HomeMy WebLinkAboutRESCHECK - 07-00012 - 1094 Green Willow Dr - New S07 00012
1094 Green Willow Dr -Taylor
REScheck Software Version 3.7.3
Compliance Certifi
Project Title: JUSTIN AND NATALIE TAYLOR
Report Date: 01/06/07
Data filename: C:\Program Files\Check\REScheck\JUSTIN AND NATALIE TAYLOR.rck
Energy Code:
2000 IECC
Location:
Idaho Falls, Idaho
Construction Type:
Single Family
Glazing Area Percentage:
140/6
Heating Degree Days:
7918
Construction Site:
1094 GREENWILLOW DR
REXBURG, ID 83440
Owner/Agent:
JUSTIN AND NATALIE TAYLOR
12939 N 65TH E
IDAHO FALLS, ID 83401
208-709-5099
v L5 U
JAN - 9 2007
10,
rl__REX G
Designer/Contractor:
TRAVIS KAUER ELECTRIC, LLC
TRAVIS KAUER ELECTRIC, LLC
10856 E 145 N
RIGBY, ID 83442
208-313-0081
travistke@ida.net
Compliance: Passes Maximum ILA: 476 Your Home ILA: 382 -> 19.7% Better Than Code (UA)
Wall 1: Wood Frame, 16" o.c.:
576
19.0
0.0
28
Window 2: 10A-w:French door, wood frame, 1 pane; NFRC rated
20
0.350
7
(SHGC=0.31):
Window 1: 61A:VINYL LOW E. clear; NFRC rated (SHGC=0.31):
83
0.350
29
Wall 2: Wood Frame, 16" o.c.:
51
19.0
0.0
2
Window 1: 61A:VINYL LOW E, Gear; NFRC rated (SHGC=0.31):
14
0.350
5
Wall 3: Wood Frame, 16" o.c.:
218
19.0
0.0
13
Wall 4: Wood Frame, 16" o.c.:
342
19.0
0.0
15
Door 1: Solid: -
21
0.350
7
Window 1: 61A:VINYL LOW E, Gear; NFRC rated (SHGC=0.31):
75
0.350
26
Wall 5: Wood Frame, 16" o.c.:
336
19.0
0.0
20
Wall 6: Wood Frame, 16" o.c.:
51
19.0
0.0
2
Window 1: 61A:VINYL LOW E, dear, NFRC rated (SHGC=0.31):
14
0.350
5
Wall 7: Wood Frame, 16" o.c.:
423
19.0
0.0
25
Basement Wall 1: Solid Concrete or Masonry:
576
11.0
0.0
39
Window 1: 61A:VINYL LOW E. clear; NFRC rated (SHGC=0.31):
32
0.350
11
Basement Wall 2: Solid Concrete or Masonry:
256
11.0
0.0
18
Basement Wall 3: Solid Concrete or Masonry:
576
11.0
0.0
39
Window 1: 61A:VINYL LOW E, clear, NFRC rated (SHGC=0.31):
32
0.350
11
Basement Wall 4: Solid Concrete or Masonry:
256
11.0
0.0
17
Window 1: 61A:VINYL LOW E, Gear; NFRC rated (SHGC=0.31):
16
0.350
6
Ceiling 1: Flat Ceiling or Scissor Truss:
1909
38.0
0.0
57
Air Conditioner 1: Electric Central Air: 13 SEER
Furnace 1: Forced Hot AG: 92.1 AFUE
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to
meet the 2000 IECC requirements in
REScheck Version 3.7.3 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
JUSTIN AND NATALIE TAYLOR
Page 1 of 2
Builder/Designer Company Name
Project Notes:
Job Number. 1094 W GREENWILLOW DR REXBURG
1 /-8 1 3,
D to
JUSTIN AND NATALIE TAYLOR Page 2 of 2