Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
SHORT FORM - 07-00012 - 1094 Green Willow Dr - New SFR
Short Form Entire House TRAVIS KAUER ELECTRIC, LLC 10856E 145 N, RIGBV, ID 83442 Phone: 2W313-Ml Fax 208-227-0421 Emit: lraNsaaegida.net Job: 1094 W GREENWILLOW ... Date: Jan 06, 2007 By: TRAMS KAUER ELECTR... 0700012 For: JUSTIN AND NATALIE TAYLOR 1094 Green Willow Dr -Taylor 12939 N 65TH E, IDAHO FALLS, ID 83401 Phone:208-709-5099 Htg Clg Infiltration Outside db (F) -6 89 Method Simplified Inside db (F) 70 75 Construction quality Semi -loose Design TO (F) 76 14 Fireplaces 0 Daily range - H Inside humidity (%) 50 Moisture difference (gr/lb) -31 HEATING EQUIPMENT Make AmStcl Trade Freedom 90 Single Stage Model AUX16080A9421A* Efficiency r 92.1 AFUE` Heating input 80000 Btuhn Heating output Temperature rise 57 F Actual air flow 1139 cfm Air flow factor 0.026 cfm/Btuh Static pressure 0.70 in H2O Space thermostat COOLING EQUIPMENT Make AmStd Trade American Standard 13 Cond 2A7B3030A1 Coil TXA031C4+TAYTXV-3 Efficiency 13 SEER Sensible cooling 21812 Latent cooling 4788 Total cooling 26600 Actual air flow 1139 Air flow factor 0.083 Static pressure 0.70 Load sensible heat ratio 1.00 ROOM NAME Area Mal Htg load (Btuh) Cig load (Btuh) Room1 229 2736 1082 Room2 50 0 0 Room 3 892 8212 942 Room4 204 0 0 Room 5 91 1307 37 Room 6 143 1350 623 Room7 176 2031 644 Room 8 258 4018 1515 Room9 90 1479 353 Room10 40 558 93 Room11 126 2989 1170 Room12 110 2190 1071 Room 13 106 2214 1022 Room14 887 10358 4589 Room15 96 2272 380 Room16 108 1634 212 garage 980 0 0 Printout certified by ACCA to meet all requirements of Manual }C wrtghtsoft RiglFSuite Reslaentlal6.0.79RSR40835 �.. kC9My D=memkWdghtsoft HVACMSTIN AND NATALIETAVLORnp Calc=MJB Onentatlon=N Htg AVF (cfm) 72 0 216 0 34 35 53 106 39 15 79 58 58 272 60 JAN - Btuh Btuh Btuh cfm cfm/etuh in H2O CIg AVF (cfm) 90 0 78 0 3 52 53 126 29 8 97 89 85 381 32 CITY OF REXBURG ;—. Entire House d 4584 43350 13732 1139 1139 Other equip bads 13835 4255 Equip. @ 0.94 RSM 16908 Latent cooling 0 Ynl Al Q e lnn o noon 44on Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wnghtsoft RlghtSu9e R.itlenaa16.0.79RSR40835 2D07Ja"616:49:02 CAMyD=ments\Vynghtsaft HVAC\JUSTIN AND NATALIE TAVLOR.np Cale=MJ8 Onentaaon=N Page Component Constructions Job: 1094WGREENWILLOW ... Date: Jan 06, 2007 Entire House By: TRAVIS KAUER ELECTR... TRAVIS KALIER ELECTRIC, LLC 10856 E 145 N, RIGBY. ID 83442 Phone: 208-313-0081 Fax 208-227-0421 Email: traNstlte@ida.net For: JUSTIN AND NATALIE TAYLOR 12939 N 65TH E, IDAHO FALLS, ID 83401 Phone:208-709-5099 Location: Indoor: Heating Cooling Idaho Falls, ID, US Indoor temperature (F) 70 75 Elevation: 4741 it Design TD (F) 76 14 Latitude: 44 TI Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference (gr/lb) 61.5 -31.5 Dry bulb (F) -6 89 Infiltration: Daily range (F) - 34 (H ) Method Simplified Wet bulb (F) - 60 Constructionqualdy SemHoose Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions Walls 12E-Osw. Wood stud frame, siding or stucco, no board insulation, R-19 cavity insulation 15B11-Owo6: Basement - 8" concrete, wood framing, interiorfinish, R-11 cavity, no board insulation, 6' Partitions 12E-Osvc Wood stud frame, siding or stucco, no board insulation, R-19 cavity insulation Windows 61A: VINYL LOW E, clear; NFRC rated (SHGC=0.31) 1OA-w: French door, wood frame, 1 pane; NFRC rated (SHGC=0.31) Doors 11 DO: Wood door, sdid core, no storm Ceilings 1613-38ad: Ceiling under vented attic, no radiant barrier, dark shingles, R-38 insulation Or Area U-value Insul R Htg HTM Loss Clg HfM Gain (a') (BtuM1V'fl IM-FlBtuh) (BIWA') (Btuh) (BtJM2) (aluh) n 489 0.068 19.0 5.00 2446 0.62 303 ne 37 0.068 19.0 5.17 190 0.64 23 e 459 0.068 19.0 2.46 1129 0.30 140 s 534 0.068 19.0 2.38 1271 0.29 157 w 472 0.068 19.0 3.68 1734 0.45 214 nw 37 0.068 19.0 5.17 190 0.64 23 all 2027 0.068 19.0 3.43 6960 0,42 861 n 544 0.056 11.0 4.93 2681 0.07 38 e 256 0.056 11.0 5.07 1299 0.08 22 s 544 0.056 11.0 4.93 2681 0.07 38 w 240 0,056 11.0 4.91 1178 0.07 16 aN 1584 0.056 11.0 4,95 7840 0.07 113 423 0.068 19.0 5.17 2186 0.07 29 It 83 0.350 0.0 26.6 2201 10.8 893 n 32 0.350 0.0 26.6 851 10.8 345 ne 14 0.350 0.0 26.6 377 23.7 336 s 75 0.350 0.0 26.6 1995 18.8 1413 s 32 0.350 0.0 26.6 851 18.8 603 w 16 0.350 0.0 26.6 426 33.9 543 nw 14 0.350 0.0 26.6 377 23.7 336 all 266 0.350 0.0 26.6 7078 16.8 4469 n 20 0.350 0.0 26.6 532 7.55 151 6 21 0.390 0.0 29.6 622 7.22 152 2889 0.026 38.0 1.31 3772 0.72 2085 A- wnghtsoft RlghtSuite Residenbal6.0.79RSR40635 2007-Mn�0616:49:02 AM C:1My Documents Wrightsoft HVACWUSTIN AND NATALIE TAYLORrrp Calc= MJB Orientation = N Page 1 Floors *Awl 22A-tph: Tile covered slab on grade, heavy moist scil, No edge insul, No hodz insul ' 21A-24t: Tilecovered basement flocr, No Insulation, 24' wide 85 1.358 0.0 0.00 0 0.00 1820 0.025 0.0 1.90 3458 0.00 wnDF7t50ft RlghtSuite Residenda16.0.79RSR40835 2007.ten-0616:49:02 CAMy DmmeneMdghlsot HVAC\JUSTIN AND NATALIE TAVLOR.np Calc=MJB Odentston=N Page Projec ummary ~ Job: 1094 W GREENWILLOW ... Date: Jan Entire House By: TRAMVI KAS KAUER ELECTR... TRAMS KAUER ELECTRIC, LLC 10856E 145 N, RIGBY, ID 83942 Phone: 208.313-0081 Fax 208-227-0421 Emil: tmAS&e@Ida.net For: JUSTIN AND NATALIE TAYLOR 12939 N 65TH E, IDAHO FALLS, ID 83401 Phone:208-709-5099 Notes: Design Information Weather. Winter Design Conditions Outside db -6 F Inside db 70 F Design TO 76 F Heating Summary Structure 43350 Btuh Ducts 0 Btuh Central vent (197 cfm) 13835 Btuh Humidification 0 Btuh Piping 0 Btuh Equipment load 57185 Btuh Infiltration Idaho Falls, ID, US Method Simplified Construction quality SemFloose Fireplaces 0 Heatingg Cooling Area (W) 3604 3604 Volume (" 21658 21658 Airchanges/hour 0.43 0.23 Equiv. AVF (cfm) 155 83 Heating Equipment Summary Make AmStd Trade Freedom 90 Single Stage Model AUX1B080A9421A* Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat Summer Design Conditions Outside db 89 F Inside db 75 F Design TO 14 F Daily range H Relative humidity 50 % Moisture difference -31 gr/lb Sensible Cooling Equipment Load Sizing Structure 13732 Btuh Duds 0 Btuh Central vent (197 cfm) 2549 Btuh Blower 1707 Btuh Use manufacturer's data n Ratetswing multiplier 0.94 Equipment sensible load 16908 Stuh Latent Cooling Equipment Load Sizing Structure 1307 Btuh Duds 0 Btuh Central vent (197 cfm) -3542 Btuh Equipment latent bad 0 Btuh Equipment total bad 16908 Btuh Req. total capacity at 0.82 SHR 1.7 ton Cooling Equipment Summary Make AmStd Trade American Standard 13 Cond 2A7B3030A1 Coil TXA031C4+TAYTXV-3 92.1 AFUE Efficiency 80000 Btuh Sensible cooing 59800 Btuh Latent cooling 57 F Total cooling 1139 cfm Actual air flow 0.026 cfm/Btuh Air flow factor 0.70 in H2O Static pressure Load sensible heat ratio Printout certified by ACCA to meet all requirements of Manual J 8th Ed. 13 SEER 21812 Btuh 4788 Btuh 26600 Btuh 1139 cfm 0.083 cfm/Btuh 0.70 in H2O 1.00 �• wrrgFjtsoft RightSuite Resi6enlal6.0.79RSR40835 2007-Jan-0616:49:02 ACr AC:1My Dewments\Wrightsot HVAC1JUSTIN AND NATALIE TAYLOR.np CaIc=MJ8 Onenta#on=N Page b #: 1094 W GREENWILLOW DR REXB... rformed by TRAVIS KAUER ELECTRIC.. JUSTIN AND NATALIE TAYLOR 12939 N 65TH E IDAHO FALLS, ID 83401 Phone: 208-709-5099 Main flow TRAVIS KAUER ELECTRIC, LLC 10856 E 145 N RIGBY, ID 83442 Phone:208-313-0081 Fax:208-227-0421 travistke@ida.net Scale: 1 : 123 Page 1 Right -Suite Residential 6.0.79 RSR40835 2007-Jar G616:51:55 Documents\Wrightsoft HVAC\J... %ow M 1094 W GREENWILLOW DR REXB... >rmed by TRAVIS KAUER ELECTRIC.. JUSTIN AND NATALIE TAYLOR 12939 N 65TH E IDAHO FALLS, ID 83401 Phone: 208-709-5099 Basement TRAVIS KAUER ELECTRIC, LLC 10856 E 145 N RIGBY, ID 83442 Phone: 208-313-0081 Fax: 208-227-0421 travistke@ida.net Scale: 1 : 123 Page 2 Right -Suite Residential 6.0.79 RSR40835 2007-Jan-06 16:51:55 Documents\Wrightsoft H Duct Sy$tem SummaryJob: 1094WGREENWILLOW... Date: Jan 06, 2007 Entire House By: TRAVIS KAU ER ELECTR... TRAVIS KAUER ELECTRIC, LLC 10856E 145 N, RIGBV, ID 83442 Phone: 203-313-0081 Fac 20&227-0421 Emil: Iramlke@id0.net For: JUSTIN AND NATALIE TAYLOR 12939 N 65TH E, IDAHO FALLS, ID 83401 Phone: 208-709,5099 External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual airflow Total effective length (TEL) Heating 0.70 in H2O 0.34 in H2O 0.36 in H2O 0.20 / 0.16 in H2O 0.067 in/100ft 1139 cfm 536 ft Supply Branch Detail Table Cooling 0.70 in H2O 0.34 in H2O 0.36 in H2O 0.20/0.16 in H2O 0.067 in/100ft 1139 cfm Name Design (Btuh) Htg (cfm) Cig (cfm) Design FR Dlom (in) Rect Size (in) Duct Matt Actual Ln (ft) Ftg.Egv Ln (ft) Trunk Rooms c 1082 72 90 0.090 6 OxO ShMt 18.0 200.0 st2 Rwrn3.A h 4106 108 39 0.112 6 OxO ShMt 10.0 165.0 st1 Root h 4106 108 39 0.068 6 Ox0 ShMt 35.0 255.0 st1B Rooms h 1307 34 3 0.089 6 OxO ShMt 37.0 185.0 st2 Rooms c 623 35 52 0.087 6 OxO ShMt 32.0 195.0 st2 Room? c 644 53 53 0.073 6 OxO ShMt 44.0 225.0 SIM RoomB c 757 53 63 0.100 6 OxO ShMt 16.0 180.0 st2 RoumB-A c 757 53 63 0.097 6 Ox0 ShMt 12.0 190.0 st2 Rooms h 1479 39 29 0.097 6 Ox0 ShMt 8.0 195.0 st2 Rmnll) h 558 15 8 0.073 6 Ox0 ShMt 29.0 240.0 st2 Room11 c 1170 79 97 0.089 6 OXO ShMt 40.0 180.0 st2 Raom12 c 1071 58 89 0.096 6 Ox0 ShMt 31.0 175.0 st1 Rmm13 c 1022 58 85 0.071 6 Ox0 ShMt 42.0 235.0 SIM Room14-A c 1147 68 95 0.077 6 Ox0 ShMt 14.0 240.0 st1A Rmm14 c 1147 68 95 0.069 6 0x0 ShMt 36.0 250.0 st1B Rmmi4-B c 1147 68 95 0.098 6 OxO ShMt 36.0 165.0 st1 Rwm14-c c 1147 68 95 0.069 6 Ox0 ShMt 26.0 260.0 st1B Raom15 h 2272 60 32 0.067 6 OxO ShMt 48.0 245.0 st1B Roomi6 h 1634 43 18 0.074 6 Ox0 ShMt 60.0 205.0 st1B Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam Rect Duct Duct Name Type (cfm) (cfm) FIR (fpm) (in) Size (in) Material Trunk st1 Peak AVF 760 735 0.067 760 13 8 x 18 ShtMetl st1B Peak AVF 347 279 0.067 624 10 8 x 10 ShtMetl st1A st1A Peak AVF 526 512 0.067 592 12 8 x 16 ShtMetl st1 st2 Peak AVF 379 404 0.073 727 10 8 x 10 ShtMetl Return Branch Detail Table Name Grill Size (in) Hog (cfm) Clg (cfm) TEL (ft) Design FIR Veloc (fpm) Dram (in) RectSize (in) StudlJoist Opening (in) Dud Mall Trunk rbl Ox0 411 276 180.0 0.091 650 10 2-14x3.25 2-10x9 SJSp rtl rb2 Ox0 272 381 213.0 0.077 602 10 2-14x3.25 2-10x9 SJSp rtl rb3 Ox0 118 116 243.0 0.067 373 7 14x3.25 10x5 SJSp rtl rb4 Ox0 100 106 189.0 0.086 337 6 140.25 10x5 SJSp rt2 rb5 Ox0 93 105 239.0 0.068 331 6 140.25 10x5 SJSp rt2 rb6 Ox0 144 155 203.0 0.080 490 7 14x3.25 10x5 SJSp rt2 Trunk Htg Clg Design Veloc Diam Rect Dud Dud Name Type (cfm) (Cfm) FIR (fpm) (in) Size (in) Material Trunk rt1 Peak AVF 801 773 0.067 721 14 8 x 20 ShtMetl rt2 Peak AVF 338 366 0.068 659 10 8 x 10 ShtMetl