REScheck Software Version 3.7.3
Compliance Certificate
Project Title: Oakbrook Lot 31, "Newport B Spec"
Report Date: 01/24/07
Data filename: C:\Documents and Settings\Administrator\My Documents\BCI\REScheck\New\Idaho\Oakbrook 31 - newport.rck
Energy Code: -; ?%Qoitcc
Location: Rexburg, Idaho
Construction Type: Single Family
Glazing Area Percentage: 8%
Heating Degree Days: 8693
Construction Site: Owner/Agent: Designer/Contractor:
309 Oaklrail Drive Kartchner Homes
Rexburg, LIT` 601 W. 1700 S.
Logan, UT 84321
435-755-7080
Jhoellein@kartchnerhomes.com
Compliance: Passes Maximum UA: 343 Your Hams UA: 249 --= 27.4% Better Than Code ILIA)
Ceiling 1: Flat Ceiling or Scissor Truss: 1384 40.0 0.0 40
Wall 1: Wood Frame, 16" o.c.: 1374 21.0 0.0 68
Window 1: Vinyl Frame:Double Pane: ill 0.350 39
Door 1: Solid: 55 0.200 11
Door 2: Glass: 18 0.350 6
Wall 2: Wood Frame, 16" o.c.: 445 21.0 0.0 22
Window 2: Vinyl Frame:Double Pane: 56 0.350 20
Wall 3: Solid Concrete or Masonry:Exterior Insulation: 483 12.0 0.0 43
Furnace 1: Forced Hot Air: 90 AFUE
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 20001ECC requirements in
REScheck Version 3.7.3 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
Solis Hrv7re
Builder/Designer Company Name Dale
M1111,11pi
CITY OF REXBURG
Oakbrook Lot 31, "Newport B Spec" Page 1 of 4
r4REScheck Software Version 3.7.3
Inspection Checklist
Date: 01/24/07
Ceilings:
❑ Ceiling 1: Flat Ceiling or Scissor Truss, R-40.0 cavity insulation
Comments:
Above -Grade Walls:
❑ Wall 1: Wood Frame, 16" o.c., R-21.0 cavity insulation
Comments:
❑ Wall 2: Wood Frame, 16" o.c., R-21.0 cavity insulation
Comments:
❑ Wall 3: Solid Concrete or Masonry: Exterior Insulation, R-12.0 cavity insulation
Comments:
Windows:
❑ Window 1: Vinyl Frame:Double Pane, U-factor: 0.350
For windows without labeled U-factors, describe features:
#Panes _ Frame Type Thermal Break? Yes _ No
Comments:
❑ Window 2: Vinyl Frame:Double Pane, U-factor: 0.350
For windows without labeled U-factors, describe features:
#Panes _ Frame Type Thermal Break? _ Yes _ No
Comments:
Doors:
❑ Door 1: Solid, U-factor: 0.200
Comments:
❑ Door 2: Glass, U-factor: 0.350
Comments:
Heating and Cooling Equipment:
❑ Furnace 1: Forced Hot Air: 90 AFUE or higher
Make and Model Number:
Air Leakage:
❑ Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed.
❑ Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from
combustible materials. If non -IC rated, the fixture must be installed with a 3" clearance from insulation.
Vapor Retarder:
❑ Required on the warm -in -winter side of all non -vented framed ceilings, walls, and floors.
Materials Identification:
❑ Materials and equipment must be installed in accordance with the manufacturer's installation instructions.
❑ Materials and equipment must be identified so that compliance can be determined.
❑ Manufacturer manuals for all installed heating and cooling equipment and service water healing equipment must be provided,
❑ Insulation R-values, glazing U-factors, and heating equipment efficiency must be clearly marked on the building plans or
specifications.
Oakbrook of 31, "Newport B Spec" Page 2 of 4
E5
Duct Insulation:
❑ Ducts in unconditioned spaces must be insulated to R-5. Ducts outside the building must be insulated to R-8.0.
Duct Construction:
❑ All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives),
mastic -plus -embedded -fabric, or tapes. Tapes and mastics must be rated UL 181A or UL 181 B.
Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500
Pa).
❑ The HVAC system must provide a means for balancing air and water systems.
Temperature Controls:
❑ Thermostats are required for each separate HVAC system. A manual or automatic means to partially restrict or shut off the
heating and/or cooling input to each zone or floor shall be provided.
Service Water Heating:
❑ Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral
heat trap or is part of a circulating system.
❑ Insulate circulating hot water pipes to the levels in Table 1.
Circulating Hot Water Systems:
❑ Insulate circulating hot water pipes to the levels in Table 1.
Swimming Pools:
❑ All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from
non-depletable sources. Pool pumps require a time clock.
Heating and Cooling Piping Insulation:
❑ HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F must be insulated to the levels in Table
2.
Oakbrook Lot 31, "Newport B Spec" Page 3 of 4
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes
Insulation Thickness in Inches by Pipe Sizes
Non -Circulating Runouts
Circulating Mains and Runouts
Heated Water
Temperature ("F)
Up to 1"
Up to 1.25"
1.5" to 2.0" Over 2"
170-180
0.5
1.0
1.5 2.0
140-169
0.5
0.5
1.0 1.5
100-139
0.5
0.5
0.5 1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes
Fluid Temp.
Insulation Thickness In Inches by Pipe Sizes
Piping System Types
Range(°F)
2" Runouts 1" and Less
1.25" to 2.0"
2.5" to 4"
Heating Systems
Low Pressure/Temperature
201-250
1.0
1.5
1.5
2.0
Low Temperature
120-200
0.5
1.0
1.0
1.5
Steam Condensate (for feed water)
Any
1.0
1.0
1.5
2.0
Cooling Systems
Chilled Water, Refrigerant and
40-55
0.5
0.5
0.75
1.0
Brine
Below 40
1.0
1.0
1.5
1.5
NOTES TO FIELD: (Building Department Use Only)