HomeMy WebLinkAboutCHECKLIST - 07-00542 - 313 Jill Dr - New SFR-110"%i
RESIDENTIAL PLAN CHECKLIST
(2003 International Residential Code)
Date:•silk
Project: -I._I ,I) -• r,Y� „�,�;�
Building Permit Numben
Job Address: 4
Zoning: i. Number of Stories: Basement: Yes No /Fin. Uial: sf)
(Note unfinished basements as special condition on permit)
Floor Area (sf):_jail finished, "e,,unfinished,, f
garage
The following canin.enfs based on the 20D3 edition of the International Residential Code should be resolved
before a building Penni t'is issued. TI -tis correction list is not a building pen -nit. The approval of plans and
specifications does no- tpermit the violation of any seetion of die Inte�rr7afionalFNus'idential Code or any federal,
state or local regulations.
PLAN CHECK
A. Plans
T a Scale
Plot Plan
/'Legible
Y N -T
,Flood Plain
�/ Floor I Foundation Plan
Section showing construction details
,,--OO'Al1 Bui-I'ding Elevations
Design Criteria(,shall be ideniifed onplans-
as Wind $5 m.p.h., know - 35 fib. Per sq ft.�
,.� Truss Calculation Sheets & /�F1oor Joist Details
,,/�Mechanical Design & Heat Load calc's
Energy Calculations (R320 & Ch 11.)
B. Zoning (circle one)
LDRI 12.,000.sfmin. (XAqdth 80 ft. min)
'D � � 000 sf min. (width 60 ft. min); Duplex 10.,000 sq. ft. min. with C.U.P.
RR2 21,780 sf min. (width 15 0 ft min)Duplex allowed with C.U.P.
Other. (Verify zoning requirements)
-'K���n`RiS ��!','�`-•c:� ,mss--�_ z..,�y..�.�
C. Use
Single Family Duplex (Check coning requirements for approval)
D. Set Backs (taken from eaves)
�Front set back (32 ft. from curb)
Node: 60% im*n of f-ront yard green
� Rear set back (LDR1 25 ft. & LDR2 20 ft.)
Sides set backs (b" for every ft. of building height with LDS - 7-5'min-, & LDR1 - 6'min-)
/y Building -Height (maximum 34 ft.)
E. Footings
,.� Proper Size has per Table 403.1, use 154n psf unless sail Type is known,, Table 40I.4.1 for sQxl bearm�g)
� Rebax (Z-#4 continuous)
Footing Depth (36" below finished grade and 12"' below undisturbed soil; 18" to top of slab -- interior)
F. Foundation
.�-'" roundation walls wl rebax {city ordinance}
�1/2"' Anchor Bolts With 2"x 2N 311 6" square washers
ft
znterior bearing walls) R403.1.6.1-
' Foundation Drainage (foundations an sift soil. shall be designed per R405)
s'
Damp pro ofing/Waterproofi ng to finish grade. R406.1 (fnd.. extends 6" min above grade R404.1-6)
—, .-Craw -Yspace access of I 8" x 24" rnin.. R4£18.3 (may diffex if mech appliance is in crawl space M 13 0 5.1.4)
.�.�..�.µ..�Cr��l-Sace entilationlInsulation —I�f gent per 150 sf. (with moisture barrier
within 3' of each comer (insulae walls vent to inside of home) R448.2
Grad -Ing . pe, away from house. R401-3
G. Frame
t Seismic Hold Dawns and Braced mall Panels (R602-1 0)
/s Floors i oists sized as pear R5D2.3, Wood I joists sued per inanufr•
Joists Under Load BearingPartitians shall be doubled. R502-4
Beams sized. per R502.5 (refer to tables for engineered products)
Cantilevers (comply with R502.3.3 or manuft instruction)
1 sf. er 1500 sq. ft.) and
�_rFloor Sheathing (3/A" min for joists 24"' oc & 5/8" for joists 16" oc) 8503.2.2
fWall (bearing and nonbearing) stud sizes, height & spacing per Table 602.i(5) 8602.3
Headers in Bearing Wall shall be designed as per Tables X02.5(1&2) 8602.7
Roof'Trusses (designed. according to
R802-10-1) 35 9, Snow and 90 mph winds (Local Conditions)
� Rafter and Truss tie -downs. (R80.2.10.5)
Attic Access 22" x 3D" min. rough opening (R807)
H. xterior Covering
Masonry ar�d stucco shah have weather �resis�ive barrier over exterior sheatllin
I. of Covering and Ventilation
Roof Ventilation as per R806
g 8703.2 & 703.9.1
/Asphalt Shingles (slope>2:12) w/ ice protection. (Other type: to camply w/ R905.�
J. Firewalls
_zL"Garage/House drywall separation (project ext. wads & beams supporting haNtable space) R.309.2
�` i)aor from Garage to House (1. 31S" solid wood or steel door,, or 20 min. fire -rated door) R309.1
�
Lh4)e1ling Separation (1 hr fire separation} Su-P-oortin9 structure also rated. R317.1
& Townhouses (2 hr separation & 4' averburn protection or parapet) R317,2
OR4-hpAvalls parallel to and within 3 ft of property line vvl NO openings allowed. R302
2zaelrations.mprevious 3 items to comply with R317*3
K. neral Requirements
House Numbers R321
E/�Half Openable 3sf urindow or Mec � t
—_� h. Vent�lai�an �n bathrooms, mater closets,, and. similar rooms. 8303.3
//IhntU,21n"or and exterior stair illumination shall comply with R303.6.
� Bathroom Fixture clearances comply with Figure R307.2
-� One rooe-'m at least 120 sf.; �Other habitable rooms 70 s�: min wl a min. dimension of 7 ft. R304
*areas w/sloped ceilings fess than 5 ft in height &Jurred ceilings less than 7 ft DO AVOT comply
*50% or more of the required area must be at leaO 7ft high in room.s w/sloped ceiling
,F
Egress clearance from window wells under cantilevered floors. R310.2
Glazincy at Hazardous Locations R308
Emergency Egress in all sleeping rooms and basements with habitable space R310
/�One required Exi't Door shall comply with R311.4
Land'
�gs at fop and bottom of stairways R311.5.4, and each side of each exterior door. R311.4.3
//'Stair Ri.e /Run (7 314" max. rise & 10" min. tread, nosing req' d xf <11") .,f'J Stair Width. (36" min),
fairway Headroom (6' S" min.) /���ndrails (34"to 3$" above stair �.asing)(R31I.5}
Speci
-al- 'r Rns for circular, spiral and winder stairways and bulkhead enclosures R311-5-8
'Stairway Protection (enclosed accessible space under stairs shah be covered with V2" drywall} R31-1.2..2
Y
/"4 Guardrails' compl { with R3 12
.�' Smoke Alarms (each bedroom,, outside bedrooms, and on each level and per NFPA 72) (R 31.3)
L. Energy
Homes with glazing < 15% of grass area of ext. walls (Towmhouses c 25%) to comply w/ Chapter 11.
*Otherwise shall rneet requirejnents ofIECC far respective building tylae. N1 1.(31.2 (seg REScheck)
�/ Vapor retarder on warm in winter side of unventilated walls, ceding and floors R318
*Water Heater heat craps IE+CC 504.7
r� Duct sealing and insulation N1 I
03.3&4 or IECC 503.3.3.3, 503.3.3.4.3
Puns match quantities & values on a'
passing?' REScheck compliance report
M. Mechanical
'�', Gas appliances not in bedrooms, bathrooms, toilet rooms, or storage closes G2406.2
V Room access 24" min wi.dthlAttic access clear opening 20x3OXn.der floor no. 2230. M1305
w18' transition(-5'per 90 degturns)M15a1.3
I��ye�r went length 25'max
F�ue chase on plans? (B -venin require insulation shield throuah insulated assemblies)
C2426.4
i