Loading...
HomeMy WebLinkAboutJOIST - 07-00123 - 1049 Arctic Willow Dr - New SFRTrus Joist rim board NAILING REQUIREMENTS TJI® Joists at bearings: Two 8d (2Y2") box nails (1 each side), 1 Y2" minimum from end. Blocking panels, rim joist or rim board to bearing plate: TJI® blocking panels or rim joist: 10d (3") box nails at 6" o.c. This Joist rim board: Toenail with 10d (3") box nails at 6" o.c. or 16d (311") box nails at 12" o.c. Shear transfer: Connections equivalent to decking nail schedule. Rim board, rim joist or closure to TJI®joist: 13/4" width or less: Two 10d (3") box nails, one each at top and bottom flange. 21/6"thru 212" widths: Two 16d (311") box nails, one each at top and bottom flange. 3112" width: Toenail joist to rim joist with one 10d (3") box nail each side of joist top flange. 2x4 minimum squash blocks: Two 10d (3'r) box nails, one each at top and bottom flange. 611E 0 in', L DO NOT allow workers to walk on joists until braced. INJURY MAY RESULT. WARNING Joists are unstable until braced laterally Bracing Includes: • Blocking • Sheathing • Hangers • Rim Board • Stmt Lines • Rim Joist WARNING NOTES: DO NOT stack building materials on unsheathed joists. Stack only over beams or walls. Lack of concern for proper bracing during construction can result in serious accidents Under normal conditions if the following guidelines are observed, accidents will be avoided 1. All blocking, hangers, nm boards and rim Joists at the and supports of the TJI " Joists must be completely installed and property nailed. 2. Lateral strength, like a braced end wail or an existing deck, most be established at the ends of the bay. This can also be accomplished by a temporary or permanent deck (sheathing) fastened to the first 4 feet of joists at the end of the bay. 3. Safety bracing lines of 1x4 (minimum) must be nailed to a braced and wall or sheathed area as in note 2 and to each foist Without this bracing, buckling sideways or rollover Is highly probable under light construction toads - like a worker or one layer of unnalied sheathing, 4. Sheathing must be totally attached to aeon TJI a Joist before additional loads can be placed on the system. 5, Ends of cantlleyers require safety bracing on both the top and bottom flanges. 6. The flanges must remain straight within a tolerance of 34" from true alignment. C] u''/ MAR - 9 2007 ID) CITY OF R X UEE RG TJ-Xpert framrig plan reguies the Trus Joist Framer's Pc See Trus Joist Framer's Pocket Guiie for Product Trademark Information ■NO ROOF LOAD APPLIED 4nTJXpert. IeZ111111'a""b A**_ 142 O'�'JWWO r4 BANGER LIST - Simpson Strong -Tie Company, Inc.® Plot ID Qty Product Label Top Nails Face Nails Member Nails Notes H1 23 IUT11 10-N10 2-N10 Hanger Notes: LEVEL NOTES File Name: RJM MUIR CONST SPEC 2 03OB07.JOB Level Name: MUIR CONST Plotted: 3/8/2007 16:51 Design Statue: MUIR CONST... 3/8/2007 16f48 NOTE: Level design times indicated above assurance for proper level stacking. Design Methodology: ASD Floor Area Loading Is: 40psf Live Load and 15 ps£ Dead Load Maximum Joist Deflection; L/36C Live Load L/240 Total Load TJ -Pro Rating Information: Weighted Average: 40 Lowest Rating: 39 Highest Rating: 61 Glued & Nailed Decking is Required Direct Applied Ceilinq of 5/8" Gypsum is Required Floor Decking: 23/32" Panels (24" Span Rating) Normal O.C. Spacing = 1611* °Unless noted otherwise Scale: 1/4!' = 1' CREATED BY bmcwest 202 w main rexbuxq, ID 83940 11208)356-9292 FAX: (1208)35b-3299 SYMBOL LEGEND s Note from Operator Point Load Line Load Area Load ODetail Callout Label (See Framer's Pocket Guide) 1 of 1 FOR THE TJ-XPERT WARRANTY SEE FRAMER'S POCKET GUIDE TJ-Xpert 6.42 (#693) 66.42 136.42 S6.42 P6.42 JOIST AND BEAM LIST Plot ID Length Product Plies Qty A See Layout 11 7/0" TJI 110 joist 1 M1 13' 1 3/4" x 11 7/8" 1.9EMicrollam LVL 2 2 M2 8' 1 3/4"x 11 7/8" 1.9E Microllam LVL 1 1 ACCESSORIES LIST RMI 16' 1 1/4" x 11 7/8" 1,3E TimberStrand LSL 1 13 Shl 4' x 8' 23/32" Panels (24" Span Rating) 1 53 Rm, Rim Board LEVEL NOTES File Name: RJM MUIR CONST SPEC 2 03OB07.JOB Level Name: MUIR CONST Plotted: 3/8/2007 16:51 Design Statue: MUIR CONST... 3/8/2007 16f48 NOTE: Level design times indicated above assurance for proper level stacking. Design Methodology: ASD Floor Area Loading Is: 40psf Live Load and 15 ps£ Dead Load Maximum Joist Deflection; L/36C Live Load L/240 Total Load TJ -Pro Rating Information: Weighted Average: 40 Lowest Rating: 39 Highest Rating: 61 Glued & Nailed Decking is Required Direct Applied Ceilinq of 5/8" Gypsum is Required Floor Decking: 23/32" Panels (24" Span Rating) Normal O.C. Spacing = 1611* °Unless noted otherwise Scale: 1/4!' = 1' CREATED BY bmcwest 202 w main rexbuxq, ID 83940 11208)356-9292 FAX: (1208)35b-3299 SYMBOL LEGEND s Note from Operator Point Load Line Load Area Load ODetail Callout Label (See Framer's Pocket Guide) 1 of 1 FOR THE TJ-XPERT WARRANTY SEE FRAMER'S POCKET GUIDE TJ-Xpert 6.42 (#693) 66.42 136.42 S6.42 P6.42