HomeMy WebLinkAboutPLANS - 21-00247 - 1133 Greenside Loop - New SFRNORTH SCALE 1"=10'SITE PLAN
2
0
4
.
2
1
'
P
R
O
P
E
R
T
Y
L
I
N
E
50
.
0
7
'
P
R
O
P
E
R
T
Y
L
I
N
E
146.19' PROPERTY LINE
1
8
0
.
1
1
'
P
R
O
P
E
R
T
Y
L
I
N
E
6 4 .1 8 ' P R O P E R T Y L I N E
GA
R
A
G
E
T
.
O
.
S
.
=
9
8
'
-
6
"
MA
I
N
F
.
F
.
=
1
0
0
'
-0"
SETBACK PER CITY CODE 4.02.080
13'-0"
S
E
T
B
A
C
K
2
0
'
-
0
"
S E T B A C K
2 0 '-0 "
S E T B A C K P E R C I T Y C O D E 4 .0 2 .0 8 013'-0 "
S E T B A C K25'-0 "
CO
N
C
R
E
T
E
DR
I
V
E
S
L
O
P
E
50'-1 1/8"
28'-7 3/4"
1
0
0
'
-
2
1
/
8
"
1
1
9
'
-
1
0
5
/
8
"
18'-2 3/4"
14'-4 3/4"2 5 '-5 1 /2 "4 9 '-2 3 /8 "
33'-9 1/8"
5
4
'
-
6
3
/
8
"
48'-6 1/2"97'-7 3/4"
24
'
-
0
3
/
4
"
26'
-
0
"
1
0
4
'
-
2
1
/
4
"
7 5 '-1 0 "2 4 '-2 1 /4 "
2 9 '-9 7 /8 "
4 6 '-1 1 /2 "
3 9 '-6 3 /8 "
2 2 '-0 3 /4 "
4 2 '-6 3 /4 "project:revisions:Project number Date Drawn by Engineered by7707 SOUTH MAIN STREET MIDVALE, UT 84047 801.285.8885CRAIG WALL DESIGN EACH SUB-CONTRACTOR SHALL CHECK AND UNDERSTAND ALL DIMENSIONS, NOTES AND OTHER ASPECTS OF THIS PROJECT APPLICABLE TO THEIR TRADE AND AFFECTING OTHER TRADES PRIOR TO AND DURING CONSTRUCTION.NOTIFY DESIGNER OR ENGINEER IN WRITING OF ANY DISCREPANCIES OR CHANGES ON THE DRAWINGS BEFORE PROCEEDING WITH ANY WORK.EACH SUB-CONTRACTOR SHALL COORDINATE WORK WITH OTHER TRADE THROUGH THE GENERAL CONTRACTOR.THE DESIGNER WILL NOT ASSUME RESPONSIBILITY FOR ANY MISUSE OR MISREADING OF THESE PLANS. WHERE INFORMATION IS AVAILABLE BUT UNCLEAR, THE PERSON USING THESE PLANS IS RESPONSIBLE FOR CLARIFYING ANY QUESTIONS ACCORDING TO THE CONDITIONS STATED ABOVE.C1.0MARCH 26, 2021SOMMER RESIDENCE LOT 4 BLOCK 1 PINE BROOK ESTATES REXBURG, ID CWD N/A SITE PLANNOTES:1. DRIVEWAY SHALL BE GRADED SUCH THAT WATER DRAIN ING OFF THE DRIVE DOES NOT FLOW ONTO THE ROAD AND IS DIVERTED INTO A ROADSIDE DITCH OR G UTTER. 2. MIN. DRIVEWAY FLARES TO BE 2'-0" AS REQ'D BY C ODE. 3. HOUSE DRAINAGE FINAL GRADES TO BE MIN. 6" OF F ALL FOR FIRST 10' FROM HOME. 4. LOT IS TO BE GRADED AND LANDSCAPED IN A MANNER THAT WILL PREVENT WATER RUNOFF FROM ADVERSELY AFFECTING ADJOINING PROPERTY LINES. 5. PROVIDE METALLIC WATER SERVICE & CONCRETE ENCA SED ELECTRODE PER 2017 NEC.6. ALL CONSTRUCTION TO COMPLY W/ THE 2018 INTERNA TIONAL BUILDING CODE.7. STORM DRAINAGE TO FLOW TO APPROVED STORM DRAIN SYSTEM. 8. PROVIDE ROAD BASE RAMP TO PROTECT PAVED ROAD, CURB AND SIDEWALK AS REQUIRED. 9. PROVIDE 1" WATER LINE TO HOUSE.10. DUST, MUD AND EROSION SHALL BE CONTROLLED BY WHATEVER MEANS NECESSARY, AND THE ROADWAY SHALL BE KEPT FREE OF MUD AND DEBRIS AT ALL TIMES.11. BUILDER/OWNER SHALL REPLACE ANY EXISTING SIDE WALK OR CURB & GUTTER ALONG THE FRONTAGE OF THIS PROJECT THAT IS FOUND TO BE DEFECT IVE, AS DIRECTED BY THE CITY INSPECTOR.12. SETBACKS ARE DETERMINED BY LOCAL ZONING ORDINA NCES.13. PROPERTY LINES AND SETBACKS VARY IN RELATIONSH IP TO THE STREET, SIDEWALK, ETC.14. VERIFY WITH BUILDING DEPT. AND / OR SURVEYOR F OR ACCURATE PLACEMENT OF STRUCTURE.15. SOME JURISDICTIONS REQUIRE MIN. DISTANCES BETW EEN ADJACENT STRUCTURES WHICH WILL OVERRIDE A SETBACK. VERIFY W/ LOCAL BUILDING / ZON ING DEP.16. VERIFY ALL HEIGHT RESTRICTIONS W/ LOCAL BUILDI NG / ZONING DEP.
MA
I
N
F
.
F
.
10
0
'
-0"
MAIN F.F.100'-0"
MA
I
N
T
O
P
P
L
A
T
E
10
9
'
-0"
MAIN TOP PLATE 109'-0"
GA
R
A
G
E
T
.
O
.
S
.
98
'
-6"
GARAGE T.O.S.98'-6"
A A5
.
1AA5
.
1
SC
A
L
E
1
/
4
"
=
1
'
-
0
"
FR
O
N
T
E
L
E
V
A
T
I
O
N
12
8
12
8
12
8
6'-8"
6
'
-
8
"
AR
C
H
I
T
E
C
T
U
R
A
L
S
H
I
N
G
L
E
S
BR
I
C
K
BR
I
C
K
BRICK25'-9 1/4"
12
8
12
8
MA
I
N
F
.
F
.
10
0
'
-0"
MAIN F.F.100'-0"
MA
I
N
T
O
P
P
L
A
T
E
10
9
'
-0"
MAIN TOP PLATE 109'-0"
FA
M
I
L
Y
R
O
O
M
T
.
P
.
11
1
'
-0"
GARAGE T.O.S.98'-6"
12
8
12
8
SC
A
L
E
1
/
4
"
=
1
'
-
0
"
LE
F
T
E
L
E
V
A
T
I
O
N
6
'
-
8
"
AR
C
H
I
T
E
C
T
U
R
A
L
S
H
I
N
G
L
E
S
BRICK
BR
I
C
K
BR
I
C
K
BR
I
C
K
PR
O
V
I
D
E
1
S
Q
.
F
T
.
O
F
A
T
T
I
C
S
P
A
C
E
V
E
N
T
I
L
A
T
I
O
N
FO
R
E
V
E
R
Y
1
5
0
S
Q
.
F
T
.
O
F
A
T
T
I
C
S
P
A
C
E
12 812 8 project:revisions:Project number Date Drawn by Engineered by7707 SOUTH MAIN STREET MIDVALE, UT 84047 801.285.8885CRAIG WALL DESIGN EACH SUB-CONTRACTOR SHALL CHECK AND UNDERSTAND ALL DIMENSIONS, NOTES AND OTHER ASPECTS OF THIS PROJECT APPLICABLE TO THEIR TRADE AND AFFECTING OTHER TRADES PRIOR TO AND DURING CONSTRUCTION.NOTIFY DESIGNER OR ENGINEER IN WRITING OF ANY DISCREPANCIES OR CHANGES ON THE DRAWINGS BEFORE PROCEEDING WITH ANY WORK.EACH SUB-CONTRACTOR SHALL COORDINATE WORK WITH OTHER TRADE THROUGH THE GENERAL CONTRACTOR.THE DESIGNER WILL NOT ASSUME RESPONSIBILITY FOR ANY MISUSE OR MISREADING OF THESE PLANS. WHERE INFORMATION IS AVAILABLE BUT UNCLEAR, THE PERSON USING THESE PLANS IS RESPONSIBLE FOR CLARIFYING ANY QUESTIONS ACCORDING TO THE CONDITIONS STATED ABOVE.A1.0MARCH 26, 2021SOMMER RESIDENCE LOT 4 BLOCK 1 PINE BROOK ESTATES REXBURG, ID CWD N/A EXTERIOR ELEVATIONSNOTES:1. EXTERIOR WALL FINISHES MUST BE LISTED, LABELED, AND INSTALLED AS PER MANUFACTURER'S INSTALLATION INSTRUCTION GUIDES.2. INSPECTION OF THE WEATHER-RESISTIVE BARRIER AND FLASHING IN ORDER TO PREVENT WATER FROM ENTERING THE WEATHER-RESISTANT EXTERIOR WALL ENVELOPE IS REQUIRED. R109.1.5 3. ALL FOOTINGS SHALL BEAR 30" OR 36" MIN. BELOW FINISH GRADE (VERIFY DEPTH WITH LOCAL CODES), BUT NO LESS THAN 12" BELOW NATURAL GRADE.4. HOUSE DRAINAGE FINAL GRADES TO BE MIN. 6" OF FALL FOR FIRST 10' FROM HOME.
MA
I
N
F
.
F
.
10
0
'
-0"
MAIN F.F.100'-0"
MA
I
N
T
O
P
P
L
A
T
E
10
9
'
-0"
MAIN TOP PLATE 109'-0"
FA
M
I
L
Y
R
O
O
M
T
.
P
.
11
1
'
-0"
FAMILY ROOM T.P.111'-0"GARAGE T.O.S.98'-6"
A A5
.
1AA5
.
1
12
8
12
8
12
8
SC
A
L
E
1
/
4
"
=
1
'
-
0
"
RE
A
R
E
L
E
V
A
T
I
O
N
6'-8"
6
'
-
8
"
1
'
-
0
"
2
'
-
0
"
AR
C
H
I
T
E
C
T
U
R
A
L
S
H
I
N
G
L
E
S
BR
I
C
K
PROVIDE 1 SQ. FT. OF ATTIC SPACE VENTILATION FOR EVERY 150 SQ. FT. OF ATTIC SPACE
BR
I
C
K
BR
I
C
K
BRICKBRICK128128
MA
I
N
F
.
F
.
10
0
'
-0"
MAIN F.F.100'-0"
MA
I
N
T
O
P
P
L
A
T
E
10
9
'
-0"
MAIN TOP PLATE 109'-0"FAMILY ROOM T.P.111'-0"
GA
R
A
G
E
T
.
O
.
S
.
98
'
-6"
12 8
12
8
SC
A
L
E
1
/
4
"
=
1
'
-
0
"
RIG
H
T
E
L
E
V
A
T
I
O
N
6
'
-
8
"
AR
C
H
I
T
E
C
T
U
R
A
L
S
H
I
N
G
L
E
S
BR
I
C
K
BR
I
C
K
BR
I
C
K
BRICK BRICK
12
8
12
8
project:revisions:Project number Date Drawn by Engineered by7707 SOUTH MAIN STREET MIDVALE, UT 84047 801.285.8885CRAIG WALL DESIGN EACH SUB-CONTRACTOR SHALL CHECK AND UNDERSTAND ALL DIMENSIONS, NOTES AND OTHER ASPECTS OF THIS PROJECT APPLICABLE TO THEIR TRADE AND AFFECTING OTHER TRADES PRIOR TO AND DURING CONSTRUCTION.NOTIFY DESIGNER OR ENGINEER IN WRITING OF ANY DISCREPANCIES OR CHANGES ON THE DRAWINGS BEFORE PROCEEDING WITH ANY WORK.EACH SUB-CONTRACTOR SHALL COORDINATE WORK WITH OTHER TRADE THROUGH THE GENERAL CONTRACTOR.THE DESIGNER WILL NOT ASSUME RESPONSIBILITY FOR ANY MISUSE OR MISREADING OF THESE PLANS. WHERE INFORMATION IS AVAILABLE BUT UNCLEAR, THE PERSON USING THESE PLANS IS RESPONSIBLE FOR CLARIFYING ANY QUESTIONS ACCORDING TO THE CONDITIONS STATED ABOVE.A1.1MARCH 26, 2021SOMMER RESIDENCE LOT 4 BLOCK 1 PINE BROOK ESTATES REXBURG, ID CWD N/A EXTERIOR ELEVATIONSNOTES:1. EXTERIOR WALL FINISHES MUST BE LISTED, LABELED, AND INSTALLED AS PER MANUFACTURER'S INSTALLATION INSTRUCTION GUIDES.2. INSPECTION OF THE WEATHER-RESISTIVE BARRIER AND FLASHING IN ORDER TO PREVENT WATER FROM ENTERING THE WEATHER-RESISTANT EXTERIOR WALL ENVELOPE IS REQUIRED. R109.1.5 3. ALL FOOTINGS SHALL BEAR 30" OR 36" MIN. BELOW FINISH GRADE (VERIFY DEPTH WITH LOCAL CODES), BUT NO LESS THAN 12" BELOW NATURAL GRADE.4. HOUSE DRAINAGE FINAL GRADES TO BE MIN. 6" OF FALL FOR FIRST 10' FROM HOME.
A
A5.1
AA5.1
20
9
2
S
Q
.
F
T
.
(
C
R
A
W
L
S
P
A
C
E
)
SC
A
L
E
1
/
4
"
=
1
'
-
0
"
FO
O
T
I
N
G
&
F
O
U
N
D
A
T
I
O
N
P
L
A
N
28
"
x
5
1
"
C
R
A
W
L
SP
A
C
E
A
C
C
E
S
S
CR
A
W
L
SP
A
C
E
NOTES:1. DO NOT PROVIDE LOOSE BACK FILL UNTIL FLOOR FRAMING & BASEMENT SLAB ARE IN PLACE &CONCRETE FOUNDATION WALLS HAVE ACHIEVED AT LEAST 75% OF DESIGN STRENGTHS OR 1750 PSI.(VERIFY NUMBER OF DAYS TO REACH DESIRED STRENGTH FROM CONCRETE PROVIDER).2. DO NOT PROVIDE COMPACTED BACK FILL UNTIL CONCRETE WALLS HAVE CURED AT LEAST 28 DAYS.3. COORDINATE WITH MECHANICAL AND OTHER SUBCONTRACTORS CONCERNING PERFORATIONS IN CONCRETE WALLS FOR DUCTWORK, ETC.4. PROVIDE 4" LEDGE AT FOUNDATION WALL FOR PORCH CAP (SUSPENDED OR OTHERWISE) W/ STEEL PER ENGINEERS SPECS. SEE DETAIL SHEET A5.0.5. CONTRACTOR AND / OR PLUMBER TO VERIFY ELEVATION OF SEWER LATERAL BEFORE EXCAVATION.6. GAS PIPE TO TIE TO MANIFOLD SYSTEM BY WHICH CODE REGULATORS WILL BE INSTALLED REDUCING 2 LB. PRESSURE TO 4 OZ.7. PROVIDE 1 SQ. FT. OF CRAWL SPACE VENTILATION FOR EVERY 150 SQ. FT. OF CRAWL SPACE (TYP.)8. SECURE TOP & BOTTOM 1/3 OF WATER HEATER W/APPROVED SEISMIC STRAPS AND INSTALL EXPANSION TANK PER LOCAL REQUIREMENT 9. PROVIDE COMBUSTION AIR FROM OUTSIDE TO FURNACE & WATER HEATER 10.HOT WATER LINES TO HAVE 1/2" FOAM INSULATION UP TO FIREPLACE
FU
R
N
.
AB
V
.
W.H
.
AB
V
.
3'-6" GASLINE
10'
-
6
"
G
A
S
L
I
N
E
39'-4" GASLINE
GA
S ME
T
E
R
BL
O
C
K
O
U
T
FO
R
D
O
O
R
RE
C
E
S
S
F
O
U
N
D
A
T
I
O
N
WA
L
L
&
P
O
U
R
S
L
A
B
T
H
R
U
SLOPE 1/8"/FT.
SLOPE
1/8"/FT.
SL
O
P
E
1/8
"
/
F
T
.
37'
-
0
"
G
A
S
L
I
N
E
1'-
9
"
3'-0
"
25
'
-
9
"
14'-2"
45
'
-
4
"
30
'
-
6
"
90
'
-
0
"
31'-10"11'-6"12'-0"
55'-4"
6'-
8
"
9'-
0
"
2'-
0
"
9'-
0
"
3'-
0
"
14'-2"
40'
-
1
0
"
5'-
4
"
29
'
-
8
"
90
'
-
0
"
3'-10"19'-1 1/2"18'-8"13'-8 1/2"55'-4"
19
'
-
2
3
/
4
"
19
'
-
1
1
1
/
4
"
12
'
-
6
"
12
'
-
9
1
/
4
"
19
'
-
2
3
/
4
"
18'-11 1/4"17'-4 1/2"13'-6 1/4"
4'-
0
"
6'-8"
* 10" CMU FOUNDATION U.N.O.
6" CMU
6"
C
M
U
project:revisions:Project number Date Drawn by Engineered by7707 SOUTH MAIN STREET MIDVALE, UT 84047 801.285.8885CRAIG WALL DESIGN EACH SUB-CONTRACTOR SHALL CHECK AND UNDERSTAND ALL DIMENSIONS, NOTES AND OTHER ASPECTS OF THIS PROJECT APPLICABLE TO THEIR TRADE AND AFFECTING OTHER TRADES PRIOR TO AND DURING CONSTRUCTION.NOTIFY DESIGNER OR ENGINEER IN WRITING OF ANY DISCREPANCIES OR CHANGES ON THE DRAWINGS BEFORE PROCEEDING WITH ANY WORK.EACH SUB-CONTRACTOR SHALL COORDINATE WORK WITH OTHER TRADE THROUGH THE GENERAL CONTRACTOR.THE DESIGNER WILL NOT ASSUME RESPONSIBILITY FOR ANY MISUSE OR MISREADING OF THESE PLANS. WHERE INFORMATION IS AVAILABLE BUT UNCLEAR, THE PERSON USING THESE PLANS IS RESPONSIBLE FOR CLARIFYING ANY QUESTIONS ACCORDING TO THE CONDITIONS STATED ABOVE.A2.0MARCH 26, 2021SOMMER RESIDENCE LOT 4 BLOCK 1 PINE BROOK ESTATES REXBURG, ID CWD N/A FOOTING & FOUNDATION PLAN
LIV
I
N
G
R
O
O
M
9'-
0
"
C
L
G
.
KIT
C
H
E
N
9'-
0
"
C
L
G
.
BE
D
R
O
O
M
9'-
0
"
C
L
G
.
BE
D
R
O
O
M
9'-
0
"
C
L
G
.
MA
S
T
E
R
B
E
D
R
O
O
M
9'-
0
"
C
L
G
.
FA
M
I
L
Y
R
O
O
M
11
'
-
0
"
C
L
G
.
DIN
I
N
G
9'-
0
"
C
L
G
.
GA
R
A
G
E
21
7
9
S
Q
.
F
T
.
SC
A
L
E
1
/
4
"
=
1
'
-
0
"
MA
I
N
F
L
O
O
R
P
L
A
N
91
6
S
Q
.
F
T
.
(
G
A
R
A
G
E
)
A
A5.1
AA5.1
BENCH
W/D
BL
O
C
K
O
U
T
C
O
N
C
.
& C
M
U
FO
U
N
D
A
T
I
O
N
FO
R
H
V
A
C
RE
F
DB
L
OV
E
N
TU
B
SH
W
R
SH
W
R
+18" RAISED PLATFORM
CR
A
W
L
SP
A
C
E
AC
C
E
S
S
MA
S
T
E
R
BA
T
H
9'-
0
"
C
L
G
.
W.I
.
C
.
PA
N
T
R
Y
LA
U
N
D
R
Y
ST
O
R
A
G
E
ME
C
H
.
CO
V
E
R
E
D
PO
R
C
H
BA
T
H
COVERED PATIO
2'-
4
"
3'-
0
"
2'-
4
"
2'-
4
"
5'-0"
3'-
0
"
2'-
6
"
2'-
4
"
2'-
6
"
9'-
0
"
x
8
'
-
0
"
OV
E
R
H
E
A
D
3'-
0
"
x
6
'
-
8
"
T
E
M
P
.
6'-0"x6'-8" TEMP.
9'-
0
"
x
8
'
-
0
"
OV
E
R
H
E
A
D
5'-
0
"
(3) 3'-0"x5'-0" S.H.
(3) 3'-0"x5'-0" S.H.
3'-0"x5'-0" S.H.
3'-0"x5'-0" S.H.
3'-0"x5'-0" S.H.
4'-
0
"
2'-
8
"
6'-
0
"
3'-0"x5'-0" S.H. w/3'-0"x2'-0" TRANSOM 3'-0"x5'-0" S.H. w/3'-0"x2'-0" TRANSOM
3'-
0
"
5'-
0
"
(2
)
3
'
-
0
"
x
5
'
-
0
"
S
.
H
.
(2
)
2
'
-
0
"
x
5
'
-
0
"
S
.
H
.
TE
M
P
.
(2
)
3
'
-
0
"
x
3
'
-
0
"
S
.
H
.
TE
M
P
.
3'-0"x5'-0" S.H.
FU
R
N
.
W.H
.
2'-
0
"
TE
M
P
.
2'-
0
"
TE
M
P
.
COOKTOP
DB
'
L
S
I
N
K
w/
D
I
S
P
.
22"
X
3
0
"
ATT
I
C
AC
C
E
S
S
SLOPE 1/8"/FT.
SLOPE
1/8"/FT.
SL
O
P
E
1/8
"
/
F
T
.
D.W
.
FIREPLACE
6"
C
M
U
w
/
B
R
I
C
K
2x
6
w
/
B
R
I
C
K
6" CMU w/ BRICK 6" CMU w/ BRICK
6"
C
M
U
w
/
B
R
I
C
K
2x
6
w
/
B
R
I
C
K
2x6 w/ BRICK 2x6 w/ BRICK
2x6
w
/
B
R
I
C
K
6"
C
M
U
6"
C
M
U
6" CMU
2x6
2x6
EN
T
R
Y
9'-
0
"
C
L
G
.
11' CLG.
9' CLG.
2'-
1
1
"
26
'
-
1
1
"
9'-
5
"
3'-
8
"
6'-
3
1
/
4
"
5'-
9
3
/
4
"
5'-
5
1
/
2
"
12
'
-
1
"
13
'
-
1
"
14
'
-
6
1
/
2
"
2'-0"11'-2 1/2"1'-6"
45
'
-
2
"
29
'
-
1
0
"
89
'
-
8
1
/
2
"
5'-8" 5'-6" 5'-6" 7'-3"7'-3" 2'-5" 2'-0 1/2" 2'-7" 2'-3 1/2" 7'-0"7'-0"
4'-5 1/2" 4'-10 1/2"14'-0"
16'-8"14'-6"23'-4"
54'-6"
2'-0
"
3
'
-
1
0
1
/
2
"
9'-10 1/2" 2'-0"
9'-9
"
15
'
-
9
"
7'-
2
"
9'-
0
"
2'-0
"
9'-0
"
4'-8
"
25
'
-
6
"
14
'
-
4
"
5'-
4
"
31
'
-
1
0
"
2'-0"11'-2 1/2"1'-6"
39
'
-
1
0
"
37
'
-
2
"
91
'
-
8
1
/
2
"
9'-9 1/2"9'-4" 2'-10 1/2" 2'-7 1/2"2'-7 1/2" 2'-7" 6'-11"7'-1"19'-1 1/2"5'-6"5'-2 1/2"14'-0"24'-7 1/2"6'-8"19'-2 1/2"4'-0"18'-7"2'-0"14'-9"2'-0"13'-2"54'-6"
6'-9" 4'-3" 3'-3 1/2" 4'-4 1/2" 5'-9 1/2" 7'-0" 4'-7" 2'-3 1/2" 3'-1 1/2" 3'-0" 3'-1 1/2" 2'-0"
6'-6" 4'-6" 11" 2'-4 1/2"
4 1/2"
18
'
-
7
"
2'-1
1
1
/
2
"
3'-1
"
2'-
4
"
11
'
-
7
"
5'-
9
1
/
2
"
6'-
3
1
/
2
"
3'-
3
1
/
2
"
3'-
6
"
4'-
0
1
/
2
"
8'-
0
1
/
2
"
5'-
5
1
/
2
"
11'
-
6
1
/
2
"
8'-
6
"
3'-
0
"
2'-
0
"
4'-
6
"
6'-0"12'-0"5'-6" 6'-8"
1'-
0
1
/
2
"
3'-
0
"
6 1
/
2
"
8'-0
"
2
'
-
0
"
1'-
7
1
/
2
"
2'-
6
"
8"
4'-0
"
8"
2'-
6
"
1'-7
1
/
2
"
VE
N
T
D
R
Y
E
R
TO
O
U
T
S
I
D
E
20
M
I
N
.
w
/
CLO
S
E
R
ELE
C
.
PA
N
E
L
4'-
0
"
6'-2"
NOTES:1. EXTERIOR WALL FRAMING TO BE 2X6,INTERIOR WALL FRAMING TO BE 2X4 U.N.O.2. PROVIDE 20 MIN. RATED DOOR w/ CLOSER @ DOOR BETWEEN GARAGE AND HOUSE.3. ALL CONCRETE STEPS TO HAVE A MIN. RUN OF 11"4. PROVIDE 36" LANDING w/ 1 1/2" MAX. DROP BETWEEN THRESHOLD AND LANDING (7 3/4" MAX.DROP IF DOOR SWINGS IN).-IRC 2018, R311.3 5. DRYER EXHAUST NOTE:THE MAX. LENGTH OF A CLOTHES DRYER EXHAUST DUCT SHALL NOT EXCEED 25 FEET FROM THE DRYER LOCATION TO THE WALL OR ROOF TERMINATION. THE MAX. LENGTH OF THE DUCT SHALL BE REDUCED 2.5 FEET FOR EACH 45-DEGREE BEND AND 5 FEET FOR EACH 90-DEGREE BEND. THE MAX. LENGTH OF THE EXHAUST DUCT DOES NOT INCLUDE THE TRANSITION DUCT.-IRC 2018, M1502.4.5 6. PROVIDE INSULATION ON WATER LINES ON EXTERIOR WALLS TO PREVENT FREEZING 7. SECURE TOP & BOTTOM 1/3 OF WATER HEATER W/APPROVED SEISMIC STRAPS AND INSTALL EXPANSION TANK PER LOCAL REQUIREMENT 8. PROVIDE COMBUSTION AIR FROM OUTSIDE TO FURNACE & WATER HEATER 9. HOT WATER LINES TO HAVE 1/2" FOAM INSULATION 10.PROVIDE SAFE PAN BENEATH FURNACE project:revisions:Project number Date Drawn by Engineered by7707 SOUTH MAIN STREET MIDVALE, UT 84047 801.285.8885CRAIG WALL DESIGN EACH SUB-CONTRACTOR SHALL CHECK AND UNDERSTAND ALL DIMENSIONS, NOTES AND OTHER ASPECTS OF THIS PROJECT APPLICABLE TO THEIR TRADE AND AFFECTING OTHER TRADES PRIOR TO AND DURING CONSTRUCTION.NOTIFY DESIGNER OR ENGINEER IN WRITING OF ANY DISCREPANCIES OR CHANGES ON THE DRAWINGS BEFORE PROCEEDING WITH ANY WORK.EACH SUB-CONTRACTOR SHALL COORDINATE WORK WITH OTHER TRADE THROUGH THE GENERAL CONTRACTOR.THE DESIGNER WILL NOT ASSUME RESPONSIBILITY FOR ANY MISUSE OR MISREADING OF THESE PLANS. WHERE INFORMATION IS AVAILABLE BUT UNCLEAR, THE PERSON USING THESE PLANS IS RESPONSIBLE FOR CLARIFYING ANY QUESTIONS ACCORDING TO THE CONDITIONS STATED ABOVE.A3.0MARCH 26, 2021SOMMER RESIDENCE LOT 4 BLOCK 1 PINE BROOK ESTATES REXBURG, ID CWD N/A MAIN FLOOR PLAN
A
A5.1
AA5.1
SC
A
L
E
1
/
4
"
=
1
'
-
0
"
MA
I
N
F
L
O
O
R
F
R
A
M
I
N
G
P
L
A
N
11
7
/
8
"
T
J
I
/
2
1
0
@
1
6
"
O
.
C
.
project:revisions:Project number Date Drawn by Engineered by7707 SOUTH MAIN STREET MIDVALE, UT 84047 801.285.8885CRAIG WALL DESIGN EACH SUB-CONTRACTOR SHALL CHECK AND UNDERSTAND ALL DIMENSIONS, NOTES AND OTHER ASPECTS OF THIS PROJECT APPLICABLE TO THEIR TRADE AND AFFECTING OTHER TRADES PRIOR TO AND DURING CONSTRUCTION.NOTIFY DESIGNER OR ENGINEER IN WRITING OF ANY DISCREPANCIES OR CHANGES ON THE DRAWINGS BEFORE PROCEEDING WITH ANY WORK.EACH SUB-CONTRACTOR SHALL COORDINATE WORK WITH OTHER TRADE THROUGH THE GENERAL CONTRACTOR.THE DESIGNER WILL NOT ASSUME RESPONSIBILITY FOR ANY MISUSE OR MISREADING OF THESE PLANS. WHERE INFORMATION IS AVAILABLE BUT UNCLEAR, THE PERSON USING THESE PLANS IS RESPONSIBLE FOR CLARIFYING ANY QUESTIONS ACCORDING TO THE CONDITIONS STATED ABOVE.A4.0MARCH 26, 2021SOMMER RESIDENCE LOT 4 BLOCK 1 PINE BROOK ESTATES REXBURG, ID CWD N/A MAIN FLOOR FRAMING PLAN
A
A5.1
AA5.1(11' CLG.)PRE-MANUFACTURED TRUSSES @ 24" O.C.
GIRDER TRUSS
SCALE 1/4"=1'-0"ROOF FRAMING PLAN
GIRDER TRUSS
OVER-BUILD
GIRDER
GIR
D
E
R
GIR
D
E
R
OVERBUILD
OVERBUILD
GIR
D
E
R
GIR
D
E
R
project:revisions:Project number Date Drawn by Engineered by7707 SOUTH MAIN STREET MIDVALE, UT 84047 801.285.8885CRAIG WALL DESIGN EACH SUB-CONTRACTOR SHALL CHECK AND UNDERSTAND ALL DIMENSIONS, NOTES AND OTHER ASPECTS OF THIS PROJECT APPLICABLE TO THEIR TRADE AND AFFECTING OTHER TRADES PRIOR TO AND DURING CONSTRUCTION.NOTIFY DESIGNER OR ENGINEER IN WRITING OF ANY DISCREPANCIES OR CHANGES ON THE DRAWINGS BEFORE PROCEEDING WITH ANY WORK.EACH SUB-CONTRACTOR SHALL COORDINATE WORK WITH OTHER TRADE THROUGH THE GENERAL CONTRACTOR.THE DESIGNER WILL NOT ASSUME RESPONSIBILITY FOR ANY MISUSE OR MISREADING OF THESE PLANS. WHERE INFORMATION IS AVAILABLE BUT UNCLEAR, THE PERSON USING THESE PLANS IS RESPONSIBLE FOR CLARIFYING ANY QUESTIONS ACCORDING TO THE CONDITIONS STATED ABOVE.A4.1MARCH 26, 2021SOMMER RESIDENCE LOT 4 BLOCK 1 PINE BROOK ESTATES REXBURG, ID CWD N/A ROOF FRAMING PLAN
AN
Y
E
N
G
I
N
E
E
R
I
N
G
N
O
T
E
S
A
N
D
SP
E
C
I
F
I
C
A
T
I
O
N
S
S
U
P
E
R
S
E
D
E
TH
E
S
E
N
O
T
E
S
A
N
D
C
A
L
L
-
O
U
T
S
NO
T
E
:
GENERAL NOTES:1 . CONSTRUCTION SHALL BE IN ACCORDANCE WITH ALL ADOP TED CODES AND REGULATIONS SET FORTH BY THE JURISDICTION IN WHICH CONSTRUCTION TAKES PLACE.2. PROVIDE ATTIC ACCESS CLEAR OPENING OF 22"X30". AC CESS SHALL NOT BE LOCATED ABOVE A CLOSET SHELF AND SHALL HAVE 30" MIN. HEAD R OOM.3. CEMENT, FIBER-CEMENT, OR GLASS MAT GYPSUM BACKERS ARE REQUIRED AS A BACKER FOR WALL TILE IN TUB & SHOWER AREAS & WALL PANELS I N SHOWER AREAS. R702.4.2 4. INSTALL 5/8" TYPE "X" GYP. ON ALL WALLS, CEILIN G, BEAMS AND SUPPORTS IN GARAGE FOR FIRE PROTECTION BETWEEN HOUSE AND GARAGE. (INSTALL (2) LAYERS OF TYPE 'X' GYPSUM BOARD PERPENDICULAR TO CEILING FRAMING FOR GARAGE CEILING S BENEATH HABITABLE ROOMS.OTHERWISE EITHER DIRECTION WILL SUFFICE.). EACH SHE ET TO BE NAILED 4" O.C. AT EDGES AND 6"O.C. IN FIELD.5. ATTIC VENTILATION AS FOLLOWS: 1 SQ. FT./150 SQ. FT. OF ATTIC AREA.6. ALL FOOTINGS SHALL BE PLACED 12" BELOW UNDISTUR BED EARTH AND A MIN. OF 30"BELOW FINISHED GRADE OR AS NOTED ON PLAN. TOP OF F OUNDATION TO BE A MIN. 6" ABOVE FINISHED GRADE. FINISHED GRADE TO HAVE A MIN. 6" S LOPE AWAY FROM BUILDING FOR FIRST 10 FEET. ALL DRAINAGE FROM LOT TO DRAIN INTO APPROVED DRAINING SYSTEM.7.
M
E
T
A
L
F
L
A
S
H
I
N
G
R
E
Q
'
D
F
O
R
M
A
S
O
N
R
Y
V
E
N
E
E
R
R
E
Q
'
D
F
R
O
M FOUNDATION UP THE FIRST THREE COURSES, & 3/16" WEEP HOLES 33" O.C. FLASHIN G TO EXTEND BEYOND FOUNDATION EDGE 1/2".WINDOWS :1 . BEDROOM WINDOWS SHALL HAVE A MIN. CLEAR OPENING O F 5.7 SQ. FT. WITH A MIN. NET CLEAR OPENING WIDTH OF 20" (FOR A TALL WINDOW) AND A MIN. NET CLEAR OPENING HEIGHT OF 24" (FOR A WIDE WINDOW) AND A FINISHED SILL HEIG HT NOT TO EXCEED 44" ABOVE THE FINISHED FLOOR.2. GLASS USED IN TUB OR SHOWER ENCLOSURES TO BE FU LLY TEMPERED.3. TEMPERED GLASS SHALL BE USED IN ALL GLASS DOORS , GLASS IN DOORS, WINDOWS OVER BATHTUBS, WINDOWS WITHIN 18" OF THE FLOOR, GLAZING IN GUARD RAILINGS, AND WINDOWS WITHIN 24" OF ANY DOOR.4.
P
R
O
V
I
D
E
9
"
F
L
A
S
H
I
N
G
A
R
O
U
N
D
A
L
L
W
I
N
D
O
W
S
&
D
O
O
R
S
W
I
T
H
S
ILL PLATE FLASHING.5.
F
L
A
S
H
&
C
A
U
L
K
A
R
O
U
N
D
A
L
L
E
X
T
E
R
I
O
R
W
I
N
D
O
W
S
&
D
O
O
R
S
P
E
R
MANUFACTURERS RECOMMENDATIONS.MECHANICAL:1 .COMBUSTION AIR TO BE TAKEN FROM OUTSIDE.2. COMBUSTION AIR DUCTS TO BE LOCATED WITHIN THE UPP ER 12" OF CEILING AND WITHIN 12" OF THE FLOOR.3. DUCTS USED FOR COMBUSTION TO REMAIN SEPARATE FRO M THE ENCLOSURE TO THE OUTSIDE AIR SOURCE.4. FURNACES IN A CLOSET SHALL HAVE A MIN. 3" CLEAR WORK ING SPACE ON SIDES, BACK AND TOP.5. VENTS SHALL TERMINATE 4' BELOW, OR 4' HORIZONTALLY AND AT LEAST 1' ABOVE A DOOR,OPERABLE WINDOW, OR GRAVITY AIR INLET INTO A BUILDIN G.6. FLUE AND EXHAUST FAN VENTS SHALL BE AT LEAST 3' AB OVE AN OUTSIDE AIR INLET LOCATED WITHIN 10' AND AT LEAST 4' FROM PROPERTY LINE.7. MIN. 30" CLEARANCE REQ'D ABOVE RANGE TOP TO COMBU STIBLES.8. EXHAUST FANS PROVIDING 5 AIR CHANGES PER HOUR T O BE INSTALLED IN BATHROOMS AND LAUNDRY ROOM WITHOUT AN OPERABLE WINDOW.9. RESIDENTIAL HEATING DUCT JOINTS TO BE FASTENED WITH AT LEAST 3 SHEET METAL SCREWS EVENLY SPACED. SUPPORT DUCTS WITH APPROVED META SUPPORTS.10. PROVIDE COMBUSTION AIR TO LAUNDRY AREA.PLUMBING:1 . PROVIDE SEISMIC STRAPS ON WATER HEATER.2. ALL TOILETS TO BE LOW-FLUSH TYPE. MAX. 1.6 GAL. PER FLUSH.3. MAX. FLOW RATE FOR SHOWER HEADS TO BE 2.5 GAL. PER MINUTE.4. PROVIDE OUTSIDE COMBUSTION AIR FOR WATER HEATER .5. PLUMBING VENTS SHALL BE AT LEAST 3' ABOVE OR 10 ' AWAY FROM ALL OUTSIDE AIR INTAKE OPENINGS.6. FLAG POLING OF PLUMBING VENTS IS PROHIBITED EXC EPT WHERE ROOM IS OCCUPIED.7. ALL HOSE BIBS TO BE FREEZE LESS AND HAVE BACK F LOW PREVENTOR.8. PLUMBING PENETRATIONS THROUGH GARAGE FIRE WALL MUST BE WITH METAL PIPING.9. NO SLIP JOINT PLUMBING CONNECTIONS ALLOWED IN C ONCEALED CONSTRUCTION AREAS.(BATH TUBS).10. INDIVIDUALLY INSULATE WALL PLUMBING, WATER, DRAIN LINES IN AREAS SUBJECT TO FREEZING. EXTERIOR WALLS, ATTICS, CRAWL SPACES, GA RAGES.ELECTRICAL:1 . SMOKE DETECTORS AT EACH BEDROOM, AT HALLWAYS LEAD ING TO BEDROOMS, AT EVERY FLOOR LEVEL INCLUDING BASEMENTS, AT THE TOP OF EAC H STAIRWAY ON FLOORS WITHOUT BEDROOMS, AND IN ROOMS SERVING BEDROOMS WHERE THE CEILING HEIGHT OF THE ROOM IS 24" OR GREATER IN HEIGHT THAN THE BEDROOM SERVE D FROM SUCH ROOM. SMOKE DETECTORS SHALL BE HARD WIRED TOGETHER IN SERIES W/ BATTERY BACKUP.2. BATHROOM RECEPTACLE OUTLETS SHALL BE SUPPLIED B Y DEDICATED 20 AMP BRANCH CIRCUIT W/ NO OTHER OUTLETS.3. ELECTRICAL RECEPTACLE OUTLETS SHALL BE SUPPLIED WITHIN 25' OF HVAC EQUIPMENT (IRC -
E
3
8
0
1
.
1
1
)
.
4. LIGHTS IN CLOSETS SHALL CONFORM TO CLEARANCES S PECIFIED PER CODE 5. TEMP. WIRING SHALL CONFORM TO APPLICABLE CODE.6. ANY LIGHT FIXTURES OVER TUBS AND SHOWERS SHALL COMPLY WITH CURRENT CODE REQUIREMENTS.7. ALL CEILING FANS TO HAVE FAN RATED BOX.8. ALL KITCHEN SURFACE OUTLETS, BATH OUTLETS, GARA GE OUTLETS, OUTLETS OUTDOORS WITH DIRECT GRADE LEVEL ACCESS INCLUDING DECKS, BA LCONIES, UNDER EAVES, CRAWL SPACES, AND IN UNFINISHED BASEMENTS TO BE GFI.FRAMING:1 . SOLID BLOCKING BETWEEN JOISTS, RAFTERS, AND TRUSS ES OVER BEARING WALLS.2. PROVIDE DOUBLE JOISTS UNDER BEARING WALL LOCATI ONS WHERE SUCH WALLS ARE PARALLEL WITH JOISTS.
TY
P
.
W
A
L
L
S
E
C
T
I
O
N
TO
P
O
F
F
O
O
T
I
N
G
TO
P
O
F
F
O
U
N
D
A
T
I
O
N
W
A
L
L
MA
I
N
F
I
N
I
S
H
F
L
O
O
R
TO
P
P
L
A
T
E
P
E
R
P
L
A
N
P
E
R
P
L
A
N
PE
R
PL
A
N
PE
R
P
L
A
N
SC
A
L
E
3
/
4
"
=
1
'
-
0
"
2X
T
R
E
A
T
E
D
P
L
A
T
E
W
/
A
N
C
H
O
R
BO
L
T
S
S
P
A
C
E
D
P
E
R
E
N
G
I
N
E
E
R
I
N
G
CA
L
C
U
L
A
T
I
O
N
S
.
3/4
"
T
&
G
W
A
F
E
R
W
O
O
D
O
V
E
R
FLO
O
R
J
O
I
S
T
S
,
G
L
U
E
&
N
A
I
L
.
S
E
E
FLO
O
R
F
R
A
M
I
N
G
P
L
A
N
F
O
R
J
O
I
S
T
SIZ
E
&
S
P
A
C
I
N
G
8"
C
O
N
C
.
F
O
U
N
D
A
T
I
O
N
W
A
L
L
w
/
AP
P
R
O
V
E
D
W
A
T
E
R
R
E
S
I
S
T
A
N
T
EM
U
L
S
I
O
N
FO
O
T
I
N
G
P
E
R
S
C
H
E
D
U
L
E
4"
C
O
N
C
.
S
L
A
B
O
V
E
R
AP
P
R
O
V
E
D
S
O
I
L
AL
U
M
.
S
O
F
F
I
T
(
V
E
N
T
E
D
)
ST
U
C
C
O
S
Y
S
T
E
M
O
R
S
I
D
I
N
G
O
V
E
R
MIN
.
(
2
)
L
A
Y
E
R
S
O
F
N
O
.
1
5
AS
P
H
A
L
T
F
E
L
T
O
V
E
R
WA
F
E
R
W
O
O
D
O
V
E
R
2
x
S
T
U
D
S
SP
A
C
E
D
P
E
R
E
N
G
I
N
E
E
R
S
C
A
L
C
S
.
w/ I
N
S
U
L
.
NO
T
E
:
EX
T
E
R
I
O
R
W
A
L
L
F
I
N
I
S
H
E
S
M
U
S
T
BE
L
I
S
T
E
D
,
L
A
B
E
L
E
D
,
A
N
D
IN
S
T
A
L
L
E
D
A
S
P
E
R
MA
N
U
F
A
C
T
U
R
E
R
'
S
I
N
S
T
A
L
L
A
T
I
O
N
IN
S
T
R
U
C
T
I
O
N
G
U
I
D
E
S
.
RIM
J
O
I
S
T
W
/
B
L
O
C
K
I
N
G
SIM
P
S
O
N
H
1
A
N
C
H
O
R
EV
E
R
Y
T
R
U
S
S
2X
F
A
S
C
I
A
B
D
.
w
/
AL
U
M
I
N
U
M
D
R
I
P
E
D
G
E
SO
L
I
D
2
X
B
L
O
C
K
I
N
G
IN
S
T
A
L
L
I
C
E
&
W
A
T
E
R
S
H
I
E
L
D
P
E
R
L
O
C
A
L
CO
D
E
-
I
C
E
&
W
A
T
E
R
S
H
I
E
L
D
M
U
S
T
E
X
T
E
N
D
FR
O
M
T
H
E
E
D
G
E
O
F
T
H
E
E
A
V
E
S
T
O
A
P
O
I
N
T
NO
T
L
E
S
S
T
H
A
N
2
4
"
I
N
S
I
D
E
T
H
E
E
X
T
E
R
I
O
R
WA
L
L
L
I
N
E
AS
P
H
A
L
T
S
H
I
N
G
L
E
S
O
V
E
R
(
1
)
LA
Y
E
R
O
F
N
O
.
1
5
F
E
L
T
O
V
E
R
WA
F
E
R
W
O
O
D
(
G
A
P
1
/
8
"
U
S
E
H-C
L
I
P
S
)
O
V
E
R
T
R
U
S
S
E
S
IN
S
U
L
.
B
A
F
F
L
E
R-3
8
I
N
S
U
L
.
MIN
.
S
E
E
RE
S
C
H
E
C
K
MID
-
H
E
I
G
H
T
B
L
O
C
K
I
N
G
@
BE
A
R
I
N
G
W
A
L
L
S
R-1
9
I
N
S
U
L
A
T
I
O
N
M
I
N
.
SE
E
R
E
S
C
H
E
C
K
R-1
9
I
N
S
U
L
A
T
I
O
N
M
I
N
.
SE
E
R
E
S
C
H
E
C
K
HO
U
S
E
D
R
A
I
N
A
G
E
F
I
N
A
L
G
R
A
D
E
S
TO
B
E
M
I
N
.
6
"
O
F
F
A
L
L
F
O
R
F
I
R
S
T
10
'
F
R
O
M
H
O
M
E
.
MIN
.
S
T
A
I
R
R
E
Q
U
I
R
E
M
E
N
T
S
HA
N
D
R
A
I
L
:
1
1
/
4
"
-
2
5
/
8
"
D
I
A
.
C
R
O
S
S
SE
C
T
I
O
N
A
L
D
I
M
E
N
S
I
O
N
R
E
T
U
R
N
E
N
D
S
TO
W
A
L
L
GU
A
R
D
R
A
I
L
T
O
B
E
M
I
N
I
M
U
M
H
E
I
G
H
T
O
F
3
6
"
A
N
D
H
A
V
E
N
O
N
ET
OP
E
N
I
N
G
S
E
X
C
E
E
D
I
N
G
4
"
O
N
V
E
R
T
I
C
A
L
B
A
L
U
S
T
E
R
S
SC
A
L
E
1
/
2
"
=
1
'
-
0
"
(3
)
2
"
X
1
2
"
P
A
R
A
L
L
A
M
S
T
R
I
N
G
E
R
S
1/2
"
T
Y
P
E
"
X
"
G
Y
P
.
2"
X
4
"
R
E
D
W
O
O
D
O
R
T
R
E
A
T
E
D
P
L
A
T
E
F.F
.
P
E
R
P
L
A
N
JO
I
S
T
P
E
R
P
L
A
N
10
"MIN
.
7
3
/
4
"
M
A
X
.
6
'
-
8
"
M
I
N
.
H
E
A
D
R
O
O
M
3
4
"
3
8
"
M
I
N
.
M
A
X
.
3/4
"
M
I
N
.
T
O
1 1
/
4
"
M
A
X
.
NO
S
I
N
G
:
WIN
D
O
W
W
E
L
L
R
E
Q
U
I
R
E
M
E
N
T
S
36
"
M
I
N
.
36" MIN.
NO
T
E
S
:
1 .
W
I
N
D
O
W
W
E
L
L
R
E
Q
U
I
R
E
D
F
O
R
E
S
C
A
P
E
A
N
D
R
E
S
C
U
E
W
I
N
D
O
WS
W
I
T
H
FIN
I
S
H
E
D
S
I
L
L
H
E
I
G
H
T
B
E
L
O
W
T
H
E
A
D
J
A
C
E
N
T
G
R
O
U
N
D
E
L
E
V
AT
I
O
N
.
2. A
L
L
W
I
N
D
O
W
W
E
L
L
S
W
I
T
H
A
V
E
R
T
I
C
A
L
D
E
P
T
H
O
F
M
O
R
E
TH
A
N
4
4
"
S
H
A
L
L
B
E
EQ
U
I
P
P
E
D
W
I
T
H
A
P
E
R
M
A
N
E
N
T
L
Y
A
F
F
I
X
E
D
L
A
D
D
E
R
.
A
L
L
L
A
D
DE
R
S
M
U
S
T
H
A
V
E
A
14
M
I
N
.
W
I
D
T
H
,
1
4
"
M
A
X
.
S
P
A
C
E
B
E
T
W
E
E
N
R
U
N
G
S
A
N
D
A
6
" M
I
N
.
T
O
E
S
P
A
C
E
.
3. A
N
Y
G
R
A
T
E
S
,
B
A
R
S
,
G
R
I
L
L
S
,
D
O
M
E
S
O
R
S
I
M
I
L
A
R
D
E
V
I
CE
S
O
N
W
I
N
D
O
W
W
E
L
L
S
RE
Q
U
I
R
E
A
N
A
P
P
R
O
V
E
D
R
E
L
E
A
S
E
M
E
C
H
A
N
I
S
M
.
4. E
G
R
E
S
S
/
R
E
S
C
U
E
W
I
N
D
O
W
S
A
R
E
R
E
Q
U
I
R
E
D
T
O
B
E
5
.
7
S
Q
.F
T
.
C
L
E
A
R
O
P
E
N
WIT
H
A
M
I
N
.
N
E
T
C
L
E
A
R
O
P
E
N
I
N
G
W
I
D
T
H
O
F
2
0
"
(
F
O
R
A
T
AL
L
W
I
N
D
O
W
)
,
A
N
D
A
5. E
G
R
E
S
S
/
R
E
S
C
U
E
W
I
N
D
O
W
S
A
R
E
R
E
Q
U
I
R
E
D
I
N
E
V
E
R
Y
B
E
D
RO
O
M
A
N
D
A
T
LE
A
S
T
O
N
E
I
N
A
B
A
S
E
M
E
N
T
.
V
E
R
I
F
Y
W
I
N
D
O
W
S
M
E
E
T
E
G
R
E
S
S A
S
I
N
D
I
V
I
D
U
A
L
MA
N
U
F
A
C
T
U
R
E
R
S
M
A
Y
V
A
R
Y
I
N
N
E
T
C
L
E
A
R
O
P
E
N
I
N
G
.
LA
D
D
E
R
-
W
H
E
N
RE
Q
U
I
R
E
D
9 S
Q
.
F
T
.
N
E
T
C
L
E
A
R
DIM
E
N
S
I
O
N
(
3
6
"
SM
A
L
L
E
S
T
D
I
R
.
)
WH
E
N
W
I
N
D
O
W
I
S
FU
L
L
Y
O
P
E
N
SC
A
L
E
1
/
2
"
=
1
'
-
0
"
AP
P
R
O
V
E
D
W
I
N
D
O
W
WE
L
L
W
A
L
L
DE
T
A
I
L
-
4
"
L
E
D
G
E
@
P
O
R
C
H
C
A
P
4"
6
"
M
A
X
.
SC
A
L
E
1
/
2
"
=
1
'
-
0
"
ME
T
A
L
F
L
A
S
H
I
N
G
ST
O
R
A
G
E
O
R
CO
M
P
A
C
T
E
D
G
R
A
D
E
PE
R
P
L
A
N
RE
I
N
F
O
R
C
I
N
G
P
E
R
EN
G
I
N
E
E
R
S
S
P
E
C
S
.
6"
M
I
N
.
S
L
A
B
SL
O
P
E
T
O
D
R
A
I
N
FD
N
.
W
A
L
L
PE
R
P
L
A
N
MA
I
N
T
A
I
N
4
"
L
E
D
G
E
F
O
R
PO
R
C
H
C
A
P
(
T
H
I
C
K
E
N
W
A
L
L
AS
R
E
Q
'
D
)
DE
T
A
I
L
-
T
Y
P
.
C
O
N
C
.
P
E
D
E
S
T
A
L
FT
G
.
S
I
Z
E
& R
E
I
N
F
.
P
E
R
S
C
H
E
D
.
A
S
R
E
Q
'
D
F
O
R
U
N
D
I
S
T
U
R
B
E
D
B
E
A
R
I
N
G
O
R
F
R
O
S
T
D
E
P
T
H
W
H
I
C
H
E
V
E
R
I
S
G
R
E
A
T
E
R
SO
I
L
B
R
G
.
EX
T
E
R
I
O
R
HA
R
D
S
C
A
P
E
#4
D
O
W
E
L
S
-
E
X
T
E
N
D
FU
L
L
H
E
I
G
H
T
O
F
PE
D
E
S
T
A
L
#3
T
I
E
S
@
1
0
"
O
.
C
.
UN
D
I
S
T
U
R
B
E
D
1/2
"
E
X
P
A
N
S
I
O
N
M
A
T
'
L
1"
C
H
A
M
F
E
R
SC
A
L
E
1
"
=
1
'
-
0
"
PE
R
PLA
N
CO
L
U
M
N
P
E
R
P
L
A
N
2"
M
I
N
.
SL
O
P
E
1
.
5
%
F
R
O
M
E
X
T
E
R
I
O
R
W
A
L
L
OF
H
O
U
S
E
T
O
F
R
O
N
T
O
F
P
O
R
C
H
"B
"
D
E
C
K
B
A
S
E
.
P
R
O
V
I
D
E
A
MIN
2
"
O
V
E
R
A
G
E
A
T
F
O
U
N
D
A
T
I
O
N
W
A
L
L
S
PR
O
V
I
D
E
A
1
"
O
V
E
R
H
A
N
G
A
T
P
O
R
C
H
CA
P
O
V
E
R
F
O
U
N
D
A
T
I
O
N
W
A
L
L
SE
E
E
N
G
I
N
E
E
R
I
N
G
F
O
R
P
O
R
C
H
C
A
P
RE
-
F
O
R
C
I
N
G
PR
O
V
I
D
E
A
M
I
N
.
O
F
1
2
"
I
C
E
A
N
D
WA
T
E
R
S
H
I
E
L
D
O
V
E
R
W
E
A
T
H
E
R
BA
R
R
I
E
R
B
E
T
W
E
E
N
P
O
R
C
H
C
A
P
AN
D
E
X
P
O
S
E
D
F
R
A
M
I
N
G
.
RU
N
D
O
W
N
T
O
T
O
P
O
F
F
O
U
N
D
A
T
I
O
N
WA
L
L
.
24
G
A
.
4
"
X
4
"
L
E
G
G
A
L
V
.
F
L
A
S
H
I
N
G
FR
O
M
W
A
L
L
T
O
B
E
L
O
W
C
U
L
T
U
R
E
D
ST
O
N
E
V
E
N
E
E
R
.
C
A
U
L
K
B
E
T
W
E
E
N
PO
R
C
H
C
A
P
A
N
D
F
L
A
S
H
I
N
G
PO
R
C
H
C
A
P
D
E
T
A
I
L
SC
A
L
E
=
N
.
T
.
S
.
MIN
.
N
E
T
C
L
E
A
R
O
P
E
N
I
N
G
H
E
I
G
H
T
O
F
2
4
"
(
F
O
R
A
W
I
D
E
W
I
ND
O
W
)
.
M
I
N
.
H
E
I
G
H
T
FR
O
M
F
L
O
O
R
T
O
C
L
E
A
R
O
P
E
N
I
N
G
N
O
T
T
O
E
X
C
E
E
D
4
4
"
.
4
4
"
M
A
X
.
T
O
C
L
E
A
R
O
P
E
N
I
N
G
TY
P
.
T
R
U
S
S
H
E
E
L
SC
A
L
E
=
N
.
T
.
S
.
P
E
R
P
L
A
N
project:revisions:Project number Date Drawn by Engineered by7707 SOUTH MAIN STREET MIDVALE, UT 84047 801.285.8885CRAIG WALL DESIGN EACH SUB-CONTRACTOR SHALL CHECK AND UNDERSTAND ALL DIMENSIONS, NOTES AND OTHER ASPECTS OF THIS PROJECT APPLICABLE TO THEIR TRADE AND AFFECTING OTHER TRADES PRIOR TO AND DURING CONSTRUCTION.NOTIFY DESIGNER OR ENGINEER IN WRITING OF ANY DISCREPANCIES OR CHANGES ON THE DRAWINGS BEFORE PROCEEDING WITH ANY WORK.EACH SUB-CONTRACTOR SHALL COORDINATE WORK WITH OTHER TRADE THROUGH THE GENERAL CONTRACTOR.THE DESIGNER WILL NOT ASSUME RESPONSIBILITY FOR ANY MISUSE OR MISREADING OF THESE PLANS. WHERE INFORMATION IS AVAILABLE BUT UNCLEAR, THE PERSON USING THESE PLANS IS RESPONSIBLE FOR CLARIFYING ANY QUESTIONS ACCORDING TO THE CONDITIONS STATED ABOVE.A5.0MARCH 26, 2021SOMMER RESIDENCE LOT 4 BLOCK 1 PINE BROOK ESTATES REXBURG, ID CWD N/A SECTIONS
MA
I
N
F
.
F
.
10
0
'
-0"
MAIN F.F.100'-0"
MA
I
N
T
O
P
P
L
A
T
E
10
9
'
-0"
MAIN TOP PLATE 109'-0"
FA
M
I
L
Y
R
O
O
M
T
.
P
.
11
1
'
-0"
GARAGE T.O.S.98'-6"
SC
A
L
E
1
/
4
"
=
1
'
-
0
"
SE
C
T
I
O
N
'
A
'
12
10
12
10
CR
A
W
L
SP
A
C
E
CR
A
W
L
SP
A
C
E
C
L
G
.
1
1
'
-
0
"
C
L
G
.
9
'
-
0
"
SL
O
P
E
T
O
D
R
A
I
N
SLOPE TO DRAIN project:revisions:Project number Date Drawn by Engineered by7707 SOUTH MAIN STREET MIDVALE, UT 84047 801.285.8885CRAIG WALL DESIGN EACH SUB-CONTRACTOR SHALL CHECK AND UNDERSTAND ALL DIMENSIONS, NOTES AND OTHER ASPECTS OF THIS PROJECT APPLICABLE TO THEIR TRADE AND AFFECTING OTHER TRADES PRIOR TO AND DURING CONSTRUCTION.NOTIFY DESIGNER OR ENGINEER IN WRITING OF ANY DISCREPANCIES OR CHANGES ON THE DRAWINGS BEFORE PROCEEDING WITH ANY WORK.EACH SUB-CONTRACTOR SHALL COORDINATE WORK WITH OTHER TRADE THROUGH THE GENERAL CONTRACTOR.THE DESIGNER WILL NOT ASSUME RESPONSIBILITY FOR ANY MISUSE OR MISREADING OF THESE PLANS. WHERE INFORMATION IS AVAILABLE BUT UNCLEAR, THE PERSON USING THESE PLANS IS RESPONSIBLE FOR CLARIFYING ANY QUESTIONS ACCORDING TO THE CONDITIONS STATED ABOVE.A5.1MARCH 26, 2021SOMMER RESIDENCE LOT 4 BLOCK 1 PINE BROOK ESTATES REXBURG, ID CWD N/A SECTIONS
WP
/
G
F
I
WP
/
G
F
I
WP/GFI
GFI
20"
MIN.
GF
I
20
"MIN
.
GFI
20"
MIN.
22
0
220
22
0
GF
I
GF
I
GFI
GFI
GFI
GF
I
GF
I
GF
I
GFIGFI
GF
I
GF
I
GFI
GF
I
SC
A
L
E
1
/
4
"
=
1
'
-
0
"
MA
I
N
F
L
O
O
R
E
L
E
C
T
R
I
C
A
L
P
L
A
N
ELE
C
.
PA
N
E
L
3 WAY SWITCH DUPLEX RECEPTACLE OUTLET -
T
A
M
P
E
R
R
E
S
I
S
T
A
N
T
CARBON MONOXIDE DETECTOREXHAUST FAN -
V
E
N
T
T
O
O
U
T
S
I
D
E
SURFACE MOUNT LIGHT FIXTUREGROUND FAULT INTERCEPT DUPLEX RECEPTACLE OUTLET WATER PROOF G.F.I. DUPLEX RECEPTACLE OUTLET SMOKE DETECTOR WIRE IN SERIES W/ BATTERY BACK-UPELECTRICAL LEGEND GFI WP/GFI3 COS NOTES:ALL OUTLETS MUST BE TAMPER RESISTANT PER 2017 NEC.ALL BEDROOM OUTLETS, LIGHTS, SWITCHES & SMOKE DETEC TORS SHALL BE ARC-FAULT PROTECTED.FIELD DETERMINE LOCATION OF ALL SWITCHES.PROVIDE METALLIC WATER SERVICE & CONCRETE ENCASED E LECTRODE PER 2017 NEC.PROVIDE BUBBLE COVERS ON ALL EXTERIOR OUTLETS.INSTALL 110V OUTLET WITHIN 25' OF A/C UNIT.INSTALLATION OF ALL ELECTRICAL COMPONENTS SHALL COM PLY WITH THE 2017 NEC REQUIREMENTS INCLUDING THE PLACEMENT OF OUTLETS AS SPECIFIED IN CHAPTER 2 AND WIRING METHODS AS SPECIFIED IN CHAPTER 3 (I.E. RECEPTACLES ARE REQUIRED WITHIN 6' OF WALL ENDS AND VERTICAL EDGES OF DOORWAYS AND ON ALL WALL SECTIONS AT LEAST 2' WIDE).220 V. OUTLET PENDANT LIGHT FIXTURE RECESSED CAN LIGHT CLG. FAN W/ LIGHT 2'X4' FLUORESCENT LIGHT FIXTURE
W
P
W
P
CO
GFI
GFI
GF
I
PW
R
F
O
R
D
.
W
.
PW
R
F
O
R
D
I
S
P
.
PO
W
E
R
F
O
R
G
A
R
A
G
E
DO
O
R
O
P
E
N
E
R
project:revisions:Project number Date Drawn by Engineered by7707 SOUTH MAIN STREET MIDVALE, UT 84047 801.285.8885CRAIG WALL DESIGN EACH SUB-CONTRACTOR SHALL CHECK AND UNDERSTAND ALL DIMENSIONS, NOTES AND OTHER ASPECTS OF THIS PROJECT APPLICABLE TO THEIR TRADE AND AFFECTING OTHER TRADES PRIOR TO AND DURING CONSTRUCTION.NOTIFY DESIGNER OR ENGINEER IN WRITING OF ANY DISCREPANCIES OR CHANGES ON THE DRAWINGS BEFORE PROCEEDING WITH ANY WORK.EACH SUB-CONTRACTOR SHALL COORDINATE WORK WITH OTHER TRADE THROUGH THE GENERAL CONTRACTOR.THE DESIGNER WILL NOT ASSUME RESPONSIBILITY FOR ANY MISUSE OR MISREADING OF THESE PLANS. WHERE INFORMATION IS AVAILABLE BUT UNCLEAR, THE PERSON USING THESE PLANS IS RESPONSIBLE FOR CLARIFYING ANY QUESTIONS ACCORDING TO THE CONDITIONS STATED ABOVE.E1.0MARCH 26, 2021SOMMER RESIDENCE LOT 4 BLOCK 1 PINE BROOK ESTATES REXBURG, ID CWD N/A MAIN FLOOR ELECTRICAL PLAN