Trus Joist
rim board
A3
NAILING REQUIREMENTS
TJI® joists at bearings: Two 8d (2Y") box nails (1 each side), 1 Y2"
minimum from end.
Blocking panels, rim joist or rim board to bearing plate:
TJh blocking panels or rim joist: 10d (3") box nails at 6" o.c.
Thus Joist rim board: Toenail with 10d (3") box nails at 6" o.c. or
16d (3Y") box nails at 12" o.c.
Shear transfer. Connections equivalent to decking nail schedule
Rim board, rim joist or closure to TJI®'ol ist:
13/4" width or less: Two 10d (3") box nails, one each at top and
bottom flange.
2%6" thru 2Yz" widths: Two 16d (3Y2") box nails, one each at top and
bottom flange.
3Y2" width: Toenail joist to rim joist with one 10d (3") box nail each
side of joist lop flange.
20 minimum squash blocks: Two 10d (3") box nails, one each
at lop and bottom flange.
DO NOT allow workers
to walk on joists
until braced.
INJURY MAY RESULT.
WARNING
Joists are unstable until braced laterally
Bracing Includes:
• Blocking • Sheathing
• Hangars • Rim Board
• Slrul Grros • Rim Jo*t
DO NOT stack building
materials on unsheathed
joists. Stack only over
beams or walls.
WARNING NOTES:
Lack of concern for proper bracing during construction can result in serious accidents.
Under normal conditions if the following guidelines are observed, accidents will be avoided.
f. All blocking. hangers. him boards and rim fasts at We end supports of the TJI ` )oasts must be completely installed and pmpetly ❑ailed.
2. Lateral strength, Oka a braced end wall Oran existing deck, most be establishe At the ends of the bay This Can also be accomplished
by a temporary or permanent deck ShesthirgV fastened to the first 4 lee1 of joists at the end of the bay.
3. Safety bracing lines of ix4 (minimum) must he ended to a husband end wall ed sheathed area as in note 2 and to each piss. Without this
bracing, hishir" Sideways or rollover M highly probable under light construction loads - like a worker or one layer of unnabad sheathing.
4. Sheathing must be totally Btteched to Seen TJI s joist before additional bads can be placed on the system.
b. ENS of canbtevers require safety bracing on both the top and bottom flanges.
6. The flanges must remain straight within a tolerance of K" from lose alignment.
O
gml
�q
d
o
ml
3
III
in
A3
ti
O All
Rml
,a
O
ku
�
W r -
CITY OF REy
�JTJXpert.
�sas�avX
JOIST AND DEAN LIST
Plot In
Length
Product
Plies
Qty
A
See Layout
11 7/8"
TJI 110 ioist
1
M1
5'
1 3./4"
x 7 1/4" 1.9E Microllam LVL
2
6
ACCESSORIES LIST
Pat
16'
1 1/4"
x 11 7/8" 1.3E TimberStrand LSL
1
11
Shl
4' a 8'
23/32"
Structurwood Edge Gold (24" Span Rating)
1
46
Rm, Rim
Board
LEVEL NOTES
File Name: RGM-Hartchner Homes Job 178 050407.JOB
Level Name: Main Floor
Plotted: 5/4/2007 12.98
Design Sta this:
Main Floor... 5/4/2007 12:33
NOTE: Level design times indicated above urovi
assurance for proper level stacking,
Design Methodology; ASD
Floor Area Loading Is:
40ps£ Live Load and 12 psf Dead Load.
Maximum Joist Deflection:
L/480 Live Load
L/240 Total Load
TJ-Pro Rating Information:
Weighted Averaae: 41
Lowest Rating: 29
H i ahest Rating: 56
Glued b Nailed Decking is Repaired
Direct Floolied Ceiling is Not Reouired
Floor Decking: 23/32" Structurwood Edge Gold (24"
Span Rating)
Normal O.C. Spacing = 19.2—
'Snless n,tod otherwise
Scale: 1/4" = 1'
CREATEC BY
bmc west reabura
202 west main st.
rexAuro ID 83440
206-716-0094
FAX: 208-356-3299
JOB COMMENTS
RGM-Kartchner Homes
Job 179
Rexburg, Idaho
SYMBOL LEGEND
O Point Load
Line Load
E- Area Load
ODetail Callout Label
(See Framer's Pocket Guide)
1 of 1
FOR THE TJ-XPERT WARRANTY
SEE FRAMER'S POCKET GUIDE
TJ-%pert 6.42 (it693) C6.42 D6.42 56.42 P6.42