HomeMy WebLinkAboutCHECKLIST - 07-00410 - 251 Polo Dr - New SFRI
IN
1W
RSDEENTIAL PLAN CHECKLIST
Date: ,3 p
r
Project:
(2003 International Residential Code)
Building Permit Number:
Job Address,
�/ G
Zoning: ��� :� Number of Stories: Basement:(,e " No 1 Mn
. Unfin. (Partial.
(Nate unfinished basements as special condition on permit)
Floor Area (sf),, as,7 finished, � 5 � unfinished, ��. garage
sf)
The following comments based on the 200_'_3 edition of the Intemational Residential Code should be resolved
before a building permit is issued. This correction dist is not a building permit. The approval of plans and
specificaions does not pen -nit the violation of any section o�the Int
stale or loca'l regulations.
PLAN CHECK
A. Plans �
✓ Scale Legible
vPlot Plan Y / N Flood Plain
�ioor I Foundation Plan
L/" Section showing construction details
C/ All Btfflding Elevations
emaiional Residential Code or any federal,
Design Criteria (shall be 'Identified on plans. as Wind - $5 m.p.h., Snow - 35 Ib. Per sq ft. )
Truss Calculation Sheets
Floor foist Details
VMechanical Dts*gn & Feat Load talc's
Energy Calculations (R320 & Ch 11)
Be Zon11
ing (circle one)
LDRI 12,000 sfinin. (width 80 ft. min)
LDR2 8.,000 sf min. (width 60 ft. min); Duplex 10,000 sq. ft. min. with C.U.P.
RR2 21,780 sf min. (width 150 ft min) Duplex allowed with C.U.P.
Other (Verify zoning requirements)
C�Tse
t Singh Family Duplex(Check zoning requirements for approval)
D.$eteBacks(taken from eaves)
�/ Front set back (3Z ft. from curb)
Note: 60% min of front yard green
c -'Pe
Z Rear set back (LDRI 25 ft. & LDR2 20 ft.)
Sides seg hacks (6" for eery ft. of building height with LDR - 7.5' min., & LDRI - 6' aurin.}
t/Buildiong-Height (maximum 30 ft.)
E. otings
�-
Proper 5i�e (as per Table X03.1, use 15Q0 psf unless soil Type is kjiovNm., Table 401.4.1 fox saxX bearing)
Rebar (2-#4 continuous)
✓Footing Depth (36" below finished grade and 12" below undisturbed soil; 18" to top of slab
F. Foundation
V�Foundation walls Irl reba.r (city ordinance)
interior}
tf ].Iz" Anchor Bolts with 2"x 2"x 3/1651 square washers (Inel. interior bearing wads) R403.1.6.1
Foundation Draina e foundations on sift soil shall be designed per R405}
g {
V Damp p to finish grade.1�446.1 (fnd. extends 6"" min above grade R404.1.6)
� Crawl. -space access of 18" x 24" min.
R4083 (may differ if mech appliance is in crawl space M 13 0 5.1-4)
,°rrCrawl St)ace Vent1lat'ion/Insulation =%
sfvent per 15[l sf. (with maistuxe barrier 1 sf. per 1500 sq. ft.) and
within 3' of each comer (insulate wads vent to inside of home) R408-2
A
1 r x house*R401.3 rading Z:,
G. Frame
L_/c Hold Downs and Braced Wail Panels (R602.10)
r
Floors j oists sized as per R502 *3,
Wood 1 -Joists sized per manuft.
foists Under Load BiearncyC? Partitions shall be doubled. R502.4
�o tables for en ieered prod
xa.uc�s�Bears sized per RSQZ.5 (refer �
dolicantilevers (coinply with �.i
�02.3.3 or manu�r instruction)
h
0
-21-Floor Sheathing (3/4"' min forJoists 24" ac & 518" forjojst� �6"oc) X503.2.2
ZVail (bearing and nonbearing) stud sizes, height & spacYng per Table G�2.45) R6023
,i Headers M Bearing Wall shall be designed as per Tables 502.5 (1 &2 R602@7
Roof Trusses (designed nccording to R802.10.1) 35 # Silow mid gD mph winds (Local Conditions)
Rafter and Truss hoe-downs. �602.1 U.5}
ZAAccess 22" x 3011 min. rough opening (R807)
HexteriorFCovering
��Masonry and stucco shall have weather resistive barrier over exterior shea
I. loaf Covering and Ventilation
Roof Ventilation as per R806
Asphalt
h ing 8703.2 & 703.9.1
Shingles (slope,>2,12) w/ ice protection. (Other type: to comply w/ R905._�)
J. rewalls
f�
Garage/House drywall separatian protect ext,
Door from Garnae to House �I
walls & beams supporting habitable space) R309.2
3l8" solid wood or steel door, or 20 min. fire -rated door) R309.1
UZ
-I WO -P. arra � Dwelling Separation (I hr fire separation) Sup -porting structure alio rated. R317.1
T�onac-s'& Townhouses (2 hr separation & 4' overburn protection or parapet) 8317.2
_paralrel to and tiv-ithin 3 ft of properly line wl NO openings allowed, R302
Pg=trali-Qns1i1 previous 3 ItPMS tL0 C4111PIY with R317.3
K. General Requirements
Mouse Numbers X321
Half operable 3sf window or Mech. 'Ventilation in bathroorris, water closets, and similar rooms. R3033
/Trtenor and exterior stairillumination shall e.ompiy with R303.6.
r�Bathroorn Fixture clearances comply with Figure R.307.2
One room at least 120 sf -.��l��t�r bf-rA;tnAr-7n
*meas ivI
• 5 llil `+ X11 WW
a min. dimension of 7 int. R304
4) 1uPLOu ceacIngs cess than .) It in height & furred ceilinor.v le v v th ry 7 7 41 nn Arn-P
50Yo or more of the req icired area must be at least 7ft high in rooms wI sl, nw'd npHill or IV Y
Eess clearance from window wells under cantilevered floors R3102
lazing at Hazardous Locations R308
er enc E cress in all sleeping rooms and basements with habitable space R310
I.." -Vce/ Qne required Exit Door shall comply with 831 1 .4
0
landings at top and bottom of stairways 8311.5.4, and each side of each exterior door. R311e4*3
I
Mair Rise""
1 Run (7 3 14" max. rise & �.a" mid. tread, nosing �req'd if < I 1"�;.St air Width (3611 mini,
:
/Starrway Headroom (68" min.).} Handrails (34"to 38"' above stair nosing)(R311.5)
---� p--eci conditions fog cixcular, spiral azad wider stairways and bulkhead enclosures 8311.5..8
S-iL�a�vv �oectlnon (enclosed accessible space under stairs shall be covered with 1/2" drywall) RML2*2
Guardrails complying 14th 8312
r
Smoke Alarms each bedroom,.,outside bedrooms,and an each bevel and per
_1Z_
NFPA 72) (R 313)
L. Energy
ZpHomes
withglazincy � 15% of grass area of ext. u�a11s (Townhouses < 2S°/a) to comply wl Chapter 11.
*Otherwise shall meet requirements of IEC 'fog respective building type. N1101.2 {see REScheck)
Vapor retarder on warm in Avinter side of unventilated walls!) ceiling and floors 8318
*Water Heater head traps IECC 504-07
L,, -//Duct sealing and insulation N 1103 *3 & 4 or IEC C 5 03.3.3.3, 5U3 .3 .3 . 4 .3
Pans match quantities & values on a "passim" REScheck compliance report
L..Z
M. Mechanical
✓aha�nliances got in bedrooms, bathrooms, toIlet rooms,, or storage closets G2406.2MMMM�
t/ Room access 24" min width/Attic access clear opening 20x3O/Under floor no. 22x30. M1305
�Dryer Vent length 25' max wl S' transition (-5' per 94 dna turns) M1:501.3
Flue chase on plans? (B -vents require insulation shied through insulated asse
mblies) G2426.4
51'
y1
a