Loading...
HomeMy WebLinkAboutRESCHECK - 07-00073 - The Meadows - Bldg #16�. Permit # Permit Date REScheck Software Version 3.7.3 Compliance Certificate Project Title: The Meadows Townhomes Report Date: 03/28/07 Data filename: C:\Documents and Settings\Chris Jaussi\My Documents\PROJECTS\REXBURG MEADOWS\New Townhome Res Check.rck Energy Code: 2000 IECC Location: Rexburg, Idaho Construction Type: Multifamily Glazing Area Percentage: 13% Heating Degree Days: 8693 Construction Site: Countryside Avenue Rexburg, ID 83440 Owner/Agent: Chris Jaussi Timberhawk Inc. P.O. Box 665 Vernal, UT 84078 (435) 790-8194 chrisj@timberhawk.com Designer/Contractor: Tim Jessop Jessop design group, inc. P.O. Box 65711 Salt Lake City, UT 84078 (801) 598-1050 Compliance: Passes Maximum UA: 737 Your Home UA: 463 --> 37.2% Better Than Code (UA) Ceiling 1: Flat Ceiling or Scissor Truss: 2880 0.0 38.0 72 Wall 1: Wood Frame, 24" o .c.: 3712 22.0 0.0 167 Window 1: Vinyl Fmme:Double Pane: 466 0.320 149 Door 1: Solid: 80 0.160 13 Door 2: Solid: 80 0.250 20 Crawl 1: Solid Concrete or Masonry: 696 0.0 13.0 42 Air Conditioner 1: Electric Central Air: 13 SEER Furnace 1: Forced Hot Air: 80 AFUE Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in REScheck Version 3.7.3 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Builder/Designer Company Name Date The Meadows Townhomes Page 1 of 4 I REScheck Software Version 3.7.3 Inspection Checklist Date: 03/28/07 Ceilings: ❑ Ceiling 1: Flat Ceiling or Scissor Truss, R-38.0 continuous insulation Comments: Above -Grade Walls: ❑ Wall 1: Wood Frame, 24" o .c., R-22.0 cavity insulation Comments: Windows: ❑ Window 1: Vinyl Frame:Double Pane, U-factor: 0.320 For windows without labeled U-factors, describe features: #Panes Frame Type Thermal Break? _ Yes _ No Comments: Doors: ❑ Door 1: Solid, U-factor: 0.160 Comments: ❑ Door 2: Solid, U-factor. 0.250 Comments: Crawl Space Walls: ❑ Crawl 1: Solid Concrete or Masonry, 3.0' htt2.5' bg/3.0' insul, R-13.0 continuous insulation Comments: Exterior insulation must have a rigid, opaque, weather -resistant protective covering that covers the exposed (above -grade) insulation and extends at least 6 in. below grade. Heating and Cooling Equipment: ❑ Air Conditioner 1: Electric Central Air: 13 SEER or higher Make and Model Number. ❑ Furnace 1: Forced Hot Air: 80 AFUE or higher Make and Model Number: Air Leakage: ❑ Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed. ❑ Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from combustible materials, If non -IC rated, the fixture must be installed with a 3" clearance from insulation. Vapor Retarder: ❑ Required on the warm -in -winter side of all non -vented framed ceilings, walls, and Floors. Materials Identification: ❑ Materiels and equipment must be installed In accordance with the manufacturer's Installation instructions. ❑ Materials and equipment must be identified so that compliance can be determined. ❑ Manufacturer manuals for all installed healing and cooling equipment and service water heating equipment must be provided. ❑ Insulation R-values, glazing U-factors, and heating equipment efficiency must be clearly marked on the building plans or specifications. The Meadows Townhomes Page 2 of 4 `� Duct Insulation: ❑ Ducts in unconditioned spaces must be insulated to R-5. Ducts outside the building must be insulated to R-8.0. Duct Construction: ❑ All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives), mastic -plus -embedded -fabric, or tapes. Tapes and mastics must be rated UL 181A or UL 181 B. Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500 Pa). ❑ The HVAC system must provide a means for balancing air and water systems. Temperature Controls: ❑ Thermostats are required for each dwelling unit (non -dwelling areas must have one thermostat for each system or zone). A manual or automatic means to partially restrict or shut off the heating and/or cooling input to each room shall be provided. Electric Systems: ❑ Separate electric meters are required for each dwelling unit. Service Water Heating: ❑ Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral heat trap or is part of a circulating system. ❑ Insulate circulating hot water pipes to the levels in Table 1. Circulating Hot Water Systems: ❑ Insulate circulating hot water pipes to the levels in Table 1. Swimming Pools: ❑ All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from non-depletable sources. Pool pumps require a time clock. Heating and Cooling Piping Insulation: ❑ HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F must be insulated to the levels in Table 2. The Meadows Townhomes Page 3 of 4 Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes Insulation Thickness in Inches by Pipe Sizes Non -Circulating Runouts Circulating Mains and Runouts Heated Water Temperature (°F) Up to 1" Up to 1.25" 1.5" to 2.0" Over 2" 170-180 0.5 1.0 1.5 2.0 140-169 0.5 0.5 1.0 1.5 100-139 0.5 0.5 0.5 1.0 Table 2: Minimum Insulation Thickness for HVAC Pipes Fluid Temp. Insulation Thickness in Inches by Pipe Sizes Piping System Types Rangeff) 2" Runouts 1" and Less 1.25" to 2.0" 2.5" to 4" Heating Systems Low Pressure/Temperature 201-250 1.0 1.5 1.5 2.0 Low Temperature 120-200 0.5 1.0 1.0 1.5 Steam Condensate (for feed water) Any 1.0 1.0 1.5 2.0 Cooling Systems Chilled Water, Refrigerant and 40-55 0.5 0.5 0.75 1.0 Brine Below 40 1.0 1.0 1.5 1.5 NOTES TO FIELD: (Building Department Use Only) The Meadows Townhomes Page 4 of 4