HomeMy WebLinkAboutJOIST - 07-00452 - 282 Pollard Ave - New SFRA complete TJ-Xpert frominq plan requires the Trus Joist Framer's Pocket Guide See Trus Joist Framer's Pocket Guide for Product Trademark Information JOBCOMMENTS CREATED BY Rockwell Development BMC West H-1300 Bonus Room Plan PO Box 1831 Idaho Falls, ID 83403-8340 208-557-5008 FAX: 208-522-2106 �TJXpert. WW4AW JOIST AND BEAM LIST Plot ID Length Product Plies qty Al 36' 117/8" TJI 110,1oist 1 9 A2 34' 117/8" TJI I10,joist 1 8 A3 29' 117/8" TJI 110.loist 1 6 A4 13' 117/8" TJI 110,joist 1 15 MI 12' 13/4" x 117/8" 1.9E Microllom LVL 2 2 Shl 4' x 8' 23/32" Panels (24" Span Rating) 1 44 Rim, Rim Board: Pc, Parallel Closure Rm1 A4 A2 I I Al A3 L 16" n N Rml Roil M1 2 y I= Rm1 JOBCOMMENTS CREATED BY Rockwell Development BMC West H-1300 Bonus Room Plan PO Box 1831 Idaho Falls, ID 83403-8340 208-557-5008 FAX: 208-522-2106 �TJXpert. WW4AW SYMBOL LEGEND Point Load Line Load Area Load O Detail Callout Label (See Framer's Pocket Guide) LEVEL NOTES File Name: Rockwell Development H-1300 Bonus Room.JOB Level Name: Main Plotted: 9/6/2007 14:41 Design Status: Main ......... 9/6/2007 14:36 NOTE: Level design times indicated above provide assurance for proper level stacking. Design Methodology: A50 Floor Area Loodinq Is: 40psf Live Load and 12 psf Dead Load Maximum Joist Deflection: L/480 Live Load L/240 Total Load TJ -Pro Rating Information: Weighted Average: 49 Lowest Ratinq: 42 Highest Rating: 57 Glued d Nailed Deckinq is Required Direct Applied Ceiling of 1/2" Gypsum is Required Poured Flooring Overlay is Required Floor Decking: 23/32" Panels (24" Span Rating) Normal O.C. Spacing = 16"• -Unless noted otherwise Layout Scale: 3/16" = V JOIST AND BEAM LIST Plot ID Length Product Plies qty Al 36' 117/8" TJI 110,1oist 1 9 A2 34' 117/8" TJI I10,joist 1 8 A3 29' 117/8" TJI 110.loist 1 6 A4 13' 117/8" TJI 110,joist 1 15 MI 12' 13/4" x 117/8" 1.9E Microllom LVL 2 2 SYMBOL LEGEND Point Load Line Load Area Load O Detail Callout Label (See Framer's Pocket Guide) LEVEL NOTES File Name: Rockwell Development H-1300 Bonus Room.JOB Level Name: Main Plotted: 9/6/2007 14:41 Design Status: Main ......... 9/6/2007 14:36 NOTE: Level design times indicated above provide assurance for proper level stacking. Design Methodology: A50 Floor Area Loodinq Is: 40psf Live Load and 12 psf Dead Load Maximum Joist Deflection: L/480 Live Load L/240 Total Load TJ -Pro Rating Information: Weighted Average: 49 Lowest Ratinq: 42 Highest Rating: 57 Glued d Nailed Deckinq is Required Direct Applied Ceiling of 1/2" Gypsum is Required Poured Flooring Overlay is Required Floor Decking: 23/32" Panels (24" Span Rating) Normal O.C. Spacing = 16"• -Unless noted otherwise Layout Scale: 3/16" = V ACCESSORIES LIST Plot ID Length Product Plies Qty Rm1 16' 1 1/4" x 117/8" 1.3E Timber5trand LSL 1 7 Pct 33' 10" 117/8" TSI 110,joisl I 1 Pc2 15' Il" 117/8" TJI 110 ,joist 1 I Pc3 12' 10" 117/8" TJI 110.joist 1 1 Pc4 6' 11" 117/8" TJI 110.loist 1 1 Shl 4' x 8' 23/32" Panels (24" Span Rating) 1 44 Rim, Rim Board: Pc, Parallel Closure SYMBOL LEGEND Point Load Line Load Area Load O Detail Callout Label (See Framer's Pocket Guide) LEVEL NOTES File Name: Rockwell Development H-1300 Bonus Room.JOB Level Name: Main Plotted: 9/6/2007 14:41 Design Status: Main ......... 9/6/2007 14:36 NOTE: Level design times indicated above provide assurance for proper level stacking. Design Methodology: A50 Floor Area Loodinq Is: 40psf Live Load and 12 psf Dead Load Maximum Joist Deflection: L/480 Live Load L/240 Total Load TJ -Pro Rating Information: Weighted Average: 49 Lowest Ratinq: 42 Highest Rating: 57 Glued d Nailed Deckinq is Required Direct Applied Ceiling of 1/2" Gypsum is Required Poured Flooring Overlay is Required Floor Decking: 23/32" Panels (24" Span Rating) Normal O.C. Spacing = 16"• -Unless noted otherwise Layout Scale: 3/16" = V