HomeMy WebLinkAboutSTRUCTURAL CALCS - 07-00080 - 354 Oaktrail Dr - New SFROn For: Plan #: Location: From: Structural Calculations Kartchner Homes Newport B Lot #31, Oakbrook Rexburg William 2329 W. Morgan, Design Criteria IRC Roof Load; Live Load (F Dead Load ( Floor Load; Live Load (F Dead Load (. L.C. Road (801) 876-3501 Seismic Zone: D1 Wind Speed: 90 mph (110 mph 3 second gust) 22 Jan 2007 0700080 3 9 Oaktrail Dr-Kartchner Exposure: C Material Properties & Assumptions Concrete PSI (fc'): 3000 (found.), 3000 (slabs), 4000 (susp. slabs) Concrete Reinforcement: ASTM A615 Grade 60 Site Conditions: Dry & Stable granular based, 1500 PSF Bearing Capacity, Granular Based Backfill (KH=35 pcf, KP=225), Slope not to exceed 20%, Minimum setback from slopes of 25' Dimensional Lumber: Hem or Doug Fir #2 & BTR Steel: ASTM A36 Use Simpson straps and tie downs, and meet nailing, reinforcement and other structural requirements as noted on the drawing and within the pages of this document. These structural calculations are based on conditions and assumptions listed above. If the conditions listed herein are not met or are different it shall be brought to the attention of the engineer. Roof Truss and beam system to be engineered by the supplier. This engineering assumes that the building site is dry and stable, a high water table or adverse soils such as plastic clays, fills etc. could cause future flooding, settlement, site instability, or other adverse conditions. Verification of and liability for the soil bearing pressure, site stability, and all other site conditions, including site engineering as required, is the responsibility of others. These calculations and engineering are for the new building structure only and do not provide any engineering analysis of or liability/warranty for the non-structural portions of the building, or the site itself. William York is the structural engineer only and does not assume the role of "Registered Design Professional" on this project. The purpose of these calculations and engineering is to help reduce structural damage and loss of life due to seismic activity and/or high wind conditi c verify all conditions, dimensions and structural details of the drawing. t s—� TIE calculations is not permitted. n I FEB 22 6 2007 CITY OF POEXE"UR0 'I ` 0 All exterior walls shall be sheathed with 7/16" APA rated structural wood panel. Block all horizontal edges 1 V2" nominal or wider. Sheathing shall extend continuous from floor to top plate and be nailed at least 4" O.C. along sill plate. Extend sheathing over gable end to wall joints & over rim joist between floors and nail to rim and wall plates 6" O.C. Shear Wall Schedule type Sheathing Nail Edge Field Anchor Bolts Typical 7/16" one side 8d 6" O.C. 10" O.C. %2" 32" O.C. SW-1 7/16" one side 8d 4" O.C. 10" O.C. Y2" 32" O.C. Staples may be used in place of 8d nails at Y2 the spacing The following general requirements shall be followed during construction: 1. Contractor to verify all dimensions, spans, & conditions and notify engineer of any errors, omissions, or discrepancies prior to construction. 2. Use Simpson A35 ties each cantilevered joist to sill or top plate. 3. Use Simpson H1 or equiv. ties each end of each truss. 5. Foundation reinforcement as per Utah State Amendment 6. Use 2: #4 bars continuous for all footings 2: # 4 bars each side of openings & 2 # 4 bars top & bottom extend 36" beyond opening lk 8. Use Y2" x 10" J bolts 32" O.C. all foundation walls 9. If discrepancies are found, the more stringent specification shall be followed. 10. All multiple beams and headers to be nailed using 16d two rows 12" O.C. 11. Contractor shall assure that all materials are used per manufactures recommendations. 12. Geotech engineer shall verify overall global stability of the building site. Q 13. Connect beams & headers over 6 ft., to trimmers with appropriate connectors/hangers. 14. Contractor shall assure that footings are properly drained and that soil is dry and that footings rest on undisturbed native soil 30" below finished grade and that building horizontal clearance from footings to adjacent slopes be a minimum of 25 feet and that the intent of IRC section R403.1.7.2 is met. If set back requirements of R403.1.7.2 can not be met then contact engineer for further design requirements. 15. The contractor shall conform with all building codes and practices as per the 2003 IRC. 16. Use balloon framing method when connecting floors in split level designs. '; 17. Nail all shear walls to floor joist using 2: 16d 16" O.C. Add additional floor joist as reqd. 18. Provide joist and rafter hangers as per manufacturers specifications. 19. Foundation steps shall not excbed 4 feet or Y2 the horizontal distance between steps. Horz. rebar shall be 12" O.C. through step downs and extend 48" either side of step 20.If garage return walls are less than 32" wide then extend headers across return walls with 2 king studs on either end extending from the top of the header to the bottom plate or install (2) MST 36 straps each end of header extend across wing walls. 21. Use a minimum of 2-9 Y2" LVLs for all headers carrying girder loads. 22. Allow foundation 14 days to cure prior to backfill 23. Use 1 1/8" wide timberstrand or equiv. for all rim joist 24. Provide solid blocking through structure down to footing for all load paths. 25. Builder shall follow all recommendations found in all applicable Geotechnical reports. 26. Stacking of two sill plates is permitted with 5/8" J-bolts through both plates. Stacking more than two plates is not permitted without special engineering BCI JOISTS Span (ft) Depth Load Parameters Floor Dead Load Floor Live Load Total Floor Load Plan: N,port B Date: 22 Jan 2007 Location: Lot #31, Oakbrook 6000 1.7E 12 11.88 Simple Span Joist Duration Increase Joist Span(ft) Joist Spacing Joist Weight (plf) Joist Loading (plf) Max Reaction (Ibs) Max Moment (FtLb/If) Max Shear Lb Determine Joist Size Depth = Max Moment 100% (ft-Ibs) _ F. S. for moment = Max Shear 100% (Ibs) _ F. S. for shear = Bearing Required (in.)= Live Load (L/360) = Total Load (L/240) _ El x 10^6 (lb-inA2) K x 10^6 (Ibs) Live Load Deflection (in) Total Load Deflection (in) Live Load F of S Total Load F of S 10 40 50 1 12 19.2 2.5 83 495 1485 495 11 7/8" 3670 2.47 1675 3.38 2.00 0.40 0.60 305 6 0.12 0.15 3.44 4.00 6000 1.7E 19 11.88 10 40 50 1 19 16 2.5 69 657 3121 657 11 7/8" 3670 1.18 1675 2.55 2.00 0.63 0.95 305 6 0.55 0.71 1.15 1.33 Selection 11 7/8" 6000 1.7E @ 19.2" 11 718" 6000 1.7E @ 16" Plan: Newport B • Date: 22 Jan 2007 L41111V Location: Lot931, Oakbrook Wind Loading Calculations using Main Windforce-Resisting System (MWFRS) Transverse Direction Wind Design Coefficients P=wind load«exp coeff'Iw P=Design Pressure Horizontal Wind Load (from table 1609.6.2.1(1) Wall Load (psf)= end zone (A) 16.1 interior zone (C) 11.7 Roof Load (psf)= end zone (B) 2.6 interior zone (D) 2.7 Vertical Wind Load (from table 1609.6.2.1(1) Roof Load (psf)= end zone windward (E) -7.2 end zone leeward (F) -9.8 interior zone windward (G) -5.2 interior zone leeward (H) -5.2 Exposure Coefficient (from table 1609.6.2.1(4) 1.21 iw=Importance Factor (from table 1604.5) 1.0 Wind Speed = 90 Roof Height 11.75 Exposure C Wall Height 15 Truss Span 47 Roof Slope = 6 /12 Roof Angle (deg)= 26.56 Sine = 0.4472 Minimum Pressure P=wind load«exp coeff«Iw Adjusted horizontal wall interior 14.16 14.16 horizontal wall end zone 19.48 19.48 horizontal roof interior 3.27 10.00 horizontal roof end zone 3.15 10.00 vertical end zone windward -8.71 0.00 vertical end zone leeward -11.86 0.00 vertical interior zone windward -6.29 0.00 vertical interior zone leeward -6.29 0.00 End Zone Width (ft) 4.1 32.8 Gable Roof Load Width 4.1 32.8 Hlp Roof Load Wall Load End Interior End Interior End Interior Area 481.75 116.44 Width 4.1 32.8 Vertical Force Width end zone windward 4 leeward 4 interior zone windward 33 leeward 33 Floor 2 Diaphragm Shear Total Shear (Ibs) 5982 Left Wall Length 10 Right Wall Length 10 Floor 1 Diaphragm Shear Total Shear (Ibs) 11599 Left Wall Length 27 Right Wall Length 33 basement Diaphragm Shear Total Shear (Ibs) 15343 Lett Wall Length 24 Right Wall Length 24 Critical Wall Length (ft)= Left Wall Dead Load (plQ= 482 Left Wall Critical Length (ft)= 5 Right Wall Dead Load (plf)= 512 Right Wall Critical Length (ft)= 4 Calculate Uplift, Force Req'd to Prevent OT (Ibs) Panel Length (ft) 2 3 Front 898 703 Back 634 424 2nd storyEnd Zone Width (ft) 2nd Storylnterior Zone Width (ft) Height Wind Load Force (Ibs) 2.0 19.48 157 4.89 14.16 3185 Sum = 3341.68 10.00 4818 10.00 1164 Total 5982 Height Wind Load Force (Ibs) 1.0 19.48 160 1.00 14.16 464 Sum = 624.0938 length Wind Load Force (Ibs) 42.95 0.00 0 42.96 0.00 0 42.95 0.00 0 42.95 0.00 0 Shear Wall Loads (plf) Not Applicable Not Applicable Shear Wall Loads (plf) 215 176 Shear Wall Loads (plf) 320 320 4.1 32.8 4111111111101 2nd Story 464.35 Total 18632 Total (plf) 92 4 6 8 10 12 507 117 -274 -664 -1055 213 -207 -628 -1049 -1469 Plan: Newport B Date: 22 Jan 2007 Location: Lot #31, Oakbrook WIfid Loading Calculations using Main Windforce-Resisting System (MWFRS) Longitudinal Direction Wind Design coefficients P=wind loadfexp coeff lw P=Design Pressure Horizontal Wind Load (from table 1609.6.2.1(1) Wall Load (psf)= end zone (A) 16.1 interior zone (C) 11.7 Roof Load (psf)= end zone (B) 2.6 interior zone (D) 2.7 Vertical Wind Load (from table 1609.6.2.1(1) Roof Load (psf)= end zone windward (E) -7.2 end zone leeward (F) -9.8 interior zone windward (G) -5.2 interior zone leeward (H) -5.2 Exposure Coefficient (from table 1609.6.2.1(4) 1.21 Iw=Importance Factor (from table 1604.5) 1.0 Wind Speed = s0 Roof Height 11.75 Exposure C Wall Height 15 Truss Span 47 Roof Slope a 6 /12 Roof Angle (deg)= 26.56 Sine = 0.4472 Minimum Pressure P=wind loadfexp coeff'iw Adjusted horizontal wail Interior 14.16 14.16 horizontal wail end zone 19.48 19.48 horizontal roof interior 3.27 10.00 horizontal roof end zone 3.15 10.00 vertical end zone windward -8.71 0.00 vertical end zone leeward -11.86 0.00 vertical interior zone windward -6.29 0.00 vertical interior zone leeward -6.29 0.00 .4fHmean 8.35 .lfbase 4.1 End Zone Width (ft) 4.1 Interior Zone Width (ft) 41.8 Gable Roof Load Width 4.1 41.8 End I nterior Hip Roof Load End Interior Area 587.5 148.39 Wall Load Width End 4.1 Interior 41.8 Vertical Force Width end zone windward 4 leeward 4 interior zone windward 42 leeward 42 Floor 2 Diaphragm Shear Total Shear (Ibs) 7359 Front Wall Length 10 Back Wall Length 10 Floor 1 Diaphragm Shear Total Shear (Ibs) 14122 Front Wall Length 25 Back Wall Length 37 basement Diaphragm Shear Total Shear (Ibs) 18632 Front Wall Length 32 Back Wall Length 30 Critical Wall Length (ft)= Front Wall Dead Load (plf)= 1074 Front Wall Critical Length (ft)= 3 Back Wall Dead Load (plf)= 1074 Back Wail Critical Length (ft)= 2 Calculate Uplift, Force Req'd to Prevent OT (Ibs) Panel Length (ft) 2 3 Front 705 211 Back 156 -339 2nd storyEnd Zone Width (ft) 2nd Storylnterior Zone Width (ft) Height Wind Load Force (Ibs) 2.0 19.48 157 4.89 14.16 4058 Sum = 4215.507 Wind Load Force (Ibs) 10.00 5875 10.00 1484 Total 7359 Height Wind Load Force (lb/ft) 1.0 19.48 160 1.00 14.16 592 Sum = 751.5068 length Wind Load Force ((bs) 18.45 0.00 0 18.45 0.00 0 18.45 0.00 0 18.45 0.00 0 Shear Wall Loads (plf) Not Applicable Not Applicable Shear Wall Loads (plf) 282 191 Shear Wail Loads (pif) 291 311 Total 15343 Total (plf) 84 4.1 41.8 2nd Story Force (111M) ►f lffffff ffffffNf fNffff ff 4 6 8 10 12 -284 -1273 -2262 -3252 -4241 -834 -1823 -2812 -3801 -4791 Plan: Newport B ' Date: 22 Jan 2007 14� Location: Lot #31, Oakbrook Sei§mic Calculations Loading Summary Floor Dead Load (psf) 10 Seismic Zone E Floor Live Load(psf) 40 Walls (Ext)(psf) 20 Roof LL(psf) 50 Walls (Int)(psf) 10 Roof Dead Load(psf) 15 Roof Slope 6 /12 Exterior combination Snow Load Reduction Seismic Parameters Slope 26.56 V=Cs'W/1.4 Snow 50.00 Fa= 1 Pitch over 20 R= 6 table 1617.6 Rs Ss= 1.772 Reduction Sms= 1.77 eq. 16-16 L.L.- Reduction 50.00 Sds= 1.18 eq 16-18 Total Load 65.00 Cs= 0.236 per eq. 1649 Adj. Factor 1.4 Cs= 0.1686 Roof Length W(psf) Lb/ft Width W(lb) 41 25 1025 50 51250 roof wall 8190 Total Mass Tributary to Roof Levels = 59440 Shear (V)(lbs) Roof Levels = 10021 Floor 2 Length W(psf) lb/ft Width W(lb) 41 10 410 50 0 wall height 0 8190 Total Mass Tributary to Floor 2= 0 Shear (V)(lbs) Floor Levels = 0 Floor 1 Length W(psf) Ibfft Width W(lb) 41 10 410 50 13820 wall height 9 19110 Total Mass Tributary to Floor 1= 32930 Shear (V)(lbs) Floor Levels = 5552 Floor 1 Lateral Force 5552 Floor 2 Lateral Force 0 Roof Lateral Force 10021 Total Seismic Mass = 92370 Total Lateral Force = 15573 Seismic Force Distribution "' Roof Sections "' H(x) W(x) kip W(x)H(x) % Force Total Sheer Force (Kip) Roof 20.9 59 1241 86.26% 13.4338186 Floor 1 6.0 33 198 13.74% 15.5729486 Floor 2 0.0 0 0 0.00% 13.4338186 Totals 92 1438 1 V/sum(Wi•Hi) = 0.01083 Total Shear (Ibs) = 15573 Basement Sheer Wall F(total) Length Total Load (kips) 15.6 Shear Wall Load (plf) right side 7.8 24 324 left side 7.8 24 324 front 7.8 32 243 back 7.8 30 260 Floor 1 Sheer Wall F(total) Length Total Load (kips) 13.4 Shear Wall Load (plf) right side 6.7 33 204 left side 6.7 27 249 front 6.7 25 269 back 6.7 37 182 Floor 2 Sheer Wall F(total) Length Total Load (kips) 13.4 Shear Wall Load (plf) right side 6.7 10 Not Applicable left side 6.7 10 Not Applicable front 6.7 10 Not Applicable back 6.7 10 Not Applicable Shear Wall Critical Length! Wall DL Floor DL Roof DL DL (plf) critical I (ft) Front 320 50 1242 1074 5 Back 320 50 1242 1074 3 Right 240 475 54 512 7 Left 320 350 54 482 9 Calculate Uplift, Force Req'd to Prevent OT (Ibs) Panel Length (ft) 2 3 4 6 8 10 12 Front 2689 1615 542 -1605 -3753 -5900 -8047 Back 1121 47 -1027 -3174 -5321 -7468 -9615 Right 2639 2127 1615 591 -433 -1458 -2482 Left 3514 3031 2549 1585 620 -344 -1308 Plan: [,gwmport B Date: 22 Jan 2007 Location: Lot #31, Oakbrook LVL Beam RB-1 RB-2 Load Parameters Floor LL (psf) Total Floor Load(psf) Floor Span (ft) Total Floor Load (plf) Wall Height (ft) Wall Weight (psf) Wall Load (plf) Roof LL (psf) Total Roof Load (psf) Roof Span (ft) Roof Load (plf) Beam Weight (plf) Live Load (plf) Total Load (plf) Reactions & Moment Duration Increase Beam Span(ft) Reaction 1 (lb) Reaction 2 (lb) Max Moment FtLb Max Shear Lb Max Shear Stress (psi) Determine Size Depth Estimate (in) Width Estimate (in) Cross Area (in A2) Allowable Bending Stress = Allowable Moment = Momemt of Inertia I = Factor Of Safety = Allowable Sheer Stress (psi)= Allowable Sheer Force (lb)= Factor Of Safety = Bearing Required = E (psi) Deflection LL (in) LLoad Def. Limit U Allowable Deflection (in) LL Deflection F/S Deflection TL (in) TLoad Def. Limit U Allowable Deflection (in) TL Deflection F/S Selection RB-3 RB-5 RB-5 OPT 40 40 40 40 40 50 50 50 50 50 0 0 0 0 0 0 0 0 0 0 7 0 0 0 0 35 20 20 20 20 245 0 0 0 0 30 50 50 50 50 45 65 65 65 65 2 8 22 40 40 45 260 715 1300 1300 12.1 10 10 18 14 30 200 550 1000 1000 302 270 725 1318 1314 1.15 1 1 1 1 16 12 5 12 12 2416 1618 1812 7909 7885 2416 1618 1812 7909 7885 9666 4854 2265 23726 23656 2416 1618 1812 7909 7885 58 49 54 127 161 11.88 9.50 9.50 11.88 14.00 3.5 3.5 3.5 5.3 3.5 42 33 33 62 49 2994 2684 2684 2604 2546 20542 11775 11775 26793 24258 489 250 250 734 800 2.13 2.43 5.20 1.13 1.03 328 285 285 285 285 9085 6318 6318 11850 9310 3.76 3.90 3.49 1.50 1.18 0.92 0.62 0.69 2.01 3.00 1900000 1900000 1900000 1900000 1900000 0.05 0.20 0.02 0.33 0.31 360 360 360 360 360 0.53 0.40 0.17 0.40 0.40 11.20 2.04 10.24 1.19 1.30 0.48 0.26 0.02 0.44 0.40 240 240 240 240 240 0.80 0.60 0.25 0.60 0.60 1.67 2.27 11.66 1.36 1.49 2: 11 7/8" 2: 9 Y2" 2: 9 Y2" 3: 11 7/8" 2: 14" Plan: N -port B *,, Date: 2 an 2007 Location: Lot #31, Oakbrook Exterior Footing Calculations back front left right Concrete Specs Density (pcf) 150 150 150 150 Strength (psi) 3000 3000 3000 3000 Clear Cover Thickness (in) 3 3 3 3 Foundation Overall Height (ft) 4.67 4.67 4.67 4.67 Height (in) 56 56 56 56 Wall Thickness (ft) 0.67 0.67 0.67 0.67 Thickness (in) 8 8 8 8 Weight (kips/Ift) 0.47 0.47 0.47 0.47 Footing Specs Width (ft) 1.67 1.67 1.67 1.67 Width (in) 20 20 20 20 Height (ft) 0.83 0.83 0.83 0.83 Height (in) 10 10 10 10 Weight (kips/Ift) 0.21 0.21 0.21 0.21 Area per Ift 1.67 1.67 1.67 1.67 Soil Specs Density (pcf) 125 125 125 125 Soil Pressure (psf) 1500 1500 1500 1500 Weight (kips/Ift) 0.29 0.29 0.29 0.29 Building Loads Roof span 46 46 2 2 Roof (kips/Ift) 1.24 1.24 0.05 0.05 Wall Height (ft) 16 16 16 12 Wall Load (kips/Ift) 0.32 0.32 0.32 0.24 Floor span 2 2 19 14 Floor Loads (kips/Ift) 0.05 0.05 0.48 0.35 Total (kips.ift) 1.61 1.61 0.85 0.64 Calculations Total Weight on Soil (kips) 2.29 2.29 1.52 1.32 Soil Load (ksf) 1.37 1.37 0.91 0.79 Required Footing Width (in) 20 20 20 20 Required Footing Depth (in) 10 10 10 10 Plan: Newp B Date: 22 Jan 1007 Location: Lot #31, Oakbrook Sawn Lumber FB-1 FB-2 RB-4 Load Parameters Floor Live Load(psf) 40 60 40 Floor Total Load(psf) 50 70 50 Floor 1 Span(ft) 27 10 0 Total Floor Load(plf) 675 350 0 Wall Height (ft) 0 0 0 Wall Weight (psf) 20 20 20 Wall Load(plf) 0 0 0 Roof LL (psf) 50 50 50 Total Roof Load(psf) 65 65 65 Roof Span(ft) 0 0 47 Total Roof Load(plf) 0 0 1528 Beam Weight (plf) 5.1 8.3 6.5 Live Load (plf) 540 300 1175 Total Load (plf) 680 358 1534 Reactions & Moment Duration Increase 1 1 1 Beam Span(ft) 4 10 4 Reaction 1 (lb) 1360 1792 3068 Reaction 2 (lb) 1360 1792 3068 Max Moment FtLb 1360 4479 3068 Max Shear Lb 1360 1792 3068 Determine Beam Size Depth Estimate (in) 7.25 9.25 9.25 Width Estimate (in) 3.5 4.5 3.5 CF = 1.30 1.20 1.20 Area = 25.38 41.63 32.38 Momemt of Inertia I = 111 297 231 Maximum Bend Stress = 532 838 738 Allowable bend Stress 1105 1020 1020 Factor Of Safety = 2.08 1.22 1.38 Allowable Sheer Stress 195 180 180 Max Shear Cap (Ibs) = 3299 4995 3885 Factor Of Safety = 2.43 2.79 1.27 Bearing Required = 0.96 0.98 2.16 E (psi) 1300000 1300000 1300000 Deflection LL (in) 0.02 0.17 0.02 I -Load Def. Limit U 360 360 360 Allowable Deflection (in) 0.13 0.33 0.13 LL Deflection F/S 6.19 1.91 5.91 Deflection TL (in) 0.03 0.21 0.03 TLoad Def. Limit U 240 240 240 Allowable Deflection (in) 0.2 0.5 0.2 TL Deflection F/S 7.38 2.39 6.79 hrr` Selection 2: 2 x 8 3: 2 x 10 2: 2 x 10 �J Sheer wall lines (three sheer wall lines) Dimentlons D1= 15ft D2 = 28 ft Length = 43 ft Total Sheer Seismic 13434 lb Wind 14112 lb Sheer Wall line loads Hem Fir Reduction 0.95 Wind Increase 1.4 Line T1 Tributalry Area Seismic Vseismic Resistence Sheer Wail SW-1 SW-1 SW-1 SW-5 Portal Frame Wind VWind = Resistence Sheer Wall Portal Frame 0.17 Total Area 2343 lb LENGTH Length per Height per Resistence length Total annel ft annel ftper foot(lb) ft Resistence Ib 3 9 241 6 1444 2.6666 9 214 10.6666 2282 3 9 241 0 0 4 9 414 0 0 Length per Height per Resistence number Total annel 11 annel ftper pannel(lb) of pannels Resistence Ib 2 8 1615 0 0 Sum = 3726 Factor of Safety 1.59 2461 lb Length per Height per Resistence length Total annel ft annel ft r foot(lb) 11 Resistence(lb) 3 9 505 6 3032 2.6666 9 505 10.6666 5391 3 9 505 0 0 4 9 652 0 0 Length per Height per Resistence number Total annel ft annel per pannel(lb) of pannels Resistence(lb) 2 8 1615 0 0 Sum = 8423 Factor of Safety 3.42 r� 77 Line T2 Tributalry Area 0.50 Total Area Seismic Vseismic = 6717 lb Resistence Sheer Wall Length per Height per Resistence length Total annel fl annel ftper foot(lb) ft Resistence(lb) SW-1 5 9 361 20 7220 SW-1 5 9 361 0 0 SW-1 5 9 361 0 0 SW-5 5 9 466 0 0 Length per Height per Resistence number Total annel ft annel ftper pannel(lb) of pannels Resistence Ib Portal Frame 1.3 10 570 0 0 Sum = 7220 Factor of Safety 1.07 Wind VWnd = 7056 lb Resistence Sheer Wall Length per Height per Resistence length Total annel ft annel ftper foot(lb) ft Resistence(lb) SW-1 5 9 505 20 10108 SW-1 5 9 505 0 0 SW-1 5 9 505 0 0 SW-5 5 9 652 0 0 Length per Height per Resistence number Total annel ft annel ft r pannel(lb) of pannels Resistence(lb) Portal Frame 1.3 10 570 0 0 Sum = 10108 Factor of Safety 1.43 Line T3 Tributalry Area 0.33 Total Area Seismic Vseismic = 4374 lb Resistence Sheer Wall Length per Height per Resistence length Total annel ft annel ftper foot(lb) ft Resistence(lb) SW-1 5 9 361 16 5776 SW-1 3.5 9 281 7 1965 SW-1 4 9 321 0 0 SW-5 4 9 414 0 0 Length per Height per Resistence number Total annel ft annel ftper pannel(lb) of pannels Resistence lb Portal Frame 1.3 10 570 0 0 Sum = 7741 Factor of Safety 1.77 Wind Wind = 4595 lb Resistence Sheer Wall Length per Height per Resistence length Total annel ft annel ftper foot(lb) ft Resistence Ib SW-1 5 9 505 16 8086 SW-1 3.5 9 505 7 3538 SW-1 4 9 505 0 0 SW-5 4 9 652 0 0 Length per Height per Resistence number Total annel ft annel ftper pannel(lb) of pannels Resistence Ib Portal Frame 1.3 10 570 0 0 Sum = 11624 Factor of Safety 2.53