HomeMy WebLinkAboutPROJECT INFO - 07-00028 - 265 Polo Dr - New SFRQ aFace vAc
CITY 4F
REXBURG
-- N,-
Americas rwmity Community
SINGLE FAMILY RESIDENTIAL
Project Information
Permit Type Single Family Residential
Site Address 265 POLO DR
Project Description
Fee Information
City of Rexburg
Department of Community Development
19 E. Main St. / Rexburg, ID. 83440
Phone (208) 359-3020 / Fax (208) 359-3022
Project Valuation
$322,666.9E
Permit - Electrical
160.00
Mechanical Residential Fixtures
155.00
Building Permit Fee
25242.55
Plan Check Fee
224.26
Residential Plumbing Permit Fee
216.00
Fire Impact
184.61
Hookup Fee/Sewer
1,000.00
Hookup Fee/Water
1,550.00
Park Impact Fee
604.97
Police Impact Fee
158.11
Street Impact Fee
804.25
Water Meter & Parts
317.00
Total Fees Paid $7,616.75
i
Print Name
Signature
Permit # 0700028
Project Name 265 Polo Drive -Haycock
Parcel # RPRHNDS3070130
Project Details
Residential, one and two family (Any Code mat,
Utility, miscellaneous, private garages (Any Co(
Date
Date Issued:
Issued By:
3,400 SQFT
858 SQFT
SINGLEFAMILY RESIDENTIAL
CITY OF
REXBZJRG City of Rexburg
Amaicz*A►nilyCommunity Department of Community Development
19 E. Main St. / Rexburg, ID. 83440
Phone (208) 359-3020 / Fax (208) 359-3022
Project Information
Permit # 0700028
Permit Type Single Family Residential
Project Name 265 Polo Drive -Haycock
Site Address 265 POLO DR
Parcel # RPRHNDS3070130
Project Description
Names Associated with this Project
-
Type Name Contact
Phone # License # Exp Date
Contractor Nomarco Inc Mason Haycock
208-356-3550 RCE-18628 09/26/2007
Contractor Owner
EXEMPT 12/31/2010
Fixtures
2 - R-Fuel piping fixture or appliance outlet(s) additional
1-
R-Fuel (gas) piping fixture or appliance outlet
1- R-Range hood vents additional
4 -
R-Bath fan vents additional
1- R-Exhaust or vent ducts
1-
R-Furnace / Air Conditioner Combo
- R-Decorative gas -fired appliance(s) additional
1-
R-Dryer vents additional
1 - R-Garbage Disposal
1 -
R-Water Softener
4 - R-Water Closet and/or Urinal
1-
R-Clothes Washing Machine
1 - R-Dish Washer
1-
R-Floor Drain
1- R-Water Heater
6 -
R-Sink (Lavatory, Kitchen, Mop or Bar Sink)
5 - R-Tub and/or Shower Unit
1-
R-Sprinkler
Print Name
Date Issued:
Signature Date
Issued By:
RESIDENTIAL PLAN CHECKLIST
(2003 International Residential Code)
Date: _Z- 7 -0 7
Building Permit Number: 07 000 es
Project: Job Address: ZAPS 46W Fo(e Dr,
Zoning:,l�eZ Number ofStories:� Basement: Yes No in fin. Fixtures: 'ZZ
178Z 2 M��ro b uQQa ammo
Floor Area (sf): _finished, unfinished, J[6gamge Mechanical Fee: 1-15
The following comments based on the 2003 edition of the International Residential Code should be resolved
before a building permit is issued. This correction list is not a building permit. The approval of plans and
specifications does not permit the violation of any section ofthe Intemational Residential Code or any federal,
state or local regulations.
PLAN CHECK
A. Ythfins
To Scale _Legible
/Piot Plan Y &ood Plain
.f--floor / Foundation Plan C
�tion showing cortstoction details S5 y. w f vI
II Building Elevations
Y'--D,sign Criteria (shall be identified on plans as Wind
Cross Calculation Sheets & (2�1oor Joist Details
/Mechanical Design
ZEnergy Calculations (R320 & Ch 11)
85 m.p.h., Snow - 35 lb. Per sq ft.)
B. 'Zoning (circle one -new zoning designations adopted in 2005)
LDRI 12,000 sf min. (width 80 ft. min)
LD 8,000 sf min. (width 60 ft. min); Duplex 10,000 sq. ft. min. with C.U.P.
21,780 sf min. (width 150 ft min) Duplex allowed with C.U.P.
Other (Verify zoning requirements)
C. we
Single Family _Duplex (LDRI only - Conditional use en rmit?l
1-D. S Backs (taken from caves)
nt set back (32 ft. from curb) Ante: 60% min of front yard green
i'*ar set back (LDRI 25 ft. & LDR2 20 ft.)
Sides set backs (6" for every ft. of building height with LDR - 7.5' min., & LDRI - 6' min.)
./Iding-Height (maximum 30 ft.)
E. Footings
doper Size (as per Table 403.1, use 1500 psf unless soil type is known, Table 401.4.1 for soil bearing)
,elf -bar (244 continuous)
ZFooting Depth (36" below finished grade and 12" below undisturbed soil; 18" to top of slab- interior)
F. Fp�ndatiom
/Foundation walls w/ rebar (city ordinance)
.`</2" Anchor Bolts with 2"x 2"x 3/I6" square washers (me], interior bearing walls) R403.1,6.1
Xoundation Drainage (foundations on sift soil shall be designed per R405)
/amp proofing(Waterproofing to finish grade. R406.1 (find, extends 6" min above grade R404.1.6)
—Crawl space access of 18" x 24" min. R408.3 (may differ if mech appliance is in crawl space M1305.1.4)
�Cmwl Space Ventilation/insulation=l sf vent per 150 sf. (with moisture barrier 1 sf. Per 1500 so. ft.) and
within Y ofeach comer (insulate walls vent to inside of home) R408.2
�ading slope away from house. R401.3
G. F,Fnfive
Seismic Hold Downs and Braced Wall Panels (13602.10)
Oloorsjoists sized as per R502.3, Wood I joists sized per manufir.
0oists Under Load Bearing Partitions shall be doubled. R502.4
QGirders sized per R502.5 or per manufr. Tables for engineered products
QCantilevers (comply with R502.3.3 or manuG instruction)
Floor Sheathing (3/4" min for joists 24" oc & 518" forjoists 16" oc) R503.2.2
/<. 1(bearing and nonbearing) stud sizes, height & spacing per Table 602.3(5) R602.3
Headers in Bearing Wall shall be designed as per Tables 502.5(1&2) R602.7
VRoofTrusses(designed according to R802.10.1) 35 g Snow and 90 mph winds (Local Conditions)
After and Truss tie -downs. (R802.10.5)
/c Access 22" x 30" min. opening (R807)
H.,Exterior Covering t
_Masonry and stucco shall have weather resistive barrier over exterior sheathing R703.2 & 703.9.1
f.R f Covering and Ventilation
Roof Ventilation as per R806
/Asphalt Shingles (slope>2:12) w/ ice protection. (Other type: to comply w/ R905._)
I. FJ'�walls
/Garage/House drywall separation (protect ext. walls & beams supporting habitable space) R309.2
Loor from Garage to House (l 318" solid wood or steel door, or 20 min. fire -rated door) 11309.1
—T s, Family Dwelling Separation (1 hr fire separation) Supporting structure also rated. R317.1
---Twin homes & Tmvnhouses (2 hr sepamtion & 4' overbum protection or parapet) R317.2
-One hr walls parallel to and within 3 fl of property line w/ NO openings. R302
Penetrations in previous 3 items to comply with R317.3
K G eral Requirements
use Numbers R321 '
< Half Openable 3sfwindow or Mech. Ventilation in bathrooms, water closets, and similar rooms. R303.3
�terior and exterior stair illumination shall comply with R303.6.
/throe m Fixture clearances comply with Figure R307.2
Zone room at least 120 sf; _Other habitable rooms 70 at. min w/ a min. dimension of 7 ft. R304
•areas w/ sloped ceilings less than 5 f} in height & furred ceilings less than 7ft DO NOT comply
*50%or more of the required area must be at least 7ft high in rooms w/sloped ceiling
I
less clearance from window wells under cantilevered Floors. R310.2
Glazing at Hazardous Locations R308
/'Emergency Egress in all sleeping rooms and basements with habitable space R310
/e required Exit Door shall comply with R311.4
'--�Landings at top and bottom of stairways R311.5.4, and each side of each exterior door. R311.4.3
<ir Ri /Run (7 3/4" max. rise & 10" min. read, nosing req'd if <11")_-Star Width (36" min),
7mirway Headroom (68" min.) Handrails (34"to 38" above stair nosing)(R311.5)
Special conditions for circular, spiral and winder stairways and bulkhead enclosures R311.&S
Stairway Protection (enclosed accessible space under stairs shall be covered with 1/2" drywall) R311.2.2
,elluardrails complying with R312
F Smoke Alarms (each bedroom and common area and one on each eve) (R 313)
L. Energy
_Homes with glazing < 15% of gross area of ext. walls (Townhouses <25%) to comply w/ Chapter 11.
'Otherwise shall meet requirements of/ECC for respective building type. N1101.2
jV apor retarder on warts in winter side of walls, ceiling and floors R31S
/ter Heater heat traps IECC 504.7
/ucl sealing and insulation N1103.3&4 or IECC 503.3.3.3, 503.3.3.4.3
_Plans match quantities & values on a "passing" REScheck compliance report
M. Mechanical
Lu. appliances not in bedrooms, bathrooms, toilet rooms, or storage closets G2406.2
loom access 24" min width/Attic access clear opening 2000/Under floor no. 2200. M1305
Drryer Vent length 25' max w/ 8' transition (-5' per 90 deg turns) M1501.3
Flue chase shown on plans (B-vents not to be inside insulated walls without insulation shield)