SHORT FORM - 07-00341 - 2550 S 4000 W - New SFR Mechanical
Shorti-arm Entire House Job: 1 - 07 00341 2550 S 4000 W-Sanderson Project For: Sanderson Residence Rexburg, Idaho 83440 Design Information Htg Clg Infiltration Outside db (OF) -6 89 Method Simplified Inside db (OF) 70 75 Construction quality Average Design TD (OF) 76 14 Fireplaces 0 Daily range - H Inside humidity (%) 50 Moisture difference (grAb) -31 HEATING EQUIPMENT Make AmStd Trade Freedom 90 Model AUC100C948B` Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 92.1 AFUE 100000 Btuh 94000 Btuh 80 OF 1266 cfm 0.020 cfm/Btuh 0.80 in H2O COOLING EQUIPMENT Make AmStd Trade Allegiance 14 Cond 2A7A4048A1 Coil TXC048C4+BAY24XO45 Efficiency 13 SEER Sensible cooling 33250 Btuh Latent cooling 14250 Btuh Total cooling 47500 Btuh Actual air flow 1266 cfm Air flow factor 0.044 cfm/Btuh Static pressure 0.80 in H2O Load sensible heat ratio 1.00 ROOM NAME Area (fl2) Htg load (Btuh) Clg load (Btuh) Htg AVF (cfm) Clg AVF (cfm) bed 1 210 4310 1345 87 59 bath 90 1559 770 31 34 bed 2 212 5048 2229 101 98 bed 3 180 3317 1980 67 87 entry 88 2735 1106 55 49 great room 460 6507 2698 131 119 office 156 4530 1816 91 80 hall 230 0 0 0 0 utility 98 3006 2341 60 103 bonus 532 12507 2027 251 90 kitchen/dining 469 8399 6909 169 305 privacyjohn 16 315 93 6 4 mas clst. 56 0 0 0 0 mas bath 168 3213 1563 64 69 mas bed 315 7628 3795 153 168 .o n n n n hall 110 S"JtWk values have been manually overridden Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wn9ht50'R Right-surte Residential 6.0.02 RSR40615 2007-May-24 16:23:41 ACCA DAWnghtsoft WACCave Sanderson QW5 with 400 bonus).np Cale = MJ8 Orientation = N Page 1 Entire House 3327 63076 28673 1266 1266 Other equip loads 6886 1268 Equip. @ 0.94 RSM 28145 Latent cooling 1 0 TOTALS ' 3327 ' 69961 ' 28145 ' 1266 ' 1266 Bold/helie values have been manually over iCtlen Printout certified by ACCA to meet all requirements of Manual J 8th Ed. ,ti WrIghtsoft RightSuHe Residential6.0.02RSR40615 200r-May-2416:23:41 ACM D:1WnghtsoR HVACtDave Sanderson (2695 with 400 bonus).np Calc = MJ8 Orientation = N Page 2 Buildil.y Analysis Entire House Job: 1 Date: May 24, 2007 By: J & B Heating LLC For: Location: Idaho Falls, ID US Elevation: 4' 411 ft Latitude: 44°N OutDry bulb (OF) Daily range F) Wet bulb (° Wind speed (mph) Sanderson Residence Rexburg, Idaho 83440 INEENE • • Heats g 9 Cooling - 334 (H ) 15.0 7.5 Component Btuh/ft2 Btuh % of load Walls 4.9 12923 18.5 Glazing 25.8 9160 13.1 Doors 45.6 2873 4.1 Ceilings 2.0 6270 9.0 Floors 2.1 6509 9.3 Infiltration 3.2 9640 13.8 Ducts 15701 22.4 Piping 0 0.0 Humidification 0 0.0 Ventilation 6886 9.8 Adjustments -0 Total 69961 100.0 Component Btuh/ft2 Btuh % of load Walls 0.5 1241 4.1 Glazing 16.8 5951 19.9 Doors 11.1 699 2.3 Ceilings 1.1 3465 11.6 Floors 0.3 986 3.3 Infiltration 0.3 951 3.2 Ducts 10630 35.5 Ventilation 1268 4.2 Internal gains Blower 4750 0 15.9 0.0 Adjustments 0 To9l 29941 100.0 Overall U-value = 0.155 Btuh/ft'--°F Data entries checked. Indoor: Indoor temperature (OF) Design TD (°F1 Relative humidity (%) Moisture difference (grfib) Heating 70 76 50 61.5 Cooling 75 14 50 -31.5 Infiltration: Method Construction quality Simplified Average Fireplaces 0 ads Awnghtsoft RigMSude Residential6.0.02RSR40615 2007-May-2416:23:41 A D9Wngmsoft HVAC\Dave Sanderson (2695 with 400 bonus).rrp Cak = MJ8 Orientation = N Page 1 Comps rient Constructions _ Job: 1 Date: May 24, 2007 Entire House By: J 8 B Heating LLC For: Sanderson Residence Rexburg, Idaho 83440 Location: Indoor: Heating Cooling Idaho Falls, ID, US Indoor temperature (°F) 70 75 Elevation: 4741 ft Design TD (°F) 76 14 Latitude: 440N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr1lb) 61.5 -31.5 Dry bulb (°F) -6 89 Infiltration: Daily range°F) - 34 (H) Method Simplified Wet bulb (°) - 60 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions or Area U-value Insul R Htg HTM Loss Clg HTM Gain (fF) (aWW F) (R FA h) (aWh4F) (BWh) (MhM9 (Mh) Walls 12F-Osw: Wood stud frame, siding or stucco, no board insulation, n 556 0,065 21.0 4.94 2747 0.47 264 R-21 cavity insulation a 717 0.065 21.0 4.94 3542 0.47 340 s 614 0.065 21.0 4.94 3033 0.47 291 w 718 0.065 21.0 4.94 3547 0.47 341 nw 11 0.065 21.0 4.94 54 0.47 5 all 2616 0.065 21.0 4.94 129M 0.47 1241 Partitions (none) Windows 61 A: vinyl clear low e, clear low-e; NFRC rated (SHGC=0.30) Doors 11 JO: Metal door, fiberglass core, no storm Ceilings 16B-38ad: Ceiling under vented attic, no radiant barrier, dark shingles, R-38 insulation Floors 20P-21 c: Carpeted floor over open crawVgarage, R-21 blanket insulation 19C-Ocwp: Carpeted floor over tight enclosed crawl, R-11 wall, No insul n 177 0.340 0.0 25.8 4574 10.5 1851 e 46 0.340 0.0 25.8 1189 32.8 1510 s 104 0.340 0.0 25.8 2687 18.3 1899 w 6 0.340 0.0 25.8 155 32.8 197 nw 22 0.340 0.0 25.8 556 23.0 494 all 355 0.340 0.0 25.8 9160 16.8 5951 s 42 0.600 0.0 45.6 1915 11.1 466 NY 21 0.6DD 0.0 45.6 958 11.1 233 all 63 0.600 0.0 45.6 2873 11.1 699 3173 0.026 38.0 1.98 6270 1.09 3465 378 0.047 21.0 3.57 1350 0.09 36 2795 0.36E 0.0 1.65 5158 0.34 950 wnghtsoft Right -Slide Rmiderdial6.0.02RSR40615 2007-May-2416:23:42 ACCA DAWnghtsoft HVAC\Daee Sanderson (2695 with 400 bonm).np Cale = MJ6 Orientation = N Page 1 Project-iummary Entire House Job: 1 '✓ Date: May 24, 2007 By: J 8 B Heating LLC Project Information For: Sanderson Residence Rexburg, Idaho 83440 Notes: Design• • Weather: Idaho Falls, ID, US Winter Design Conditions Summer Design Conditions Outside db -6 OF Outside db 89 OF Inside db 70 OF Inside db 75 OF Design TD 76 OF Design TD 14 OF Daily range H Relative humidity 50 % Moisture difference -31 gr/lb Heating Summary Sensible Cooling Equipment Load Sizing Structure 47374 Btuh Structure 18043 Btuh Ducts 15701 cfm Ducts 10630 Btuh Central vent (98 cfm) 6886 Btuh Central vent (98 cfm) 1268 Btuh Humidification 0 Btuh Blower 0 Btuh Piping 0 Btuh Equipment load 69961 Btuh Use manufacturer's data n Rate/swing multiplier 0.94 Infiltration Equipment sensible load 28145 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Average Fireplaces 0 Structure -322 Btuh Ducts -295 Btuh Heating Cooling Central vent 98 cfm) -1763 Btuh Area (f 2) 332g 3327 Equipment la ent load 0 Btuh Volume (ft3) 29411 29411 Air changes/hour 0.28 0.15 Equipment total load 28145 Btuh Equiv. AVF (cfm) 137 74 Req. total capacity at 0.70 SHR 3.4 ton Heating Equipment Summary Cooling Equipment Summary Make AmStd Make AmStd Trade Freedom 90 Trade Allegiance 14 g Model AUC100C948B- Cond 2A 4048A1 Coil TXC048C4+BAY24XO45 Efficiency 92.1 AFUE Efficiency 13 SEER Heating Input 100000 Btuh Sensible cooling 33250 Btuh Heating output 94000 Btuh Latent cooling 14250 Btuh Temperature rise 80 OF Total cooling 47500 Btuh Actual air flow 1266 cfm Actual air flow 1266 cfm Air flow factor 0.020 cfm/Btuh Air flow factor 0.044 cfm/Stuh Static pressure 0.80 in H2O Static pressure 0.80 in H2O Space thermostat Load sensible heat ratio 1.00 9old'ildw values have been manually overridden Printout certified by ACCA to meet all requirements of Manual J 8th Ed. t W"0h1tSC3 t RightSude Residential6.0.02RSR40615 2007-May-2416:23*42 Z?51k DAWrightsoh HVACVDave Sanderson (2695 with 400 bonus).up Cak = MA Onentabon = N Page 1 -- AED Assessment Entire House For: Sanderson Residence Rexburg, Idaho 83440 Job: 1 Date: May 24, 2007 By: J & B Heating LLC Design C• • • Location: Indoor: Heating Cooling Idaho Falls, ID, US Indoor temperature (T) 70 75 Elevation: 4741 It Design TD (T) 76 14 Latitude: 44°N Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 61.5 -31.5 Dry bulb (T) -6 89 Infiltration: Daily range (T) - 34 ( H) Method Simplified Wet bulb (T) - 60 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 M Hourly Glazing Load 8 9 10 11 12 13 14 15 16 17 18 19 20 Hour of Day r"�ouny Average AED:rnt Maximum hourly glazing load exceeds average by 29.3%. House has adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 0 Btuh 1 wnghtsoft Right-Sude Re identia16002RSR40615 2007-May-24 16 23:42 A 0r D:\Wdghtsofl HVAC\Dave Sanderson (2695 with 400 bonus)_np Cale = MJ8 Orientation = N Page 1 1 L Right_. Worksheet Entire House Job: 1 Date: May 24, 2007 By: J & B Heating LLC 1 Room name Entire House bed 1 2 Exposed wall 348.6 ft 29.0 ft 3 Ceiling height 8.8 It 9.0 It healccol 4 Room dimensions 14.0 x 15.0 ft 5 Room area 3327.0 ft' 210.0 W Ty Construction U-value Or HTM Area (fly Load Area (ft') Load number I (BtuhlR?'F) (Bluh/ft2) or perimeter (ft) (Bluh) or perimeter (it) (Btuh) Heat I Cod Gross I WP/S Heat Cool Gross PIP/S Heat Cool 6 Vy 12F-0sw 0.065 n 4.94 0.47 733 556 2747 264 126 111 548 53 t-C 61A 0.340 n 26.84 10.46 177 0 4574 1851 15 0 388 167 W 12F-0sw 0.065 a 4.94 0.47 763 717 3542 340 0 0 0 0 L-{3 61A 0.340 a 25.84 32.83 46 0 1189 1510 0 0 0 0 17 12F-0sw 0.065 s 4.94 0.47 760 614 3033 291 0 0 0 0 61A 0.340 s 25.64 18.26 104 0 2687 1899 0 0 0 0 11Jo 0.600 s 45.60 11.10 42 42 1915 466 0 0 0 0 W 12F-0sw 0.065 w 4.94 0.47 745 718 3547 341 135 135 667 64 61A 0.340 w 25.84 32.83 6 0 155 197 0 0 0 0 (�-GD 11Jo 0.600 w 45.60 11.10 21 21 958 233 0 0 0 0 lq! 12F-0sw 0.065 nw 4.94 OA7 32 11 54 5 0 0 0 0 t--G 61A 0.340 nw 25.84 22.98 22 0 556 494 0 0 0 0 C 168-38ad 0.026 - 1.98 1.09 3173 3173 6270 3465 210 210 415 229 F 20P-210 0.047 - 3.57 0.09 378 74 1350 36 0 0 0 0 F 19C-Ocscv 0.368 - 1.85 0.34 2795 245 5158 960 210 29 388 71 6 c) AED excursion 0 45 Envelope loss/gain 37734 12342 2405 530 12 a) Infiltration 9640 951 829 82 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 5 1150 1 230 Appliances @ 1200 3 3600 0 0 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -0 0 23 8 14 Subtotal 47374 18043 3258 850 15 Duct loads 33% 59%1 15701 10630 32% 58% 1063 495 Total room load 63076 28673 4310 1345 Air required (cfm) 1266 1 1266 87 59 Printout cer5fied by ACCA to meet all requirements of Manual J 8th Ed. wrtghtsoft RghtSuite Residenfial6.0.02 RSR40615 2007-May-2416:23:43 .4C2� DAWrightso8 HVAC1Dave Sanderson (2695 with 400 bonus).rrp Cato = MJ8 Orientation = N Pepe 1 E " ` Right Worksheet Job: 1 Entire House Date: May H 8y: J & B Heating LLC 1 Room name bath bed 2 2 Exposed wall 9.0 ft 32.0 ft 3 Ceiling height 9.0 ft he it/caol ao ft heat/cool 4 Room dimensions 10.0 x 9.0 ft 1.0 x 212.0 0 5 Room area 90.0 w 212.0 ft- Ty Construction U-value Or HTM Area (ft2) Load Area (W) Load number (BtuhTIMF) (BtuhW) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Coal Gross WP/S Heat Cool Gross 14/P/S Heat Cool 6 W 12F-Osw 0.065 n 4.94 0.47 0 0 0 0 0 0 0 0 61A 0.340 n 25.84 10.46 0 0 0 0 0 0 0 0 l(V 12F-Osw 0.066 a 4.94 0.47 0 0 0 0 18 18 89 9 --G 61A 0.340 a 25.94 32.83 0 0 0 0 0 0 0 0 11 l9J 12F-0sw 0.065 s 4.94 0.47 0 0 0 0 126 96 474 46 61A 0.340 s 25.84 18.26 0 0 0 0 30 0 775 548 t1---GD 11,10 0.6DO s 45.60 11.10 0 0 0 0 0 0 0 0 Vj/ 12F4sw 0.065 w 4.94 0.47 81 75 370 36 144 144 711 68 {-G 61A 0.340 w 25.64 32.83 6 0 155 197 0 0 D 0 j 11,10 0.600 w 45.60 11.10 0 0 0 0 0 0 0 0 y/ 12F-0sw 0.065 nw 4.94 0.47 0 0 0 0 0 0 0 0 `C 61A 0.340 nw 25.84 22.98 0 0 0 0 0 0 0 0 C 168-38ed 0.026 - 1.98 1.D9 90 90 178 98 212 212 419 232 F 2OP-21c 0.047 - 3.57 0.09 0 0 0 0 0 0 0 0 F 19Cdceep 0.368 - 1.85 0.34 90 9 166 31 212 32 391 72 6 c) AED excursion 81 100 Envelope loss/gain 8% 442 2860 1074 12 a) Infiltration 257 25 915 90 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 1 230 Appliances @ 1200 0 0 0 0 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 52 18 40 14 14 Subtotal 1178 486 3815 1409 1151 Duct (pads 32% 58% 381 283 32% 58% 1233 821 Total roam load 1559 770 1 5048 2229 Air required (ctm) 31 34 101 98 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wrsghCsoTt RightSude Residential6.0.02RSR40615 2007-May-2416:23,43 � -t` D:\Wdghtsoft HVAC\Dave Sanderson (2695 with 400 bonus)-np rate = MJ8 Orientation = N Page 2 Right_ Worksheet Entire House Job: 1 Date: May 24, 2007 By: J & 6 Heating LLC 1 Room name bed 3 entry 2 Exposed well 16.0 it 8.0 ft 3 Ceding height 9.0 ft heaN0001 9.0 ft heavcool 4 Room dimensions 12.0 x 15.0 ft 8.0 x 11.0 ft 5 Room area 180.0 w 88.0 W Ty Construction U-value Or HTM Area (ft-) Load Area (ft2) Load number I (Bluhf t' *F) (Btuh/ft) m perimeter (ft) (Btuh) or perimeter (ft) (Bluh) Heat Cool Gross WPIS Heat Cool Gross N/P/S Heal Cool 6 VLC12F-0sw 0.065 n 4.94 0.47 0 0 0 0 0 0 0 0 61A 0.340 n 25.84 10.46 0 0 0 0 0 0 0 0 Vy 12F-0sw 0.065 a 4.94 0.47 36 36 178 17 0 0 0 0 L--G 61A 0.340 a 25.84 32.83 0 0 0 0 0 0 0 0 11 12F-0sw 0.065 s 4.94 0.47 108 78 385 37 72 37 183 18 61A 0.340 s 25.84 18.26 30 0 775 548 14 0 362 256 11J0 0.600 s 45.60 11.10 0 0 0 0 21 21 958 233 Vj! 12F-0sw 0.065 w 4.94 0.47 0 0 0 0 0 0 0 0 �L�Da 61A 0.340 w 25.84 32.83 0 0 0 0 0 0 0 0 11Jo 0.600 w 45.60 11.10 0 0 0 0 0 0 0 0 11/ 12F-0sw 0.065 nw 4.94 0.47 0 0 0 0 0 0 0 0 L--a 61A 0.340 nw 25.84 22.98 0 0 0 0 0 0 0 0 C 165-38ad 0.026 - 1.98 1.09 180 180 356 197 88 88 174 96 F 20P-21c 0.047 - 3.57 0.09 0 0 0 0 0 0 0 0 F 19C-ocscp 0.368 - 1.85 0.34 180 16 332 61 88 8 162 30 6 c) AED excursion 108 44 Envelope loss/gain 2026 968 1838 677 12 a) Infiltration 458 45 229 23 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 0 0 Appliances @ 1200 0 0 0 0 Less exlemal load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 23 e 0 0 14 Subtotal 2507 1251 2067 699 15 Duct loads 32% 58% 810 7298 32% 58% 668 407 Total room load 3317 19N 2735 1106 Air required(cfm) 67 87 55 49 J 8th Ed. 'ii&wr-sght��R RightSude Residentia16.0.02 RSR40615 D.\W6nhtsoft HVAC\Dave Sanderson (2695 mth 400 bonus).np Calc= MJB Onentabon = N 2007-May-24 16:23:43 Page 3 "`°""' Righ... Worksheet Entire House Job: 1 Date: May 24, 2007 By: J & B Heating LLC 1 Room name great room office 2 Exposed wall 20.0 ft 21.0 ft 3 Ceiling height 9.0 It heatIcool 9.0 R heaVcool 4 Room dimensions 20.0 x 23.0 It 12.0 x 13.0 It 5 Room area 460.0 112 156.0 ft2 Ty Construction U-value Or HTM Ares (ft-) Load Area (W) Load number (Btuh/ft?-F) (Bluh/ft2) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Hest Cod Gross WPIS Heat Cool Gross WRIS Heat Cool 6 W 12F-Osw 0.065 n 4.94 0.47 180 108 534 51 0 0 0 0 L-G 61A 0.340 n 25.84 10.46 72 0 1860 753 0 0 0 0 Vy 12F-Osw 0.065 a 4.94 0.47 0 0 0 0 63 63 311 30 LC 61A 0.340 a 25.84 32.83 0 0 0 0 0 0 0 0 11 t9/ 12F-Osw 0.065 s 4.94 0.47 0 0 0 0 ID8 78 385 37 61A 0.340 s 25.84 18.26 0 0 0 0 30 0 775 548 LF-GD 11J0 0.6DO s 45.60 11.10 0 0 0 0 0 0 0 0 1�ff 12F-Osw 0.065 w 4.94 0.47 0 0 0 0 18 18 89 9 I--G 61A 0.340 w 25.84 32.83 0 0 0 0 0 0 0 0 III-----DDD 11J0 0.600 w 45.60 11.10 0 0 0 0 0 0 0 0 y/ 12F-Osw 0.065 my 4.94 0.47 0 0 0 0 0 0 0 0 t-G 61A 0.340 nw 25.84 22.98 0 0 0 0 0 0 0 0 C 16B-38ad 0.026 - 1.98 1.09 460 460 909 502 156 156 308 170 F 20P-21c 0.047 - 3.57 0.09 0 0 0 0 0 0 0 0 F 19C-00scp 0.368 - 1.85 0.34 460 20 849 156 156 21 288 53 6 c) AED excursion -88 120 Envelope losstgain 4152 1375 2157 966 12 a) Infiltration 572 56 601 59 b) Room ventilation 1 0 0 0 0 13 Internal gains: Occupants @ 230 1 230 0 0 Appliances @ 1200 0 0 0 0 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 194 43 666 122 14 Subtotal 4918 17D5 3424 1147 15 Dud loads 32% 58% 1589 993 32% 58%1 1106 669 Total room load 6507 2698 4530 1816 Air required (rim) 131 119 91 80 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wr7ght50ft RipMSuite Resiaential6.0.02 RSR40615 2007-May-2416:23:43 ACC D:%Wnghtsoft HVAC1Dave Sanderson (2695 with 400 bonus).np Cale = MJ8 Orientation = N Page 4 E 9I Right , Worksheet Entire House Job: 1 Date: May 24, 2007 By: J & B Heating LLC 1 Room name hall utility 2 Exposed wall 23.0 ft 14.0 It 3 Ceiling height 9.0 ft heallcool 9.0 ft heaticool 4 Room dimensions 1.0 x 229.5 ft 1.0 x 97.5 It 5 Room area 229.5 IF 97.5 IF Ty Construction U-value Or HTM Area (W) Load Area (ft2) Load number (Btuh/ft,.F) (BtuhHt� or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heal Cool Gross WP/S Heat Cool Gross WP/S Heat Cool 6 W 12F-Osw 0.065 n 4.94 0.47 0 0 0 0 0 0 0 0 I-O 61A 0.340 n 25.84 10.46 0 0 0 0 0 0 0 0 V� 12F-Osw 0.065 a 4.94 0.47 99 99 489 47 0 0 0 0 -6 61A 0.340 a 25.84 32.83 0 0 0 0 0 0 0 0 11 12F-0sw 0.065 s 4.94 0.47 108 87 430 41 126 126 622 60 61A 0.340 s 25.84 18.26 0 0 0 0 0 0 0 0 11Jo 0.600 s 45.60 11.10 21 21 958 233 0 0 0 0 12F-0sw 0.065 w 4.94 0.47 0 0 0 0 0 0 0 0 1Da T-::11J0 61A 0.340 w 25.94 32.83 0 0 0 0 0 0 0 0 0.600 w 45.60 11.10 0 0 0 0 0 0 0 0 W 12F-0sw 0.065 nw 4.94 0.47 0 0 0 0 0 0 0 0 r-O 61A 0.340 nw 25.84 22.98 0 0 0 0 0 0 0 0 C 168-38ad 0.026 - 1.98 1.09 146 146 288 159 28 28 54 30 F 20P-21c o.047 - 3.57 0.09 0 0 0 0 0 0 0 0 F 19C-Ocscp 0.368 1.85 0.34 230 23 424 78 98 14 180 33 6 c) AED excursion -31 -69 Envelope losstgain 2588 527 857 54 12 a) Infiltration 658 65 400 40 b) Room ventilation 1 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances @ 1200 0 0 1 1200 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution -3245 -592 1015 185 14 Subtotal 0 0 2272 1479 15 Duct loads 32% 58% 0 0 32% 58% 734 862 Total room load 0 0 3006 2341 Air required (cfm) 0 0 60 103 ACCA to meet all requirements of Manual J 8th Ed. w"cj"Csoft Right -Suite Residential6.0.02 RSR40615 2007-May-2416:23:43 AV-Cl', DAWrightsoft HVAC\Dave Sanderson(2695 with 400 bonus).np Calc=MJB Onentation=N Page Righ-, Worksheet Entire House ,v Job: 1 Date: May 24, 2007 By: J & B Heating LLC 1 Room name bonus kitchen/dining 2 Exposed wall 104.0 ft 24.6 It 3 Ceiling height 8.0 ft heaf/ccol 9.0 0 heat/cool 4 Room dimensions 14.0 x 38.0 ft 1.0 x 469.0 ft 5 Room area 532.0 ft2 469.0 ft2 Ty Construction U-value Or HTM Arm OF) Load Area (" Load number (Bluh/It2-'F) (Btuh/ft2) or perimeter (11) (Btuh) or perimeter (ft) (Btuh) Heal Cod Gross WP/S Heel Cool Gross WPM Heat I Cool 6 Vy 12F-0sw 0.065 n 4.94 0.47 112 112 553 53 126 96 474 46 Lf' 61A 0.340 n 25.84 10.46 0 0 0 0 30 0 775 314 W, 12Ffisw 0.065 a 4.94 0.47 304 304 1502 144 0 0 0 0 -C 61A 0.340 a 25.84 32.83 0 0 0 0 0 0 0 0 11 12F-0sw 0.065 s 4.94 0.47 112 112 553 53 0 0 0 0 61A 0.340 s 25.84 18.26 0 0 0 0 0 0 0 0 11J0 0.600 s 45-W 11.10 0 0 0 0 0 0 0 0 12F-0sw 0.065 w 4.94 0.47 304 304 1502 144 63 42 207 20 61A 0.340 w 25.84 32.83 0 0 0 0 0 0 0 0 tI--DG 11J0 0.600 w 45.60 11.10 0 0 0 0 21 21 958 233 VN 12F-0sw 0.065 nw 4.94 0.47 0 0 0 0 32 11 54 5 �--G 61A 0.340 my 25.84 22.98 0 0 0 0 22 0 556 494 C 168-38ad 0.026 - 1.98 1.09 532 532 1051 581 469 469 927 512 F 20P-210 0.047 - 3.67 0.09 378 74 1350 36 0 0 0 0 F 19C-0csco 0.368 - 1.85 0.34 0 0 0 0 469 25 866 159 6 c)AED excursion -64 -52 Envelope lossigain 6512 947 4817 1731 12 a) Infiltration 2644 261 704 69 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances @ 1200 0 0 2 2400 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 0 0 828 165 14 Subtotal 9156 1208 6348 4365 15 Dud loads 37% 68% 3351 819 32% 58% 2051 2544 Total room load 12507 2027 8399 6909 Air required (cfm) 251 90 169 305 Printout certified by ACCA to meet aU requirements of Manual J 8th Ed. wr-sghtsoR Right-Sude Residential 6.0.02 RSR40615 2007-May-2416:23:43 Aff�31 DAWrightsofl HVAC1Oave Sanderson (2695 with 400 bonus).m; Cale = MJ8 Orientation = N Page 6 Job: 1 Righ,- Worksheet Entire House Date: May 24, 2007 By: J & B Heating LLC 1 Room name privacyjohn mas clst. 2 Exposed wall 0.0 It 0.0 It 3 Ceiling height 9.0 It heallcool 9.0 ft heat/cool 4 Room dimensions 4.0 x 4.0 ft 7.0 x 8.0 ft 5 Roem area 16.0 ft' 56.0 W Ty Construction U-value Or HTM Area (fn Load Area (ft-) Load number (Btuh/ft?-'F) (Btuh/ft-) or perimeter (ft) (Blub) or perimeter (fl) (Btuh) Halt Cool Gross WP5 Heat Cod Gross WP/S Heat I Cool 6 y/ 12F41sw 0.065 n 4.94 0.47 0 0 0 0 0 0 0 0 I-C 61A 0.340 n 25.84 10.46 0 0 0 0 0 0 0 0 y/ 12F-0sw 0.065 a 4.94 0.47 0 0 0 0 0 0 0 0 t-C 61A 0.340 a 25.84 32.83 0 0 0 0 0 0 0 0 17 12F-0sw 0.065 s 4.94 0.47 0 0 0 0 0 0 0 0 61A 0.340 s 25.84 18.26 0 0 0 0 0 0 0 0 11,10 0.600 s 45.60 11.10 0 0 0 0 0 0 0 0 Vy 12F-0sw 0.065 w 4.94 0.47 0 0 0 0 0 0 0 0 {L-0D 61A 0.340 w 25.84 32.83 0 0 0 0 0 0 0 0 11JD 0.600 w 45.60 11.10 0 0 0 0 0 0 0 0 VN 12F-0sw 0.065 nw 4.94 0.47 0 0 0 0 0 0 0 0 1---G 61A 0.340 nw 25.84 22.98 0 0 0 0 0 0 0 0 C 166-38ad 0.026 - 1.98 1.09 16 16 32 17 56 56 111 61 F 20P-21c 0.047 - 3.57 0.09 0 0 0 0 0 0 0 0 F 19C-0cscp 0.368 1.85 0.34 16 0 30 5 56 0 103 19 6 c) AED excursion -1 -4 Envelope loss/gain 61 22 214 76 12 a) Infiltration 0 0 0 0 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants @ 230 0 0 0 0 Appliances @ 1200 0 0 0 0 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 177 37 -214 -76 14 Subtotal 238 59 0 0 151 Duct loads 32% 58% 77 34 32% 58% 0 0 Total room load 315 93 0 0 Air required (rim) 6 4 0 0 of Manual J 8th Ed. wrtghtsofC RightSufte Residential 6.0.02 RSR40615 D:%Whghtsoft HVAC\Dave Sanderson (2695 with 400 bonus).np Cab = MJB Orientation = N 2007-May-2416:23:43 Page 7 Job: 1 Righ,_.., Worksheet Entire House Date: May 24, 2007 By: J & B Heating LLC 1 Room name mas bath mas bed 2 Exposed wall 12.0 It 36.0 It 3 Ceding height 9.0 It heal/cool 9.0 ft heaVcool 4 Room dimensions 14o x 12.0 ft 21.0 x 15.0 ft 5 Room area 168.0 ft" 315.0 fl Ty Construction U-value Or HTM Area (W) Load Area (ft.) Load number (BtuhM'-°F) (Btuh/ft-) or perimeter (ft) (Btuh) or perimeter (ft) (Btuh) Heat Cool Gross WP/S Heal Cool Gross WPM Heat Cool 6 Vy 12F-0sw 0.065 n 4.94 0.47 0 0 0 0 189 129 637 61 . L- G 61A 0.340 n 25.84 10.46 0 0 0 0 60 0 1550 627 12F-0sw 0.065 a 4.94 0.47 108 92 454 44 135 105 519 50 t--G 61A 0.340 a 25.84 32.93 16 0 413 525 30 0 775 985 11 Vy 12F-0sw 0.065 s 4.94 0.47 0 0 0 0 0 0 0 0 I-G 61A 0,340 s 25.84 18.26 0 0 0 0 0 0 0 0 I-O 1/J0 0.600 s 45.60 11.10 0 0 0 0 0 0 0 0 0.065 w 4.94 0.47 0 0 0 0 0 0 0 0 tt12F-0sw 61A 0.340 w 25.84 32.83 0 0 0 0 0 0 0 0 11J0 0.600 w 45.60 11.10 0 0 0 0 0 0 0 0 12F-0sw 0.065 nw 4.94 0.47 0 0 0 0 0 0 0 0 61A 0.340 nw 25.84 22.98 0 0 0 0 0 0 0 0 C 16B-38ad 0.026 - 1.98 1.09 168 168 332 183 315 315 622 344 F 20P-21c 0.047 - 3.57 0.09 0 0 0 0 0 0 0 0 F 19C-0t=0 0.368 - 1.85 0.34 168 12 310 57 315 36 581 107 6 c) AED excursion 29 -126 Envelope losa/gain 1510 839 4685 2048 12 a) Infiltration 343 34 1030 102 b) Room ventilation 0 0 0 0 13 Internal gains: Occupants a 230 0 0 1 230 Appliances Q 1200 0 0 0 0 Less external load 0 0 0 0 Less transfer 0 0 0 0 Redistribution 575 115 50 18 14 Subtotal 2429 988 5765 2398 15 Dud loads 32% 58%1 785 576 32% 58% 1. 1387 Total room load 1 1 3213 1563 7628 3795 Air required (dm) 64 69 153 168 all requirements of Manual J 8th Ed. wreghtsolFt RightSuite Residentia16.0.02 RSR40615 14C3CO' DAWrightsoft HVAC\Dave Sanderson (2695 YAM 400 bonus).np Cale = MJ8 Orientation = N 2007-May-24 16:23:43 Page 8 Righx Worksheet Entire House �r Job: 1 Date: May 24, 2007 By: J & B Heating LLC 1 Room name hall 2 Exposed wall 0.0 It 3 Ceiling height 9.0 8 heaVood 4 Room dimensions 4.0 x 12.0 0 5 Room area 48.0 ft Ty Construction D-value Or HTM Area (W) Load Area Load number (BtuhW--'F) (Btuh)ft2) or perimeter (8) (Bluh) or perimeter Heal I Cod Gross WPIS Heat Cod Gross WP)S Heat Cool 6 W 12F-Osw 0.065 n 4.94 OA7 0 0 0 0 �C 61A 12F-0sw 0.340 0.065 n a 25.84 4.94 10.46 0.47 0 0 0 0 0 0 0 0 Vd/ --C 61A 0.340 a 25.84 32.93 0 0 0 0 11 12F-Osw 0.066 s 4.94 0.47 0 0 0 0 61A 0.340 s 25.84 18.26 0 0 0 0 11J0 0.600 s 45.60 11.10 0 0 0 0 V1/ 12F-Osw 0.065 w 4.94 0.47 0 0 0 0 61A 0.340 w 25.84 32.53 0 0 0 0 �1D- 11J0 0.600 w 45.60 11.10 0 0 0 0 Uri 12F-Osw 0.065 nw 4.94 0.47 0 0 0 0 T-0 61A 0.340 nw 25.84 22.98 0 0 0 0 C 168-38ad 0.026 - 1.98 1.09 48 48 95 52 F 20P-21c 0.g47 - 3.57 0.09 0 0 0 0 F 19C-Ocsco 0.368 - 1.85 0.34 48 0 89 16 6 c) AED emursion -3 Envelope loss/gain 183 65 12 a) Infiltration 0 0 b) Room ventilation 0 0 13 Internal gains: Occupants a 230 0 0 Appliances Q 1200 0 0 Less external load 0 0 Less transfer 0 0 Redistribution -183 -65 14 Subtotal 0 0 15 Duct loads 32% 58% 0 0 Total room load 0 0 Air required (rim) 0 0 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. w�ght50fC RigWSuite Residential 6.0.02 RSR40615 2007-May-2416:23.43 16-A D:\Wrightsoft HVAC\Dave Sanderson (2695 with 400 bonus).mp Cab = Wit Odentalion = N Page 9 Level 2 Job M 1 Performed by J & B Heating LLC for: Sanderson Residence Rexburg, Idaho 83440 Scale: 1 : 134 Page 1 Right -Suite Residential 6.0.02 RSR40615 2007-May-24 16:24:07 itsoft HVAC1Dave Sanc Main floor Job #: 1 Performed by J & B Heating LLC for: Sanderson Residence Rexburg, Idaho 83440 Scale: 1 : 134 Page 2 Right -Suite Residential 6.0.02 RSR40615 2007-May-24 16:24:07 itsoR HVAC.Dave Sanderson.. Duct system Summary Entire House For. Sanderson Residence Rexburg, Idaho 83440 External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.80 in H2O 0.47 in H2O 0.33 in H2O 0.16 / 0.17 in H2O 0.076 in/100ft 1266 cfm 435 ft Job: 1 Date: May 24, 2007 By: J & B Heating LLC Cooling 0.80 in H2O 0.47 in H2O 0.33 in H2O 0.16 / 0.17 in H2O 0.076 in/100ft 1266 cfm Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Diam (in) Rect Size (in) Duct Matt Actual Ln (ft) Ftg.Egv Ln (ft) Trunk bed 1 h 4310 87 59 0.081 6 OxO VIFx 50.0 150.0 st2A bath c 770 31 34 0.078 6 Ox 0 VIFx 47.0 160.0 st2C bed 2 h 5048 101 98 0.076 6 Ox 0 VIFx 59.0 155.0 st2B bed 3 c 1980 67 87 0.080 6 OxO VIFx 44.0 160.0 WA entry h 2735 55 49 0.089 6 OxO VIFx 27.0 155.0 st2 great room h 3254 65 60 0.078 6 OxO VIFx 37.0 170.0 st2A great hconi h 3254 65 60 0.095 6 Ox0 VIFx 26.0 145.0 st2 once h 4530 91 80 0.083 6 OxO VIFx 20.0 175.0 st2 Utility c 2341 60 103 0.089 6 OxO VIFx 33.0 150.0 st3A bonus -A h 6253 126 45 0.077 6 Ox 0 VIFx 55.7 155.0 st4 bonus h 6253 126 45 0.089 6 OxO VIFx 28.1 155.0 st4 kitchen/dining-A c 3455 84 153 0.096 6 OxO VIFx 24.0 145.0 kitchen/dining c 3455 84 153 0.093 6 OxO \/IFx 10.0 165.0 st2 privacyjohn h 315 6 4 0.093 6 OxO VIFx 15.0 160.0 st3A mas bath c 1563 64 69 0.083 6 OxO VIFx 36.0 160.0 st3B mas bed c 1897 77 84 0.089 6 Ox 0 VIFx 37.0 145.0 st3 mas bed -A c 1897 77 84 0.079 6 Ox 0 VIFx 50.0 155.0 st3A Soid'"x vakms have been mama lly overridden wnghtsoft RightSude Residerdia16.0.02RSR40615 2007-May-2416:23'54 MCA D'.1Wnghtsoft HVAC1Dave Sanderson (2695 "h 400 bonus).ap Cab = MJ8 Orientation = N Page 1 Name Trunk Type Htg (cfm) Clg (cfm) Design FIR Veloc (fpm) Diam (in) Rect Duct Size (in) Duct Material Trunk st3 Peak AVF 284 344 0.079 774 9 8 x 8 ShtMetl st1 st1 Peak AVF 535 434 0.077 803 11 8 x 12 ShtMetl st4 Peak AVF 251 90 0.077 565 8 8 x 8 . ShtMetl st1 st3B Peak AVF 64 69 0.083 621 6 8 x 2 ShtMetl rt3A st3A Peak AVF 208 260 0.079 586 8 8 x 8 ShtMetl st3 st2 Peak AVF 646 680 0.076 765 13 8 x 16 ShtMetl st2A Peak AVF 351 339 0.076 790 9 8 x 8 ShtMetl st2 st2B Peak AVF 133 132 0.076 1194 6 8 x 2, ShtMed st2A st2C Peak AVF 31 34 0.078 306 6 8 x 2 ShtMetl st2B Grill Size (in) Htg (cfm) Clg (cfm) TEL (ft) Design FIR Veloc (fpm) Diam (in) RectSize (m) Sfud/Joist Opening (in) Duct Mad Trunk frb4 Ox 0 251 90 221.0 0.076 397 8 2-14x3.25 2-10x9 SJSp rt4 0x0 125 172 186.0 0.090 546 6 14x3.25 1Ox5 SJSp rt3A Ox 0 146 129 91.0 0.184 462 7 14x3.25 1 Ox5 SJSp rt2 Ox0 83 88 106.0 0.158 278 6 14x3.25 tOx5 SJSp rt2 0x0 200 339 135.0 0.124 537 10 2-14x3.25 2-1Ox9 SJSp rt2 rb5 rb6 ox0 Ox0 244 217 270 179 169.0 0.099 427 9 2-14x3.25 2-1Ox9 SJSp rt2A 156.0 0.107 687 7 IW.25 10x5 SJSp I rt2A Name Design FIR Veloc Diam Rect Duct Duct (fpm) (in) Size (in) Material Trunk rt1 jPeak T462448 0.076 677 9 8 x 10 ShtMetl rt3A 0.090 388 6 8 x 8 ShtMeb rt1 rt4 0 0.076 565 8 8 x 8 ShtMetl rt1 rt2 rt2A 0.099 753 18 8 x 24 ShtMetl 0.099 1 831 12 8 x 10 ShtMetl rt2 wnghtsoft RightSu#e ReaidenWI6.0.o2RSR40615 2007-May-2416:23:54 ACCA DAWnghtsoft HVACIDave Sanderson (2695 with 400 bonus).np Cak = Md8 Orientation = N Page 2