Loading...
HomeMy WebLinkAboutCOMPLIANCE CERTIFICATES - 07-00387 - American Self Storage - Addon COMcheck Software VE Envelope Com 0700387 American Self Storage Addition 2003 IECC Report Date: 08/13/07 Data filename: C:\Program Files\Check\COMcheck\American Self Storage Building No. 1.cck Section 1: Project Information Project Title: American Self Storage - Bldg. No. 1 Construction Site: 270 American Street Rexburg, ID 83440 Owner/Agent: Danny Miller American Self Storage 270 American Street Rexburg, ID 83440 208-656-9911 Section 2: General Information Building Location (for weather data). Climate Zone: Heating Degree Days (base 65 degrees F) Cooling Degree Days (base 65 degrees F) Project Type: Vertical Glazing / Wall Area Pct.: Activity Tvoelsj Storage, Industrial and Commercial Convention, Conference or Meeting Center Rexburg, Idaho 16 8693 143 New Construction 2% Section 3: Requirements Checklist Envelope PASSES: Design' 15%Metter than code. Climate-Specific Floor Area 10250 750 Design er/Contractor: Tech -Fast Self Storage Buildings 615 Commerce St. Tacoma, WA 98402 253-572-4440 �� AUG 1 5 2007 'I ��� CITY OF Name/Description Gross Area Cavity or Perimeter R-Value Cont. R-Value Proposed U-Factor Budget U-Factor Roof 1: Metal Roof with Thermal Blocks 11000 0.0 19.0 0.051 0.047 Exterior Wall 1: Metal Frame, 16" o.c. 4386 0.0 11.0 0.075 0.067 Window 1: Metal Frame:Double Pane, Tinted, SHGC 0.06 20 -- -- 0.600 0.520 Window 2: Metal Frame:Double Pane, Tinted, SHGC 0.06 20 --- --- 0.600 0.520 Door 1: Glass, Tinted, SHGC 0.58 42 -- -- 0.700 0.620 Door 2: Solid 30 -- --- 0.060 0.112 Door 3: Solid 30 -- -- 0.060 0.112 Door 4: Solid 30 --- -- 0.060 0.112 Door 5: Solid 30 -- -- 0.060 0.112 Interior Wall 1: Wood Frame, Any Spacing 750 0.0 11.0 0.071 0.112 Interior Wall 2: Metal Frame, 16" o.c. 15000 0.0 11.0 0.074 0.112 Floor 1: Slab-On-Grade:Unheated, Vertical 3 ft. 510 -- 0.0 — -- (a) Budget U-factors are used for software baseline calculations ONLY, and are not code requirements. Air Leakage, Component Certification, and Vapor Retarder Requirements: 1. All joints and penetrations are caulked, gasketed or covered with a moisture vapor -permeable wrapping material installed in accordance with the manufacturer's installation instructions. American Self Storage - Bldg. No. 1 Page 1 of 9 ❑ 2. Windows, doors, and skylights &ftp�ed as meeting leakage requirements. t ❑ 3. Component R-values & U-factors labeled as certified. 4. Insulation installed according to manufacturer's instructions, in substantial contact with the surface being insulated, and in a manner that achieves the rated R-value without compressing the insulation. ❑ 5. Stair, elevator shaft vents, and other dampers integral to the building envelope are equipped with motorized dampers. 6. Cargo doors and loading dock doors are weather sealed. ❑ 7. Recessed lighting fixtures are: (i) Type IC rated and sealed or gasketed; or (ii) installed inside an appropriate air -tight assembly with a 0.5 inch clearance from combustible materials and with 3 inches clearance from insulation material. Lj 8. Building entrance doors have a vestibule and equipped with closing devices. Exceptions: Building entrances with revolving doors. Doors that open directly from a space less than 3000 sq. ft. in area. 9. Vapor retarder installed. Section 4: Compliance Statement Compliance Statement: The proposed envelope design represented in this document is consistent with the building plans, specifications and other calculations submitted with this permit application. The proposed envelope system has been designed to meet the 2003 IECC requirements in COMcheck Version 3.4.2 and to comply with the mandatory requirements in the Requirements Checklist. Name - Title Signature Date Project Notes: Building No. 1 (includes office space) American Self Storage - Bldg. No. 1 Page 2 of 9 r4 COMcheck Software Version 3.4.2 W., Lighting Compliance Certificate 2003 IECC Report Date: 08/13/07 Data filename: C:\Program Files\Check\COMcheck\American Self Storage Building No. 1.cck Section 1: Project Information Project Title: American Self Storage - Bldg. No. 1 Construction Site: 270 American Street Rexburg, ID 83440 Owner/Agent: Danny Miller American Self Storage 270 American Street Rexburg, ID 83"0 208-656-9911 Section 2: General Information Building Use Description by: Activity Type Project Type: New Construction Activity yp3jf5) Floor Area Storage, Industrial and Commercial 10250 Convention, Conference or Meeting Center 750 Section 3: Requirements Checklist Interior Lighting: J 1. Total actual watts must be less than or equal to total allowed walls. Allowed Watts Actual Watts Complies 9175 1496 YES ❑ 2. Exit signs 5 Watts or less per side. Designer/Contractor: Tech -Fast Self Storage Buildings 615 Commerce St. Tacoma, WA 98402 253-572-4440 Exterior Lighting: Lj 3. Efficacy greater than 45 lumens/W. Exceptions: Specialized lighting highlighting features of historic buildings; signage; safety or security lighting; low -voltage landscape lighting. Controls, Switching, and Wiring: 4. Independent controls for each space (switch/occupancy sensor). Exceptions: Areas designated as security or emergency areas that must be continuously illuminated. Lighting in stairways or corridors that are elements of the means of egress. ❑ 5. Master switch at entry to hotel/motel guest room. Fi 6. Individual dwelling units separately metered. Lj 7. Each space provided with a manual control to provide uniform light reduction by at least 50%. Exceptions: Only one luminaire in space; An occupant -sensing device controls the area; The area is a corridor, storeroom, restroom. public lobby or guest room; American Self Storage - Bldg. No. 1 Page 3 of 9 Areas that use less than 0.61rAs/sq.ft. lIwI rl 8. Automatic lighting shutoff control in buildings larger than 5,000 sq.ft. Exceptions: Areas with only one luminaire, corridors, storerooms, restrooms, or public lobbies. ❑ 9. Photocell/astronomical time switch on exterior lights. Exceptions: Lighting intended for 24 hour use. 171 10.Tandem wired one -lamp and three -lamp ballasted luminaires (No single -lamp ballasts). Exceptions: Electronic high -frequency ballasts; Luminaires on emergency circuits or with no available pair. Section 4: Compliance Statement Compliance Statement: The proposed lighting design represented in this document is consistent with the building plans, specifications and other calculations submitted with this permit application. The proposed lighting system has been designed to meet the 2003 IECC, Chapter 8, requirements in COMcheck Version 3.4.2 and to comply with the mandatory requirements in the Requirements Checklist. Name - Title American Self Storage - Bldg. No. 1 Signature Date Page 4 of 9 COMcheck Software Version 3.4.2 Lighting Application Worksheet 2003 IECC Report Date: Data filename: C:\Program Files\Check\COMchec0American Self Storage Building No. 1.cck Section 1: Allowed Lighting Power Calculation A B C D Area Category Floor Area Allowed Allowed Watts (ft2) Watts / ft2 (B x C) Storage, Industrial and Commercial 10250 0.8 8200 Convention, Conference or Meeting Center 750 1.3 975 Total Allowed Watts = 9175 Section 2: Actual Lighting Power Calculation A B C D E Fixture ID : Description / Lamp / Wattage Per Lamp / Ballast Lamps/ # of Fixture (C X D) Fixture Fixtures Watt. Storage, Industrial and Commercial (10250 sq.ft.) Linear Fluorescent 2: 36" T8 25W / Electronic 2 40 23 920 Convention, Conference or Meeting Center (750 sq.ft.) Linear Fluorescent 3. 48" T8 32W (Super T8) / Electronic 1 9 64 576 Total Actual Watts= 1496 Section 3: Compliance Calculation If the Total Allowed Watts minus the Total Actual Watts is greater than or equal to zero, the building complies. Total Allowed Watts = 9175 Total Actual Watts = 1496 Project Compliance = 7679 ■-code; American Self Storage Bldg. No. 1 Page 5 of 9 COMcheck Software Version 3.4.2 JrLPs - Mechanical Compliance Certificate 2003 IECC Report Date: 08/13/07 Data filename: C:\Program Files\Check\COMcheck\Amerlmn Self Storage Building No. 1.cck Section 1: Project Information Project Title: American Self Storage - Bldg. No. 1 Construction Site: Owner/Agent: Designer/Contractor: 270 American Street Danny Miller Tech -Fast Self Storage Buildings Rexburg, ID 83440 American Self Storage 615 Commerce St. 270 American Street Tacoma, WA 98402 Rexburg, ID 83440 253-572-4440 208-656-9911 Section 2: General Information Building Location (for weather data): Rexburg, Idaho Climate Zone: 16 Heating Degree Days (base 65 degrees F): 8693 Cooling Degree Days (base 65 degrees F): 143 Project Type: New Construction Section 3: Mechanical Systems List Quantity System Type 8 Desctlption 1 HVAC System 1: Packaged Terminal Heat Pump, Cooling Capacity 7000 Btu/h, Air -Cooled Condenser / Single Zone 1 Water Heating 1: Service Water Heater w/ Heat Trace Tape Installed Section 4: Requirements Checklist Requirements Specific To: HVAC System 1 : FI 1. Equipment minimum efficiency: Heat Pump: 3.0 COP, 10.8 EER Lj 2. Heat pump thermostat required when supplemental electric resistance heal is installed Requirements Specific To: Water Heating 1 ❑ 1. Heat traps in inletloutlet fittings ri 2. 1/2-in. insulation on 8 it of inletioutlet piping if no integral heal traps i7 3. Automatic on/off control required for systems using heat trace tape 4. Unknown hot water system type. Efficiency requirements can not be determined. Generic Requirements: Must be met by all systems to which the requirement is applicable: 1. Load calculations per 2001 ASHRAE Fundamentals Lj 2. Plant equipment and system capacity no greater than needed to meet loads - Exception: Standby equipment automatically off when primary system is operating - Exception: Multiple units controlled to sequence operation as a function of load 3. Minimum one temperature control device per system 4. Minimum one humidity control device per installed humidification/dehumidification system Li 5. Automatic shut-off dampers on exhaust systems and supply systems with airflow >3,000 cfm LJ 6. Outside -air source for ventilation; system capable of reducing OSA to required minimum American Self Storage - Bldg. No. 1 Page 6 of 9 7. Operation and maintenance ma�( provided to building owner 8. Newly purchased service water heating equipment meets the efficiency requirements Fi 9. Water heater temperature controls: 110 degrees F for dwelling units or 90 degrees F for other occupancies Li 10.Stair and elevator shaft vents are equipped with motorized dampers Section 5: Compliance Statement Compliance Statement: The proposed mechanical design represented in this document is consistent with the building plans, specifications and other calculations submitted with this permit application. The proposed mechanical systems have been designed to meet the 2003 IECC requirements in COMcheck Version 3.4.2 and to comply with the mandatory requirements in the Requirements Checklist. Name - Title Signature Date American Self Storage - Bldg. No. 1 Page 7 of 9 COMcheck Software Version 3.4.2 Mechanical Requirements Description 2003 IECC Report Date: Data filename: C:\Program Files\Check\COMcheck\American Self Storage Building No. t.cck The following list provides more detailed descriptions of the requirements in Section 4 of the Mechanical Compliance Certificate. Requirements Specific To: HVAC System 1 1. The specified heating and/or cooling equipment is covered by the ASHRAE 90.1 Code and must meet the following minimum efficiency: Heat Pump: 3.0 COP, 10.8 EER 2. Heat pumps having supplementary electric resistance heat must have controls that, except during defrost, prevent supplementary heat operation when the heat pump can meet the heating load. Requirements Specific To: Water Heating 1 : 1. Heat traps are required on noncirculating water heating systems on both inlet and outlet connections. Heat traps may be purchased or field -fabricated by creating a loop or inverted U-shaped arrangement on the inlet and outlet pipes. 2. Pipe insulation for the specified noncirculating service hot water system is required for all piping in the following categories:a) the first 8 ft of outlet piping from any constant -temperature, noncirculating storage systemb) the inlet piping between the storage tank and a heat trap in a noncirculating storage systemPipe insulation must be at least 1/2 in. and have a conductivity no >0.28 Btu-in/(h-ft2-degrees F). 3. Systems using heat trace tape must have a time switch control that can automatically turn off the system during unoccupied hours. 4. Service water heating equipment used solely for heating potable water, pool heaters, and hot water storage tanks must meet the following miniumum efficiency: Unknown hot water system type. Efficiency requirements can not be determined. Generic Requirements: Must be met by all systems to which the requirement is applicable: 1. Design heating and cooling loads for the building must be determined using procedures in the ASHRAE Handbook of Fundamentals or an approved equivalent calculation procedure. 2. All equipment and systems must be sized to be no greater than needed to meet calculated loads. A single piece of equipment providing both heating and cooling must safisfy this provision for one function with the capacity for the other function as small as possible, within available equipment options. - Exception: The equipment and/or system capacity may be greater than calculated loads for standby purposes. Standby equipment must be automatically controlled to be off when the primary equipment and/or system is operating. - Exception: Multiple units of the same equipment type whose combined capacities exceed the calculated load are allowed if they are provided with controls to sequence operation of the units as the load increases or decreases. 3. Each heating or cooling system serving a single zone must have its own temperature control device. 4. Each humidification system must have its own humidity control device. 5. Outdoor -air supply systems with design airflow rates >3,000 cfm of outdoor air and all exhaust systems must have dampers that are automatically closed while the equipment is not operating. 6. The system must supply outside ventilation air as required by Chapter 4 of the International Mechanical Code. If the ventilation system is designed to supply outdoor -air quantities exceeding minimum required levels, the system must be capable of reducing outdoor -air flow to the minimum required levels. 7. Operation and maintenance documentation must be provided to the owner that includes at least the following information:a) equipment capacity (input and output) and required maintenance actionsb) equipment operation and maintenance manualsc) HVAC system control maintenance and calibration information, including wiring diagrams, schematics, and control sequence descriptions; desired or field -determined set points must be permanently recorded on control drawings, at control devices, or, for digital control systems, in programming commentsd) complete narrative of how each system is intended to operate. 8. Service water heating equipment must meet minimum Federal efficiency requirements included in the National Appliance Energy Conservation Act and the Energy Policy Act of 1992, which meet or exceed ASHRAE 90.1 Code. New service water heating equipment can be assumed to meet these requirements. 9. Water -heating equipment must be provided with controls that allow the user to set the water temperature to 110 degrees F for dwelling units and 90 degrees F for other occupancies. Controls must limit output temperatures of lavatories in public facility restrooms to 110 degrees F. 10. Stair and elevator shaft vents must be equipped with motorized dampers capable of being automatically closed during normal building operation and interlocked to open as required by fire and smoke detection systems. All gravity outdoor air supply and American Self Storage - Bldg. No. 1 Page 8 of 9 exhaust hoods, vents, and ventil�%/ must be equipped with motorized dampers that will alv,latically shut when the spaces served are not in use. Exceptions: - Gravity (non -motorized) dampers are acceptable in buildings less than three stories in height above grade. - Ventilation systems serving unconditioned spaces. American Self Storage - Bldg. No. 1 Page 9 of 9 on 0700387 COMcneck Software ver American Self Storage Addition Envelope ComK 2003 IECC Report Date: 08/09/07 Data filename: C:\Program Files\ChecMCOMcheck\Amemian Self Storage Building No. 4.cck Section 1: Project Information Project Title: American Self Storage Construction Site: Owner/Agent: Designer/Contractor: 270 American Street Danny Miller Tech -Fast Self Storage Buildings Rexburg , ID 83440 American Self Storage 615 Commerce Street 270 American Street Tacoma, WA 98402 Rexburg, ID 83440 253-572-4440 208-656-9911 Section 2: General Information Building Location (for weather data): Rexburg, Idaho Climate Zone: 16 Heating Degree Days (base 65 degrees F): 8693 Cooling Degree Days (base 65 degrees F): 143 Project Type: New Construction Vertical Glazing / Wall Area Pct.: 0% Building Type Storage, Industrial and Commercial Section 3: Requirements Checklist a> Floor Area 11400 Climate -Specific Requirements: Component Name/Description Gross Area Cavity Cont. Proposed Budget or Perimeter R-Value R-Value U-Factor U-Factor Roof 1: Metal Roof without Thermal Blocks 11400 0.0 19.0 0.051 0.047 Exterior Wall 1: Metal Frame, 16" o.c. 7052 0,0 11.0 0.075 0.067 Interior Wall 1: Metal Frame, 24" c.c. 3268 0.0 11.0 0.073 0.112 Floor 1: Slab-On-Grade:Unheated, Vertical 3 ft. 821 --- 0.0 -- -- (a) Budget U-factors are used for software baseline calculations ONLY, and are not code requirements Air Leakage, Component Certification, and Vapor Retarder Requirements: Ft 1. All joints and penetrations are caulked, gasketed or covered with a moisture vapor -permeable wrapping material installed in accordance with the manufacturer's installation instructions. 2. Windows, doors, and skylights certified as meeting leakage requirements. Lj 3. Component R-values & U-factors labeled as certified. 1-1 4. Insulation installed according to manufacturer's instructions, in substantial contact with the surface being insulated, and in a manner that achieves the rated R-value without compressing the insulation. 5. Stair, elevator shaft vents, and other dampers integral to the building envelope are equipped with motorized dampers. 6. Cargo doors and loading dock doors are weather sealed. 7. Recessed lighting fixtures are: (i) Type IC rated and sealed or gasketed; or (ii) installed inside an appropriate air -tight assembly with a 0.5 inch clearance from combustible materials and with 3 inches clearance from insulation material. American Self Storage Bid. No. 4 Page 1 of 7 Lj 8. Building entrance doors have a�eibule and equipped with closing devices. llq� Exceptions: Building entrances with revolving doors. Doors that open directly from a space less than 3000 sq. ft. in area. 9. Vapor retarder installed. Section 4: Compliance Statement Compliance Statement: The proposed envelope design represented in this document is consistent with the building plans, specifications and other calculations submitted with this permit application. The proposed envelope system has been designed to meet the 2003 IECC requirements in COMcheck Version 3.4.2 and to comply with the mandatory requirements in the Requirements Checklist. Name - Title Signature Date American Self Storage Bld. No. 4 Page 2 of 7 fF r` COMcheck Software Version 3.4.2 Lighting Compliance Certificate 2003 IECC Report Date: 08/09/07 Data filename: C:\Program Files\ChecMCOMcheckWmemian Self Storage Building No. 4.cck Section 1: Project Information Project Title: American Self Storage Bid. No. 4 Construction Site: Owner/Agent: Designer/Contractor: 270 American Street Danny Miller Tech -Fast Self Storage Buildings Rexburg, ID 83440 American Self Storage 615 Commerce Street 270 American Street Tacoma, WA 98402 Rexburg, ID 83440 253-572-4440 208-656-9911 Section 2: General Information Building Use Description by: Project Type: New Construction Building Tvge Floor Area Storage, Industrial and Commercial 11400 Section 3: Requirements Checklist Interior Lighting: 1. Total actual wafts must be less than or equal to total allowed watts. Allowed Watts Actual Wafts Complies 9120 800 YES Cj 2. Exit signs 5 Watts or less per side. Exterior Lighting: 3. Efficacy greater than 45 lumens/W. Exceptions: Specialized lighting highlighting features of historic buildings; signage; safety or security lighting; low -voltage landscape lighting. Controls, Switching, and Wiring: 4. Independent controls for each space (switch/occupancy sensor). Exceptions: Areas designated as security or emergency areas that must be continuously illuminated. Lighting in stairways or corridors that are elements of the means of egress. Fi 5. Master switch at entry to hotel/motel guest room. ❑ 6. Individual dwelling units separately metered. 7. Each space provided with a manual control to provide uniform light reduction by at least 50%. Exceptions: Only one luminaire in space; An occupant -sensing device controls the area; The area is a corridor, storeroom, restroom, public lobby or guest room; Areas that use less than 0.6 Watts/sq.fl. American Self Storage Bid. No. 4 Page 3 of 7 8. Automatic lighting shutoff contr%buildings larger than 5,000 sq.ft. Exceptions: Areas with only one luminaire, corridors, storerooms, restrooms, or public lobbies. 9. Photocell/astronomical time switch on exterior lights. Exceptions: Lighting intended for 24 hour use. 10.Tandem wired one -lamp and three -lamp ballasted luminaires (No single -lamp ballasts). Exceptions: Electronic high -frequency ballasts; Luminaires on emergency circuits or with no available pair. Section 4: Compliance Statement Compliance Statement: The proposed lighting design represented in this document is consistent with the building plans, specifications and other calculations submitted with this permit application. The proposed lighting system has been designed to meet the 2003 IECC, Chapter 8, requirements in COMcheck Version 3.4.2 and to comply with the mandatory requirements in the Requirements Checklist. Name - Title Signature Date American Self Storage Bld. No. 4 Page 4 of 7 C(7Mcheck Software Version 3.4.2 Lighting Application Worksheet 2003 IECC Report Date: Data filename: C:\Program Files\Check\COMchec0Amercian Self Storage Building No. 4.cck Section 1: Allowed Lighting Power Calculation A B C D Floor Area Allowed Allowed Watts Watts 1ft2 Storage. Industrial and Commercial 11=00 0.8 9120 Total Allowed Watts = 9120 Section 2: Actual Lighting Power Calculation A B C D E Fixture ID :Description / Lamp/ Wattage Per Lamp I Ballast Lamps/ # of Fixture (C X D) Fixture Fixtures Waft. Storage, Industrial and Commercial (11400 sq.ft.) HID 1: Metal Halide 100W / Electronic 1 8 100 800 Total Actual Watts = 800 Section 3: Compliance Calculation If the Total Allowed Watts minus the Total Actual Watts is greater than or equal to zero, the building complies. Total Allowed Watts = 9120 Total Actual Watts = 800 Project Compliance = 8320 American Self Storage Bid. No. 4 Page 5 of 7 COMcheck Software Version 3.4.2 nv Mechanical Compliance Certificate 2003 IECC Report Date: 08/09/07 Data filename: C:\Program Files\Check\COMcheck\Amercian Self Storage Building No. 4.cck Section 1: Project Information Project Title: American Self Storage Bld. No. 4 Construction Site: Owner/Agent: 270 American Street Danny Miller Rexburg . ID 83440 American Self Storage 270 American Street Rexburg, ID 83440 208-656-9911 Section 2: General Information Building Location (for weather data): Rexburg, Idaho Climate Zone: 16 Heating Degree Days (base 65 degrees F): 8693 Cooling Degree Days (base 65 degrees F): 143 Project Type: New Construction Section 3: Mechanical Systems List Quantity System Type & Description Section 4: Requirements Checklist Designer/Contractor: Tech -Fast Self Storage Buildings 615 Commerce Street Tacoma, WA 98402 253-572-4440 American Self Storage Bld. No, 4 Page 6 of 7 C®Mcheck Software Version 3.4.2 a Mechanical Requirements Description 2003 IECC Report Date: Data filename: C:\Program Files\Check\COMcheck\Amercian Self Storage Building No. 4.cck American Self Storage Bld. No. 4 Page 7 of 7 COMcheck Software b Envelope Corr 0700387 American Self Storage Addition 2003 IECC Report Date: 08/13/07 Data filename: C:\Program Files\Check\COMcheck\Amencan Self Storage Building No. 5.cck Section 1: Project Information Project Title: American Self Storage Building No. 5 Construction Site: 270 American Street Rexburg, ID 83440 Owner/Agent: Danny Miller American Self Storage 270 American Street Rexburg, ID 83440 208-656-9911 Section 2: General Information Building Location (for weather data): Rexburg, Idaho Climate Zone: 16 Heating Degree Days (base 65 degrees F): 8693 Cooling Degree Days (base 65 degrees F): 143 Project Type: New Construction Vertical Glazing / Wall Area Pct.: 0 Building Type Storage, Industrial and Commercial Section 3: Requirements Checklist Floor Area 9900 Designer/Contractor: Tech -Fast Self Storage Buildings 615 Commerce Street Tacoma, WA 98402 253-572-4440 Climate -Specific Requirements: Component Name/Description Gross Area Cavity Cont. Proposed Budget or Perimeter R-Value R-Value U-Factor U-Factor Roof 1: Metal Roof without Thermal Blocks 9900 0.0 19.0 0.051 0.047 Extenor Wall 1: Metal Frame, 16' o.c. 6192 0.0 11.0 0.075 0.067 Door 1: Solid 30 0.060 0.112 Door 2: Solid 30 -- --- 0.060 0.112 Door 3: Solid 30 --- -- 0.060 0.112 Door 4: Solid 30 -- -- 0.060 0.112 Interior Wall 1: Metal Frame, 24" o.c. 9014 0.0 11.0 0.073 0.112 (a) Budget U-factors are used for software baseline calculations ONLY, and are not code requirements Air Leakage, Component Certification, and Vapor Retarder Requirements: 1. All joints and penetrations are caulked, gasketed or covered with a moisture vapor -permeable wrapping material installed in accordance with the manufacturer's installation instructions. ❑ 2. Windows, doors, and skylights certified as meeting leakage requirements. ❑ 3. Component R-values & U-factors labeled as certified. ❑ 4. Insulation installed according to manufacturers instructions, in substantial contact with the surface being insulated, and in a manner that achieves the rated R-value without compressing the insulation. 5. Stair, elevator shaft vents, and other dampers integral to the building envelope are equipped with motorized dampers. American Self Storage Building No. 5 Page 1 of 7 6. Cargo doors and loading dock 6%wP9 are weather sealed. 114WW ❑ 7. Recessed lighting fixtures are: (i) Type IC rated and sealed or gasketed; or (ii) installed inside an appropriate air -tight assembly with a 0.5 inch clearance from combustible materials and with 3 inches clearance from insulation material. Lj 8. Building entrance doors have a vestibule and equipped with closing devices. Exceptions: Building entrances with revolving doors. Doors that open directly from a space less than 3000 sq. ft. in area. ❑ 9. Vapor retarder installed. Section 4: Compliance Statement Compliance Statement: The proposed envelope design represented in this document is consistent with the building plans, specifications and other calculations submitted with this permit application. The proposed envelope system has been designed to meet the 2003 IECC requirements in COMcheck Version 3.4.2 and to comply with the mandatory requirements in the Requirements Checklist. Name - Title Signature Date American Self Storage Building No. 5 Page 2 of 7 COMcheck Software Version 3.4.2 Lighting Compliance Certificate 2003 IECC Report Date: 08/13/07 Data filename: C:\Program Files\Check\COMcheck\American Self Storage Building No. 5.cck Section 1: Project Information Project Title: American Self Storage Building No. 5 Construction Site: Owner/Agent: Designer/Contractor: 270 American Street Danny Miller Tech -Fast Self Storage Buildings Rexburg, ID 83440 American Self Storage 615 Commerce Street 270 American Street Tacoma, WA 98402 Rexburg, IO 83440 253-572-4440 208-656-9911 Section 2: General Information Building Use Description by: Project Type: New Construction Building Type Floor Area Storage, Industrial and Commercial 9900 Section 3: Requirements Checklist Interior Lighting: Fl 1. Total actual watts must be less than or equal to total allowed watts. Allowed Wafts Actual Watts Complies 7920 598 YES 2. Exit signs 5 Watts or less per side. Exterior Lighting: ❑ 3. Efficacy greater than 45 lumens/W. Exceptions: Specialized lighting highlighting features of historic buildings; signage; safety or security lighting; low -voltage landscape lighting. Controls, Switching, and Wiring: U 4. Independent controls for each space (switch/occupancy sensor). Exceptions: Areas designated as security or emergency areas that must be continuously illuminated. Lighting in stairways or oonidors that are elements of the means of egress. [-1 5. Master switch at entry to hotel/motel quest room. ci 6. Individual dwelling units separately metered. ❑ 7. Each space provided with a manual control to provide uniform light reduction by at least 50%. Exceptions: Only one luminaire in space; An occupant -sensing device controls the area; The area is a corridor, storeroom, restroom, public lobby or guest room; Areas that use less than 0.6 Watts/sq.ft. American Self Storage Building No. 5 Page 3 of 7 Lj 8. Automatic lighting shutoff contr6+lbuildings larger than 5,000 sq.ft. llq� Exceptions: Areas with only one luminaire, corridors, storerooms, restrooms, or public lobbies. O 9. Photocell/astronomical time switch on exterior lights. Exceptions: Lighting intended for 24 hour use. jj 10.Tandem wired one -lamp and three -lamp ballasted luminaires (No single -lamp ballasts). Exceptions: Electronic high -frequency ballasts; Luminaires on emergency circuits or with no available pair. Section 4: Compliance Statement Compliance Statement: The proposed lighting design represented in this document is consistent with the building plans, specifications and other calculations submitted with this permit application. The proposed lighting system has been designed to meet the 2003 IECC, Chapter 8, requirements in COMcheck Version 3.4.2 and to comply with the mandatory requirements in the Requirements Checklist. Name - Title Signature Date American Self Storage Building No. 5 Page 4 of 7 COMcheck Software Version 3.4 2 Lighting Application Worksheet 2003 IECC Report Date: Data filename: C:\Program Files\Check\COMcheckWmedcan Self Storage Building No. 5.cck Section 1: Allowed Lighting Power Calculation A B c D Floor Area Allowed Allowed Watts Watts I ft2 Storage, Industrial and Commercial 9900 0.8 7920 Total Allowed Watts = 7920 Section 2: Actual Lighting Power Calculation A B C D E Fixture ID : Description / Lamp I Wattage Per Lamp I Ballast Lamps/ # of Fixture (C X D) Fixture Fixtures Watt. Storage, Industrial and Commercial (9900 sq.fL) Linear Fluorescent 1: 36" T8 25W / Electronic 2 26 23 598 Total Actual Watts = 598 Section 3: Compliance Calculation If the Total Allowed Watts minus the Total Actual Watts is greater than or equal to zero, the building complies. Total Allowed Watts = 7920 Total Actual Watts = 598 Project Compliance = 7322 American Self Storage Building No. 5 Page 5 of 7 CCMcheck Software Version 3.4.2 Mechanical Compliance Certificate 2003 IECC Report Date: 08/13/07 Data filename: C:\Program Files\Check\COMcheck\Amedcan Self Storage Building No. 5.cck Section 1: Project Information Project Title: American Self Storage Building No. 5 Construction Site: Owner/Agent: Designer/Contractor: 270 American Street Danny Miller Tech -Fast Self Storage Buildings Rexburg, ID 83440 American Self Storage 615 Commerce Street 270 American Street Tacoma, WA 98402 Rexburg, ID 83440 253-572-4440 208-656-9911 Section 2: General Information Building Location (for weather data): Rexburg, Idaho Climate Zone: 16 Heating Degree Days (base 65 degrees F): 8693 Cooling Degree Days (base 65 degrees F): 143 Project Type: New Construction Section 3: Mechanical Systems List Quantity System Type 8 Description Section 4: Requirements Checklist American Self Storage Building No. 5 Page 6 of 7 C®Mcheck Software Version 3.4.2 Mechanical Requirements r Description 2003 IECC Report Date: Data filename: C:\Program Files\Check\COMcheck\American Self Storage Building No. 5.cck American Self Storage Building No. 5 Page 7 of 7