Loading...
HomeMy WebLinkAboutCHECKLIST - 07-00281 - 758 Yost St - New SFRD RESIDENTIAL PLAN CHECKT,Tq'r (2003 Yntern.ational Residential Cade)-- Date: .3�, Project: r(,�„y. Zoning: 4Ae' Number of Storie Building Permit Number: Job Address, ��-�/� �,,� � � �, � so Basement:Ves Na / Frn<!ED nfm Fixtures: (Note unfinished bas encs as special conditon on permit) Floor Area (sf): fxn'shed, ,�'' unfuiisbed, ol arae Mechanical Fee: „_ The following comments based on the 2003 edition of the lntemafionalXTZ71 Residential Code should be resolved before a build�t�.g permit is'issued,bui�diri� V d specifications does not permit the V1 This cOr-rection list is not a . The approval of plans and violation of any section of the lntema�ic�t�pe��� state or Joeat -regulations.al esidential Code or any federal, PLAN CHECK A. Plans �To Scale Plot Plan �`� Legible Y / N Flood Plain %p Floor 1 'Foundation Plan .... —Section showingL construction details �A1.I Bui�d�.n 9 Elevations sign CrY�.er1a (shall be identified on --------- Truss Calculation plans as Wind - 85 m.p.h., Snow -.3,-5 1b. Per sq ft.) Sheets & .-FloorJoi WL A Details Mechanical Design /Energy Calculations (8320 & Ch 11) B. Zoning (circle one, –new zoning designations adopted m" 2005) LDR1 12,000 Z::� sfmmll. ft. min) �R� 8,000 Sf Mm. (width 60 ft* n); Duplex 10,000min);RR2 21780 sf min. sq, ft. min. with C.U.P. (width 150 ft min) Duplex allowed With C.U.P. Other (Verify zoning -requixeme-nts) C. Use ,/�Sxng�.e Family ���..g�pfe��� only - Conclitional use ez�m�t? D. Set Backs (taken from eaves) .Z'Front set hack (32 ft. from curb) Note: 60% min of front yard greed ✓Rear set back (LDRI 25 ft. & LDR2 20 ft.) des set backs (6" for every ft, of building height with LDR - 7.5'min, & LDRI - Gmin.) ko-," Buiming-Hei�h� �maxir�um 3 a ft. E. Footings ''Proper Size (as per Table 403.1,,. use 1500 psf mess soil type is known, Table 401.4A for soil bearing) -z . Rebar [2-#4 continuous} ke"*"Footing Depth (36" below finiashed grade and 124" below undisturbed soil; 1 $" to top of slab -- interior) F, Foundation v''F'oundation walls wl rebar (city ordinance) /112" 'Anchor Bolts with 2"x 2'7x 3/16 square washers (inel. interior bearing wa1Is) R4a3.1.GJ .se dation Drainage (foundations on gift soit shall be designed per R40:5) Darn roofing/Waterproofing to f�.sh grade. R406.1 (fnd. extends 6"' min above grade R404.1.6) i s� ace access of � S" � 24"min. R40S.3 (may differ if r�.a.ech appliance is in crawl space M�30 5.1.4} Craw p C�a-entilatioxal�ia.su��.tion —1 sf vent pear 150 s�: ,�w�.th :moisture barrier 1 f er � 5�0 �s�.ftt.) and w��hin 3' of each career(insulate wars vent to inside of hoiniq) R408.2 - rte' borading slope away from - pause. 8401.3 G. Yrame �oislme Hold. Downs and Braced Wall Panels (R.602.14) Floors joists sized as per R502.3 Wood I foists sized per manufr. `Joists Under Load Bearing Partitions shall be doubled. R502*4 �- Girders sized per R502.5 or per manufr- Tables for engineered -products Ca'fifileveis (comply with R5'023*3 or manufr ins�ruGtran� IL Floor Sheathing (3/4" min for jois ts 24" oc & 5/8"" f-orj*oists 16" oc) R503.2-.2 /Wall (bearing and nonbearing) stud sizes, height & spacing per Table 601.31(5) 86023 Headers fi-i Bearing Wall shall be designed as per Tables 502.x(1 &2) R602-07 RoofTrusses (designed according to R802.10.1).'35 # Snow "Rafter and Truss tie -downs. (8802.10.5) JAttic Access 22" x 30" min. opening (8807) and 90 mph lAznds (Local Conditions) H.Exteri or Covering Masonry and stucco shall have weather resistive barfier over exterior she Y. Roof Covering and Ventilation woof Ventilation as per R806 O' Asphalt Shingles (slope>2 hing 8703.2 & 703.9.1 _,/111� :12) �,rl ice protection. (Other type: to comply W1 J. Firewalls '0 GaragelHouse drywall separation (protect ext. walls & beams supporting habitable space) 8309.2 Door from. Garage to House (1 3/811 solid mood or steed door, or 20 min. fire -rated door) 8309,1 Trm-E-onily.,Dwelling Separation (Z hr fire separation) Supporting structure also rated. R317.1 Townhouses (Z her separation & 4.' flverburn protection or parapet) -R3I7.2 ��.e-hr-wal}s-�aralleX to and within 3 kof property lime Irl NO openings. R302 Uak an PrevlOus 3 %'items to comply with R3 x.7.3 K. neral Requirements Douse Numbers R321 '�Half Openable 3 s� windowor -.Meeh. Inteii Ventilation in batbiooms, water closets, and similar rooms. 8343.3 or and exte�lor stair illumination shall comply with 8303.6. koobatbroom Fixture clearances comply with Figure R307,2 �Un� room at least X20 sf.; �Qt��er habitable roomsdi. 70 �f. min �vl a m7.n. mens�an of 7 ft.1�304 *areas w1slaped ceilings less than S ft in height &Jurred ceilings less than � fl- DO NOT comply .� ��o ur i-nure uJ me requarea area must be at 14 ast 7ft high in roc+ins w/ sloj7ed ceiling window wells index cantilevered floors. 1:1310.24.00 E ens clearance from .......... G�azing at Hazardous Locations R308 /v,- Egress in a�� sleeping rooms and basements writh habitable space 8310 -------------- �ne required Emit Door shall comply with 8311.4 `Landings at top and bottom of stair -ways 12311.5.4, and each sidl6n.� of each exterior door, 8.311.4.3 Stair Rise /Run (7 314" max. rise & I 0" mom. tread, nosing r+�q'ci 10f X11") � " Stair Width (36" Min), a tairway Headroom (68" min.) .'=JHandrails (3 4 "to 3 8 " above stair nosing) (R311.5) Specinl'oonditions for circular, spiral and winder stairways and -bulkhead enclosures R311-5-8 StairwayProtection (enclosed accessible space under stars shall be covered tivXth 112" dr all) R311.Z.Z ,Guardrails complying with R312 Smoke Alarms� each bedroom and co non area and one an eai-h level) (R 313) Energy . 'Homes withBazin 15 % of grass area of ext. walls (Townho uses < 25 %) to comply w/Chapter 11. Otherwise shall meet requirements a, f IECC fog respective bifilding type. NI 10 1*2 W//"Vapor retarder on warm in winter side of walls, ceding and floors R318 Z*Water I-leater.heat traps IECC 504.7 �uct seali.ng and insulationN1ID3.3&4 or IECC 5D3.3.3.3, 503.3.3.4.3 Plans match quantities & values on a "passing-) REScheek compl'iance repQrt .. M. Mechanical Gas appliances not in bedrooms, bathrooms, toilet roams, or storage closets G2406.2 Room access 24" min widthlAitic access clear opening 200WJnder floor r.o. 222,x300 M1305 XT)ryr Vint len h 25' maw wl S' transition (-5' per 9Q deg tur�as)1VI15U�..3 e� Flus chase shown on plans (B -vents not to be inside*nsulated walls without insulation shield}