Loading...
HomeMy WebLinkAboutCOMCHECK - 07-00555 - Eclipse Marketing - Remodel"W COMcheck Software Version 3.5.2 Envelope Com 2nns 11=t^_� Report Date: 01/17/08 Data filename: C:\Program Files\Check\COMcheck\Eclipse Marketing bldg.-mk Section 1: Project Information Project Type: New Construction Project Title : Eclipse Marketing Inc. Construction Site: 305 West Main Rexburg, ID 83440 Owner/Agent: Section 2: General Information Building Location (for weather data): Rexburg, Idaho Climate Zone: 16 Heating Degree Days (base 65 degrees F): 8693 Cooling Degree Days (base 65 degrees F): 143 Building -Type, Office Section 3: Requirements Checklist Climate -Specific Requirements: Component Name/Description Floor Area 3840 0700555 Eclipse Marketing Designer/Contractor: Gross Area Cavity Cont. Proposed Budget or Perimeter R-Value R-Value U-Factor U-Factor (a) Budget U-factors are used for software baseline calculations ONLY, and are not code requirements. Air Leakage, Component Certification, and Vapor Retarder Requirements: Lj 1. All joints and penetrations are caulked, gasketed or covered with a moisture vapor-penneable wrapping material installed in accordance with the manufacturer's installation instructions. 2. Windows, doors, and skylights certified as meeting leakage requirements. O 3. Component R-values & U-factors labeled as certified. 4. Insulation installed according to manufacturer's instructions, in substantial contact with the surface being insulated, and in a manner that achieves the rated R-value without compressing the insulation. O 5. Stair, elevator shaft vents, and other dampers integral to the building envelope are equipped with motorized dampers. 6. Cargo doors and loading dock doors are weather sealed. T Recessed lighting fixtures are: (1) Type IC rated and sealed or gasketed; or (it) installed inside an appropriate air -tight assembly with a 0.5 inch clearance from combustible materials and with 3 inches clearance from insulation material. O 8. Building entrance doors have a vestibule and equipped with closing devices. Exceptions: Building entrances with revolving doors. Doors that open directly from a space less than 3000 sq. ft. in area. O 9. Vapor retarder installed. Project Title: Eclipse Marketing Inc. Data filename: C:\Program Files\Check\COMcheck\Eclipse Marketing bldg..cck p EC EE WE E 17 2008 D CITY OF REX 40f /08 COMcheck Software Version 3.5.2 Interior Lighting Compliance Certificate 2003 IECC Report Date: 01/17/08 Data filename: C:\Program Files\Check\COMcheck\Eclipse Marketing bldg..cek Section 1: Project Information Project Type: New Construction Project Titte : Eclipse Marketing Inc. Construction Site: 305 West Main Rexburg, ID 83440 Owner/Agent: Section 2: General Information Building Use Description by: Building Tvoe Floor Area Office 3840 Section 3: Requirements Checklist Interior Lighting: 1. Total proposed watts must be less than or equal to total allowed watts. Allowed Watts Proposed Watts Complies 3840 3714 YES O 2. Exit signs 5 Watts or less per side. Designer/Contractor: Exterior Lighting: O 3. Efficacy greater than 45 lumens/W. Exceptions: Specialized lighting highlighting features of historic buildings; signage; safety or security lighting; low -voltage landscape lighting. Controls, Switching, and Wiring: 4. Independent controls for each space (switch/occupancy sensor). Exceptions: Areas designated as security or emergency areas that must be continuously illuminated. Lighting in stairways or corridors that are elements of the means of egress. O 5. Master switch at entry to hotel motel guest room. O 6. Individual dwelling units separately metered. O 7. Each space provided with a manual control to provide uniform light reduction by at least 50 % . Exceptions: Only one luminaire in space; An occupant -sensing device controls the area; The area is a corridor, storeroom, restroom, public lobby or guest room; Areas that use less than 0.6 Watts/sq.ft. 8. Automatic lighting shutoff control in buildings larger than 5,000 sq.ft. Exceptions: Areas with only one luminaire, corridors, storerooms, restrooms, or public lobbies. Project Title: Eclipse Marketing Inc. Report date: 01/17/08 Data filename: C:\Program Files\Check\COMcheck\Eclipse Marketing bldg..cck Page 2 of 6 9. PhotocelVastronomical time switc' exterior lights. Exceptions: *Sv� Lighting Intended for 24 hour use. 10.Tandem wired one4emp and three -lamp ballasted luminaires (No single -lamp ballasts). Exceptions. - Electronic high -frequency ballasts; Luminaires on emergency circuits or with no available pair. Section 4: Compliance Statement Compliance Statement: The proposed lighting design represented in this document is consistent with the building plans, specifications and other calculations submitted with this permit application. The proposed Lighting system has been designed to meet the 2003 IECC, Chapter 8, requirements In COMcheck Version 3.5.2 and to comply with the mandatory requirements in the Requirements Checklist. Name - Title Signature Date Project Title: Eclipse Marketing Inc. Report date: 01/17/08 Data filename: C:1Program FileslCheWCOMchedclEc fipse Marketing bldg..cck Page 3 of 6 Imw `. COMcheck Software Version 3.5.2 Interior Lighting Application Worksheet 2003 IECC Report Date: Data filename: C:1Progmm Files\Check\COMcheck\Eclipse Marketing bldg..cck Section 1: Allowed Lighting Power Calculation A B C D Floor Area Allowed Allowed Watts Watts 1 ft2 Office 3840 1 3840 Total Allowed Watts = 3840 Section 2: Proposed Lighting Power Calculation A B C D E Fixture ID : Description / Lamp I Wattage Per Lamp / Ballast Lamps/ # of Fixture (C X D) Fixture Fixtures Watt. Office (3840 sq.ft.) Incandescent 1: recessed cans / Incandescent 65W 1 48 65 3120 Compact Fluorescent 1: surface mount / Twin Tube 40W / Electronic 2 9 40 360 Compact Fluorescent 2: surface mount / Spiral 13W / Electronic 2 18 13 234 Total Proposed Watts = 3714 Section 3: Compliance Calculation If the Total Allowed Watts minus the Total Proposed Watts is greater than or equal to zero, the building complies. Total Allowed Watts = 3840 Total Proposed Watts = 3714 Project Compliance = 126 Project Trtie: Eclipse Marketing Inc. Report date:01/17/08 Data filename: C:\Progmm Files\CheddCOMcheck\Eclipse Marketing bldg..cck Page 4 of 6 COMcheck Software Version 3.5.2 Mechanical Compliance Certificate 2003 IECC Report Date: 01/17/08 Data filename: C:\Program Files\Check\COMcheck\Eclipse Marketing bldg..cck Section 1: Project Information Project Type: New Construction Project Title : Eciipse Marketing Inc. Construction Site: 305 West Main Rexburg, ID 83"0 Owner/Agent: Section 2: General Information Building Location (for weather data): Rexburg, Idaho Climate Zone: 16 Heating Degree Days (base 65 degrees F): 8693 Cooling Degree Days (base 65 degrees F): 143 Section 3: Mechanical Systems List Quantity System Type & Description Section 4: Requirements Checklist Designer/Contractor: Project Title: Eclipse Marketing Inc. Report date: 01/17/08 Data filename: C:\Progmm Files\Check\COMcheck\Eclipse Marketing bldg..cck Page 5 of 6 COMcheck Software Version 3.5.2 Mechanical Requirements Description 2003 IECC Report Date: Data filename: C:\Program Files\Check\COMcheck\Eclipse Marketing bldg..cck Project Tale: Eclipse Marketing Inc. Report date: 01/17/08 Data filename: C:\Program Files\Check1COMcheck\Ecipse Marketing bidg..cck Page 6 of 6