HomeMy WebLinkAboutTRUSS SPECS - 21-00261 - 824 S 2315 W - New SFRJob
HUNTINGTON FH
Truss
A1
Truss Type
GABLE
Qty
1
Ply
1
KARTCHNER HUNTINGTON FH
Job Reference (optional)
8.420 s Dec 1 2020 MiTek Industries, Inc. Wed Feb 3 16:07:53 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:Mal0Hw1zlTRcVyigOH32jizouXb-fOyLKs3M3gsbK530uqYC4OoiXb19KBcMklwsERzonYq
Scale: 3/16"=1'
T2 T2
B1
W1 W2
W3
W4
W2W3
W4
T1 T1
B1B2
ST11
ST12
ST9
ST10
ST8
ST6
ST7
ST5
ST3
ST4ST2
ST1
ST11
ST12
ST9
ST10
ST8
ST6
ST7
ST5
ST3
ST4 ST2
ST1
A B
C
D
E
F
G
H I
N M L K J
BA
BB BC
BD
BE BF BG BH BI BJ
5x8
5x6
5x8
5x6
3x8 3x4 3x4
5x6
5x6 5x6
9-6-0
9-6-0
19-0-0
9-6-0
28-6-0
9-6-0
38-0-0
9-6-0
-1-0-0
1-0-0
6-4-0
6-4-0
12-8-0
6-4-0
19-0-0
6-4-0
25-4-0
6-4-0
31-8-0
6-4-0
38-0-0
6-4-0
39-0-0
1-0-0
0-
4
-
3
9-
1
0
-
3
10
-
3
-
1
5
0-
4
-
3
6.00 12
Plate Offsets (X,Y)-- [B:0-1-11,Edge], [D:0-4-0,0-3-0], [F:0-4-0,0-3-0], [H:0-1-11,Edge], [K:0-3-0,0-3-4], [M:0-3-0,0-3-4]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.52
0.61
0.48
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.32
-0.47
0.15
0.31
(loc)
L-N
L-N
H
L-N
l/defl
>999
>953
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 278 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std *Except*
W1,W2: 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F
1.6E
OTHERS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 3-0-8 oc purlins.
BOT CHORD Rigid ceiling directly applied or 4-5-2 oc bracing.
WEBS 1 Row at midpt E-L, F-L, D-L
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)B=1948/0-5-8 (min. 0-2-1), H=1948/0-5-8 (min. 0-2-1)
Max Horz B=211(LC 11)
Max UpliftB=-755(LC 12), H=-755(LC 12)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-BA=-3472/2278, C-BA=-3369/2292, C-D=-3094/2226, D-BB=-2176/1610, E-BB=-2046/1625,
E-BC=-2046/1625, F-BC=-2176/1610, F-G=-3094/2226, G-BD=-3369/2292, H-BD=-3472/2278
BOT CHORD B-BE=-1897/2982, N-BE=-1897/2982, N-BF=-1482/2440, M-BF=-1482/2440, M-BG=-1482/2440,
L-BG=-1482/2440, L-BH=-1488/2440, K-BH=-1488/2440, K-BI=-1488/2440, J-BI=-1488/2440,
J-BJ=-1897/2982, H-BJ=-1897/2982
WEBS E-L=-1138/1338, F-L=-881/668, F-J=-532/516, G-J=-456/278, D-L=-881/668, D-N=-532/516,
C-N=-456/278
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=38ft; eave=2ft; Cat. II; Exp C; Enclosed;
MWFRS (directional) and C-C Corner(3) -1-0-13 to 2-8-13, Exterior(2) 2-8-13 to 19-0-0, Corner(3) 19-0-0 to 22-9-10, Exterior(2) 22-9-10
to 39-0-13 zone; cantilever left and right exposed ; end vertical left and right exposed; porch left and right exposed;C-C for members and
forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) All plates are 1.5x4 MT20 unless otherwise indicated.
5) Gable studs spaced at 2-0-0 oc.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) B=755,
H=755.
9) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
HUNTINGTON FH
Truss
A2
Truss Type
Common
Qty
7
Ply
1
KARTCHNER HUNTINGTON FH
Job Reference (optional)
8.420 s Dec 1 2020 MiTek Industries, Inc. Wed Feb 3 16:07:56 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:Mal0Hw1zlTRcVyigOH32jizouXb-4zdUyu5ELbEABYobay5vi0QEzo3sXZUoQj9WrmzonYn
Scale: 3/16"=1'
T2 T2
B1
W1 W2
W3
W4
W2
W3
W4
T1 T1
B1B2AB
C
D
E
F
G
H I
N M L K J
O
P Q
R
S T U V
5x8
5x6
5x8
5x6
5x6 3x8 3x4
1.5x4
3x4
1.5x4
5x6
5x6
9-6-0
9-6-0
19-0-0
9-6-0
28-6-0
9-6-0
38-0-0
9-6-0
-1-0-0
1-0-0
6-4-0
6-4-0
12-8-0
6-4-0
19-0-0
6-4-0
25-4-0
6-4-0
31-8-0
6-4-0
38-0-0
6-4-0
39-0-0
1-0-0
0-
4
-
3
9-
1
0
-
3
10
-
3
-
1
5
0-
4
-
3
6.00 12
Plate Offsets (X,Y)-- [B:0-1-11,Edge], [D:0-4-0,0-3-0], [F:0-4-0,0-3-0], [H:0-1-11,Edge]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.51
0.61
0.41
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.32
-0.47
0.15
0.27
(loc)
L-N
L-N
H
L-N
l/defl
>999
>953
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 179 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std *Except*
W1,W2: 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F
1.6E
BRACING-
TOP CHORD Sheathed or 3-0-8 oc purlins.
BOT CHORD Rigid ceiling directly applied or 5-0-10 oc bracing.
WEBS 1 Row at midpt E-L, F-L, D-L
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)B=1948/0-5-8 (min. 0-2-1), H=1948/0-5-8 (min. 0-2-1)
Max Horz B=211(LC 11)
Max UpliftB=-755(LC 12), H=-755(LC 12)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-O=-3472/1794, C-O=-3369/1809, C-D=-3094/1774, D-P=-2176/1269, E-P=-2046/1284,
E-Q=-2046/1284, F-Q=-2176/1269, F-G=-3094/1774, G-R=-3369/1809, H-R=-3472/1794
BOT CHORD B-N=-1517/2982, N-S=-1187/2440, M-S=-1187/2440, M-T=-1187/2440, L-T=-1187/2440,
L-U=-1202/2440, K-U=-1202/2440, K-V=-1202/2440, J-V=-1202/2440, H-J=-1524/2982
WEBS E-L=-953/1338, F-L=-881/504, F-J=-453/516, G-J=-456/183, D-L=-881/504, D-N=-453/516,
C-N=-456/183
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=38ft; eave=5ft; Cat. II; Exp C; Enclosed;
MWFRS (directional) and C-C Exterior(2) -1-0-13 to 2-8-13, Interior(1) 2-8-13 to 19-0-0, Exterior(2) 19-0-0 to 22-9-10, Interior(1) 22-9-10
to 39-0-13 zone; cantilever left and right exposed ; end vertical left and right exposed; porch left and right exposed;C-C for members and
forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) B=755,
H=755.
6) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
HUNTINGTON FH
Truss
A3
Truss Type
Common
Qty
11
Ply
1
KARTCHNER HUNTINGTON FH
Job Reference (optional)
8.420 s Dec 1 2020 MiTek Industries, Inc. Wed Feb 3 16:07:58 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:Mal0Hw1zlTRcVyigOH32jizouXb-0MlENZ7VtCUtRsy_hN7NnRVZ2ckJ?Tn5t1edwezonYl
Scale = 1:63.2
T2 T2
B1
W4
W3
W2 W1 W2
W3
W4
T1 T3
B3B2A
B
C
D
E
F
G
H
M L K J I
N
O P
Q
R S T U
5x8
5x6
5x8
5x6
5x6 3x4
1.5x4
3x8 3x4
1.5x4
5x6
5x6
9-6-0
9-6-0
19-0-0
9-6-0
28-6-0
9-6-0
37-9-0
9-3-0
-1-0-0
1-0-0
6-4-0
6-4-0
12-8-0
6-4-0
19-0-0
6-4-0
25-4-0
6-4-0
31-8-0
6-4-0
37-9-0
6-1-0
0-
4
-
3
9-
1
0
-
3
10
-
3
-
1
5
0-
5
-
1
1
6.00 12
Plate Offsets (X,Y)-- [B:0-1-11,Edge], [D:0-4-0,0-3-0], [F:0-4-0,0-3-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.54
0.61
0.42
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.32
-0.47
0.14
0.28
(loc)
K-M
K-M
H
H-I
l/defl
>999
>953
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 176 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std *Except*
W2,W1: 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F
1.6E
BRACING-
TOP CHORD Sheathed or 3-0-2 oc purlins.
BOT CHORD Rigid ceiling directly applied or 4-11-12 oc bracing.
WEBS 1 Row at midpt D-K, E-K, F-K
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)B=1946/0-5-8 (min. 0-2-1), H=1834/Mechanical
Max Horz B=208(LC 11)
Max UpliftB=-755(LC 12), H=-701(LC 12)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-N=-3468/1794, C-N=-3364/1809, C-D=-3089/1774, D-O=-2171/1268, E-O=-2041/1282,
E-P=-2041/1288, F-P=-2171/1274, F-G=-3081/1790, G-Q=-3304/1828, H-Q=-3430/1813
BOT CHORD B-M=-1542/2978, M-R=-1219/2435, L-R=-1219/2435, L-S=-1219/2435, K-S=-1219/2435,
K-T=-1211/2431, J-T=-1211/2431, J-U=-1211/2431, I-U=-1211/2431, H-I=-1548/2960
WEBS C-M=-456/183, D-M=-454/516, D-K=-881/505, E-K=-957/1334, F-K=-877/500, F-I=-466/513,
G-I=-446/192
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=38ft; eave=5ft; Cat. II; Exp C; Enclosed;
MWFRS (directional) and C-C Exterior(2) -1-0-13 to 2-8-8, Interior(1) 2-8-8 to 19-0-0, Exterior(2) 19-0-0 to 22-9-5, Interior(1) 22-9-5 to
37-8-4 zone; cantilever left and right exposed ; end vertical left and right exposed; porch left and right exposed;C-C for members and
forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
5) Refer to girder(s) for truss to truss connections.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) B=755,
H=701.
7) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
HUNTINGTON FH
Truss
A4
Truss Type
GABLE
Qty
1
Ply
1
KARTCHNER HUNTINGTON FH
Job Reference (optional)
8.420 s Dec 1 2020 MiTek Industries, Inc. Wed Feb 3 16:08:00 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:Mal0Hw1zlTRcVyigOH32jizouXb-ykt?oF8lPqkbgA6MpoArssbumPQmTM6OLL7j_XzonYj
Scale = 1:63.2
T2 T2
B1
W4
W3 W2 W1 W2
W3
W4
T1 T3
B3B2
ST11
ST12
ST9
ST10
ST8
ST6
ST7
ST5
ST3
ST4ST2ST1
ST11
ST12
ST9
ST10
ST8
ST6
ST7
ST5
ST3
ST4 ST2 ST1
A
B
C
D
E
F
G
H
M L K J I
AZ
BA BB
BC
BD BE BF BG BH BI
5x8
5x6
5x8
5x6
3x4 3x8 3x4
5x6
5x6 5x6
9-6-0
9-6-0
19-0-0
9-6-0
28-6-0
9-6-0
37-9-0
9-3-0
-1-0-0
1-0-0
6-4-0
6-4-0
12-8-0
6-4-0
19-0-0
6-4-0
25-4-0
6-4-0
31-8-0
6-4-0
37-9-0
6-1-0
0-
4
-
3
9-
1
0
-
3
10
-
3
-
1
5
0-
5
-
1
1
6.00 12
Plate Offsets (X,Y)-- [B:0-1-11,Edge], [D:0-4-0,0-3-0], [F:0-4-0,0-3-0], [J:0-3-0,0-3-4], [L:0-3-0,0-3-4]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.59
0.61
0.50
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.32
-0.47
0.14
0.31
(loc)
K-M
K-M
H
K-M
l/defl
>999
>953
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 276 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std *Except*
W2,W1: 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F
1.6E
OTHERS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 3-0-2 oc purlins.
BOT CHORD Rigid ceiling directly applied or 4-4-11 oc bracing.
WEBS 1 Row at midpt D-K, E-K, F-K
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)B=1946/0-5-8 (min. 0-2-1), H=1834/Mechanical
Max Horz B=208(LC 11)
Max UpliftB=-755(LC 12), H=-701(LC 12)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD B-AZ=-3468/2276, C-AZ=-3364/2291, C-D=-3089/2224, D-BA=-2171/1608, E-BA=-2041/1622,
E-BB=-2041/1629, F-BB=-2171/1615, F-G=-3081/2244, G-BC=-3304/2315, H-BC=-3430/2301
BOT CHORD B-BD=-1919/2978, M-BD=-1919/2978, M-BE=-1509/2435, L-BE=-1509/2435, L-BF=-1509/2435,
K-BF=-1509/2435, K-BG=-1501/2431, J-BG=-1501/2431, J-BH=-1501/2431, I-BH=-1501/2431,
I-BI=-1940/2960, H-BI=-1940/2960
WEBS C-M=-456/278, D-M=-533/516, D-K=-881/668, E-K=-1142/1334, F-K=-877/663, F-I=-548/513,
G-I=-446/295
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=38ft; eave=2ft; Cat. II; Exp C; Enclosed;
MWFRS (directional) and C-C Corner(3) -1-0-13 to 2-8-8, Exterior(2) 2-8-8 to 19-0-0, Corner(3) 19-0-0 to 22-9-5, Exterior(2) 22-9-5 to
37-8-4 zone; cantilever left and right exposed ; end vertical left and right exposed; porch left and right exposed;C-C for members and
forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) All plates are 1.5x4 MT20 unless otherwise indicated.
5) Gable studs spaced at 2-0-0 oc.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members, with BCDL = 7.0psf.
8) Refer to girder(s) for truss to truss connections.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) B=755,
H=701.
10) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
HUNTINGTON FH
Truss
B1
Truss Type
GABLE
Qty
1
Ply
1
KARTCHNER HUNTINGTON FH
Job Reference (optional)
8.420 s Dec 1 2020 MiTek Industries, Inc. Wed Feb 3 16:08:02 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:Mal0Hw1zlTRcVyigOH32jizouXb-v7_lDxA?xR_JwTGlwDCJxHgMIDF9xMVhofcq3QzonYh
Scale: 1/4"=1'
T1 T1
B1
ST5
ST4
ST3
ST2
ST1
ST4
ST3
ST2
HW1 HW1B1
ST1
A
B
C
D
E
F
G
H
I
J
K
L
M
V U T S R Q P O N
4x5
3x4
3x8 5x6
3x4
3x8
21-10-0
21-10-0
-1-0-0
1-0-0
10-11-0
10-11-0
21-10-0
10-11-0
22-10-0
1-0-0
0-
6
-
3
7-
9
-
8
8-
3
-
9
0-
6
-
3
8.00 12
Plate Offsets (X,Y)-- [B:0-0-0,0-0-12], [B:0-1-15,Edge], [L:0-1-15,Edge], [L:0-0-0,0-0-12], [R:0-3-0,0-3-0]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.07
0.04
0.12
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
in
-0.00
0.00
0.00
(loc)
L
L
L
l/defl
n/r
n/r
n/a
L/d
120
120
n/a
PLATES
MT20
Weight: 122 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
OTHERS 2x4 DF Stud/Std *Except*
ST5: 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEDGE
Left: 2x4 DF Stud/Std , Right: 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 6-0-0 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.All bearings 21-10-0.
(lb) - Max Horz B=-178(LC 10)
Max Uplift All uplift 100 lb or less at joint(s) B, S, T, U, V, Q, P, O, L, N
Max Grav All reactions 250 lb or less at joint(s) B, R, S, T, U, Q, P, O, L except V=262(LC 21), N=262(LC 22)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=25ft; eave=2ft; Cat. II; Exp C; Enclosed;
MWFRS (directional) and C-C Corner(3) -1-1-0 to 1-11-0, Exterior(2) 1-11-0 to 10-11-0, Corner(3) 10-11-0 to 13-11-0, Exterior(2) 13-11-0
to 22-11-0 zone; cantilever left and right exposed ; end vertical left and right exposed; porch left and right exposed;C-C for members and
forces & MWFRS for reactions shown; Lumber DOL=1.33 plate grip DOL=1.33
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see Standard Industry
Gable End Details as applicable, or consult qualified building designer as per ANSI/TPI 1.
4) All plates are 1.5x4 MT20 unless otherwise indicated.
5) Gable requires continuous bottom chord bearing.
6) Gable studs spaced at 2-0-0 oc.
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) B, S, T, U, V, Q, P, O,
L, N.
10) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
HUNTINGTON FH
Truss
B2
Truss Type
Common Girder
Qty
1
Ply
2
KARTCHNER HUNTINGTON FH
Job Reference (optional)
8.420 s Dec 1 2020 MiTek Industries, Inc. Wed Feb 3 16:08:05 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:Mal0Hw1zlTRcVyigOH32jizouXb-JiguryCuEMMunx_KbLl0ZwIhWQ3v8Y27UdrUgkzonYe
Scale = 1:50.2
T1 T1
B1
W1
W2 W3
W4
W2W3
W4
B1
A
B
C
D
E
F
G
J I HKLMNOPQ R S T
5x12 MT20HS
9x12 MT18HS
5x12 MT20HS12x12
6x8
12x12
1.5x4
6x8
12x12
1.5x4
Special
Special
Special Special
Special
Special
Special Special
Special
Special
Special
5-5-8
5-5-8
10-11-0
5-5-8
16-4-8
5-5-8
21-10-0
5-5-8
3-7-11
3-7-11
7-3-5
3-7-11
10-11-0
3-7-11
14-6-11
3-7-11
18-2-5
3-7-11
21-10-0
3-7-11
0-
6
-
3
7-
9
-
8
0-
6
-
3
8.00 12
Plate Offsets (X,Y)-- [A:0-1-12,0-2-5], [G:0-1-12,0-2-5], [H:0-6-0,0-7-8], [I:0-6-0,0-7-8], [J:0-6-0,0-7-8]
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
NO
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-SH
0.78
0.87
0.77
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.23
-0.32
0.06
0.18
(loc)
H-I
H-I
G
H-I
l/defl
>999
>792
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
MT20HS
MT18HS
Weight: 315 lb FT = 20%
GRIP
220/195
165/146
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x10 DF 1950F 1.7E or 2x10 DF SS
WEBS 2x4 DF Stud/Std *Except*
W1,W3: 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F
1.6E
BRACING-
TOP CHORD Sheathed or 2-10-11 oc purlins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS.(lb/size)A=11171/0-5-8 (req. 0-5-15), G=10942/0-5-8 (req. 0-5-13)
Max Horz A=160(LC 7)
Max UpliftA=-4225(LC 8), G=-4137(LC 8)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
TOP CHORD A-B=-14643/5512, B-C=-14488/5532, C-D=-10288/3963, D-E=-10287/3963, E-F=-14943/5703,
F-G=-15097/5684
BOT CHORD A-K=-4480/11959, K-L=-4480/11959, L-M=-4480/11959, J-M=-4480/11959, J-N=-3824/10320,
N-O=-3824/10320, I-O=-3824/10320, I-P=-3895/10508, P-Q=-3895/10508, H-Q=-3895/10508,
H-R=-4622/12338, R-S=-4622/12338, S-T=-4622/12338, G-T=-4622/12338
WEBS D-I=-4287/10975, E-I=-3345/1313, E-H=-2063/5310, F-H=-273/249, C-I=-3034/1196,
C-J=-1861/4773, B-J=-274/250
NOTES-
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2x4 - 1 row at 0-4-0 oc.
Bottom chords connected as follows: 2x10 - 2 rows staggered at 0-2-0 oc.
Webs connected as follows: 2x4 - 1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply
connections have been provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Unbalanced roof live loads have been considered for this design.
4) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=25ft; eave=4ft; Cat. II; Exp C; Enclosed;
MWFRS (directional); cantilever left and right exposed ; end vertical left and right exposed; porch left and right exposed; Lumber
DOL=1.33 plate grip DOL=1.33
5) All plates are MT20 plates unless otherwise indicated.
6) The Fabrication Tolerance at joint I = 16%
7) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
8) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
9) WARNING: Required bearing size at joint(s) A, G greater than input bearing size.
10) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) except (jt=lb) A=4225
, G=4137.
11) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
Continued on page 2
Job
HUNTINGTON FH
Truss
B2
Truss Type
Common Girder
Qty
1
Ply
2
KARTCHNER HUNTINGTON FH
Job Reference (optional)
8.420 s Dec 1 2020 MiTek Industries, Inc. Wed Feb 3 16:08:06 2021 Page 2 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:Mal0Hw1zlTRcVyigOH32jizouXb-nuEG2IDW?fVlO5ZW92HF67rsGqP8t?IGjHa2CBzonYd
NOTES-
12) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 1822 lb down and 694 lb up at 0-10-12, 1820 lb down and 693 lb up at
2-10-12, 1820 lb down and 693 lb up at 4-10-12, 1820 lb down and 693 lb up at 6-10-12, 1820 lb down and 693 lb up at 8-10-12, 1820 lb down and 693 lb up at 10-10-12,
1820 lb down and 693 lb up at 12-10-12, 1820 lb down and 693 lb up at 14-10-12, 1820 lb down and 693 lb up at 16-10-12, and 1820 lb down and 693 lb up at 18-10-12,
and 1820 lb down and 693 lb up at 19-9-4 on bottom chord. The design/selection of such connection device(s) is the responsibility of others.
LOAD CASE(S) Standard
1) Dead + Roof Live (balanced): Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: A-D=-84, D-G=-84, A-G=-14
Concentrated Loads (lb)
Vert: I=-1820(B) K=-1822(B) L=-1820(B) M=-1820(B) N=-1820(B) O=-1820(B) P=-1820(B) Q=-1820(B) R=-1820(B) S=-1820(B) T=-1820(B)
Job
HUNTINGTON FH
Truss
J1
Truss Type
Monopitch
Qty
8
Ply
1
KARTCHNER HUNTINGTON FH
Job Reference (optional)
8.420 s Dec 1 2020 MiTek Industries, Inc. Wed Feb 3 16:08:07 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:Mal0Hw1zlTRcVyigOH32jizouXb-F5oeGeE8mzdc0E8ijmoUeLN8uEw_cedQyxKbkdzonYc
Scale = 1:13.5
T1
W1
B1
A
B
C
D
E
1.5x4
2x4
1.5x4
4-10-8
4-10-8
-1-0-0
1-0-0
4-10-8
4-10-8
5-0-0
0-1-8
0-
4
-
0
2-
2
-
8
2-
6
-
1
2
1-
1
1
-
0
0-
3
-
8
2-
2
-
8
4.50 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-P
0.34
0.19
0.00
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.03
-0.04
0.00
0.05
(loc)
B-D
B-D
D
B-D
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 18 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 4-10-8 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)B=344/0-3-8 (min. 0-1-8), D=218/0-1-8 (min. 0-1-8)
Max Horz B=78(LC 11)
Max UpliftB=-140(LC 12), D=-84(LC 12)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=25ft; eave=4ft; Cat. II; Exp C; Enclosed;
MWFRS (directional) and C-C Exterior(2) -1-0-10 to 1-11-6, Interior(1) 1-11-6 to 4-10-4 zone; cantilever left and right exposed ; end
vertical left and right exposed; porch left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber
DOL=1.33 plate grip DOL=1.33
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
4) Bearing at joint(s) D considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of
bearing surface.
5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) D.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) D except (jt=lb)
B=140.
7) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
HUNTINGTON FH
Truss
J2
Truss Type
Monopitch
Qty
12
Ply
1
KARTCHNER HUNTINGTON FH
Job Reference (optional)
8.420 s Dec 1 2020 MiTek Industries, Inc. Wed Feb 3 16:08:08 2021 Page 1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 ID:Mal0Hw1zlTRcVyigOH32jizouXb-jHM0T_EmWHlTeOjvHTJjBYwNceIGL5tZBb39G3zonYb
Scale = 1:9.9
T1
W1
B1
A
B
C
D
E
1.5x4
2x4
1.5x4
2-10-8
2-10-8
-1-0-0
1-0-0
2-10-8
2-10-8
3-0-0
0-1-8
0-
4
-
0
1-
5
-
8
1-
9
-
1
2
1-
2
-
0
0-
3
-
8
1-
5
-
8
4.50 12
LOADING (psf)
TCLL
TCDL
BCLL
BCDL
35.0
7.0
0.0 *
7.0
SPACING-
Plate Grip DOL
Lumber DOL
Rep Stress Incr
Code
2-0-0
1.15
1.15
YES
IRC2015/TPI2014
CSI.
TC
BC
WB
Matrix-P
0.08
0.06
0.00
DEFL.
Vert(LL)
Vert(CT)
Horz(CT)
Wind(LL)
in
-0.00
-0.00
0.00
0.01
(loc)
B-D
B-D
D
B-D
l/defl
>999
>999
n/a
>999
L/d
360
240
n/a
240
PLATES
MT20
Weight: 11 lb FT = 20%
GRIP
220/195
LUMBER-
TOP CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
BOT CHORD 2x4 DF 1800F 1.6E or 2x4 DF No.1&Btr or 2x4 DF-N 1800F 1.6E
WEBS 2x4 DF Stud/Std
BRACING-
TOP CHORD Sheathed or 2-10-8 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
MiTek recommends that Stabilizers and required cross bracing
be installed during truss erection, in accordance with Stabilizer
Installation guide.
REACTIONS.(lb/size)B=255/0-3-8 (min. 0-1-8), D=110/0-1-8 (min. 0-1-8)
Max Horz B=49(LC 9)
Max UpliftB=-109(LC 12), D=-44(LC 9)
FORCES.(lb) - Max. Comp./Max. Ten. - All forces 250 (lb) or less except when shown.
NOTES-
1) Wind: ASCE 7-10; Vult=115mph Vasd=91mph; TCDL=4.2psf; BCDL=4.2psf; h=25ft; B=45ft; L=25ft; eave=4ft; Cat. II; Exp C; Enclosed;
MWFRS (directional) and C-C Exterior(2) -1-0-10 to 1-11-6, Interior(1) 1-11-6 to 2-10-4 zone; cantilever left and right exposed ; end
vertical left and right exposed; porch left and right exposed;C-C for members and forces & MWFRS for reactions shown; Lumber
DOL=1.33 plate grip DOL=1.33
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) * This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit
between the bottom chord and any other members.
4) Bearing at joint(s) D considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of
bearing surface.
5) Provide mechanical connection (by others) of truss to bearing plate at joint(s) D.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 100 lb uplift at joint(s) D except (jt=lb)
B=109.
7) This truss is designed in accordance with the 2015 International Residential Code sections R502.11.1 and R802.10.2 and referenced
standard ANSI/TPI 1.
LOAD CASE(S) Standard