Index to Calculations
Item
Basis For Design
Design Loads
Foundation Plans
Foundation Point Loads
Design of Slab and Turndown
07 00387
American Self Storage Addition
D ECE�'ti��1'I
AUG 1 5 25"1
Project Engineer Robert E. Chambers
S.E. CONSULTANTS, INC.
5800 East Thomas Road, Suite 104
Scottsdale, Arizona 85251
(480) 946-2010 Fax: (480) 946-1909
BASIS FOR DESIGN
DEAD LOADS Roof Panels actual
LIVE LOADS
Roofs 20.0 psf., (Snow)
LATERAL
Wind Wind Load Basis: 90 mph
Exposure: C
Seismic Use Group: I
Seismic Design Cat: C
CODE: 2003 International Building Code
2001 Edition of Cold -Formed Steel Design Manual
STRESSES OF MATERIALS
CONCRETE
Footings f c = 2500 psi.
STEEL
Reinforcing
fy =
60000 psi. A-615, Grade 60
Weldable Reinforcing
fy =
60000 pal. A-706, Grade 60
Roof Deck
fy =
80000 psi. A-653, Grade 80
Cold formed Steel
fy =
55000 psi. A-653, Grade 55
SOIL
Allow. Soil Bearing Allow. LaL Bearing
1500 psf 150 psf / ft
Structural Wide Flange fy = 36000 psi. A-36 or
fy = 50000 psi. A-572
Tube fy = 46000 psi. A-500
Pipe fy = 36000 psi. A-501
PRELIMINARY UNLESS SEALED ON EACH SHEET OR ON COVER SHEET
Job: Date: 0 By: tZC, Job No.: 1689-01' SH..
S.E. CONSULTANTS, INC.
DESIGN WIND LOADS FOR PITCHED FREE ROOFS 2003 International Building Code
V, wind speed = 90 mph
Exposure Category = C
0, roof angle = 1.2 °
h, mean roof height = 8.64 ft
Main Wind Force Resisting System, ASCE7 6.5.13
KZ, exposure coeff.
= 0.85
Ke, topography factor
= 1.00
Kd, directionality factor
= 0.85
Iw, wind factor
= 1.00
G, gust effect factor
= 0.85
P = gzGCN
= 12.73 (CN) psf
ASCE7 6.5.6.6, Table 6-3
ASCE7 6.5.7.2, Figure 6-4
ASCE7 6.5.4.4, Table 6-4
ASCE7 6.5.5, Table 6-1
ASCE7 6.5.8
0.00256KZKZTKoV2lwGCN, Eq. 6-25
Roof
Angle, 0
Load Case
Wind Direction, y = 0°, 180°
Clear Flow
Obstructed
Flow
CNw
CND
CN`N
CNL
7.50
A
1.1
-0.3
-1.6
-1
B
0.2
-1.2
-0.9
-1.7
150
A
1.1
-0.4
-1.2
-1
B
0.1
-1.1
-0.6
-1.6
22.50
A
1.1
0.1
-1.2
-1.2
B
-0.1
-0.8
-0.8
-1.7
300
A
1.3
0.3
-0.7
-0.7
B
-0.1
-0.9
-0.2
-1.1
37.50
A
1.3
0.6
-0.6
-0.6
B
-0.2
-0.6
-0.3
-0.9
450
A
1.1
0.9
1 -0.5
-0.5
B
1 -0.3
-0.5
1 -0.3
1 -0.7
1 inandw lnhamnlaharf rnia-Mrienfs from ASUEZ Houre b-IMB
1.2
A
1.20
0.30
-0.50
-1.20
B
-1.10
-0.10
-1.10
-0.60
Is flow obstructed (Yes/No)?
Yes
Load Case A
P, windward roof
= -6.37 psf
P, leeward roof
= -15.28 psf
Load Case B
P. windward roof
= -14.01 psf
P, leeward roof
= -7.64 psf
PRELIM IN AItY U N LESS SEALEoD O N EACH S/�H EET O ItON CO VER SHEET
o b: � D ate: v j- By: ReC Job No.: 1689-0.1 S H
S.E. CONSULTANTS, INC.
BCD 9CS
• DESIGN WIND LOADS FOR PITCHED FREE ROOFS 2003 International Building Code
Wand Direction
V, wind speed = 90 mph
r = oc° is0° P'"'" P"" Exposure Category = C
0, roof angle = 1.2 °
a h, mean roof height = 8.52 ft
h
L
Main Wind Force Resisting System. ASCE7 6.5.13
KZ, exposure coeff. = 0.85 ASCE7 6.5.6.6, Table 6-3
Kn, topography factor = 1.00 ASCE7 6.5.7.2, Figure 6-4
Kd, directionality factor = 0.85 ASCE7 6.5.4.4, Table 6-4
1w, wind factor = 1.00 ASCE7 6.5.5, Table 6-1
G, gust effect factor = 0.85 ASCE7 6.5.8
P = gzGCN = 12.73 (CN) psf 0.00256KZKZTKOV21WGCN, Eq. 6-25
Roof
Angle, 0
Load Case
Wind Direction, y = 0°, 180"
Clear Flow
Obstructed
Flow
CNW
CNL
CNW
CNL
7.50
A
1.1
-0.3
-1.6
-1
B
0.2
-1.2
-0.9
-1.7
150
A
1.1
-0.4
-1.2
-1
B
0.1
-1.1
-0.6
-1.6
22.50
A
1.1
0.1
-1.2
-1.2
B
-0.1
-0.8
-0.8
-1.7
300
A
1.3
0.3
-0.7
-0.7
B
-0.1
-0.9
-0.2
-1.1
37.50
A
1.3
0.6
-0.6
-0.6
B
-0.2
-0.6
-0.3
-0.9
450
A
1 1.1
0.9
1 0.5
-0.5
B
1 -0.3
1 -0.5
1 -0.3
1 -0.7
I inandy Intarnnlatprl CnPttirlAnLS tmm ASC:C/ MCIU a ti-MH
1.2
A
1.20
0.30
A.50
-1.20
B
-1.10
-0.10
-1.10
-0.60
Is flow obstructed (Yes/No)?
Yes
Load Case A
P, windward roof
= -6.37 psf
P. leeward roof
= -15.28 psf
Load Case B
P, windward roof
= -14.01 psf
P, leeward roof
= -7.64 psf
PRELIMINARY
U N LESS SEALED ON
EACH
SHEET OR ON
COVER SHEET
Job: 1'z380
D ate: 80
By:
&C job No..
)10 -OT SH ..
S.E. CONSULTANTS, INC.
International Building Code - 2003
be-D /
Soil Site Class
Seismic Use Group
Ss -
St -
Fa =
=D
=1
16.8 %
8.2 %
Is]
Site Class
Tattle 1615.1.2 (1) (Fa)
Mapped spectral response acceleration at short periods (Ss)
0.25 0.50 0.75 1.00 1.25
A
0.80
0.80
0.80
0.80
0.80
B
1.00
1.00
1.00
1.00
1.00
C
1.20
1.20
1.10
1.00
1.00
D
1.60
1.40
1.20
1.10
1.00
E
2.50
1.70
1.20
0.90
0.90
FI-
-
-
-
-
1.600 (interpolated) Sms = Fa * Ss = 0.269
Site Class
Table 1615.1.2 (2) (Fv)
Mapped spectral response acceleration at 1 sec. periods (S1)
0.10 0.20 0.30 0.40 0.50
A
0.80
0.80
0.80
0.80
0.80
B
1.00
1.00
1.00
1.00
1.00
C
1.70
1.60
1.50
1.40
1.30
D
2.40
2.00
1.80
1.60
1.50
E
3.50
3.20
2.80
2.40
-
F
I -
-
-
I -
I -
Fv = 2.4 (interpolated)
Sas= 213*Sas= 0.179
Sds
>
Seismic Use Group
I If III
0.000
A
A A
0.167
B
B C
0.330
C
C D
0.500
ID
D D
Seismic Design Category = B
SMi = Fv * Si = 0.197
Six = 213*Smi=
0.131
Sdi
Seismic Use Group
>
I II [II
0.000
A
A A
0.067
B
B C
0.133
C
C D
0.200
D
D D
PRELIMINARY UNLESS SEALED ON EACH SHEET OR ON COVER SHEET
Job: Y&363 Date: 8 0* By: CJob No.. %4�"0T SH.. Al
S.E. CONSU LTANTS, INC.
Earthquake Lateral/Longitudinal Load to Column - 2003 IBC
Seismic Use Group -
I
Seismic Design Category -
B
1 -
1.00
Ss -
16.80 %
St -
8.20 %
SMs -
0.269
SMt -
0.197
R -
2.50
Height -
8.9 fl
T = 0.035' (hn)" 0.75 -
0.180
r Rellab111ty/redundancy Factor -
1.00
Sos -
0.179
SDI -
0.131
(16-35)
(16-36)
V = Sns / [Rll] - 0.072 W
V = SDI / [(R/l)T] - 0.291 W
(16-37)
V = 0.044' Si / [RII] - 0.001 W
(16-38)
V = 0.5' Si 1 [Rli] - 0.000 W
V (Controls) - 0.072 W kips
PRELIMINARY UNLESS SEALED ON EACH SHEET OR ON COVER SHEET
Job: ..T2383 Date: (910* By: P��. Job No.: J1o8Q 01- SH..
S.E. CONSULTANTS, INC.
International Building Code - 2003
136D "_5 -l' ,c' 5
Soil Site Class
Seismic Use Group
Ss -
S1 -
Fa =
=D
=1
16.8 %
8.2 %
O.K.
Site Class
Table 1615.1.2 (1) (Fa)
Mapped spectral response acceleration at short periods (Ss)
0.25 0.50 0.75 1.00 1.25
A
0.80
0.80
0.80
0.80
0.80
B
1.00
1.00
1.00
1.00
1.00
C
1.20
1.20
1.10
1.00
1.00
D
1.60
1.40
1.20
1.10
1.00
E
2.50
1.70
1.20
0.90
0.90
F
I -
I -
I -
I -
I -
1.600 (interpolated) SMs = Fa * Ss = 0.269
Site Class
Table 1615.1.2 (2) (Fv)
Mapped spectral response acceleration at 1 sec. periods (Si)
0.10 0.20 0.30 0.40 0.50
A
0.80
0.80
0.80
0.80
0.80
B
1.00
1.00
1.00
1.00
1.00
C
1.70
1.60
1.50
1.40
1.30
D
2.40
2.00
1.80
1.60
1.50
E
3.50
3.20
2.80
2.40
-
F
-I
-
I -
I -
I -
Fv = 2.4 (interpolated)
Scs = 213 * Sms = 0.179
Sds
>
Seismic Use Group
1 II III
0.000
A A A
0.167
B B C
0.330
C C D
0.500
ID D D
Seismic Design Category = B
SM1= Fv * Si = 0.197
Sw 213*Smi= 0.131
Sdi
>
Seismic Use Group
I 1 II 1 III
0.000
A A A
0.067
B B C
0.133
C C D
0.200
ID D D
PRELIMINARY UNLESS SEALED ON EACH SHEET OR ON COVER SHEET
Job: ye,305 Date: 8 By: C Job No.. %�,89-0 4 SH.. 10
S.E. CONSULTANTS, INC.
f Earthquake Lateral/Longitudinal Load to Column - 2003 IBC
Seismic Use Group -
I
Seismic Design Category -
B
1 -
1.00
Ss -
16.80 %
S1 -
8.20 %
SMs =
0.269
SM1 =
0.197
R -
2.50
Height -
8.67 ft
T = 0.035 • (hn)^0.75 -
0.177
r Reliability/redundancy Factor -
1.00
Sos -
0.179
Sol -
0.131
(16-35)
V = Sos / [Rll] - 0.072 W
(16-36)
V = Sri / [(R/l)T] - 0.297 W
(16-37)
V = 0.044' Si / [R/1] = 0.001 W
(16-38)
V = 0.5 " Si / [R/1] - 0.000 W
V (Controls) - 0.072 W kips
PRELIMINARY UNLESS SEALED ON EACH SHEET OR ON COVER SHEET
job: C 3 Date: (90, By: j?JL4r, job No.: /4009-o-1 SH..
S.E. CONSULTANTS, INC.
�2
MIN
/,500 P--p
PjX = 5 P�-P ( 4WF RAM# Nc, )
PLL = 35 P-p (:5NWLonU)
PTO r q L
AN. W!wrH OF CANT, -FTC,
/SQp
0.2.8 1 - = 3.4/n
�14 e, ry d� Raxsucok- 4*i ". / Z " D60"v f /Z
W ta>o" O/ *44e. #o07'~I/VClZ
Wot s*' CASE 4:a to LoAD
25. o} ( ,o r-T/Z Coo Ps = 5, 000, o
3"
I C 21 a 4 coN-r.
iZ "
PRELIMINARY UNLESS SEALED ON EACH SHEET OR ON COVER SHEET
Job: 12383 Date: 8/0'f By: FAA Job No.: 1689- 0; SH.: �S
S.E. CONSULTANTS, INC.
SE Consultants
Interior Columns
Roof
DL = 5 psf
LL = 35 psf
Mini Storage Point Loads
Width x Length = Area
5 10 50 ft"2
8/2/2007
PDL(roon = 250 Ibs
PLL(roon = 1750 lbs
P(TOTAL) = 2000 Ibs
Endwall Columns
Roof
DL = 5 psf
LL = 35 psf
Width x
5
Length
5
= Area
25 ft^2
PDL(rooO =
PLL(rooG =
P(ToTAL) = 1000
125
875
Ibs
Ibs
Ibs
Sidewall Columns
Roof
DL = 5 psf
Width x
Length
= Area
PDL(root) =
125
Ibs
LL = 35 psf
2.5
10
25 ft^2
PLL(roon =
875
Ibs
P(TOTAL) = 1000
Ibs
Interior Columns
Roof
DL = 5 psf
Width x
Length
= Area
PDL(roon =
250
Ibs
LL = 35 psf
5
10
50 ft"2
PLL(=() =
1750
Ibs
P(TOTAL) = 2000
Ibs
PRELIMINARY
j o b: ..I"2�J_.�
UNLESS SEALED O N EACH SHEET O R ON
D ate: 8 0 B y: G� ) o b N o ..
COVER SHEET
14 9-0* S H
S.E. CONSULTANTS, INC.
B
c
I
Pol Wr � .
vc
= Jos p = 8� LL
F(C:'r v I A L [3Ny RJR
Iq 18 (347) -= / z
PC'ruAL J3ejq&jm(& (Zjqpj3Cj,,r,,f
J, QOQ �6s
9.0 Fr?-" (/,r as)
OL
PRELIMINARY UNLESS SEALED ON EACH SHEET OR ON COVER SHEET
Job: Date: 6 By: Job No.: /689-0-1 SH.: /9
S.E. CONSULTANTS, INC.
d R LLUWAZLf, POINT BCA0 N C,
/ \ I� I �
for
2 Fr
AVER = (1 ') ( Z') z z FT z
30000 s �,C ✓
11s (m,N.) - Co.ao2-)(12 1N)(12. IN). = 0.2 88,ivz
a(0.Z jNz) = 0.4,m c
#4,
w / 0) # 4 6'°t, C7bp
PRELIMINARY UNLESS SEALED ON EACH SHEET OR ON COVER SHEET
Job: 12383 Date: 810T By: Job No.: 11*89.4+ SH.: ! �O
S.E. CONSULTANTS, INC.
d )CjEe//)2Z7 c, 'I G,4Mzx),J-,v
MIN CONCefTf-, Sc-AB OVElCG
A " A%8.G. 1:ku.
Li 1.4 x 0 /.-4
W. b). v, C€,wr cLu
XW 3 lR $
4 fiAe� �70 '
I--p �; bo-rtorn
f qAx. LORD : (S ") C25 ) (40. o pa-r)
�s 3 pr
= (isa0 Pcwr)(bFrZ)
Q,C 00 ibs or ✓
(mim.) = (o.00z ") (3&"+ 4 "')oz ") = o.910o,"z
(4) It 4 bx,--h = ( 0. 4 , w L") (4) -m A ep 04 v
PRELIMINARY UNLESS SEALED ON EACH SHEET OR ON COVER SHEET
Job: xZ383 Date: 8/04 By: ftC Job No.: 1489-04 SH.: Il
S.E. CONSULTANTS, INC.
W
SQUARE SPREAD FOOTING SCHEDULE
Soil Pressure = 1,500 PSF
Concrete - fc = 2500 PSI
Reinforcing - Grade 60
Mark
Footing
Size
SQ)
Thickness
of Footing
(IN)
Reinforcing
(3" CLR
Bottom
Allowable
Load, TL
(K
F-1
2'-0"
10
2- #4
6.0
F-2
20-6"
10
3- #4
9.4
F-3
T-0"
12
3- #5
13.5
F4
31-6"
12
4- #5
18.4
F-5
4'-0"
12
4- #5
24.0
F-6
41-6"
12
5- #5
30.4
F-7
5'-0"
12
4- #6
37.5
F-8
5'-6"
12
6- #6
45.4
F-9
6'-0"
14
6- #6
54.0
F-10
61-6"
14
7- #6
63.4
Notes:
1) Ref. ACI 318-89/318R-89, Strength Design Method
PRELIMINARY UNLESS SEALED ON EACH SHEET OR ON COVER SHEET
Job: 1Z.383
Date: 4 By: UC Job No.: /689-0-'�SH.: 28
. S.E. CONSULTANTS, INC.