HomeMy WebLinkAboutRESCHECK - 07-00073 - The Meadows - Bldg #16�. Permit #
Permit Date
REScheck Software Version 3.7.3
Compliance Certificate
Project Title: The Meadows Townhomes
Report Date: 03/28/07
Data filename: C:\Documents and Settings\Chris Jaussi\My Documents\PROJECTS\REXBURG MEADOWS\New Townhome Res
Check.rck
Energy Code:
2000 IECC
Location:
Rexburg, Idaho
Construction Type:
Multifamily
Glazing Area Percentage:
13%
Heating Degree Days:
8693
Construction Site:
Countryside Avenue
Rexburg, ID 83440
Owner/Agent:
Chris Jaussi
Timberhawk Inc.
P.O. Box 665
Vernal, UT 84078
(435) 790-8194
chrisj@timberhawk.com
Designer/Contractor:
Tim Jessop
Jessop design group, inc.
P.O. Box 65711
Salt Lake City, UT 84078
(801) 598-1050
Compliance: Passes Maximum UA: 737 Your Home UA: 463 --> 37.2% Better Than Code (UA)
Ceiling 1: Flat Ceiling or Scissor Truss:
2880 0.0 38.0
72
Wall 1: Wood Frame, 24" o .c.:
3712 22.0 0.0
167
Window 1: Vinyl Fmme:Double Pane:
466 0.320
149
Door 1: Solid:
80 0.160
13
Door 2: Solid:
80 0.250
20
Crawl 1: Solid Concrete or Masonry:
696 0.0 13.0
42
Air Conditioner 1: Electric Central Air: 13 SEER
Furnace 1: Forced Hot Air: 80 AFUE
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2000 IECC requirements in
REScheck Version 3.7.3 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
Builder/Designer Company Name Date
The Meadows Townhomes
Page 1 of 4
I
REScheck Software Version 3.7.3
Inspection Checklist
Date: 03/28/07
Ceilings:
❑ Ceiling 1: Flat Ceiling or Scissor Truss, R-38.0 continuous insulation
Comments:
Above -Grade Walls:
❑ Wall 1: Wood Frame, 24" o .c., R-22.0 cavity insulation
Comments:
Windows:
❑ Window 1: Vinyl Frame:Double Pane, U-factor: 0.320
For windows without labeled U-factors, describe features:
#Panes Frame Type Thermal Break? _ Yes _ No
Comments:
Doors:
❑ Door 1: Solid, U-factor: 0.160
Comments:
❑ Door 2: Solid, U-factor. 0.250
Comments:
Crawl Space Walls:
❑ Crawl 1: Solid Concrete or Masonry, 3.0' htt2.5' bg/3.0' insul, R-13.0 continuous insulation
Comments:
Exterior insulation must have a rigid, opaque, weather -resistant protective covering that covers the exposed (above -grade)
insulation and extends at least 6 in. below grade.
Heating and Cooling Equipment:
❑ Air Conditioner 1: Electric Central Air: 13 SEER or higher
Make and Model Number.
❑ Furnace 1: Forced Hot Air: 80 AFUE or higher
Make and Model Number:
Air Leakage:
❑ Joints, penetrations, and all other such openings in the building envelope that are sources of air leakage must be sealed.
❑ Recessed lights must be 1) Type IC rated, or 2) installed inside an appropriate air -tight assembly with a 0.5" clearance from
combustible materials, If non -IC rated, the fixture must be installed with a 3" clearance from insulation.
Vapor Retarder:
❑ Required on the warm -in -winter side of all non -vented framed ceilings, walls, and Floors.
Materials Identification:
❑ Materiels and equipment must be installed In accordance with the manufacturer's Installation instructions.
❑ Materials and equipment must be identified so that compliance can be determined.
❑ Manufacturer manuals for all installed healing and cooling equipment and service water heating equipment must be provided.
❑ Insulation R-values, glazing U-factors, and heating equipment efficiency must be clearly marked on the building plans or
specifications.
The Meadows Townhomes Page 2 of 4
`�
Duct Insulation:
❑ Ducts in unconditioned spaces must be insulated to R-5. Ducts outside the building must be insulated to R-8.0.
Duct Construction:
❑ All joints, seams, and connections must be securely fastened with welds, gaskets, mastics (adhesives),
mastic -plus -embedded -fabric, or tapes. Tapes and mastics must be rated UL 181A or UL 181 B.
Exception: Continuously welded and locking -type longitudinal joints and seams on ducts operating at less than 2 in. w.g. (500
Pa).
❑ The HVAC system must provide a means for balancing air and water systems.
Temperature Controls:
❑ Thermostats are required for each dwelling unit (non -dwelling areas must have one thermostat for each system or zone). A
manual or automatic means to partially restrict or shut off the heating and/or cooling input to each room shall be provided.
Electric Systems:
❑ Separate electric meters are required for each dwelling unit.
Service Water Heating:
❑ Water heaters with vertical pipe risers must have a heat trap on both the inlet and outlet unless the water heater has an integral
heat trap or is part of a circulating system.
❑ Insulate circulating hot water pipes to the levels in Table 1.
Circulating Hot Water Systems:
❑ Insulate circulating hot water pipes to the levels in Table 1.
Swimming Pools:
❑ All heated swimming pools must have an on/off heater switch and require a cover unless over 20% of the heating energy is from
non-depletable sources. Pool pumps require a time clock.
Heating and Cooling Piping Insulation:
❑ HVAC piping conveying fluids above 105 degrees F or chilled fluids below 55 degrees F must be insulated to the levels in Table
2.
The Meadows Townhomes Page 3 of 4
Table 1: Minimum Insulation Thickness for Circulating Hot Water Pipes
Insulation Thickness in Inches by Pipe Sizes
Non -Circulating Runouts
Circulating Mains and Runouts
Heated Water
Temperature (°F)
Up to 1"
Up to 1.25"
1.5" to 2.0" Over 2"
170-180
0.5
1.0
1.5 2.0
140-169
0.5
0.5
1.0 1.5
100-139
0.5
0.5
0.5 1.0
Table 2: Minimum Insulation Thickness for HVAC Pipes
Fluid Temp.
Insulation Thickness in Inches by Pipe Sizes
Piping System Types
Rangeff)
2" Runouts 1" and Less
1.25" to 2.0"
2.5" to 4"
Heating Systems
Low Pressure/Temperature
201-250
1.0
1.5
1.5
2.0
Low Temperature
120-200
0.5
1.0
1.0
1.5
Steam Condensate (for feed water)
Any
1.0
1.0
1.5
2.0
Cooling Systems
Chilled Water, Refrigerant and
40-55
0.5
0.5
0.75
1.0
Brine
Below 40
1.0
1.0
1.5
1.5
NOTES TO FIELD: (Building Department Use Only)
The Meadows Townhomes Page 4 of 4