HomeMy WebLinkAboutMISC DOCS - 07-00204-00205 - BYUI Dry Storage - New Building - Site PlanJO 74P 16 July 17, 2007 Rulon Nielsen 450 S Physical Plant Way Rexburg, Idaho 83440 Dear Mr. Nielsen, CIT V F RExBu-P 6fi � Fafiiji1v #l? Oil -2 / / ) �� -? I r'- --t 1--r- I . 1cr 1 1, Thank you for submi.aing a respQnse to our rev-iew notes for your subrri-itted plans, Tha-flk you for the clar�.f�cation provided on several of the concerns that staff had. Afterre��ieurxr�g the submitted material and responses, I believe these are only a couple of issues that need to be xesalved ox clarified prior to obtain�.tzg approval. Born the Plannin Deparent.�Those issues axe described in. the following body of this lette,t. g Rega-rding adequate screerung of the sits, these needs to be anon-seasonal screenmof taus site Mostly in the formofvegetation. with the deciduous trees and shrubs, thesite would be clearly Visible for the majority of the year. Axe there any dwarf spruces or others that only gnaw to about 15 -feet in height that could be used? Does a Dwarf Alberta Spruce work for our area? Do( -:s a Mugho Pine -Rostrata work for our area? Is there a way to have a balance of deciduous trees and the use opaque fenangP This mi ht uToxk on north side of the ptoper-Ly where you mould like to maxixni�e solar access to g P-tevent ti�,�tex ice build-up an the adjacent sidewalks. Rogatding the installation of landscapiza.g, a tempoxa-tr certificate of occupancy could be issued upon the completion of the buildqig. A final certificate of occupancy can be issued after any waresatved, non -life and safe �T issues are resolved, such as installation of landsca,��.r�g. During e �cvinte� months, we have issued temporary- ce-rtificates of occupancy with the condition the proposed landscaping be Mstalled byjune Vt of the next summer. Finally, in my commellts regarding delineation of proposed landscaped axeas, I or�.IY ave areas designated by a highlighter penwhereas we would nrPfP�- ��,P.-;�,- „Ya,,.. 11..,:. _ for future xeferencang. Gary Leik-ness 11 and Zoe- �i trtar - --- t-_-..�•..� ..t,�.41I.L4 ait.aS uG.L!_t�iI CLCLI 12 N.Center u% ID 83440 PJ 0 (208) . , ' e 1 Fav _5 ._3024 gag'q- O 7v- Orz Box 280 Thank you for the time you have spent on this thus fay. I zeallV think that working out a solution With the design review comtxlittee (ID -RC) i's 901 -ng to Woxk out. The det0s just need to be hammered out to ensure that the intent of the DRC is followed. Sincelely., Gary Lelkness Plannaig and honing Administ-rator F Llanning and Zoamg Adauimistrator 12 X Center Rexburg ID S_3440 P. 0. Box 2,90 One (208) 59.3020 ext 3 14 Fax_359 9agl@rexbAfrg. Or +, . Org ontact Loilt, Initialed 19 E. Main Rexburg., ID 8344- Building Safety Department City of Rexburg jcneYh@rexbu-rn orn t 326 J t . r Fox: r � � Office FIours: Monday -Friday 8:00atn-4:00pm I' RExBuRG Commercial/Multi Family Pre-Construction Checklist Seismic Design'Category -- D (unless soil evaluation confirms category C) Ground Snow �- 50 lbs. p'e'r sq, ft. Roof Snow Load — 351bs. per sq. ft. Wind Load — 90 MPH Frost Depth — 36" Thef011owing items shozit'd he completed before ya�� submityour Ntilding_permit ap licalion. COmpletion of Buifding Perrnit Applfcatratl. you mayr print this application frorr� our website www,rexbuzg�or� or pick up a copy at the City Annex BLffldinv(address above). C0MMeTCiaIPernVts: (the following must be submitted vcr�.th the Application) Q 4 sits of site plans and .� sets of builcling plans stamped by a licensed professional LJ S'teiplans and building plans in PDF format Structutal Calculations stamped by a licensed Engineer 11 Energv CotYlfilFf�7#lr� � sar..-.rt. ❑ _ snn•f TT /ti!'+i � _. _ 01 01 1 !J --�,�--�_==ruw,�L�- �,Gr ane ��u.� �..C,c��a [Jamplsance check must be completed and suUmitted (the comcheck is available online at w�ww,ener codes. ov). Please complete the envelope, mechanical & liorbtinor cPr-t�.�,.,� Page 2 of the Application must include the Idaho C must be completed and sem, see Page 9. Page 4 of the ApphcatlOn must be completed and si License is required for out files. Page 5 of the APPlica�ioa� must �e camp�eted by s� mechanical License is required for our files, Mechanical system sizing and. design Page 6 of the Application. must lie completed and sl' Electrician's License is xequired dor our files. ntractor's Registration Number or the exemption form ed b ed b ed U our Plumber. A ropy of the Plumber"s our Mechlanical Contractor, a copy of the our Electrician. A copy of the �.1�.►-C.�l�,�i Myc,L L must De lnclucied with the n buildinsy nlar�q n�iaQ�;gill hn .I�.o:r;.,..__�--prior to issuance of the buildir�g permit.Emergency Services Construetian PermitLighting Plan �, . � 1N1147 .�,,,. �,�, It, ,,1�N„�u „ y Li 1 e �lectrical inspector E]CctficalPe"nils are now issued through the City of Rexburg. See Page G of the application. Remodels: f f you are cansidcrin.g a rcniode], a CODY of the bid or estimate dor the remodel niust be SuUrUtted with the Permit Application, • 2 sct of plans (may need TECC Review) Additions — Sams as new construction I City of Rexburg -- PI, Permit Number: 07 00204 Project Name: BYU-Idaho Dry Storage Replacement Building Project Type: Site Plan Review 00204 & 07 00205 BYUI -Dry Stora ge B", Id I P Revisions 6/14/07 I to 0 �L" tv i�+4 il�4 66 . 56'* 1 City of Rexburg -- Plan Review Permit Number: 07 00204 Project Name: 8YU-Idaho Dry Storage Replacement Building Project Type: Site Plan Review Review Item- Actions Rqd. For Approval Approved BYU-Idaho Response Fire9ept.-, Review Fire apparatus Access Access via public roadway. If gated 05/09/2007 Gates are not lacked. A KNOX fax will a & locked, a KNOX box would be be attached to the building. recommended Vicinity map provided Provided 05/09/2007 Fire hand Signage Not Required 05/Q9/20U7 Access to Hydrants Provided.. 05/09/2007 Fire sprinkler system Not Required a5/09/2007 required Existing hydrants Square footage of 8 00 Sq.Ft., Type IIB construction, Occupancy Table B105.1 (appendix B} was used to S2, requires a minimum of 2000 Qbtaing the 2D00 QPM flow GPM/two hours from two hydrants requirement. Q new fire hydrant will within 45� Ft. of proposed be installed. See revised plans structure. Nearest fire hydrant is approx. 225 fit. from proposed structure. The next nearest hydrant is 545 fit. away Hydrant flows provided I No hydrant flows provided Hydrants an 1St West, fed from city ling have flows of 1290 & 1210 GPMProposed hydrants Plans show no proposed hydrants Anew fire hydrant wild be installed. See to meet minimum fire flow revised plans. requirements Required'fire flow Rqd. Fire flow of 2000GPM. Anew fire hydrant will be installed.. See Additional fire hydrant required revised plans. within travel distances City of Rexburg -- Plan Review Permit Number: 07 00204 Project dame: BYU-Idaho Dry Storage'eplacement Building Project Type: Site Flan Review Review Item Actions Rqd. For Approval Approved BYU-Idaho Response Planning Staff review Approved Site Pian Better elevations of all sides are See attached sheet needed for determination of University District setback requirements and other buffering elements. C ity of Rexburg -- Plan Review Permit Number-, 07 00204 Project dame: NYU -Idaho Dry Storage Replacement Building traject Type: Site Plan Review City of Rexburg -- Plan Review Permit Number-. 47 00204 Project Name; BYU-Idaho Dry Storage Replacement Building Project Type: Commercial Addition Review item Actions Rqd. For Approval Approved BYU-1daho Response Administrative Review Permit Tech Notes Genera! Contractor information general contractor is Double E required prior to issuance of Construction of Ririe, Idaho. Contact is building permit. Electrical Richard Elis (589-5511,), General contractor information and contractor will complete the application signature needed papers. C ity of Rexburg -- Plan Review Permit Number.- 07 00204 Project Name: BYU--ldaho Dry Storage Replacement Building Project Type: Commercial Addition Review Item Actions Rqd. For Approval- Approved BYU-Idaho Response Building Dept. Review Electrical Service Review =05/(9/�af]7 Electrical Circuity Review No circuits were submitted. If any (15f09/2007 See sheet 14 of attachedfa 125V, 15 or 20 amp receptacles are p n installed they reed to be GFCI protected. Approved with the exception that everything is installed to the 200-5 ITEC requirements Water & Sewer Service A!1 plumbing services are required to 05/09/2007 No water or sewer work is included be installed, tested and inspected in project. before covering. Plumbing Sewer Drain None shown 'on plans. ASI plumbing is 05/09/2007 No floor drains are included in this review required to be approved before project installing. Any floor drains in storage area require a separator. No drains shown an plans. Plumbing Storm Drain Al! storm water piping is required to [15J0912007 See note 3, sheet 4 of plans Review be tested and inspected before covering. Plumbing Potable Water Alfwafe.r piping is required to be Review 05/09/2007 No new water lines in project. tested and inspected before covering. None shown on plans. Building Code Fire Fire separation from other buildings is 05f09/2007 Thank you. Compliance Review not required Accessibility Review Provide floor plan., ASI bays have 3'walk-in door with correct clearance an knob side. Na steps or ramps will exist. (see sheet 10 of plans) Building Type Compliance Building is. Type 1113 Type 11B Exing Review Provide floor plan All bays have 3 -walk-in door. see sheet 10j Mechanical Review Please provide mechanical sizing and No mechanical systems details Structural review Please provide stamped structural Erection subcontractor will provide plans for building and foundation. prior to construction Special Enspeciions are required dor foundation, high strength bolting and any welding, Height- & Area Review Height and area meed code anc Occupancy is 51(Storage of bags,, requirements unless the occupancy is furniture, glues, lumber, flooring, N. Please provide Dist of items being soap, upholstery, cement.. gypsum stared and type of work that will be board, metal cabinets, metals, performed in building. washer &dryers, etc. City of Rexburg Mff* Plan Review Permit Number: 07 00204 Project Name: BYU-Jdaho Dry 5tarage Replacement Building Project Type: Commercial Addition Review Item I Actions Rqd. For Approval Energy Conservation Cvmpliance Review Is the building heated? If so, please provide energy review. Approved I BYU-Idaho Response Building is not heated aia C ity of Rexburg -- Plan Review Permit Number: 07 00204 Project Name: BYU-idaho dry Storage Replacement Building Project Type: Commercial Addition Review Item Actions Rqd. For Approval Fire Dept. Review Required Fire Flaw See site pian review Water supply See site pian review Fire Access Roads See site plan review .. Fire Extinguishers Building requires extinguishers. Minimum of 2A1013C extinguishers will be required Automatic Fimre--- Building will be required to be Extinghishing Systems sprinklered :"f storage is over 12 ft. tailor over 6 ft. with plastics. If sprinklers are required letter of intent from certified fire sprinkler contractor is required. Standpipes I N /A- Commercial evoking N/A Alarm Systems Alarm system will be required if fire sprinkler system is installed. Approved I BYU-Idaho Response 05/15/2007 a5/islzao7 05/15/2007 One approved extinguisher wil be provided in each bay Storage will not be over 12' high N/A N/A dire sprinkler system not required Site Plan Review Checklis. Project. Permit # Zone: ()D Surrounding Land Uses: Elevations submifted: Landscape Plan submitted: Lighting Plan submitted: q.t 0