Loading...
HomeMy WebLinkAboutCHECKLIST - 07-00011 - 1120 Green Willow Dr - New SFRCITY OF REXBURG America's Family Community SINGLE FAMILY RESIDENTIAL Project Information Permit Type Single Family Residential Site Address 1120 GREEN WILLOW DR Project Description Fee Information City of Rexburg Department of Community Development 19 E. Main St. / Rexburg, ID. 83440 Phone (208) 359-3020 / Fax (208) 359-3022 Project Valuation $189,972.1 f Permit - Electrical 160.00 Mechanical Residential Fixtures 145.00 Building Permit Fee 1,497.75 Plan Check Fee 149.78 Residential Plumbing Permit Fee 208.00 Fire Impact 184.61 Hookup Fee/Sewer I X0.00 Hookup Fee/Water 1,550.00 Park Impact Fee 604.97 Police Impact Fee 158.11 Street Impact Fee 804.25 Water Meter & Parts 317.00 Total Fees Paid $6,779.47 Conditions 1. Unfinished basement Print Name Signature Permit # 0700011 Project Name 1120 Green Willow Dr-Fransen Parcel # RPRWLBE5040040 Project Details Residential, one and two family (Any Code mat - Unfinished Basements (all use group) Utility, miscellaneous, private garages (Any Co( Date Date Issued: Issued By: 1,700 SQFT 1,490 SQFT 615 SQFT C,,, OF SINGLE FAMILY RESIDENTIAL REXBURG City of Rexburg cw- A=Wca' FamdyCommunity Department of Community Development 19 E. Main St. / Rexburg, ID. 83440 Phone (208) 359-3020 / Fax (208) 359-3022 Project Information Permit # 0700011 Permit Type Single Family Residential Project Name 1120 Green Willow Dr-Fransen Site Address 1120 GREEN WILLOW DR Parcel # RPRWLBE5040040 Project Description Names Associated with this Project Type Name Contact Phone # License # Exp Date Contractor Clark Brothers Builders 208-351-5573 RCE-17008 07/11/2007 Contractor Island Park Electric Glade Gunnell 208-390-7150 C-24229 07/01/2007 Contractor Rexburg Plumbing & Heating Dean Moon 208-390-0510 C-10095 11/30/2007 Contractor Rexburg Plumbing & Heating Dean Moon 208-390-0510 C-1416 09/30/2009 Fixtures 1- R-Fuel piping fixture or appliance outlet(s) additional 1 - R-Fuel (gas) piping fixture or appliance outlet 1- R-Range hood vents additional 3 - R-Bath fan vents additional 1- R-Exhaust or vent ducts 1- R-Furnace / Air Conditioner Combo 1- R-Dryer vents additional 1- R-Garbage Disposal 1- R-Water Softener 3 - R-Water Closet and/or Urinal 2 - R-Clothes Washing Machine 1- R-Dish Washer 2 - R-Floor Drain 1- R-Water Heater 5 - R-Sink (Lavatory, Kitchen, Mop or Bar Sink) 4 - R-Tub and/or Shower Unit 1- R-Sprinkler *** SEE ATTACHED CONDITIONS *** Print Name Date Issued: Signature Date Issued By: RESIDENTIAL PLAN CHECKLIST (2003 International Residential Code) Date: 1-1 it D Z Building Permit Number: 01 0C)o ( I Project: Frotv.SeV\, Job Address: 11 ZO 6,ee4- Willow oning:FF=?_ Number of Stories: __L Basement: es No IFi �ffn Fixtures:ZL 1^�mdc uoan1 uyuid pmvia et Floor Area (sf): ISM ❑nished,�unfinished,'�garage Mechanical Fee: f err &&I The following comments based on the 2003 edition of the International Residential Code should be resolved before a building permit is issued. This correction list is not a building permit. The approval of plans and specifications does not permit the violation of any section of the International Residential Code or any federal, state or local regulations. PLAN CHECK A. Plans L[o Scale Legible /11pot Plan yolood Plain /1'Floor/ Foundation Plan LJection showing construction details YAll Building Elevations D��esign Criteria (shall be identified on plans as Wind - 85 m.p.h., Snow - 35 lb. Per sq ft.) //JJ�� �/r. Calculation Sheets loor Joist Delails t eBA SrZeS? /echanical Design Znergy Calculations (R320 & Ch 11) B. Zoning (circle one— new zoning designations adopted in 2005) LDRI 12,000 sf min. (width 80 ft. min) LDR2 8,000 sf min. (width 60 ft. min); Duplex 10,000 sq. ft. min. with C.U.P. 21,780 sf min. (width 150 ft min) Duplex allowed with C.U.P. Other (Verify zoning requirements) �C. U e gle Family _Duplex (LDRI only - Conditional use oermil4) D. Set Backs (taken from eaves) .-4ront set back (32 ft. from curb) Note! 60%min affront yard green X$' /y Prep, ,oO<ear set back (LDRI 25 ft. & LDR2 20 ft.) 41des set backs (6" for every 0. of building height with LDR- 7.5' min., & LDRI - (ymin.) _Building -Height (maximum 30 ft.) EE F tings Proper Size (as per Table 403. 1, use 1500 psf unless soil type is known, Table 401.4.1 for soil bearing) _/bar (244 continuous) Footing Depth (36" below finished grade and 12" below undisturbed soil; 18" to top of slab— interior) F. undation Foundation walls w/ rebar (city ordinance) �/2" Anchor Bolts with 2"x 2"x 3/16" square washers (incl. interior bearing walls) R403.1.6.1 _I'5amndation Drainage (foundations on sift soil shall be designed per R405) Damp proofing/Waterproofing to finish grade. R406.1 (f rd. extends 6" min above grade R404.1.6) -_�rawl space access of 18" x 24" min. R408.3 (may differ if much appliance is in crawl space M 1305.1.4) `mwl Space VentilatioNlnsulation=l sf vent per 150 sf. (with moisture barrier I sf. net 1500 sa. 0.) and within 3' of each comer (insulate walls vent to inside of home) R408.2 /ding slope away from house. R401.3 rame L,Neismic Hold Downs and Braced Wall Panels (R602.10) U 1�a y _Floors joists sized as per R502.3, Wood 1-joists sized per manufr. _Joists Under Load Bearing Partitions shall be doubled. R502.4 _Girders sized per R502.5 or per manufr. Tables for engineered products _Cantilevers (comply with R502.33 or manufr instruction) �or Sheathing (3/4" min for joists 24" oe & 5/8" farjoists 16" oc) R503.2.2 ZWall (bearing and nonbearing) stud sizes, height & spacing per Table 602.3(5) R6023 %/ lieaders in Bearing Wall shall be designed as per Tables 502.5(1&2) R602.7 `Roof Trusses (desived according to R802.10.1) 35 # Snow and 90 mph winds (Local Conditions) ZRatier and Truss tie -downs. (R802.10.5) Attic Access 22" x 30" min. opening (R807) H. tenor Covering Masonry and stucco shall have weather resistive barrier over exterior sheathing R703.2 & 703.9.1 1. Roof Covering and Ventilation ,10loof Ventilation as per R806 LAsphalt Shingles (slope>2:12) w/ ice protection. (Other type: to comply w/ R905.—) I Firewalls ,tf!�Carage/House drywall sepamtion (protect ext. walls & beams supporting habitable space) R309.2 _/Door from Garage to House (1 3/8" solid wood or steel door, or 20 min. fire -rated door) R309.1 —Aso Family Dwelling Separation (1 hr fire separation) Supporting structure also rated. R317.1 —Twin homes & Townhouses (2 he separation & 4' overbum protection or parapet) R317.2 —One fir walls parallel to and within 3 ft of property line w/ NO openings. R302 —Penetrations in previous 3 items to comply with R317.3 K gemiral Requirements ouse Numbers R321 /alf Openable 3sf window or Mech. Ventilation in bathrooms, water closets, and siinilar rooms. R303.3 <nwrior and exterior stair illumination shall comply with R303.6. Bathroom Fixture clearances comply with Figure R307.2 One room at least 120 sf; her habitable rooms 70 sf min w/ a min. dimension of7 R. R304 -areas w/sloped ceilings less than 5 ft in height & furred ceilings less than 7f DO NOT comply *50%or more of the required area must be at least 7ft high in rooms iv/ sloped ceiling gress clearance from window wells under cantilevered Floors. R310.2 Glazing at Hazardous Locations R308 /emergency Egress in all sleeping rooms and basements with habitable space RM0 /c required Exit Door shall comply with R311.4 ,00andings at top and bottom of stairways R311.5.4, and each side of each exterior door. R311.4.3 _Stair Ri / Run (7 3/4" max. rise & 10" min. ad, nosing req'd if <11") air Width (36" min), Stairway Headroom (6' 8" min.) _ andrails (34"to 38" above stair nosingxR311.5) —Special conditions for circular, spiral and winder stairways and bulkhead enclosures R31I.5.8 ___S­Imrway Protection (enclosed accessible space under stairs shall be covered with 1/2" drywall) R311.2.2 Guardrails complying with R312 e-s'atoke Alarms (each bedroom and common area and one on each level) (R 313) I.. Energy _Homes with glazing < 15 % of gross area of ext. walls (Townhouses <25%) to comply w/ Chapter 11. 'Othenrise shall meet requirements offECC jar respective building type. NI101.2 /por retarder on warm in winter side of walls, ceiling and Boors R318 Water Heater heat traps fECC 504.7 Duct sealing and insulation N1103.3&4 or fECC 503.3.3.3, 503.3.3.43 _Plans match quantities & values on a "passing" REScheck compliance report ! M. Mechanical appliances not in bedrooms, bathrooms, toilet rooms, or storage closets G2406.2 /m access 24" min widdi/Attic access clear opening 2000/Under floor r.o. 2200. M1305 Dryer Vent length 25' max w/ 8' transition (-5' per 90 deg turns) M1501.3 0 Flue chase shown on plans (B-vents not to be inside insulated walls without insulation shield)