HomeMy WebLinkAboutCHECKLIST - 07-00011 - 1120 Green Willow Dr - New SFRCITY OF
REXBURG
America's Family Community
SINGLE FAMILY RESIDENTIAL
Project Information
Permit Type Single Family Residential
Site Address 1120 GREEN WILLOW DR
Project Description
Fee Information
City of Rexburg
Department of Community Development
19 E. Main St. / Rexburg, ID. 83440
Phone (208) 359-3020 / Fax (208) 359-3022
Project Valuation
$189,972.1 f
Permit - Electrical
160.00
Mechanical Residential Fixtures
145.00
Building Permit Fee
1,497.75
Plan Check Fee
149.78
Residential Plumbing Permit Fee
208.00
Fire Impact
184.61
Hookup Fee/Sewer
I X0.00
Hookup Fee/Water
1,550.00
Park Impact Fee
604.97
Police Impact Fee
158.11
Street Impact Fee
804.25
Water Meter & Parts
317.00
Total Fees Paid $6,779.47
Conditions
1. Unfinished basement
Print Name
Signature
Permit # 0700011
Project Name 1120 Green Willow Dr-Fransen
Parcel # RPRWLBE5040040
Project Details
Residential, one and two family (Any Code mat -
Unfinished Basements (all use group)
Utility, miscellaneous, private garages (Any Co(
Date
Date Issued:
Issued By:
1,700 SQFT
1,490 SQFT
615 SQFT
C,,, OF SINGLE FAMILY RESIDENTIAL
REXBURG City of Rexburg
cw-
A=Wca' FamdyCommunity Department of Community Development
19 E. Main St. / Rexburg, ID. 83440
Phone (208) 359-3020 / Fax (208) 359-3022
Project Information
Permit # 0700011
Permit Type Single Family Residential
Project Name 1120 Green Willow Dr-Fransen
Site Address 1120 GREEN WILLOW DR
Parcel # RPRWLBE5040040
Project Description
Names Associated with this Project
Type Name Contact
Phone # License #
Exp Date
Contractor Clark Brothers Builders
208-351-5573 RCE-17008
07/11/2007
Contractor Island Park Electric Glade Gunnell
208-390-7150 C-24229
07/01/2007
Contractor Rexburg Plumbing & Heating Dean Moon
208-390-0510 C-10095
11/30/2007
Contractor Rexburg Plumbing & Heating Dean Moon
208-390-0510 C-1416
09/30/2009
Fixtures
1- R-Fuel piping fixture or appliance outlet(s) additional
1 - R-Fuel (gas) piping fixture or appliance outlet
1- R-Range hood vents additional
3 - R-Bath fan vents additional
1- R-Exhaust or vent ducts
1- R-Furnace / Air Conditioner Combo
1- R-Dryer vents additional
1- R-Garbage Disposal
1- R-Water Softener
3 - R-Water Closet and/or Urinal
2 - R-Clothes Washing Machine
1- R-Dish Washer
2 - R-Floor Drain
1- R-Water Heater
5 - R-Sink (Lavatory, Kitchen, Mop or Bar Sink)
4 - R-Tub and/or Shower Unit
1- R-Sprinkler
*** SEE ATTACHED CONDITIONS ***
Print Name
Date Issued:
Signature Date
Issued By:
RESIDENTIAL PLAN CHECKLIST
(2003 International Residential Code)
Date: 1-1 it D Z Building Permit Number: 01 0C)o ( I
Project: Frotv.SeV\, Job Address: 11 ZO 6,ee4- Willow
oning:FF=?_ Number of Stories: __L Basement: es No IFi �ffn Fixtures:ZL
1^�mdc uoan1 uyuid pmvia et
Floor Area (sf): ISM ❑nished,�unfinished,'�garage Mechanical Fee: f err
&&I
The following comments based on the 2003 edition of the International Residential Code should be resolved
before a building permit is issued. This correction list is not a building permit. The approval of plans and
specifications does not permit the violation of any section of the International Residential Code or any federal,
state or local regulations.
PLAN CHECK
A. Plans
L[o Scale Legible
/11pot Plan yolood Plain
/1'Floor/ Foundation Plan
LJection showing construction details
YAll Building Elevations
D��esign Criteria (shall be identified on plans as Wind - 85 m.p.h., Snow - 35 lb. Per sq ft.)
//JJ��
�/r. Calculation Sheets loor Joist Delails t eBA SrZeS?
/echanical Design
Znergy Calculations (R320 & Ch 11)
B. Zoning (circle one— new zoning designations adopted in 2005)
LDRI 12,000 sf min. (width 80 ft. min)
LDR2 8,000 sf min. (width 60 ft. min); Duplex 10,000 sq. ft. min. with C.U.P.
21,780 sf min. (width 150 ft min) Duplex allowed with C.U.P.
Other (Verify zoning requirements)
�C. U e
gle Family _Duplex (LDRI only - Conditional use oermil4)
D. Set Backs (taken from eaves)
.-4ront set back (32 ft. from curb) Note! 60%min affront yard green X$' /y Prep,
,oO<ear set back (LDRI 25 ft. & LDR2 20 ft.)
41des set backs (6" for every 0. of building height with LDR- 7.5' min., & LDRI - (ymin.)
_Building -Height (maximum 30 ft.)
EE F tings
Proper Size (as per Table 403. 1, use 1500 psf unless soil type is known, Table 401.4.1 for soil bearing)
_/bar (244 continuous)
Footing Depth (36" below finished grade and 12" below undisturbed soil; 18" to top of slab— interior)
F. undation
Foundation walls w/ rebar (city ordinance)
�/2" Anchor Bolts with 2"x 2"x 3/16" square washers (incl. interior bearing walls) R403.1.6.1
_I'5amndation Drainage (foundations on sift soil shall be designed per R405)
Damp proofing/Waterproofing to finish grade. R406.1 (f rd. extends 6" min above grade R404.1.6)
-_�rawl space access of 18" x 24" min. R408.3 (may differ if much appliance is in crawl space M 1305.1.4)
`mwl Space VentilatioNlnsulation=l sf vent per 150 sf. (with moisture barrier I sf. net 1500 sa. 0.) and
within 3' of each comer (insulate walls vent to inside of home) R408.2
/ding slope away from house. R401.3
rame
L,Neismic Hold Downs and Braced Wall Panels (R602.10)
U
1�a y
_Floors joists sized as per R502.3, Wood 1-joists sized per manufr.
_Joists Under Load Bearing Partitions shall be doubled. R502.4
_Girders sized per R502.5 or per manufr. Tables for engineered products
_Cantilevers (comply with R502.33 or manufr instruction)
�or Sheathing (3/4" min for joists 24" oe & 5/8" farjoists 16" oc) R503.2.2
ZWall (bearing and nonbearing) stud sizes, height & spacing per Table 602.3(5) R6023
%/
lieaders in Bearing Wall shall be designed as per Tables 502.5(1&2) R602.7
`Roof Trusses (desived according to R802.10.1) 35 # Snow and 90 mph winds (Local Conditions)
ZRatier and Truss tie -downs. (R802.10.5)
Attic Access 22" x 30" min. opening (R807)
H. tenor Covering
Masonry and stucco shall have weather resistive barrier over exterior sheathing R703.2 & 703.9.1
1. Roof Covering and Ventilation
,10loof Ventilation as per R806
LAsphalt Shingles (slope>2:12) w/ ice protection. (Other type: to comply w/ R905.—)
I Firewalls
,tf!�Carage/House drywall sepamtion (protect ext. walls & beams supporting habitable space) R309.2
_/Door from Garage to House (1 3/8" solid wood or steel door, or 20 min. fire -rated door) R309.1
—Aso Family Dwelling Separation (1 hr fire separation) Supporting structure also rated. R317.1
—Twin homes & Townhouses (2 he separation & 4' overbum protection or parapet) R317.2
—One fir walls parallel to and within 3 ft of property line w/ NO openings. R302
—Penetrations in previous 3 items to comply with R317.3
K gemiral Requirements
ouse Numbers R321
/alf Openable 3sf window or Mech. Ventilation in bathrooms, water closets, and siinilar rooms. R303.3
<nwrior and exterior stair illumination shall comply with R303.6.
Bathroom Fixture clearances comply with Figure R307.2
One room at least 120 sf; her habitable rooms 70 sf min w/ a min. dimension of7 R. R304
-areas w/sloped ceilings less than 5 ft in height & furred ceilings less than 7f DO NOT comply
*50%or more of the required area must be at least 7ft high in rooms iv/ sloped ceiling
gress clearance from window wells under cantilevered Floors. R310.2
Glazing at Hazardous Locations R308
/emergency Egress in all sleeping rooms and basements with habitable space RM0
/c required Exit Door shall comply with R311.4
,00andings at top and bottom of stairways R311.5.4, and each side of each exterior door. R311.4.3
_Stair Ri / Run (7 3/4" max. rise & 10" min. ad, nosing req'd if <11") air Width (36" min),
Stairway Headroom (6' 8" min.) _ andrails (34"to 38" above stair nosingxR311.5)
—Special conditions for circular, spiral and winder stairways and bulkhead enclosures R31I.5.8
___SImrway Protection (enclosed accessible space under stairs shall be covered with 1/2" drywall) R311.2.2
Guardrails complying with R312
e-s'atoke Alarms (each bedroom and common area and one on each level) (R 313)
I.. Energy
_Homes with glazing < 15 % of gross area of ext. walls (Townhouses <25%) to comply w/ Chapter 11.
'Othenrise shall meet requirements offECC jar respective building type. NI101.2
/por retarder on warm in winter side of walls, ceiling and Boors R318
Water Heater heat traps fECC 504.7
Duct sealing and insulation N1103.3&4 or fECC 503.3.3.3, 503.3.3.43
_Plans match quantities & values on a "passing" REScheck compliance report !
M. Mechanical
appliances not in bedrooms, bathrooms, toilet rooms, or storage closets G2406.2
/m access 24" min widdi/Attic access clear opening 2000/Under floor r.o. 2200. M1305
Dryer Vent length 25' max w/ 8' transition (-5' per 90 deg turns) M1501.3
0 Flue chase shown on plans (B-vents not to be inside insulated walls without insulation shield)