HomeMy WebLinkAboutLOAD SHORT FORM 2 - 08-00440 - Boice Building #2 - New Building1%w Load Short Form Job: Boise Date: Sep 07, 2006 Complex 2 By: Palmer Heating & Cooli... B & S Boiler, Inc. _ FoProject Inf.v r: Boice Building #2 Rexburg, ID Htg Clg 08 00439 & 08 00440 Boice Bldg 42 1087 Summers Dr Outside db (OF) -6 89 Method Inside db (OF) 70 75 Construction quality Design TD (OF) 76 14 Fireplaces Daily range H Inside humidity (%) 50 50 Moisture difference (gr/lb) 62 -31 HEATING EQUIPMENT Make n/a Trade n/a Model n/a GAMA ID n/a Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat n/a 0 Btuh 0 OF 0 cfm 0.000 cfm/Btuh 0.00 in H2O n/a Infiltration Simplified Average 0 COOLING EQUIPMENT Make n/a Trade n/a Cond n/a Coil n/a ARI ref no. n/a Efficiency n/a Sensible cooling 0 Btuh Latent cooling 0 Btuh Total cooling 0 Btuh Actual air flow 0 cfm Air flow factor 0.000 cfm/Btuh Static pressure 0.00 in H2O Load sensible heat ratio 0.00 ROOM NAME Area (ft2) Htg load (Btuh) Clg load (Btuh) Htg AVF (cfm) Clg AVF (cfm) Basement 632 5125 117 157 7 B Stairs 2 87 0 0 0 0 Mechanical 68 0 0 0 0 Office 12 152 5068 2617 155 167 Office 2 2 133 2165 1350 66 86 Break Room 2 160 2496 2442 76 156 Storage 12 45 0 0 0 0 Stairs 2 78 0 0 0 0 Restroom 2 80 221 118 7 8 Storage 2 2 43 0 0 0 0 Conference 2 240 4907 3157 150 202 Office 3 2 213 6763 207 170 AAA] r, ,� 1fJ StP - b 2008 U1 Printout certified by ACCA to meet all requireme is of anual J 8th Ed. �• wrrght5oft- Rigtt-SuileTM universal 7.0.09 RSU02319 7y, 2008 Sep-0809:11:10 ACM C\Documentsertl Senings`tltrijotnNAy Dommenm\PHClWrightsofilProjectslB&SIB&S_Boicesu �0 �1 6 Ps 9)(rb-f jnn Page .w Complex2 p 2372 33033 15212 1010 973 Other equip loads 0 0 Equip. @ 0.94 RSM 14299 Latent cooling 164 Tl1TAI t` 77 �n 77n77 AAACA A/A/ IYs7 v lbw c��c �s�sv�� I�r�n.rr wiv ois Printout certified by ACCA to meet all requirements of Manual J 8th Ed. 19— H-F wrightooft- INgll.Suite'" Universal 7.0.09 RSU02319 2008-Sep0809:11:10 Zt*� C?Documents and SetlingsIchrijolnNy DommemsrPHC\WrightsoflrProjectsrB& SS 8S Boice.mp Cal Page Building Analysis n"�`_ Complex 2 " """ B & S Boiler. Inc. For: Boice Building #2 Rexburg, ID 'IMP, Job: Boica Date: Sep 07, 2008 By: Palmer Heating & Cool!... Location: Indoor: Heating Cooling Idaho Falls, ID, US Indoor temperature (OF) 70 75 Elevation: 4741 ft Design TD (OF) 76 14 Latitude: 44ON Relative humidity (%) 50 50 Outdoor: Heating Cooling Moisture difference(gr/lb) 61.5 -31.5 Dry bulb (OF) -0 89 Infiltration: Daily range F) - 34 (H) Method Simplified Wet bulb (F - 60 Construction quality Average Wind speed (mph) 15.0 7.5 Fireplaces 0 Component Btuh/ft2 Btu %of load Walls 5.0 8515 25.8 Glazing 26.6 6105 18.5 Doors 22.0 463 1.4 Ceilings 2.0 3133 9.5 Floors 2.2 3527 10.7 Infiltration 4.3 6307 19.1 Ducts 4983 15.1 Piping 0 0.0 Humidification 0 0.0 Ventilation 0 0.0 Adjustments -0 Total 33033 100.0 Component Btuh/ft2 Btu %of load Walls 0.3 560 3.7 Glazing 31.9 7320 48.1 Doors 5.4 113 0.7 Ceilings 1.1 1731 11.4 Floors 0.3 430 2.8 Infiltration 0.4 622 4.1 Ducts 1856 12.2 Ventilation 0 0.0 Intemal gains 2580 17.0 Blower 0 0.0 Adjustments -0 Total 1 16212 100.0 Overall U-value = 0.056 Btuh/ft'--°F Data entries checked. '- +41- wrightaort- Rigtd-SuiteTM universal 7.0.09 RSU02319 2008-Sep-0809:11:10 AM C.Occurnents and SeftmgMchrijolnNy Dowments\PHC\Wnghtsoft\Projec1s6&S\B&S_Boice.rup Cal Paget Component Constructions Job: Boice p Date: Sep 07, 2008 Complex 2 8y: Palmer Heating BCooli... B & S Boiler, Inc. Project• • For: Boice Building #2 Rexburg, ID Location: Idaho Falls, ID, US Elevation: 4741 ft Latitude: 44°N Outdoor: Heating Cooling Dry bulb (°F) -6 89 Daily range (OF) - 34 ( H) Wet bulb (°F) - 60 Wind speed (mph) 15.0 7.5 Indoor: Heating Indoor temperature (°F) 70 Design TD (°F) 76 Relative humidity (%) 50 Moisture difference(gr/lb) 61.5 Infiltration: Method Simplified Construction quality Average Fireplaces 0 Cooling 75 14 50 -31.5 Construction descriptions Or Area U-value InsulR HtgHTM Loss CIgHTM Gain a' ftw.'F W-'F/Btuh ftW Bluh Btu", Bluh Walls 12F-Osw: Fim wall, vnl ext, 1/2" wood Stith, r-21 cav ins, 1/2" n 292 0.065 21.0 4.94 1440 0.47 138 gypsum board int fnsh, 2"x6" wood frm a 40 0.065 21.0 4.94 198 0.47 19 s 340 0.065 21.0 4.94 1680 0.47 161 w 395 0.065 21.0 4.94 1951 0.47 187 all 1067 0.065 21.0 4.94 5269 0.47 506 15B11-Owc-6: Bg wall, light dry soil, 2"x4" wood int frm, concrete n 148 0.056 11.0 5.07 751 0.08 12 wall, r-11 cav ins, 8" thk, 1/2" gypsum board int fnsh s 148 0.056 11.0 5.07 751 0.08 12 w 344 0.056 11.0 5.07 1745 0.08 29 all 640 0.056 11.0 5.07 3247 0.08 54 Partitions (none) Windows 61C: Vinyl Frame, Double Pane, Low-E, .35 U-value, .34 SHGC; n 110 0.350 0.0 26.6 2913 11.4 1243 NFRC rated (SHGC=0.34) s 45 0.350 0.0 26.6 1197 20.2 909 w 75 0.350 0.0 26.6 1995 36.7 2754 all 230 0.350 0.0 26.6 6105 21.4 4906 Doors 11 PO: Door, mtl pur core type n 21 0.290 10.5 22.0 463 5.36 113 Ceilings 16B-38ad: Attic ceiling, asphalt shingles roof mat, r-38 ce it ins, 1/2" 1586 0.026 38.0 1.98 3133 1.09 1731 gypsum board int fnsh Floors 19A-19cvcp: Fir floor, frm fir, 12" thkns, carpet flr fnsh, r-19 oav ins, 799 0.049 19.0 2.92 2332 0.54 430 leaky crwl ovr 21A-32c: Bg floor, light dry soil, carpet flr fnsh 787 0.020 0.0 1.52 1195 0.00 0 ^, -Pk wrrghtsoflt- Pight-SureTM Universal T0.09 RSU02319 2008-Sep-0809:11.10 �IccA C:'llocumems and Seningsrhriiolnwly Documents\PHC\Wdghtsoft ProjeclslB&S a5 Soice.rup Cal Paget '� Job: Boice nae Project Summary Date: Sep 07, 2008 AH 2 By: Palmer Heating & Cooli... B & S Boiler, Inc. Prouect Information For: Boice Building #2 Rexburg, ID Notes: Front of home faces north Weather: Idaho Falls, ID, US Winter Design Conditions Outside db -6 OF Inside db 70 OF Design TO 76 OF Heating Summary Structure 28050 Btuh Ducts 4983 Btuh Central vent (72 cfm) 5049 Btuh Humidification 0 Btuh Piping 0 Btuh Equipment load 38083 Btuh Infiltration Method Simplified Construction quality Average Fireplaces 0 Area (f?) He23n72 in Co 2372 Volume (f?) 19243 19243 Air changes/hour 0.28 0.15 Equiv. AVF (cfm) 90 48 Heating Equipment Summary Make Lennox Trade Elite 90 Model G51MP-36B-070-** GAMA ID 113219 Efficiency Heating Input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 92.1 AFUE 66000 Btuh 55800 Btuh 1010 OF Cirri 0.031 cfm/Btuh 0.80 in H2O Summer Design Conditions Outside db 89 OF Inside db 75 OF Design TD 14 OF Daily range H Relative humidity 50 % Moisture difference -31 gr/Ib Sensible Cooling Equipment Load Sizing Structure 11879 Btuh Ducts 1650 Btuh Central vent (72 cfm) 930 Btuh Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.94 Equipment sensible load 13592 Btuh Latent Cooling Equipment Load Sizing Structure 335 Btuh Ducts -170 Btuh Central vent (72 cfm) Equipment latent load -1293 0 Btuh Btuh Equipment total load Req. total capacity at 1.00 SHR 13592 1.1 Btuh ton Cooling Equipment Summary Make Lennox Trade 13ACD Series Cond 13ACD-024-230* Coil C33-30+TDR+TXV ARI ref no. 1347297 Efficiency Sensible cooling Latent cooling Total cooling Actual airflow Air flow factor Static pressure Load sensible heat ratio Printout certified by ACCA to meet all requirements of Manual J 8th Ed. 13 SEER 23400 Btuh 0 Btuh 23400 Btuh 865 cfm 0.064 cfm/Btuh 0.80 in H2O 1.00 wrightmoft- Rig"-SolteTMUniversa17.0.09RSU02319 2009-Sep-0809:14:13 ACK C.Umumnis and SeeingsldrrijotnNy DommentsfHCUrightsoMprojectse&Se&S eoice.rup Cal Page Main floor \12 x 4 1 12 �12x4 12z4 166 cf s°"o.lsa.y.12 15 cfm 12x4 °p I12x4 167 fm 93 fm creek Roan 1 \ &ask Repm z 86 fm 167 cfm oma. r 1 oMp.21 ] omp.2 z Office 12 Bx14 8x14 8 x 14 166 fm 156 fm 167 fm 167 c 167 cfm Stevs1 Stsrs2 Stora9e21 14x8 14z8 86 cfm st.reo.zz 93 cfm ResUppml Resbpom2 95 cfm 199 fm 4x 12 101 cfm Con1B1°"C°' x 12 4 x 12 CW ..2 %189 Recepwn i 8 fm 8 fm Reseplion 2 4z12 x24 8x24 95 fm Cfm 202 fmx6 4x 12 7 cfm 101 Clint 24z6 207 fm 12x4 12x4 12x4 12x4 4x12 omp.ar �96fm fm 96 fm orc��zz 8 103fm 96fm ,Z,96 WL 12x4 4x12 12x4 /103fm /103cfm 103 Cfm Job #: Boice B & S Boiler, Inc. Performed by Palmer Heating & Coolin... Boice Building #2 1555 W Sunnyside Idaho Falls, ID 83402 Rexburg, ID Phone: (208) 524-1737 Fax: (208) 524-0801 bsboiler@srv.net Scale: 1 : 143 Page 1 Right-SuiW- Universal 7.0.09 RSU02319 2008-Sep-08 09:19:52 iments and Seftings\chrijohn\... Job#: Boice Performed by Palmer Heating & Coolin... Boioe Building #2 Rexburg, ID Basement B & S Boiler, Inc. 1555 W Sunnyside Idaho Falls, ID 83402 Phone: (208) 524-1737 Fax: (208) 524-0801 bsboiler@srv.net Scale: 1 : 143 Page 2 Right -Suite- Universal 7.0.09 RSU02319 2008-Sep-08 09:19:53 iments and Settings\chi Duct System Summary Job: Boice Date: Sep 07, 2008 AH 2 By: Palmer Heating & Cooli... ^EM. B & S Boiler, Inc. Project Information For: Boice Building #2 Rexburg, ID External static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.80 in H2O 0.39 in H2O 0.41 in H2O 0.23/0.18 in H2O 0.070 in/100ft 1010 cfm 585 ft Cooling 0.80 in H2O 0.40 in H2O 0.40 in H2O 0.23/0.17 in H2O 0.068 in/100ft 865 cfm Name Design (Btuh) Htg (Cfm) Clg (cfm) Design FIR Diam (in) H x W (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk Basement h 2563 78 4 0.111 6.0 OXO VIFx 36.5 175.0 st3 Reception h 3144 96 88 0.083 7.0 OXO VIFx 40.5 240.0 st3 Office 32 h 3381 103 85 0.081 7.0 OXO VIFx 43.4 245.0 st3 Reception 2A h 3144 96 88 0.070 7.0 Ox0 VIFx 33.5 300.0 st3A Off ice 32-A h 3381 103 85 0.105 7.0 Ox0 VIFx 48.5 175.0 st3 Conference 2-A c 1578 75 101 0.101 7.0 Ox0 VIFx 42.0 185.0 st3 Basement2-A h 2563 78 4 0.098 6.0 Ox0 VIFx 49.0 190.0 st4B Break Room 2 c 2442 76 156 0.095 8.0 Ox 0 VIFx 46.5 195.0 st4A Office 22 c 1350 66 86 0.105 6.0 OxO VIFx 42.0 175.0 st4A Office 12 C 2617 155 167 0.105 8.0 Ox0 VIFx 51.5 165.0 st4 Conference2 C 1578 75 101 0.107 7.0 OXO VIFx 38.0 175.0 st4 Restroom2 C 118 7 8 1 0.136 6.0 OXO I VIFx 1 7.7 160.0 st1 Name Trunk Type Htg (cfm) Clg (Cfm) Design FIR Veloc (fpm) Diam (in) H x W (in) Duct Material Trunk st1 Peak AVF 1010 973 0.070 758 14.8 8 x 24 ShtMetl st4A Peak AVF 221 246 0.095 554 8.2 8 x 8 ShtMetl st4 st4B Peak AVF 78 4 0.098 235 5.3 8 x 6 ShtMetl st4A st3 Peak AVF 552 451 0.070 710 11.8 8 x 14 ShtMetl st1 st3A Peak AVF 96 88 0.070 288 6.2 8 x 6 ShtMetl st3 st4 Peak AVF 451 514 0.095 772 10.9 8 x 12 ShtMetl I st1 -Hd-wrtghtsoft- Rjgft-SuileTM Universal Z0.09 RSU02319 2008-Sep-080914:13 CDocuments and Seaings'&rijairMy Documents\PHC\WrightsoflWrojecls\&SG&S_Boicemp Cal Pagel Name Grill Size (in) Htg (cfm) CIg (cfm) TEL (ft) Design FIR Veloc (fpm) Diam (in) H x W (in) Stud/Joist Opening (in) Duct Mall Trunk rb14 Ox0 157 7 123.5 0.143 586 7.0 Ox 0 ShMt rt3 rb5 Ox0 76 156 251.0 0.068 584 7.0 Ox 0 ShMt rt3B rb13 Ox0 66 86 152.0 0.113 440 6.0 Ox 0 ShMt rt3A rb12 Ox0 155 167 223.0 0.077 626 7.0 Ox 0 ShMt rt3A rb3 Ox0 199 183 115.0 0.153 570 8.0 Ox 0 ShMt rt3 rb11 Ox0 150 202 108.5 0.1581 578 8.0 Ox 0 ShMt rt4 rb10 Ox0 207 170 133.0 0.1321 592 8.0 Ox 0 ShMt rt4A Name Trunk Type Htg (Ciro) CIg (ctrn) Design FR Veloc (fpm) Diam (in) H x W (in) Duct Material Trunk rt3 Peak AVF 653 601 0.070 653 12.6 8 x 18 ShtMetl rt1 rt3A Peak AVF 297 410 0.068 615 10.6 8 x 12 ShtMetl rt3 rt3B Peak AVF 76 156 0.068 468 7.4 8 x 6 ShtMetl rt3A rt4A Peak AVF 207 170 0.132 620 7.2 8 x 6 ShtMetl rt4 rt4 Peak AVF 357 372 0.129 670 9.0 8 x 10 ShtMetl rt1 rt1 Peak AVF 1010 973 0.070 533 14.8 6-14x3.25 SdJstSp -H-F wHghtSof - Rigll-Suite^" Lkw.rsa17.0.09 RSU02319 2008-Sep0809:14:13 /4CCK C?Documents aM SeftingshitrijolyiNy Domments\PHC\Wnghlsoft\PmjectS0&Se&S Boice.mp Cal Page