Loading...
HomeMy WebLinkAboutPROJECT INFO - 07-00028 - 265 Polo Dr - New SFRQ aFace vAc CITY 4F REXBURG -- N,- Americas rwmity Community SINGLE FAMILY RESIDENTIAL Project Information Permit Type Single Family Residential Site Address 265 POLO DR Project Description Fee Information City of Rexburg Department of Community Development 19 E. Main St. / Rexburg, ID. 83440 Phone (208) 359-3020 / Fax (208) 359-3022 Project Valuation $322,666.9E Permit - Electrical 160.00 Mechanical Residential Fixtures 155.00 Building Permit Fee 25242.55 Plan Check Fee 224.26 Residential Plumbing Permit Fee 216.00 Fire Impact 184.61 Hookup Fee/Sewer 1,000.00 Hookup Fee/Water 1,550.00 Park Impact Fee 604.97 Police Impact Fee 158.11 Street Impact Fee 804.25 Water Meter & Parts 317.00 Total Fees Paid $7,616.75 i Print Name Signature Permit # 0700028 Project Name 265 Polo Drive -Haycock Parcel # RPRHNDS3070130 Project Details Residential, one and two family (Any Code mat, Utility, miscellaneous, private garages (Any Co( Date Date Issued: Issued By: 3,400 SQFT 858 SQFT SINGLEFAMILY RESIDENTIAL CITY OF REXBZJRG City of Rexburg Amaicz*A►nilyCommunity Department of Community Development 19 E. Main St. / Rexburg, ID. 83440 Phone (208) 359-3020 / Fax (208) 359-3022 Project Information Permit # 0700028 Permit Type Single Family Residential Project Name 265 Polo Drive -Haycock Site Address 265 POLO DR Parcel # RPRHNDS3070130 Project Description Names Associated with this Project - Type Name Contact Phone # License # Exp Date Contractor Nomarco Inc Mason Haycock 208-356-3550 RCE-18628 09/26/2007 Contractor Owner EXEMPT 12/31/2010 Fixtures 2 - R-Fuel piping fixture or appliance outlet(s) additional 1- R-Fuel (gas) piping fixture or appliance outlet 1- R-Range hood vents additional 4 - R-Bath fan vents additional 1- R-Exhaust or vent ducts 1- R-Furnace / Air Conditioner Combo - R-Decorative gas -fired appliance(s) additional 1- R-Dryer vents additional 1 - R-Garbage Disposal 1 - R-Water Softener 4 - R-Water Closet and/or Urinal 1- R-Clothes Washing Machine 1 - R-Dish Washer 1- R-Floor Drain 1- R-Water Heater 6 - R-Sink (Lavatory, Kitchen, Mop or Bar Sink) 5 - R-Tub and/or Shower Unit 1- R-Sprinkler Print Name Date Issued: Signature Date Issued By: RESIDENTIAL PLAN CHECKLIST (2003 International Residential Code) Date: _Z- 7 -0 7 Building Permit Number: 07 000 es Project: Job Address: ZAPS 46W Fo(e Dr, Zoning:,l�eZ Number ofStories:� Basement: Yes No in fin. Fixtures: 'ZZ 178Z 2 M��ro b uQQa ammo Floor Area (sf): _finished, unfinished, J[6gamge Mechanical Fee: 1-15 The following comments based on the 2003 edition of the International Residential Code should be resolved before a building permit is issued. This correction list is not a building permit. The approval of plans and specifications does not permit the violation of any section ofthe Intemational Residential Code or any federal, state or local regulations. PLAN CHECK A. Ythfins To Scale _Legible /Piot Plan Y &ood Plain .f--floor / Foundation Plan C �tion showing cortstoction details S5 y. w f vI II Building Elevations Y'--D,sign Criteria (shall be identified on plans as Wind Cross Calculation Sheets & (2�1oor Joist Details /Mechanical Design ZEnergy Calculations (R320 & Ch 11) 85 m.p.h., Snow - 35 lb. Per sq ft.) B. 'Zoning (circle one -new zoning designations adopted in 2005) LDRI 12,000 sf min. (width 80 ft. min) LD 8,000 sf min. (width 60 ft. min); Duplex 10,000 sq. ft. min. with C.U.P. 21,780 sf min. (width 150 ft min) Duplex allowed with C.U.P. Other (Verify zoning requirements) C. we Single Family _Duplex (LDRI only - Conditional use en rmit?l 1-D. S Backs (taken from caves) nt set back (32 ft. from curb) Ante: 60% min of front yard green i'*ar set back (LDRI 25 ft. & LDR2 20 ft.) Sides set backs (6" for every ft. of building height with LDR - 7.5' min., & LDRI - 6' min.) ./Iding-Height (maximum 30 ft.) E. Footings doper Size (as per Table 403.1, use 1500 psf unless soil type is known, Table 401.4.1 for soil bearing) ,elf -bar (244 continuous) ZFooting Depth (36" below finished grade and 12" below undisturbed soil; 18" to top of slab- interior) F. Fp�ndatiom /Foundation walls w/ rebar (city ordinance) .`</2" Anchor Bolts with 2"x 2"x 3/I6" square washers (me], interior bearing walls) R403.1,6.1 Xoundation Drainage (foundations on sift soil shall be designed per R405) /amp proofing(Waterproofing to finish grade. R406.1 (find, extends 6" min above grade R404.1.6) —Crawl space access of 18" x 24" min. R408.3 (may differ if mech appliance is in crawl space M1305.1.4) �Cmwl Space Ventilation/insulation=l sf vent per 150 sf. (with moisture barrier 1 sf. Per 1500 so. ft.) and within Y ofeach comer (insulate walls vent to inside of home) R408.2 �ading slope away from house. R401.3 G. F,Fnfive Seismic Hold Downs and Braced Wall Panels (13602.10) Oloorsjoists sized as per R502.3, Wood I joists sized per manufir. 0oists Under Load Bearing Partitions shall be doubled. R502.4 QGirders sized per R502.5 or per manufr. Tables for engineered products QCantilevers (comply with R502.3.3 or manuG instruction) Floor Sheathing (3/4" min for joists 24" oc & 518" forjoists 16" oc) R503.2.2 /<. 1(bearing and nonbearing) stud sizes, height & spacing per Table 602.3(5) R602.3 Headers in Bearing Wall shall be designed as per Tables 502.5(1&2) R602.7 VRoofTrusses(designed according to R802.10.1) 35 g Snow and 90 mph winds (Local Conditions) After and Truss tie -downs. (R802.10.5) /c Access 22" x 30" min. opening (R807) H.,Exterior Covering t _Masonry and stucco shall have weather resistive barrier over exterior sheathing R703.2 & 703.9.1 f.R f Covering and Ventilation Roof Ventilation as per R806 /Asphalt Shingles (slope>2:12) w/ ice protection. (Other type: to comply w/ R905._) I. FJ'�walls /Garage/House drywall separation (protect ext. walls & beams supporting habitable space) R309.2 Loor from Garage to House (l 318" solid wood or steel door, or 20 min. fire -rated door) 11309.1 —T s, Family Dwelling Separation (1 hr fire separation) Supporting structure also rated. R317.1 ---Twin homes & Tmvnhouses (2 hr sepamtion & 4' overbum protection or parapet) R317.2 -One hr walls parallel to and within 3 fl of property line w/ NO openings. R302 Penetrations in previous 3 items to comply with R317.3 K G eral Requirements use Numbers R321 ' < Half Openable 3sfwindow or Mech. Ventilation in bathrooms, water closets, and similar rooms. R303.3 �terior and exterior stair illumination shall comply with R303.6. /throe m Fixture clearances comply with Figure R307.2 Zone room at least 120 sf; _Other habitable rooms 70 at. min w/ a min. dimension of 7 ft. R304 •areas w/ sloped ceilings less than 5 f} in height & furred ceilings less than 7ft DO NOT comply *50%or more of the required area must be at least 7ft high in rooms w/sloped ceiling I less clearance from window wells under cantilevered Floors. R310.2 Glazing at Hazardous Locations R308 /'Emergency Egress in all sleeping rooms and basements with habitable space R310 /e required Exit Door shall comply with R311.4 '--�Landings at top and bottom of stairways R311.5.4, and each side of each exterior door. R311.4.3 <ir Ri /Run (7 3/4" max. rise & 10" min. read, nosing req'd if <11")_-Star Width (36" min), 7mirway Headroom (68" min.) Handrails (34"to 38" above stair nosing)(R311.5) Special conditions for circular, spiral and winder stairways and bulkhead enclosures R311.&S Stairway Protection (enclosed accessible space under stairs shall be covered with 1/2" drywall) R311.2.2 ,elluardrails complying with R312 F Smoke Alarms (each bedroom and common area and one on each eve) (R 313) L. Energy _Homes with glazing < 15% of gross area of ext. walls (Townhouses <25%) to comply w/ Chapter 11. 'Otherwise shall meet requirements of/ECC for respective building type. N1101.2 jV apor retarder on warts in winter side of walls, ceiling and floors R31S /ter Heater heat traps IECC 504.7 /ucl sealing and insulation N1103.3&4 or IECC 503.3.3.3, 503.3.3.4.3 _Plans match quantities & values on a "passing" REScheck compliance report M. Mechanical Lu. appliances not in bedrooms, bathrooms, toilet rooms, or storage closets G2406.2 loom access 24" min width/Attic access clear opening 2000/Under floor no. 2200. M1305 Drryer Vent length 25' max w/ 8' transition (-5' per 90 deg turns) M1501.3 Flue chase shown on plans (B-vents not to be inside insulated walls without insulation shield)