HomeMy WebLinkAboutTRUSSES - 08-00373 - 331 Jefferson Dr - New SFRN
0 N
W 0
N
0
'TO -1 A
TO -1
G E 0 -1
3MC W-E_ST TRIJ=SS_PLA�_T__
715 Bombardier Name: Truss transferred from Layout
'aho Falls, Id Address: Job:
3402
N 0 r
0 0 0 ^
0�
JOI
J03
J05
JO5
r
JO3
N r
0
N
�7
rJO�
0 0
0
0
01:�\
j Job Truss Truss Type Qty ' Ply - - -
I
807142-08 T03 " "'MMON 7
Reference optional) _
'BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 0 s Jan 3 2008 MiTek Industries, Inc. Mon Jul 21 16.36:34 2008 Page 1
-1-0-0+ ----6-6-0 - - 13-0-0 - i 19-&0
1-0-0 6-6-0 6-6-0 6-6-0
51b 1,0120 =_
0
7.00112
T2
-Tz
54?A1120:
-
'-
W1
W1
W2
i
1 J
K H
$iiB M1120
SSA W20 -
536 41020=
_ 26-0-o - - - -- --
6-6-0 1-0-0
Sub = 1:44.0
W2
tr
r
Sib U1120=
8-8-0 17-4-0 26-M I
8-8-0 8-8-0 8-8-0
Plate Offsets_(X,Y): [8:0-1-3,Edge], [C 0-3-00-3-4], [E:073-0,0-3-4], [F.0-1-3,Edgej, (1-1:04-0,0-3-0], [I:0-4-010-3-0]—
LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) Well Ud PLATES GRIP
TCLL 35.0 Plates Increase 1.15 TC 0.53 Vert(LL) -0.31 H-1 >985 360 M1120 197/144
TCDL 7.0 Lumber Increase 1.15 BC 0.65 Vert(TL) -0.42 H-1 >737 240
BCLL 0.0 Rep Stress Incr YES WB 0.45 Horz(TL) 0.07 F n/a nla
BCDL 7.0 Code IRC2006ITP12002 (Matrix) Wind(LL) 0.07 B-I >999 240 Weight: 961b
LUMBER BRACING
TOP CHORD 2 X 4 SPF 165OF 1.5E TOP CHORD Structural wood sheathing directly applied or 4-3-10 oc pudins.
BOT CHORD 2 X 4 SPF 165OF 1.5E BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2 X 4 SPF Stud/Std
REACTIONS (lb/size) B=1445/0-5-8, F=1445/0-5-8
Max Horz B=-242(LC 3)
Max UpliftB=-329(LC 5). F=-329(LC 6)
FORCES (lb) - Maximum Compression/Maximum Tension
TOP CHORD A-B=0/45. B-C=-2179/406, C-D=-1910/435, D-E=-1910/435, E-F=-2179/406, F-G=0/45
BOT CHORD B-1=-34311754, 1-J=-11611181, J-K=-116/1181, H-K=-116/1181. F-H=-234/1754
WEBS C-1=4761266. D-1=-184/744, D-H=-184/744, E-H=476/266
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; h=25ft; TCDL=4.2psf, BCDL=4.2psf; Category 11; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 240-0 wide will fit between the bottom chord and any other members.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 329 lb uplift at joint B and 329 lb uplift at joint F.
6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job - - - Truss trussTypo Qty Ply - - --
B07142-08 i T02 COMM 2 1
Job ice (optional)
BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 _ v 7.030�n 3 2008 MiTek Industries, Inc. Mon Jul 21 16:36:33 2008 Page 1
— -1-0-0 - -- 4-6-0 - - - - - - - 9-0-0 10-0-0 - { -- ----- ------
1-0-0 4-6-0 4-6-0 1-0-0
scak _ 1:17.6
4*0 Mn20 -
c
7.00[
F
1 Sad M112011
E i$
3A MI120= Sad MUM=
4-6-0 -- - 9-0-0 {
4-6-0 4-6-0
LOADING (psf) j SPACING 2-0-0 CSI DEFL in (loc) Vdefl Ud PLATES GRIP
TCLL 35.0 Plates Increase 1.15 TC 0.29 Vert(LL) -0.01 B-F >999 360 M1120 197/144
TCDL 7.0 Lumber Increase 1.15 BC 0.15 Vert(TL) -0.02 B-F >999 240
BCLL 0.0 Rep Stress Incr YES WB 0.10 Horz(TL) 0.00 D n/a n/a
BCDL 7.0 Code IRC2006lrP12002 (Matrix) Wind(ILL) 0.00 F >999 240 Weight: 28lb
LUMBER BRACING
TOP CHORD 2 X 4 SPF 165OF 1.5E TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2 X 4 SPF 165OF 1.5E BOT CHORD Rigid ceiling directly applied or 10-M oc bracing.
WEBS 2 X 4 SPF Stud/Std
REACTIONS (Ib/size) B=528/0-5-8, D=528/0-5-8
Max Horz B=-86(LC 3)
Max UpliftB=-157(LC 5), D=-157(LC 6)
FORCES (lb) - Maximum Compression/Maximum Tension
TOP CHORD A-8=0/45, B-C=-478/71, C-D=-478/70, D-E=0/45
BOT CHORD B-F=0/317, D-F=0/317
WEBS C-F=0/179
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; h=25ft; TCDL=4.2psf; BCDL=4.2psf; Category It: Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) . This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-&0 tall by 240-0 wide will fit between the bottom chord and any other members.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 157 lb uplift at joint B and 157 lb uplift at joint D.
6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSIlTPI 1.
LOAD CASE(S) Standard
Job - - - - j Truss ; Truss Type --- f oty Ply
B07142-08 T01 D ' RMON 3
__ _ _ _ r Reference (optional)
�BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 � `�30 s Jan 3 2008 MTek Industries, Inc. Mon Jul 21 16:36:32 2008 Page 1
-1-0-0 7-1-0 14-2-0 21-3-0 2874-0 35-5-0 42-6-0 43-67?0
1-0-0 7-1-0 7-1-0 7-1-0 7-1-0 7-1-0 7-1-0 1-0-0
Scale - 1*69-7
5.4 M1120
EI`
7.60'12 -'i:{ 1
T3.. �\
Sag M1120 54 M1120 :
w1 w1
72
ry
54 M1120
' � SaS M1120�
w3 w2 w2 W3
W4 W4'
Tf
N I 1
.-�-6s2 _._ - _.-_ --.62_
H
y __�-
- Sdi MII20=- M N 0 L P a K R S J
7a8 M1120 - 5a6 M020 6021NA120- 6a12M020= 54 MI120-
56 A4120`
MM1120 -
8-6-0 _ - - 17-0-0 25-6-0 34-070 42-6-0
8-6-0 8-6-0 8-6-0 8-6-0 8-6-0
Plate Offsets (X,Y) [B:0 1-3 Edge]�[B:g17-5,0-1-0], [C:0-4-0,0-3-0],_[DX 4-0,0-3-0],LF.0-4-0 0-3-0 , [G:0-4 0,0-3-0J, [H:0-7-5,0-1-0]�[H_0-1-3,Edgq] [ -.q+0,(-3-4], [M:0-4-0,0-3-4
LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) Well Ud PLATES GRIP
TCLL 35.0 Plates Increase 1.15 TC 0.75 Vert(LL) -0.45 L-M >999 360 M1120 197/144
TCDL 7.0 Lumber Increase 1.15 BC 0.88 Vert(TL) -0.66 K-L >767 240
BCLL 0.0 Rep Stress Incr YES WB 0.76 Horz(TL) 0.21 H n/a n/a
BCDL 7.0 I Code IRC20061TPI2002 (Matrix) Wind(LL) 0.15 K-L >999 240 Weight:194 lb
LUMBER BRACING
TOP CHORD 2 X 4 SPF 165OF 1.5E TOP CHORD Structural wood sheathing directly applied or 2-5-14 oc purlins.
BOT CHORD 2 X 4 SPF 165OF 1.5E BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing, Except:
WEBS 2 X 4 SPF Stud/Std 8-7-12 oc bracing: B-M.
WEDGE WEBS 1 Row at midpt D-L, E-L, E-K, F-K
Left: 2 X 8 DF SS, Right: 2 X 8 DF SS
REACTIONS (lb/size) B=2462/0-5-8, H=2462/0-5-8
Max Horz B=393(LC 4)
Max UptiftB=-498(LC 5), H=-498(LC 6)
FORCES (lb) - Maximum Compression/Maximurn Tension
TOP CHORD A-13=0/45, B-C=-4107/719, C-D=-3897/803, D-E=-3064/691, E-F=-3064/691, F-G=-3897/803, G-H=4107/719, H-1=0/45
BOT CHORD B-M=-663/3391, M-N=-431/2804, N-0=-431/2804, L-0=-431/2804, L-P=-188/2121, P-Q=-188/2121, K-Q=-188/2121, K-R=-318/2804, R-S=-318/2804, J-S--31812804, H-J=-485/3391
WEBS C-M=463/282, D-M=-243/782, D-L=-896/410, E-L=-332/1261, E-K=-332/1261, F-K=-896/410, F-J=-243/782, G-J=463/282
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; h=25ft; TCDL=4.2psf; BCDL=4.2psf; Category II: Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed : Lumber DOL=1.33 plate grip DOL=1.33.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord
and any other members.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 498 lb uplift at joint B and 498 lb uplift at joint H.
6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job - - -- - ' Truss - -- Truss Type - -- ---
807142-08 TO1 C i COMM
BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
Qty ply
Job n_ce (optional)_ -- -
7A30n 3 2008 M'iTek Industries, Inc. Mon Jul 21 16:36:31 2008 Page 1 -
-- -- 7-1-0
7-1-0
14-2-0 21-3-0 28-4-0
7-1-0 7-1-0 7-1-0
701
U10 W118H-
D
35-5-0
7-1-0
42-&0 1
7-1-0
Scab - 1:68.8
56MI120 :-
j Sfm MII20�
C i E
Wti/ % W1
534 M020 `\
. .. USM1120�
�- W3 W2 W2 W3
WI W4 \
82 — - -- g2. — Wr
ir.
5x6 M1120 = K L M J N O 1 P O H 50 MII20==
7d M1120-- 54 M1120" GA MIIN= GO MM- 5x8M1120-- 7)4611120
8-&0 - - { — 17-0-0 I 25-&0-- i 34-0-0 - 42-&0 }
8-6-0 8-6-0 8-6-0 8-6-0 8-6-0
Plate Offsets (X,Y)_[A 0.1-3,Edge], [A.0-7-5,04q,- [B:0-4-0.0-3-0]. [C O O,Ov3-0�,_ E[v:F4-0,0-3-O , [F:0-4-0,0-3.0], W-5,04q. [G:0-1-3.Edge1, [HA-4-0,0-3-4]. [K-"70.0-3-4
- — - 1
-
`LOADING (psf) — SPACING 2-0-0 i CSI -- DEFL in (loc) Well Ud Iv- -� PLATES GRIP - - - - -
TCLL 35.0 Plates Increase 1.15 TC 0.79 Vert(LL) -0.44 J-K >999 360 MI120 197/144
TCDL 7.0 Lumber Increase 1.15 BC 0.88 Vert(TL) -0.66 I-J >760 240 MI118H 141/138
BCLL 0.0 Rep Stress Incr YES WB 0.76 Horz(TL) 0.21 G n/a n/a
BCDL 7.0 Code IRC2006/TPI2002 (Matrix) Wind(ILL) 0.15 A-K >999 240 Weight:191 lb
LUMBER BRACING
TOP CHORD 2 X 4 SPF 1650F 1.5E TOP CHORD Structural wood sheathing directly applied or 2.4-0 oc puriins.
BOT CHORD 2 X 4 SPF 165OF 1.5E BOT CHORD Rigid ceiling directly applied or 8-4-7 oc bracing.
WEBS 2 X 4 SPF Stud/Std WEBS 1 Row at midpt C-J, D-J, D-1, E-1
WEDGE
Left: 2 X 8 DF SS, Right: 2 X 8 DF SS
REACTIONS (lb/size) A=2353/0.5.8, G=2353/0-5-8
Max HorzA=390(LC 3)
Max UpliftA=433(LC 5), G=433(LC 6)
FORCES (Ib) - Maximum CompressiordMaximum Tension
TOP CHORD A-B=-41261732, B-C=-3918/816, C-D=-3072/695, D-E=-3072/695, E-F=-3918/817, F-G=4126/732
BOT CHORD A-K=-689/3411, K-L=-449/2813, L-M=-449/2813, J-M=-449/2813, J-N=-204/2127, N-0=-204/2127,1-0=-204/2127,1-P=-33512813, P-Q=-335/2813, H-Q=-33512813, G-H=-532/3411
WEBS B-K=470/287, C-K=-255/798, C-J=-901/414, D-J=-334/1265, D-I=-334/1265, E-1=-901/414, E-H=-2551798, F-H=470/287
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; h=25ft; TCDL=4.2psf; BCDL=4.2psf; Category II; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) All plates are MT20 plates unless otherwise indicated.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord
and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 433 lb uplift at joint A and 433 Ito uplift at joint G.
7) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job - Truss Truss Type Qty Ply - — - - --
B07142-08 iT01B "`4MON 7 t
Reference optional),__ _
BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 0 s Jan 3 29D8 MMiTek Industries, Inc. Mon Jul 21 16:36:30 2008 Page 1
-11-0-0 7-1-0_ } 14-2-0 -+— 21-3-0 28-4-0 35-5-0 42-&0
1-0-0 7-1-0 7-1-0 7-1-0 7-1-0 7-1-0 7-1-0
Scab* 169,6
54 K9120 =
E
7 00 12
5K9Mt120'-
.j:
Df'
I
W1' Wt
54 M020
W3 W2 W
wn
82
Sid M1120 L M N K O P J c
7S M1120 = 54 MI120 - GM 2 ba120= 602 0120 -
5A M1120.�
5r8 M1120— 7,8 M020=
8-6-0 17-0-0- 25-6-0 34-0-0 42-6-0
8-6-0 8-6-0 8-6-0 8-6-0 8-6-0
Plate Offsets (X,Y)B:0-1-3,Edge], [B:0-7-5,0-1-0], [C:0-4-0,0-3-0 L:0-4-0,0-3.0),_[F:0-4-0,0-3-Oj, LG-.0-4-0,0-3-0], H:0-7-5.0-1-0], H:0[ 1-3,Edge], [I:0-40,0-3-4], [L 0-4_0,0-3-4]
LOADING (psf) SPACING 2-" CSI DEFL in (loc) Vdefl Ud PLATES GRIP
TCLL 35.0 Plates Increase 1.15 TC 0.79 Vert(LL) -0.45 K-L >999 360 M1120 197/144
TCDL 7.0 Lumber Increase 1.15 BC 0.88 Vert(TL) -0.66 J-K >763 240
BCLL 0.0 Rep Stress lncr YES WB 0.76 Horz(TL) 0.21 H rVa n/a
BCDL 7.0 Code IRC20061TP12002 (Matrix) Wind(LL) 0.15 H-1 >999 240 Weight: 193lb
LUMBER BRACING
TOP CHORD 2 X 4 SPF 165OF 1.5E TOP CHORD Structural wood sheathing directly applied or 24-0 oc purlins.
BOT CHORD 2 X 4 SPF 165OF 1.5E BOT CHORD Rigid ceiling directly applied or 8-6-11 oc bracing.
WEBS 2 X 4 SPF Stud/Std WEBS 1 Row at midpt D-K, E-K, E-J, F-J
WEDGE
Left: 2 X 8 DF SS, Right: 2 X 8 DF SS
REACTIONS (lb/size) B=2464/0-5-8, H=2351/0-5-8
Max Horz. B=402(LC 4)
Max UpliftB=499(LC 5), H=432(LC 6)
FORCES (lb) - Maximum Compression/Maximum Tension
TOP CHORD A-B=0145, B-C=41101720, C-D=-3901/803, D-E=-3068/692, E-F=-30691694, F-G= 3915/816, G-H=41231731
BOT CHORD B-L=-67713394, L-M=445/2807, M-N=445/2807, K-N=445/2807, K-O=-20212124, O-P=-202/2124, J-P=-202/2124, J-Q=-333/2810, Q-R=-333/2810, I-R=-33312810, H-1=-531/3408
WEBS C-L=4631282, D-L=-2431782, D-K=-896/410, E-K=-332/1261, E-J=-33411265, F-J=-9011414, F-1=-255/798, G-1=470/287
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; h=25ft; TCDL=4.2psf; BCDL=4.2psf; Category 11. Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) ' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-&0 tall by 2-0-0 wide will fit between the bottom chord
and any other members.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 499 lb uplift at joint B and 432 lb uplift at joint H.
6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSIf rPI 1.
LOAD CASE(S) Standard
1$
Job - i Truss Truss Type - QtyPly --- - - - - -- -
B07142-08 TWA - - -- COM) - - - -' —+ 1J.- 1 -
1 _ I_ _ __ _ JobL Jnce(optional)
BMC WEST (IDAHO FALLS), IDAHO FFALLS, ID 83402 7.03 n 3 2008 MTek Industries, Inc. Mon Jul 21 16:36:28 2008 Page 1
-11-0-� 7-1-0 i- 14-2-0 21-3-0 28-4-0 35-5-0 42-6-0
1-0-0 7-1-0 7-1-0 7-1-0 7-1-0 7-1-0 7-1-0
stela - 1:69-6
7x10M111eH=
i/
54 M1120= IA L N K O P J 1
1.5x4 M1120 11 596 MI12D- 64 M1120 = 6x12 MI120 - 1.5A M1120'
TS,
5,5 MI120=
7-1-0 - -- -
14-2-0 --
+ - 21-3-0
i --
30-9-4
36-7-10 } A _ 42-6-0 - --
7-1-0
7-1-0
7-1-0
9-6-4
5-10-6 5-10-6
Plate Offsets (X,Y): (B:0.1-B,Ed gej [C;0-4�-0-0 0.3-0],
[D_0-4-0 0-3-0]. [F:0-3-4.Edge], [G:0-5-0,0.3-4], [H:0-1-3 Edge]. [K:0-4-0,0.3-4 , L:0-3-0.0-3-0
LOADING (psf) SPACING
2-0-0
CSI
DEFL in (loc) I/defl L/d
PLATES GRIP
TCLL 35.0 ; Plates Increase
1.15
TC 0.66 j
Vert(LL) -0.28
J-K >999 360
M1120 197/144
TCDL 7.0 Lumber Increase
1.15
BC 0.68
Vert(TL) -0.46
J-K >805 240
i
M1118H 141/138
BCLL 0.0 Rep Stress Ina
YES
WB 1.00
Horz(TL) 0.06
J n1a Na
BCDL 7.0 Code IRC2006/fP12002
i
(Matrix) 1
Wind(LL) 0.08
B-M >999 240
Weight: 188lb
LUMBER
BRACING
TOP CHORD 2 X 4 SPF 165OF 1.5E
TOP CHORD
Structural wood sheathing directly applied or 3-9-10 oc pudins.
BOT CHORD 2 X 4 SPF 165OF 1.5E
BOT CHORD
Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 2 X 4 SPF Stud/Std
WEBS
1 Row at midpt
C-L, D-K, F-J
REACTIONS (lb/size) B=1579/0-5-8, J=2772/0-5.8, H=228/0.5-8
Max Horz B=402(LC 4)
Max UpliftB=-366(LC 5). J=-500(LC 6), H=-111(LC 9)
Max Grav B=1579(LC 1), J=2772(LC 1). H=373(LC 10)
FORCES (Ib) - Maximum Compression/Maximum Tension
TOP CHORD A-B=0/45, B-C=-2414/459, C-D=-1724/380, D-E=-983/320, E-F=-987/325, F-G=-88/773, G-H=-350/388
BOT CHORD B-M=452/1944, L-M=453/1942, L-N=-232/1353, K-N=-23211353, K-O=-381175, O-P=-38/175, J-P=-38/175, I-J=-3151164, H-1=-305/186
WEBS C-M=0/261, C-L=-682/283, D-L=-88/537, D-0-1008/373, E-K=-1091324, F-K=-137/1014, F-J=2179/454, G-J=-626/301, G-1=0/193
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; h=25ft; TCDL=4.2psf; BCDL=4.2psf; Category 11; Exp C; enclosed; MWFRS (tow -rise) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) All plates are MT20 plates unless otherwise indicated.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-" tall by 2-0-0 wide will 5t between the bottom chord
and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 366 lb uplift at joint B. 500 lb uplift at joint J and 111 lb uplift at joint H.
7) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job — - j Truss - - -- - —- 'Truss Type -- (]ty — -Ply
607142-08 IT01 r ''MON 1 1
---_ -- -- _-. -- -- .-_ J_ .geference (optional)-
hMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 �Ef0 s Jan 3 2008 MTek Industries, Inc. Mon Jul 21 16:36:27 2008 Page 1
-,1-0-0 7-1-0 i 14-2-0 21-3-0 284-0 35-5-0 42-6-0 4,3-6-p
1-0-0 7-1-0 7-1-0 7-1-0 7-1-0 7-1-0 7-1-0 1-0-0
Scale =1:69.7
7x10 M1118H-.
1
I
T1
,yyn B .
dA — —
SO WIN
7.00f12
N M O L
1.5.4 M1120 5,6 Mt120 - 6,8 160120 =
w3.
P
ss -
64 M1120o
wr. j ' w9
H
_—_ 4
CS
O K- J W W120=
602 Mt120 - 1 5A M1120
7-1-0
14-2-0
21-3-0
30-9-4
36-7-10
1
7-1-0
7-1-0
7-1-0
9-6-4
5-10-6
Plate Offsets (X,Y)_ [B:0-1-8,EdgeJ,_[C:0-4-0,0-3-0]. [D:0-4-0,0-3-0]. [F:0 3-4,Edge]. [G:0 5-0.0-3-4�[H_0-1,3,Edge, [L:0.4-0.0-3-4j. [M:0-3-0,0-3-0]_--
-- — -- - - -
LOADING (pso
SPACING 2-0-0
CSI
DEFL
in (loc) l/defl
Ud
PLATES
TCLL 35,0
Plates Increase 1.15
TC 0.67
Vert(LL)
-0.28 K-L >999
360
M1120
TCDL 7.0
Lumber Increase 1.15
BC 0.68
Vert(TL)
-0.45 K-L >808
240
M1118H
BCLL 0.0
Rep Stress tncr YES
WB 1.00
Horz(TL)
0.06 K nla
n/a
BCDL 7.0
Code IRC2006/TPI2002
(Matrix)
Wind(LL)
0.08 B-N >999
240
Weight: 189lb
LUMBER
BRACING
_ 42-&0
5-10-6
GRIP
197/144
141/138
TOP CHORD 2 X 4 SPF 1650F 1.5E TOP CHORD Structural wood sheathing directly applied or 3-9-9 oc purlins.
BOT CHORD 2 X 4 SPF 1650F 1.5E BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 2 X 4 SPF Stud/Std WEBS 1 Row at midpt C-M, D-L, F-K
REACTIONS (Ib/size) B=1580/0.5.8, K=276210-5-8, H=346/0-5-8
Max Horz B=393(LC 4)
Max UpliftB=-368(LC 5), K=-481(LC 6), H=-149(LC 6)
Max GravB=1580(LC 1), K=2762(LC 1), H=491(LC 10)
FORCES (lb) - Maximum Compression/Maximum Tension
TOP CHORD A-13=0145, B-C=-24161462, C-D=-1726/383, D-E=-985/327, E-F=-989/328, F-G=-81/768, G-H=-342/390, H-1=0145
BOT CHORD B-N=-442/1946, M-N=A42/1944, M-O=-224/1355, L-O=-224/1355, L-P=-37/196, P-Q=-37/196, K-0=-37/196, J-0-317/157, H-J=-306/176
WEBS C-N=01261, C-M=-682/283, D-M=-881537, D-L=-10081373, E-L=-112/325, F-L=-133/1011, F-K=-2177/448, G-0-611/290, G-J=0/191
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05: 90mph; h=25ft; TCDL=4.2psf; BCDL=4.2psf,, Category 11; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) All plates are MT20 plates unless otherwise indicated.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-" wide will fit between the bottom chord
and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 368 lb uplift at joint B. 481 lb uplift at joint K and 149 lb uplift at joint H.
7) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job - Truss - - Truss Type - - - - Oty Ply
B07142-08 J08 MONr 'SS 6 1
�— — — -- --- Jot1�,,.�nce (optional)_
BMC WEST (IDAHO FALLS), IDAHO FALLS. ID 83402 _ 7.03073an 3 2008 MTek Industries, Inc. Mon Jul 21 16:36:26 2008 Page 1
-1-0-0
1-0-0 4-0-0 4-0-0
o }}^
I
I
� I
f,S.e Mt120.
TW 12 ,v1
a c
w2
81
E
3A M1120- 3*4 M020 -
LOADING (psf)
TCLL 35.0
TCDL 7.0
BCLL 0.0
BCDL 7.0
SPACING 2-0-0
Plates Increase 1.15
Lumber Increase 1.15
Rep Stress Incr YES
Code IRC2006/TP12002
CSl
TC 0.24
BC 0.30
WB 0.17
(Matrix)
LUMBER
TOP CHORD 2 X 4 SPF 1650F 1.5E
BOT CHORD 2 X 4 SPF 240OF 2.0E
WEBS 2 X 4 SPF Stud/Std
REACTIONS (lb/size) E=364/Mechanical, B=492/0-5-8
Max Horz B=227(LC 5)
Max UpliftE=-146(LC 5), B=-108(LC 5)
FORCES (lb) - Maximum Compression/Maximum Tension
TOP CHORD A-B=0/45, B-C=-435/44, C-D=-101/51, D-E=-135176
BOT CHORD B-E=-178/307
WEBS C-E=-353/205
8-0-0
8-0-0
DEFL
Vert(LL)
Vert(TL)
Horz(TL)
Wind(LL)
in
(loc)
I/defl
Ud
-0.14
B-E
>645
360
-0.29
B-E
>315
240
0.00
E
n/a
n/a
PLATES GRIP
M1120 197/144
0.00 B "" 240 Weight: 31lb
scale- 1:25-5
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES
1) Wind: ASCE 7-05; 90mph; h=25ft; TCDL=4.2psf: BCDL=4.2psf; Category 11; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33.
2) This truss has been designed for a 10.0 psf bottom chord We load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 146 lb uptift at joint E and 108 lb uplift at joint B.
6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSIfTPI 1.
LOAD CASE(S) Standard
iJob i Truss Truss Type - - Oty -- Ply -- -- --
IB07142.08 J05 r' "0 TRUSS 4 -1 � -
l _ _ _ _ _ _ _ eference gpWna j�
AMC WEST (10AH0 FALLS), tDAHp FALLS, ID 83402 --- 0 s Jan 3 2008 Welt industries, Inc. Mon Jul 21 16:36:26 2008 Page 1
i -1-0-0 — ---- - 5-11-11-
1-0-0 5-11-11 c
�. sc.1e=,:1ea
/
7.00 i
a "
%'T1'
r
B
M
L
3m, M1120--
5-11-11
5-11-11
LOADING (psf) SPACING 2-0-0
CSI
DEFL in
(loc) Udell Ud
' PLATES GRIP
TCLL 35.0 Plates Increase 1.15
TC 0.51
Vert(LL) -0.06
B-D >999 360
M1120 1971144
TCDL 7.0 Lumber Increase 1.15
BC 0.24
Vert(TL) -0.12
B-D >570 240
BCLL 0.0 Rep Stress Incr YES
WB 0.00
Horz(TL) -0.00
C n/a n/a
BCDL 7.0 Code IRC20061TPI2002
(Matrix)
Wind(LL) 0.00
B "" 240
Weight: 16lb
LUMBER
BRACING
TOP CHORD 2 X 4 SPF 1650F 1.5E
TOP CHORD
Structural wood sheathing directly applied or 5-11-11 oc purlins.
BOT CHORD 2 X 4 SPF 1650F 1.5E
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size) C=219/Mechanical, B=394/0-5.8, D=40/Mechanical
Max Horz B=175(LC 5)
Max UpliftC=-126(LC 5), B=-99(LC 5)
Max GravC=219(LC 1), B=394(LC 1). D=97(LC 2)
FORCES (lb) - Maximum Compression/Maximum Tension
TOP CHORD A-13=0145, B-C=-128/90
BOT CHORD B-D=010
NOTES
1) Wind: ASCE 7-05; 90mph, h=25ft; TCDL=4.2psf; BCDL=4.2psf-, Category 11; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed , Lumber DOL=1.33 plate grip DOL=1.33.
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tail by 2-0-0 wide will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 126 lb uplift at joint C and 99 lb uplift at joint B.
6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSIITPI 1.
LOAD CASE(S) Standard
Job 'Truss Truss Type
B07142-08 J03 MONf 'SS
BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 _ -
_
1-0-0
f-- -
1-0-0
7.00 12
A
3*4 M1120 =
LOADING (psf)
SPACING
2-"
CSI
TCLL
35.0
Plates Increase
1.15
TC 0.17
TCDL
7.0
Lumber Increase
1.15
BC 0.10
BCLL
0.0
Rep Stress Ina
YES
WB 0.00
BCDL
7.0
Code IRC200&7PI2002
(Matrix)
LUMBER
TOP CHORD 2 X 4 SPF 165OF 1.5E
BOT CHORD 2 X 4 SPF 165OF 1.5E
REACTIONS (lb/size) C=127/Mechanical, B=303/0.5-8, D=261Mechanical
Max Horz B=127(LC 5)
Max UpliftC=-73(LC 5), B=-93(LC 5)
Max GravC=127(LC 1). B=303(LC 1), D=63(LC 2)
FORCES (lb) - Maximum Compression/Maximum Tension
TOP CHORD A-B=0/45, B-C=90/52
BOT CHORD B-D=010
TI
Oty �Ply — - - -.
4 1
-- Jo nee (oplional)
7.03 an 3 2008 MTek Industries, Inc. Mon Jul 21 16:36:25 2008 Page 1
- — 3-11-11 -- - - - - -1
3-11-11 c
Scde = 1:13 0
k
x
BI
3-11-11
DEFL in (loc) Vdefl Ud PLATES GRIP
Vert(LL) -0.01 B-D >999 360 MI120 197/144
Vert(TL) -0.02 B-D >999 240
Horz(TL) -0.00 C nla n/a
Wind(LL) 0.00 B 240 Weight: 11lb
BRACING
TOP CHORD Structural wood sheathing directly applied or 3-11-11 oc pudins.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES
1) Wind: ASCE 7-05: 90mph; h=25ft; TCDL=4.2psf; BCDL=4.2psf; Category It: Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed : Lumber DOL=1.33 plate grip DOL=1.33.
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 73 lb uplift at joint C and 93 lb uplift at joint B.
6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TP11.
LOAD CASE(S) Standard
Job — — Truss -- Truss Type - - - Oty Ply
B07142-08 J01 r '7 TRUSS 4 1
f - - - -- - - --- - - - - -- - - - - -- deference (optional)
BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 0 s Jan 3 200B MiTek Industries, Inc. Mon Jul 21 16:36:24 2008 Page 1
Stake 183
3r1 W120 -
1-11-11
LOADING (psi)
SPACING
2-0-0
CSI
DEFL in (loc) Udell Ud
PLATES GRIP
TCLL 35.0 f
Plates Increase
1.15
TC 0.10 i
Vert(LL) -0.00
B >999 360
M1120 197/144
TCDL 7.0
f
Lumber Increase
1.15
BC 0.03
Vert(TL) -0.00
B-D >999 240
BCLL 0.0
I
Rep Stress lncr
YES
WB 0.00
Horz(TL) -0.00
C n/a n/a
BCDL 7.0
I
Code IRC2WWPI2002
(Matrix)
Wind(LL) 0.00
B "" 240
Weight: 6 lb
LUMBER
BRACING
TOP CHORD 2 X 4 SPF 165OF 1.5E
TOP CHORD
Structural wood sheathing directly applied or 1-11-11 oc pudins.
BOT CHORD 2 X 4 SPF 165OF 1.5E
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size) B=214/0-5.8, D=13/Mechanical, C=51/Mechanical
Max Horz B=83(LC 5)
Max UpliftB=-86(LC 5), C=-25(LC 5)
Max Grav B=214(LC 1), D=33(LC 2), C=51(LC 1)
FORCES (Ib) - Maximum Compression/Maximum Tension
TOP CHORD A-B=0/43, B-C=-56/19
BOT CHORD B-D=0/0
NOTES
1) Wind: ASCE 7-05; 90mph; h=25ft; TCDL=4.2psf; BCDL=4.2psf; Category II; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33.
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 86 lb uplift at joint B and 25 Ib uplift at joint C.
6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job Truss Truss Type Oty I Ply
B07142-08 H02 HIP 1 1
- - Jotl,._�nce_ (op!iqnall_
SIVIC WEST -IDAHO FALLS, ID 83402 7.030T-Jan 3 2008MiTek Industries, Inc. Mon Jul 2116:36:242008 Pagel
.1-0-0 6-0-0 12-" 14-0-0 20-0-0 26-0-0 27-0-0
1-0-0 6-0-0 "_0 2-" 6-0-0 6-0-0 1-"
ScsW - 1:44.4
A
5x6 NO
E
L K 1 1
1.5A M1120 SX5 &0120 — 3A Lt1t20= I 51A M1120 11
5,9 K9120
6-0-0 12-0-0 14-M 20-0-0 26-0-0
6-0-0 6-0-0 2-" 6-" 6-0-0
Plate iOffsetsX, -�R.q4-�3.Ed ej, (K-.0-3-0,0-3-0]
_[Q.b:4 1 -11 , [E:0-3-4.0-241, LG:O-1 -33,E
LOADING (psf) SPACING 2-0-0 CS1 DEFL in (Ioc) Vdefl Ud PLATES GRIP
TCLL 35.0 Plates Increase 1.15 TC 0.44 Vert(LL) -0.09 K >999 360 M1120 197/144
TCDL 7.0 Lumber Increase 1.15 BC 0.39 Vert(TL) -0.17 K-L >999 240
BCLL 0.0 Rep Stress Incr YES WB 0.62 Horz(TL) 0.07 G n1a n1a
BCDL 7.0 Code IRC2006/TPI2002 (Matrix) Wind(LL) 0.05 K >999 240 Weight: 113 lb
J
LUMBER BRACING
TOP CHORD 2 X 4 SPF 165OF 11.512 TOP CHORD Structural wood sheathing directly applied or 4-7-2 oc purlins.
BOT CHORD 2 X 4 SPF 1650F 11.5E BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2 X 4 SPF Stud/Std
REACTIONS (Ib/size) B=136110-5-8, G=1361/0-5-8
Max Horz B=224(LC 4)
Max Up1lftB=-324(LC: 5), G=-324(LC 6)
FORCES (1115) - Maximum Compression/Maximum Tension
TOP CHORD A-B=0/45,B-C=-2048/392.C-D=-14521328,D-E=-1146/338,E-F=-14551329.F-G=-2046/393,G-H=0/45
BOT CHORD B-L=-330/1647.K-L=-330/1647.J-K=-121/1144,1-J=-222/1646,G-1=-22211646
WEBS C-L=0/225, C-K=-598/243. D-K=-86/338, D-J=2631279, E-J=-102/401, F-J=-595/243, F-1=0/223
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05, 90mph; h=25ft; TCDL=4.2psf; BCDL=4.2psf; Category 11; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed Lumber DOL=11.33 plate grip DOL=1.33.
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord
and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 324 lb uplift at joint B and 324 lb uplift at joint G.
7) This truss is designed in accordance with the 2006 International Residential Code sections R502.1 1.1 and R802.10.2 and referenced standard ANSIfTPI 1.
LOAD CASE(S) Standard
Job
Truss
Truss Type
oty Ply
! B07142-08
H01
f'
1
FALLS), IOAHO FALLS,10
,Ieference optional)
Jul
BMCWEST (IDAHO
83402
s Jan 3 2008 MTek Industries, Inc.
Mon 21 16:36:23 2008 Page 1
-1-0_0 -
5-0-0
10-0-0
16-0-0
21-0-0
26-0-0 7-0-
1-0-0
5-0-0
5-0-0
414 M1120
6-0-0
5-0-0
5-0-0 1-0-0
srde= V44.4
.
D
1000 M1120,
E
700, i2 I 5A MI20'
� � I.5w4 M1120,
w2
w,,'
\�
,e
C
\ p
,n
eV
71
94
w3
w3,
516M I20
J
M M1120=
514 M320—
54 M1120
10-0-0 26-0-0
10-0-0 6-0-0 10-0-0
Aaie_offsets (X,y)_[B:0-1-Tgdgel,_PQ+8.0-2-01 Lo-64,a�, [c:0-1-7,Ed9el. I�-o;a3-off__
LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) Vdefl Ud PLATES GRIP
TCLL 35.0 Plates Increase 1.15 TC 0.39 Vert(LL) -0.23 G-1 >999 360 ! M1120 197/144
TCDL 7.0 Lumber Increase 1.15 BC 0.45 j Vert(TL) -0.50 G-1 >617 240
BCLL 0.0 Rep Stress Ina YES I WB 0.28 Horz(TL) 0.07 G n/a n/a
BCDL 7.0 j Code IRC20061TP12002 1 (Matrix) Wind(LL) 0.04 B-J >999 240 Weight: 101 lb
LUMBER BRACING
TOP CHORD 2 X 4 SPF 1650F 1.5E TOP CHORD Structural wood sheathing directly applied or 4-8-11 oc pudins.
BOT CHORD 2 X 4 SPF 1650F 1.5E BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2 X 4 SPF Stud/Std
REACTIONS (lb/size) B=1361/0-5-8, G=1361/0-5-8
Max Horz B=187(LC 4)
Max UpliftB=-314(LC 5), G=-314(LC 6)
FORCES (lb) - Maximum Compression/Maximum Tension
TOP CHORD A-B=0/45, B-C=-2004/409, C-D=-1630/320, D-E=-1325/329, E-F=-1630/320, F-G=-2004/409, G-H=0/45
BOT CHORD B-J=-337/1646, I-J=-127/1324, G-1=-243/1646
WEBS C-J=-377/219, D-J=-35/317, E-J=-205/206, E-1=40/317, F-1�377/219
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; h=25ft; TCDL=4.2psf; BCDL=4.2psf, Category II; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33.
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live toad nonconcun-ent with any other live toads.
5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will lit between the bottom chord
and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 314 lb uplift at joint B and 314 lb uplift at joint G.
7) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSIfrPI 1.
LOAD CASE(S) Standard
Jab Truss Truss Type
B07142-08 GE02 i GAB[/
BMC WEST (IDAHO FALLS), IDAHO FALLS, ID $3402 T
Qty Ply
1 1 '
Jo ence (optional)-
7.030rJan 3 2008 MTek Industries, Inc. Mon Jul 21 16:36:22 2008 Page 1
-1_ 0-0
1-0-0
B
n
it
A
-4-6-0 —
4-6-0
4A M1120 =
D
9-0-0 10-0-0
4-6-0 1-0-0
scale 2 1:17.6
3A A1020� 1,5"1 A91201I 1.$A U11201! 1.5a4 A01201t 3A A0120=
w n n
1= IF
LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) !ldefl Ud PLATES GRIP
TCLL 35.0 Plates Increase 1.15 TC 0.11 Vert(LL) -0.00 G n/r 120 M1120 197/144
TCDL 7.0 Lumber Increase 1.15 BC 0.04 Vert(TL) -0.00 G n/r 120
BCLL 0.0 Rep Stress Ina NO WB 0.06 Horz(TL) 0.00 F Na n/a
BCDL 7.0 Code IRC2006/TPI2002 (Matrix) Weight: 31 lb
LUMBER BRACING
TOP CHORD 2 X 4 SPF 165OF 1.5E TOP CHORD Structural wood sheathing directly applied or 6.0-0 oc puriins.
BOT CHORD 2 X 4 SPF 165OF 1.5E BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2 X 4 SPF Stud/Std
REACTIONS (lb/size) 8=22219-0-0, F=222/9-0-0,1=130/9-0-0, J=244/9-0-0. H=244/9-0-0
Max Horz 6=-86(LC 3)
Max UpliftB=-83(LC 5). F=-94(LC 6). J=-87(LC 5). H=-87(LC 6)
FORCES (lb) - Maximum Compression/Maximum Tension
TOP CHORD A-B=0/43, B-C=-74/61, C-D=-71179, D-E=-71/71, E-F=-74/42, F-G=0143
BOT CHORD B-J=-10/66,1-J=-10/66. H-I=-10/66, F-H=-10/66
WEBS D-1=-108/2, C-J=-206/110, E-H=-206/110
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph. h=25ft; TCDL=4.2psf; BCDL=4.2psf: Category 11; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33.
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see MTek "Standard Gable End Detail"
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Gable requires continuous bottom chord bearing.
6) Gable studs spaced at 2-0-0 oc.
7) " This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord
and any other members.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 83 lb uplift at joint B. 94 lb uplift at joint F, 87 Ib uplift at joint J and 87 lb
uplift at joint H.
9) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job • I Truss Truss Type
B07142-08 JGE01A r '' E
--'i�-
BMC WEST (IDAFiO FALLS), IDAHO FALLS, ID 83402
4-0-0 21-3-0
1-0-0 21-3-0
I
i
IN I
- Qi ply
Y -
1 1
�2eference (optional)
0 s Jan 3 218 MTek Industries, Inc. Mon Jul 21 16:36:21 2008 Page 1
42-6-0
21-M
Scale * I M a
54 M1120 =
M
3PG M1120= 3.6 M1120-
42-6-0
42-6-0
id
Plate Offsets (X,Y)[B:0-34,0-1-8],[F:0-1-13,0.1-8],[f:0-1-13,0-1-8],[X:0-34,0-1-8]
LOADING (psf) SPACING 2-0-0 I CSI DEFL in (loc) tldefl Ud PLATES GRIP
TCLL 35.0 Plates Increase 1.15 I TC 0.14 Vert(LL) -0.00 A n/r 120 M1120 197/144
TCDL 7.0 Lumber Increase 1.15 BC 0.09 Vert(TL) 0.00 A n/r 120
BCLL 0.0 Rep Stress Ina NO WB 0.21 Horz(TL) 0.01 X n/a n/a
BCDL 7.0 Code IRC2006/TPI2002 (Matrix) Weight: 251 lb
LUMBER BRACING
TOP CHORD 2 X 4 SPF 165OF 1.5E TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc pudins.
BOT CHORD 2 X 4 SPF 165OF 1.5E BOT CHORD Rigid ceiling directly applied or 10-M oc bracing.
OTHERS 2 X 4 SPF Stud/Std WEBS 1 Row at midpt M-AI, L-AJ, K-AK, J-AM, N-AH, O-AG, P-AE
REACTIONS (lb/size) B=254/42-6-0, AI=171/42-6-0, AJ=194/42-6-0, AK=197/42-6-0, AM=196/42-", AN=196/42-6-0, AO=196/42-6-0. AP=194/42-6-0, AQ=205/42-6-0, AR=160/42-6-0, AS=295/42-",
AH=194/42-6-0, AG=197/42-6-0, AE=196142-6-0, AD=196142-6-0, AC=197/42-6-0, AB=193142-", AA=208/42-6-0, Z=148/42-6-0, Y=325142-6-Q X=144/42-6-0
Max Horz B=402(LC 4)
Max UpliftB=-103(LC 3), AJ=53(LC 5), AK=-87(LC 5), AM=-77(LC 5), AN=-78(LC 5), AO=-78(LC 5), AP=-78(LC 5), AQ=-80(LC 5), AR=-69(LC 5), AS=-110(LC 5), AH=47(LC 6), AG=-89(LC 6),
AE=-77(LC 6), AD=-78(LC 6), AC=-78(LC 6), AB=-77(LC 6). AA=-83(LC 6), Z=-59(LC 6), Y=-133(LC 6), X=-14(LC 4)
Max GrayB=254(LC 1). A1=242(LC 6). AJ=201(LC 9). AK=197(LC 1), AM=196(LC 1), AN=196(LC 9), AO=196(LC 1), AP=194(LC 9), AQ=205(LC 1), AR=160(LC 9), AS=295(LC 9), AH=201(LC 10).
AG=197(LC 1), AE=196(LC 1), AD=196(LC 10), AC=197(LC 1), AB=193(LC 10), AA=208(LC 1), Z=148(LC 10), Y=325(LC 10), X=144(LC 1)
FORCES (lb) - Maximum Compression/Maximum Tension
TOP CHORD A-B=0/43, B-C=-347/239, C-D=-290/225, D-E=-256/223, E-F=-217/210, F-G=-2131217, G-H=-180/213, H-1=-142/208, I-J=-105/213, J-K=-70/252,
K-L=-70/295, L-M=-69/319, M-N=-69/311, N-0=-70/270, O-P=-70/209, P-Q=-70/153, Q-R=-70/113, R-S=-70/74, S-T=-62166, T-U=-70/59,
U-V=-105/72, V-W=-138/74, W-X=-216187
BOT CHORD B-AS=-71/219, AR-AS=-71/219, AO-AR=-71/219, AP-AQ=-71/219, AO-AP=-71/219, AN-A0=-71/219, AM-AN=-71/219, AL-AM=-71/219,
AK-AL=-71/219, AJ-AK=-71/219, AI-AJ=-71/219, AH-AI=-71/219, AG-AH=-71/219, AF-AG=-711219, AE-AF=-71/219, AD-AE=71/219,
AC-AD=-71/219, AB-AC=-71/219, AA-AB=-71/219, Z-AA=-71/219, Y-Z=-71/219, X-Y=-711219
WEBS M-AI=-22610, L-AJ=173/70, K-AK=-169/104, J-AM=-168/94, I-AN=-168/95, H-AO=168195, G-AP=-167/94, E-AQ=-174/97, D-AR=-143/84,
C-AS=-2401132, N-AHr173164, O-AG�1691106, P-AE=-168/93, Q-AD=-168/95, R-AC=-168/95, S-AB=-167/94, U-AA=-175/98, V-Z=-138/79,
W-Y=-254/142
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; h=25ft; TCDL=4.2psf: BCDL=4.2psf; Category II; Exp C; enclosed, MWFRS (law -rise) gable end zone; cantilever left and right exposed ;
Lumber DOL=1.33 plate grip DOL=1.33.
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face). see MTek "Standard Gable End Detail"
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) All plates are 1.5x4 M1120 unless otherwise indicated.
6) Gable requires continuous bottom chord bearing.
7) Gable studs spaced at 2-0-0 oc.
8) ' This truss has been designed for a live load of 20.Qpsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord
and any other members.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 103 lb uplift at joint B, 53 lb uplift at joint AJ, 87 lb uplift at joint AK, 77 lb
uplift at joint AM, 78 lb uplift at joint AN, 78 lb uplift at joint AO, 78 lb uplift at joint AP, 80 lb uplift at joint AQ, 69 lb uplift at joint AR, 110 lb uplift at joint AS, 47 lb
uplift at joint AH, 89 lb uplift at joint AG, 77 ►b uplift at joint AE, 78 lb uplift at joint AD, 78 lb uplift at joint AC, 77 lb uplift at joint AB, 83 lb uplift at joint AA, 59 lb uplift
at joint Z,133 lb uplift at joint Y and 14 lb uplift at joint X.
10) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI1TPI 1.
LOAD CASE(S) Standard
iJob - -- - - Truss - Truss Type Qty ' Ply
B07142-08 GE01 i GABI 1 I 1 -
i-
BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 7.03LTJan 3 2008 MiTek Industries, Inc. Mon .Jul 21 16:36:19 2008 Page 1
-i1-0-0 21-3-0 42-&0 43-"
1-0-0 21-3-0 21-3-0 1-M
Scab - 1:69.9
SQL M020-
M
L 11 N
7 001 12 K `. O
TZ
I \\
\\
r
0 � \
H ST9
N 34L0120� STB }
�:
/ ! S 3�6Aa120.•
I
i %���� v
r sT. 1 su
i
Cw
TT . SIIT2 I V j STZ -�.\�+
T
iF - -- 1 + I1�i I- - -i} �} } - {};` st ItF 11,x Y iN
3a8 M1120 = AT AS AR AO AP AO AN MI AL AK AJ Al AH AG AF AE AD AC AB AA Z 3j6M1120=
34 M1120 34 M1120 -
42-6-0
A*?A.n
-PEa- -
- _te o_ftsets�X,�-I_--
LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/deft Ud PLATES GRIP
TCLL 35.0 Plates Increase 1.15 TC 0.13 Vert(LL) 0.00 X n/r 120 M1120 197/144
TCDL 7.0 Lumber Increase 1.15 BC 0.06 Vert(TL) 0.00 Y nlr 120
BCLL 0.0 Rep Stress Ina NO WB 0.21 Horz(TL) 0.02 X We n/a
BCDL 7.0 ' Code IRC2006/TPI2002 (Matrix) Weight: 252 lb
LUMBER BRACING
TOP CHORD 2 X 4 SPF 165OF 1.5E TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2 X 4 SPF 165OF 1.5E BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2 X 4 SPF Stud/Std WEBS 1 Row at midpt M-AJ, L-AK, K-AL, J-AN, N-AI, O-AH, P-AF
REACTIONS (lb/size) B=254/42-". AJ=171/42-6.0, AK=194/42-6-0, AL=197/42-6-0, AN=196/42-6-0, AO=196/42-", AP=196/42-6-0, AQ=194142-6-0, AR=205/42-6-0, AS=160142-6-0, AT=295142.E-0,
A1=194/42-6-0, AH=197/42-6-0, AF=196/42-6-0, AE=196/42-6-0, AD=196/42-64 AC=194/42-6-0, AB=205142-6-0, AA=160/42-6-0, Z=295/42-6-0, X=254/42-6-0
Max Horz B=393(LC 3)
Max UpliftB=-105(LC 3). AK=-53(LC 5). AL=-87(LC 5), AN=-77(LC 5), AO=-78(LC 5). AP=-78(LC 5), AQ=-78(LC 5). AR=-80(LC 5), AS=-69(LC 5), AT=-11O(LC 5), AI=-46(LC 6). AH=-89(LC 6).
AF=-77(LC 6), AE=-78(LC 6), AD=-78(LC 6), AC=-78(LC 6), AB=-80(LC 6), AA=.69(LC 6), Z=-109(LC 6), X=-27(LC 4)
Max Grav B=254(LC 1), AJ=254(LC 6). AK=201(LC 9), AL=197(LC 1). AN=196(LC 1), AO=196(LC 9), AP=196(LC 1), AQ=194(LC 9), AR=205(LC 1). AS=160(LC 9), AT=295(LC 9), AI=201(LC 10).
AH=197(LC 1), AF=196(LC 1), AE=196(LC 10), AD=196(LC 1). AC=194(LC 10), AB=205(LC 1), AA=160(LC 10), Z=295(LC 10), X=254(LC 1)
FORCES (lb) - Maximum Compression/Maximum Tension
TOP CHORD A-B=0/43, B-C=343/244, C-D=-286/229, D-E=-252/228, E-F=-214/214, F-G=-210/222, G-H=-176/217, H-1=-139/213, I-J=-101/226, J-K=-701265,
K-L=-70/309, L-M=-69/331, M-N=-69/324, N-O=-70/283, O-P=-70/222, P-Q=-70/167, Q-R=-70/118, R-S=-70/79, S-T=-57/70, T-1.11=-70/62,
U-V=-100175, V-W=-134177, W-X=-199/91, X-Y=0143
BOT CHORD B-AT=-64/242, AS-AT=-64/242, AR-AS=-641242, AQ-AR=-64/242, AP-AQ=-64/242, AO-AP=-64/242, AN-AO=-64/242, AM-AN=-64/242,
AL-AM=-64/242, AK-AL=-64/242, AJ-AK=-64/242, AI-AJ=-64/242, AH-AI=-641242, AG-AH=-64/242, AF-AG=-64/242, AE-AF=-64/242,
AD-AE=-64/242, AC-AD=64/242, AB-AC=-64/242, AA-AB=-64/242. Z-AA=-64/242, X-Z=-64/242
WEBS M-AJ=23710, L-AK=-173/69, K-AL=-169/104, J-AN=168194, I-AO=-168/95, H-AP=-168/95, G-AQ=-167/94, E-AR=-174/97, D-AS=-143184,
GAT=-240/132, N-AI=-173/63, O-AH=-169/106. P-AF=-168193, Q-AE=-168/95, R-AD=-168/95, S-AC=-167/94, U-AB=-174/97, V-AA=-143/84,
W-Z=240/131
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph, h=25ft; TCDL=4.2pst BCDL=4.2psf; Category II; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ;
Lumber DOL=1.33 plate grip DOL=1.33.
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see MiTek "Standard Gable End Detail"
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) All plates are 1.5x4 M1120 unless otherwise indicated.
6) Gable requires continuous bottom chord bearing.
7) Gable studs spaced at 2-0-0 oc.
8) " This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord
and any other members.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 105 lb uplift at joint B, 53 lb uplift at joint AK, 87 lb uplift at joint AL, 77 lb
uplift at joint AN, 78 lb uplift at joint AO, 78 lb uplift at joint AP, 78 lb uplift at joint AQ, 80 lb uplift at joint AR, 69 lb uplift at joint AS, 110 lb uplift at joint AT, 46 lb uplift
at joint Al, 89 lb uplift at joint AH, 77 lb uplift at joint AF, 78 lb uplift at joint AE, 78 lb uplift at joint AD, 78 lb uplift at joint AC, 80 lb uplift at joint AB, 69 lb uplift at joint
AA, 109 lb uplift at joint Z and 27 lb uplift at joint X.
10) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job b. Truss TrussT--
f
B07142-08 CJ11 r' O TRUSS
BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 "%�
-1-5-0 } - -- --- -- 5-7-14 - --
1-5-0 5-7-14
-�O Ply ! - -- —
2 1
2eference (optional)
s Jan 3 2008 MiTek Industries, Inc. Mon Jul 21 16:36:17 2008 Page 1
11-3-12
5-7-14
44 M1120 11
1i
D
H
3,4 L11120 =
a.nli2 -" � � � I wt ,
c _
a wa w2
�B _ _ I F J E
= =- SM M1120 1,
4.4 M1120 - - SA M1120=
Plate Offsets (X,Y): (D:0-34,Edge]_ - _-
LOADING (psf)
SPACING
2-0-0
TCLL
35.0
Plates Increase
1.15
TCDL
7.0
Lumber Increase
1.15
BCLL
0.0
Rep Stress Ina
NO
BCDL
7.0
Code IRC2006/TPI2002
LUMBER
TOP CHORD 2 X 4 SPF 165OF 1.5E
BOT CHORD 2 X 6 DF 1800F 1.6E
WEBS 2 X 4 SPF Stud/Std *Except*
W1 2 X 4 SPF 165OF 1.5E
REACTIONS (lb/size) E=772/Mechanical, B=77110-7-12
Max Horz B=228(LC 5)
Max UpliftE=-341(LC 5). B=-266(LC 5)
5-7-14 - } - 11-3-12 —1
5-7-14 5-7-14
CSI
DEFL
in (loc)
Udefl
TC 0.64
Vert(LL)
-0.02 F
>999
BC 0.19
Vert(TL)
-0.05 E-F
>999
WB 0.70
Horz(TL)
0.01 E
n/a
(Matrix) !
Wind(LL)
0.02 F
>999
BRACING
FORCES (lb) - Maximum Compression/Maximum Tension
TOP CHORD A-B=0/52, B-G=-1109/317, C-G=-974/317, C-H=-231/67, D-H=-49/36, D-E=-312/183
BOT CHORD B-1=420/965, F-I=-420/965, F-J=-420/965, E-J=420/965
WEBS C-F=0/329, C-E=-947/400
Ud
PLATES
360
M1120
240
n/a
240
i Weight: 53lb
GRIP
197/144
Scee- 1Z4.6
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc pudins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES
1) Wind: ASCE 7-05; 90mph; h=25ft; TCDL=4.2psf; BCDL=4.2psf; Category 11; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33.
2) This truss has been designed for a 10.0 psf bottom chord live load noneoncurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3.6-0 tall by 24U-0 wide will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 341 lb uplift at joint E and 266 lb uplift at joint B.
6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 9 lb down and 29 lb up at 2-104, 9 lb dawn and 29 lb up at
2-104, 38 lb down and 63 lb up at 5-8-3, 38 lb down and 63 lb up at 5-8-3. and 119 lb down and 116 lb up at 8-6-2, and 119 lb down and 116 lb up at 8-6-2 on
top chord, and 1 lb up at 2-104.1 lb up at 2-104, 29 lb down at 5-8-3, 29 lb down at 5-8-3, and 63 lb down at 8-6-2, and 63 lb down at 8-6-2 on bottom chord.
The design/selection of such connection device(s) is the responsibility of others.
8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Regular: Lumber Increase=1.15. Plate Increase=1.15
Uniform Loads (plf)
Vert: A-D=-84, B-E= 14
Concentrated Loads (lb)
Vert: C=-76(F=-38, B=-38) F=-24(F=-12, B=-12) G=58(F=29, B=29) H=-237(F=-119, B=-119)1=1(F=1, B=1) J=-52(F=-26, B=-26)
Job !Truss Truss Type - - QtyMY-
-- �-
{ j- - -
B07142-08 GR01 HIP 1
1 2 I Jok�Jence (optional)
BNIC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 7.03OWan 3 2008 M17ek Industries, Inc. Mon Jul 21 16:36:16 2008 Page 1
1-0-0, 4-0-0 8-0-0 13-0-0 18-0-0 - 22-0-0 26-0-0 27-0-
1-0-0 4-0-0 4-0-0 5-0-0 5-0-0 4-0-0 4-0-0 1-0-0
Scab = 1:44.4
6■S W 120
0
6� Mi120:
1.5"4 0120 +I
E F
�. wzN w2 W1'
W3
i
N M O P L O R K
3"4 M11201 1 4"4 M1120 - 74 L4120 - 41,4 M1120
34 M1120,
G
� � N
3"4 M020 Sib M1120
4-0-0 8-0-0 13-0-0 18-0-0 22-0-0 26-0-0
4-0-0 4-0-0 5-0-0 5-0-0 4-0-0 4-0-0
Plate Offsets(X,Y}__[6:0-3-15,0-2.8],[D_:0_-4-0,0-1-11 F[ •0-4-0,0-1-11 ,[H:0-3-15,0-2-8],_[L:0-4-0,0-4-8]
---- - - - - - - — -----
- — ----
LOADING (psQ
SPACING 2-0-0
CSI
DEFL
in
(loc)
lldefl
Ud PLATES
TCLL 35.0
Plates Increase 1.15
TC 0.20
Vert(LL)
-0.12
K-L
>999
360 MI120
TCDL 7.0
Lumber Increase 1.15
! BC 0.30
Vert(TL)
-0.20
K-L
>999
240
BCLL 0.0
Rep Stress Incr NO
WB 0.43
Horz(TL)
0.06
H
n/a
n/a
BCDL 7.0
Code iRC200&TP12002
(Matrix) I
Wind(LL)
0.10
L-M
>999
240 Weight: 268lb
GRIP
197/144
LUMBER BRACING
TOP CHORD 2 X 4 SPF 165OF 1.5E TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purfins.
BOT CHORD 2 X 6 DF 180OF 1.6E BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2 X 4 SPF Stud/Std
REACTIONS (lb/size) B=3006/0-5-8, H=3006/0-5-8
Max Horz B=-149(LC 3)
Max UpiiftB=-1114(LC 5), H�l114(LC 6)
FORCES (lb) - Maximum Compression/Maximum Tension
TOP CHORD A-B=0/50, B-C=-5170/1873, C-D=-501111941, D-E=499811978, E-F=4998/1978, F-G=-5011/1941, G-H=-5170/1874, H-1=0/50
BOT CHORD B-N=-1680/4342, M-N=-1680/4342, M-0=-1730/4308, O-P=-1730/4308, L-P=-1730/4308, L-Q=-1617/4308, Q-R=-161714308, K-R=-1617/4308, J-K=-1533/4342, H-J=-153314342
WEBS C-N=-1001102, C-M=-2151174, D-M=-028/1437, D-L=49911079, E-L=406/206, F-L=49911079, F-K=-628/1437, G-K=-217/174, G-J=-100/101
NOTES
1) 2-ply truss to be connected together with 10d (0.131"x3") nails as follows:
Top chords connected as follows: 2 X 4 -1 now at 0-9-0 oc.
Bottom chords connected as follows: 2 X 6 - 2 rows at 0-7-0 oc.
Webs connected as follows: 2 X 4 -1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been
provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Unbalanced roof live loads have been considered for this design.
4) Wind: ASCE 7-05; 90mph; h=25ft; TCDL=4.2psf; BCDL=4.2psf; Category 11; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ;
Lumber DOL=1.33 plate grip DOL=1.33.
5) Provide adequate drainage to prevent water ponding.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
7)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord
and any other members.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1114 lb uplift at joint B and 1114 lb uplift at joint H.
9) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
10) Use USP HJC26 nth 16d nails into Girder & 10d nails into Truss) or equivalent spaced at 9-11-4 oc max. starting at B-0-6 from the left end to 17-11-10 to
connect truss(es) J08 (1 ply 2 X 4 SPF), CJ11 (1 ply 2 X 6 DF), J08 (1 ply 2 X 4 SPF), CJ11(1 ply 2 X 6 DF) to front face of bottom chord.
11) Use Simpson Strong -Tie LUS24 (4-10d Girder, 2-10d Truss, Single Ply Girder) or equivalent spaced at 2-0-0 oc max. starting at 10-0-12 from the left end to
15-11-4 to connect truss(es) J08 (1 ply 2 X 4 SPF) to front face of bottom chord.
12) Fill all nail holes where hanger is in contact with lumber.
LOAD CASE(S) Standard
1) Regular: Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: A-D=-84, D-F=-84, F-I=-84, B-H=-14
Concentrated Loads (lb)
Vert: M=-1019(F) K=-1019(F) 0=-313(F) P=-313(F) Q=-313(F) R=-313(F)
c
GEOI A
N
0 N N
W 0 0
0 � �
MG -WEST -TRUSS -PLANT
715 Bombardier Name: Truss transferred from Layout
aho 1`alls, Id Address: Job: _ T
3402 -
N M
r
^
0 0
0
^
0�
.J O '1
.J 0 3
1.�
JO5
i
J05
r
JO3
N r
0 0
0
N
(�
r .j o l
0
0
0�
�,
Qty Ply
-------- ------
Truss Type
,lob ___JTruss
B07142-08
GR01
HIP
1
�f
2
Job Reference (optional)____
BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
7.030 s Jan 3 2008 MiTek Industries, Inc. Mon Jul 21 16:36:16 2008 Page 1
8-0-0 13-0-0 18-0-0 22-0-0
1-0-0 4-0-0 4-0-0 5-0-0 5-0-0 4-0-0
SIB M1120 S-
O
7.00112 3,6 Mg20
bN c
_ "W I W3
vA /a�-- --- — -- — -
:W2
I.SM MI120 1
E
I
W2,, pil
US M1120:
r
N M O P L O R K
54 M020 3A M1120 4"1 16Cp20= 7.8 L9120 = 4"4 M1120
4-0-0 8-0-0 13-0-0 18-0-0 1 22-0-0
'r- - - -- -- --- -} - - -- . T - --
4-0-0 4-0-0 5-0-0 5-0-0 4-0-0
Plate OHseis (X,Y) [ .973-15,0-22 1._jo:0-4-OP-1-111 [F:0-4-0,0-1-11),[H:0-3-15,0-2-8)._[L_011-O.o-4-8] - — - - -- - --
LOADING (psQ SPACING 2-0-0 CSI DEFLin (loc) l/defl Ud
TCLL 35.0 Plates Increase 1.15 TC 0.20 Vert(LL) -0.12 K-L >999 360
TCDL 7.0 Lumber Increase 1.15 BC 0.30 Vert(TL) -0.20 K-L >999 240
BCLL 0.0 Rep Stress Incr NO WB 0.43 Horz(TL) 0.06 H n/a nla
BCDL 7.0 Code tRC2006/TPI2002 (Matrix) Wind(LL) 0.10 L-M >999 240
LUMBER BRACING
26-0-0 27-Q
----- -r-
_
4-0-0 1-0-0
scse --1A4.4
3A W1201 � 5A M1120
26-0-0
4-0-0
PLATES GRIP
M1120 197/144
Weight: 268 lb
TOP CHORD 2 X 4 SPF 165OF 1.5E TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2 X 6 DF 180OF 1.6E BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2 X 4 SPF Stud/Std
REACTIONS (lb/size) B=300610-5-8, 11-1=300610-5-8
Max Hors B=-149(LC 3)
Max Up1iftB=-1114(LC 5). H=-1114(LC 6)
FORCES (lb) - Maximum Compression/Maximum Tension
TOP CHORD A-B=0150, B-C=-5170/1873, C-D=-5011/1941, D-E=-4998/1978, E-F=-4998/1978, F-G=-501111941, G-H=-517011874, H-1=0/50
BOT CHORD B-N=-168014342, M-N=-168014342, M-0=-173014308, O-P=-1730/4308, L-P=-173014308, L-Q=-161714308, Q-R=-1617/4308, K-R=-161714308, J-K=-1533/4342, H-J=-1533/4342
WEBS C-N=-100/102, C-M=-215/174, D-M=-628/1437, D-L=-499/1079, E-L=406/206, F-L=49911079, F-K=-628/1437, G-K=-217/174, G-J=-100/101
NOTES
1) 2-ply truss to be connected together with 14d (0.131"x3") nails as follows:
Top chords connected as follows: 2 X 4 -1 row at 0-9-0 oc.
Bottom chords connected as follows: 2 X 6 - 2 rows at 0-7-0 oc.
Webs connected as follows: 2 X 4 -1 row at 0-9-0 oc.
2) All loads are considered equally applied to all plies, except if noted as front (F) or back (B) face in the LOAD CASE(S) section. Ply to ply connections have been
provided to distribute only loads noted as (F) or (B), unless otherwise indicated.
3) Unbalanced roof live loads have been considered for this design.
4) Wind: ASCE 7-05; 90mph; h=25ft; TCDL=4.2psf; BCDL=4.2psf; Category 11. Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ;
Lumber DOL=1.33 plate grip DOL=1.33.
5) Provide adequate drainage to prevent water ponding.
6) This truss has been designed for a 10.0 psf bottom chord live load nonconcun-ent with any other live loads.
7) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-&0 tall by 2-0-0 wide will fit between the bottom chord
and any other members.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 1114 lb uplift at joint B and 1114 lb uplift at joint H.
9) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
10) Use USP HJC26 (With 16d nails into Girder 81Od nails into Truss) or equivalent spaced at 9-114 oc max. starting at 8-0-6 from the left end to 17-11-10 to
conned truss(es) J08 (1 ply 2 X 4 SPF), CJ11 (1 ply 2 X 6 DF), J08 (1 ply 2 X 4 SPF), CJ11 (1 ply 2 X 6 DF) to front face of bottom chord.
11) Use Simpson Strong -Tie LUS24 (4-10d Girder, 2-10d Truss, Single Ply Girder) or equivalent spaced at 2-0-0 oc max. starting at 10-0-12 from the left end to
15-114 to connect truss(es) JOB (1 ply 2 X 4 SPF) to front face of bottom chord.
12) Fill all nail holes where hanger is in contact with lumber.
LOAD CASE(S) Standard
1) Regular: Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plQ
Vert: A-D=-84, D-17=-84, F-I=-84, B-H=-14
Concentrated Loads (lb)
Vert: M=-1019(F) K=-1019(F) 0=-313(F) P=-313(F) Q=-313(F) R=-313(F)
"V
(Job Truss Truss Type Oty Ply
607142-08 �— CJ11��— MONO TRUSS - 2 1
Job Reference o tiona1 . _.
BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 7.030 s Jan 3 02 08 MiTek Industries, Inc. Mon Jul 21 16:36:17 2008 Page 1
A
S - -1-5-0 - 5-7-14
1-5-0 5-7-14
4.1 U120=
5-7-14
5-7-14
Plate Offsets (X,Y): [D_0-3-4Edge]_ _
-- — -_ — -
LOADING (psf) SPACING 2-M CSI
TCLL 35.0 Plates Increase 1.15 TC 0
TCDL 7.0 Lumber Increase 1.15 BC 0
BCLL 0.0 Rep Stress Incr NO WB 0
BCDL 7.0 Code IRC20061TPI2002 (Matrix)
LUMBER
TOP CHORD 2 X 4 SPF 165OF 1.5E
BOT CHORD 2 X 6 DF 180OF 1.6E
WEBS 2 X 4 SPF Stud/Std "Except'
W1 2 X 4 SPF 1654E 1.5E
REACTIONS (lb/size) E=772/Mechanical, B=771/0-7-12
Max Horz B=228(LC 5)
Max UpliftE=-341(LC 5), B=-266(LC 5)
-- - 11-3-12
5-7-14
&S 61120 it
D
_sue
3A Mtl20:= -
4gs�,1i � w1
c
w3 w2
F
3.4 L11120 it
S,6M120=
— -_-- - - _ -
11-3-12 t
5-7-14
DEFL
in (loc)
Well
Ud
PLATES GRIP
34 Vert(LL)
-0.02 F
>999
360
M1120 197/144
19 Vert(TL)
-0.05 E-F
>999
240
70 j Horz(TL)
0.01 E
nla
n/a
Wind(LL)
0.02 F
>999
240
Weight: 53lb
FORCES (lb) - Maximum Compression/Maximum Tension
TOP CHORD A-B=0152, B-G=-1109/317, C-G=-974/317, C-H=-231/67, D-H=-49/36, D-E=-312/183
BOT CHORD B-1=420/965, F-1=420/965, F-J=-420/965, E-J=-420/965
WEBS C-F=01329, C-E=-947/400
Scak a 1.241
BRACING
TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc puriins, except end verticals.
BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES
1) Wind: ASCE 7-05: 90mph; h=25ft; TCDL=4.2psf; BCDL=4.2psf-, Category II; Exp C; enclosed; MWFRS (low-rise) gable end zone: cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33.
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 341 tb uplift at joint E and 266 lb uplift at joint B.
6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
7) Hanger(s) or other connection device(s) shall be provided sufficient to support concentrated load(s) 9 lb down and 29 lb up at 2-10-4, 9 Ib down and 29 lb up at
2-10-4, 38 Ib dawn and 63 lb up at 5-8-3, 38 lb down and 63 Ib up at 5-8-3, and 119 lb down and 116 to up at 8-6-2, and 119 lb down and 116 lb up at 8-6-2 on
top chord, and 1 lb up at 2-10-4, 1 lb up at 2-10-4, 29 lb down at 5-8-3, 29 lb down at 5-8-3, and 63 lb down at 8-6-2, and 63 lb down at 8-6-2 on bottom chord.
The design/selection of such connection device(s) is the responsibility of others.
8) In the LOAD CASE(S) section, loads applied to the face of the truss are noted as front (F) or back (B).
LOAD CASE(S) Standard
1) Regular. Lumber Increase=1.15, Plate Increase=1.15
Uniform Loads (plf)
Vert: A-D=-84, B-E=-14
Concentrated Loads (lb)
Vert: C=-76(F=-38, B=-38) F=-24(F=-12, 8=-12) G=58(F=29, B=29) H=-237(F�119, B=-119)1=1(F=1, B=1) J=-52(F=-26, B=-26)
Job Truss Truss Type Qty ; Ply
1
B07142-08 GE01 GABLE 1 1
Job Reference (optional)
BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 _ vv 7.030 s Jan 3 2008 MiTek Industries, Inc. Mon Jul 21 16:36:19 2008 Page 1
1-0-0 21-3-0 42-6-0 q3-6-0
1-0-0 21-3-0 21-3-0 1-0-0
Scab a 169.9
5-S LU120=
M
L// N
/ O
7.001 12 K • '
J
\ ` P
2- 11
1 \_\Q
,A STm
I 1 R
N j
3.61.0120 u
/ G Iri STD STD �7 S 3,GM1120,1
` I I
T
To
I D V _\ E t9 ! � T I \\
II ST
W
ST
1 A Ii Ii tJ - It it - BS I} Y
i
34 M1120 = AT AS AR AQ AP AO AN AM AL AK Al Al AH AG AF AE AD AC AB AA z 34 M1120=
3* =120 - 3S M1120
--' ' ----- -- - 42-6-0-- -- -- ---- -�
42-6-0
Plate Offsets (X,Y)_[B 0 3-4,0-1 8],[F:0-1-13,0-1-8 , :0-1-13,0.1-8 X:0-3-4,0-1-8
] [T- ---- - -], [ ]
LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) Vdefl Ud PLATES GRIP
TCLL 35.0 Plates Increase 1.15 ; TC 0.13 Vert(LL) 0.00 X nlr 120 M1120 197/144
TCDL 7.0 Lumber Increase 1.15 BC 0.06 Vert(TL) 0.00 Y n/r 120
BCLL 0.0 Rep Stress Incr NO WB 0.21 Horz(TL) 0.02 X n/a n/a
BCDL 7.0 Code IRC2006/TP12002 (Matrix) Weight: 252lb
LUMBER BRACING
TOP CHORD 2 X 4 SPF 165OF 1.5E TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2 X 4 SPF 165OF 1.5E BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2 X 4 SPF Stud/Std WEBS 1 Raw at midpt M-AJ, L-AK, K-AL, J-AN, N-AI, O-AH, P-AF
REACTIONS (lb/size) B=254/42-6-0, AJ=171142-6-0, AK=194/42-6-0, AL=197/42-6-0, AN=196/42-6-0, AO=196/42-6-0, AP=196142-6-0, AQ=194/42-6-0, AR=205/42-6-0, AS=160/42-6-0, AT=295/42-6-0,
AI=194/42-6-0, AH=197142-", AF=196/42-6-0, AE=196142-6-0, AD=196/42-6-0, AC=194142-6-0, AB=205/42-6-0, AA=160142-64), Z=295/42-6-0, X=254/42-6-0
Max Horz 8=-393(LC 3)
Max UpliftB=-105(LC 3), AK=-53(LC 5), AL=-87(LC 5), AN=-77(LC 5), AO=-78(LC 5), AP=-78(LC 5), AQ=-78(LC 5), AR=-80(LC 5), AS=-69(LC 5), AT=-110(LC 5), AI=-46(LC 6), AH=-89(LC 6),
AF=-77(LC 6), AE= 78(LC 6), AD=-78(LC 6), AC=-78(1_C 6), AB=-80(LC 6), AA=-69(LC 6), Z=-109(LC 6), X=-27(LC 4)
Max GravB=254(LC 1), AJ=254(LC 6), AK=201(LC 9), AL=197(LC 1), AN=196(LC 1), AO=196(LC 9), AP=196(LC 1), AQ=194(LC 9), AR=205(LC 1), AS=160(LC 9), AT=295(LC 9), Ai=201(LC 10),
AH=197(LC 1), AF=196(LC 1), AE=196(LC 10), AD=196(LC 1), AC=194(LC 10), AB=205(LC 1), AA=160(LC 10), Z=295(LC 10), X=254(LC 1)
FORCES (Ib) - Maximum Compression/Maximum Tension
TOP CHORD A-8=0/43, B-C=-343/244, C-D=-286/229, D-E=-252/228, E-F=-214/214, F-G=-210/222, G-H=-176/217, H-1=4391213, I-J=-101/226, J-K=-70/265,
K-L=-70/309, L-M=-69/331, M-N=-69/324, N-0=70/283, O-P=-70/222, P-Q=-70/167, Q-R=-70/118, R-S= 70/79, S-T=-57/70, T-U=-70/62,
U-V=-100/75, V-W=-134/77, W-X=-199/91, X-Y=0/43
BOT CHORD B-AT=-64/242, AS-AT=-64/242, AR-AS=-64/242, AQ-AR=-64/242, AP-AQ=-64/242, AO-AP=-64/242, AN-AO=-64/242, AM-AN=-64/242,
AL-AM=-64/242, AK-AL=-64/242, AJ-AK=-641242, AI-AJ=-64/242, AH-AI=-64/242, AG-AH=-64/242, AF-AG=-64/242, AE-AF=-641242,
AD-AE=-64/242, AC-AD=-641242, AB-AC=-64/242, AA-AB=-64/242, Z-AA=-64/242, X-Z=-641242
WEBS M-AJ=-23710, L-AK=-173169, K-AL=-1691104, J-AN=-168194, I-AO=-168/95, H-AP=-168/95, G-AQ=-167194, E-AR=-174/97, D-AS=-143184,
C-AT=-2401132, N-AI=-173163, O-AH=-169/106, P-AF=-168/93, Q-AE=-168/95, R-AD=-168/95, S-AC=-167/94, U-AB=-174/97, V-AA=-143/84,
W-Z=-240/131
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph: h=25ft: TCDL=4.2psf: BCDL=4.2psf: Category 11; Exp C; enclosed: MWFRS (low-rise) gable end zone; cantilever left and right exposed
Lumber DOL=1.33 plate grip DOL=1.33.
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see MTek "Standard Gable End Detail'
4) This truss has been designed for a 10.0 psf bottom chord live load nonooncurrent with any other live loads.
5) All plates are 1.5x4 M1120 unless otherwise indicated.
6) Gable requires continuous bottom chord bearing.
7) Gable studs spaced at 2-0-0 oc.
8) ' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord
and any other members.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 105 lb uplift at joint B, 53 lb uplift at joint AK, 87 lb uplift at joint AL, 77 lb
uplift at joint AN, 78 lb uplift at joint AO, 781b uplift at joint AP, 78 lb uplift at joint AQ, 80 lb uplift at joint AR, 69 lb uplift at joint AS, 110 lb uplift at joint AT, 46 lb uplift
at joint At, 89 lb uplift at joint AH, 77 lb uplift at joint AF, 78 lb uplift at joint AE, 78 lb uplift at joint AD, 78 lb uplift at joint AC, 80 lb uplift at joint AB, 69 lb uplift at joint
AA, 109 lb uplift at joint Z and 27 lb uplift at joint X.
10) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job
Truss
Truss Type
Qty Ply
B07142-08
GE01 A
GABLE
1 1
___- - -
- _ _ -- _ _
� ____ _ _
_ _ _ _ _ _ _
_ _ _ -
_ - --' Job Reference (optional)-
BMC WEST (IDAHO FALLS), tDAHO FALLS, ID 83402
7.030 s Jan 3 2008 MITek Industries, Inc. Mon Jul 21 16:36:21 2008 Page 1
-1-0-0
- 21-3-0
42-6-0
1-0-0
21-3-0
6a6 M1120
21-3-0
Scale a I�69.6
{M {}
N
o
roolu
K
i Ar
0:\
P
\ ,
M.-;Ir'
YI�M
{t'
S710
; Yid--
H
H
34 MI120� -' j
STB
r 1�
STS �\ S 34 M1120:
Ill
`I�
g
�
F
$T6
T
i
T
v
\\
D T�
I
T
'I! i ST
CTI-.= -
I
ST\-
�73-W
..
,
STf
STI
x
! 340120-
4- - U-Bs--'ll-- (1-
AS AR AO AP AO
-i
AN
{F -
AM AL AK
34 M1120=
I} - --
- AI AI
- iFU -i -- -D
AN AG AF AE AD AC AS AA 2 Y 34UM=
34 U320=
�- - -- -- - - - - - 42-6-0 -{
42-6-0
Plate Offsets (X,Y): [B:0-3-4,0-1-8 F:0-1-13,0-1-8 , 0-1-13,0-1-8 X:0-34,0-1-8
LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl Ud PLATES GRIP
TCLL 35.0 Plates Increase 1.15 TC 0.14 Vert(LL) -0.00 A n/r 120 M1120 197/144
TCDL 7.0 Lumber Increase 1.15 BC 0.09 Vert(TL) 0.00 A n/r 120
BCLL 0.0 Rep Stress Ina NO WB 0.21 HOrz(TL) 0.01 X n/a rda
BCDL 7.0 Code IRC2006/TPI2002 (Matrix) Weight: 251 lb
- - - -- -- is --- - - .- - - ------ - - - - ---- -
LUMBER BRACING
TOP CHORD 2 X 4 SPF 165OF 1.5E TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purlins.
BOT CHORD 2 X 4 SPF 165OF 1.5E BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2 X 4 SPF Stud/Std WEBS 1 Row at midpt M-AI, L-AJ, K-AK, J-AM, N-AH, O-AG, P-AE
REACTIONS (lb/size) B=254/42-6-0, AI=171/42-", AJ=194/42-6-0, AK=197/42-M, AM=196/42-6-0, AN=196/42-6-0, A0=196/42-6-0. AP=194/42-", AQ=205/42-6-0, AR=160/42-6-0, AS=295/42-6-0,
AH=194/42-", AG=197/42-6-0, AE=196/42-6-0, AD=196/42-6-0, AC=197/42-6-0, AB=193142-6-0, AA=208/42-6-0, Z=148/42-6-0, Y=325/42-6-0, X=144/42-6-0
Max Horz B=402(LC 4)
Max UpliftB=-103(LC 3), AJ=-53(LC 5), AK=-87(LC 5), AM=-77(LC 5), AN=-78(LC 5), AO=-78(LC 5), AP=-78(LC 5), AQ=-80(LC 5), AR=-69(LC 5), AS=-110(LC 5), AH=47(LC 6). AG=-89(LC 6),
AE=-77(LC 6), AD=-78(LC 6), AC=-78(LC 6), AB=-77(LC 6), AA=-83(LC 6), Z=-59(LC 6), Y=-133(LC 6). X=-14(LC 4)
Max GravB=254(LC 1), A1=242(LC 6), AJ=201(LC 9), AK=197(LC 1), AM=196(LC 1), AN=196(LC 9), A0=196(LC 1), AP=194(LC 9), AQ=205(LC 1), AR=160(LC 9), AS=295(LC 9), AH=201(LC 10),
AG=197(LC 1). AE=196(LC 1), AD=196(LC 10), AC=197(LC 1), AB=193(LC 10), AA=208(LC 1), Z=148(LC 10), Y=325(LC 10), X=144(LC 1)
FORCES (lb) - Maximum Compression/Maximum Tension
TOP CHORD A-B=0/43, B-C=-3471239, C-D=-290/225, D-E=-256/223, E-F=-217/210, F-G=-213/217, G-H=-180/213, H-1=-142/208, I-J=-105/213, J-K=-70/252,
K-L=-70/295, L-M=-69/319, M-N=-69/311, N-0=-70/270, O-P=-70/209, P-Q=-70/153, Q-R=-70/113, R-S=-70/74, S-T=-62/66, T-U=-70/59,
U-V=-105/72, V-W=-138/74, W-X=-216/87
BOT CHORD B-AS=-71/219, AR-AS=-71/219, AO-AR=-71/219, AP-AQ=71/219, AO-AP=-71/219, AN-AO=-71/219, AM-AN=-71/219, AL-AM=-71/219,
AK-AL=-71/219, AJ-AK=-71/219, AI-AJ=-71/219, AH-AI=-71/219. AG-AH=71/219, AF-AG=-71/219, AE-AF=-71/219, AD-AE=-71/219,
AC-AD=-71/219, AB-AC=-71/219, AA-AB=-71/219, Z-AA=-71/219, Y-Z=-71/219, X-Y=-71/219
WEBS M-AI=-226/0, L-AJ=-173/70, K-AK=-169/104, J-AM=-168/94, I-AN=168/95. H-AO=-168/95, G-AP=-167/94, E-AQ=-174/97, D-AR=-143/84,
C-AS=-240/132, N-AH=-173/64, O-AG=-169/106, P-AE=-168/93, Q-AD=-168/95, R-AC=-168/95, S-AB=-167/94, U-AA=-175/98, V-Z=-138/79,
W-Y=-254/142
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; h=25ft; TCDL=4.2psf; BCDL=4.2psf; Category 11; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed
Lumber DOL=1.33 plate grip DOL=1.33.
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see MiTek "Standard Gable End Detail"
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) All plates are 1.5x4 M1120 unless otherwise indicated.
6) Gable requires continuous bottom chord bearing.
7) Gable studs spaced at 2-0-0 oc.
8)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 24)-0 wide will fit between the bottom chord
and any other members.
9) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 103 lb uplift at joint B. 531b uplift at joint AJ, 87 lb uplift at joint AK, 77 lb
uplift at joint AM, 78 lb uplift at joint AN, 78 lb uplift at joint AO, 78 lb uplift at joint AP, 80 lb uplift at joint AQ, 69 lb uplift at joint AR, 110 lb uplift at joint AS. 47 lb
uplift at joint AH, 89 lb uplift at joint AG, 77 lb uplift at joint AE, 78 Ib uplift at joint AD, 78 lb uplift at joint AC, 77 lb uplift at joint AB. 83 lb uplift at joint AA, 59 lb uplift
at joint Z, 133 lb uplift at joint Y and 14 lb uplift at joint X.
10) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job - - - Truss - Truss Type
607142-08 GE02 (GABLE
BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
=1-0-0 } -- — ----- 4-6-0- -
1-0-0 4-6-0
r
A
-- - — Qty pty —�--
1 1
Job Reference (optional)
7.030 s Jan 3 2008 MTek Industries, Inc. Mon Jul 21 16:36:22 2008 Page 1
} 9-0-0
4-6-0
scab - 1:171
44 M1120 --
0
t 5,A LAW,, / 1.5r4 M1120 ' 1
E
7.00112
ST2 �\
3*4 M1120 — 1534 M112011 1.5A M1120 1, 1.5A L9120 11 3a4 M1120-
F------- - 9-0-0 -- i
9-0-0
LOADING (psf) SPACING 2-" CSI DEFL in (loc) l/defl Ud PLATES GRIP
TCLL 35.0 Plates Increase 1.15 TC 0.11 Vert(LL) -0.00 G nlr 120 M1120 197/144
TCDL 7.0 Lumber Increase 1.15 BC 0.04 Vert(TL) -0.00 G n/r 120
BCLL 0.0 Rep Stress Incr NO WS 0.06 Horz(TL) 0.00 F n/a nla
BCDL 7.0 Code IRC20061TPI2002 (Matrix) Weight: 31 lb
LUMBER BRACING
TOP CHORD 2 X 4 SPF 165OF 1.5E TOP CHORD Structural wood sheathing directly applied or 6-0-0 oc purtins.
BOT CHORD 2 X 4 SPF 165OF 1.5E BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
OTHERS 2 X 4 SPF Stud/Std
REACTIONS (lb/size) B=222/9-0-0, F=222/9-0-0, 1=130/9-0-0. J=244/9-0-0, H=244/940-0
Max Horz B=-86(LC 3)
Max UpliftB=-83(LC 5), F=-94(LC 6), J=-87(LC 5), H=-87(LC 6)
FORCES (lb) - Maximum Compression/Maximum Tension
TOP CHORD A-B=0/43, B-C=-74/61, C-D=-71/79, D-E=-71171, E-F=-74142, F-G=0/43
BOT CHORD B-J=-10166,1-J=-10/66, H-1=-10/66, F-H=-10/66
WEBS D-1=-108/2, C-J=-206/110, E-1-1�2061110
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05-. 90mph; h=25ft: TCDL=4.2psf; BCDL=4.2psf; Category 11; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed , Lumber DOL=1.33 plate grip DOL=1.33.
3) Truss designed for wind loads in the plane of the truss only. For studs exposed to wind (normal to the face), see MiTek "Standard Gable End Detail'
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) Gable requires continuous bottom chord bearing.
6) Gable studs spaced at 2-0-0 oc.
7) ' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord
and any other members.
8) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 83 Ib uplift at joint B, 94 lb uplift at joint F, 87 lb uplift at joint J and 87 lb
uplift at joint H.
9) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/'TPI 1.
LOAD CASE(S) Standard
F1d
Job Truss Truss Type
B07142-08 H01 HIP
BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
Ply
Job Reference
7.O3OsJan 32008MiTek Industries, Inc. Mon Jul 2116:36:232008 Pagel
,-1-0-0 5-0-0 10-0-0
1-0-0 5-0-0 5-0-0
16-0-0 21-0-0
6-0-0 5-0-0
26-0-0
5-0-0
40 LU120 10A0 M1120 :
E
7 00 r-1 1 1.5'4M:120
w ,' `Yz 1,5*4 Ltll2or'
W1
\ `\\
71
W3
13
02---
A
516 M1120 34 W120 = 5SM1120=
5.6 L11120
27-0-0
1-0-0
Scae - 1:44 4
10-0-0 16-0-0 26-0-0
10-0-0 6-0-0 10-0-0
Plate Offsets- (X.y): [P*.04:8!0!2-0],[E,0-64,0-1-12]. [G:0-1-7.Edge],_[I:9A0,0Q-0]_
LOADING SPACING 2-0-0 CS1 DIEFIL in (loc) Udell L/d PLATES GRIP
TCLL 35.0 Plates Increase 1.15 TC; 0.39 Vert(LL) -0.23 G-1 >999 360 M1120 1971144
TCDL 7.0 Lumber Increase 1.15 BC 0.45 Vert(TL) -0.50 G-1 >617 240
BCLL 0.0 II, Rep Stress Incr YES WB 0.28 Horz(TL) 0.07 G n/a n/a
BCDL 7.0 Code IRC2006ITP12002 (Matrix) Wind(LL) 0.04 B-J >999 240 Weight: 101 lb
LUMBER BRACING
TOP CHORD 2 X 4 SPF 1650F 1.5E TOP CHORD Structural wood sheathing directly applied or 4-8-11 oc purlins.
BOT CHORD 2 X 4 SPF 1650F 11.5E BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2 X 4 SPF Stud/Std
REACTIONS (lb/size) B=1361/0-5-8, G=1361/0-5-8
Max Horz B=l 87(LC 4)
Max UpliftB=-314(LC 5), G=-314(LC 6)
FORCES (1b) - Maximum CornpressionlMaximurn Tension
TOP CHORD A-B=0/45.B-C=-2004/409,C-D=-1630/320,D-E=-1325/329.E-F=-1630/320,F-G=2004/409,G-H--0/45
BOT CHORD B-J=-337/1646, I-J=-127/1324, G-I=-243/1646
WEBS C-J=-377/219, D-J=-351317, E-J=-2051206, E-1=401317, F-I=-377/219
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05: 90mph; h=25ft; TCDL=4.2psf-, BCDL=4.2psf; Category 11; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed Lumber DOL=1.33 plate grip DOL=l .33.
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) * This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord
and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 314 lb uplift at joint B and 314 lb uplift at joint G.
7) This truss is designed in accordance with the 2006 International Residential Code sections R502.1 1.1 and R802.10.2 and referenced standard ANSIfTPl 1.
LOAD CASE(S) Standard
Job Truss Truss Type Oty - Ply ---- --
607142-08 H02 HIP 1 1
Job Reteren_ce (optional)
BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 63402 _ - 7.030 s Jan 3 2008 MiTek Industries, Inc. Mon Jul 21 16:36:24 2008 Page 1
-1-0-0, 6-0-0 - -, 12-0-0 14-M 20-0-0 26-0-0 i27 —
1-M 6-0-0 6-0-0 2-0-0 "_0 6-0-0 1-0-0
Scale - 1:44-4
0x0101120-:
54 MIMI
D E
7.00R2 US141120%
c .�
,i. 71
1 \
W3
A -
-- - -
✓=J L K J
536 FAMD= 1.5A L4120 11 Sr6 W120 = 3d AS120 =
1
1.5s4 AD12011
G
S.6 L0120=
6-0-0 12-0-0 14-0-0 20-0-0 26-0-0
6-0-0 6-0-0 2-0-0 6-0-0 6-0-0
Plate Offsets (X,Y); [B:0-1-3,Ed eJ, [D:0-4-0,1)-1-11], [E:0-3-4,0-2-4Gj_0.1-3,Edgej, [K:0 3-0.0-3-0j - - - _ -- - - --- —
_—
LOADING (psf) SPACING 2-M CSI DEFL in (loc) Udell Ud PLATES GRIP
TCLL 35.0 Plates Increase 1.15 TC 0.44 Vert(LL) -0.09 K >999 360 M1120 197/144
TCDL 7.0 Lumber Increase 1.15 BC 0.39 Vert(TL) -0.17 K-L >999 240
BCLL 0.0 Rep Stress Ina YES WB 0.62 Horz(TL) 0.07 G nla n/a
BCDL 7.0 Code IRC2006/TPI2002 (Matrix) Wind(LL) 0.05 K >999 240 Weight:113 lb
LUMBER BRACING
TOP CHORD 2 X 4 SPF 165OF 1.5E TOP CHORD Structural wood sheathing directly applied or 4-7-2 oc purlins.
BOT CHORD 2 X 4 SPF 165OF 1.5E BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2 X 4 SPF Slud/Std
REACTIONS (Ib/size) B=1361/0.5-8, G=1361/0-5-8
Max Horz B=224(LC 4)
Max UpliftB=-324(LC 5), G=-324(LC 6)
FORCES (lb) - Maximum Compression/Maximum Tension
TOP CHORD A-B=0/45, B-C=-2048/392, C-D=-1452/328. D-E=-1146/338, E-F=-1455/329, F-G=-2046/393, G-H=0145
BOT CHORD B-L=-330/1647, K-L=-33011647, J-K=-121/1144,1-J=-22211646, G-1= 222/1646
WEBS C-L=0/225, C-K=598/243, D-K=-86/338, D-J=263/279, E-J=-102/401, F-J=-595/243, F-1=01223
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; h=25ft; TCDL=4.2psf; BCDL=4.2psf; Category II; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33.
3) Provide adequate drainage to prevent water ponding.
4) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
5) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord
and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 324 lb uplift at joint B and 324 lb uplift at joint G.
7) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
Truss - - - - ;Truss Type
I
807142-08 J01 MONO TRUSS
BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
- --- - - Oly 'Ply ; - - — -- - - - - --
4 1
�JokRqlg�rence (gRbcnalJ_ _
7.030 s Jan 3 2008 MiTek Industries, Inc. Mon Ju121 16:36:24 2008 Pagel
scale - 1 8 3
LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) I/defl Ud I PLATES GRIP
TCLL 35.0 I Plates Increase 1.15 TC 0.10 Vert(LL) -0.00 B >999 360 M1120 197/144
TCDL 7.0 Lumber Increase 1.15 BC 0.03 Vert(TL) -0.00 B-D >999 240
BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0,00 C n/a n1a
BCDL 7.0 Code IRC2006/TPI2002 (Matrix) Wind(LL) 0.00 B """" 240 i Weight: 6 lb
LUMBER BRACING
TOP CHORD 2 X 4 SPF 165OF 1.5E TOP CHORD Structural wood sheathing directly applied or 1-11-11 oc purtins.
BOT CHORD 2 X 4 SPF 165OF 1.5E BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (Iblsize) B=214/0-5-8, D=13/Mechanical, C=51/Mechanical
Max Horz B=83(LC 5)
Max UpliftB=-86(LC 5), C=-25(LC 5)
Max GravB=214(LC 1), D=33(LC 2), C=51(LC 1)
FORCES (lb) - Maximum Compression/Maximum Tension
TOP CHORD A-B=0/43, B-C=-56/19
BOT CHORD B-D=0/0
NOTES
1) Wind: ASCE 7-05; 90mph; h=25ft; TCDL=4.2psf; BCDL=4.2psf-, Category II; Exp C. enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33.
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) " This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 86 lb uplift at joint B and 25 lb uplift at joint C.
6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TP11.
LOAD CASE(S) Standard
Truss I Truss Type
B07142-08 J03 MONO TRUSS
BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
-1-0-0-
1-0-0
4 1
_—I -_ Job Reference (optional) _
7.030 s Jan 3 2008 MiTek Industries, Inc. Mon Jul 21 16:36:25 2008 Page 1
3-11-11
3-11-11
,fI Scab = 1.13.0
7 00 jig
/
Tt
i
6t
N
D
3A M1120 =
i -- - - --- 3-11-11 - --- i
_ 3-11-11 _
LOADING (psf) SPACING 2-0-0 CSI DEFL in (foe) Udefl Ud I PLATES GRIP
TCLL 35.0 Plates Increase 1.15 TC 0.17 Vert(LL) -0.01 B-D >999 360 M1120 197/144
TCDL 7.0 Lumber Increase 1.15 BC 0.10 Vert(TL) -0.02 B-D >999 240
BCLL 0.0 Rep Stress Incr YES WB 0.00 Horz(TL) -0.00 C Na n/a
BCDL 7.0 l Code tRC2006/TPI2002 (Matrix) Wind(LL) 0.00 B "" 240 — - Weight: 11 lb
LUMBER BRACING
TOP CHORD 2 X 4 SPF 165OF 1.5E TOP CHORD Structural wood sheathing directly applied or 3-11-11 oc purlins.
BOT CHORD 2 X 4 SPF 1650F 1.5E BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size) C=127/Mechanical, B=303/0-5-8, D=261Mechanical
Max Horz B=127(LC 5)
Max UpliftC=-73(LC 5), B= 93(LC 5)
Max GravC=127(LC 1), 6=303(LC 1). D=63(LC 2)
FORCES (lb) - Maximum Compression/Maximum Tension
TOP CHORD A-13=0/45, B-C=-90/52
BOT CHORD B-D=0/0
NOTES
1) Wind: ASCE 7-05; 90mph; h=25ft; TCDL=4.2psF, BCDL=4.2psf, Category II; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33.
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other We loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 73 lb uplift at joint C and 93 lb uplift at joint B.
6) This truss is designed In accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSUTPI 1.
LOAD CASE(S) Standard
Job Truss Truss Type Qty Pty
1B07142-08 J05 I MONO TRUSS 4 1
Job Reference (optional)_-
BMC WEST (IDAHO FALLS), IDAFtO FALLS, ID 83402 7.030 s Jan 32008 MiTek Industries, Inc. Mon Jul 21 16:36:26 2008 Pagel
-1-0-0 -- 5-11-11
1-0-0 5-11-11
Scab 1:18.3
I
7.00! 12
i
N
d
'Ti
BI
3iA Mg20
5-11-11
5-11-11
LOADING (psf) SPACING 2.0-0 CSI DEFL in (!oc) lldefl Ud I PLATES GRIP
TCLL 35.0 Plates Increase 1.15 ` TC 0.51 Vert(LL) -0.06 B-D >999 360 MI120 197/144
TCDL 7.0 Lumber Increase 1.15 BC 0.24 Vert(TL) -0.12 B-D >570 240
BCLL 0.0 i Rep Stress Incr YES I WB 0.00 Horz(TL) -0.00 C n/a Ma j
BCDL 7.0 Code IRC20061TP12002 (Matrix) Wind(LL) 0.00 B "" 240 Weight: 16lb
LUMBER BRACING
TOP CHORD 2 X 4 SPF 1650F 1.5E TOP CHORD Structural wood sheathing directly applied or 5-11-11 oc purlins.
BOT CHORD 2 X 4 SPF 1650F 1.5E BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
REACTIONS (lb/size) C=219/Mechanical, B=394/0-5-8, D=401Mechanical
Max Herz B=175(LC 5)
Max UpliftC=-126(LC 5).13 -99(LC 5)
Max Grav C=219(LC 1), B=394(LC 1), D=97(LC 2)
FORCES (lb) - Maximum Compression/Maximum Tension
TOP CHORD A-B=0/45, B-C=-128/90
BOT CHORD B-D=0/0
NOTES
1) Wind: ASCE 7-05; 90mph; h=25ft; TCDL=4.2psf; BCDL=4.2psf; Category II; Exp C; enclosed; MWFRS (!ow -rise) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33.
2) This truss has been designed for a 10.0 psf bottom chord We load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 240-0 wide will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 126 lb uplift at joint C and 99 lb uplift at joint B.
6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSIITPI 1.
LOAD CASE(S) Standard
i Job - - -- Truss — Truss Type -
`B07142-08 J08 MONO TRUSS
BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
4-0-0
1-0-0 4-0-0
e
3A Mn20
LOADING (psf) SPACING 2-0-0
TCLL 35.0 Plates Increase 1.15
TCDL 7.0 Lumber Increase 1.15
BCLL 0.0 Rep Stress Incr YES
BCDL 7.0 Code IRC2006/TPI2002
LUMBER
TOP CHORD 2 X 4 SPF 165OF 1.5E
BOT CHORD 2 X 4 SPF 240OF 2.0E
WEBS 2 X 4 SPF Stud/Std
REACTIONS (lb/size) E=364/Mechanical, B=492/0-5-8
Max Horz B=227(LC 5)
Max Up11ftE=-146(LC 5). B=-108(LC 5)
FORCES (lb) - Maximum Compression/Maximum Tension
TOP CHORD A-B=0/45. B-C=435/44. C-D=-101/51, D-E=-135176
BOT CHORD B-E=178/307
WEBS C-E=-3531205
--- Oly Ply I -- - — -- —
6 1
Job Reference (optional)-____ -.
7.030 s Jan 3 2008 MSiTek Industries, Inc. Mon Jul 21 16:36:26 2008 Pagel
- - --- "_0
4-0-0
sca%-1:2s.s
1.5.+M1120 iI
I
I
1.3.4 M1120�' 7.00112
'W11
i
E
3-1 LU120 =
8-0-0
8-0-0
CSI DEFL in
(loc)
Well L/d
PLATES GRIP
TC 0.24 Vert(LL) -0.14
B-E
>645 360
MII20 197/144
BC 0.30 Vert(TL) -0.29
WB 0.17 Horz(TL) 0.00
B-E
E
>315 240
n/a rVa
(Matrix) Wind(LL) 0.00
B
""` 240
Weight: 31 lb
-
BRACING
_
- _ - -
TOP CHORD
Structural wood sheathing directly applied or 6-0-0 oc purlins, except end verticals.
BOT CHORD
Rigid ceiling directly applied or 10-0-0 oc bracing.
NOTES
1) Wind: ASCE 7-05; 90mph; h=25ft; TCDL=4.2psf; BCDL=4.2psf; Category II; Exp C: enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33.
2) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
3) ' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members.
4) Refer to girder(s) for truss to truss connections.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 146 ib uplift at joint E and 108 lb uplift at joint B.
6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job - Truss
Truss Type
oty 1 Ply
B07142-08 Tot
COMMON
1 1
1
IJobReference(optional) V
BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
7.030 s Jan 3 2008 MiTek Industries, Inc. Mon Jul 21 16:36:27 2008 Page 1
-1-0-0 - -----7-1-0 - - -
14-2-0-
-- 21-3-0
2-8-4-0 -- 35-5-0 - 42-6-0
43-6 -0
1-0-0 7-1-0
7-1-0
7-1-0
7a10 MII16H
7-1-0 7-1-0 7-1-0
1-0-0
Sc%- 1.697
7.00112
it
73
5X8 M3120
-
6S M1120�
\\
y
\
di
5a5 PA120
T2
i
W 2
\\\ SX10 M7120'�
W3 ,,, \ `�
W S
we
w6,,
Z`
% ` w9
Tr
.
T6
� v1 B
. �A ` .'-------------- -fit._-
—
.f.
_ _ `J_
� -- - - B2
--
�. ----
1 i _
r
-'---- � - - - -- - I_t�T�-� —�--- _ --___
\ H
\ I ly
54 M1120 - N
1.5.4 Mi120'
M O
5,6M1120-
L
6,010120 -
G
P O K J
6.12M1120= 1-5A M:120''
5,6 M1120 -
7-1-0
-14-2-0
-
21-3-
- 0
-
30-9-4 } 36-7-10 } 42-6-0
- - - -- --
7-1-0
7-1-0
7-1-0
9-6-4 5-10-6 5-10-6
Plate Offsets (X,Y,_[B_0-1-8,Edge], [Q04-0,0-3-0],
(D_0470,0-3-0), [F.0-34,Edge],[G:0-5-0,0-3_4]_LH:0-1-3,Edge],[L:0-4-0,0-3.4], [M:0-3-0,0-3-Oj
LOADING (psf) i SPACING
24)-0
CSI
DEFL
in (loc) Udefl Ud
PLATES GRIP
TCLL 35.0 Plates Increase
1.15
TC 0.67
Vert(LL)
-0.28 K-L >999 360
M1120 197/144
TCDL 7.0 Lumber Increase
1.15
BC 0.68
Vert(TL)
-0.45 K-L >808 240
MI118H 141/138
BCLL 0.0 Rep Stress Incr
YES
WB 1.00
Horz(TL)
0.06 K n/a nla
BCDL 7.0 Code IRC2006/TPI2002
(Matrix)
Wind(LL)
0.08 B-N >999 240
Weight: 189 Ib
LUMBER
BRACING
TOP CHORD 2 X 4 SPF 165OF 1.5E
TOP CHORD Structural wood sheathing directly applied or 3-9-9 oc pudins.
BOT CHORD 2 X 4 SPF 165OF 1.5E
BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 2 X 4 SPF Stud/Std
WEBS
1 Raw at midpt C-M, D-L, F-K
REACTIONS (lb/size) B=158010-5-8, K=276210-5-8, H=346/0-5-8
Max Horz B=393(LC 4)
Max UpliftB=-368(LC 5). K=481(LC 6). H=-149(LC 6)
Max GravB=1580(LC 1), K=2762(LC 1), H=491(LC 10)
FORCES (lb) - Maximum Cornpression/Maximum Tension
TOP CHORD A-B=0/45, B-C=-2416/462, C-D=-1726/383, D-E=-985/327, E-F=-989/328, F-G=-81/768, G-H=-342/390, H-1=0/45
BOT CHORD B-N=44211946, M-N=-442/1944, M-0=-224/1355, L-0=-224/1355, L-P=-37/196, P-Q=-37/196, K-Q=-37/196, J-K=-3171157, H-J=-3061176
WEBS C-N=01261, C-M=-682/283, D-M=-88/537, D-L=-10081373, E-L�1121325, F-L=-133/1011, F-K=-2177/448, G-K=-611/290, G-J=0/191
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; h=25ft; TCDL=4.2psf, BCDL=4.2psf: Category II; Exp C; enclosed: MWFRS (law -rise) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) All plates are MT20 plates unless otherwise indicated.
5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord
and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 368 lb uplift at joint B, 481 lb uplift at joint K and 149 lb uplift at joint H.
7) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
(Job___ — —Truss — -- - Truss Type -- — — Oty Ply -- --
B07142-08 T01 A COMMON I Al _ __ _1 Job Reference (optional
BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402 J 7.030 s Jan 3 2008 MTek Industries. Inc. Mon Jul 21 16:36:28 2008 Page 1
-1-0-0 7-1-0 14-2-0 21-3-0 28-4-0 35-5-0 42-6-0
1-0-0 7-1-0 7-1-0 7-1-0 7-1-0 7-1-0 7-1-0
sew* -1Coa
7rt0 M1116H=
E
sm FAUD -
M
1.541 W20 Ii
r�
t
Sd M020
it
6A M1120 -=
602 M1120 = 1.5A 411120
1!
7-1-0 14-2-0 21-3-0 30-9-4 36-7-10 42-6-0
7-1-0 7-1-0 7-1-0 9-6-4 5-10-6 5-10-6
------------ -- ------ - --
Plate Offsets -1-8,Edge . C:0-4-0z0-3_0]. [D 0-4-0.0-3-% [F:0-34.Edgej
LOADING {psf} — - I -- — - -SPACING 2-0-0 --� - 1— -- - CSI--- — -� -- DEFL in (loc) l/defl Ud - � PLATES GRIP -- -
TCLL 35.0 1 Plates Increase 1.15 TC 0.66 Vert(LL) -0.28 J-K >999 360 M1120 197/144
TCDL 7.0 Lumber Increase 1.15 BC 0.68 Vert(TL) -0.46 J-K >805 240 M1118H 141/138
BCLL 0.0 Rep Stress Incr YES WB 1.00 Horz(TL) 0.06 J n/a n/a
BCDL 7.0 Code IRC20061TP12002 (Matrix) Wind(LL) 0.08 B-M >999 240 Weight: 188lb
LUMBER BRACING
TOP CHORD 2 X 4 SPF 165OF 1.5E TOP CHORD Structural wood sheathing directly applied or 3-9-10 oc purlins.
BOT CHORD 2 X 4 SPF 165OF 1.5E BOT CHORD Rigid ceiling directly applied or 6-0-0 oc bracing.
WEBS 2 X 4 SPF Stud/Std WEBS 1 Row at midpt C-L, D-K, F-J
REACTIONS (lb/size) B=1579/0-5-8, J=2772/0-5.8, H=228/0-5-8
Max Horz B=402(LC 4)
Max UpliftB=-366(LC 5), J=-500(LC 6), H=-111(LC 9)
Max Grav B= 1 579(LC 1), J=2772(LC 1), H=373(LC 10)
FORCES (lb) - Maximum CompressiorVMaximum Tension
TOP CHORD A-B=0/45, B-C=-2414/459, C-D=-1724/380, D-E=-9831320, E-F=-987/325, F-G=-88/773, G-H=350/388
BOT CHORD B-M=-452/1944, L-M=453/1942, L-N=-232/1353, K-N=-232/1353, K-O=-38/175, O-P=-38/175, J-P=-38/175, I-J=-315/164, H-i=-305/186
WEBS C-M=0/261, C-L=-682/283, D-L=-88/537, D-K=-1008/373, E-K=-1091324, F-K=-13711014, F-J=-2179/454, G-J=-6261301, G-1=0/193
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; h=25ft; TCDL=4.2psf; BCDL=4.2psf; Category 11; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) All plates are MT20 plates unless otherwise indicated.
5) - This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord
and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 366 lb uplift at joint B. 500 lb uplift at Joint J and 111 lb uplift at joint H.
7) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSVTPI 1.
LOAD CASE(S) Standard
Job Truss -- -
iTruss Type-
i
807142-08 T01 B
� COMMON
7
1
_ I
- _
Job Reference o tional
BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
7.030 s Jan 3 2008 MTek Industries. Inc. Mon Jul 21 16:36:30 2008 Page 1
,1-0-0 7-1-0 - 14-2-0
_ — 21-3-0
28-4-0 35-5-0 42-6-0
1-0-0 7-1-0 7-1-0
7-1-0
7-1-0 7-1-0 7-1-0
Scalp = 1696
SA M1120 -
7 00,12-�-r,1...-.
E
T3..-_
5,6 M1120'
--_'- 5+6 MI120_•.
r
W1
w/
•V
5.5 U120 '
W3
W2
5.5 Lum
W2 W3
c
w4
T/
N 9 -- —
H
!�
5.6 M1120- L GI
7/9 M1120-- SI6 M1120
N K O
642 M1120-
P J O R I 5.diW20=
602 M1120= US M1120 - 70 M1120=
8-6-0
17-0-0--
25-6-0 34-0-0 — 42-6-0
8-6-0
8-6-0
8-6-0 8-6-0 8-6-0
Plate Offsets (X,Y).- [6:0-1-3,Edge], [B:0-7-5,0-1-0], [C_0-4-0,U-3.0]LD:0.4-0.0-3-0], F�:O 4-0,0 3 0]_[G`0-4-O,a3-0] jH 0-7-5 0-1-0j, LH 0-1-3,Edge 04-0,0-3-4], [L_0-4-0--
LOADING (psf) SPACING 2-0-0
CSI l
DEFL in (!oc) !lde0 Ud I PLATES GRIP
TCLL 35.0 Plates Increase 1.15
TC 0.79
Vert(LL) -0.45 K-L >999 360 M1120 1971144
TCDL 7.0 Lumber Increase 1.15
I BC 0.88
Vert(TL) -0.66 J-K >763 240
I
BCLL 0.0
Rep Stress Incr YES
WB 0.76
Horz(TL) 0.21 H n/a rVa
BCDL 7.0
Code IRC2006/TP12002
(Matrix)
Wind(LL) 0.15 H-1 >999 240
I Weight: 193lb
LUMBER
BRACING ` -- -- — - — - — -- — -- -- -
TOP CHORD 2 X 4 SPF 165OF 1.5E
TOP CHORD Structural wood sheathing directly applied or 24-0 oc purlins.
BOT CHORD 2 X 4 SPF 1650F 1.5E
BOT CHORD Rigid ceiling directly applied or 8-6-11 oc bracing.
WEBS 2 X 4 SPF Stud/Std
WEBS 1 Row at midpt D-K, E-K, E-J, F-J
WEDGE
Left: 2 X 8 DF SS, Right: 2 X 8 DF SS
REACTIONS (lb/size) B=246410-5-8, H=2351/0-5-8
Max Horz B=402(LC 4)
Max UpliftB=-499(LC 5). H=432(LC 6)
FORCES (Ib) - Maximum Compressi(NMaximum Tension
TOP CHORD A-13=0/45, B-C=41101720, C-D=-39011803, D-E=-30681692, E-F=-30691694, F-G=-3915/816, G-H=41231731
BOT CHORD B-L=-677/3394, L-M=-445/2807, M-N=-44512807, K-N=-445/2807, K-O=-202/2124, O-P=-202/2124, J-P=-202/2124, J-Q=-333/2810, O-R=-333/2810, I-R=-333/2810, H-1=-531/3408
WEBS C-L=463/282, D-L=-2431782, D-K=-896/410, E-K=-332/1261, E-J=-334/1265, F-J=-9011414, F-I=-255/798, G-1=4701287
NOTES
1) Unbalanced roof We loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; h=25ft; TCDL=4.2psf; BCDL=4.2psf; Category 11; Exp C; enclosed; MWFRS (!ow -rise) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) " This truss has been designed for a live load of 20.Opsf on the bottom chord in ail areas where a rectangle 3-6-0 tail by 2-0-0 wide will fit between the bottom chord
and any other members.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 499 lb uplift at joint B and 432 Ib uplift at joint H.
6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSIITPI 1.
LOAD CASE(S) Standard
Joti
l Truss
, Tnlss Type
Qty
1 Ply
-- -
607142-08
COMMON
6
1
-'T01C
Job Reference (o Eional
BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
7.030 s Jan 3 2008 MTek Industries. Inc.
Mon Jul 21 16:36:31 2008 Page 1
7-1-0 14-2-0
21-3-0 284-0
35-5-0
42-6-0
7-1-0 7-1-0
7-1-0 7-1-0
7x10 MIII6H-
7-1-0
7-1-0
scdo =1.66 6
DD
7.00(12
Sd Mt120 -� -�
Sm
M1120�
c j
-
\� -
E
w1 w1
see Mlrzo
�slzo.�
� ss
w3
W2
W2
w3
IN4
71
W4'
\�
\�Ti
-
G
6+6t.0120=
7,S M1120 -
K L
5�A MII20 -
M J N O 1
6X12 M1120- 6x12 M020 ; -
P
O H
Sxs M1120 -
66M1120=
74 M020=
8-&0 }
17-0-0 { _ _ 25-6-0 _ - - { -
34-0-0
42-6-0 I
8-6-0
8-6-0 8-6-0
8-6-0
8-6-0
Plate Offsets (X_}Y _ [A:0-1-3Edge], [A:0-7-5,0-1-0], LB:O-4-U-3-0 :0-4-0,0-3-0], [E:0-4-2,0-3-0], 0.4-0,0-3-0],_ G:0[ 7-5,0-1-0),
--- - -
[G 0-1-3,Edge],_ H:0-4-0,0-3-4],
_
LOADING (psf)
SPACING 2-0-0
CSI
DEFL in (loc)
Udell
Ud
PLATES
GRIP
TCLL 35.0
Plates Increase 1.15
TC 0.79
Vert(LL) -0.44 J-K
>999
360
M1120
197/144
TCDL 7.0
Lumber Increase 1.15
BC 0.88
Vert(TL) -0.66 I-J
>760
240
M1118H
1411138
BCLL 0.0
( Rep Stress Incr YES
WB 0.76
Horz(TL) 0.21 G
n/a
n/a
BCDL 7.0
Code IRC2006/TP12002
(Matrix)
Wind(ILL) 0.15 A-K
>999
240
Weight: 191 lb
LUMBER
TOP CHORD 2 X 4 SPF 165OF 1.5E
BOT CHORD 2 X 4 SPF 165OF 1.5E
WEBS 2 X 4 SPF Stud1Std
WEDGE
Left: 2 X 8 DF SS, Right: 2 X 8 DF SS
REACTIONS (Ihfsize) A=2353/0-5.8, G=2353/0-5-8
Max Harz A=390(1.0 3)
Max UpliftA=-433(LC 5), G=-433(LC 6)
BRACING
TOP CHORD Structural wood sheathing directly applied or 2-4-0 oc purfins.
BOT CHORD Rigid ceiling directly applied or 8-4-7 oc bracing.
WEBS 1 Row at midpt C-J, D-J, D-I, E-I
FORCES (Ib) - Maximum CompressiordMaximum Tension
TOP CHORD A-B=-4126/732. B-C=-3918/816, C-D=-3072/695, D-E=-3072/695, E-F=-3918/817, F-G=-4126/732
BOT CHORD A-K=-689/3411, K-L=-449/2813, L-M=-44912813, J-M=-44912813, J-N=-204/2127, N-0=-204/2127.1-0=-204/2127,1-P=-335/2813, P-Q=-335/2813, H-Q=-335/2813, G-H=-532/3411
WEBS B-K=-4701287, C-K=-255J798, C-J=-901/414, D-J=-334/1265, D-1=-334/1265, E-1=-901/414, E-H=-2551798, F-H=-470/287
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; h=25ft; TCDL=4.2psf; BCDL=4.2psf; Category 11; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) All plates are MT20 plates unless otherwise indicated.
5)' This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord
and any other members.
6) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 433 lb uplift at joint A and 433 lb uplift at joint G.
7) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSIITPI 1.
LOAD CASE(S) Standard
S%00�
!Job . - .- --- ITruss —
B07142-08 T01 D
BMC WEST (IDAHO FALLS). IDAHO FALLS, ID 83402
-1-0-0 - 7-1-0 - _- 14-2-0
1-0-0 7-1-0 7-1-0
Truss Type --- --- Qtyy Ply
COMMON �3 1
Job Referencen�_ (optfo_
7.030 s Jan 3 2008 MiTek Industries, Inc. Mon Jul 21 16:36:32 2008 Page 1
i 21-3-0 } 28-4-0 35-5-0 42-6-0 43-67i0
7-1-0 7-1-0 7-1-0 7-1-0 1-0-0
Scale - 1.%7
Sig M120 -
E
7.00, 12
T3" i T3
SO W120-' -
" - Sd M020:
D �� F
W1 W1 \
d; T2
WNW
W3 V12 W': W3
W4
I�
6 1-"
- --
Sig M1120 = M N O L P Q K R S J
7d W120= Sd W120 = 602 MI120 = 602 M1120 536 W20=
5d M1120
54 M1120
7dM120-
8-6-0 - 17=0-0 - - — 25-6-0 - -- 34-0-0 42-6-0
- - - - - - -f- - -- ---
8-6-0 8-6-0 8-6-0 8-6-0 8-6-0
- --- --- --- -
— — - -
Plate Offsets- - (X,Y)_ _[F-.047 ,0-3-01 [G-0-4-0,0-3.0], jH 0-7-5,0-1-0],_ H:0-1-3�,, �J-"-0 0_3�j, jM-0-4-0.0-3-4]
LOADING (psf) I SPACING 2-0-0 CSI DEFL in (loc) Ildefl Ud PLATES GRIP
TCLL 35.0 Plates Increase 1.15 TC 0.75 Vert(LL) -0.45 L-M >999 360 M1120 197/144
TCDL 7.0 Lumber Increase 1.15 BC 0.88 Vert(TL) -0.66 K-L >767 240
BCLL 0.0 Rep Stress Incr YES WB 0.76 Horz(TL) 0.21 H n/a nla
BCDL 7.0 Code IRC2006/TP12002 (Matrix) Wind(LL) 0.15 K-L >999 240 Weight: 194 lb
LUMBER BRACING
TOP CHORD 2 X 4 SPF 165OF 1.5E TOP CHORD Structural wood sheathing directly applied or 2-5-14 oc purlins.
BOT CHORD 2 X 4 SPF 165OF 1.5E BOT CHORD Rigid ceiling directly applied or 10-M oc bracing, Except:
WEBS 2 X 4 SPF Stud/Std 8-7-12 oc bracing: B-M.
WEDGE WEBS 1 Row at midpt D-L, E-L, E-K, F-K
Left: 2 X 8 DF SS, Right: 2 X 8 DF SS
REACTIONS (lb/size) B=2462/0-5-8, H=2462/0-5-8
Max Horz B=393(LC 4)
Max UpliflB=498(LC 5), H=498(LC 6)
FORCES (lb) - Maximum CompressiordMaximum Tension
TOP CHORD A-B=0/45, B-C=4107l719, C-D=-3897/803, D-E=-3064/691, E-F=-3064/691, F-G=-3897/803, G•H=4107/719, H-1=0/45
BOT CHORD B-M=-663/3391, M-N=-431/2804, N-0=-431/2804, L-0=-431/2804, L•P=-188/2121, P-Q=-188/2121, K-Q=-188/2121, K-R=-318/2804, R-S=-318/2804, J-S=-318/2804, H-J=-485/3391
WEBS C-M=463/282, D-M=-2431782, D-L=-896/410, E-L=332/1261, E-K=-33211261, F-K=-896/410, F-J=-243/782, G-J=463/282
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; h=25ft; TCDL=4.2psf; BCDL=4.2psf; Category II; Exp C. enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) " This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord
and any other members.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 498 lb uplift at joint B and 498 Ib uplift at joint H.
6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
ij
•
� Job - - - — -Truss _ - ----- - -- --Truss Type - - - --- —
B07142-08 T02 COMMON -
1 BMC WEST (IDAHO FALLS), IDAHO FALLS, ID 83402
-1-0-0 _- i--- - — - - 4-&0
1-0-0 4-6-0
700112
3.4 M020
Qty - Piy - - -- — - - - ---
�2 Job Reference (optional)
7.030 s Jan 3 2008 MiTek Industries, Inc. Mon Jul 21 16:36:33 2008 Page 1
t-- - - - ---- -- 9-0- °- --- 10-0-0--1
4-6-0 1-0-0
sraw -1:ns
4.6 LOW =
c
1.5A M11201i
3M NOW=
- -4�-0 - --- - - --- -�- -- --- 9-0-0 - -- - - -- 1
_ 4-6-0 4-6-0
LOADING (psf) SPACING 2-0-0 CSI DEFL in (loc) Vdefl Ud PLATES GRIP
TCLL 35.0 Plates Increase 1.15 TC 0.29 Vert(LL) -0.01 B-F >999 360 M1120 1971144
Lumber Increase 1.15 BC 0.15 I Vert TL TCDL 7.0 I ( ) -0.02 B-F >999 240
BCLL 0.0 Rep Stress Incr YES WB 0.10 Horz(TL) 0.00 D n/a Na
BCDL� 7.0 - - -- Code IRC20061TP12002 -- I _ (Matrix) - Wind(LL) 0.00 F >999 240 _�- JWeight: 28 lb _ `-
LUMBER BRACING
TOP CHORD 2 X 4 SPF 165OF 1.5E TOP CHORD Structural wood sheathing directly applied or 640-0 oc pudins.
BOT CHORD 2 X 4 SPF 165OF 1.5E BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing.
WEBS 2 X 4 SPF Stud/Std
REACTIONS (lb/size) B=528/0-5-8, D=528/0-5-8
Max Horz B=-86(LC 3)
Max UpliftB=-157(LC 5). D=-157(LC 6)
FORCES (lb) - Maximum Compression/Maximum Tension
TOP CHORD A-B=0/45, B-C=478/71, C-D=478/70, D-E=0145
BOT CHORD B-F=0/317, D-F=0/317
WEBS C-F=0/179
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; h=25ft; TCDL=4.2psf; BCDL=4.2psf; Category 11; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) ' This truss has been designed for a live load of 20.0psf on the bottom chord in all areas where a rectangle 3-6-0 tail by 2-0-0 wide will fit between the bottom chord and any other members.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 157 lb uplift at joint B and 157 lb uplift at joint D.
6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
Job _1Truss____ Truss Type Qty Ply
B07142-08 T03 iCOMMON 7 - 1
Job Reference_ o honal
BMC WEST (IDAHO FALLS). IDAHO FALLS, ID 83402 _ 7.030 s Jan 3 2 00 8 T k Industries, Inc. Mon ,Jul 21 16:36:34 2008 Page 1
-1-0-0 6-6-0 13-0-0
I- - 1 — -- - -- — - — I -- - .. - - - - - -- -- — - 19-6"0 - — - i - -- —26-0-0 -- --- - 27-0-0
1-0-0 6-6-0 6-6-0 6-6-0 6-&0 1-0-0
scab - 1:41,0
5A M1120-
D 1T
-T.
TOM 12
5.6 NOW
/- W1
W1
W2
W2 ..,
s -
r
I
C 1 - _
__ -___-- __•-- __ _ -u.- -- -
o is
_
I J
K M
I.._-J'�-
5-6 M1120
54 M1120 =
W MI120 =
S.fi Mi120=
i 8-8-0 - — — — — 17-4-0 26-0-0 _
8-8-0 8-8-0 8-8-0
_ Plate Offsets (X,Y): [6:0-1-3.Edge]_[C:0-3-0,0-3-4], [E:0-3-0,0-3.4]. [F:0-1-3.Edge], [H:04-0,0-3-01, I.CL-0O73-0)-- _ -- -~ -- -- �- — — — -- - — -- — -
LOADING (psf) SPACING 2-0-0 I CSI DEFL in (loc) lldefl Ud PLATES GRIP
TCLL 35.0 j Plates Increase 1.15 I TC 0.53 Vert(LL) -0.31 H-1 >985 360 M1120 197/144
TCDL 7.0 1 Lumber Increase 1.15 BC 0,65 Vert(TL) -0.42 H-t >737 240
BCLL 0.0 Rep Stress Ina YES l WB 0.45 ' Horz(TL) 0.07 F nla nla
BCDL 7.0 Code IRC2006/TP12002 (Matrix) Wind(LL) 0.07 B-1 >999 240 Weight: 96lb
LUMBER BRACING
TOP CHORD 2 X 4 SPF 165OF 1.5E TOP CHORD Structural wood sheathing directly applied or 4-3-10 oc purlins.
BOT CHORD 2 X 4 SPF 1650F 1.5E BOT CHORD Rigid ceiling directly applied or 10-0-0 oc bracing,
WEBS 2 X 4 SPF Stud/Std
REACTIONS (lb/size) B=1445/0-5-8, F=144510-5.8
Max Horz B=-242(LC 3)
Max UpliRB=-329(LC 5), F=-329(LC 6)
FORCES (lb) - Maximum CompresslorUMaximum Tension
TOP CHORD A-B=0/45, B-C=-2179/406, C-D=-1910/435, D-E=-1910/435, E-F=-21791406, F-G=0/45
BOT CHORD B-1=-343/1754,1-J=-116/1181, J-K=-116/1181, H-K=-116/1181, F-H=-23411754
WEBS C-1=476/266, D-1=-184/744, D-H=-1841744, E-H=476/266
NOTES
1) Unbalanced roof live loads have been considered for this design.
2) Wind: ASCE 7-05; 90mph; h=25ft; TCDL=4.2psf; BCDL=4.2psf; Category II; Exp C; enclosed; MWFRS (low-rise) gable end zone; cantilever left and right exposed ; Lumber DOL=1.33 plate grip DOL=1.33.
3) This truss has been designed for a 10.0 psf bottom chord live load nonconcurrent with any other live loads.
4) • This truss has been designed for a live load of 20.Opsf on the bottom chord in all areas where a rectangle 3-6-0 tall by 2-0-0 wide will fit between the bottom chord and any other members.
5) Provide mechanical connection (by others) of truss to bearing plate capable of withstanding 3291b uplift at joint B and 329 lb uplift at joint F.
6) This truss is designed in accordance with the 2006 International Residential Code sections R502.11.1 and R802.10.2 and referenced standard ANSI/TPI 1.
LOAD CASE(S) Standard
i