Loading...
HomeMy WebLinkAboutMULT DOCS - 07-00458 - Interwest Cabinets - Storage Buildingjri�n) C OrE P _",Y °` City of Rexburg REXIiL'RG Amer..:ai Fanul}[mznudry STATE OF IDAHO October 17, 2007 REQUEST FOR A CONDITIONAL BUILDING PERMIT FOR PARTIAL BUILDING CONSTRUCTION TO -.q Building Oficial for the City of Rexburg P.0 Box 280 19 E. Main ;tet. Rexburg, Idaho $3440 Phone (2p8) 359-3020 fax (20$) 359-3022 Pursuant to the provisions of the International Building Code 2000, the undersigned requests that a building permit be issued for-, Footings and Foundations only at: 330 W 1st S Madison, Acknowledgment is made that the plans for the complex are not complete and that final approval of the building will not be given until the final plans have been approved. We recognize that proceeding with portio! construction at this lime is entirely at the risk of the Arch itect/Own e r with there being no assurance that the final Certificate of Occupancy for the entire building or structure will be granted. We further absolve the City of Rexburg and officers and employees thereof, of all resposibility for the issuance of a partial permit and further agree that any work performed under phis permit wiii ue rernvUea or Qrnerwise corrected to be in accord with the requirements of the finql approved plans when a permit for the entire building of stru Dated: Wednesday October 17 2007 Approved: Wednesday October 17 2007 CITY OF REXBURG ermit CooMinator !Tech a finally granted. ti i* Y� 1 R e-1 ail October 12, 2007 Permit Numbers. 07 00458 Project Name: Project Type: Review Item Im Review Action Interwest Cabinets Storage Building Commercial New Building Department Review Exiting Review Structural Review Height and Area Review Building Type Compliance Accessibility Review Plumbing Potable Water Review Waste Water Application Electrical Service Review 19 E. Main St. Rexburg, Who 83440 Phone (2p8) 359-3020 Fax (208) 359-3022 . — hc __ A or ►red Meets code requirements. 10112120Q7 Meets code requirements. Special inspections 10/12/2007 are required for concrete foundation and high strength steel bolting. Provide name of firm doing the inspections. Meets code requirements. 10/12/2007 Building is Type VB. 10/12/2007 Provide ADA into for new restroom . No ele. plan was submitted, need to see at least a power riser diagram. Electrical Energy Lighting Compliance Review Na compliance form was done for this project. Electrical Circuits Review Waste Water Grease Trap Form Plumbing Sewer Drain Review Plumbing Storm Drain Review Water and Sewer Service Building Cade Fire Compliance Review Mechanical Review Energy Conservation Compliance Review N 0 elwas submi#ted, need to know the wiring method that is planned to be used. Make. sire that this is wired to the X005 NEC. Provide details for fire seperatian on new office spice and restroom. Provide mechanical sizing. Provide energy info. Building Safety Depart enf 79 E Main Rexburg, I 83440 joneilh@rexburg.org www..rexburg.org City of Rexburg Phone: 208.359.3020 Fox: 208,359.3024 NII I}fFD % Business Application Quesfionaire (fox the purpose of wastewater permitting) c4w .9' Tvpe of business or establishment? &t4�k12"'ZI aiL-d ea,4& �/-- - - awl, WiU this business be doing any ape of fond preparation or cooking? 3. What t��e of food preparation or cooking w.i.]J. be done? 4. WM there be any deep fat frying? Yes No 1< 5. Will the facility have food disposal systems? 56 I TY 0 F RET x .OW...�� fieri s Family Cotnmun'� G. Aye you a business plannmg to occupy an existing building? or, are you designmg a new facility? 7. �1'ill your business have chem.ical storages des No C S. Will this facihtAT operate yeas round? des No 9, Will there be any grease traps or sumps at the facility? Yes _ _ No 10. Will there be any types of chemicals used at this facility, other than household cleaning solufians? Yes 1\10 11. ls there any manufacturing of products at this facility? Yes No Applicant Signature Date C1 Ty 0 F. October 11, 2007 Perm -it Number: 07 00457 Project Name: Project Type: Review Item Interwest Cabinet Site Plan Review Fire apparatus Access Vicinity Map Provirded Fire Lane Signage Existing Hydrants Proposed H drant. Access to Hydrants Hydrant Flows Provided Fire Sprinkler System Required Required Fire Flow Parcel #'s Review Action Storage Building -Site Plan i PROVIDED PROVIDED NOT REQUIRED 19 E Main St. Rexburg, Idaho $34403 Phone (2D8) 359-3020 Fax (20$) 359-302 ta l Apia rowed NOT ENOUGH EXISTING HYDRANTS TO PROVIDE ADEQUATE FIRE FLOW NO PROPOSED HYDRANTS SHOWN ACCESS TO EXISTING HYDRANT WEST OF PROJECT ON FIRST SOUTH GOOD PLEASE PROVIDE HYDRANT FLOWS FIRE SUPPRESSION SYSTEM REQUIRED REQUIRED FIRE FLOW (F-1 OCCUPANCY) WITH FULL FIRE SUPPRESSION SYSTEM IS 2000 GPM/TWO HOURS FROM A MINIMUM OF TWO HYDRANTS WITHIN 450 FEET OF STRUCTURE 09/21/2007 09121/2007 09/2112007 r- C �C� CITY OF REXBURG OA rp V I IrY 0 F BLTRG- Ainerica'5 Family o�n"Jljni October 12, 2007 Permit Number: 07 00458 Project Name: Project Type: Review Item Review Action Interwest Cabinet. Storage Building Commercial New epar e" w.:-" Exiting Review Structural Review Height and Area Review Building Type Compliance Accessibility Review Plumbing Potable Water Review Waste Water Application Electrical Service Review Electrical Energy Lighting Compliance Review Electrical Circuits Review Waste Water Grease trap Form Plumbing Sewer Drain Review Plumbing Storm Dram Review Water and Sewer Service Building Cade Firs Compliance Review Mechanical Review Energy Conservation Compliance Review 19 E Main St. Rexburg.. Idaho 83440 Phone (208) 359-3020 Fax (208) 359-3022 ions Re aired f Ar) Droved Meets code requirements. Meets code requirements. Special inspections are required for concrete foundation and high strength steel bolting. Provide name of firm doing the inspections. Meets cede requirements. Building is Type VB. Provide ADA info for new restrao No ele. pian was submitted, need to see at least a paver riser diagram., o campliartce formwas done for this projec 10/12/2007 10/12/2007 10/12/2007 10/12/2007 No ele. plan was submitted, need to know the wiring method thatis planned to be used. Mai sure that this is wired to the- 2005 NEC. Provide details for fire seperafion an neer office space and restroom. _ Pro' Pro) I Jkb e400" own S—Pf // �go�/ K�'�i�J�/ �5 a lit i cv-I,A baa ��� s� �� �� Z� — d7z:!!> , zoo� FM2� 2 tole Fo* CL C Z5 � t I C 0 "w1 a 0 L C1) L dpb W -t lb. e 10. 650 cm W aC m 0 CQ OD r 98 z4a 0 4" co 4bOF V) 0 0 t W] TI 0 LL 10/18/2007 08;33 FAX Short Form rEntire House interw t Cabinet Rexburg, ID 83440 Job: Date Bl Interwe�t 4ct I8, 2D07 F rO r 1111%ji ';1& Outside db (°F) Inside db ("F) Design TD (*F:7) Dailyrange Inside humidity Moisture difference (grllb) • �a -6 gg 70 75 76 14 - H 50 -31 Method Construion quality Fireplaces Inflitration SjM-pufied Average v HEATING EQUIPMENT Maki Trade Model Efficiency Heating input Fleeting output Temperature ripe Actual air flow Air flowfaclor stafiC pressure Spee thermostat ROOM NAME Rooml Entire House Other equip wads Equip.a� o.g4 Lqtent ccKajirtg TOTAL$ 80 AFUJE 0 Stub 0 Btuh 0 OF 1787 cfm 0.011 cfm/Btuh 0.00 in H2O COOLING Q MENT hake Trade Coed Coil Efficiency 4 EER Sensible pooling Q Btuh Latent cooling 0 Btuh Total cooling 4 Btuh Actual air flow 1787 cfm Air fOW fartor 0.047 cfm/Btuh Static pressure 0.00 in H20 Load sensibly heat raffia 7.00 1 14641 .;l 11K� 1(01 Printout certified by SICCA to meet all requirements of Manual J 8th Ed. �- w+'nghtsaft n4hc-su11e Resi'dsrnIai 9.0,22 RsRa0e7' PraJactl,r5p Csfc 1W M.f$ OrtentatF4r1 = N C1g AVF (cfm) 1787 2007--1 06:-ag Page