Loading...
HomeMy WebLinkAboutSITE PLANS - 07-00081 - 50 Mill Race Rd - New SFRcomplete TJ-xpert framing plan requires the Trus Joist Framer's Pc See Trus Joisc Framer's Pocket Guide for Product Trademark Information 4UTI&Xpert. amn RnnF TInAn APPTITFn Trus Joist rim board A3 Web stiffeners 8" diameter maximum hole for required each Sig/ - 20" d " eep blocking panels; side at EIW 6" diameter maximum for blocking panels 9Y2" deep or shorter than 12" long. Do not cut flanges. Filler block; Attach with ten SOd (3") box nails, clinched, Use ten 16d (Az") box nails from each side with 31211 TJI* joist flange widths. Use fifteen nails with TJI* joist depths greater than 16". Trus Joist rim board Backer block: Install tight to top low (tight to bottom flange with face mount hangers). Attach with ten 10d (3") box nails, clinched when possible. Backer block bath skies of web with single TJI* joist H2 NAILING REQUIREMENTS TJI® Joists at bearings: Two Bid (2Y2') box nails (leach side), minimum from end. Blocking Danels. rim foist or rim board to bearing plate: TJI® blocking panels or rim joist: 1 Od (W) box nails at 6" o.c. This Joist rim board: Toenail with 10d (3") box nails at 6" o.c, or 16d (3Y") box nails at 12" o.c. Shear transfer: Connections equivalent to decking nail schedule Rim board, rim joist or closure to TJI ®joist: 1314"width or less: Two I Od (3") box nails, one each at top and bottom flange. 2116" thru 21112" widths: Two 16d (3Y") box nails, one each at top and bottom flange. 3Y2" width: Toenail joist to rim joist with one 10d (W) box nail each side of joist top flange. 2x4 minimum squash blocks: Two 10d (3") box nails, one each at top and bottom flange. (n- DO NOT allow workers to walk on joists until braced. INJURY MAY RESULT. WARNING Joists are unstable until braced laterally Bracing Includes: • Blocking • Sheathing • Hangers • Rim Board • Strut Lines • Rim Joist DO NOT stack building materials on unsheathed joists. Stack only over beams or walls. WARNING NOTES: Lack of concern for proper bracing during construction can result in serious accidents. Under normal conditions if the following guidelines are observed, accidents will be avoided. 1. All bucking, hangers, rim boards and rim joists at the end supports of the TJI a joists must be completely installed and properly nailed. 2. Lateral strength, like a braced and wall or an existing deck, must be established at the ends of the bay. This can also be accomplished by a temporary or permanent deck (sheathing) fastened to the first 4 feet of Joists at the end of the bay. 3. Safety bracing lines of 1x4 (minimum) must be naked to a braced end wall or sheathed area as In note 2 and to each Joist. Without this bracing, bucking sideways or rollover is highly probable under light construction loads - like a worker or one layer of unnalled sheathing. 4. Sheathing must be totally attached to each TJI a joist before additional loads can be placed on the system. 5. Ends of cantilevers require safety bracing on both the top and bottom flanges. 6. The flanges must remain straight within a tolerance of A' from true alignment. HANGER LIST - Simpson Strong -Tie Company, Inc.0 - t ID Qty Product Label Top Nails Face Nails Member Nails Notes Hi 6 IUS2.06/11.88 10-10d (5) Hanger Notes: (5) Backer Blocks Required JOIST AND BEAM LIST Plot ID Length Product Plies Qty A See Layout 11 7/8" TJI 110 joist 1 B See Layout 11 7/8" TJI 210 joist 1 ACCESSORIES LIST Bbl 1' 23/32" Backer Blocks 1 12 Rml 16, 1 1/4" x 11 7/8" 1.3E TimberStrand LSL 1 15 Bkl 1' 1.92" 11 7/8" TJI 210 Blocking Panels 1 9 Bki+ 1' 10" it 7/8" TJI 210 Blocking Panels 1 1 Shl 4' x 8' 23/32- Panels (24" Span Rating) 1 51 Bki, Random length blocking panel cuts Bk, Blocking Panels; Rm, Rim Board LEVEL NOTES File Name; RYAN SUAETTE HAMMER 012007.702 Level Name: MAIN FLOOR Plotted: 2/16/2007 15:48 Design Status: MAIN FLOOR... 1/22/2007 11:18 NOTE: Level design times indicated above provic assurance for proper level stacking. Design Methodology; ADD Floor Area Loading Is: 40psf Live Load and 15 psf Dead Load Maximum Joist Deflection: L/360 Live Load L/240 Total Load TJ-Pro Rating Information: Weighted Average; 49 Lowest Rating: 42 Hiahest Rating: 73 Glued 6 Nailed Decking is Reauired Direct Applied Ceiling of 5/8" Gypsum is Rewired Floor Decking: 23/32" Panels (24" Span Rating) Normal O.C. Spacing = 1611* *Unless noted otherwise Scale:1/4" m 1' CREATED BY bmcwest 202 w main rexburq, ID 83990 (12081356-9292 FAX: (1208)35fi-3299 SYMBOL LEGEND I 5ote from Operator Line Load Area Load ODetail Callout Label (See Framer's Pocket Guide) 1 of 1 FOR THE TJ-XPERT WARRANTY SEE FRAMER'S POCKET GUIDE TJ-Xpert e.42 (111693) C6.42 D6.42 38.42 138.42