RESIDENTIAL PLAN CHECKLIST
(2003 International Residential Code)
Building Permit Number:
Pr0j'eCt*-&ck,,9eI l tico-- Job Address:
��.
honing: 46ilo2
Number of Stories,Basement: e �To /Firs.Unfl-.
(Partial: s#)
(Note u�rafinished basements as special con on permit)
Floor Area (so: lj,3 fnzshed, �,� �junfinished, _garage
The following comments based on the 2003 edition of the Intem'ational Residential Code should be resolved
before a buumnor perrms t iissued. This correction lis is not a building permit. The approval of plans and
speca.fcations does not permit the violation of any section of the Intema tional Re s-idenrfial Code or any federal,
state or local regulations.
PLAN CHECK
A.Tans
i�
T o Scale legible
Plot Plan Y /CNFlood Plain
"'9
V Floor
Plan
+�
Section showing construction details
AIS Building Elevations
"1)esign Criteria (shall he identified onplans as Wind � S5Snow_m:p.h.; � S lb. Per sq ft.)
� Trr.-ISS Calcujatx4C)n Sheets & Floor Joist Dctai.ls
-Mechanical Design & Heat Load calc's
�nergy Calculations (8320 & Ch 11)
B. Zoning (circle one)
LDRI 12,1000,sf min. (width 80 ft..Min)
LD 8,000 sf min. (width 60 ft. min); Duplex 10,000 sq. ft. min. wit
RR2 21.,780 sf min. (width 150 ft min) Duplex allowed with C.U.P.
Other (Verify zoning requirements)
1.
h C.U.P.
c. use
_L/single
Family Duplex(Check zoning requirements for approval)
D. Set Backs (taken from eaves)
v''Frc�r�t set back �3� ft. from curb} I�Tvf�e: 6�% �.�n of front yard green
Xear set back (LDRI 25 ft. & LDR2 20 ft.)
Sides set backs 0" for every ft. of building height with LDR - 7.5' min., & LDRI - 6' min.)
�iluilding-Height (maximum'
30 ft.)
E. Footings
..,,43roper Size (as per Fable 40
.1, use 1500
psf unless sox �Te is known, Table 401.4.1 for soil bearing)
112ebarr (2-44 continuous)
Fooling Depth (3 6" below finished grade and 12" below undiswxbed sail; 1.8" to top of —interior)
F. Fundation
r✓ Foundation wads wI rebar (city ordinance)
A'
112" Anchor Bolts with �-'�--2-�=�-��f�" square washers (incl. inferior �earing k�Ta.11s)
,/F uzxdation Drainage (foundations on sift soil shall be designed. per R405)
Damp pro ofing/Waterpro ofincy to finish grade. R406.1 (fad. extends 6'" min above
"min. R408.3 (may dijr%.,P LI
f.
8403.1.6.1
grade'
8404.1.6)
Fer if meth appliance is in crawl space M 13 0 5.1.4)
-- -moi.-space Ventilation/ffisulation =1 sfveni per 150 sf.
k--,-
within 3' of each corner �insulate wads vent to inside of home) 8408.2
..................
Grading slops away from house. R401-3
with moisture barrier 1 sf.
G. frame
Seismic Hold Dawns and braced Wall Panels (-R602.10)
'Floors joists sized as per R502.3.,
r
Woad I joi.sts sized per manufr.
Joists Under Load Bearing Partitions shall be doubled. R:502A
�-�Beams sizedp er R502.,,
_7'
Cantilevers (comply wi
(refer to tables for enghieered products)
th
R502.33 or manufr instruction)
er 1500 sq. ft.) and
I
Floor Sheathing (3/4" min forjoists 24" oc & 5/8" forp"sts 16" oe) R503.2.2
V/Wall (bearing and nonbearing) stud sizes, height & spacing per Table 602:3(5) 8602.3
UIeadexs in Burin Wall sha�I tae designed a�per Tables 502.5(1&2) � 8602.7 _
Roof Trusses (desi reed according t� R802.10.1 35 # Snow
and 9Q mph winds (Local Conditions)
Rafter and Truss die -downs. (R802.10.5
Attic Access 22" x 30t$ min. roughopening (8$07)
H. Exterior Covering
J -,./—Masonry and stucco shall have weather resistive barrier over exterior shea
I, Roof Covering and Ventflation
s/]Raof Ventilation as per R.806
Asphalt Shingles' (slope>2:12) w/ ice protection. (Other type:
thing 8703.2 & 703.9.1
to comply w/ R905.--)
J. Firewalls
_zcGarage/House drywall separation (protect ext. walls & beams supporting habitable space) R309.2
Door from Garage to- House (13/8 sol"�d wood ox sieel daox, ar �0 min.. fire -rated dR309.1
� wo nilly Dwelling Separation (� hr fire separation) Supporting structure also rated 1017.1
,--�rhl4ttwies & Toi4)nhouses {2 hr separation & 4' overburn protection orparapet) R3.17.2
Wills paraflel to and within 3 ft of property line w/ NO openings allowed: 8302
--,Prnetrffj`i`ons- in previous 3 items is comply with R3173
r
K. eneral Requirements
Douse Numbers R3,21
Half Openable 3sf window or Mech. Ventilation in bathro,ms, water closets, and similar rooms. R3033
`Interior and exterior stair illumination shall comply tiNith R303.5.
,"�Bathroom Mxture clearances comply With Figure R3071
ane roam at least 120 sf.; ,s'Other habitable rooms 70 sf, min wl a min. dimension of 7 ft. R304
*areas w/ sloped ceilings less than 5 ft in height &fiirred ceilings less than 7ft DONOTcornpl y
*50� or more �f the �equiYed area mu,�t be a� least ?ft high in rooms vv/sloped ceiling
1 . //Egrecs c��axa�-�ce from v�rindow wells under cantilevered floors. R310.2
Gazing at Hazardous Locations R308
Emergency- Egress in all sleeping rooms and basements Nvith habitable space X310
One required Exit Door shall comply With 831 1.4
l
Lqndings at top and bottom of staxnN.-ays R311.5,4, and each side of each exterior door. R311.4.3
e IRur� 7 314" r�.a.a�. rise c� 14" min. dread, nosing �e�q'd if c1 �. "} ��a�.�r Width �3 G" m�n�,Stair Ris( �
iairway headroom (6' 8" min.} Handrea"
s (34"ta 3 8" above stair no. sing) (83 1 1. 5)
��a1 conditions for circular, spiral and winder stairways and bulkhead enclosures X311,5.8
,r
`'Stairway Protection (enclosed accessible space under stairs shall be covered with 1:2" drywall.) R311.2.2
�� �' �uardra�ls complying with 8312
Smoke Alamasx� e�oom, outside bedrooms, and on each level and per NEPA 72) (R 313)
L. Energy
c 15% of rocs area of ext. wallsjo)Aonhouses < 2� %} % comply ver Chapter 11Homes tenth glaz�x�.g g
�`Othenwise shall meet. rec�uiYements of IEC"�' far respbuilding type. see REScheck)
It
X-Capor retarder on warm in winter side of unventilated walls, ceiling and floors
�z *Water Heater heat traps IECC 504.7
✓lluct sealing and insulation N1103.3&4 or IECC 503.3.3.3, 503.3.3.4.3
L_.//Plans match -quantities & values on a "passim,' REScheck compliance report
M. Mechanical
i,�Gas appliances not in bedrooms, bathrooms, toilet rooms, or storage closets G240+6.2
QQm access 2.4'' min width/Attic access clear opening 20x.'OIUnder floor r.c�. 22x3O. M1305
Dryer Vent length 25' max wl 8' transition (-5' per 90 deg tams) M1501.3
Flue chase on plans? (B -vents require insulation shield through ins
uIated assemblies) G2426.4