HomeMy WebLinkAboutSHORT FORM - 07-00557 - 593 E 5th S - New SFRLoad Snort Form Job: Canyon —Vim Date: Oct 29, 2007 __ Entire House By: Palmer Heating & Cooli... B & S Boiler, Inc. Project Informat' For: Canyon View, Fillmore Construction Rexburg, ID 0700557 593 E. 5th S. Design Informati Htg Clg Infiltration Outside db ("F) -6 89 Method Simplified Inside db (`F) 70 75 Construction quality Average Design TD (°F) 76 14 Fireplaces 0 Daily range - H Inside humidity (%) 50 50 Moisture difference (gr/Ib) 62 -31 HEATING EQUIPMENT Make Lennox Trade Elite 90 Model G51MP-36C-09V* Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 92.1 AFUE 88000 Btuh 738GO Btuh 70 °F 1140 cfm 0.024 cfm/Btuh 0.80 in H2O COOLING EQUIPMENT Make Lennox Trade 13 ACD Series - RFC Cord 13ACD-024-230' Coil C33-30' Efficiency 13 SEER Sensible cooling 23800 Btuh Latent cooling 0 Btuh Total cooling 23800 Btuh Actual air flow 850 cfm Air flow factor 0.055 cfm/Btu h Static pressure 0.80 in H2O Load sensible heat ratio 1.00 ROOM NAME Area (ft') Htg load (Btuh) Clg load (Btuh) Htg AVF (cfm) Clg AVF (cfm) Bedroom 2 359 3474 598 85 33 B Bath 58 421 11 10 1 Bedroom 3 349 4227 1520 103 84 Mech/Storage 235 0 0 0 0 B Stairs 104 0 0 0 0 Family/Game 1100 10009 2028 244 112 B Closet 55 0 0 0 0 Master Bath 126 1474 240 36 13 M Toilet 32 1348 600 33 33 M WIC 137 1451 247 35 14 Bedroom 1 182 3354 1120 82 62 Office 186 3772 1277 92 71 Stairs 104 0 0 0 0 Toilet 28 341 62 8 3 Laundry 67 378 97 Closet 18 0 0 (� Master Suite 313 2897 1199 I I l Printout certified by ACCA to meet all requirements of Manual J wnghtsoft wgit-suit-Residenbal6.0.107RSR41038 ACCA C'Documents and Setings`tl djotnWly D=mentsPHC\W6ghtsoftPmject U & 80 & S_RIlnnre_Canyon 2007-Orb301026:17 CITY 0 REX_ oeul oo IZO W 3 4 Kitchen 165 2269 2728 55 151 Dining 79 3390 1272 83 70 Great Room 596 5691 1728 139 96 Entry 182 2120 549 52 30 Entire House d 4536 46741 15340 1140 850 Other equip loads 7032 1295 Equip. @ 0.94 RSM 15638 Latent cooling 0 7n7AIC I AKOC cone 44A �v •��ry �vv� VVII'I �JVJV IIIV VJV Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wnghtsoft Rigtt-SuiteResidentia16.0.107RSR41036 2007-Od-301028:17 , Ca C^Documentsard $edingslchnjotnWy D=me MWHC\WnghlsollWmjectgO&SE&S Flimore_Canyon Paget BuildiWAnalysis Wc Entire House B & S Boiler, Inc. For: Canyon View, Fillmore Construction Rexburg, ID ". Job: Canyon -Vim Date: Oct 29, 2007 By: Palmer Heating & Codi_ Location: Indoor: Idaho Falls, ID US 4N1 Indoor temperature (°F) Elevation: ft Latitude: 44°N Design TD (F) Relative humidity (%) Outdoor: Heating Cooling Moisture difference (gr/lb) Dry bulb (°F) -6 89 Infiltration: Daily range F) - 34 ( H) Method Wet bulb (°F - 60 Construction quality Wind speed (mph) 15.0 7.5 Fireplaces Component Btutl/ff, Btuh %of load Walls 3.7 18143 33.7 Glazing 25.7 11023 20.5 Doors 22.0 540 1.0 Ceilings 1.9 4293 8.0 Floors 1.1 2897 5.4 Infiltration 3.9 9845 18.3 Ducts 0 0.0 Piping 0 0.0 Humidification 0 0.0 Ventilation 7032 13.1 Adjustments 0 Total 53774 100.0 Component Btuh/ft` Btuh %of load Walls 0.3 1633 9.8 Glazing 15.6 6680 40.2 Doors 5.4 131 0.8 Ceilings 1.0 2372 14.3 Floors 0.0 2 0.0 Infiltration 0.4 972 5.8 Ducts 0 0.0 Ventilation 1295 7.8 Internal gains 3550 21.3 Blower 0 0.0 Adjustments 0 Total 166: 130.0 Overall U-value = 0.068 Btuh/ft=--°F Data entries checked. Heating Cooling 70 75 76 14 50 50 61.5 31.5 Simplified Average 0 w"Sj"tsoft RIgt4Sulte ReslderNa16.0.107RSR41038 2007-0GJ01028:17 A --CA C:'Docurnents and Seaings\chnjotnNy DoonnenWPHC\Wn9 tsolOProjects\B& S\B& S_Flimore_Canyon Page Compor,rent Constructions Entire House B & S Boiler, Inc. For: Canyon View, Fillmore Construction Rexburg, ID Job: Canyon -View Date: ot:t 29, 2097 By: Palmer Heating & Cooli... Location: Indoor: Heating Cooling Idaho Falls, ID, US Indoor temperature (T) 70 75 Elevation: 4741 ft Design TD (T) 76 14 Latitude: 44°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 61.5 -31.5 Dry bulb (TF) -6 89 Infiltration: Daily range (T) - 34 (H) Method Simplified Wet bulb ff) - 60 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions Or Area U-value Insul R Htg HTM Loss CIg HTM Gain W SWIM--T 1P-'F, h BWW BWh BMW BWh Walls 12F-Osw: Wood stud frame, siding or stucco, no board insulation, n 443 0.065 21.0 4.94 2188 0.47 210 R-21 cavity insulation ne 48 0.065 21.0 4.94 238 0.47 23 e 181 0.065 21.0 4.94 894 0.47 86 s 355 0.065 21.0 4.04 1434 0.39 138 w 482 0.065 21.0 4.94 2381 0.47 229 nw 48 0.065 21.0 4.94 238 0.47 23 all 1558 0.065 21.0 4.73 7374 0.45 708 15811-0wo-6: Basement- 8" concrete, wood framing, interior n 418 0.056 11.0 4.82 2014 0.06 24 finish, R-11 cavity, no board insulation, 6' ne 23 0.056 11.0 4.26 97 0.00 0 e 437 0.056 11.0 3.91 1708 0.08 36 s 572 0.056 11.0 4.08 2333 0.09 49 w 417 0.056 11.0 5.24 2183 0.10 42 nw 23 0.056 11.0 4.26 97 0.00 0 all 1888 0.056 11.0 4.47 8431 0.08 151 Partitions 12F-Osw: Wood stud frame, siding or stucco, no board insulation, 765 0.065 21.0 2.60 1988 0.32 248 M109W*(G5dWtl0frame, siding or stucco, no board insulation, 729 0.240 0.0 0.48 350 0.72 525 no cavity insulation 610: Vinyl Frame, Double Pane, low-E, .35 U-value, .34 SHGC, n 84 0.350 0.0 26.6 2234 11.4 954 dear low-e; NFRC rated (SHGC=0.34); 1.6 ft overhang (7 ft window ht, 1 ft sep.) 61C: Vinyl Frame, Double Pane, Low-E, .35 U-value, .34 SHGC, n 50 0.350 0.0 26.6 1330 11.4 568 dear low-e; NFRC rated (SHGC=0.34); 1.5 it overhang (5 it n 20 0.350 0.0 26.6 532 11.4 227 window ht, 1 It sep.) ne 15 0.350 0.0 26.6 410 25.5 394 ne 15 0.350 0.0 26.6 410 25.5 394 s 40 0.350 0.0 16.6 665 10.3 413 nw 15 0.350 0.0 2&6 410 25.5 394 nw 15 0.350 0.0 26.6 410 25.5 394 all 172 0.350 0.0 24.3 4167 16.2 2783 wriCjhtsoft Rgn-Sut3Residenbal6.0.107RSR41038 2007-Oct-3010:26:17 A --CA cmocuments and Setingsthrijolnwly DoormentsPHMvvdghisoM1Wrojectsra & SO & S_Fi limm_Canyon Page 1 61C: Vinyl Frame, Double Pane, Low-E, .35 _rue, .34 SHGC, n 16 0.350 0.0 „ 26.6 426 11.4 182 dear low-e; NFRC rated (SHGC=0.34); 1.5 ft overhang (4 It n 80 0.350 0.0 26.6 2128 11.4 908 window ht, 1 It sep.) w 20 0.350 0.0 26.6 532 35.4 709 all 116 0.350 0.0 26.6 3086 15.5 1799 61C: Vinyl Frame, Double Pane, Low-E, .35 U-value, .34 SHGC, s 9 0.350 0.0 26.6 233 12.9 113 dear low-e; NFRC rated (SHGC=0.34); 1.5 ft overhang (2.5 ft window ht, 1 ft sep.) 61C: Vinyl Frame, Double Pane, Low-E, .35 U-value, .34 SHGC, s 40 0.350 0.0 26.6 1064 17.9 716 dear low-e; NFRC rated (SHGC=0.34); 1.5 ft overhang (8 ft window ht, 1 ft sep.) 61C: Vinyl Frame, Double Pane, Low-E, .35 U-value, .34 SHGC, w 9 0.350 0.0 26.6 239 35.0 315 dear low-e; NFRC rated (SHGC-0.34); 1.5 ft overhang (3 ft window ht, 1 it sep.) Doors 11PO: Metal door, polyurethane core, no storm s 25 0.290 0.0 22.0 540 5.36 131 Ceilings 16B-38ad: Ceiling undervented attic, no radiant barrier, dark 2294 0.026 38.0 1.87 4293 1.03 2372 shingles, R-38 insulation Floors 91B: Floor over unconditioned basement rooms 290 0.000 0.0 0.00 0 0.00 0 20P-21c: Carpeted floor over open crawl/garage, R-21 blanket 17 0.047 21.0 3.57 62 0.09 2 insulation 21A-32c Carpeted basement floor, No insulation, 32' wide 2259 0.020 0.0 1.25 2835 0.00 0 wnghtsoft Wgrt-suite Residental9.0.107RSR41036 2007-Oct-301029:17 ACCh C:`Docurnents and Setlings'chn)oMwy Doa wts\PHC\Wnghtsort\Projects's&SO& S_Flllmore_Canyon Paget Pro e&oSumma Job: Canyon View 1 rY Date: OctOct29, 007 Entire House By: Palmer Heating & Codi... B & S Boiler, Inc. Project Information For: Canyon View, Fillmore Construction Rexburg, ID Notes: Front of home faces south Weather: Idaho Falls, ID, US Winter Design Conditions Outside db -0 OF Inside db 70 OF Design TO 76 OF Heating Summary Structure 46741 Btuh 0 Btu Central vent (100 cfm) 7032 Btuh Humidification 0 Btuh Piping 0 Btuh Equipment load 53774 Btuh Infiltration Method Simplified Construction quality Average Fireplaces 0 Heatin N Area (ft� 4020 41 Volume (ft') 30037 30037 Air changes/hour 0.28 0.15 Equiv. AVF (cfm) 140 75 Heating Equipment Summary Make Lennox Trade Elite 90 Model G51 MP36C-090-" Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat Summer Design Conditions Outside db 89 OF Inside db 75 OF Design TD 14 OF Daily range H Relative humidity 50 % Moisture difference -31 gr/lb Sensible Coding Equipment Load Sizing Structure 15340 Btuh Ducts 0 Btuh Central vent (100 clim) 1295 Btuh Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.94 Equipment sensible load 15638 Btuh Latent Cooling Equipment Load Sizing Structure -350 Btuh Ducts 0 Btuh Central vent (100 cfm) -1801 Btuh Equipment latent load 0 Btuh Equipment total load 15638 Btuh Req. total capacity at 1.00 SHR 1.3 ton Cooling Equipment Summary Make Lennox Trade 13 ACD Series - RFC Cond 13ACD-024-230` Coil C33-30' 92.1 AFUE Efficiency 88000 Btuh Sensible cooling 73800 Btuh Latent cooling 70 OF Total cooling 1140 cfm Actual air flow 0.024 cfm/Btuh Air flow factor 0.80 in H2O Static pressure Load sensible heat ratio 13 SEER 23800 Btu h 0 Btuh 23800 Btuh 850 cfm 0.055 c8n/Btuh 0.80 in H2O 1.00 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. Wrr4ght50fY RIg"-Suile Residenbal6.0.107RSR41038 2007-Oct-3010:2B:17 ACCA CMocuments and SettingskhrijornWy Dommenls�D14C\WrightsoOWrojectso & S\B & S_Flllmore_Canyon Page 1 4x10 35 d 35 cfm 10x4 33 dm 35 dm o�m 4x 10 0 36 cfm Master Suite aster Bata Q Q 30x6 10x2 175 dm m 4 dm M WIC 10x4 m - 30x6 m 35 dm : 124 dm 10x4 69 cfm Main floor 10x4 T cfm Dring 6" ® 10x4 ® 151 cfm 69 dm Great Room 6x30 278 dm Stairs 14x6 14x6 82 dm 92 dm 4x 10 Bedroom t r 52 dm Gfta 10x4 82 dm 10x4 92 dm Job #: Canyon _View Performed by Palmer Heating Sr Cooli... Canyon View Rexburg, ID q. LJL Lae"dn T-k,01 2 x 10 8 cfm 10x2 9 cfm Garage B & S Boiler, Inc. 1555 W Sunnyside Idaho Falls, ID 83402 Phone: (208) 524-1737 Fax: (208) 524-0801 bsboiler@srv.net Scale: 1 : 141 Page 1 Right-Suhe Residen0al 6.0.107 RSR41038 2007-Od-30 10:29:42 uments and Settings%& Basement Imo- - 10x4 10x4 61 cfm 85 cfm 7„ 14x6 85 cfm B. 2 6 ^ 14x3.25 7 ^ amnvicam� 8" a ciosai 14x14 6.. 6x8 6x8 6 x 8 6x8 254 cf Up 2-103.25 14x8— Q -14X3.2 20x1 i B x 8 m ✓ 6 ^I.. I 6 ^ 7-14x3.25 14x3.25 16 x 8 6" 8 x 8 143.2 b 14x3.25 14 x 10 22 x 10 10x4 14x3.25 4x6 M.Wsw". ascan: 10 Glint 7" 7 ^ 03 cf ... 6 ^ a ..3 7 ^ 10x4 103 cfm 1Ox4 81 cfm 7^ 7^ 8" 2-14x3.25 8x8 4x10 81 cfm 7^ 6^ 6„ 6x8 6x8 Job #: Canyon View g & S Boiler, Inc.ale: 1 : 141 , . Performed by Palmer Heating & Cooli... Page 2 Canyon View 1555 W Sunnyside Right -Suite Residential Idaho Falls, ID 83402 6.0.107 RSR41038 Rexburg, ID Phone: (208) 524-1737 Fax: (208) 524-0801 2007-Oct-30 10:29:43 bsboiler@srv.net C:\Documents and Settings\chrijoh... Duct System Summary Job: Canyon -View') Date: Oct 29, 2007 Entire House By: Palmer Heating & Cooli... B & S Boiler, Inc. Project Information For: Canyon View, Fillmore Construction Rexburg, ID External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.80 in H2O 0.45 in H2O 0.35 in H2O 0.14/0.21 in H2O 0.061 in/100ft 1140 cfm 576 ft Cooling 0.80 in H2O 0,37 in H2O 0.43 in H2O 0.1810.25 in H2O 0.075 in/100ft 850 cfm Supply Branch Detail Table Name Design (Btu h) Htg (cim) Clg (cfm) Design FR Diam (in) H x W (in) Duct Mall Actual Ln (ft) Ftg.Egv Ln (ft) Trunk Bedroom h 3474 85 33 0.072 7.0 OxO VIFx 46.0 155.0 st2 BBath h 421 10 1 0.067 6.0 Ox0 VIFx 29.5 185.0 st2B Bedroom h 4227 103 84 0.068 7.0 OxO VIFx 46.0 165.0 st2A Famiyname-A h 3336 81 37 0.071 7.0 OxO VIFx 48.0 155.0 st3 Familymiame h 3336 81 37 0.072 7.0 Ox0 VIFx 25.0 175.0 st3 Famiy,Game-B h 3336 81 37 0.066 7.0 Ox0 VIFx 45.0 175.0 st3B Master Barn h 1474 36 13 0.071 6.0 Ox 0 VIFx 39.5 165.0 st2 •Toilet c 1348 33 33 0.061 6.0 OxO VIFx 52.5 185.0 st2C •wlc h 1451 35 14 0.068 6.0 Ox0 VIFx 36.0 175.0 st2B Beaman+ h 3354 82 62 0.065 7.0 Ox0 VIFx 46.0 175.0 st2A Office h 3772 92 71 0.065 7.0 Ox0 VIFx 36.0 185.0 st2 Toilet h 341 8 3 0.065 6.0 OxO VIFx 37.0 185.0 st3C Laundry h 378 9 5 0.071 6.0 OxO VIFx 27.5 175.0 st3A Master suite h 1448 35 33 0.066 6.0 OxO VIFx 44.5 175.0 st2 Master suite -A h 1448 35 33 0.063 6.0 OxO VIFx 30.5 200.0 st2 Bath c 65 3 4 0.086 6.0 OxO VIFx 16.5 190.0 st2 Kitc1ten c 2728 55 151 0.082 8.0 OxO VIFx 50.0 165.0 st3A Dining h 3390 83 70 0.062 7.0 Ox0 VIFx 49.5 185.0 st3A Great Room h 2845 69 48 0.064 6.0 Ox0 VIFx 26.0 200.0 st2 Great -A h 2845 69 48 0.073 6.0 OxO VIFx 32.5 165.0 st3 Entry h 2120 52 30 0.072 6.0 Ox0 VIFx 16.5 185.0 st3 wrightsoft Right-Su'ae Residential60.107 RSR41038 2007-Oct-30102817 nCCK c0ocuments and Seffingsklvijotn\My Dommen5\PHC\Wrightsoft\Projects\B&SS&S Fllmore_canyon Pagel Supply Trunk Detail Table Name Trunk Type Htg (cfm) Clg (cfm) Design FIR Veloc (fpm) Diam (in) H x W (in) Duct Material Trunk st2 Peak AVF 619 429 0.061 637 12.7 10 x 14 ShtMetl st1 st2A Peak AVF 263 194 0.061 593 9.2 8 x 8 ShtMetl st2 st2C Peak AVF 33 33 0.061 100 4.3 8 x 6 ShtMetl st2B st2B Peak AVF 79 48 0.061 236 5.9 8 x 6 ShtMetl st2A st3 Peak AVF 521 421 0.062 586 11.9 8 x 16 ShtMetl SO st3A Peak AVF 237 268 0.076 603 8.9 8 x 8 ShtMetl st3 st3B Peak AVF 90 41 0.065 269 6.1 8 x 6 ShtMetl st3A st3C Peak AVF 8 3 0.065 25 2.5 8 x 6 ShtMetl st3B st1 Peak AVF 1140 850 0.061 746 16.0 10 x 22 ShtMetl Name Grill Size (in) Htg (cfm) Clg (cfm) TEL A Design FIR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Matt Trunk rb8 Ox0 225 278 202.5 0.125 440 8.2 2-14x3.25 2-10x18 SJSp rt2 rb1 Ox0 254 113 197.5 0.104 403 8.2 2-14x3.25 2-10x18 SJSp rt3 rb4 Ox0 175 127 257.0 0.080 277 7.5 2-14x3.25 2-10x18 SJSp rt3A t2 Ox0 85 33 269.0 0.076 268 5.8 14x3.25 10x9 SJSp rt3A rb7 0x0 124 82 223.5 0.092 393 6.4 14x3.25 10x9 SJSp rt3 rb6 Ox0 92 71 216.5 0.0951 291 5.7 14x3.25 10x9 SJSp rt3 rb3 Ox0 103 84 300.5 0.068 326 6.4 14x3.25 10x9 SJSp rt3B rb5 Ox0 82 62 338.5 0.061 259 6.0 140.25 10x9 SJSp rt3C Name Trunk Type Htg (cfm) Clg (cfm) Design FIR Veloc (fpm) Diam (in) H x W (in) Duct Material Trunk rt2 Peak AVF 225 278 0.125 626 8.2 8 x 8 ShtMetl rt1 rt3 Peak AVF 915 572 0.061 659 14.7 10 x 20 ShtMetl rt1 rt3A Peak AVF 444 306 0.061 571 11.2 8 x 14 ShtMetl rt3 rt3B Peak AVF 185 146 0.061 555 8.1 8 x 6 ShtMetl rt3A rt3C Peak AVF 82 62 0.061 245 6.0 8 x 6 ShtMetl rt3B rt1 Peak AVF 1140 850 0.061 515 16.0 7-14x3.25 SdJstSp ,L wnghtsoft Rigtt-Suite Residentia16.0.107RSR41038 2007-Oct-301028.17 XCA CnDocuments and Set ngskhrijotn\My D=menMPHCIWnghtsoft\PmjeMV3 & " & S_Flllmre Canyon Page 2