Loading...
HomeMy WebLinkAboutPROJECT SUMMARY - 07-00072 - 1892 W 2870 S - New SFR MechanicalProjectMummary Entire House JRW Rexburg, ID 83440 • 1 For: Dave anderson Notes: Job: Dave Anderson Date: Feb 27, 2007 By: 0700072 1892 W 2870 S-Cnty Mech Weather: Idaho Falls, ID, US Winter Design Conditions Outside db Inside db Design TD -6 OF 70 OF 76 OF Heating Summary Structure 23348 Btuh Ducts 3617 cfm Central vent (36 cfm) 2528 Btuh Humidification 0 Btuh Piping 0 Btuh Equipment load 29493 Btuh Infiltration Method Simplified Construction quality Average Fireplaces 0 Heatingg Coolingg Area (ftz) 1800 1800 Volume (ft3) 14400 14400 Air changes/hour 0.38 0.20 Equiv. AVF (cfm) 91 48 Heating Equipment Summary Make Trade Model Efficiency Heating Input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 80 AFUE 0 Btuh 0 Btuh 0 OF 381 cfm 0.014 cfm/Btuh 0.00 in H2O Summer Design Conditions Outside db 89 OF Inside db 75 OF Design TO 14 OF Daily range H Relative humidity 50 % Moisture difference -31 gr/lb Sensible Cooling Equipment Load Sizing Structure 5287 Btuh Ducts 2489 Btuh Central vent (36 cfm) 466 Btuh Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.94 Equipment sensible load 7747 Btuh Latent Cooling Equipment Load Sizing Structure -863 Btuh Ducts -56 Btuh Central vent (36 cfm) -647 Btuh Equipment latent load 0 Btuh Equipment total load 7747 Btuh Req. total capacity at 0.70 SHR 0.9 ton Cooling Equipment Summary Make Trade Cond Coil Efficiency Sensible cooling Latent cooling Total cooling Actual air flow Air flow factor Static pressure Load sensible heat ratio Printout certified by ACCA to meet all requirements of Manual J 8th Ed. 0 EER 0 Btuh 0 Btuh 0 Btuh 381 cfm 0.049 cfm/Btuh 0.00 in H2O 1.00 wnghtsofC Right -Suite Residential60.22 RSR40897 2007-Feb-2710:11:08 AM Projectl.up Calc = MJ8 Orientation = N Page 1 Short Form Entire House JRW Rexburg, ID 03"0 Project• • For: Dave anderson Job: Dave Anderson Date: Feb 27, 2007 By: Htg Clg Infiltration Outside db (OF) -6 89 Method Simplified Inside db (OF) 70 75 Construction quality Average Design TD (OF) 76 14 Fireplaces 0 Daily range - H Inside humidity (%) 50 Moisture difference (gr/lb) -31 HEATING EQUIPMENT Make Trade Model Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 80 AFUE 0 Btuh 0 Btuh 0 OF 381 cfm 0.014 cfm/Btuh 0.00 in H2O COOLING EQUIPMENT Make Trade Cond Coil Efficiency 0 EER Sensible cooling 0 Btuh Latent cooling 0 Btuh Total cooling 0 Btuh Actual air flow 381 cfm Air flow factor 0.049 cfm/Btuh Static pressure 0.00 in H2O Load sensible heat ratio 1.00 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft') (Btuh) (Btuh) (cfm) (cfm) Room1 376 7330 1941 104 95 Room2 1424 19635 5835 277 286 Entire House 1800 26965 7776 381 381 Other equip loads 2528 466 Equip. @ 0.94 RSM 7747 Latent cooling 0 11n7 004 104 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. Wnghtsoft Right-Sutte Residential 6.0.22 RSR40897 2D07-Fab-2710,11:08 P.1ectl." Cale = MJ8 Orientation = N Page 1 Sheet 1 Job #: Dave Anderson I JRW Performed for: Dave anderson Rexburg, ID 83440 Scale: 1 : 86 Page i Right -Suite Residential 6.0.22 RSR40897 2007-Feb-27 10:12:00 Projecti.rrp