HVAC CALCS - 07-00053 - 3865 W 2000 N - New SFR Mechanical
Page 1 Report Prepared By: � &/ 00053 Residential Heat Loss ar 3865 `]V 2000 N-Cnty Mech In accordance wits r lIVVl1 Ivia, lull J Mountain West Mechanical Inc. For: Robert Gulley Rexburg, ID Design Conditions: Rexburg Indoor: Outdoor: Summer temperature: 75 Summer temperature: 87 Winter temperature: 70 Winter temperature: -25 Relative humidity: 55 Summer grains of moisture: 40 Daily temperature range: Low Building Component Sensible Latent Total Total Gain Gain Heat Gain Heat Loss (BTUH) (BTUH) (BTUH) (BTUH) Windows 5,041 0 5,041 9,847 People 2,100 1,610 3,710 0 Ceilings 2,084 0 2,084 4,949 Duct 1,897 0 1, 897 10,027 Infiltration _ 1,320 _ 0 1,320 10,450 Walls 1,232 0 1_,232 1_1,668 Glassdoors 643 0 643 2,083 Doors Skylights --- -- - ---- - -- Misc Fireplaces ^ Floors Whole House - 229 - - - 0 229 1,112 0 0 0 0 0 0 0 0 14,546 1,610 16,156 509136 HVAC-Calc Residential 4.0 by HVAC Computer Systems Ltd. 888 736-1101 Load calculations are estimates only, actual loads may vary due to weather and construction differences. '"Ov Page 1 Residential Heat Loss and Heat Gain Calculation In accordance with ACCA Manual J Report Prepared By: Mountain West Mechanical Inc. For: Robert Gulley Rexburg, ID Design Conditions: Rexburg Indoor: Summer temperature: 75 Winter temperature: 70 Relative humidity: 55 Building Component Sensible Gain (BTUH) Whole House — 21949 sq.ft. — 149546 Basement 4,005 All Rooms 1,404 sq.ft. 4,005 Main Floor 10,541 All Rooms 1,545 sq.ft. 10,541 Whole House 2,949 sq.ft. 149546 1 /16/2007 Outdoor: Summer temperature: 87 Winter temperature: -25 Summer grains of moisture: 40 Daily temperature range: Low Latent Total Total Gain Heat Gain Heat Loss (BTUH) (BTUH) (BTUH) 19610 161156 509136 460 4,465 17,392 460 4,465 17,392 1,150 11,691 32,744 1,150 11,691 32,744 19610 161156 50,136 HVAC-Calc Residential 4.0 by HVAC Computer Systems Ltd. 888 736-1101 Load calculations are estimates only, actual loads may vary due to weather and construction differences. en Page 1 Residential Heat Loss and Heat Gain Calculation 1 /16/2007 In accordance with ACCA Manual J Report Prepared By: Mountain West Mechanical Inc. For: Robert Gulley Rexburg, ID Design Conditions: - Rexburg Indoor: Outdoor: Summer temperature: 75 Summer temperature: 87 Winter temperature: 70 Winter temperature: -25 Relative humidity: 55 Summer grains of moisture: 40 Daily temperature range: Low Building Component Sensible Latent Total Total Gain Gain Heat Gain Heat Loss (BTUH) (BTUH) (BTUH) (BTUH) Whole House 14,546 1,610 169156 509136 Basement 4,005 460 4,465 17,392 All Rooms 4,005 460 41465 17,392 Infiltration 331 0 331 2,622 Duct 522 0 522 3,478 People 600 460 1,060 0 Floor 0 0 0 0 W Wall BelowGr 0 0 0 1,531 Window 1,368 0 1,368 2,450 N Wall BelowGr 0 0 0 1,143 Window 256 0 256 942 S Wall BelowGr 0 0 0 1,783 E Wall BelowGr 0 0 0 1,240 Ceiling 928 0 928 2,203 Main Floor 10,541 1,150 11,691 32,744 All Rooms 10,541 1,150 11,691 32,744 Infiltration 989 0 989 7,828 Duct 1,375 0 1,375 6,549 People 1,500 1,150 2,650 0 `r1 llft� Page 2 Building Component Floor E Wall Window Door S Wall Door W Wall Window Glassdoor N Wall Ceiling Whole House Robert Gulley 1 /16/2007 Sensible Latent Total Total Gain Gain Heat Gain Heat Loss (BTUH) (BTUH) (BTUH) (BTUH) 0 0 0 0 285 0 285 1,382 1,972 0 1,972 3,534 162 0 162 787 233 0 233 1,131 67 0 67 325 463 0 463 2,242 1,445 0 1,445 2,921 643 0 643 2,083 251 0 251 1,216 1,156 0 1,156 2,746 14,546 1,610 16,166 50,136 HVAC-Calc Residential 4.0 by HVAC Computer Systems Ltd. _ 888 736-1101 Load calculations are estimates only, actual loads may vary due to weather and construction differences. �Ur Residential Heat Loss and Heat Gain Calculation In accordance with ACCA Manual J Report Prepared By: Mountain West Mechanical Inc. For: Robert Gulley Rexburg, ID Design Conditions: Rexburg Indoor: Summer temperature: 75 Winter temperature: 70 Relative humidity: 55 Building Component Whole House Basement All Rooms Infiltration Duct People Floor W Wall BelowGr Window N Wall BelowGr Window S Wall BelowGr E Wall BelowGr Ceiling Main Floor All Rooms Infiltration Duct People 29949 sq.ft. 1,404 sq.ft. 2 1,404 sq.ft. 316 sq.ft. 52 sq.ft. 236 sq.ft. 20 sq.ft. 368 sq.ft. 256 sq.ft. 1,364 sq.ft. 1,545 sq.ft. 5 Sensible Gain (BTUH) 14,646 4,005 4,005 331 - - 522 600 0 0 1,368 0 256 0 0 928 10,541 10,541 989 1,375 1,500 1/16/2007 Outdoor: Summer temperature: 87 Winter temperature: -25 Summer grains of moisture: 40 Daily temperature range: Low Latent Total Total Gain Heat Gain Heat Loss (BTUH) (BTUH) (BTUH) 10610 160156 50,136 460 4,465 17,392 460 41465 17,392 0 331 2,622 0 522 3,478 460 1,060 0 0 0 0 0 0 1,531 0- - - 1,368 20450 0 0 1,143 0 256 942 0 0 1,783 0 0 1,240 0 928 2,203 1,150 11,691 32,744 1,150 11,691 32,744 0 989 7,828 0 1,375 6,549 1,150 2,650 0 �% / ti111✓ Page 2 Building Component Floor E Wall Window Door S Wall Door W Wall Window Glassdoor N Wall Ceiling Whole House Robert Gulley 1 /16/2007 Sensible Latent Total Total Gain Gain Heat Gain Heat Loss (BTUH) (BTUH) (BTUH) (BTUH) 1,545 sq.ft. 0 0 0 0 291 sq.ft. 285 0 285 1,382 75 sq.ft. 1,972 0 1,972 3,534 18 sq.ft. 162 0 162 787 238 sq.ft. 233 0 233 11131 18 sq.ft. 67 0 67 325 472 sq.ft. 463 0 463 2,242 62 sq.ft. 1,445 0 1,445 2,921 42 sq.ft. 643 0 643 2,083 256 sq.ft. 251 0 251 1,216 1,700 sq.ft. 10156 0 11156 _ 21746 2,949 sq.ft. 14,546 — 1,610 16,156^ 501136 HVAC-Calc Residential 4.0 by HVAC Computer Systems Ltd. 888 736-1101 Load calculations are estimates only, actual loads may vary due to weather and construction differences. on Pagel Residential Heat Loss and Heat Gain Calculation 1/16/2007 In accordance with ACCA Manual J Report Prepared By: Mountain West Mechanical Inc. For: Robert Gulley Rexburg, ID Design Conditions: Rexburg Indoor: Outdoor: Summer temperature: 75 Summer temperature: 87 Winter temperature: 70 Winter temperature: -25 Relative humidity: 55 Summer grains of moisture: 40 Daily temperature range: Low Building Component Sensible Total Latent Total Gain Gain Heat Gain Heat Loss (BTUH) (BTUH) (BTUH) (BTUH) Whole House 14,546 — 19610 16,156 509136 Basement 4,005 460 4,465 17,392 All Rooms _ 4,005 460 4,465 171392 Infiltration 331 0 331 2,622 -Tightness: Best; Winter ACH: 0 ; Summer ACH: 0 - - Duct -522 0 522 3,478 - Supply above 120; Enclosed in unheated space_; None People 600 460 1,060 0 Floor 0 0 0 0 - Over conditioned space W Wall BelowGr 0 0 0 1,531 - Block or brick, extends to 5' below grade; R-11 3 1/2 in.; 8 or 12 in. Block Window 1,368 0 1,368 2,450 - Double pane; Vinyl frame; Clear glass - Draperies or blinds; Coating: None (clear glass); 55% shaded. N Wall BelowGr 0 0 0 1,143 - Block or brick, extend_ s to 5' below grade; R-11 3 1/2 in.; 8 or 12 in. Block Window 256 0 256 942 - Double pane; Vinyl frame; Clear glass - Draperies or blinds; Coating: None (clear glass); 55% shaded. S Wall BelowGr 0 0 0 1,783 - Block or brick, extends to 5' below grade; R-11 3 1/2 in.; 8 or 12 in. Block E Wall BelowGr 0 0 0 1,240 - Block or brick, extends to 5' below_ _grade; R-11 3 1/2 in.; 8 or 12 in. Block Ceiling 928 0 928 2,203 - Under ventilated attic; R-57 (16 inch); Dark Main Floor 10,541 1,150 11,691 32,744 1400 Page 2 Robert Gulley 1/16/2007 Building Component Sensible Latent Total Total Gain Gain Heat Gain Heat Loss (BTUH) (BTUH) (BTUH) (BTUH) All Rooms _ 10,541 1,15.0 11,691 32,744 Infiltration 989 0 989 7,828 - Tightness: Best; Winter ACH: 0 ; Summer ACH: 0 Duct 1,375 0 1,375 6,549 - Supply above 120; Enclosed in unheated space; None People 1,500 1,150 2,650 0 Floor 0 0 0 0 - Over conditioned_ space E Wall 285 0 285 1,382 - Wood frame, with sheathing, siding or brick; R-19 5 1/2 in.; R-2.5 1/2 in. Extruded poly board Window 1,972 0 1,972 3,534 - Double pane; Vinyl frame; Clear glass - Draperies or blinds; Coating: None (clear glass); 55% shaded. Door 162 0 162 787 - Wood; Solid;_ No storm S Wall 233 0 233 1,131 - Wood frame, with sheathing, siding_ or brick; R-19 5 1/2 in.; R-2.5 1/2 in. Extruded poly board Door 67 0 67 325 - Metal; Urethane; No storm W Wall 463 0 463 2,242 - Wood frame, with sheathing, siding or brick; R-19 5 1/2 in.; R-2.5 1/2 in. Extruded poly board Window 1,445 0 1,445 2,921 - Double pane; Vinyl frame; Clear glass - Draperies or blinds; Coating: None (clear glass); 65% shaded. Glassdoor 643 0 643 2,083 - French doors; Double pane; Wood or vinyl frame; Clear glass - Draperies or blinds; Coating: Tinted (heat absorbing); 75% shaded. N Wall 251 0 251 1,216 - Wood frame, with sheathing, siding or brick; R-19 51/2 in.; R-2.5 1/2 in. Extruded poly board Ceiling 1,156 0 1,156 2,746 - Under ventilated attic; R-57 (16 inch); Dark Whole House 14,646 1,610 16,156 50,136 HVAC-Calc Residential 4.0 by HVAC Computer Systems Ltd. 888 736-1101 Load calculations are estimates only, actual loads may vary due to weather and construction differences. Page 1 Report Prepared By: For: Residential Heat Loss and Heat Gain Calculation In accordance with ACCA Manual J Mountain West Mechanical Inc. Robert Gulley Rexburg, ID Design Conditions: Rexburg Indoor: Summer temperature: Winter temperature: Relative humidity: 1'q&%jnnn-7 Outdoor: 75 Summer temperature: 87 70 Winter temperature: -25 55 Summer grains of moisture: 40 Daily temperature range: Low Building Component Sensible Latent Total Total Gain Gain Heat Gain Heat Loss (BTUH) (BTUH) (BTUH) (BTUH) Whole House 2,949 sq.ft. 14,546 1,610 16,156� 50,136 Basement 4,005 460 a 4,465 17,392 All Rooms 1,404 sq.ft. 4,005 460 4,465 17,392 Infiltration 331 0 331 2 622 - Tightness: Best; Winter ACH: 0 ; Summer A_CH: 0 Duct 522 0 522 - Supply above 120; Enclosed in unheated space; None People 2 600 460 1,060 Floor 1,404 sq.ft. 0 0 0 - Over conditioned space W Wall BelowGr 316 sq.ft. 0 0 0 - Block or brick, extends to 5' below grade; R-11 31/2 in.; 8 or 12 in. Block Window 52 sq.ft. 1,368 0 1,368 - Double pane; Vinyl frame; Clear glass - Draperies or blinds; Coating: None (clear glass); 55% shaded. N Wall BelowGr 236 sq.ft. 0 0 0 - Block or brick, extends to 5' below grade; R-11 3 1/2 in.; 8 or 12 in. Block Window 20 sq.ft. 256 0 256 - Double pane; Vinyl frame; Clear glass - Draperies or blinds; Coating: None (clear glass); 55% shaded. S Wall BelowGr 368 sq.ft. 0 0 0 - Block or brick, extends to 5' below grade; R-11 31/2 in.; 8 or 12 in. Block E Wall BelowGr 256 sq.ft. 0 0 0 - Block or brick, extends to 5' below grade; R-11 31/2 in.; 8 or 12 in. Block Ceiling 1,364 sq.ft. 928 0 928 - Under ventilated attic; R-57 (16 inch); Dark Main Floor 10,541 1,150 11,691 3,478 0 0 1,531 2,450 1,143 942 1,783 1,240 2,203 32,744 lft ✓ Page 2 Robert Gulley 1/16/2007 Building Component Sensible Latent Total Total Gain Gain Heat Gain Heat Loss (BTUH) (BTUH) (BTUH) (BTUH) All Rooms 1,545 sq.ft. 10,541 1,150 11,691 32,744 Infiltration 989 0 989 7,828 - Tightness: Best; Winter ACH: 0 ; Summer ACH: 0 Duct 1,375 0 1,375 6,549 - Supply above 120; Enclosed in unheated space; None People 5 1,500 1,150 2,650 0 Floor 1,545 sq.ft. 0 0 0 0 - Over conditioned space E Wall 291 sq.ft. 285 0 285 1,382 - Wood frame, with sheathing, siding or brick; R-19 51/2 in.; R-2.5 1/2 in. Extruded poly board Window 75 sq.ft. 1,972 0 1,972 3,534 - Double pane; Vinyl frame; Clear glass - Draperies or blinds; Coating: None (clear glass); 55% shaded. Door 18 sq.ft. 162 0 162 787 - Wood; Solid; No storm S Wall 238 sq.ft. 233 0 233 1,131 - Wood frame, with sheathing, siding or brick; R-19 51/2 in.; R-2.5 1/2 in. Extruded poly board Door 18 sq.ft. 67 0 67 325 - Metal; Urethane; No storm W Wall 472 sq.ft. 463 0 463 2,242 - Wood frame, with sheathing, siding or brick; R-19 51/2 in.; R-2.5 1/2 in. Extruded poly board Window 62 sq.ft. 1,445 0 1,445 21921 - Double pane; Vinyl frame; Clear glass --Draperies or blinds; Coating: None (clear glass); 65% shaded. Glassdoor 42 sq.ft. 643 0 643 2,083 - French doors; Double pane; Wood or vinyl frame; Clear glass - Draperies or blinds; Coating: Tinted (heat absorbing); 75% shaded. N Wall 256 sq.ft. 251 0 251 1,216 - Wood frame, with sheathing, siding or brick; R-19 51/2 in.; R-2.5 1/2 in. Extruded poly board Ceiling 1,700 sq.ft. 1,156 0 1,156 2,746 - Under ventilated attic; R-57 (16 inch); Dark Whole House 2,949 sq.ft. 14,546 1,610 16,166 50,136 HVAC-Calc Residential 4.0 by HVAC Computer Systems Ltd. 888 736-1101 Load calculations are estimates only, actual loads may vary due to weather and construction differences. Page 1 Residential Heat Loss and Heat Gain Calculation In accordance with ACCA Manual J Report Prepared By: Mountain West Mechanical Inc. For: Robert Gulley Rexburg, ID Total CFM: 600 1 /16/2007 Room Cooling CFM Heating CFM Both Basement 165 _ 208 J _ 208 All Rooms 165 208 208 Main Floor 435 392 435 All Rooms 435 392 435 HVAC-Calc Residential 4.0 by HVAC Computer Systems Ltd. v 888 736-1101 Load calculations are estimates only, actual loads may vary due to weather and construction differences. \"011 Page 1 Duct Sizing Report Report Prepared By: Mountain West Mechanical Inc. For: Robert Gulley Rexburg, ID 1 /16/2007 Rooms Serviced All Rooms All Rooms Supply or Return Material CFM FPM Duct Size Supply Rigid 643 900 18 X 6 HVAC-Calc Residential 4.0 by HVAC Computer Systems Ltd. 888 736-1101 Load calculations are estimates only. actual loads may very due to weather and construction di8ersnces.