b-ir, wano raus, to oa4uo, l.W1T u.
LOAD CASE(S) Standard
1) Snow: Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 1-6=-43, 6-7=-43, 7-10=-43, 2-17=-8, 10-17=-584(F=-576)
.0 0 IYIpy LU &V I IV. Ion II Iv You Iw, ...v. . .. —W . rvv. . -%I- r
Job
Truss
Truss Type
Qty
Ply
FILLMORE/ CANYON VIEW 9/7
0811022
E1
ROOF TRUSS
3
1
Job Reference (optional)
.i I lJUf\ {.rVIVY "Nr-IV I J-Ir. K101 K! resim. Iu v.Ytvo, L.I.J v v. I ........, ..-., -- -..... ... ...................... .-. ... -T _.
-2-0-0 5-6-5 11-0-10 13-0-10
2-0-0 5-6-5 5-6-5 2-0-0
Scale = 126.4
US =
3
F0,
,
5-6-5 11-0-10
5-6-5 5-6-5
LOADING (psf)
SPACING
2-0-0
CSI
DEFL
in (loc)
I/defl
Ud
TCLL 35.0
Plates Increase
1.15
TC 0.78
Vert(LL)
0.05 4-6
>999
240
(Roof Snow=35.0)
Lumber Increase
1.15
BC 0.34
Vert(TL)
-0.04 4-6
>999
180
TCDL 8.0
Rep Stress Incr
YES
WB 0.14
Horz(TL)
0.01 4
n/a
n/a
BCLL 0.0
Code IRC2003/TP12002
(Matrix)
BCDL 8.0
LUMBER
TOP CHORD 2 X 4 SPF 1650F 1.5E
BOT CHORD 2 X 4 SPF 165OF 1.5E
WEBS 2 X 4 SPF-S Stud/Std
WEDGE
Left: 2 X 8 DF 195OF 1.7E, Right: 2 X 8 DF 195OF 1.7E
REACTIONS (lb/size) 2=740/0-5-8, 4=740/0-5-8
Max Horz 2=103(LC 6)
Max Uplift2=-124(LC 7), 4=-124(LC 8)
Max Grav2=970(LC 2), 4=970(LC 3)
FORCES (lb) - Maximum Compression/Maximum Tension
TOP CHORD 1-2=0/197, 2-3=-627/29, 3-4=-627/29, 4-5=0/197
BOT CHORD 2-6=-16/341, 4-6=-16/341
WEBS 3-6=-24/213
PLATES GRIP
MT20 1691123
Weight: 43 lb
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purl ins.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
NOTES
1) Wind: ASCE 7-98; 90mph; h=25ft; TCDL=4.8psf; BCDL=4.8psf; Category 11; Exp C; enclosed; MWFRS interior zone; Lumber DOL=1.33
plate grip DOL=1.33.
2) TCLL: ASCE 7-98; Pf=35.0 psf (flat roof snow); Exp C; Fully Exp.
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 35.0 psf on overhangs non -concurrent
with other live loads.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 124 lb uplift at joint 2 and 124 lb uplift at joint 4.
7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
0811022 1 E1G I ROOF TRUSS
ID 83403.
1
Job Reference (optional)
00 s May 29 2007 M9Tek Industries, Inc. Fri Sep 07 10:46:45 2007 Page 1
-2-0-0 5-6-5 11-0-10 13-0-10
2-0-0 5-6-5 5-6-5 2-0-0
Scale = 1:28.4
40 =
R
11-0-10
11-0-10
LOADING (psf)
SPACING 2-0-0
CSI
DEFL
in
(loc)
Udefl
L/d
PLATES GRIP
TCLL 35.0
Plates Increase 1.15
TC 0.73
Vert(LL)
-0.12
9
n/r
90
MT20 169/123
(Roof Snow=35.0)
Lumber Increase 1.15
BC 0.35
Vert(TL)
-0.14
9
n/r
80
TCDL 8.0
Rep Stress Incr NO
WB 0.10
Horz(TL)
0.00
8
n/a
n/a
BCLL 0.0
Code IRC2003/TP12002
(Matrix)
Wind(LL)
0,06
9
n/r
120
Weight: 48lb
LUMBER BRACING
TOP CHORD 2 X 4 SPF 165OF 1.5E TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2 X 4 SPF 165OF 1.5E BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
OTHERS 2 X 4 SPF-S Stud/Std
WEDGE
Left: 2 X 6 DF No.2, Right: 2 X 6 DF No.2
REACTIONS (lb/size) 2=413/11-0-10, 8=413/11-0-10, 12=138/11-0-10, 13=240/11-0-10, 14=21/11-0-10, 11=240/11-0-10, 10=21/11-0-10
Max Horz2=103(LC 6)
Max Uplift2=-143(LC 7). 8=-161(LC 8). 13=-74(LC 7), 14=-260(LC 9), 11=-72(LC 8), 10=-260(LC 9)
Max Grav2=616(LC 9). 8=616(LC 9). 12=138(LC 1), 13=363(LC 2), 14=79(LC 5). 11=363(LC 3), 10=79(LC 6)
FORCES (lb) - Maximum Compression/Maximum Tension
TOP CHORD 1-2=0/191, 2-3=-151/74, 3-4=-103/62, 4-5=-125/83, 5-6=-125/75, 6-7=-103/56, 7-8=-151/44, 8-9=0/191
BOT CHORD 2-14=-2/113, 13-14=-2/113, 12-13=-2/113, 11-12=-2/113, 10-11=-2/113, 8-10=-2/113
WEBS 5-12=-116/0, 4-13=-302/80, 3-14=-128/107, 6-11=-302/78, 7-10=-128/107
NOTES
1) Wind: ASCE 7-98; 90mph; h=25ft; TCDL=4.8psf; BCDL=4.8psf; Category 11; Exp C; enclosed; MWFRS interior zone; Lumber DOL=1.33
plate grip DOL=1.33.
2) Truss designed for wind loads In the plane of the truss only. For studs exposed to wind (normal to the face), see MiTek "Standard Gable
End Detail"
3) TCLL: ASCE 7-98; Pf=35.0 psf (flat roof snow); Exp C; Fully Exp.
4) Unbalanced snow loads have been considered for this design.
5) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 35.0 psf on overhangs non -concurrent
with other live loads.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) All plates are 1.5x4 MT20 unless otherwise indicated.
8) Gable requires continuous bottom chord bearing.
9) Gable studs spaced at 2-0-0 oc.
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 143 lb uplift at joint 2, 161 lb uplift at joint 8, 74
lb uplift at joint 13, 260 lb uplift at joint 14. 72 lb uplift at joint 11 and 260 ib uplift at joint 10.
11) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSVTPI 1.
LOAD CASE(S) Standard
Job
Truss
Truss Type
0ty
Ply
FILLMOREICANYON VIEW 9f/
0811022
E2
HOW E
1
2
....
Job Reference (optional)
IC-1. I-A.r ..... Iw ITA 0.... n7 4n•AP•AQ 9M7 one 1
STOCK COMPONENTS -IF, Idaho Falls, IL) BMW. GLAY G.
A 1YIoy GO LW1 11. 1 - 1I 1vw11 .,.... 1v
3-0-11 5-6-5 8-0-0 11-0-10
3-0-11 2-5-10 2-5-10 3-0-11
Stale = 1:23.2
Us II
30 4-
---
3-0-11 5-6-5
8-0-0 11-0-10
3-0-11 2-5-10
2-5-10 3-0-11
Plate Offsets (X Y): (1:0 1 10,0 1 81 (5:0 1-10,0-1-81
LOADING (psf)
SPACING 1-0-0
CSI
DEFL
in (loc) I/deft Ud
PLATES GRIP
TCLL 35•0
Plates Increase 1.15
TC 0.12
Vert(LL)
-0.03 7 >999 240
MT20 169/123
(Roof Snow=35.0)
Lumber Increase 1.15
BC 0.43
Vert(TL)
-0.05 7-8 >999 180
TCDL 8.0
Rep Stress Incr NO
WB 0.93
Horz(TL)
0.01 5 n/a n/a
BCLL 0.0
Code 1RC2003frP12002
(Matrix)
Weight: 106lb
BCDL 8.0
LUMBER
TOP CHORD 2 X 4 SPF 165OF 1.5E
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purtins.
BOT CHORD 2 X 6 DF No.2
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2 X 4 SPF-S Stud/Std
REACTIONS (lb/size) 1=2711/0-5-815=2711/0-5-8
Max Horz 1=52(LC 6)
Max Upliftl=-274(LC 7), 5=-274(LC 8)
Max Grav 1=2758(LC 2), 5=2758(LC 3)
FORCES (lb) - Maximum Compression/Maximum Tension
TOP CHORD 1-2=-3276/327, 2-3=-2283/249, 3-4=-2283/249, 4-5=-3276/328
BOT CHORD 1-8=-259/2522, 7-8=-259/2522, 6-7=-242/2522, 5-6=-242/2522
WEBS 2-8=-114/1181, 3-7=-269/2540, 4-6=-114/1181, 2-7=-972/119, 4-7=-972/119
NOTES
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2 X 4 - 1 row at 0-9-0 oc.
Bottom chords connected as follows: 2 X 6 - 2 rows at 0-7-0 oc.
Webs connected as follows: 2 X 4 -1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Wind: ASCE 7-98; 90mph; h=25ft; TCDL=4.8psf; BCDL=4.8psf: Category II; Exp C; enclosed; MW FRS interior zone; Lumber DOL=1.33
plate grip DOL=1.33.
4) TCLL: ASCE 7-98; Pf=35.0 psf (fiat roof snow); Exp C; Fully Exp.
5) Unbalanced snow loads have been considered for this design.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 274 lb uplift at joint 1 and 274 lb uplift at joint 5.
8) This truss is designed in accordance with the 2003 international Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSVTPI 1.
9) Girder carries tie-in span(s): 19-6-6 from 0-0-0 to 11-0-10
LOAD CASE(S) Standard
1) Snow: Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 1-5=-469(F=-461), 1-3=-43, 3-5=-43
Ply
0811022
F1
Falls,
ROOF TRUSS
2 I,
7.000 s
10:46:46 2007
6-9-8 13-5-3 20-0-15 26-8-10 33-2-10 36-11-2 41-2-10 43-2-10
6-9-8 6-7-12 6-7-12 6-7-12 6-6-0 3-8-8 4-3-8 2-0-0
Scale = 1:71.8
6A =
30 II 8x10 = 1.5A 11 34 = 3x8 = 1.50 II
o e 5 6
5x8 = 20 II 8x8 = 20 II 8x10 = 6x6 = 20 II
6-9-8 13-5-3 20-0-15 26-8-10 33-2-10 36-11-2 41-2-10
6-9-8 6-7-12 6-7-12 6-7-12 6-6-0 3-8-8 4-3-8
LOADING (psf)
SPACING 2-0-0
CSI
DEFL
in (loc) l/defl Ud
PLATES GRIP
TCLL 35.0
Plates Increase 1.15
TC 0.75
Vert(LL)
-0.36 14-15 >999 240
MT20 169/123
(Roof Snow=35.0)
Lumber Increase 1.15
BC 0.97
Vert(TL)
-0.58 14-15 >839 180
TCDL 8.0
Rep Stress Incr NO
WB 0.68
Horz(TL)
0.15 9 n/a n/a
BCLL 0.0
Code IRC2003ITP12002
(Matrix)
Weight: 454lb
BCDL 8.0
LUMBER
TOP CHORD 2 X 4 SPF 165OF 1.5E
BRACING
TOP CHORD Structural wood sheathing directly applied or 4-9-5 oc purtins, except end
BOT CHORD 2 X 6 DF No.2
WEBS 2 X 4 SPF-S Stud/Std *Except*
verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
W2 2 X 4 SPF 165OF 1.5E, W2 2 X 4 SPF 1650F 1.5E
WEBS
1 Row at midpt 2-17
W2 2 X 4 SPF 1650F 1.5E, W2 2 X 4 SPF 1650F 1.5E
W2 2 X 4 SPF 165OF 1.5E
REACTIONS (lb/size) 17=5029/0-3-0, 9=4921/0-5-8
Max Horz 17=-244(LC 8)
Max Upliftl 7=-1 005(LC 5), 9=-859(LC 5)
Max Grav 17=5468(LC 2), 9=4921(LC 1)
FORCES (lb) - Maximum Compression/Maximum Tension
TOP CHORD 1-17=-215/5, 1-2=-66/9, 2-3=-8502/1579, 3-4=-8502/1579, 4-5=-850211579, 5-6=-8827/1686, 6-7=-8843/1686,
7-8=-7324/1448,8-9=-7205/1344,9-10=01205
BOT CHORD 16-17=-861/5370, 15-16=-861/5370, 14-15=-1674/9653, 13-14=-1674/9653, 12-13=-1036/5886, 11-12=-991/5570,
9-11=-991/5570
-16=-474/1446, 2-15=-783/4174, 3-15=-437/4, 5-15=-1534/308, 5-14=-404/1303, 5-13=-1112/170,
WEBS 2-17=-7069/1309, 2
6-13=-521/15, 7-13=-686/3956, 7-12=-411/1643, 8-12=-418/482, 8-11=-304/145
NOTES
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2 X 4 - 1 row at 0-9-0 oc.
Bottom chords connected as follows: 2 X 6 - 2 rows at 0-9-0 oc.
Webs connected as follows: 2 X 4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Wind: ASCE 7-98; 90mph; h=25ft; TCDL=4.8psf; BCDL=4.8psf; Category 11; Exp C; enclosed; MW FRS interior zone; Lumber DOL=1.33
plate grip DOL=1.33.
4) TCLL: ASCE 7-98; Pf=35.0 psf (flat roof snow); Exp C; Fully Exp.; L= 45-0-0
5) Unbalanced snow loads have been considered for this design.
6) This truss has been designed for greater of min roof live load of 20.0 psf or 2.00 times flat roof load of 35.0 psf on overhangs non -concurrent
with other live loads.
7) Provide adequate drainage to prevent water ponding.
8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1005 lb uplift at joint 17 and 859 lb uplift at joint
9.
10) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
11) Girder carries hip end with 8-0-0 right side setback, 0-0-0 left side setback, and 8-0-0 end setback.
12) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 884 lb down and 329 lb up at 33-2-10
Confs ~. The design/selection of such connection device(s) is the responsibility of others.
job
Truss
Truss Type
Qty
Ply
FILLMORElCANYON VIEW 99
0811022
F1
ROOF TRUSS
2
Job Reference (optional)
•s wnn
- IA... nn nM7 RA:T..L Iw.1..nkr:ee. P- Er; cnn n7 in -A AR 9M7 Pnna 7
STOCK CUMNUNtN I s-I1%10ano raus, Iv 00WO. t,LMT %.J.
LOAD CASE(S) Standard
1) Snow: Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: 1-7=-43(F=43), 7-10=-86,12-17=-200(F=-184), 9-12=-16
Concentrated Loads (Ib)
Vert: 12=-884(F)
Job
Truss
Truss Type
Qty
Piy
FILLMORE/CANYON VIEW 9/7
0811022
F10
ROOF TRUSS
1
1
Job Reference(optional)
C.: Cnn A7 1A•AR•AQ ,3M7 Donal
J I Vl.l\ IrVMYVIVCry 1 J-Ir, iud7N raim, no ur v. , vv I W.
5-3-10 10-6-3 + 15-8-12 20-5-11 25-2-10 30-5-3 35-7-12 41-2-10 03-2119
5-3-10 5-2-9 5-2-9 4-8-15 4-8-15 5-2-9 5-2-9 5-6-14 2-0-0
Scale = 110.5
3x4 II 6x6 =
5x8 4-
5x8 =
3x4 = US
Sx8 =
3x4 =
4-10-12 7-10-15 15-8-12 25-2-10 33-0-7 41-2-10
4-10-12 3-0-3 7-9-13 9-5-14 7-9-13 8-2-3
LOADING (psf)
SPACING 2-0-0
CSI
DEFL in (loc) Vdefl Ud
PLATES GRIP
TCLL 35.0
Plates Increase 1.15
TC 0.78
Vert(LL) -0.16 12-13 >999 240
MT20 169/123
(Roof Snow=35.0)
Lumber Increase 1.15
BC 0.49
Vert(TL) .0.32 13-14 >999 180
TCDL 8.0
Rep Stress Incr YES
WB 0.98
Horz(TL) 0.10 10 n/a n/a
BCLL 0.0
Code IRC2003/TPI2002
(Matrix)
Weight: 2191b
LUMBER
TOP CHORD 2 X 4 SPF 165OF 1.5E
BOT CHORD 2 X 4 SPF 165OF 1.5E
WEBS 2 X 4 SPF 1650F 1.5E 'Except-
W2 2 X 4 SPF-S Stud/Std, W2 2 X 4 SPF-S Stud/Std
W 1 2 X 4 SPF-S Stud/Std
WEDGE
Left: 2 X 6 DF No.2, Right: 2 X 8 DF 195OF 1.7E
REACTIONS (lb/size) 10=203110-5-8, 1=1221Mechanical, 16=2216/0-5-8
Max Horz 1=-328(LC 5)
Max Up11ft10=-186(LC 8). 1=-134(LC 3), 16=-149(LC 7)
Max Grav10=2783(LC 3), 1=305(LC 2), 16=2693(LC 2)
BRACING
TOP CHORD Structural wood sheathing directly applied or 3-3-10 oc purlins.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 1 Row at midpt 3-15, 5-14, 5-13. 7-13, 2-16
FORCES (lb) - Maximum Compresslon/Maximum Tension
TOP CHORD 1-2=-226/329, 2-3=-14021130, 3-4=-1891/167, 4-5=-13481164, 5-6=-17031195, 6-7=-2334/192, 7-8=-2932/174, 8-9=-3141/147,
9-10=-3535/133, 10-11=0/197
BOT CHORD 1-16=-231/225, 15-16=-145/237, 14-15=-138/1291, 13-14=-64/1599, 12-13=0/2181, 10-12=0/2599
WEBS 2-15=0/1326, 3-15=-1124/35, 3-14=-56/575, 4-14=-42/573, 5-14=-970/177, 5-13=-391/290, 6-13=-29/619, 7-13=-884/178,
7-12=-29/542, 9-12=-468/133, 2-16=-2548/159
NOTES
1) Wind: ASCE 7-98; 90mph; h=25ft; TCDL=4.8psf; BCDL=4.8psf; Category II; Exp C; enclosed; MW FRS interior zone; Lumber DOL=1.33
plate grip DOL=1.33.
2) TCLL: ASCE 7-98; Pf--35.0 psf (flat roof snow); Exp C; Fully Exp.
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 35.0 psf on overhangs non -concurrent
with other live loads.
5) Provide adequate drainage to prevent water ponding.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) This truss requires plate inspection per the Tooth Count Method when this truss is chosen for quality assurance inspection.
8) Refer to girders) for truss to truss connections.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 186 lb uplift at joint 10, 134 lb uplift at joint 1
and 149 lb uplift at joint 16.
10) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSVTPI 1.
LOAD CASE(S) Standard
Truss
1022 J F11 I ROOF TRUSS
Idaho
7.000 s May 29
10:46:51
2 0 0,2 2 12�2 0 10 7-0 16-0-0 20-8-15 25-5-14 30-8-7 35-11-0 41-5-14 43-5-14
2-0-0 2-2-12 2-11-4 5-5-0 5-5-0 4-8-15 4-8-15 5-2-9 5-2-9 5-6-14 2-0-0
Scale = 1:74.0
5x8 i
30 = 5x8 l�
2-2-12 5-2-0 10-7-0 16-0-0 25-5-14 33-3-11 41-5-14
2-2-12 2-11-4 5-5-0 5-5-0 9-5-14 7-9-13 8-2-3
LOADING (psf) SPACING 2-0-0 CSI
TCLL 35.0 Plates Increase 1.15 TC 0.78
(Roof Snow=35.0) Lumber Increase 1.15 BC 0.49
TCDL 8.0 Rep Stress Incr YES WB 0.80
BCLL 0.0 Code IRC2003/TP12002 (Matrix)
BCDL 8.0
LUMBER
TOP CHORD 2 X 4 SPF 1650F 1.5E
BOT CHORD 2 X 4 SPF 165OF 1.5E
WEBS 2 X 4 SPF 1650F 1.5E -Except-
W 1 2 X 4 SPF-S Stud/Std, W 2 2 X 4 SPF-S Stud/Std
W 3 2 X 4 SPF-S Stud/Std, W 112 X 4 SPF-S Stud/Std
WEDGE
Right: 2 X 8 DF 1950F 1.7E
REACTIONS (lb/size) 20=341/0-5-8, 19=2241/0-5-8, 13=2006/0-5-8
Max Horz 20=-301(LC 5)
Max Uplift20=-264(LC 3), 19=-119(LC 7), 13=-185(LC 8)
Max Grav20=747(LC 2), 19=2620(LC 2), 13=2771(LC 3)
DEFL
in (loc)
I/deft
Ud
PLATES GRIP
Vert(LL)
-0.1615-16
>999
240
MT20 169/123
Vert(TL)
-0.3716-17
>999
180
Horz(TL)
0.09 13
n/a
n/a
Weight: 227 lb
BRACING
TOP CHORD Structural wood sheathing directly applied or 3-3-12 oc purlins.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 1 Row at midpt 5-19, 8-17, 8-16, 10-16
FORCES (Ib) - Maximum Compression/Maximum Tension
TOP CHORD 1-2=0/191, 2-3=-229/958, 3-4=-106/408, 4-5=-93/538, 5-6=-1650/115, 6-7=-1810/164, 7-8=-1272/157, 8-9=-1689/193,
9-10=-2315/190, 10-11=-2913/172, 11-12=-3122/145, 12-13=-3516/131, 13-14=0/197
BOT CHORD 2-20=-710/284, 19-20=-710/350, 18-19=-330/254, 17-18=-144/1156, 16-17=-68/1579, 15-16=0/2166, 13-15=0/2584
WEBS 3-20=-786/260, 3-19=-255/472, 5-19=-2759/199, 5-18=-30/1804, 6-18=-996/64, 6-17=-76/603, 7-17=-39/556, 8-17=-986/179,
8-16=-3491305, 9-16=-27/599, 10-16=-884/178, 10-15=-30/541, 12-15=-469/133
NOTES
1) Wind: ASCE 7-98; 90mph; h=25ft; TCDL=4.Bpsf; BCDL=4.8psf; Category Il; Exp C; enclosed; MWFRS interior zone; Lumber DOL=1.33
plate grip DOL=1.33.
2) TCLL: ASCE 7-98; Pf=35.0 psf (flat roof snow); Exp C; Fully Exp.
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 35.0 psf on overhangs non -concurrent
with other live loads.
5) Provide adequate drainage to prevent water ponding.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) This truss requires plate Inspection per the Tooth Count Method when this truss is chosen for quality assurance inspection.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 264 lb uplift at joint 20, 119 lb uplift at joint 19
and 185 lb uplift at joint 13.
9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSIITPI 1.
LOAD CASE(S) Standard
Job
Truss
Truss Type
Qty
Pty
FILLMORE/CANYON VIEW 9/7
0811022
F12
ROOF TRUSS
1
1
,lob Reference banal
_ hArr_I. 6..I....M:— i— Ei Cnn n7 in-AIZ A OM7 P7na 1
STOCK COMPONENTS -IF, Idaho Falls, ID 83403, CLAY G.
-2-0-0 2-2-12 5-2-0 10-7-0 16-0-0 20-8-15 25-5-14 30-8-7 35-11-0 41-5-14
2-0-0 2-2-12 2-11-4 5-5-0 5-5-0 4-8-15 4-8-15 5-2-9 5-2-9 5-6-14
scale = 1:72.0
5x8 �i
3A = 5x8
1.50 11 US = 3xa = axa —---
2-2-12 5-2-0 10-7-0 16-0-0 25-5-14 33-3-11 41-5-14
2-2-12 2-11-4 5-5-0 5-5-0 9-5-14 7-9-13 8-2-3
LOADING (psf) SPACING 2-0-0 CSI
TCLL 35.0 Plates Increase 1.15 TC 0.64
(Roof Snow=35.0) Lumber Increase 1.15 BC 0.66
TCDL 8.0 Rep Stress Incr YES WB 0.80
BCLL 0.0 Code IRC2003/TP12002 (Matrix)
BCDL 8.0
LUMBER
TOP CHORD 2 X 4 SPF 165OF 1.5E
BOT CHORD 2 X 4 SPF 1650F 1.5E
WEBS 2 X 4 SPF 1650F 1.5E 'Except'
W 12 X 4 SPFS Stud/Std, W 2 2 X 4 SPF-S Stud/Std
W3 2 X 4 SPF-S Stud/Std, W 112 X 4 SPF-S Stud/Std
WEDGE
Right: 2 X 8 DF 1950E 1.7E
REACTIONS (lb/size) 19=335/0-5-8, 18=2254/0-5-8, 13=1799/0-5-8
Max Horz 19=328(LC 6)
Max Upliftl9=-273(LC 3),18=-128(LC 7), 13=-95(LC 8)
Max Grav 19=746(LC 2). 18=2622(LC 2), 13=2453(LC 3)
DEFL
in (loc)
l/defl
Ud
PLATES GRIP
Vert(LL)
-0,1713-14
>999
240
MT20 169/123
Vert(TL)
-0.37 15-16
>999
180
Horz(TL)
0.10 13
n/a
Na
Weight: 225 lb
BRACING
TOP CHORD Structural wood sheathing directly applied or 2-11-2 oc purlins.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 1 Row at midpt 5-18, 8-16, 8-15, 10-15
FORCES (Ib) - Maximum Compression/Maximum Tension
TOP CHORD 1-2=0/191, 2-3=-229/958, 3-4=-113/417, 4-5=-100/539, 5-6=-1650/106, 6-7=-1811/162, 7-8=-1273/156, 8-9=-1703/197,
9-10=-2332/193, 10-11=-2980/200, 11-12=-3196/173, 12-13=-3586/156
BOT CHORD 2-19=-710/285, 18-19=-710/325, 17-18=-337/237, 16-17=-169/1156, 15-16=-96/1590, 14-15=0/2197, 13-14=-51/2662
WEBS 3-19=-785/269, 3-18=-263/470, 5-18=-2761/205, 5-17=-34/1806, 6-17=-997/67, 6-16=-79/610, 7-16=-38/561, 8-16=-995/180,
8-15=-348/316, 9-15=-27/605, 10-15=-914/191, 10-14=-60/615, 12-14=-513/152
NOTES
1) Wind: ASCE 7-98; 90mph; h=25ft; TCDL=4.8psf; BCDL=4.8psf; Category 11; Exp C; enclosed; MWFRS interior zone; Lumber DOL=1.33
plate grip DOL=1.33.
2) TCLL: ASCE 7-98; Pf=35.0 psf (flat roof snow); Exp C; Fully Exp.
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 35.0 psf on overhangs non -concurrent
with other live loads.
5) Provide adequate drainage to prevent water ponding.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live toads.
7) This truss requires plate inspection per the Tooth Count Method when this truss is chosen for quality assurance inspection.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 273 lb uplift at joint 19, 128 lb uplift at joint 18
and 95 lb uplift at joint 13.
9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
Truss
Truss Type
Qty
Ply
FILLMORE/CANYON VIEW 9/7
Q811022
F13
ROOF TRUSS
2
1
Job Reference(optional)
7 nnn
& KA— 0301,7M7 Mi-rak Inds iclriAc_ Inc_ Fri San 07 10:46:55 2007 Pane 1
5I LAiK L:UwUN=N 1 J-Ir, auenu rcub, iu w—t—, van, . .
6-7-14 12-11-6 19-6-6
6-7-14 6-3-8 6-7-0
3x6
4
8x10 7� 7 6 5
1.5x4 II 4x4 = US =
6-7-14 12-11-6 19-6-6
6-7-14 6-3-8 6-7-0
LOADING (psf)
SPACING 2-0-0
CSI
DEFL
in (loc)
Vdefl
Ud
TCLL 35.0
Plates Increase 1.15
TC 0.76
Vert(LL)
-0.13 1-7
>999
240
(Roof Snow=35.0)
Lumber Increase 1.15
BC 0.64
Vert(TL)
-0,21 1-7
>999
180
TCDL 8.0
Rep Stress lncr YES
WB 0.64
Horz(TL)
0.04 5
n/a
n/a
BCLL 0.0
Code IRC2003/TPI2002
(Matrix)
acne 8.0
LUMBER
TOP CHORD 2 X 4 SPF 165OF 1.5E
BOT CHORD 2 X 4 SPF 1650E 1.5E
WEBS 2 X 4 SPF 165OF 1.5E 'Except'
W5 2 X 6 DF No. 2, W 12 X 4 SPF-S Stud/Std
WEDGE
Left: 2 X 8 DF 1950F 1.7E
REACTIONS (lb/size) 5=973/0-5-8.1=973/Mechanical
Max Horz 1=421(LC 7)
Max Uplift5=-254(LC 7)
Max Grav 5= 141 8(LC 2). 1=1418(LC 2)
FORCES (Ib) - Maximum Compression/Maximum Tension
TOP CHORD 1-2=-1912/0, 2-3=-1080/0, 3-4=-302/203, 4-5=-379/103
BOT CHORD 1-7=-244/1313, 6-7=-244/1311, 5-6=-119/663
WEBS 2-7=0/250, 2-6=-837/162, 3-6=-30/598, 3-5=-1160/209
Scale = 111.0
PLATES GRIP
MT20 169/123
Weight: 120 lb,
BRACING
TOP CHORD Structural wood sheathing directly applied or 3-8-6 oc purlins, except end
verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 4-5, 3-5
NOTES
1) Wind: ASCE 7-98; 90mph; h=25ft; TCDL=4.8psf; BCDL=4.8psf; Category It Exp C; enclosed; MW FRS interior zone; Lumber DOL=1.33
plate grip OOL=1.33.
2) TCLL: ASCE 7-98; Pf=35.0 psf (flat roof snow); Exp C; Fully Exp.
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 254 lb, uplift at joint 5.
7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSVTPI 1.
LOAD CASE(S) Standard
0811022 1F14
, Idaho Falls, ID 83403.
ROOF TRUSS
s May 29 2007 MTek Industries, Inc. Fri Sep 0710:46:57 2007 Page 1
6-2-14 12-1-7 18-0-0 19-6-6
6-2-14 5-10-9 5-10-9 1-6-6
600 MT18H,i SC21e = 1 713
5x6 =
4 5
5x8 = 6 7 6
4x4 = U4 11
6x8 =
9-2-3 18-0-0 19-6-0
9-2-3 8-9-13 1-6-6
LOADING (psf)
SPACING 2-0-0
CSI
DEFL
in (loc)
Vdefl
Ud
TCLL 35.0
Plates Increase 1.15
TC 0.71
Vert(LL)
-0.18 1-8
>999
240
(Roof Snow=35.0)
Lumber Increase 1.15
BC 0.55
Vert(TL)
-0.37 1-8
>621
180
TCDL 8.0
Rep Stress Incr YES
WB 0.59
Horz(TL)
0.03 6
n/a
nla
BCLL 0.0
Code IRC2003ITP12002
(Matrix)
LUMBER
TOP CHORD 2 X 4 SPF 165OF 1.5E
BOT CHORD 2 X 4 SPF 165OF 1.5E
WEBS 2 X 4 SPF 1650F 1.5E -Except'
W 12 X 4 SPF-S Stud/Std
REACTIONS (lb/size) 6=985/0-5-8.1=985/Mechanical
Max Horz 1=394(LC 7)
Max Uplift6=-219(LC 7)
MaxGrav6=1280(LC 2), 1=1431(LC 2)
FORCES (lb) - Maximum Compression/Maximum Tension
TOP CHORD 1-2=-192510, 2-3=-1483/0, 3-4=-420/49, 4-5=-135/21, 5-6=-1221/161
BOT CHORD 1-8=-258/1357, 7-8=-139/746, 6-7=-1/7
WEBS 2-8=-672/178, 3-8=-70/804, 3-7=-11061214. 4-7=-443/140, 5-7=-206/1383
PLATES GRIP
MT20 169/123
MT18H 197/144
Weight: 123 ib
BRACING
TOP CHORD Structural wood sheathing directly applied or 3-10-0 oc purlins, except
end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 5-6. 3-7, 4-7, 5-7
NOTES
1) Wind: ASCE 7-98; 90mph; h=25ft; TCDL=4.8psf; BCDL=4.8psf; Category II; Exp C; enclosed; MW FRS interior zone; Lumber DOL=1.33
plate grip DOL=1.33.
2) TCLL: ASCE 7-98; Pf=35.0 psf (flat roof snow); Exp C; Fully Exp.
3) Unbalanced snow loads have been considered for this design.
4) Provide adequate drainage to prevent water ponding.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live toads.
6) All plates are MT20 plates unless otherwise indicated.
7) Refer to girder(s) for truss to truss connections.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 219 lb uplift at joint 6.
9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
5-6-14 10-9-7 16-0-0 19-6-6
5-6-14 5-2-9 5-2-9 axe 3-6-6 scale = 1.60.3
6z6 =
5 6
5x8 ::: 9 8 7
40 = 6x6 = 1.50 11
8-2-3 16-0-0 19-6-6
8-2-3 7-9-13 3-6-6
LOADING (psf) SPACING 2-0-0
CSI
TCLL 35.0 Plates Increase 1.15
TC 0.56
(Roof Snow=35.0) Lumber Increase 1.15
BC 0.48
TCDL 8.0 Rep Stress Incr YES
WB 0.42
BCLL 0.0 Code IRC2003/TP12002
(Matrix)
BCDL 8.0
LUMBER
TOP CHORD 2 X 4 SPF 165OF 1.5E
BOT CHORD 2 X 4 SPF 165OF 1.5E
WEBS 2 X 4 SPF 165OF 1.5E 'Except'
W 12 X 4 SPF-S Stud/Std
REACTIONS (lb/size) 7=985/0-5-8, 1=985/Mechanical
Max Horz 1=350(LC 7)
Max Uplift7=-171(LC 7)
MaxGrav7=1076(LC 2), 1=1402(LC 2)
DEFL
in
(loc)
VdeFl
Ud
PLATES GRIP
Vert(LL)
-0.13
1-9
>999
240
MT20 169/123
Vert(TL)
-0.26
1-9
>903
180
Horz(TL)
0.03
7
n/a
n/a
Weight: 115 lb
BRACING
TOP CHORD Structural wood sheathing directly applied or 4-3-8 oc purlins, except end
verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 6-7. 4-8. 5-8
FORCES (lb) - Maximum CompressionlMaximum Tension
TOP CHORD 1-2=-1918/0, 2-3=-1525/0, 3-4=-1146/14, 4-5=-591/7, 5-6=-293/47, 6-7=-1057/173
BOT CHORD 1-9=-256/1368, 8-9=-1521834, 7-8=-1/6
WEBS 2-9=-591/158, 4-9=-601703, 4-8=-981/190, 5-8=-225/82, 6-8=-18011128
NOTES
f; Category 11; Exp C; enclosed; MW FRS interior zone; Lumber DOL=1.33
1) Wind: ASCE 7-98; 90mph; h=25ft; TCDL=4.8psf; BCDL=4.8ps
plate grip DOL=1.33.
2) TCLL: ASCE 7-98; Pf=35.0 psf (flat roof snow); Exp C; Fully Exp.
3) Unbalanced snow loads have been considered for this design.
4) Provide adequate drainage to prevent water ponding.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 171 lb uplift at joint 7.
8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSt/TPI 1.
LOAD CASE(S) Standard
Job I M,
Q811022 F16
, Idaho
ROOF TRUSS I 1 I 1
s May 29 2007 MTek Industries, Inc. Fri Sep 0710:46:59 2007 Page 1
7-2-3 14-0-0 i 19-6-6
7-2-3 6-9-13 4x8 5-6-6
Scale = 1:53.2
�i
4x5
3 4
5x8 y 7 6 5
1.50 II 4x8 = 2x4 II
7-2-3 14-0-0 19-6-6
7-2-3 6-9-13 5-6-6
LOADING (psf)
SPACING 2-0-0
CSI
DEFL
in (loc)
I/defl
Ud
TCLL 35.0
Plates Increase 1.15
TC 0.85
Vert(LL)
-0.14 1-7
>999
240
(Roof Snow=35.0)
Lumber Increase 1.15
BC 0.58
Vert(TL)
-0.24 1-7
>952
180
TCDL 8.0
Rep Stress Incr YES
WB 0.26
Horz(TL)
0.03 5
n/a
rVa
BCLL 0.0
Code IRC2003/TP12002
(Matrix)
RCDL &0
LUMBER
TOP CHORD 2 X 4 SPF 1650F 1.5E
BOT CHORD 2 X 4 SPF 1650F 1.5E
WEBS 2 X 4 SPF 165OF 1.5E *Except*
W 12 X 4 SPF-S Stud/Std
REACTIONS (lb/size) 1=985/Mechanical, 5=985/0-5-8
Max Horz 1=307(LC 7)
Max Upliftl=-3(LC 7). 5=-129(LC 7)
Max Grav 1=1160(LC 2), 5=985(LC 1)
FORCES (lb) - Maximum Compression/Maximum Tension
TOP CHORD 1-2=-1535/0, 2-3=-727/22, 3-4=-383/69, 4-5=-940/148
BOT CHORD 1-7=-213/1050, 6-7=-213/1050, 5-6=-3/18
WEBS 2-7=0/284, 2-6=-854/180, 3-6=-258/102, 4-6=-158/846
PLATES GRIP
MT20 169/123
Weight: 100 lb
BRACING
TOP CHORD Structural wood sheathing directly applied or 3-1-0 oc purlins, except end
verticals.
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 1 Row at midpt 4-5, 2-6, 3-6
NOTES
1) Wind: ASCE 7-98; 90mph; h=25ft; TCDL=4.8psf; BCDL=4.8psf; Category 11; Exp C; enclosed; MWFRS interior zone; Lumber DOL=1.33
plate grip DOL=1.33.
2) TCLL: ASCE 7-98; Pf=35.0 psf (flat roof snow); Exp C; Sheltered
3) Unbalanced snow loads have been considered for this design.
4) Provide adequate drainage to prevent water ponding.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) This truss requires plate inspection per the Tooth Count Method when this truss is chosen for quality assurance inspection.
7) Refer to girder(s) for truss to truss connections.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 3 lb uplift at joint 1 and 129 lb uplift at joint 5.
9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSIITPI 1.
LOAD CASE(S) Standard
0811022 1 F17 I ROOF TRUSS
1 1 1
Falls, ID 83403, CLAY G. 7.000 s May 29 2007 MTek
6-2-3 12-0-0 15-7-7 19-6-6
6-2-3 5-9-13 3-7-7 3-10-15
4x8 �,
4x4 = 3x4 II
3 4 5
1.50 II 4x8 = 40 =
6-2-3 12-0-0 19-6-6
6-2-3 5-9-13 7-6-6
Plate Offsets MY): [1:0-1-8 Edae1 [3.0-4-8 0-1-121
10:47:00 2007 Pane 1
Scale = 1:45.9
LOADING (psf)
SPACING
2-0-0
CSI
DEFL in
(loc) Vdefl Ud
PLATES GRIP
TCLL 35.0
Plates Increase
1.15
TC 0.74
Vert(LL) -0.10
1-8 >999 240
MT20 169/123
(Roof Snow=35.0)
Lumber Increase
1.15
BC 0.55
Vert(TL) -0.17
1-8 >999 180
TCDL 8.0
Rep Stress Incr
YES
WB 0.56
Horz(TL) 0.03
6 n/a n/a
BCLL 0.0
Code IRC20031TP12002
(Matrix)
Weight: 102lb
BCDL 8.0
LUMBER
TOP CHORD 2 X 4 SPF 165OF 1.5E
BRACING
TOP CHORD
Structural wood sheathing directly applied or 4-4-5 oc purtins, except end
BOT CHORD 2 X 4 SPF 165OF 1.5E
verticals.
WEBS 2 X 4 SPF 165OF 1.5E'ExcepV
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
W 12 X 4 SPF-S Stud/Std
WEBS
1 Row at midpt 5.6, 3-7. 4-6
REACTIONS (lb/size) 1=985/Mechanical, 6=985/0-5-8
Max Horz 1=263(LC 7)
Max Upliftl=-18(LC 7), 6=-106(LC 6)
Max Gravl=1272(LC 2), 6=1006(LC 3)
FORCES (lb) - Maximum Compression/Maximum Tension
TOP CHORD 1-2=-1715/23, 2-3=-918/42, 3-4=-527/78, 4-5=-13/0, 5-6=-216/34
BOT CHORD 1-8=-203/1187, 7-8=-20311187, 6-7=-42/333
WEBS 2-8=0/225, 2-7=-839/158, 3-7=-51/126, 4-7=-99/716, 4-6=-839/116
NOTES
1) Wind: ASCE 7-98; 90mph; h=25ft; TCDL=4.8psf; BCDL=4.8psf; Category II; Exp C; enclosed; MWFRS interior zone; Lumber DOL=1.33
plate grip DOL=1.33.
2) TCLL: ASCE 7-98; Pf=35.0 psf (flat roof snow); Exp C; Fully Exp.
3) Unbalanced snow loads have been considered for this design.
4) Provide adequate drainage to prevent water ponding.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 18 lb uplift at joint 1 and 106 lb uplift at joint 6.
8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
Truss
Truss Type
Qty
Ply
FILLMORE/CANYON VIEW 917
0811022
F18
ROOF TRUSS
1
1
,lob Reference (optional)
7 nnn.
Mo.. W Irv» kATak Inrfimtoiws. Inc. Fri Sen 07 10:47:01 2007 Page 1
J I CA.FI L0UWJ "VrvGv i J-Ir, wOiru FORD, 1v awrr...., vv . .+•
5-2-3 10-0-0 14-7-7 19-6-6
5-2-3 4-9-13 4-7-7 4-10-15
Scale = 1:39.0
5x6 =
30 =
4
30 11
5
1.50 II 300 = 3x8 =
5-2-3 10-0-0 19-6-6
5-2-3 4-9-13 9-6-6
LOADING (psf)
SPACING 2-0-0
CSI
DEFL in (loc) Vdefl Ud
PLATES GRIP
TCLL 35•0
Plates Increase 1.15
TC 0.49
Vert(LL) -0.16 6-7 >999 240
MT20 1691123
(Roof Snow=35.0)
Lumber Increase 1.15
BC 0.46
Vert(TL) -0.36 6-7 >634 180
TCDL 8.0
Rep Stress Incr YES
WB 0.70
Horz(TL) 0.02 6 n/a n/a
BCLL 0.0
Code IRC2003/TPI2002
(Matrix)
Weight: 93lb
LUMBER
TOP CHORD 2 X 4 SPF 1650F 1.5E
BOT CHORD 2 X 4 SPF 165OF 1.5E
WEBS 2 X 4 SPF 165OF 1.5E *Except*
W 12 X 4 SPF-S Stud/Std, W 2 2 X 4 SPF-S Stud/Std
REACTIONS (lb/size) 1=977/0-5-8, 6=977/0-5-8
Max Horz 1=220(LC 7)
Max Upliftl=-26(LC 7). 6=-103(LC 6)
Max Grav 1=1156(LC 2), 6=1133(LC 3)
FORCES (lb) - Maximum Compression/Maximum Tension
TOP CHORD 1-2=-1560/40, 2-3=-936/52, 3-4=-645/77, 4-5=-30/0, 5-6=-278/45
BOT CHORD 1-8=-186/1079, 7-8=-186/1079, 6-7=-62/519
WEBS 2-8=0/144. 2-7=-641/138, 3-7=01183. 4-7=-56/519, 4-6=-922/126
BRACING
TOP CHORD Structural wood sheathing directly applied or 5-1-13 oc purlins, except
end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 5-6. 4-6
NOTES
1) Wind: ASCE 7-98; 90mph; h=25ft; TCDL=4.8psf; BCDL=4.8psf; Category II; Exp C; enclosed, MWFRS interior zone; Lumber DOL=1.33
plate grip DOL=1.33.
2) TCLL: ASCE 7-98; Pf=35.0 psf (flat roof snow); Exp C; Fully Exp.
3) Unbalanced snow loads have been considered for this design.
4) Provide adequate drainage to prevent water ponding.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 26 lb uplift at joint 1 and 103 lb uplift at joint 6.
7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Truss
F19
Truss Type
ROOF TRUSS
Qty
1
Ply
2
- nnn
FILLMORE/CANYON VIEW 9/7
Job Reference Donal
� Rk,, en'5M7 KA;Tdr Mrl, Mtriac Inr_ Fri Rpm 07 10*47:01 2007 Pace 1
Job
Q811022
STOCK COMPONENTS -IF, Idaho Falls, Ill U34W, ULAY U.
-2-0-0 4-3-8 8-0-0 13-7-7 19-6-6
2-0-0 4-3-8 3-8-8 5-7-7 5-10-15
Scale = 1:30 4
5x6 =
1.50 It SX5 _
4-3-8 8-0-0 13-7-7 19-6-6
4-3-8 3-8-8 5-7-7 5-10-15
LOADING (psf)
SPACING 2-0-0
CSI
TCLL 35.0
Plates Increase 1.15
TC 0.60
(Roof Snow=35.0)
Lumber Increase 1.15
BC 0.43
TCDL 8.0
Rep Stress Incr NO
W B 0.62
BCLL 0.0
Code IRC2003ITP12002
(Matrix)
BCDL 8.0
LUMBER
TOP CHORD 2 X 4 SPF 165OF 1.5E
BOT CHORD 2 X 6 DF No.2
WEBS 2 X 4 SPF-S Stud/Std 'Except-
W4 2 X 4 SPF 165OF 1.5E, W4 2 X 4 SPF 1650E 1.5E
REACTIONS (lb/size) 7=2458/0-5-8, 2=2215/0-5-8
Max Horz2=244(LC 7)
Max Uplift7=-504(LC 6). 2=-403(LC 7)
Max Grav 7=2731 (LC 3), 2=2381(LC 2)
DEFL in (loc) I/deft Ud
Vert(LL) -0.06 8-9 >999 240
Vert(TL) -0.10 8-9 >999 180
Horz(TL) 0.02 7 n/a n/a
PLATES GRIP
MT20 169/123
Weight: 220 lb
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purtins, except end
verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 1 Row at midpt 6-7
FORCES (lb) - Maximum Compression/Maximum Tension
TOP CHORD 1-2=0/205, 2-3=-2917/480, 3-4=-2762/547, 4-5=-2027/387, 5-6=-2024/386, 6-7=-2242/392
BOT CHORD 2-10=-454/2201, 9-10=-454/2201, 8-9=-450/2137, 7-8=-6/49
WEBS 3-10=-143/109, 3-9=-234/157, 4-9=-384/1689, 4-8=-554/129, 5-8=-577/195, 6-8=-542/2815
NOTES
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2 X 4 -1 row at 0-9-0 oc.
Bottom chords connected as follows: 2 X 6 - 2 rows at 0-9-0 oc.
Webs connected as follows: 2 X 4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Wind: ASCE 7-98; 90mph; h=25ft; TCDL=4.8psf; BCDL=4.8psf; Category II; Exp C; enclosed; MWFRS interior zone; Lumber DOL=1.33
plate grip DOL=1.33.
4) TCLL: ASCE 7-98; Pf=35.0 psf (flat roof snow); Exp C; Fully Exp.
5) Unbalanced snow loads have been considered for this design.
6) This truss has been designed for greater of min roof live load of 20.0 psf or 2.00 times flat roof load of 35.0 psf on overhangs non -concurrent
with other live loads.
7) Provide adequate drainage to prevent water ponding.
8) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 504 lb uplift at joint 7 and 403 lb uplift at joint 2.
10) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
11) Girder carries hip end with 0-0-0 right side setback, 8-0-0 left side setback, and 8-0-0 end setback.
12) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 884 lb down and 241 lb up at 8-0-0 on
bottom chord. The design/selection of such connection device(s) is the responsibility of others.
LOAD CASE(S) Standard
1) Snow: Lumber Increase=1.15, Plate Increase=1.15
Continued on page 2
Job
Truss
Truss Type
Qty
Ply
FILLMORE/CANYON VIEW W
Q811022
F19
ROOF TRUSS
1
2
Jab Reference (optional)
5 I cx;K GUMNUNI:N lb-tl% taaRO taus. IU MAW. 1AAT V.
LOAD CASE(S) Standard
Uniform Loads (plf)
Vert: 1-4=-86, 4-6=-43(F=43), 2-9=-16, 7-9=-200(F=-184)
Concentrated Loads (lb)
Vert: 9=-884(F)
I.wu s ivray ZW cwi iva i W% UIUwuiq, UK;. rn QtW w w.W .v 9 cwr rayc c
Job
Thus
Truss Type
Qty
Ply
FILLMORFJCANYON MEW SU
0811022
F2
ROOF TRUSS
1
1
Job Reference (optional)
a i wn L.vnvu-1 nv=ry i a-ir, imu W raus, iw or#uo, vL^ i %3.
0 ..,Pr -.... wr .,. ....-...- . .U- -
4-10-15 9-8-12 16-10-2 24-1-4 31-2-10 36-0-7 41-2-10 13-2-10
4-10-15 4-9-13 7-1-6 7-3-2 7-1-6 4-9-13 5-2-3 2-0-0
Scale = 1:71.6
Bx10 MT18H= 6x10 MT18H=
3x4 = 3A = 1.5x4 II
3 4 5 6 7
10x10 = 1.5x4 II 30 = Bx8 = Sx10 = 30 = 1.5x4 If 8x8 =
4-10-15 9-8-12 16-10-2 24-1-4 31-2-10 36-0-7 41-2-10
4-10-15 4-9-13 7-1-6 7-3-2 7-1-6 4-9-13 5-2-3
LOADING (psf)
SPACING 2-0-0
CSI
DEFL
in (loc) Vdefl Ud
PLATES GRIP
TCLL 35•0
Plates Increase 1.15
TC 0.97
Vert(LL)
-0.31 13-14 >999 240
MT20 169/123
(Roof Snow=35.0)
Lumber Increase 1.15
BC 0.83
Vert(TL)
-0.48 13-14 >999 180
MT18H 197/144
TCDL 8.0
Rep Stress Incr YES
WB 0.77
Horz(TL)
0.21 9 n/a n/a
BCLL 0.0
Code IRC2003/TPI2002
(Matrix)
Weight: 199lb
BCDL 8.0
LUMBER
BRACING
TOP CHORD 2 X 4 SPF 165OF 1.5E 'Except'
TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins.
T2 2 X 4 SPF 210OF 1.8E, T3 2 X 4 SPF 210OF 1.8E
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
BOT CHORD 2 X 4 SPF 1650F 1.5E
WEBS
1 Row at midpt 4-13
WEBS 2 X 4 SPF 165OF 1.5E 'Except
W 12 X 4 SPF-S Stud/Std, W 2 2 X 4 SPF-S Stud/Std
W 2 2 X 4 SPF-S Stud/Std, W 12 X 4 SPF-S Stud/Std
WEDGE
Left: 1.5 X 11.88 LSL Truss Grade, Right: 2 X 10 DF 1950F 1.7E
REACTIONS (lb/size) 9=2290/0-5-8.1=2080/Mechanical
Max Horz 1=-214(LC 5)
Max Uplift9=-178(LC 5). 1=-159(LC 6)
Max Grav9=3223(LC 3). 1=2902(LC 2)
FORCES (lb) - Maximum Compression/Maximum Tension
TOP CHORD 1-2=-4283/259, 2-3=-3737/293, 3-4=-3822/332, 4-5=-3806/330, 5-6=-3806/330, 6-7=-3830/335, 7-8=-3735/293,
8-9=-4247/254, 9-10=0/197
BOT CHORD 1-16=-303/3164, 15-16=-303/3164, 14-15=-252/2868, 13-14=-314/3817, 12-13=-113/2870, 11-12=-113/3151, 9-11=-113/3151
WEBS 2-16=0/162,2-15=-379/124,3-15=-18/343,3-14=-226/1765,4-14=-ll64/234,4-13=-168/179,6-13=-1033/190,
7-13=-229/1767, 7-12=-0/347, 8-12=-359/89, 8-11=-0f156
NOTES
1) Wind: ASCE 7-98; 90mph; h=25ft; TCDL=4.8psf; BCDL=4.8psf; Category II; Exp C; enclosed; MW FRS interior zone; Lumber DOL=1.33
plate grip DOL=1.33.
2) TCLL: ASCE 7-98; Pf=35.0 psf (flat roof snow); Exp C; Fully Exp.; L= 45-0-0 '
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 35.0 psf on overhangs non -concurrent
with other live loads.
5) Provide adequate drainage to prevent water ponding.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) All plates are MT20 plates unless otherwise indicated.
8) This truss requires plate inspection per the Tooth Count Method when this truss is chosen for quality assurance inspection.
9) Refer to girder(s) for truss to truss connections.
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 178 lb uplift at joint 9 and 159 Ib uplift at joint
1.
11) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Q811022
F3
ROOF TRUSS
1 I 1 I ,lob Reference (optional)
7.000 s Mav 29 2007 MTek Industries. Inc. Fri Sep 07 10:47:07 2007 Page 1
5-10-15 11-8-12 17-6-2 23-5-4 29-2-10 35-0-7 41-2-10 13-2-1 p
-,1
5-10-15 5-9-13 5-9-6 5-11-2 5-9-6 5-9-13 6-2-3 2-0-0
Scale = 1:71.6
Sx8 =
30 = 1.Sx4 II 5x8 =
3 4 5 6
10x10 = 1.50 II 30 = 6x6 = 6x8 = 30 = 1.5x4 II 8x8 =
5-10-15 11-8-12 -, 17-6-2 _� _-23-5-4 , __- 29-2-10 , 35-0-7 , 41-2-10 ,
5-10-15 5-9-13 5-9-6 5-11-2 5-9-6 5-9-13 6-2-3
LOADING (psf)
SPACING 2-0.0
CSI
DEFL in (loc) l/defl Ud
PLATES GRIP
TCLL 35.0
(Roof Snow=35.0)
Plates Increase 1.15
TC 0.91
Vert(LL) -0.26 12 >999 240
MT20 169/123
TCDL 8.0
Lumber Increase 1.15
BC 0.80
Vert(TL) -0.39 12-13 >999 180
BCLL 0.0
Rep Stress Incr YES
WB 0.91
Horz(TL) 0.19 8 n/a n/a
BCDL 8.0
Code IRC20031TPI2002
(Matrix)
Weight: 212lb
LUMBER BRACING
TOP CHORD 2 X 4 SPF 165OF 1.5E TOP CHORD Structural wood sheathing directly applied or 2-4-0 oc purlins.
BOT CHORD 2 X 4 SPF 165OF 1,5E BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2 X 4 SPF 1650F 1.5E'Except' WEBS 1 Row at midpt 4-13, 4-12, 5-12
W 12 X 4 SPF-S Stud/Std, W 2 2 X 4 SPF-S Stud/Std
W2 2 X 4 SPF-S Stud/Std, W 1 2 X 4 SPF-S Stud/Std
WEDGE
Left: 1.5 X 11.88 LSL Truss Grade, Right; 2 X 10 DF 195OF 1.7E
REACTIONS (lb/size) 8=2290/0-5-8, 1=2080/Mechanical
Max Horz 1=-251(LC 5)
Max Uplift8=- 1 66(LC 8), 1=-117(LC 6)
Max Grav8=3162(LC 3), 1=2840(LC 2)
FORCES (Ib) - Maximum Compression/Maximum Tension
TOP CHORD 1-2=-4179/198, 2-3=-3473/239, 3-4=-3061/242, 4-5=-3046/239, 5-6=-3063/243, 6-7=-3469/239, 7-8=-4148/194, 8-9=0/197
BOT CHORD 1-15=-284/3080, 14-15=-284/3080, 13-14=-212/2598, 12-13=-225/3057, 11-12=-75/2598, 10-11=-57/3067, 8-10=-57/3067
WEBS 2-15=0/222, 2-14=-616/148, 3-14=-36/477, 3-13=-198/1349, 4-13=-1041/223, 4-12=-214/219, 5-12=-853/160, 6-12=-200/1345
, 6-11=-22/482, 7-11=-598/118, 7-10=0/218
NOTES
1) Wind: ASCE 7-98; 90mph; h=25ft; TCDL=4.8psf, BCDL=4.8psf; Category II; Exp C; enclosed; MW FRS interior zone; Lumber DOL=1.33
plate grip DOL=1.33.
2) TCLL: ASCE 7-98; Pf=35.0 psf (flat roof snow); Exp C; Fully Exp.
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 35.0 psf on overhangs non -concurrent
with other live loads.
5) Provide adequate drainage to prevent water ponding.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) This truss requires plate inspection per the Tooth Count Method when this truss is chosen for quality assurance inspection.
8) Refer to girders) for truss to truss connections.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 166 Ib uplift at joint 8 and 117 lb uplift at joint 1.
10) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Jab Truss Truss Type
0811022 F4 I ROOF TRUSS
83403,
.000 s Mav 29 2007 MiTek Industries. Inc. Fri Sep 07 10:47:11
6-10-15 13-8-12 20-5-11 27-2-10 34-0-7 41-2-10 43-2-10
6-10-15 6-9-13 6-8-15 6-8-15 6-9-13 7-2-3 2-0-0
Scale = 1:71 4
6x10IUT18H=
1.5x4 II
6x10 MT18H=
1.5x4 II 5x6 = 08 = 5x6 = 1.5x4 I I exe =
6-10-15 13-8-12 20-5-11 27-2-10 34-0-7 41-2-10
6-10-15 6-9-13 6-8-15 6-8-15 6-9-13 7-2-3
LOADING (psf)
TCLL 35.0
(Roof Snow=35.0)
TCDL 8.0
BCLL 0.0
BCDL 8.0
SPACING 2-0.0
Plates Increase 1.15
Lumber Increase 1.15
Rep Stress Incr YES
Code IRC2003ITP12002
CSI
TC 0.90
BC 0.86
WB 0.34
(Matrix)
I DEFL in (loc) Vdefl Ud
Vert(LL) -0.20 11-12 >999 240
Vert(TL) -0.34 11-12 >999 180
Horz(TL) 0.17 7 nla n/a
PLATES GRIP
MT20 169/123
MT18H 197/144
Weight: 203 lb
LUMBER
BRACING
TOP CHORD 2 X 4 SPF 2100E 1.8E 'Except*
TOP CHORD Structural wood sheathing directly applied or 2-2-0 oc purlins.
T2 2 X 4 SPF 1650F 1.5E, T3 2 X 4 SPF 165OF 1.5E
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
BOT CHORD 2 X 4 SPF 165OF 1.5E
WEBS 1 Row at midpt 2-12, 4-11, 6-10
WEBS 2 X 4 SPF 165OF 1.5E -Except-
W 12 X 4 SPF-S Stud/Std, W 12 X 4 SPF-S Stud/Std
WEDGE
Left: 2 X 10 DF 1950E 1.7E, Right: 2 X 8 DF 195OF 1.7E
REACTIONS (lb/size) 7=2290/0-5-8, 1=2080/Mechanical
Max Horz 1=-289(LC 5)
Max Uplift7=-177(LC 8). 1=-88(LC 7)
Max Grav7=3090(LC 3). 1=2768(LC 2)
FORCES (lb) - Maximum Compression/Maximum Tension
TOP CHORD 1-2=-4032/136, 2-3=-3186/175, 3-4=-2509/159, 4-5=-2509/158, 5-6=-3177/175, 6-7=-4006/125, 7-8=0/197
BOT CHORD 1-13=-258/2953, 12-13=-258/2953, 11-12=-168/2327, 10-11=-43/2325, 9-10=0/2935, 7-9=0/2936
WEBS 2-13=0/262, 2-12=-797/175, 3-12=-43/600, 3-11=-181/988, 4-11=-992/183, 5-11=-184/985, 5-10=-32/605, 6-10=-781/150,
6-9=0/261
NOTES
1) Wind: ASCE 7-98; 90mph; h=25ft; TCDL=4.8psf; BCDL=4.8psf; Category II; Exp C; enclosed; MW FRS interior zone; Lumber DOL=1.33
plate grip DOL=1.33.
2) TCLL: ASCE 7-98; Pf=35.0 psf (flat roof snow); Exp C; Fully Exp.
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 35.0 psf on overhangs non -concurrent
with other live loads.
5) Provide adequate drainage to prevent water ponding.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) All plates are MT20 plates unless otherwise indicated.
8) This truss requires plate inspection per the Tooth Count Method when this truss is chosen for quality assurance inspection.
9) Refer to girder(s) for truss to truss connections.
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 177 lb uplift at joint 7 and 88 lb uplift at joint 1.
11) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job Truss Truss Type
0811022 1 F5 I ROOF TRUSS
1�
Sep 07 10:47:13 2007 Page 1
5-3-10 10-6-3 15-8-12 20-5-11 25-2-10 30-5-3 , 35-7-12 41-2-10 J3-2-1 p
5-3-10 5-2-9 5-2-9 4-8-15 4-8-15 5-2-9 5-2-9 5-6-14 2-0-0
Scale = 1:71.6
e4 =
3x4 = 6x8 =
i0x10 = 3x4 = 5x8 = US = 30 = 8x8 =
F 7-10-15 15-8-12 _ 25-2-10 _ ,33-0-7 41-2-10
7-10-15 7-9-13 9-5-14 7-9-13 B-2-3
LOADING (psf)
SPACING 2-0-0
CSI
DEFL
in (loc) I/deft Ud
PLATES GRIP
TCLL 35.0
Plates Increase 1.15
TC 0.91
Vert(LL)
-0.21 13-14 >999 240
MT20 169/123
(Roof Snow=35.0)
Lumber Increase 1.15
BC 0.69
Vert(TL)
-0.51 13-14 >957 180
TCDL 8.0
Rep Stress Incr YES
W B 0.39
Horz(TL)
0.16 10 n/a n/a
BCLL 0.0
Code IRC2003/TP12002
(Matrix)
Weight: 221 lb
BCDL 8.0
LUMBER
BRACING
TOP CHORD 2 X 4 SPF 165OF 1.5E
TOP CHORD Structural wood sheathing directly applied or 2-9-12 oc purlins.
BOT CHORD 2 X 4 SPF 165OF 1.5E
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2 X 4 SPF 165OF 1.5E *Except'
WEBS
1 Row at midpt 3-14, 5-14, 5-13, 7-13
W 12 X 4 SPF-S Stud/Std, W 12 X 4 SPF-S Stud/Std
WEDGE
Left: 1.5 X 11.88 LSL Truss Grade, Right: 2 X 8 DF 1950F 1.7E
REACTIONS (lb/size) 10=229210-5-8, 1=2082/Mechanical
Max Horz 1=-326(LC 5)
Max Uplift10=-186(LC 8). 1=-98(LC 7)
Max Grav 10=3008(LC 3). 1=2687(LC 2)
FORCES (lb) - Maximum Compression/Maximum Tension
TOP CHORD 1-2=-3924/161, 2-3=-3535/205, 3-4=-2730/200, 4-5=-2024/201, 5-6=-2016/195, 6-7=-2723/193, 7-8=-3292t175,
8-9=-3500/147, 9-10=-3895/133, 10-11=0/197
BOT CHORD 1-15=-258/2905, 14-15=-184/2485, 13-14=-87/2013, 12-13=0/2473, 10-12=0/2881
WEBS 2-15=-461/149, 3-15=-62/561, 3-14=-861/190, 4-14=-42/933, 5-14=-763/203, 5-13=460/205, 6-13=-45/939, 7-13=-852/178,
7-12=-321526, 9-12=-459/133
NOTES
1) Wind: ASCE 7-98; 90mph; h=25ft; TCDL=4.8psf; BCDL=4.8psf; Category II; Exp C; enclosed; MWFRS interior zone; Lumber DOL=1.33
plate grip DOL=1.33.
2) TCLL: ASCE 7-98; Pf=35.0 psf (flat roof snow); Exp C; Fully Exp.
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 35.0 psf on overhangs non -concurrent
with other live loads.
5) Provide adequate drainage to prevent water ponding.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) This truss requires plate inspection per the Tooth Count Method when this truss is chosen for quality assurance inspection.
8) Refer to girder(s) for truss to truss connections.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 186 lb uplift at joint 10 and 98 lb uplift at joint 1.
10) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
0811022 1 F6 I ROOF TRUSS
, Idaho Falls, ID 83403.
7.000 s May 29 2007
5-3-10 10-6-3 , 15-8-12 20-5-11 1 25-2-10 30-5-3 35-7-12 41-2-10 f3-2-10
5-3-10 5-2-9 5-2-9 4-8-15 4-8-15 5-2-9 5-2-9 5-6-14 2-0-0
Scale = 1:70.6
5x8 i
30 = 5x8 -"'
10XIO = 30 = 5x12 = 5x12 = 3x4 = M =
7-10-15 15-8-12 , 25-2-10 , _33-0-7 41-2-10
7-10-15 7-9-13 9-5-14 7-9-13 8-2-3
LOADING (psf)
SPACING
2-0-0
TCLL 35.0
Plates Increase
1.15
(Roof Snow=35.0)
Lumber Increase
1.15
TCDL 8.0
Rep Stress Incr
YES
BCLL 0.0
Code IRC2003/TP12002
LUMBER
TOP CHORD 2 X 4 SPF 165OF 1.5E
BOT CHORD 2 X 4 SPF 165OF 1.5E
WEBS 2 X 4 SPF 165OF 1.5E 'Except'
W 12 X 4 SPF-S Stud/Std, W 12 X 4 SPF-S Stud/Std
WEDGE
Left: 1.5 X 11.88 LSL Truss Grade, Right: 2 X 8 DF 1950E 1.7E
REACTIONS (lb/size) 10=229210-5-8, 1=2082/Mechanical
Max Horz 1=-328(LC 5)
Max Upliftl0=-186(LC 8), 1=-98(LC 7)
Max Grav 1 0=3008(LC 3). 1=2687(LC 2)
CSI
DEFL
in (loc) I/defl Ud
PLATES GRIP
TC 0.91
Vert(LL)
-0.2012-13 >999 240
MT20 169/123
BC 0.69
Vert(TL)
-0.4313-14 >999 180
WB 0.38
Horz(TL)
0.16 10 n/a n/a
(Matrix)
Weight: 221 lb
BRACING
TOP CHORD Structural wood sheathing directly applied or 2-9-14 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS
1 Row at midpt 3-14, 5-14, 5-13, 7-13
FORCES (Ib) - Maximum Compression/Maximum Tension
TOP CHORD 1-2=-3925/159, 2-3=-3536/203, 3-4=-2709/198, 4-5=-2008/201, 5-6=-2001/195, 6-7=-2701/191, 7-8=-3293/174,
8-9=-3502/146, 9-10=-3897/132, 10-11=0/197
BOT CHORD 1-15=-258/2906, 14-15=-186/2484, 13-14=-86/1988, 12-13=0/2472, 10-12=0/2882
WEBS 2-15=-460/149, 3-15=-58/566, 3-14=-887/190, 4-14=-41/919, 5-14=-726/201, 5-13=-723/203, 6-13=-44/926, 7-13=-878/178,
7-12=-29/532, 9-12=-458/133
NOTES
1) Wind: ASCE 7-98; 90mph; h=25ft; TCDL=4.8psf; BCDL=4.8psf, Category II; Exp C; enclosed; MW FRS interior zone; Lumber DOL=1.33
plate grip DOL=1.33.
2) TCLL: ASCE 7-98; Pf=35.0 psf (flat roof snow); Exp C; Fully Exp.
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 35.0 psf on overhangs non -concurrent
with other live loads.
5) Provide adequate drainage to prevent water ponding.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) This truss requires plate inspection per the Tooth Count Method when this truss is chosen for quality assurance inspection.
8) Refer to girder(s) for truss to truss connections.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 186 lb uplift at joint 10 and 98 lb uplift at joint 1.
10) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job Truss Truss Type
G811022 F6-CAP I HIP PI GYBACK I Qty � Ply
1 I FILLMORE/CANYON VIEW J/7
, Idaho Falls, ID 83403, CLAY G. 7.000 s May 29 20D7 MTek Industries, Inc. Fri Sep 07 10:47:16 2007 Page 1
2-0-0 7-5-14 9-5-14 i 11
2-0-0 5-5-14 2-0-0 2-
Scate: 314'=1'
US =
3
04 =
4
30 i 3x4
0-10-15 2-1-12 7-4-2 8-6-15 9-5-14
0-10-15 1-2-13 5-2-6 1-2-13 0-10-15
7)ffsets (X.Yl: 12:0-1-11.0-1-81. 13:0-6-4.0-2-01. 15:0-1-11,0-1-81
LOADING (psf)
SPACING 2-0-0
CSI
DEFL in (loc) Vdefl Ud
PLATES GRIP
TCLL 35.0
Plates Increase 1.15
TC 0.95
Vert(LL) -0.02 7-8 >999 240
MT20 169/123
(Roof Snow=35.0)
Lumber Increase 1.15
BC 0,14
Vert(TL) -0.04 7-8 >999 180
TCDL 8.0
Rep Stress Incr YES
WB 0.12
Horz(TL) 0.01 5 n/a n/a
BCLL 0.0
Code IRC2003/TPI2002
(Matrix)
Weight: 28 lb
RCDL 8.0
LUMBER
TOP CHORD 2 X 4 SPF 165OF 1.5E
BOT CHORD 2 X 4 SPF 165OF 1.5E
WEBS 2 X 4 SPF-S Stud/Std
REACTIONS (lb/size) 2=449/0-5-8, 5=449/0-5-8
Max Horz 2=26(LC 6)
Max Uplift2=-47(LC 6), 5=-47(LC 5)
Max Grav2=653(LC 2), 5=653(LC 3)
FORCES (lb) - Maximum Compression/Maximum Tension
TOP CHORD 1-2=0/39, 2-3=-744/36, 3-4=-491/28, 4-5=-744/35, 5-6=0/39
BOT CHORD 2-8=-31/482, 7-8=-25/491, 5-7=-13/483
WEBS 3-8=0/170, 4-7=0/171, 3-7=-25/25
BRACING
TOP CHORD Structural wood sheathing directly applied or 1-7-8 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES
1) Wind: ASCE 7-98; 90mph; h=25ft; TCDL=4.8psf, BCDL=4.8psf; Category 11; Exp C; enclosed; MWFRS interior zone; Lumber DOL=1.33
plate grip DOL=1.33.
2) TCLL: ASCE 7-98; Pf=35.0 psf (flat roof snow); Exp C; Fully Exp.
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 35.0 psf on overhangs non -concurrent
with other live loads.
5) Provide adequate drainage to prevent water ponding.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 47 lb uplift at joint 2 and 47 lb uplift at joint 5.
8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
9) SEE MiTek STANDARD PIGGYBACK TRUSS CONNECTION DETAIL FOR CONNECTION TO BASE TRUSS
LOAD CASE(S) Standard
0811022 I F7 I ROOF TRUSS I 1 + 1 I Job Reference (optional)
STOCK COMPONENTS -IF, Idaho Falls, ID 83403, CLAY G. 7.000 s May 29 2007 MiTek Industries, Inc. Fri Sep 07 10:47:18
F 5-11-15 11-11-14 1548-12 20-5-11 25-2-10 , 30-5-3 , 35-7-12 41-2-10 13-2-10
5-11-15 5-11-15 3-8-14 4-8-15 4-8-15 5-2-9 5-2-9 5-&14 2-0-0
scare
5x6 �.
30 = 5x8
soot
3x4 It 6x10 - 1.5x4 II 5x8 - 5x8 - 3x4
5-11-15 11-11-14 15-8-12 25-2-10 33-0-7 41-2-10
5-11-15 5-11-15 3-8-14 9-5-14 7-9-13 8-2-3
LOADING (psf)
SPACING 2-0-0
CSI
DEFL in (loc) Vdefl Ud
PLATES GRIP
TCLL 35•0
Plates Increase 1.15
TC 0.78
Vert(LL) -0.20 12-13 >999 240
MT20 169/123
(Roof Snow=35.0)
Lumber Increase 1.15
BC 0.53
Vert(TL) -0.43 13-14 >999 180
TCDL 8.0
Rep Stress Incr YES
WB 0.59
Horz(TL) 0.14 10 n/a Na
BCLL 0.0
nrni R n
Code IRC2003/TP12002
(Matrix)
Weight: 252lb
LUMBER
BRACING
TOP CHORD 2 X 4 SPF 165OF 1.5E
TOP CHORD
BOT CHORD 2 X 4 SPF 165OF 1.5E
WEBS 2 X 4 SPF 165OF 1.5E *Except*
BOT CHORD
W8 2 X 4 SPF-S Stud/Std
WEBS
WEDGE
Right: 2 X 8 DF 195OF 1.7E
REACTIONS (lb/size) 17=2077/Mechanical, 10=2288/0-5-8
Max Horz 17=-368(LC 8)
Max Uplift17=-228(LC 5). 10=-167(LC 8)
Max Grav, 17=2680(LC 2), 10=3005(LC 3)
Structural wood sheathing directly applied or 3-1-2 oc purlins, except end
verticals.
Rigid ceiling directly applied or 10-0-0 oc bracing.
1 Row at midpt 2-16, 3-16, 3-14, 5-14, 5-13, 7-13
2 Rows at 1/3 pts 1-17
FORCES (lb) - Maximum Compression/Maximum Tension
TOP CHORD 1-17=-2623/249, 1-2=-1468/122, 2-3=-1469/122, 3-4=-2627/211, 4-5=-1988/160, 5-6=-1997/206, 6-7=-2697/215,
7-8=-3288/192, 8-9=-3496/165, 9-10=-3891/152, 10-11=0/197
BOT CHORD 16-17=-54/368, 15-16=-68/2327, 14-15=-68/2326, 13-14=-37/1981, 12-13=0/2468, 10-12=-30/2878
WEBS 1-16=-224/2703, 2-16=-871/168, 3-16=-1582/107, 3-15=0/121, 3-14=-906/102, 4-14=-95/942, 5-14=-727/132, 5-13=-724/174,
6-13=-25/928, 7-13=-877/179, 7-12=-30/531, 9-12=-458/134
NOTES
1) Wind: ASCE 7-98; 90mph; h=25ft; TCDL=4.8psf; BCDL=4.8psf; Category II; Exp C; enclosed; MW FRS interior zone; Lumber DOL=1.33
plate grip DOL=1.33.
2) TCLL: ASCE 7-98; Pf=35.0 psf (flat roof snow); Exp C; Fully Exp.
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 20.0 psf or 2.00 times flat roof load of 35.0 psf on overhangs non -concurrent
with other live loads.
5) Provide adequate drainage to prevent water ponding.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) This truss requires plate inspection per the Tooth Count Method when this truss is chosen for quality assurance inspection.
8) Refer to girder(s) for truss to truss connections.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 228 lb uplift at joint 17 and 167 lb uplift at joint
10.
10) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
0811022 1 F7-CAP I HIP PIGGYBACK
1 I 1
I
, Idaho Falls. ID 83403, CLAY G.
7.000 s May 29 2007 MiTek Industries. Inc. Fri Sep 07 10:47:18 2007 Page 1
4-0-0 5-5-14 9-5-14 1 11
4-0-0 1-5-14 4-0-0 2•
Scab: 3!4'=1'
4x4 -
4x8 = 4
3
30 = 3x4 =
0-10-15 4-1-12 5-4-2 8-6-15 9-5-14
0-10-15 3-2-13 1-2-6 3-2-13 0-10-15
LOADING (psf)
SPACING
2-0-0
CSI
DEFL
in (loc)
Vdefl
Ud
PLATES GRIP
TCLL 35.0
Plates Increase
1.15
TC 0.26
Vert(LL)
-0.00 8
>999
240
MT20 169/123
(Roof Snow=35.0)
Lumber Increase
1.15
BC 0.08
Vert(TL)
-0.01 2-8
>999
180
TCDL 8.0
Rep Stress Incr
YES
WB 0.08
Horz(TL)
0.00 5
n/a
n/a
BCLL 0.0
Rrnl an
Code IRC2003/TP12002
(Matrix)
Weight: 29lb
LUMBER
TOP CHORD 2 X 4 SPF 1650F 1.5E
BOT CHORD 2 X 4 SPF 165OF 1.5E
WEBS 2 X 4 SPF-S Stud/Std
REACTIONS (lb/size) 2=44910-5-8, 5=449/0-5-8
Max Horz2=-64(LC 5)
Max Uplift2=-44(LC 7), 5=-44(LC 8)
Max Grav2=589(LC 2), 5=589(LC 3)
FORCES (lb) - Maximum Compression/Maximum Tension
TOP CHORD 1-2=0/39, 2-3=-521/17.3-4=-315/34, 4-5=-522117, 5-6=0/39
BOT CHORD 2-8=-16/316, 7-8=-14/318, 5-7=-1/317
WEBS 3-8=0/86, 4-7=-32/108, 3-7=-73/76
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES
1) Wind: ASCE 7-98; 90mph; h=25ft; TCDL=4.8psf; BCDL=4.8psf; Category II; Exp C; enclosed; MW FRS interior zone; Lumber DOL=1.33
plate grip DOL=1.33.
2) TCLL: ASCE 7-98; Pf=35.0 psf (flat roof snow); Exp C; Fully Exp.
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 35.0 psf on overhangs non -concurrent
with other live loads.
5) Provide adequate drainage to prevent water ponding.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 44 lb uplift at joint 2 and 44 lb uplift at joint 5.
8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSVTPI 1.
9) SEE MiTek STANDARD PIGGYBACK TRUSS CONNECTION DETAIL FOR CONNECTION TO BASE TRUSS
LOAD CASE(S) Standard
an
0811022 I F8 I ROOF TRUSS 12 I 1
Job Reference (optional)
STOCK COMPONENTS -IF, Idaho Falls, ID 83403, CLAY G. 7.000 s May 29 2007 MiTek Industries, Inc. Fri Sep 07 10:47:21 2007 Page 1
5-3-10 10-6-3 15-8-12 20-5-11 25-2-10 30-5-3 35-7-12 41-2-10 443-2-1Q
5-3-10 5-2-9 5-2-9 4-8-15 4-8-15 5-2-9 5-2-9 5-6-14 2-0-0
scale
5x8 G
3x4 = 5x8 O
10x10 = 3x4 = 5x8 = 5x8 = 3x4 = Bx8 =
7-10-15 1 _ 15-8-12
,
25-2-10
33-0-7
41-2-10
7-10-15 7-9-13
9-5-14
7-9-13
8-2-3
Plate Offsets MY): 11:0-5-0,0-2-81, [1:0-3-8,Edael, (4:0-4-12,0-1-121, [6:0-4-12,0-1-121, [10:0-5-9,0-0-81,
[10:0-0-8,Edgel, [13:0-4-0,0-3-01,
(14:0-4-0,0-3-01
LOADING (psf)
SPACING 2-0-0
CSI
DEFL
in (loc)
I/dell
Ud
PLATES GRIP
TCLL 35.0
Plates Increase 1.15
TC 0.91
Vert(LL)
-0.20 12-13
>999
240
MT20 1691123
(Roof Snow=35.0)
TCDL 8.0
Lumber Increase 1.15
BC 0.69
Vert(TL)
-0.43 13-14
>999
180
BCLL 0.0
Rep Stress Incr YES
W B 0.38
Horz(TL)
0.16 10
n/a
n/a
BCDL 8.0
Code IRC2003/TP12002
(Matrix)
Weight: 221 lb
LUMBER BRACING
TOP CHORD 2 X 4 SPF 165OF 1.5E TOP CHORD Structural wood sheathing directly applied or 2-9-14 oc purlins.
BOT CHORD 2 X 4 SPF 165OF 1.5E BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2 X 4 SPF 165OF 1.5E *Except- WEBS 1 Row at midpt 3-14, 5-14, 5-13, 7-13
W 12 X 4 SPF-S Stud/Std, W 12 X 4 SPF-S Stud/Std
WEDGE
Left: 1.5 X 11.88 LSL Truss Grade, Right: 2 X 8 DF 1950E 1.7E
REACTIONS (lb/size) 10=229210-5-8, 1=2082/Mechanical
Max Horz 1=-328(LC 5)
Max Upliftl 0=-1 86(LC 8), 1=-98(LC 7)
Max Grav 1 0=3008(LC 3), 1=2687(LC 2)
FORCES (lb) - Maximum Compression/Maximum Tension
TOP CHORD 1-2=-3925/159, 2-3=-3536/203, 3-4=-2709/198, 4-5=-2008/201, 5-6=-2001/195, 6-7=-2702/191, 7-8=-3293/174,
8-9=-3502/146, 9-10=-3897/132, 10-11=0/197
BOT CHORD 1-15=-258/2906, 14-15=-186/2484, 13-14=-86/1988, 12-13=0/2472, 10-12=0/2882
WEBS 2-15=-460/149, 3-15=-58/566, 3-14=-887/190, 4-14=-41/919, 5-14=-726/201, 5-13=-723/203, 6-13=-44/926, 7-13=-878/178,
7-12=-29/532, 9-12=-458/133
NOTES
1) Wind: ASCE 7-98; 90mph; h=25ft; TCDL=4.8psf; BCDL=4.8psf; Category ll; Exp C; enclosed; MWFRS interior zone; Lumber DOL=1.33
plate grip DOL=1.33.
2) TCLL: ASCE 7-98; Pf=35.0 psf (Flat roof snow); Exp C; Fully Exp.
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 35.0 psf on overhangs non -concurrent
with other live loads.
5) Provide adequate drainage to prevent water ponding.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) This truss requires plate inspection per the Tooth Count Method when this truss is chosen for quality assurance inspection.
8) Refer to girder(s) for truss to truss connections.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 186 Ib uplift at joint 10 and 98 lb uplift at joint 1.
10) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSVTPI 1.
LOAD CASE(S) Standard
Job
0811022 IF9
ROOF TRUSS
3
7.000 s May 29 2007 MTek Industries, Inc. Fri Sep 07 10:47:23 2007
'r
5-3-10 10-6-3 15-8-12 20-5-11 25-2-10 30-5-3 35-7-12 41-2-10 43-2-1?
5-3-10 5-2-9 5-2-9 4-8-15 4-8-15 5-2-9 5-2-9 5-6-14 2-0-0
scare=1:70.5
Sx8 G
3x4 = 5x8
O
I$
3x4 II 8x6 = 5x8 = Sx8 = 3x4 =
4-10-12 7-10-15 1548-12 25-2-10 33-0-7 41-2-10
4-10-12 3-0-3 7-9-13 9-5-14 7-9-13 8-2-3
LOADING (psf)
SPACING 2-0-0
CSI
DEFL
in (loc) Vdefl Ud
PLATES GRIP
TCLL 35.0
Plates Increase 1.15
TC 0.78
Vert(LL)
-0.16 12-13 >999 240
MT20 169/123
(Roof Snow=35.0)
Lumber Increase 1.15
BC 0.49
Vert(TL)
-0.32 13-14 >999 180
TCDL 8.0
Rep Stress lncr YES
WB 0.98
Horz(TL)
0.10 10 n/a n/a
BCLL 0.0
Code IRC2003/TP12002
(Matrix)
Weight: 219lb
BCDL 8.0
LUMBER
BRACING
TOP CHORD 2 X 4 SPF 1650F 1.5E
TOP CHORD Structural wood sheathing directly applied or 3-3-10 oc pudins.
BOT CHORD 2 X 4 SPF 165OF 1.5E
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 2 X 4 SPF 1650F 1.5E'Except-
WEBS
1 Row at midpt 3-15, 5-14, 5-13, 7-13. 2-16
W2 2 X 4 SPF-S Stud/Std, W2 2 X 4 SPF-S Stud/Std
W 12 X 4 SPF-S Stud/Std
WEDGE
Left: 2 X 6 DF No.2, Right: 2 X 8 DF 195OF 1.7E
REACTIONS (lb/size) 10=203110-5-8, 1=122/Mechanical, 16=2216/0-5-8
Max Horz 1=-328(LC 5)
Max UpI1ft10=-186(LC 8), 1=-134(LC 3), 16=-149(LC 7)
Max Grav10=2783(LC 3). 1=305(LC 2), 16=2693(LC 2)
FORCES (lb) - Maximum Compression/Maximum Tension
TOP CHORD 1-2=-226/329, 2-3=-14021130, 3-0-1891/167, 4-5=-1348/164, 5-6=-1703/195. 6-7=-2334/192, 7-8=-2932/174, 8-9=-3141/147,
9-10=-3535/133, 10-11=0/197
BOT CHORD 1-16=-231/225, 15-16=-145/237, 14-15=-138/1291, 13-14=-64/1599, 12-13=0/2181, 10-12=0/2599
WEBS 2-15=0/1326. 3-15=-1124/35, 3-14=-56/575, 4-14=-42/573, 5-14=-970/177, 5-13=-391/290, 6-13=-29/619, 7-13=-884/178,
7-12=-29/542, 9-12=-468/133, 2-16=-2548/159
NOTES
1) Wind: ASCE 7-98; 90mph; h=25ft; TCDL=4.8psf; BCDL=4.8psf; Category II; Exp C; enclosed; MWFRS interior zone; Lumber DOL=1.33
plate grip DOL=1.33.
2) TCLL: ASCE 7-98; Pf=35.0 psf (flat roof snow); Exp C; Fully Exp.
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 35.0 psf on overhangs non -concurrent
with other live loads.
5) Provide adequate drainage to prevent water ponding.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) This truss requires plate inspection per the Tooth Count Method when this truss is chosen for quality assurance inspection.
8) Refer to girders) for truss to truss connections.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 186 lb uplift at joint 10, 134 lb uplift at joint 1
and 149 Ib uplift at joint 16.
10) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
Truss
Truss Type
oly
Ply
FILLMORE/CANYONMEW 917
0811022
F-CAPS
PIGGYBACK
9
1
Job Reference (optional)
I.wu s Mdy cy cwr m i M MUSEnes, uic. rn Jep ur zu:4f:[s zuur rage i
-2-0-0 4-8-15 9-5-14 11-5-14
2-0-0 4-8-15 4-8-15 2-0-0
4A = Scale = 1:18.6
30 = 30 =
0-10-15 4-8-15 8-6-15 9-5-14 ,
0-10-15 3-10-0 3-10-0 0-10-15
LOADING (psf)
TCLL 35.0
SPACING 2-0-0
CSI
DEFL in (loc) I/deft Ud
PLATES GRIP
(Roof Snow=35.0)
Plates Increase 1.15
TC 0.42
Vert(LL) -0.01 4-6 >999 240
MT20 1691123
TCDL 8.0
Lumber Increase 1.15
BC 0.13
Vert(TL) -0.01 4-6 >999 180
BCLL 0.0
Rep Stress Incr YES
WB 0.12
Horz(TL) 0.00 4 n/a n/a
BCDL 8.0
Code IRC2003ITP12002
(Matrix)
Weight: 26 lb
LUMBER
TOP CHORD 2 X 4 SPF 165OF 1.5E
BOT CHORD 2 X 4 SPF 1650F 1.5E
WEBS 2 X 4 SPF-S Stud/Std
REACTIONS (lb/size) 2=449/0-5-8, 4=449/0-5-8
Max Horz2=-77(LC 5)
Max Uplift2=-46(LC 7), 4=-46(LC 8)
Max Grav2=550(LC 2), 4=550(LC 3)
FORCES (lb) - Maximum Compression/MaAmum Tension
TOP CHORD 1-2=0/39, 2-3=-411/24, 3-4=-411/24, 4-5=0/39
BOT CHORD 2-6=0/243, 4-6=0/243
WEBS 3-6=0/170
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES
1) Wind: ASCE 7-98; 90mph; h=25ft; TCDL=4.8psf; BCDL=4.8psf; Category 11; Exp C; enclosed; MWFRS interior zone; Lumber DOL=1.33
plate grip DOL=1.33.
2) TCLL: ASCE 7-98; Pf=35.0 psf (flat roof snow); Exp C; Fully Exp.
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 35.0 psf on overhangs non -concurrent
with other live loads.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 46 lb uplift at joint 2 and 46 lb uplift at joint 4.
7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
8) SEE MiTek STANDARD PIGGYBACK TRUSS CONNECTION DETAIL FOR CONNECTION TO BASE TRUSS
LOAD CASE(S) Standard
10811022
83403, CLAY G. 7.000 s May 29
Ii
11-6-0
11-6-0 7
3A // 13 12 11 10 9 8
11-6-0 ,
11-6-0
Inc. Fri Sep 07 10:47:23 2007
Scale = 1:62.1
LOADING (psf)
SPACING 2-0-0
CSI
DEFL
in (loc) Vdefl Ud
PLATES GRIP
TCLL 35.0
Plates Increase 1.15
TC 0.09
Vert(LL)
n/a - n/a 999
MT20 169/123
(Roof Snow=35.0)
Lumber Increase 1.15
BC 0.02
Vert(TL)
nla - n/a 999
TCDL 8.0
Rep Stress Incr YES
WB 0.30
Horz(TL) 0.00 8 n1a n/a
BCLL 0.0
Code IRC2003ITP12002
(Matrix)
Weight: 83lb
BCDL 8.0
LUMBER
BRACING
TOP CHORD 2 X 4 SPF 1650F 1.5E
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purtins, except end
BOT CHORD 2 X 4 SPF 1650F 1.5E
verticals.
WEBS 2 X 4 SPF 1650F 1.5E
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2 X 4 SPF-S Stud/Std *Except*
WEBS
1 Row at midpt 7-8. 6-9, 5-10
ST5 2 X 4 SPF 1650F 1.5E, ST4 2 X 4 SPF 1650F 1.5E
REACTIONS (lb/size) 1=40/11-6-0, 8=81/11-6-0, 9=208/11-6-0, 10=208/11-6-0, 11=200/11-6-0, 12=210/11-6-0, 13=183/11-6-0
Max Horz 1=401(LC 7)
Max Upliftl=-43(LC 5), 8=-47(LC 7), 9=-108(LC 7), 10=-114(LC 7), l l=-107(LC 7), 12=-113(LC 7), 13=-99(LC 7)
Max Gravl=479(LC 7), 8=119(LC 2), 9=302(LC 2), 10=303(LC 2), 11=291(LC 2), 12=306(LC 2), 13=267(LC 2)
FORCES (lb) - Maximum Compression/Maximum Tension
TOP CHORD 1-2=-614/79, 2-3=-523/107, 3-4=-403/99, 4-5=-289/104, 5-6=-171/100, 6-7=-112/80, 7-8=-104/51
BOT CHORD
WEBS 6-9=-271/131, 5-10=-271f132, 4-11=-259/126, 3-12=-274/135, 2-13=-230/105
NOTES
1) Wind: ASCE 7-98; 90mph; h=25ft; TCDL=4.8psf; BCDL=4.8psf; Category 11; Exp C; enclosed; MWFRS interior zone; Lumber DOL=1.33
plate grip DOL=1.33.
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see MiTek "Standard Gable
End Detail"
3) TCLL: ASCE 7-98; Pf=35.0 psf (flat roof snow); Exp C; Fully Exp.
4) Unbalanced snow loads have been considered for this design.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) All plates are 1.5x4 MT20 unless otherwise indicated.
7) Gable requires continuous bottom chord bearing.
8) Gable studs spaced at 2-0-0 oc.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 43 lb uplift at joint 1, 47 lb uplift at joint 8, 108 lb
uplift at joint 9, 114 lb uplift at joint 10, 107 lb uplift at joint 11, 113 lb uplift at joint 12 and 99 lb uplift at joint 13.
10) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
Truss
Truss Type
Qty
Ply
FILLMORE/CANY ON VIEW W
0811022
HF-131
GABLE
1
1
.lob Reference o tional
STOCK COMPONENTS -IF, Idaho Falls, ID 83403, CLAY G. 7.000 s May 29 2007 MiTek Industries, Inc. Fri Sep 07 10:47:24 2007 Page 1
7-0-12 14-1-8
7-0-12 7-0-12
40 =
3x4
14-1-8
scale = 1:44.7
LOADING (psf)
SPACING 2-0-0
CSI
DEFL in (loc) Vdefl Ud
PLATES GRIP
TCLL 35.0
Plates Increase 1.15
TC 0.07
Vert(LL) n1a - n/a 999
MT20 169/123
(Roof Snow=35.0)
Lumber Increase 1.15
BC 0.02
Vert(TL) n/a - n/a 999
TCOL 8.0
Rep Stress Incr YES
WB 0.26
Horz(TL) 0.00 9 n/a n/a
BCLL 0.0
crni An
Code IRC20017PI2002
(Matrix)
Weight: 69 Ib
LUMBER BRACING
TOP CHORD 2 X 4 SPF 165OF 1.5E TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2 X 4 SPF 165OF 1.5E BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2 X 4 SPF-S Stud/Std 'Except WEBS 1 Row at midpt 5-13
ST4 2 X 4 SPF 165OF 1.5E
REACTIONS (lb/size) 1=47/14-1-8, 9=47/14-1-8, 13=132/14-1-8, 14=196/14-1-8, 15=213/14-1-8, 16=170/14-1-8, 12=196/14-1-8, 11=213/14-1-8, 10=170/14-1-8
Max Harz 1=-226(LC 5)
Max Upliftl=-94(LC 5), 9=-61(LC 6), 14=-101(LC 7), 15=-117(LC 7),16=-91(LC 7), 12=-100(LC 8), 11=-118(LC 8), 10=-91(LC 8)
Max Gravl=218(LC 6). 9=185(LC 5), 13=136(LC 8), 14=301(LC 2), 15=307(LC 2), 16=249(LC 2), 12=301(LC 3), 11=307(LC 3), 10=249(LC 3)
FORCES (lb) - Maximum Compresslon/Maximum Tension
TOP CHORD 1-2=-275/125, 2-3=-208/118, 3-4=-150/107, 4-5=-154/113, 5-6=-154/97, 6-7=-150/65, 7-8=-166/77, 8-9=-235/84
BOT CHORD 1-16=-50/151, 15-16=-50/151, 14-15=-50/151, 13-14=-50/151, 12-13=-50/151, 11-12=-50/151, 10-11=-50/151, 9-10=-50/151
WEBS 5-13=-117/0. 4-14=-269/120, 3-15=-274/138, 2-16=-221/101, 6-12=-269/119, 7-11=-274/138, 8-1 0=-221 /101
NOTES
1) Wind: ASCE 7-98; 90mph; h=25ft; TCDL=4.8psf, BCDL=4.8psf; Category II; Exp C; enclosed; MWFRS interior zone; Lumber DOL=1.33
plate grip DOL=1.33.
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see MiTek "Standard Gable
End Detail"
3) TCLL: ASCE 7-98; Pf=35.0 psf (flat roof snow); Exp C; Fully Exp.
4) Unbalanced snow loads have been considered for this design.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) All plates are 1.5x4 MT20 unless otherwise indicated.
7) Gable requires continuous bottom chord bearing.
8) Gable studs spaced at 2-0-0 oc.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 94 lb uplift at joint 1, 61 lb uplift at joint 9, 101 Ib
uplift at joint 14,117 Ib uplift at joint 15, 91 Ib uplift at joint 16, 100 Ib uplift at joint 12, 118 Ib uplift at joint 11 and 91 lb uplift at joint 10.
10) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
Truss Truss Type
Qty
Ply
FILLMORE/CANYON VIEW 9/7
0811022
HF-F1 GABLE
1
1
Job Reference Donal
STOCK COMPONENTS -IF, Idaho Fails, ID 83403, CLAY G. 7.00u s May z9 zoai MT ek industries, inc. rn Sep ur iu:47:24 2007 rage i
12-8-15 17-3-9 33-1-8
12-8-15 4-6-10 15-9-15
U4 =
30 JO 04 JJ JL a Ju 4V GV a, 4v
5x5 =
33-1-8
33-1-8
Sx5 =
scale = 1:60 0
LOADING (psf)
SPACING 2-0-0
CSI
DEFL
in (loc) l/defl L/d
PLATES GRIP
TCLL 35.0
Plates Increase 1.15
TC 0.12
Vert(LL)
n/a - n/a 999
MT20 169/123
(Roof Snow=35.0)
Lumber Increase 1.15
BC 0.08
Vert(TL)
n/a - n/a 999
TCDL 8.0
Rep Stress Incr YES
WB 0.21
Horz(TL) 0.00 20 n/a n/a
BCLL 0.0
Code IRC2003/TP12002
(Matrix)
Weight: 263lb
BCDL 8.0
LUMBER
BRACING
TOP CHORD 2 X 4 SPF 165OF 1.5E
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins, except end
BOT CHORD 2 X 4 SPF 1650F 1.5E
verticals.
WEBS 2 X 4 SPF 1650F 1.5E
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2 X 4 SPF 165OF 1.5E 'Except'
WEBS
1 Row at midpt 19-20, 8-31, 7-32, 6-33, 9-30. 10-29, 12-28,
ST2 2 X 4 SPF-S Stud/Std, ST1 2 X 4 SPF-S Stud/Std
13-27, 14-26, 15-25. 16-23, 17-22, 18-21
REACTIONS (lb/size) 20=103133-1-8. 1=103/33-1-8, 31=198/33-1-8, 32=205/33-1-8, 33=202/33-1-8, 34=211/33-1-8, 35=183/33-1-8,
36=267133-1-8. 30=205/33-1-8, 29=205/33-1-8, 28=205/33-1-8, 27=204/33-1-8, 26=204/33-1-8, 25=204/33-1-8,
23=205/33-1-8, 22=199/33-1-8, 21=232133-1-8
Max Horz 1=385(LC 6)
Max Uplift20=-20(LC 6), 1=-197(LC 5), 31=-51(LC 6), 32=-95(LC 7), 33=-115(LC 7), 34=-113(LC 7), 35=-98(LC 7), 36=-144(LC
7). 30=-87(LC 8), 29=-95(LC 8), 28=-31(LC 6), 27=-30(LC 6), 26=-30(LC 6), 25=-30(LC 6), 23=-29(LC 6), 22=-31(LC
6). 21=-28(LC 6)
Max Grav 20=1 88(LC 3). 1=438(LC 6), 31=281(LC 8), 32=308(LC 2), 33=294(LC 2), 34=308(LC 2), 35=266(LC 2), 36=390(LC 2)
, 30=332(LC 3), 29=301(LC 3), 28=264(LC 3). 27=278(LC 3), 26=296(LC 3), 25=313(LC 3). 23=331(LC 3). 22=337(LC
3), 21=416(LC 3)
FORCES (lb) - Maximum Compression/Maximum Tension
TOP CHORD 1-2=-565/290, 2-3=455/272, 3-4=-365/262, 4-5=-269/240, 5-6=-261/247, 6-7=-177/242, 7-8=-112/212, 8-9=-125/195,
9-10=-113/109, 10-11=-9/91, 11-12=-3/1, 12-13=-3/1, 13-14=-3/1, 14-15=-3/1, 15-16=-3/1, 16-17=-3/1, 17-18=-311, 18-19=-3/1
,19-20=-169/26
BOT CHORD 1-36=-1/3, 35-36=-1/3, 34-35=-1/3, 33-34=-1/3, 32-33=-1/3, 31-32=-1/3, 30-31=-1/3, 29-30=-1/3, 28-29=-1/3, 27-28=-1/3,
26-27=-1/3, 25-26=-1/3, 24-25=-1/3, 23-24=-1/3, 22-23=-113, 21-22=-1/3, 20-21=-1/3
WEBS 8-31=-262/70, 7-32=-276/114, 6-33=-263/135, 4-34=-272/131, 3-35=-247/122, 2-36=-317/150, 9-30=-299/106,
10-29=-269/114, 12-28=-232/50, 13-27=-246/50, 14-26=-264/49, 15-25=-281/49, 16-23=-299/49, 17-22=-305/48,
18-21=-384/54
NOTES
1) Wind: ASCE 7-98; 90mph; h=25ft; TCDL=4.8psf; BCDL=4.8psf; Category 11; Exp C; enclosed; MW FRS interior zone; Lumber DOL=1.33
plate grip DOL=1.33.
2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see MiTek "Standard Gable
End Detail"
3) TCLL: ASCE 7-98; Pf=35.0 psf (flat roof snow); Exp C; Fully Exp.
4) Unbalanced snow loads have been considered for this design.
5) Provide adequate drainage to prevent water ponding.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) All plates are 1.5x4 MT20 unless otherwise indicated.
8) Gable requires continuous bottom chord bearing.
9) Gable studs spaced at 2-0-0 oc.
Continued on page 2
0811022 I HF-F 1 I GABLE
Sep 07 10:47:24 2007 Page 2
NOTES
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 20 lb uplift at joint 20, 197 lb uplift at joint 1, 51 lb uplift at joint 31, 95 lb uplift at joint 32,
115 lb uplift at joint 33, 113 lb uplift at joint 34, 98 lb uplift at joint 35, 144 lb uplift at joint 36, 87 lb uplift at joint 30, 95 lb uplift at joint 29, 31 lb uplift at joint 28, 30 lb uplift at joint 27,
30 lb uplift at joint 26, 30 lb uplift at joint 25, 29 lb uplift at joint 23, 31 lb uplift at joint 22 and 28 lb uplift at joint 21.
11) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
Truss
Truss Type
oty
Ply
FILLMORE/CANYON VIEW 917
0811022
J1
ROOF TRUSS
8
1
Job Reference(optional)
01 wn IrVIVIrVIVC1V 1 O-W. R/dISU r"tl11.7, Iv 079VJ, {_ILM I V. I v u uVou-, x n,. n . F
-2-0-0 1-11-11
2-0-0 1-11-11 3
Scale = 1:12 7
1-11-11
r — -
LOADING (psf)
SPACING 2-0-0
CSI
DEFL
in
(loc)
I/deft
Ud
PLATES GRIP
TCLL 35.0
Plates Increase 1.15
TC 0.67
Vert(LL)
-0.00
2
>999
240
MT20 197/144
(Roof Snow--35.0)
Lumber Increase 1.15
BC 0.03
Vert(TL)
-0.00
2-4
>999
180
TCDL 8.0
Rep Stress Incr YES
W B 0.00
Horz(TL)
-0.00
3
n/a
n/a
BCLL 0.0
Code IRC2003ITP12002
(Matrix)
Weight: 8lb
BCDL 8.0
LUMBER
TOP CHORD 2 X 4 SPF 165OF 1.5E
BOT CHORD 2 X 4 SPF 165OF 1.5E
REACTIONS (lb/size) 2=384/0-5-8, 4=15/Mechanical, 3=-23/Mechanical
Max Horz2=112(LC 7)
Max Uplift2=-140(LC 7), 3=-174(LC 9)
Max Grav2=584(LC 2), 4=35(LC 4), 3=36(LC 7)
FORCES (lb) - Maximum Compression/Maximum Tension
TOP CHORD 1-2=0/192, 2-3=-178/21
BOT CHORD 2-4=0/0
BRACING
TOP CHORD Structural wood sheathing directly applied or 1-11-11 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES
1) Wind: ASCE 7-98; 90mph; h=25ft; TCDL=4.8psf; BCDL=4.8psf; Category II; Exp C; enclosed; MWFRS interior zone; Lumber DOL=1.33
plate grip DOL=1.33.
2) TCLL: ASCE 7-98; Pf=35.0 psf (flat roof snow); Exp C; Fully Exp.
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 35.0 psf on overhangs non -concurrent
with other live loads.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) Refer to girders) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 140 lb uplift at joint 2 and 174 lb uplift at joint 3.
8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSVTPI 1.
LOAD CASE(S) Standard
Job
Truss
Truss Type
Qty
Ply
FILLMORE/CANYON VIEW 917
0811022
J2
ROOF TRUSS
8
1
Job Reference (optional)
STOCK OCK COmPONENTS-IF,10aho Falls, ID 83403. CLAY G. 7.000 s May 29 2007 MTek Industries, Inc. Fri Sep 07 10:47:25 2007 Page 1
-2-0-0 3-11-11
2-0-0 3-11-11
scale = 1:18 4
3-11-11
LOADING (psf)
TCLL 35.0
SPACING 2-0-0
CSI
DEFL
in
(loc)
I/deft
Ud
PLATES GRIP
(Roof Snow=35.0)
Plates Increase 1.15
TC 0.78
Vert(LL)
-0.01
2-4
>999
240
MT20 197/144
TCDL 8.0
Lumber Increase 1.15
BC 0.10
Vert(TL)
-0.02
2-4
>999
180
BCLL 0.0
Rep Stress Incr YES
WB 0.00
Horz(TL)
-0.00
3
n/a
n/a
BCDL 8.0
Code IRC2003/TP12002
(Matrix)
Weight: 131b
LUMBER
TOP CHORD 2 X 4 SPF 165OF 1.5E
BOT CHORD 2 X 4 SPF 165OF 1.5E
REACTIONS (lb/size) 3=86/Mechanical, 2=444/0-5-8, 4=28/Mechanical
Max Horz 2=152(LC 7)
Max Uplift3=-91(LC 9), 2=-109(LC 7)
Max Grav3=132(LC 2). 2=670(LC 2), 4=63(LC 4)
FORCES (lb) - Maximum Compression/Maximum Tension
TOP CHORD 1-2=0/197, 2-3=-211/54
BOT CHORD 2-4=0/0
BRACING
TOP CHORD Structural wood sheathing directly applied or 3-11-11 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES
1) Wind: ASCE 7-98; 90mph; h=25ft; TCDL=4.8psf; BCDL=4.8psf; Category 11; Exp C; enclosed; MWFRS interior zone; Lumber DOL=1.33
plate grip DOL=1.33.
2) TCLL: ASCE 7-98; Pf=35.0 psf (flat roof snow); Exp C; Fully Exp.
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times fiat roof load of 35.0 psf on overhangs non -concurrent
with other live loads.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 91 lb uplift at joint 3 and 109 lb uplift at Joint 2.
8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
Truss
Truss Type
city
Ply
FILLMORE/CANYON MEW W
Q811022
J3
ROOF TRUSS
7
1
Job Reference tional
STOCK COMPONENTS -IF, Idaho Falls, ID 83403, CLAY G. 7.000 s May 29 20D7 MTek Industries, Inc. Fri Sep 0710:47:25 2007 Page 1
-2-0-0 5-11-11
2-0-0 5-11-11
Scale: 112--1
LOADING (psf)
SPACING 2-0-0
CSI
DEFL in
(loc) Ildefl Ud
PLATES GRIP
TCLL 35.0
Plates Increase 1.15
TC 0.61
Vert(LL) -0.04
2-4 >999 240
MT20 197/144
(Roof Snow--35.0)
Lumber Increase 1.15
BC 0.19
Vert(TL) -0.09
2-4 >697 180
TCDL 8.0
Rep Stress Incr YES
WB 0.00
Horz(TL) -0.00
3 rda n/a
BCLL 0.0
Code IRC2003/TP12002
(Matrix)
Weight: 181b
g
BCDL 8.0
LUMBER
BRACING
TOP CHORD 2 X 4 SPF 210OF 1.8E
TOP CHORD
Structural wood sheathing directly applied or 5-11-11 oc purtins.
BOT CHORD 2 X 4 SPF 210OF 1.8E
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (ib/size) 3=195/Mechanical, 2=522/0-5-8, 4=44/Mechanical
Max Horz 2=195(LC 7)
Max Uplift3=-77(LC 7), 2=-87(LC 7)
Max Grav3=301(LC 2), 2=782(LC 2), 4=99(LC 4)
FORCES (1b) - Maximum Compression/Maximum Tension
TOP CHORD 1-2=0/197, 2-3=-267/142
BOT CHORD 2-4=0/0
NOTES
1) Wind: ASCE 7-98; 90mph; h=25ft; TCDL=4.8psf; BCDL=4.8psf; Category 11; Exp C; enclosed; MWFRS Interior zone; Lumber DOL=1.33
plate grip DOL=1.33.
2) TCLL: ASCE 7-98; Pf=35.0 psf (flat roof snow); Exp C; Fully Exp.
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 35.0 psf on overhangs non -concurrent
with other live loads.
5) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
6) Refer to girder(s) for truss to truss connections.
7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 77 lb uplift at joint 3 and 87 lb uplift at joint 2.
8) This truss is designed in accordance with the 2003 Intemational Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSVTPI 1.
LOAD CASE(S) Standard
Job
Truss
Truss Type
City
Ply
FILLMORE/CANYON VIEW 911
0811022
J3A
ROOF TRUSS
1
1
Job Reference(optional)
5 i UQK (:UMVLX4tNV i ti-ir, wand raus, lu trsWs, L LAT S.D.
r.uuu s may ea cwr as i eK mausEnes, inc. rn pep ur iu:gr:za ewr rage i
scale = 1:21.5
20 -
5-11-11
5-11-11
LOADING (psf)
SPACING 2-0-0
CSI
DEFL
in (loc)
I/defl
Ud
PLATES GRIP
TCLL 35.0
Plates Increase 1.15
TC 0.71
Vert(LL)
-0.06 1-3
>999
240
MT20 197/144
(Roof Snow=35.0)
Lumber Increase 1.15
BC 0.25
Vert(TL)
-0.13 1-3
>522
180
TCDL 8.0
Rep Stress Incr YES
WB 0.00
Horz(TL)
-0.00 2
n/a
n/a
BCLL 0.0
Code IRC2003ITP12002
(Matrix)
Weight: 16lb
BCDL 8.0
LUMBER
TOP CHORD 2 X 4 SPF 210OF 1.8E
BOT CHORD 2 X 4 SPF 165OF 1.5E
REACTIONS (lb/size) 1=283/0-5-8, 2=237/Mechanical, 3=46/Mechanical
Max Horz 1=127(LC 7)
Max Uplift2=-104(LC 7)
Max Gravl=412(LC 2), 2=366(LC 2), 3=103(LC 4)
FORCES (lb) - Maximum Compression/Maximum Tension
TOP CHORD 1-2=-1821182
BOT CHORD 1-3=0/0
BRACING
TOP CHORD Structural wood sheathing directly applied or 5-11-11 oc purtins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES
1) Wind: ASCE 7-98; 90mph; h=25ft; TCDL=4.8psf; BCDL=4.8psf; Category 11; Exp C; enclosed; MWFRS interior zone; Lumber DOL=1.33
plate grip DOL=1.33.
2) TCLL: ASCE 7-98; Pf=35.0 psf (flat roof snow); Exp C; Fully Exp.
3) Unbalanced snow loads have been considered for this design.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 104 lb uplift at joint 2.
7) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
SR
0811022 I M1 I MONO TRUSS 126 I 1 I Jab Reference
STOCK COMPONENTS4F, Idaho Falls, ID 83403, CLAY G. 7.000 s May 29 2W7
-2-0-0 4-0-7 8-0-0
2-0-0 4-0-7 3-11-9
8-0-0
8-0-0
Inc. Fri Sep 0710:47:25 2007 Page 1
Scale = 1:33.3
LOADING (ps35.0
SPACING 2-0-0
CSI
DEFL in (!oc) Udefl Ud
PLATES GRIP
(Roof Snow=35.0)
Plates Increase 1.15
TC 0.46
Vert(LL) -0.19 2-5 >484 240
MT20 169/123
TCDL 8.0
Lumber Increase
BC 0.
Vert(TL) -0.42 2-5 >220 180
BCLL 0.0
Rep Stress Incr YES
WB 0.27
Horz(TL) 0.00 5 Na Na
BCDL 8.0
Code IRC2003/TPI2002
(Matrix)
Weight: 34lb
LUMBER BRACING
TOP CHORD 2 X 4 SPF 1650F 1.5E TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc pudins, except end
BOT CHORD 2 X 4 SPF 1650F 1.5E verticals.
WEBS 2 X 4 SPF-S Stud/Std BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
REACTIONS (lb/size) 2=618/0-5-8, 5=359/0-5-8
Max Horz2=241(LC 7)
Max Uplift2=-73(LC 7), 5=-85(LC 7)
Max Grav2=921(LC 2), 5=520(LC 2)
FORCES (lb) - Maximum Compression/Maximum Tension
rOP CHORD 1-2=0/197, 2-3=-589/9, 3-4=-180/103, 4-5=-223/63
30T CHORD 2-5=-78/310
NEBS 3-5=-390/98
VOTES
1) Wind: ASCE 7-98. 90mph. h=25ft; TCDL=4.8psf; BCDL=4.8psf; Category II; Exp C; enclosed; MWFRS interior zone; Lumber DOL=1.33
plate grip DOL=1.33.
>) TCLL: ASCE 7-98; Pf=35.0 psf (flat roof snow); Exp C; Fully Exp.
3) Unbalanced snow loads have been considered for this design.
1) This truss has been designed for greater of min roof live load of 16.0 psf or 2.00 times flat roof load of 35.0 psf on overhangs non -concurrent
with other live loads.
i) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
i) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 73 lb uplift at joint 2 and 85 lb uplift at joint 5.
) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSUTPI 1.
.OAD CASE(S) Standard
EW
ss Truss Type Qty Ply FILLMOREICANYON MEW W
11022 MONO TRUSS 7 1
Job Reference o Gonal
rOCK COMPONENTS -IF, Idaho Falls, ID 83403, CLAY G. 7.000 s May 29 2007 MiTek Industries, Inc. Fri Sep 07 10.47.25 2007 Page 1
4-0-7 8-0-0
4-0-7 3-11-9
1.5A 11 Scale = 1:30 6
i 3
--� 30 -
8-0-0
(psf)
_ 35.0
-L
SPACING 2-0-0
off Snow=35.0)
Plates Increase 1.15
L
Lumber Increase 1.15
0.0
Rep Stress Incr YES
i.
1 R'A
Code IRC2003/TP12002
ABER
'CHORD 2 X 4 SPF 1650E 1.5E
r CHORD 2 X 4 SPF 1650F 1.5E
BS 2 X 4 SPF-S Stud/Std
1CTIONS (lb/size) 1=389/0-5-8, 4=389/0-5-8
Max Horz 1=172(LC 7)
Max Uplift4=-105(LC 7)
Max Grav1=567(LC 2). 4=567(LC 2)
;CES (lb) - Maximum Compression/Maximum Tension
'CHORD 1-2=-599/0, 2-3=-193/90, 3-4=-202/54
CHORD 1-4=-115/401
3S 2-4=-503/145
CSI DEFL in (loc) I/defl Ud PLATES GRIP
TC 0.42 Vert(LL) -0.19 1-4 >484 240 MT20 169/123
BC 0.46 Vert(TL) -0.42 1-4 >220 180
WB 0.34 Horz(TL) 0.00 4 n/a n/a
(Matrix) Weight: 31 lb
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end
verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
'ES
'ind: ASCE 7-98; 90mph. h=25ft; TCDL=4.8psf; BCDL=4.8psf, Category 11; Exp C; enclosed; MWFRS interior zone; Lumber DOL=1.33
ate grip DOL=1.33.
ALL: ASCE 7-98; Pf=35.0 psf (flat roof snow); Exp C; Fully Exp.
zbalanced snow loads have been considered for this design.
1is truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
ovide mechanical connection (by others) of truss to bearing plate capable of withstanding 105 lb uplift at joint 4.
its truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced
3ndard ANSI/TPI 1.
D CASE(S) Standard