Loading...
HomeMy WebLinkAboutTRUSSES - 07-00080 - 354 Oaktrail Dr - New SFRFRANKLIN TRUSS 515 WEST MAIN ST To: Delivery List JEROME , ID 83338 FRANKLIN POCATELLO Phone:(208)324.8161 Fax:(208)324-6973 Job Number. Page: Date: 1 01-31-2007 - 8:17:53 AM Project Block No: Model: Lot No: Project ID: 0129KH Contact Site: Office: Deliver TO: KARTCHNER HOMES Account No: Designer: 303490627 BOB WHILLOCK Name: Phone: NEWPORT B WITH DORMER Salesperson: JOHN F REXBURG Quote Number. Tentative Delive Date: Profile: Qty: Truss Id: Span: Truss Type: pitch LOH ROH I Load By: 1 Al 20-11-8 GABLE -0-1 8.00 0-0-0 0-0-0 103 lbs. each 0.00 8-1-6 6 A2 97 lbs. each 20-11-8 ROOFTRUSS 8.00 0.00 1-2-0 1-2.0 5 A3 95lbs. each 20-9-0 ROOF TRUSS 8- 1-6 8.00 0.00 1-2-0 0-0-0 1 B1 21-3-12 GABLE 10-8-2 6.00 0-0-0 0-0-0 140 lbs. each 3 Rows Let Bra 0.00 11-8-1 5 B2 21-9-0 ROOF TRUSS 6.00 1-6-0 0-0.0 1161bs. each 5.00 s0-5-4 11-8-1 2 B3 21-9-0 ROOFTRUSS 6.00 1-6-0 0-0-0 123lbs. each 5.00 s0-5-4 2 B4 19-0-8 ROOFTRUSS 10-7-3 6.00 1-6-0 0.0-0 109 lbs. each 5.00 8-10-3 1 C1 25-0-8 GABLE 6.00 0-0-0 0-0-0 159lbs. each 0.00 7 C2 26-4-0 ROOF TRUSS 8-it-1 6.00 0-0-0- 1-6-0 135 lbs. each 3 Rows Lat Bra 0.00 s 0 - 3 - 8 9-11-1 2 C3 28-0-8 ROOF TRUSS 6.00 0-0-0 1-6-0 158 lbs. each 2 Rows Lat Bra 0.00 11 C4 29-0-8 ROOF TRUSS 9-11-1 6.00 0-0.0 1-6-0 160 lbs. each 2 Rows Lat Bra 0.00 7 CS 1741bs. each 29-0-8 8-00 GABLE 2 Rows Lat Bra 1 6.00 0.00 0-0-0 0-0-0 MISC. ITEMS Quantity: Description: D (C {�/ j� 11 L� 14 HUS26 D FEB 2 6 2007 CITY OF REXBURG Above listed items have been designed to plans and or jobsite conditions. (exceptions listed to right). Received Thank You for your Business. 0700080 3Oaktrail Dr-Kartchner Job Truss T •s Type QtY Ply 0129KH Al *i;BLE Job Reference (optional) FRANKLIN BUILDING SUPPLY, JEROME, ID. 83338 6.400 s Aug 12006 MiTek Industries, Inc. Wed Jan 31 07:29:38 2007 Page 1 10-5-12 20-11-8 10-5-12 10-5-12 3x5 = Scale = 1:44.3 2x4 11 6 2x4 11 7 2x4 11 2x4 11 5 8.00 12 2x4 11 4 8 2x4 11 2x4 I I 3T 29 0 2x4 11 2 10 1 11 a -o 0 0 3x5 20 19 18 17 16 15 14 13 12 3x5 2x4 II 2x4 II 2x4 11 2x4 II 2x4 II 2x4 II 3x5 = 2x4 II 2x4 11 20-11-8 20-11-8 Plate Offsets X 6:0-2-8 Ed e LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) Vdefl Ud PLATES GRIP TCLL 35.0 Plates Increase 1.15 TC 0.12 Vert(LL) n/a - n/a 999 MT20 220/195 TCDL 8.0 Lumber Increase 1.15 BC 0.08 Vert(TL) n/a - n/a 999 BCLL 0.0 Rep Stress Incr NO WB 0.09 Horz(TL) 0.00 11 n/a n/a BCDL 8.0 Code IRC2003/TP12002 (Matrix) Weight: 103 lb LUMBER BRACING TOP CHORD 2 X 4 DF No. 1&Btr TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins. BOT CHORD 2 X 4 DF No. 1&Btr BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2 X 4 DF Stud/Std REACTIONS (lb/size) 1=146/20-11-8, 11=146/20-ll-8, 17=171/20-11-8, 18=220/20-11-8, 19=159/20-11-8, 20=327/20-11-8, 16=171/20-11-8, 15=220/20-11-8, 14=159/20-11-8, 12=327/20-11-8 Max Horz 1=-210(load case 3) Max Upliftl=-30(load case 3), 17=-24(load case 4), 18=-103(load case 5), 19=-65(load case 5), 20=-136(load case 5), 15=-105(load case 6), 14=-64(load case 6), 12=-136(load case 6) Max Gravl=146(load case 1), 11=146(load case 1), 17=171(load case 1), 18=222(load case 9), 19=159(load case 1), 20=327(load case 9), 16=171(load case 1), 15=222(load case 10), 14=159(load case 1), 12=327(load case 10) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-179/110, 2-3=-115/97. 3-4=-76/93, 4-5=-79/121, 5-6=-63/108, 6-7=-63/106, 7-8=-79/103, 8-9=-73/42, 9-10=-89/36, 10-11=-136/62 BOT CHORD 1-20=-37/150, 19-20=-37/150, 18-19=-37/150, 17-18=-37/150, 16-17=-37/150, 15-16=-37/150, 14-15=-37/150, 13-14=-37/150, 12-13=-37/150, 11-12=-37/150 WEBS 5-17=-142/42, 4-18=-185/122, 3-19=-144/87, 2-20=-252/148, 7-16=-142/3, 8-15=-185/124, 9-14=-144/87, 10-12=-252/148 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 90mph; h=25ft; TCDL=4.0psf; BCDL=4.8psf; Category II; Exp C; enclosed; MWFRS gable end zone; cantilever left and right exposed; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33. 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see MiTek "Standard Gable End Detail" 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) This truss requires plate inspection per the Tooth Count Method when this truss is chosen for quality assurance inspection. 6) Gable requires continuous bottom chord bearing. 7) Gable studs spaced at 2-0-0 oc. 8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 30 lb uplift at joint 1, 24 lb uplift at joint 17, 103 lb uplift at joint 18, 65 lb uplift at joint 19, 136 lb uplift at joint 20, 105 lb uplift at joint 15, 64 lb uplift at joint 14 and 136 lb uplift at joint 12. 9) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard 0129KH I ruse i ^ -S Type - Qty Ply — A2 16wOF TRUSS 5 1 s Aug 12006 MTek Industries, Inc. Wed Jan -1-2-0 5-5-5 10-5-12 15-6-3 20-11-8 22-1-8 1-2-0 5-5-5 5-0-7 5-0-7 5-5-5 1-2-0 4x6 11 Scale = 1:441 4 - -- IV V a 3x5 = 3x5 = 3x5 = 3x5 = 7-1-7 13-10-1 20-11-8 7-1-7 6-8-9 7-9-7 Plate Offsets 2:0-2-9 0-1-8 6:0-2-9 0-1-8 LOADING (psf) TCLL 35.0 SPACING 2-0-0 CSI DEFL in (loc) I/defl Ud PLATES GRIP TCDL 8.0 Plates Increase 1.15 Lumber Increase 1.15 TC 0.27 BC 0.28 Vert(LL) -0.05 6-8 >999 360 MT20 220/195 BCLL 0.0 Rep Stress Incr YES WB 0.13 Vert(TL) Horz(TL) -0.12 0.03 6-8 6 >999 n/a 180 n/a BCDL 8.0 Code IRC2003/TPI2002 (Matrix) I I Weight: 97 lb LLIYIOGR TOP CHORD 2 X 4 DF No. 1&Btr BOT CHORD 2 X 4 DF No.1 &Btr WEBS 2 X 4 DF No. 1&Btr *Except* W1 2 X 4 DF Stud/Std, W4 2 X 4 DF Stud/Std REACTIONS (lb/size) 2=1174/0-3-8, 6=1174/0-3-8 Max Horz 2=224(load case 4) Max Uplift2=-273(load case 5), 6=-273(load case 6) BRACING TOP CHORD Structural wood sheathing directly applied or 5-1-10 oc purlins. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/59, 2-3=-1529/276, 3-4=-1327/333, 4-5=-1327/333, 5-6=-15291276, 6-7=0/59 BOT CHORD 2-10=-213/1159, 9-10=-46/785, 8-9=-46/785, 6-8=-136/1159 WEBS 3-10=-391/229, 4-1 0=- 157/527, 4-8=-157/527, 5-8=-391/229 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 90mph; h=25ft; TCDL=4.Opsf; BCDL=4.8psf; Category II; Exp C; enclosed; MWFRS gable end zone; cantilever left and right exposed; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) This truss requires plate inspection per the Tooth Count Method when this truss is chosen for quality assurance inspection. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 273 lb uplift at joint 2 and 273 lb uplift at joint 6. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss T % Type Qty Ply 0129KH A3 F TRUSS 5 1 14=0� Job Reference (optional) FRANKLIN BUILDING SUPPLY, JEROME, ID. 83338 6.400 s Aug 12006 MTek Industries, Inc. Wed Jan 31 07:29:40 2007 Page 1 -1-2-01 5-5-5 10-5-12 15-6-3 20-9-0 , 1-2-0 5-5-5 5-0-7 5-0-7 5-2-13 4x6 II Scale=1:43.6 4 8.00 F12 2x4 2x4 , 3 W 3 5 1 1 4 6 ti 2 N Io 3x5 = 9 8 7 5x6 = 3x5 = 3x5 = 3x5 = 7-1-7 13-10-1 20-9-0 7-1-7 6-8-9 6-10-15 Plate Offsets 2:0-2-9 0-1-8 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl Ud PLATES GRIP TCLL 35.0 Plates Increase 1.15 TC 0.27 Vert(LL) -0.05 6-7 >999 360 MT20 220/195 TCDL 8.0 Lumber Increase 1.15 BC 0.29 Vert(TL) -0.12 2-9 >999 180 BCLL 0.0 Rep Stress Incr YES WB 0.14 Horz(TL) 0.03 6 n/a n/a BCDL 8.0 Code IRC2003/TPI2002 (Matrix) Weight: 95 lb LUMBER BRACING TOP CHORD 2 X 4 DF No.1 &Btr TOP CHORD Structural wood sheathing directly applied or 5-2-0 oc purlins. BOT CHORD 2 X 4 DF No. 1&Btr BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 2 X 4 DF No.1&Btr *Except* W1 2 X 4 DF Stud/Std, W4 2 X 4 DF Stud/Std WEDGE Right: 2 X 4 DF Stud/Std REACTIONS (lb/size) 2=1163/0-3-8, 6=1035/0-5-8 Max Horz 2=237(load case 4) Max Uplift2=-272(load case 5), 6=-195(load case 6) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/59, 2-3=-1510/273, 3-4=-1308/330, 4-5=-1290/338, 5-6=-1488/278 BOT CHORD 2-9=-229/1143, 8-9=-631770, 7-8=-63/770, 6-7=-149/1112 WEBS 3-9=-391/229, 4-9=-156/528, 4-7=-163/501, 5-7=-361/226 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 90mph; h=25ft; TCDL=4.0psf; BCDL=4.8psf; Category II; Exp C; enclosed; MWFRS gable end zone; cantilever left and right exposed; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) This truss requires plate inspection per the Tooth Count Method when this truss is chosen for quality assurance inspection. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 272 lb uplift at joint 2 and 195 lb uplift at joint 6. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard Job Truss I Try iss Type Qty Ply O129KH B1 BLE 1 1 FRANKLIN BUILDING SUPPLY, JEROME, ID. 83338 Job Reference (optional) 6.400 s Aug 12006 MiTek Industries, Inc. Wed Jan 31 07:58:16 2007 Page 1 21-3-12 21-3-12 2x4 11 Scale=1:62.1 3x5 11 12 6.00 12 2x4 11 11 2x4 11 10 2x4 11 9 2x4 11 8 T 2x4 II 2x4 II 7 E 1 V2 ' 3x5 -5-, 6 S19 2x4 115 g 2x4 11 3 4 5 6 4 S 3 q 1 2 0 0 3x5 22 21 20 19 18 17 16 15 14 13 2x4 11 2x4 11 2x4 11 2x4 11 2x4 11 2x4 11 5x6 = 2x4 11 3x5 11 � 21-3-12 2x4 11 21-3-12 Plate Offsets 16:0-3-0 0-3-0 LOADING (psf) SPACING 2-" CSI DEFL in (toe) I/deft Ud PLATES GRIP TCLL 35.0 Plates Increase 1.15 TC 0.29 Vert(LL) n/a - n/a 999 MT20 220/195 TCDL 8.0 Lumber Increase 1.15 BC 0.32 Vert(TL) n/a - n/a 999 BCLL 0.0 Rep Stress Incr NO WB 0.14 Horz(TL) 0.00 13 n/a n/a BCDL 8.0 Code IRC20031TPI2002 (Matrix) Weight; 141 lb LUMBER BRACING TOP CHORD 2 X 4 DF No.1&Btr TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2 X 4 DF No.1 &Btr except end verticals. WEBS 2 X 4 DF No.1&Btr BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing, Except: OTHERS 2 X 4 DF Stud/Std *Except* 10-0-0 oc bracing: 15-16,14-15,13-14. ST8 2 X 4 DF No.1 &Btr, ST9 2 X 4 DF No.1 &Btr WEBS 1 Row at midpt 12-13, 10-15, 11-14 ST10 2 X 4 DF No. 1&Btr REACTIONS (lb/size) 13=44/21-3-12, 1=142/21-3-12, 22=356/21-3-12, 21=145/21-3-12, 20=218/21-3-12, 19=200/21-3-12, 18=206/21-3-12, 17=201/21-3-12, 16=205/21-3-12, 15=213/21-3-12, 14=169/21-3-12 Max Horz 1=437(load case 4) Max Upliftl3=-78(load case 4), 22=-120(load case 5), 21=49(load case 5), 20=-74(load case 5), 19=-68(load case 5), 18=-70(load case 5), 17=-67(load case 5), 16=-77(load case 5), 15=49(load case 5), 14=-100(load case 5) Max Grav 13=88(load case 3), 1=155(load case 4), 22=356(load case 1), 21=145(load case 1), 20=218(load case 1), 19=200(load case 1), 18=206(load case 1), 17=201(load case 1), 16=205(load case 1), 15=213(load case 1) , 14=169(load case 1) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-372/72, 2-3=-328/26, 34=-303/27, 4-5=-299/43, 5-6=-274/45, 6-7=-245/58, 7-8=-217/72, 8-9=-188/86, 9-10=-160/100, 10-11=-132/116, 11-12=-51/53, 12-13=-68/119 BOT CHORD 1-22=-88/115, 21-22=-88/115, 20-21=-88/115, 19-20=-88/115, 18-19=-88/115, 17-18=-88/115, 16-17=-88/115, 15-16=-89/114, 14-15=-89/114, 13-14=-89/114 WEBS 2-22=-274/134, 3-21=-135/71. 5-20=-181/92, 6-19=-170187, 7-18=-173/89, 8-17=-171/88, 9-16=-173/89, 10-15=-179/97, 11-14=-153/166 NOTES 1) Wind: ASCE 7-02; 90mph; h=25ft; TCDL=4.Opsf, BCDL=4.8psf, Category ll; Exp C; enclosed; MWFRS gable end zone; cantilever left and right exposed; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33. 2) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see MiTek "Standard Gable End Detail" 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) This truss requires plate inspection per the Tooth Count Method when this truss is chosen for quality assurance inspection. 5) Gable requires continuous bottom chord bearing. 6) Gable studs spaced at 2-M oc. 7) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 78 lb uplift at joint 13, 120 lb uplift at joint 22, 49 lb uplift at joint 21, 74 lb uplift at joint 20, 68 lb uplift at joint 19, 70 lb uplift at joint 18, 67 lb uplift at joint 17, 77 lb uplift at joint 16, 49 lb uplift at joint 15 and 100 lb uplift at joint 14. 8) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard lss O129KH B2��OF TRUSS 5 1 FRANKLIN BUILDING SUPPLY, JEROME. ID. 33338 Job Reference o Gonal 6.400 s Aug 12006 MiTek Industries, Inc. Wed Jan 31 07:58:17 2007 21-9-0 -1-6-0 4-0-0 6-5-8 13-2-1 19-10-10 1-3-12 1-6-0 4-0-0 2-5-8 6-8-9 6-8-9 K %Z Scale = 1:61, 26," 8 LO N LO 13 6-*J 21-9-0 4-0-0 9yA612-12-,eA = 13-2-1 19-10-10 21-3-12 , 4-M 2-2-12 6-8-9 6-8-9 1-5-2 0-2-12 0-5-4 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud PLATES GRIP TCLL 35.0 Plates Increase 1.15 TC 0.70 Vert(LL) -0.03 10-11 >999 360 MT20 220/195 TCDL 8.0 Lumber Increase 1.15 BC 0.23 Vert(TL) -0.08 10-11 >999 180 BCLL 0.0 Rep Stress Incr NO WB 0.54 Horz(TL) 0.02 9 n/a n/a BCDL 8.0 Code IRC2003/TPI2002 (Matrix) Weight: 116 lb LUMBER BRACING TOP CHORD 2 X 4 DF No.1 &Btr TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2 X 4 DF No.1 &Btr except end verticals. WEBS 2 X 4 DF Stud/Std BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except: 6-0-0 oc bracing: 11-12. REACTIONS (lb/size) 9=828/0-5-8, 2=452/0-3-8, 12=1951/0-5-8 Max Horz2=380(load case 5) Max Uplift9=-253(load case 5), 2=-66(load case 5), 12=494(load case 5) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/59, 2-3=-266/0, 3-4=-277/503, 4-5=-1065/156, 5-6=-904/162, 6-7=-506/68, 7-8=-167/93, 8-9=-100/241 BOT CHORD 2-13=-145/156, 12-13=-145/156, 11-12=-458/30, 10-11=-315/895, 9-10=-91/277 WEBS 3-13=0/73, 3-12=-650/157, 4-12=-1268/432, 4-11=-294/1214, 6-11=-463/209, 6-10=-522/237, 7-10=-117/490, 7-9=-1108/373 NOTES 1) Wind: ASCE 7-02; 90mph; h=25ft, TCDL=4.Opsf, BCDL=4.8psfi Category II; Exp C; enclosed; MWFRS gable end zone; cantilever left and right exposed; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33. 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) This truss requires plate inspection per the Tooth Count Method when this truss is chosen for quality assurance inspection. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 253 lb uplift at joint 9, 66 lb uplift at joint 2 and 494 lb uplift at joint 12. 5) This truss is designed in accordance with the 2003 Intemational Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 510 lb down and 120 lb up at 4-1-12 on top chord. The design/selection of such connection device(s) is the responsibility of others. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Regular. Lumber Increase=1.15, Plate Increase= 1. 15 Uniform Loads (pif) Vert: 1-3=-86, 3-8=-111(F=-25), 2-12=-16, 10-12=-16, 9-10=-16 Concentrated Loads (lb) Vert: 3=-510(F) 0129KH J B3 �wOOF TRUSS M if O 21-9-0 1-6-0 4-1-12 8-11-0 14-4-13 19-10-10 1-3-12 1-6-0 4-1-12 4-9-4 5-5-13 5-5-13 1%-?- 20-541 1 8 f%f% r_ w n 3x0 = 14 13 3x5 = 2x4 11 21-9-0 4-1-12 8-8-4 ZI 0— 14-4-13 19-10-1p 1-3-12 4-1-12 4-6-8 0-2-12 5-5-13 5-5-13 1-5-2 0-5-4 LOADING (psf) SPACING 2-0-0 TCLL 35.0 Plates Increase 1.15 TCDL 8.0 Lumber Increase 1.15 BCLL 0.0 Rep Stress Incr NO BCDL 8.0 Code IRC2003/TPI2002 LUMBER TOP CHORD 2 X 4 DF No.1 &Btr BOT CHORD 2 X 4 DF No. 18Btr *Except* 132 2 X 4 DF Stud/Std WEBS 2 X 4 DF Stud/Std Inc. 31 Scale: 3/16" CS1 DEFL in (loc) I/deft L/d PLATES GRIP TC 0.45 Vert(LL) -0.03 14 >999 360 MT20 220/195 BC 0.55 Vert(TL) -0.04 14 >999 180 WB 0.71 Horz(TL) 0.01 9 n/a n/a (Matrix) Weight: 123 lb BRACING TOP CHORD Structural wood sheathing directly applied or 5-8-9 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 3-5-8 oc bracing. REACTIONS (lb/size) 9=623/0-5-8, 2=943/0-3-8, 13=2171 /0-5-8 Max Horz 2=380(load case 5) Max Uplift9=-200(load case 5), 2=-184(load case 5), 13=-548(load case 5) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/59, 2-3=-1333/82, 3-4=-278/596, 4-5=-274/724, 5-6=-609/77, 6-7=-374/54, 7-8=-121/71, 8-9=-52/139 BOT CHORD 2-14=-357/1110, 13-14=-20/49, 12-13=-2116/562, 5-12=-1257/405, 11-12=-570/51, 10-11=-186/471, 9-10=-81/195 WEBS 3-14=-214/142, 12-14=-346/1091, 3-12=-1682/407, 5-11=-203/953, 6-11=-467/178, 6-10=-226/148, 7-10=-89/293, 7-9=-778/278 NOTES 1) Wind: ASCE 7-02. 90mph; h=25ft; TCDL=4.Opsfi BCDL=4.8psf; Category II; Exp C; enclosed; MWFRS gable end zone; cantilever left and right exposed; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33. 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) This truss requires plate inspection per the Tooth Count Method when this truss is chosen for quality assurance inspection. 4) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 200 lb uplift at joint 9, 184 lb uplift at joint 2 and 548 lb uplift at joint 13. 5) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. 6) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 510 lb down and 120 lb up at 4-1-12, and 510 lb down and 120 lb up at 4-1-12 on top chord. The design/selection of such connection device(s) is the responsibility of others. 7) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B). LOAD CASE(S) Standard 1) Regular. Lumber Increase=1.15, Plate Increase= 1. 15 Uniform Loads (plf) Vert: 1-3=-86, 3-8=-111(F=-25), 2-13=-16, 10-12=-16, 9-10=-16 Concentrated Loads (lb) Vert: 3=-1020(F=-510) 0129KH I B4 I F TRUSS 12 1 11 '"0' n 0 6.400 s Aug 1 2006 MiTek ,-1-6-0, 4-8-12 8-11-0_ 13-10-0 19-0-8 1-6-0 4-8-12 4-2-4 4-11-0 5-2-8 4x8 Scale = 1 7 oxo— 12 11 3x5 = 2x4 11 4-8-12 8-11-0 13-10-0 19-0-8 4-8-12 4-24 4-11-0 5-2-8 1 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl Ud PLATES GRIP TCLL 35.0 Plates Increase 1.15 TC 0.40 Vert(LL) -0.01 8-9 >999 360 MT20 220/195 TCDL 8.0 Lumber Increase 1.15 BC 0.32 Vert(TL) -0.02 2-12 >999 180 BCLL 0.0 Rep Stress Incr YES WB 0.21 Horz(TL) -0.00 14 n/a n/a BCDL 8.0 Code IRC2003/TPI2002 (Matrix) Weight: 109 lb LUMBER BRACING TOP CHORD 2 X 4 DF No. 1&Btr TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc pudins, BOT CHORD 2 X 4 DF No.1 &Btr *Except* except end verticals. B2 2 X 4 DF Stud/Std BOT CHORD Rigid ceiling directly applied or 5-5-12 oc bracing. WEBS 2 X 4 DF Stud/Std *Except' W10 2 X 4 DF No.1 &Btr REACTIONS (lb/size) 2=507/0-3-8, 11=1117/0-5-8, 14=406/0-3-8 Max Horz2=425(load case 5) Max Uplift2=-65(load case 5), 11=-291(load case 5), 14=-175(load case 5) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=0/59, 2-3=-365/0, 3-4=-172/0, 4-5=-220/295, 5-6=-413/4, 6-7=-416/123, 8-13=0/90, 7-13=0/90 BOT CHORD 2-12=-159/238, 11-12=-13/2, 10-11=-1087/305, 5-10=-737/265, 9-10=-211/0, 8-9=-31/85 WEBS 3-12=0/140, 4-10=-470/123, 5-9=-91/480, 6-9=-442/228, 10-12=-153/243, 7-9=-203/364, 7-14=-408/176, 13-14=-20/43 NOTES 1) Wind: ASCE 7-02; 90mph; h=25ft; TCDL=4.Opsf; BCDL=4.8psf; Category II; Exp C; enclosed; MWFRS gable end zone; cantilever left and right exposed; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33. 2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 3) This truss requires plate inspection per the Tooth Count Method when this truss is chosen for quality assurance inspection. 4) Bearing at joint(s)14 considers parallel to grain value using ANSI/TPI 1 angle to grain formula. Building designer should verify capacity of bearing surface. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 65 Ib uplift at joint 2, 291 Ib uplift at joint 11 and 175 lb uplift at joint 14. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard 0129KH IC1 ( LF I It .1 1 '"M� I Job Reference (optional) s Aug 12006 MiTek Industries, Inc. Wed Jan 31 07:58:19 2007 Page 7-4-10 25-0-8 7-4-10 17-7-14 3x5 = Scale = 1: 6.00 12 6 29 28 27 26 25 24 23 22 21 20 19 18 17 3x5 Y -o 0 3x5 = 5x6 = f-- 25-0-8 -� 25-0-8 Plate Offsets 6:0-2-8 Ed a 21:0-240-0-4 - LOADING (psf) TCLL 35.0 SPACING 2-0-0 Plates Increase 1.15 ^S? TC 0.19 DEFL in (loc) Vdefl L/d PLATES GRIP TCDL 8.0 Lumber Increase 1.15 BC 0.08 Vert(LL) n/a 1 Vert(TL) n/a - n/a 999 - n/a qQ9 MT20 220/195 BCLL 0.0 Rep Stress Incr NO WB 0.16 Horz(TL) 0.01 16 ni2 n/a BCDL 8.0 Code IRC2003/TP12002 (Matrix) Weight: 159 lb LUMBER BRACING TOP CHORD 2 X 4 DF No.1&Btr BOT CHORD 2 X 4 DF No. 1&Btr TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, WEBS 2 X 4 DF Stud/Std BOT CHORD except end verticals. Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2 X 4 DF Stud/Std *Except* ST2 2 X 4 DF No.1 &Btr, ST6 2 X 4 DF No.1 &Btr REACTIONS (lb/size) 29=126/25-0-8, 26=189/25-0-8, 27=203/25-0-8, 28=218/25-0-8, 25=188/25-0-8, 24=206/25-0-8, 23=204/25-0-8, 22=204/25-0-8, 20=203/25-0-8, 19=207/25-0-8, 18=192125-0-8, 17=245/25-0-8, 16=92/25-0-8 Max Horz 29=-257(load case 3) Max Uplift29=-52(load case 5), 27=-79(load case 5), 28=-89(load case 5), 25=-20(load case 3), 24=-82(load case 6), 23=-68(load case 6), 22=-69(load case 6), 20=-69(load case 6), 19=-70(load case 6), 18=-65(load case 6), 17=-830oad case 6), 16=-16(load case 4) Max Grav29=126(load case 1), 26=189((oad case 1), 27=206(load case 9), 28=218(load case 9), 25=188(load case 1) , 24=208(load case 10), 23=204(load case 1), 22=204(load case 10), 20=203(load case 1), 19=207(load case 10), 18=192(load case 1), 17=245(load case 10), 16=92(load case 1) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-29=-73188, 1-2=-67/86, 2-3=41/90, 34=-46/134, 4-5=47/188, 5-6=-40/177, 6-7=40/179, 7-8=46/201, 8-9=-09/162, 9-10=-77/131, 10-11=-106/107, 11-12=-134/93, 12-13=-163R9, 13-14=-184/65, 14-15=-191/59, 15-16=-221/51 BOT CHORD 28-29=-36/208, 27-28=-36/208, 26-27=-36/208, 25-26=-36/208, 24-25=36/208, 23-24=-36/208, 22-23=-36/208, 21-22=-36/208, 20-21=-36/208, 19-20=-36/208, 18-19=-36/208, 17-18=-36/208, 16-17=-36/208 WEBS 5-26=-159/11, 4-27=-174/106, 3-28=-184/83, 2-29=-104/62, 7-25=-159/37, 8-24=-176/101, 9-23=-172/87, 10-22=-172/88, 11-20=-172/88, 12-19=-173/89, 13-18=-166/86, 15-17=-194/96 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind ASCE 7-02; 90mph; h=25t1; TCDL=4.Opsf; BCDL=4.8psf, Category II; Exp C; enclosed; MWFRS gable end zone; cantilever left and right exposed; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33. 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see MiTek "Standard Gable End Detail" 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. '5) All plates are 2x4 MT20 unless otherwise indicated. 6) This truss requires plate inspection per the Tooth Count Method when this truss is chosen for quality assurance inspection. 7) Gable requires continuous bottom chord bearing. 8) Gable studs spaced at 2-0-0 oc. 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 52 lb uplift at joint 29, 79 lb uplift at joint 27, 89 lb uplift at joint 28, 20 lb uplift at joint 25, 82 lb uplift at joint 24, 68 lb uplift at joint 23, 69 lb uplift at joint 22, 69 lb uplift Cont; oind o0ri bae 70 lb uplift at joint 19, 65 lb uplift at joint 18, 83 lb uplift at joint 17 and 16 lb uplift at joint 16. Job Truss T-•--tsType Qty 0129KH C2 1�OF TRUSS 7FRANKLIN 7lic RLIILnwr: CIIpp1 v i=anRAC in olego D RE v.yuu s Aug 1 zuub mi I ex Industries, Inc. Wed Jan 31 07:58:21 2007 Pane 1 -0A-1 7-2-14 I 12-11-15 18 8 15 25 0 8 ,26-6 8, 0-3-8 7-2-14 5-9-1 5-9-1 6-3-9 1-6-0 06 = Scale = 1:53 6.00 12 2 IL I 10 9 8 0�0 — 2x4 II 4x8 = 3x5 = 3x5 = 2x4 II -OLD-8 7-2-14 12-11-15 18-8-15 25-0-8 0-3-8 7-2-14 5-9-1 5-9-1 6-3-9 Plate Offsets X 1:0-3-0 0-1-8 LOADING (psf) TCLL 35.0 SPACING 2-0-0 Plates Increase 1.15 CSI TC 0.57 DEFL in (loc) I/deft Ud PLATES GRIP TCDL 8.0 Lumber Increase 1.15 BC 0.37 Vert(LL) Vert(TL) -0.07 -0.13 8 >999 360 8-10 >999 180 MT20 220/195 BCLL 0.0 BCDL 8.0 Rep Stress lncr YES Code IRC2003/TP12002 WB 0.49 (Matrix) Horz(TL) 0.04 6 n/a n/a Weight: 136 lb LUMBER TOP CHORD 2 X 4 DF No. 1&Btr BRACING BOT CHORD 2 X 4 DF No.1&Btr TOP CHORD Structural wood sheathing directly applied or 4-1-9 oc purlins, WEBS 2 X 4 DF No. 1&Btr *Except* BOT CHORD except end verticals. Rigid ceiling directly applied or 10-0-0 oc bracing. W3 2 X 4 DF Stud/Std, W4 2 X 4 DF Stud/Std, W5 2 X 4 DF Stud/Std WEBS 1 Row at midpt 2-11, 3-11, 1-12 REACTIONS (lb/size) 12=125210-5-8, 6=1418/0-5-8 Max Horz 12=-290(load case 3) Max UPliftl 2=-241 (load case 6), 6=-353(load case 6) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-969/273, 2-3=-938/262, 3-4=-1458/347, 4-5=-1573/328, 5-6=-2227/419, 6-7=0/59, 1-12=-1188/275 BOT CHORD 11-12=-28/246, 10-11=-82/1304, 9-10=-251/1870, 8-9=-251/1870, 6-8=-251/1870 WEBS 2-11=-52/286, 3-11=-846/282, 3-10=-52/401, 5-10=-646/214, 5-8=0/231, 1-11=-146/863 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 90mph; h=25ft; TCDL=4.Opsf, BCDL=4.8psf, Category II; Exp C; enclosed; MWFRS gable end zone; cantilever left and right exposed; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33. 3) This truss has been designed for a 10.0 psf bottom chord live load nonooncurrent with any other live loads. 4) This truss requires plate inspection per the Tooth Count Method when this truss is chosen for quality assurance inspection. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 241 lb uplift at joint 12 and 353 lb uplift at joint 6. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard 129KH I C3 I kW6F TRUSS 12 1 11 'ftv' , JEROME, ID. 83338 6.400 s Aug 12006 MiTek Industries, Inc. Wed Jan 31 5-3-3 10-2-14 15-11-15 21-8-15 28-0-8 29-6-8 5-3-3 4-11-11 5-9-1 5-9-1 6-3-9 1-6-0 4x6 = Scale =1:55 6.00 F12 3 14 13 12 11 10 9 4x0 = 2x4 11 3x5 = 4x8 = 3x5 = 3x5 = 2x4 11 5-3-3 10-2-14 15-11-15 21-8-15 28-0-8 , 5-3-3 4-11-11 5-9-1 5-9-1 6-3-9 LOADING (psQ SPACING 2-0-0 CSI TCLL 35.0 Plates Increase 1.15 TC 0.75 TCDL 8.0 Lumber Increase 1.15 BC 0.41 BCLL 0.0 Rep Stress Incr YES WB 0.49 BCDL 8.0 Code IRC2003/TPI2002 (Matrix) LUMBER TOP CHORD 2 X 4 DF No.1 &Btr BOT CHORD 2 X 4 DF No.1 &Btr WEBS 2 X 4 DF Stud/Std *Except* W2 2 X 4 DF No.1 &Btr, W3 2 X 4 DF No.1 &Btr W4 2 X 4 DF No.1 &Btr DEFL in (loc) I/defl Ud PLATES GRIP Vert(LL) -0.09 9-10 >999 360 MT20 2201195 Vert(TL) -0.17 9-10 >999 180 Horz(TL) 0.06 7 n/a n/a Weight: 158 lb BRACING TOP CHORD Structural wood sheathing directly applied or 3-9-15 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 4-12, 1-14 REACTIONS (lb/size) 14=1406/0-3-8, 7=1570/0-5-8 Max Horz 14=-246(load case 3) Max Uplift14=-248(load case 5), 7=-383(load case 6) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-1 144/259,2-3=-1250/348, 3-4=-1269/329, 4-5=-1797/412, 5-6=-1908/394, 6-7=-2551/483, 7-8=0/59, 1-14=-1357/271 BOT CHORD 13-14=-44/219, 12-13=-98/939, 11-12=-146/1607, 10-11=-146/1607, 9-10=-307/2155, 7-9=-307/2155 WEBS 2-13=-610/153, 2-12=-86/291, 3-12=-143/571, 4-12=-849/286, 4-10=-46/395, 6-10=-630/210, 6-9=0/226, 1-13=-170/1121 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 90mph; h=25ft; TCDL=4.Opsf; BCDL=4.8psfi Category !I; Exp C; enclosed; MWFRS gable end zone; cantilever left and right exposed; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) This truss requires plate inspection per the Tooth Count Method when this truss is chosen for quality assurance inspection. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 248 lb uplift at joint 14 and 383 lb uplift at joint 7. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1. LOAD CASE(S) Standard JUL? 1 cuss Tr - Type Qty Ply — 0129KH IC4 lkwOF TRUSS 11 1 6.400 s Jan 31 07:29:50 2007 Page 1 5-9-3 11-2-14 16-11-15 22-8-15 29-0-8 30-6-8 5-9-3 5-5-11 5-9-1 5-9-1 6-3-9 1-6-0 4x6 = Scale = 1 6.00 12 3 14 13 12 11 10 g 4X6 = 2x4 11 3x5 = 4x8 = 3x5 = 2x4 11 3x5 = 5-9-3 5-9-3 11-2-14 16-11-15 5-5-11 5-9-1 22-8-15 5-9-1 29-0-8 6-3-9 LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud PLATES GRIP TCLL 35.0 Plates Increase 1.15 TC 0.92 Vert(LL) -0.10 9-10 >999 360 MT20 220/195 TCDL 8.0 Lumber Increase 1.15 BC 0.42 Vert(TL) -0.18 9-10 >999 180 BCLL 0.0 Rep Stress Incr YES WB 0.53 Horz(TL) 0.06 7 n/a n/a BCDL 8.0 Code 1RC2003/TPI2002 (Matrix) Weight: 160 lb LUMBER TOP CHORD 2 X 4 DF No. 1&Btr BOT CHORD 2 X 4 DF No. 1&Btr WEBS 2 X 4 DF Stud/Std *Except* W2 2 X 4 DF No.1 &Btr, W3 2 X 4 DF No.1 &Btr W4 2 X 4 DF No.1 &Btr, EV1 2 X 4 DF Stud REACTIONS (lb/size) 14=1457/0-5-8, 7=1621/0-5-8 Max Horz 14=-231(load case 3) Max Upliftl4=-262(load case 5), 7=-392(load case 6) BRACING TOP CHORD Structural wood sheathing directly applied or 3-8-14 oc purlins, except end verticals. BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. WEBS 1 Row at midpt 2-12. 4-12 FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-2=-1333/281, 2-3=-1376/367, 3-4=-1382/349, 4-5=-1906/432, 5-6=-2019/414, 6-7=-2660/503, 7-8=0/59, 1-14=-1404/285 BOT CHORD 13-14=-54/206, 12-13=-139/1101, 11-12=-165/1705, 10-11=-165/1705, 9-10=-325/2252, 7-9=-325/2252 WEBS 2-13=-547/150, 2-12=-161/233, 3-12=-157/653, 4-12=-848/285, 4-10=-46/393, 6-10=-629/210, 6-9=0/226, 1-13=-179/1207 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 90mph; h=25ft; TCDL=4.Opsf, BCDL=4.8pst, Category II; Exp C; enclosed; MWFRS gable end zone; cantilever left and right exposed; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33. 3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 4) This truss requires plate inspection per the Tooth Count Method when this truss is chosen for quality assurance inspection. 5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 262 lb uplift at joint 14 and 392 lb uplift at joint 7. 6) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSVI-PI 1. LOAD CASE(S) Standard Job Truss T Type Qty Ply 10129KH C5 ALE 1 1 � Job Reference (optional) FRANKLIN BUILDING SUPPLY, JEROME, ID. 83338 6.400 s Aug 12006 MTek Industries, Inc. Wed Jan 31 07:29:51 2007 Page 1 11-2-14 29-0-8 , 11-2-14 17-9-10 Scale = 1:53.5 3x5 = 7 6.00 F12 6 8 5 9 4 10 3 11 2 S72 S77 12 'S73 8 ' 1 74 9 13 3x5 5 S 0 ST 1 14 15 1 Stu 16 S 17 -o CS 31 30 29 28 27 26 25 24 23 22 21 20 19 18 3x5 5x6 = 29-0-8 J r 29-0-8 Plate Offsets MY): : 7:0-2-8 Ede 23:0-3-0 0-3-0 LOADING (psf) SPACING 2-0-0 CSI DEFL in floc) I/detl Ud PLATES GRIP TCLL 35.0 Plates Increase 1.15 TC 0.16 Vert(LL) n/a - n/a 999 MT20 220/195 TCDL 8.0 Lumber Increase 1.15 BC 0.05 Vert(TL) n/a - n/a 999 BCLL 0.0 Rep Stress Incr NO WB 0.16 Horz(TL) 0.01 17 n1a n/a BCDL 8.0 Code IRC2003/TP12002 (Matrix) Weight: 175 lb LUMBER BRACING TOP CHORD 2 X 4 DF No.1 &Btr TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, BOT CHORD 2 X 4 DF No.1 &Btr except end verticals. WEBS 2 X 4 DF Stud/Std BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing. OTHERS 2 X 4 DF Stud/Std "Except* WEBS 1 Row at midpt 6-26, 8-25 ST2 2 X 4 DF No.1 &Btr, ST7 2 X 4 DF No.1 &Btr REACTIONS (lb/size) 31=110/29-0-8, 26=187/29-0-8, 27=206/29-0-8, 28=205/29-0-8, 29=199/29-0-8, 30=225/29-0-8, 25=188/29-0-8. 24=204/29-0-8, 23=203129-0-8, 22=206/29-0-8, 21=203/29-0-8, 20=208/29-0-8, 19=188/29-0-8, 18=256/29-0-8, 17=102/29-0-8 Max Horz 31 =-203(load case 3) Max Uplift31=-35(load case 6), 27=-89(load case 5), 28=-69(load case 5), 29=-61(load case 5), 30=-100(load case 5), 24=-85(load case 6), 23=-67(load case 6), 22=-68(load case 6), 21=-69(load case 6), 20=-70(load case 6), 19=-64(load case 6), 18=-87(load case 6), 17=-28(load case 4) Max Grav31=110(load case 1), 26=187(load case 1), 27=209(load case 9), 28=205(load case 1), 29=199(load case 1) , 30=226(load case 9), 25=188(load case 1), 24=206(load case 10), 23=203(load case 1), 22=206(load case 10), 21=203(load case 1), 20=208(load case 1), 19=188(load case 1), 18=256(load case 10), 17=102(load case 1) FORCES (lb) - Maximum Compression/Maximum Tension TOP CHORD 1-31=-91/54, 1-2=-48/61, 2-3=-50/107, 3-4=-48/152, 4-5=-48/198, 5-6=49/253, 6-7=-42/228, 7-8=42/230, 8-9=-49/266, 9-10=-48/225, 10-11=-52/195, 11-12=-60/163, 12-13=-89/130, 13-14=-117/108, 14-15=-139/94, 15-16=-145/88, 16-17=-177/80 BOT CHORD 30-31=-60/171, 29-30=-60/171, 28-29=-60/171, 27-28=-60/171, 26-27=-60/171, 25-26=-60/171, 24-25=-60/171, 23-24=-60/171, 22-23=-60/169, 21-22=-60/169, 20-21=-60/169, 19-20=-60/169, 18-19=-60/169, 17-18=-60/169 WEBS 6-26=-157/0, 5-27=-176/108, 4-28=-173/86, 3-29=-167/85, 2-30=-193/102, 8-25=-157/15, 9-24=-176/103, 10-23=-171/86, 11-22=-172/88, 12-21=-172/88, 13-20=-174/89, 14-19=-163/85, 16-18=-202/100 NOTES 1) Unbalanced roof live loads have been considered for this design. 2) Wind: ASCE 7-02; 90mph; h=25ft; TCDL=4.0psf; BCDL=4.8psf; Category II; Exp C; enclosed; MWFRS gable end zone; cantilever left and right exposed; end vertical left and right exposed; Lumber DOL=1.33 plate grip DOL=1.33. 3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see MiTek "Standard Gable End Detail" 4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads. 5) All plates are 2x4 MT20 unless otherwise indicated. 6) This truss requires plate inspection per the Tooth Count Method when this truss is chosen for quality assurance inspection. 7) Gable requires continuous bottom chord bearing. 8) Gable studs spaced at 2-0-0 oc. Continued on page 2 Job Truss Tr Type Qty Ply 0129KH C5 C§I�dLE 1 1 �✓ Job Reference o tonal FRANKLIN BUILDING SUPPLY, JEROME, ID. 83338 6.400 s Aug 12006 MiTek Industries, Inc. Wed Jan 31 07:29:51 2007 Page 2 NOTES 9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 35 lb uplift at joint 31, 89 lb uplift at joint 27, 69 lb uplift at joint 28, 61 lb uplift at joint 29, 100 lb uplift at joint 30, 85 lb uplift at joint 24, 67 lb uplift at joint 23, 68 lb uplift at joint 22, 69 lb uplift at joint 21, 70 lb uplift at joint 20, 64 lb uplift at joint 19, 87 lb uplift at joint 18 and 28 lb uplift at joint 17. 10) This truss is designed in accordance with the 2003 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSIITPI 1. LOAD CASE(S) Standard