HomeMy WebLinkAboutRESCHECK - 21-00247 - 1133 Greenside Loop - New SFRREScheck Software Version 4.7.0 Compliance Certificate Project Sommer Residence Energy Code:2009 IECC Location:Rexburg, Idaho Construction Type:Single-family Project Type:New Construction Conditioned Floor Area:2,179 ft2 Glazing Area 14% Climate Zone:6 (8693 HDD) Permit Date: Construction Site: Lot 4 Block 1 Pinebrook Estates Rexburg, ID Owner/Agent: Sommer Lot 4 Block 1 Rexburg, ID Designer/Contractor: Craig Wall Design 7707 South Main Midvale, UT Permit Number: Compliance: Passes using UA trade-off 2.6% Better Than Code Maximum UA:302 Your UA:294 The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Compliance: Envelope Assemblies Assembly Gross Area or Perimeter Cavity R-Value Cont. R-Value U-Factor UA All Roof Over Living Area: Flat Ceiling or Scissor Truss 2,179 42.0 0.0 0.028 61 Front (Northeast Facing) Walls: Masonry Block with Integral Insulation:w/ Additional Interior Insulation 505 22.0 0.0 0.053 21 Front Windows: Vinyl/Fiberglass Frame:Double Pane with Low-E 60 0.310 19 Garage Man Door Insulated: Solid 20 0.340 7 Front Entry: Glass 20 0.350 7 Right (Northwest Facing) Walls: Masonry Block with Integral Insulation:w/ Additional Interior Insulation 358 22.0 0.0 0.053 18 Right Side Windows: Vinyl/Fiberglass Frame:Double Pane with Low-E 18 0.310 6 Rear (Southwest Facing) Walls: Masonry Block with Integral Insulation:w/ Additional Interior Insulation 459 22.0 0.0 0.053 19 Rear Windows: Vinyl/Fiberglass Frame:Double Pane with Low-E 57 0.310 18 Door 3: Glass 40 0.350 14 Left (Southeast Facing) Walls: Masonry Block with Integral Insulation:w/ Additional Interior Insulation 407 22.0 0.0 0.053 19 Left Side Windows: Vinyl/Fiberglass Frame:Double Pane with Low-E 50 0.310 16 Floor 1: All-Wood Joist/Truss:Over Unconditioned Space 2,094 30.0 0.0 0.033 69 Project Title: Sommer Residence Data filename: G:\Shared drives\CWD Projects\01-CURRENT\Sommer\Sommer's ResCheck.rck Page 1 of 8 04/13/21Report date: Name - Title Signature Date Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2009 IECC requirements in REScheck Version 4.7.0 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Project Title: Sommer Residence Data filename: G:\Shared drives\CWD Projects\01-CURRENT\Sommer\Sommer's ResCheck.rck Page 2 of 8 04/13/21Report date: Mark Martin- Designer 4/13/21 Inspection Checklist Requirements: 0.0% were addressed directly in the REScheck software REScheck Software Version 4.7.0 Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Energy Code: 2009 IECC Section # & Req.ID Pre-Inspection/Plan Review Plans Verified Value Field Verified Value Complies?Comments/Assumptions 103.2 [PR1]1 Construction drawings and documentation demonstrate energy code compliance for the building envelope. Complies Does Not Not Observable Not Applicable 103.2, 403.7 [PR3]1 Construction drawings and documentation demonstrate energy code compliance for lighting and mechanical systems. Systems serving multiple dwelling units must demonstrate compliance with the commercial code. Complies Does Not Not Observable Not Applicable 403.6 [PR2]2 Heating and cooling equipment is sized per ACCA Manual S based on loads per ACCA Manual J or other approved methods. Heating: Btu/hr_____ Cooling: Btu/hr_____ Heating: Btu/hr_____ Cooling: Btu/hr_____ Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Sommer Residence Data filename: G:\Shared drives\CWD Projects\01-CURRENT\Sommer\Sommer's ResCheck.rck Page 3 of 8 04/13/21Report date: Section # & Req.ID Foundation Inspection Complies?Comments/Assumptions 303.2.1 [FO11]2 A protective covering is installed to protect exposed exterior insulation and extends a minimum of 6 in. below grade. Complies Does Not Not Observable Not Applicable 403.8 [FO12]2 Snow- and ice-melting system controls installed. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Sommer Residence Data filename: G:\Shared drives\CWD Projects\01-CURRENT\Sommer\Sommer's ResCheck.rck Page 4 of 8 04/13/21Report date: Section # & Req.ID Framing / Rough-In Inspection Plans Verified Value Field Verified Value Complies?Comments/Assumptions 402.1.1, 402.3.4 [FR1]1 Door U-factor.U-_____U-_____Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 402.1.1, 402.3.1, 402.3.3, 402.5 [FR2]1 Glazing U-factor (area-weighted average). U-_____U-_____Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 303.1.3 [FR4]1 U-factors of fenestration products are determined in accordance with the NFRC test procedure or taken from the default table. Complies Does Not Not Observable Not Applicable 402.4.4 [FR20]1 Fenestration that is not site built is listed and labeled as meeting AAMA/WDMA/CSA 101/I.S.2/A440 or has infiltration rates per NFRC 400 that do not exceed code limits. Complies Does Not Not Observable Not Applicable 402.4.5 [FR16]2 IC-rated recessed lighting fixtures sealed at housing/interior finish and labeled to indicate ≤2.0 cfm leakage at 75 Pa. Complies Does Not Not Observable Not Applicable 403.2.1 [FR12]1 Supply ducts in attics are insulated to ≥R-8. All other ducts in unconditioned spaces or outside the building envelope are insulated to ≥R-6. R-_____ R-_____ R-_____ R-_____ Complies Does Not Not Observable Not Applicable 403.2.2 [FR13]1 All joints and seams of air ducts, air handlers, filter boxes, and building cavities used as return ducts are sealed. Complies Does Not Not Observable Not Applicable 403.2.3 [FR15]3 Building cavities are not used for supply ducts. Complies Does Not Not Observable Not Applicable 403.3 [FR17]2 HVAC piping conveying fluids above 105 ºF or chilled fluids below 55 ºF are insulated to ≥R- 3. R-_____R-_____Complies Does Not Not Observable Not Applicable 403.4 [FR18]2 Circulating service hot water pipes are insulated to R-2. R-_____R-_____Complies Does Not Not Observable Not Applicable 403.5 [FR19]2 Automatic or gravity dampers are installed on all outdoor air intakes and exhausts. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Sommer Residence Data filename: G:\Shared drives\CWD Projects\01-CURRENT\Sommer\Sommer's ResCheck.rck Page 5 of 8 04/13/21Report date: Section # & Req.ID Insulation Inspection Plans Verified Value Field Verified Value Complies?Comments/Assumptions 303.1 [IN13]2 All installed insulation is labeled or the installed R-values provided. Complies Does Not Not Observable Not Applicable 402.1.1, 402.2.5, 402.2.6 [IN1]1 Floor insulation R-value.R-_____ Wood Steel R-_____ Wood Steel Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 303.2, 402.2.6 [IN2]1 Floor insulation installed per manufacturer’s instructions, and in substantial contact with the underside of the subfloor. Complies Does Not Not Observable Not Applicable 402.1.1, 402.2.4, 402.2.5 [IN3]1 Wall insulation R-value. If this is a mass wall with at least ½ of the wall insulation on the wall exterior, the exterior insulation requirement applies. R-_____ Wood Mass Steel R-_____ Wood Mass Steel Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 303.2 [IN4]1 Wall insulation is installed per manufacturer’s instructions. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Sommer Residence Data filename: G:\Shared drives\CWD Projects\01-CURRENT\Sommer\Sommer's ResCheck.rck Page 6 of 8 04/13/21Report date: Section # & Req.ID Final Inspection Provisions Plans Verified Value Field Verified Value Complies?Comments/Assumptions 402.1.1, 402.2.1, 402.2.2 [FI1]1 Ceiling insulation R-value. Where > R-30 is required, R-30 can be used if insulation is not compressed at eaves. R-30 may be used for 500 ft² or 20% (whichever is less) where sufficient space is not available. R-_____ Wood Steel R-_____ Wood Steel Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 303.1.1.1, 303.2 [FI2]1 Ceiling insulation installed per manufacturer’s instructions. Blown insulation marked every 300 ft². Complies Does Not Not Observable Not Applicable 402.2.3 [FI3]1 Attic access hatch and door insulation ≥R-value of the adjacent assembly. R-_____R-_____Complies Does Not Not Observable Not Applicable 402.4.2, 402.4.2.1 [FI17]1 Building envelope tightness verified by blower door test result of <7 ACH at 50 Pa. This requirement may instead be met via visual inspection, in which case verification may need to occur during Insulation Inspection. ACH 50 =_____ACH 50 =_____Complies Does Not Not Observable Not Applicable 403.2.2 [FI4]1 Post construction duct tightness test result of ≤8 cfm to outdoors, or ≤12 cfm across systems. Or, rough-in test result of ≤6 cfm across systems or ≤4 cfm without air handler. Rough-in test verification may need to occur during Framing Inspection. _____ cfm _____ cfm Complies Does Not Not Observable Not Applicable 403.1.1 [FI9]2 Programmable thermostats installed on forced air furnaces. Complies Does Not Not Observable Not Applicable 403.1.2 [FI10]2 Heat pump thermostat installed on heat pumps. Complies Does Not Not Observable Not Applicable 403.4 [FI11]2 Circulating service hot water systems have automatic or accessible manual controls. Complies Does Not Not Observable Not Applicable 404.1 [FI6]1 50% of lamps in permanent fixtures are high efficacy lamps. Complies Does Not Not Observable Not Applicable 401.3 [FI7]2 Compliance certificate posted.Complies Does Not Not Observable Not Applicable 303.3 [FI18]3 Manufacturer manuals for mechanical and water heating equipment have been provided. Complies Does Not Not Observable Not Applicable Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Sommer Residence Data filename: G:\Shared drives\CWD Projects\01-CURRENT\Sommer\Sommer's ResCheck.rck Page 7 of 8 04/13/21Report date: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: Sommer Residence Data filename: G:\Shared drives\CWD Projects\01-CURRENT\Sommer\Sommer's ResCheck.rck Page 8 of 8 04/13/21Report date: 2009 IECC Energy Efficiency Certificate Insulation Rating R-Value 22.00Above-Grade Wall 0.00Below-Grade Wall 30.00Floor 42.00Ceiling / Roof _______Ductwork (unconditioned spaces): Glass & Door Rating SHGCU-Factor 0.31Window 0.35Door Heating & Cooling Equipment Efficiency _______Heating System:_________________________ _______Cooling System:_________________________ _______Water Heater:___________________________ Name:Date: Comments