Loading...
HomeMy WebLinkAboutJOIST - 08-00446 - 544 Woodbridge St - New SFRfrom above 2x4 minimum squash blocks OUse 2x4 minimum squash blocks CS to transfer load around TJI® joist Web stiffeners Se diameter maximum hole for required each lit 20 Side at EIW /8a deep blocking paw' 6" diameter maximum for blocking panels 9' " deep or shorter than 12" long. be not cut flanges. Filler block: Attach with ten 10d (3") box trails, clinched. Use ten 16d (3)'2') box nails from each side with 3)'2" TJP joist flange widths. Use fifteen nails with TJI® joist depths greater than 16". board Install (tight to bottom flange with face mount hangers). Attach with ten 10d (3") box nails, clinched when possible. Backer block both skies of web with single TJI* joist WARNING Joists are unstable until braced laterally Bracing Includes: • Blocking • Sheathing • Hangars • Rim Stuart DO NOT allow workers • stat tined • Rim Joist to walk on joists until braced. INJURY MAY RESULT. A complete TJ-Xpert® framing plan requires the iLevel® Framer's Pocket Guide See Level® Framer's Pocket Guide for Product Trademark Information A3 A3 CS SYSTEM WARNINGS \[/ Do not splice Parallel Closure less than V three times the cantilever length from face of cantilever's support. 3 Skew cut joist ends at all skewed support locations. is DO NOT stack building materials on unsheathed joists. Stack only over beams or walls. WARNING NOTES: Lack of concern for proper bracing during construction can result in serious accidents. Under normal conditions if the following guidelines are observed, accidents will be avoided. I . All blocbng, hangars, ran boards and rim joists al the end supppns df the TJI 6 jo'ets must be mmpletay mefelled and properly nadwi 2. Lateral strength like a braced! end wall or an exhaling deck. must be established at the arks of the bay. This can also he accomplished by a temporary or permanent deck (standing) fastened to the first 4 feet officiate at the end of Me bay. 3. Sa Sty bredng Imes of txb handl ddr, must be nailed to a braced aM well w sheathed a,ea as In is 2 and to Saul joist. Widout this br"cng, buckling akeweys or rollover is highly probable under IgM tOpetuMbn bads. IN. a warker or one layer of ter sled sheathing. 4. SMaNilq must be totally anechad to each TJI °I joist before additional Ideas can be placed to the system. 5. Ends of cantilevers ragtime safety bracing on both Me top and Whom fanged. b. The flanges must remain straight within a utterance of Y' tram true signmaM. NAILING REQUIREMENTS TJI®foists at bearings: Two 8d (2Y") box nails (1 each side), 1 Y" minimum from end. Blocking panels, rim joist or rim board to (Tearing plate: Td10 blocking panels or rim joist. 1 Od (3") box nails at 6" o.c. Trus Joist rim board: Toenail with 10d (3") box nails at 6" o. c. or 16d (3Y") box nails at 12" o.c. Shear transfer. Connections equivalent to decking nail schedule Rim board, rim joist or closure to TJI0 joist: 13/a" width or less: Two 1 Od (3") box nails, one each at top and bottom flange. 2%5"thru 2%/2" widths: Two 16d (V22") box nails, one each at top and bottom flange. 3%2" width: Toenail joist to rim joist with one 10d (3") box nail each side of joist top flange. 2x4 minimum squash blocks: Two 10d (3") box nails, one each at top and bottom flange. Plot ID Qty Product Label Top Nails Face Nails Member Nails Notes HI 6 IUSI.81/11.88 H2 1 U410 Harger Notes: (2) Web -Stiffeners Required (5) Backer Blocks Required 10-NIO (5) 14-10d 6-20d (20) 2 CREATED BY Stock Building Supply 671 So.Yellowstone Rexburg, ID 83440 (208) 356-4626 FAX: (208) 356-4508 LEVEL NOTES File Name: rex 9 kevin whisperwood hirtle.JOB Level Name: main floor Plotted: 9/16/2008 09:38 Design Status: main floor.. --- 9/16/2008 09:16 roof framing ... 9/16/2008 09:09 NOTE: Level design times indicated above provide assurance for {proper level stacking. Design Methodology: ASD Floor Area Loading Is: 40psf Live Load and 15 psf Dead Load Maximum Joist Deflection: L/480 Live Load 11240 Total Load TJ -Pro Rating Information: Weighted Average: 41 Lowest Rating: 38 Highest Rating: 67 Glued d Nailed Decking is Required Direct Applied Ceiling is Not Required Floor Decking: 23/32" Panels (24" Span Rating) Normal O.L. Spacing = 16"` *Unless noted otherwise Scale: 3116" = 1r LMT pert SEF' 1 7 20 SYMBOL LEGEND Point Load Line Load Area Load Detail Callout Label (See Framer's Pocket Guide) .� Required Bearing Length in inches (Adequate bearing has been provided if bearing length is not indicated.) 1 of 2 FOR THE TJ-XPERT WARRANTY SEE FRAMER'S POCKET GUIDE Preliminary Layout for Review and Approval TJ -%pert 6.45 (#684( C6.45 11156.45 Pli JOIST AND BEAM LIST Plot ID Length Product Plies Qty A48 48' 11 7/8" TJI 110 joist 1 5 A46 46' 11 7/8" TJI 110 joist 1 2 A42 42' 11 7/8" TJI 110 joist 1 5 A38 38' 11 7/8" TJI 110 joist 1 I A36 36' 11 7/8" TJI 110 joist 1 6 A34 34' 11 7/8" TJI 110 joist 1 12 A32 32' 11 7/8" TJI 110 joist 1 4 A24 24' 11 7/8" TJI 110 joist 1 2 A14 14' 11 7/8" TJI 110 joist 1 3 Al2 12' 11 7/8" TJI 110 joist 1 1 A8 8' 11 7/8" TJI 110 joist 1 2 A6 6' 11 7/8" TJI 110 joist 1 5 B6 6' 11 7/8" TJI 110 joist 2 2 MI 56' 1 3/4" x 9 1/2" 1.9E Microllam LVL 3 3 111 16' 1 3/4" x 9 1/2" 1.9E Microllam LVL 2 4 M3 14' 1 3/4" x 9 1/2" 1.9E Microllam LVL 4 4 ACCESSORIES LIST Bbl 1 5/8" or 3/4" Backer Blocks 1 14 Wb1 6 7/8" 5/8" x 2 5/16" Web Stiffeners 2 4 Rml 16' 1 1/4" x 11 7/8" 1.3E TimberStrand LSL 1 14 Pct 4' 9 11/16" 11 7/8" TJI 110 joist 1 1 Bkl 1' 2 1/4" 11 7/8" TJI 110 Blocking Panels 1 9 Ski- 6' 7 5/8" 11 7/8" TJI 130 Blocking Panels 1 1 Shl 4' At 8' 23/32" Panels (24" Span Rating) 1 63 Bk*, Random length blocking panel cuts I Bk, Blocking Panels: Rm, Rim Board: Pc, Parallel Closure 2 CREATED BY Stock Building Supply 671 So.Yellowstone Rexburg, ID 83440 (208) 356-4626 FAX: (208) 356-4508 LEVEL NOTES File Name: rex 9 kevin whisperwood hirtle.JOB Level Name: main floor Plotted: 9/16/2008 09:38 Design Status: main floor.. --- 9/16/2008 09:16 roof framing ... 9/16/2008 09:09 NOTE: Level design times indicated above provide assurance for {proper level stacking. Design Methodology: ASD Floor Area Loading Is: 40psf Live Load and 15 psf Dead Load Maximum Joist Deflection: L/480 Live Load 11240 Total Load TJ -Pro Rating Information: Weighted Average: 41 Lowest Rating: 38 Highest Rating: 67 Glued d Nailed Decking is Required Direct Applied Ceiling is Not Required Floor Decking: 23/32" Panels (24" Span Rating) Normal O.L. Spacing = 16"` *Unless noted otherwise Scale: 3116" = 1r LMT pert SEF' 1 7 20 SYMBOL LEGEND Point Load Line Load Area Load Detail Callout Label (See Framer's Pocket Guide) .� Required Bearing Length in inches (Adequate bearing has been provided if bearing length is not indicated.) 1 of 2 FOR THE TJ-XPERT WARRANTY SEE FRAMER'S POCKET GUIDE Preliminary Layout for Review and Approval TJ -%pert 6.45 (#684( C6.45 11156.45 Pli