Loading...
HomeMy WebLinkAboutJOIST LAYOUT - 07-00080 - 354 Oaktrail Dr - New SFR� II IMPORTANT PLEASE READ AND SIGN I'I IE; A'CI ACC IED SI IEL'1- BEFORE TAKING POSSESION OF YOUR LAYOLT! READ BY INTIALS DATE Trus Joist rim board A3 NAILING REQUIREMENTS TJI® joists at bearings: Two 8d (2Y") box nails (1 each side), 1 Y2" minimum from end. Blocking panels, rim joist or rim board to bearing plate: TJh blocking panels or rim joist: 10d (3") box nails at 6" o.c. Thus Joist rim board: Toenail with 10d (3") box nails at 6" o.c. or 16d (3Y") box nails at 12" o.c. Shear transfer. Connections equivalent to decking nail schedule Rim board, rim joist or closure to TJI®'ol ist: 13/4" width or less: Two 10d (3") box nails, one each at top and bottom flange. 2%6" thru 2Yz" widths: Two 16d (3Y2") box nails, one each at top and bottom flange. 3Y2" width: Toenail joist to rim joist with one 10d (3") box nail each side of joist lop flange. 20 minimum squash blocks: Two 10d (3") box nails, one each at lop and bottom flange. DO NOT allow workers to walk on joists until braced. INJURY MAY RESULT. WARNING Joists are unstable until braced laterally Bracing Includes: • Blocking • Sheathing • Hangars • Rim Board • Slrul Grros • Rim Jo*t DO NOT stack building materials on unsheathed joists. Stack only over beams or walls. WARNING NOTES: Lack of concern for proper bracing during construction can result in serious accidents. Under normal conditions if the following guidelines are observed, accidents will be avoided. f. All blocking. hangers. him boards and rim fasts at We end supports of the TJI ` )oasts must be completely installed and pmpetly ❑ailed. 2. Lateral strength, Oka a braced end wall Oran existing deck, most be establishe At the ends of the bay This Can also be accomplished by a temporary or permanent deck ShesthirgV fastened to the first 4 lee1 of joists at the end of the bay. 3. Safety bracing lines of ix4 (minimum) must he ended to a husband end wall ed sheathed area as in note 2 and to each piss. Without this bracing, hishir" Sideways or rollover M highly probable under light construction loads - like a worker or one layer of unnabad sheathing. 4. Sheathing must be totally Btteched to Seen TJI s joist before additional bads can be placed on the system. b. ENS of canbtevers require safety bracing on both the top and bottom flanges. 6. The flanges must remain straight within a tolerance of K" from lose alignment. O gml �q d o ml 3 III in A3 ti O All Rml ,a O ku � W r - CITY OF REy �JTJXpert. �sas�avX JOIST AND DEAN LIST Plot In Length Product Plies Qty A See Layout 11 7/8" TJI 110 ioist 1 M1 5' 1 3./4" x 7 1/4" 1.9E Microllam LVL 2 6 ACCESSORIES LIST Pat 16' 1 1/4" x 11 7/8" 1.3E TimberStrand LSL 1 11 Shl 4' a 8' 23/32" Structurwood Edge Gold (24" Span Rating) 1 46 Rm, Rim Board LEVEL NOTES File Name: RGM-Hartchner Homes Job 178 050407.JOB Level Name: Main Floor Plotted: 5/4/2007 12.98 Design Sta this: Main Floor... 5/4/2007 12:33 NOTE: Level design times indicated above urovi assurance for proper level stacking, Design Methodology; ASD Floor Area Loading Is: 40ps£ Live Load and 12 psf Dead Load. Maximum Joist Deflection: L/480 Live Load L/240 Total Load TJ-Pro Rating Information: Weighted Averaae: 41 Lowest Rating: 29 H i ahest Rating: 56 Glued b Nailed Decking is Repaired Direct Floolied Ceiling is Not Reouired Floor Decking: 23/32" Structurwood Edge Gold (24" Span Rating) Normal O.C. Spacing = 19.2— 'Snless n,tod otherwise Scale: 1/4" = 1' CREATEC BY bmc west reabura 202 west main st. rexAuro ID 83440 206-716-0094 FAX: 208-356-3299 JOB COMMENTS RGM-Kartchner Homes Job 179 Rexburg, Idaho SYMBOL LEGEND O Point Load Line Load E- Area Load ODetail Callout Label (See Framer's Pocket Guide) 1 of 1 FOR THE TJ-XPERT WARRANTY SEE FRAMER'S POCKET GUIDE TJ-%pert 6.42 (it693) C6.42 D6.42 56.42 P6.42