HomeMy WebLinkAboutJOIST - 07-00504 - 602 Harvest Dr - New SFRTrus Joist
rim board
8
WARNIt
Joists are unstable until bra(
Bracing Includes:
* Blocking • Sheathir
* Hangers - Rim Baa
DO NOT allow workers * Stmt Lines - Rim Joie
to walk on joists
until braced.
INJURY MAY RESULT.
WARNING NOTES
Lack of concern for proper bracing during constructs
Under normal conditions if the following guidelines are
1. All blocking, hangers, rim beams and rim joists at the end supports of flue TJI u
2. Lateral strength, like a braced end wall or an existing deck, must be established or me anus u, um wy. '... -n — "_
by a temporary or permanent deck (sheathing) fastened W Ne first 4 fast effects at the end of the bay.
3. Safety bracing lines of 1x4 (minimum) must be nailed to a braced and wall or sheathed area as in note 2 and to each joist. Without this
bracing, bucking sideways or rollover is highly probable under light construction loads - like a worker or one layer of annulled sheathing.
4. sheathing must be totally attached to each TJI b joist before additional leads can be placed on the system.
5. Ends of cantilevers require safety bracing on both the top and bottom flanges.
6. The flanges must remain straight within a tolerance of X4 from true alignment.
A complete TJ-Xpert framinq plan requires the Trus Joist Framer's Pocket Guide
See Trus Joist Framer's Pocket Guide for Product Trademark Information
NAILING REQUIREMENTS
TJI® joists at bearings: Two 8d (2Y2") box nails (1 each side), 1Yz"
minimum from end.
8lockina panels, rim joist or rim board to bearing plate:
TJI® blocking panels or rim joist: 10d (3") box nails at 6" o.c.
Trus Joist rim board: Toenail with 10d (3") box nails at 6" o.c. or
16d (3Y2") box nails at 12" o.c.
Shear transfer. Connections equivalent to decking nail schedule
Rim board, rim joist or closure to TJI® ist:
13/4" width or less: Two 10d (3") box nails, one each at top and
bottom flange.
2%6"thru 2%2" widths: Two 16d (3Y2') box nails, one each at top and
bottom flange.
31112" width: Toenail joist to rim joist with one 10d (3") box nail each
side of joist top flange.
2x4 minimum squash blocks: Two 10d (3") box nails, one each
at top and bottom flange.
File Nome: rex 9 kevin jensen temple.JOB
Level Name: main floor
Plotted: 10/8/2007 07:25
Design Status:
main floor ..... 9/10/2007 10:20
roof framing ... 9/10/2007 10:19
NOTE: Level design times indicated above provide
assurance for proper level stacking.
Design Methodology ASD
Floor Area Loading Is.
40psf Live Load and 15 psf Dead Load
Maximum Joist Deflection:
L/480 Live Load
U240 Total Load
TJ -Pro Rating Information:
Weighted Average: 58
Lowest Rating: 52
Highest Rating: 66
Glued & Nailed Decking is Required
Direct Applied Ceiling is Not Required
Poured Flooring Overlay is Required
Floor Decking: 23/32" Panels (24" Span Rating)
Normal O.C. Spacing = 16"*
*Unless noted otherwise
rout Scale: 3/16" = 1'
CREATED BY
Stock Building Supply
671 So. Yellowstone
Rexburg, ID 83440
(208) 356-4626
FAX: (208) 356-4508
Cl uxpelrtm
T�70jii A
SYMBOL LEGEND
Point Load
Line Load
Area Load
Detail Collout Label
(See Framer's Pocket Guide)
1 of 2
FOR THE TJ-XPERT WARRANTY
SEE FRAMER'S POCKET GUIDE
Preliminary Layout
for Review and Approval
TJ-Xpert 6.42 (#693) 06.42 D6.42 56.42 P6.42
JOIST AND BEAM LIST
Plot ID
Length
Product
Plies.
Qty
A38
38'
11 7/8" TJI 110 -joist
1
8
A36
36'
11 7/8" TJI 110 joist
1
8
A34
34'
11 7/8" TJI 110 ,foist
1
1
A32
32'
11 7/8" TJI 110 joist
1
5
A24
24'
11 7/8" TJI 110 ,foist
1
16
A16
16'
11 7/8" TJI 110 joist
1
7
A14
14'
11 7/8" TJI 110 joist
1
9
ACCESSORIES LIST
Rm1
16'
1 1/4" x 11 7/8" 1.3E TimberStrand LSL
1
14
Sh1
4' x 8'
23/32" Panels (24" Span Rating)
1
60
Rm, Rim
Board
Cl uxpelrtm
T�70jii A
SYMBOL LEGEND
Point Load
Line Load
Area Load
Detail Collout Label
(See Framer's Pocket Guide)
1 of 2
FOR THE TJ-XPERT WARRANTY
SEE FRAMER'S POCKET GUIDE
Preliminary Layout
for Review and Approval