HomeMy WebLinkAboutRESCHECK - 07-00080 - 354 Oaktrail Dr - New SFRe, 0700080 JAOaktrail Dr-Kartchner REScheck Software Version 3.7.3 Compliance Certificate Project Title: Oakbrook Lot 31, "Newport B Spec" Report Date: 01/24/07 Data filename: C:\Documents and Settings\Administrator\My Documents\BCI\REScheck\New\Idaho\Oakbrook 31 - newport.rck Energy Code: -; ?%Qoitcc Location: Rexburg, Idaho Construction Type: Single Family Glazing Area Percentage: 8% Heating Degree Days: 8693 Construction Site: Owner/Agent: Designer/Contractor: 309 Oaklrail Drive Kartchner Homes Rexburg, LIT` 601 W. 1700 S. Logan, UT 84321 435-755-7080 Jhoellein@kartchnerhomes.com Compliance: Passes Maximum UA: 343 Your Hams UA: 249 --= 27.4% Better Than Code ILIA) Ceiling 1: Flat Ceiling or Scissor Truss: 1384 40.0 0.0 40 Wall 1: Wood Frame, 16" o.c.: 1374 21.0 0.0 68 Window 1: Vinyl Frame:Double Pane: ill 0.350 39 Door 1: Solid: 55 0.200 11 Door 2: Glass: 18 0.350 6 Wall 2: Wood Frame, 16" o.c.: 445 21.0 0.0 22 Window 2: Vinyl Frame:Double Pane: 56 0.350 20 Wall 3: Solid Concrete or Masonry:Exterior Insulation: 483 12.0 0.0 43 Furnace 1: Forced Hot Air: 90 AFUE Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 20001ECC requirements in REScheck Version 3.7.3 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Solis Hrv7re Builder/Designer Company Name Dale M1111,11pi CITY OF REXBURG Oakbrook Lot 31, "Newport B Spec" Page 1 of 4 r4REScheck Software Version 3.7.3 Inspection Checklist Date: 01/24/07 Ceilings: ❑ Ceiling 1: Flat Ceiling or Scissor Truss, R-40.0 cavity insulation Comments: Above -Grade Walls: ❑ Wall 1: Wood Frame, 16" o.c., R-21.0 cavity insulation Comments: ❑ Wall 2: Wood Frame, 16" o.c., R-21.0 cavity insulation Comments: ❑ Wall 3: Solid Concrete or Masonry: Exterior Insulation, R-12.0 cavity insulation Comments: Windows: ❑ Window 1: Vinyl Frame:Double Pane, U-factor: 0.350 For windows without labeled U-factors, describe features: #Panes _ Frame Type Thermal Break? Yes _ No Comments: ❑ Window 2: Vinyl Frame:Double Pane, U-factor: 0.350 For windows without labeled U-factors, describe features: #Panes _ Frame Type Thermal Break? _ Yes _ No Comments: Doors: ❑ Door 1: Solid, U-factor: 0.200 Comments: ❑ Door 2: Glass, U-factor: 0.350 Comments: Heating and Cooling Equipment: ❑ Furnace 1: Forced Hot Air: 90 AFUE or higher Make and Model Number: Air Leakage: ❑ Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. ❑ Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials. If non -IC rated, the fixture must be installed with a 3" clearance from insulation. Vapor Retarder: ❑ Required on the warm -in -winter side of all non -vented framed ceilings, walls, and floors. Materials Identification: ❑ Materials and equipment must be installed in accordance with the manufacturer's installation instructions. ❑ Materials and equipment must be identified so that compliance can be determined. ❑ Manufacturer manuals for all installed heating and cooling equipment and service water healing equipment must be provided, ❑ Insulation R-values, glazing U-factors, and heating equipment efficiency must be clearly marked on the building plans or specifications. Oakbrook of 31, "Newport B Spec" Page 2 of 4 E5 Duct Insulation: ❑ Ducts in unconditioned spaces must be insulated to R-5. Ducts outside the building must be insulated to R-8.0. Duct Construction: ❑ All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric, or tapes. Tapes and mastics must be rated UL 181A or UL 181 B. Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). ❑ The HVAC system must provide a means for balancing air and water systems. Temperature Controls: ❑ Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each zone or floor shall be provided. Service Water Heating: ❑ Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. ❑ Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: ❑ Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: ❑ All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: ❑ HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F must be insulated to the levels in Table 2. Oakbrook Lot 31, "Newport B Spec" Page 3 of 4 Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes Insulation Thickness in Inches by Pipe Sizes Non -Circulating Runouts Circulating Mains and Runouts Heated Water Temperature ("F) Up to 1" Up to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes Fluid Temp. Insulation Thickness In Inches by Pipe Sizes Piping System Types Range(°F) 2" Runouts 1" and Less 1.25" to 2.0" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant and 40-55 0.5 0.5 0.75 1.0 Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD: (Building Department Use Only) Oakbrook Lot 31, "Newport B Spec" Page 4 of 4