Loading...
HomeMy WebLinkAboutRESCHECK - 07-00276 - 279 Polo Dr - New SFRt 13 0700276 279 Polo Dr-R Hill Const REScheck Compliance Certificate Checked By/Date 2000 IECC REScheckSoftware Version 3.6 Release 1 Data filename: C:1Program FileslChecklREScheck)Parkinson Residence.rck PROJECT TITLE: Parkinson Residence CITY: Rexburg STATE: Idaho HDD: 8693 CONSTRUCTION TYPE: Single Family WINDOW / WALL RATIO: 0.10 DATE: 06/06/05 DATE OF PLANS: June 21, 2005 PROJECT DESCRIPTION: 1540 SF Ranch DESIGNER/CONTRACTOR: R Hill Construction COMPLIANCE: Passes Maximum UA = 362 Your Horne UA = 323 10.8% Better Than Code (UA) Gross Glazing Area or Cavity Cont. or Door Pe-riniet R--Vglue R e VA Ceiling 1: Flat Ceiling or Scissor Truss 1540 38.0 0.0 46 o 4- Wall 1: Steel Frame, 24" o.c. 1512 2 22.0 0.0 111 Window 1: Vinyl Frame -Double Pane with Low E 115 0.340 39 Door 1: Glass 40 0.500 20 Door 2: Solid 47 0.160 8 Basement Wall 1: Solid Concrete or Masonry 1540 13.0 0.0 91 Wall height: 8.0' Depth below grade: 7.0' Insulation depth: 8.W Floor 1: All -Wood Joist/Truss:Over Outside Air 189 22.0 0.0 8 Furnace 1: Forced Hot Air, 92 AFUE Air Conditioner 1: Electric Central Air, 10 SEER COMPLIANCE STATEMENT: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in RES checkVersion 3.6 Release 1 mandatory requiremen ted in the RES heckInspection Checklist. Builder/Designer (formerly NEC check) and to comply with the Date / i - d a REScheck Inspection Checklist 2000 IECC REScheckSoflware Version 3.6 Release 1 DATE: 06/06/05 PROJECT TITLE: Parkinson Residence Bldg. Dept. Use Ceilings• [ ] I 1. Ceiling 1: FIat Ceiling or Scissor Truss, R-38.0 cavity insulation Comments: I Above -Grade Walls: [ ] I 1. Wall 1: Steel Frame, 24" o.c., R-22.0 cavity insulation I Comments: I Basement Walls: [ ] I 1. Basement Wall 1: Solid Concrete or Masonry, 8.0' ht/7.0' bg18.0' instil, I R-13.0 cavity insulation I Comments: I I Windows: L J I 1. Window 1: Vinyl Frame:Double Pane with Low-E, U factor: 0.340 j For windows without labeled U-factors, describe features: I # Panes Frame Type Thermal Break? [ ] Yes [ ] No j Comments: I I Doors: [ J I 1. Door 1: Glass, U factor: 0.500 I Continents: j ] I 2. Door 2: Solid, U-factor: 0.160 I Comments: I Floors: [ ] I 1. Floor 1: All -Wood Joist/Truss:Over Outside Air, R-2.2.0 cavity insulation Comments: I Heating and Cooling Equipment: [ ] I 1. Furnace 1: Forced Hot Air, 92 AFUE or higher I Make and Model Number [ ] j 2. Air Conditioner 1: Electric Central Air, 10 SEER or higher Make and Model Number I Air Leakage: [ ] I Joints, penetrations, and all other such openings in the building envelope that are sources of air j leakage must be sealed. [ ] I Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly