LOAD SHORT FORM - 08-00437 - 1118 Coyote Willow Way - New SFR
zn .. PH. RF0R4t:1:�;:r Load Short Form Entire House Project Info For. Tallman Construction Job: Franklin plan Date: Sep 08, 2008 By: Performance Air Ilc 0800437 1118 Covote Willow Wav-Scholes Design Information Htg Cig Infiltration Outside db (°F) -6 89 Method Simplified Inside db (°F) 70 75 Construction quality SemHoose Design TD (°F) 76 14 Fireplaces 0 Daily range - H Inside humidity (°/a) 50 Moisture difference (gr/Ib) -31 HEATING EQUIPMENT Make Bryant Trade Bryant, Plus 90 Model 350MAV036060 Efficiency Heating input Heating output Temperature rise Actual air flow Air flow factor Static pressure Space thermostat 93.1 AFUE 60000 Btuh 56000 Btuh 71 OF 850 cfm 0.013 cfm/Btuh 0.65 in H2O COOLING EQUIPMENT Make Bryant Trade Legacy RNC 13 Puron AC Cond 113ANA018-A Coil CNPV'241W*+TDR Efficiency 13 SEER Sensible cooling 12390 Btuh Latent cooling 5310 Btuh Total cooling 17700 Btuh Actual air flow 720 cfm Air flow factor 0.100 cfm/Btuh Static pressure 0.65 in H2O Load sensible heat ratio 1.00 ROOM NAME 3 Area (ft2) Htg load (Btuh) Cig load (Btuh) Htg AVF (cfm) Cig AVF (cfm) M Bath 178 2615 363 33 36 M Bedroom 264 1878 371 24 37 Family Room 295 1650 167 21 17 Kitchen / Dining 334 3281 347 41 35 Den 162 2324 226 29 23 1/4 bath 36 0 0 0 0 Entry 225 1420 138 18 14 Room8 290 4247 537 54 54 Laundry 226 1014 104 13 10 WIC 109 2036 209 26 21 F Bedroom 5 232 2918 129 37 13 F. bedroom 6 216 1531 61 19 6 Future Kitchen 488 4721 195 59 19 F Bath 72 1539 69 19 7 Utility 146 1255 48 16 5 F Theatre 331 4114 177 52 18 149 41 15 F Bedroom 264 327 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wright5oft RighbSuBe Rwidentia16.0.101RSR40767 200&Sep.0807:45:33 A5�k ftj.tt.np Cat= MJ8 Odentatim z W Page l PDF created with pdfFactory trial version www.pdfactory.com F Powder 39 289 636 1150 28 28 8 14 3 3 Common Bedroom 4 188 2753 435 35 43 wic 4 41 731 108 9 11 wic 3 41 1201 154 15 15 bedroom 3 165 1273 272 16 27 Bath 98 752 161 9 16 Bath 1 58 372 88 5 9 Utility Room 131 774 193 10 19 Medea Room 506 4392 879 55 88 49 Bedroom 2 Future Bonus Room 209 586 3178 10422 492 1079 40 131 108 Entire House 6215 67450 7206 850 720 Other equip loads 6691 1233 Equip. @ 0.94 RSM 7933 Latent cooling 0 TOTALS 1 6215 l 74141 ' 7933 ' 850 ' 720 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. A. wrights4ft Right -Suite Residential 6.0.101 RSR40767 AZ N Projectl.rtp Calc = MJ8 Orientation = W 2008-Sep-08 07:45:33 Page 2 PDF created with pdfFactory trial version www.12dffacto[y.com PGRrQRMAN�'F Building Analysis �. .... Entire House Project Information For. Tallman Construction Job: Franklin plan Date: Sep 08, 2008 By: Performance Air Ilc Location: Indoor: Indoor temperature (OF) Heating 70 Cooling 75 Idaho Falls, ID, US Elevation: 4741 ft DesicTDCF) Relattive humiddity (e/a ) 76 50 14 50 Latitude: 44ON Outdoor: Heating Cooling Moisture difference r/Ib (9 ) 61.5 -31.5 Dry, bulb (OF)o 6 Daily range ( F) - 89 34 (H) Infiltration: Method Simplified Wet bulb ( ) 60 Construction quality Semi -loose Wind speed (mph) 15.0 7.5 Fireplaces 0 Component Btuh/fts Btuh % of load Walls 5A 32325 43.6 Glazing 0.0 0 0.0 Doors 0.0 0 0.0 Ceilings 2.1 5251 7.1 Floors 2.3 5898 8.0 Infiltration 4.6 23976 32.3 Ducts 0 0.0 Piping, 0 0.0 Humidification 0 0.0 Ventilation 6691 9.0 Adjustments 0 Total 74141 100.0 Coolin Component Btuh/ft' Btuh % of load Walls 0.4 2316 27.4 Glazing 0.0 0 0.0 Doors 0.0 0 0.0 Ceilings 0.9 2376 28.2 Floors 0.1 152 1.8 Infiltration 0.5 23622 28.0 Ducts Ventilation 1233 14.6 Internal gains 0 0.0 Blower 0 0.0 Adjustments 0 Total 8439 100.0 overall U-value = 0.050 Btuh/ft'--°F WARNING: window to floor area ratio = 0.0% - less than 5%. .�`... wrtghrSC) t Right-Suge Re idenlial6.0.101 RSR40767 AQ(p,Pmjectl.np CWc=MJB CVienlatiw=W 2008-Sep-08 07:45:33 Page 1 PDF created With pdfFactory trial version www.adffactory.com rI:R ,'R Component Constructions Entire House For: Tallman Construction Job: Franklin plan Date: Sep 08, 2008 By: Performance Air Ilc Design Conditions Location: Indoor: Heating Cooling Idaho Falls, ID, US Indoor temperature (°F) 70 75 Elevation: 4741 ft Design TD (°F)) 76 14 Latitude: 44°N Relative humidlty (%) 50 50 Outdoor: Heating Cooling Moisture difference (grAb) 61.5 -31.5 Dry bulb (OF) -6 89 Infiltration: Daily rang�°F) - 34 (H) Method Simplified Wet bulb ) - 60 Construction quality Semi -loose Wind speed (mph) 15.0 7.5 Fireplaces 0 Construction descriptions Walls 12F-Osw: Wood stud frame, siding or stucco, no board Insulation, R-21 cavity insulation 15B11-Ovm4: Basement - 8" concrete, wood framing, interior finish, R-11 cavity, no board insulation, 4' Partitions (none) Windows (none) Doors (none) Ceilings 17A-28ad: Ceiling w1 exposed beams, dark shingles, R-27 - 29 insul., 1%" wood deck 16B-38ad: Ceiling under vented attic, no radiant barrier, dark shingles, R-3B insulation Floors 20P-30c: Carpeted now over open crawl/garage, R-30 blanket insulation 21A-200: Carpeted basement Floor, No insulation, 20' wide 19A-Obscp: Carpeted floor over tight basement, No wall insul. No insul Or Area U-value Insul R Htg HTM Loss CIS HTM Gain fe BWWBi'F WF/BWh alul," BWh si BWh n 981 0.065 21.0 4.94 4B46 0.47 465 no 32 0.065 21.0 4.94 157 0.47 15 e 1031 0.065 21.0 4.94 5091 0.47 489 se 32 0.065 21.0 4.94 157 0.47 15 s 981 0.065 21.0 4.94 4846 0.47 465 w 1076 0.065 21.0 4.94 5313 0.47 510 all 4132 0.065 21.0 4.94 20410 0.47 1960 n 423 0.062 11.0 6.27 2654 0.19 79 e 527 0.062 11.0 627 3303 0.19 98 s 423 0.062 11.0 6.27 2654 0.19 79 w 527 0.062 11.0 6.27 3303 0.19 98 all 1899 0.062 11.0 6.27 11915 0.19 355 586 0.032 28.0 2.43 1426 0.45 263 1936 0.026 38.0 1.98 3825 1.09 2114 309 0.035 30.0 2.66 821 0.07 22 2130 0.027 0.0 2.05 4370 0.00 0 84 0.295 0.0 8.42 707 1.55 130 A� wrlghtsoft Right-SVIle Residential 6.0.101 RSR40767 2008-Se"B 07:45:34 /Bc K Pl j al." Cal. = MJB 06.Matiiin = W Page l PDF created With pdfFactory trial version www.adffactorv.com vy[-IghtSc3&t: Right -Suite Residential 6.0.101 RSR40767 �► Projectl.rrp Calc = M.18 Orientation = w 2008-Sep-08 07:45:34 Page 2 PDF created with pdfFactory trial version www.r)dffactory.com rl•_rtrclnN, �f l- Project Summary Entire House Project Information For: Tallman Construction Notes: lot 15 Block 2 West Frontage Design Information Idaho Falls, ID, US Winter Design Conditions Outside db -6 OF Inside db 70 OF Design TD 76 OF Heating Summary Structure 67450 Btuh Ducts 0 Btuh Central vent (95 cfm) 6691 Btuh Humidification 0 Btuh Piping 0 Btuh Equipment load 74141 Btuh Infiltration Job: Franklin plan Date: Sep 08, 2008 By: Performance Air Ile Summer Design Conditions Outside db 89 OF Inside db 75 OF Design TD 14 OF Daily range H Relative humidity 50 % Moisture difference -31 gr/lb Sensible Cooling Equipment Load Sizing Structure 7206 Btuh Ducts 0 Btuh Central vent (95 cfm) 1233 Btuh Blower 0 Btuh Use manufacturer's data n Rate/swing multiplier 0.94 Equipment sensible load 7933 Btuh Method Simplified Latent Cooling Equipment Load Sizing Construction quality Semi -loose Fireplaces 0 Structure -3284 Btuh Ducts 0 Btuh Heating Cooling Central vent (95 cfm) -1713 Btuh Area (ft=) 6215 6215 Equipment latent load 0 Btuh Volume (fta) 47631 47631 Air changeslhour 0.43 0.23 Equipment total load 7933 Btuh Equiv. AVF (cfm) 341 183 Req. total capacity at 0.70 SHR 0.9 ton Heating Equipment Summary Cooling Equipment Summary Make Bryant Make Bryant Trade Brryyant, Plus 90 Trade Legacy RNC 13 Puron AC 113ANA018-A Model 35CMAV036060 Cond Coil CNPV*2417A**+TDR Efficiency 93.1 AFUE Efficiency 13 SEER Heating input 60000 Btuh Sensible cooling 12390 Btuh Heating output 56000 Btuh Latent cooling 5310 Btuh Temperature rise 71 OF Total cooling 17700 Btuh Actual air flow 850 cfm Actual air flow 720 cfm Air flow factor 0.013 cfm/Btuh Air flow factor 0.100 cfm/Btuh Static pressure 0.65 in H2O Static pressure 0.65 in H2O Space thermostat Load sensible heat ratio 1.00 Printout certified by ACCA to meet all requirements of Manual J 8th Ed. wnght5afC RighlSuile Residential 6.D.101 RSR40767 20D&Sep-0807:45:34 ACr�K Pmjacti.np Cale = MJ8 Orientation = W rage 1 PDF created with pdfFactory trial version www.pdffactorv.com �f Basement "9*-0" CEILINGS" BASEMENT FLOOR PLAN xxo I1r . r-¢r Job M Franklin plan Performed by Performance Air Ilc for: Tallman Construction Scale: 1 : 144 Page 1 Right -Suite Residential 6.0.101 RSR40767 2008-Sep-08 07:45:42 Projectl .rrp PDF created with pdfFactory trial version www.gdffacto[y.com Main Floor 119'-0" CEIUNGS" MAIN FLOOR PLAN Job #: Franklin plan Performed by Performance Air lie for: Tallman Construction Scale: 1 : 144 Page 2 Right Suite Residential 6.0.101 RSR40767 2008-Sep-08 07:45:43 Projectl.rrp PDF created with pdfFactory trial version www.gdffactory.com 2nd floor SV4 unmahs, k4 Wc4g. 4 din 43 4 ?1 MbeRdr0000Mm 3,1 J,27 0..N 4 B rUTL;K3 R"I VNililYlCII --- -------- My 4�R0- 2 M-I ;Fj L I OL il "it Pill rM—F Fuhre Bonus Room -9.6-0-C-f 68dm --------- d MadeaRoom ............... .. . . .............. . .... ... WOO at ----- --- --- M Bad 2 r,4, CW! .6 L ALI ----- -- Job M Franklin plan Performed by Performance Air llc for: Tallman Construction Scale: 1 : 144 Page 3 Right -Suite Residential 6.0.101 RSR40767 2008-Sep-08 07:45:43 Projecti.rrp PDF created with pdfFactory trial version www.gdffactory.com t'rDuct System Summary Entire House Project Information For: Tallman Construction Extemal static pressure Pressure losses Available static pressure Supply / return available pressure Lowest friction rate Actual air flow Total effective length (TEL) Heating 0.65 in H2O 0.34 in H2O 0.31 in H2O 0.28 / 0.03 in H2O 0.035 in/100ft 850 cfm •� wright5vft Right -Suite RwidenD216A.iD1 RSR40767 A5. k Projects np Oelc = MJ8 Orienta0on = W 885 ft Job: Franklin plan Date: Sep 08, 2008 By: Performance Air Ilc Cooling 0.65 in H2O 0.34 in H2O 0.31 in H2O 0.28 / 0.03 in H2O 0.035 in/100ft 720 cfm 2Do6-Sep-0607:45:34 Page 1 PDF created with pdfFactory trial version www.pdffactory.com on .. Supply Branch Detail Table Name Design (Btuh) Htg (cfm) Clg (cfm) Design FR Dian (in) Rect Size (in) Duct Matl Actual Ln (ft) Ftg.Egv Ln (ft) Trunk M Bath C 363 33 36 0.081 6 Ox0 ShMt 29.5 310.0 st17 M Bedroom c 371 24 37 0.126 6 OxO ShMt 13.5 205.0 SO Family Room h 1650 21 17 0.064 6 Ox0 ShMt 31.5 400.0 st11 Kitchen/Dining h 3281 41 35 0.041 6 Ox0 ShMt 36.5 630.0 st7 Den h 2324 29 23 0.038 6 OxO ShMt 45.5 680.0 sty 114bath C 0 0 0 0.065 0 Ox0 ShMt 26.5 400.0 st11 Entry h 1420 18 14 0.063 6 OXO ShMt 35.5 400.0 St11 RoomB c 537 54 54 0.093 6 Ox0 ShMt 26.5 270.0 SO Laundry In 1014 13 10 0.131 6 Ox0 ShMt 5.5 205.0 sit WIC h 2036 26 21 0.106 6 Ox0 ShMt 15.5 245.0 st17 F Bedroom 6 h 2918 37 13 0.101 6 OxO ShMt 29.0 245.0 st17 F. bedroom 6 h 1531 19 6 0.132 6 Ox 0 ShMt 13.0 195.0 st2 Future Kitchen h 4721 59 19 0.045 6 Ox0 ShMt 36.0 575.0 St9 IF Bath h 1539 19 7 0.082 6 OxO ShMt 17.5 320.0 st17 utuity h 1255 16 5 0.285 6 Ox0 ShMt 1.5 95.0 F Theatre h 4114 52 18 0.094 6 OxO ShMt 24.5 270.0 sit F Bedroom h 3273 41 15 0.040 6 OxO ShMt 42.0 640.0 st7 FPoeder h 636 8 3 0.035 6 Ox0 ShMt 31.5 755.0 st3 Common h 1150 14 3 0.052 6 OxO ShMt 22.5 510.0 SO Bedroom C 435 35 43 0.079 6 OxO ShMt 38.0 310.0 st12 We a 108 9 11 0.046 6 Ox0 ShMt 51.5 550.0 st8 We C 154 15 15 0.035 6 Ox0 ShMt 60.5 720.0 st3 bedroom 3 C 272 16 27 0.037 6 OxO ShMt 47.5 700.0 st4 Bath c 161 9 16 0.039 6 OxO ShMt 30.5 680.0 sty Bath1 C 88 5 9 0.102 6 Ox0 ShMt 26.0 245.0 st14 Utility Room C 193 10 19 0.138 6 OxO ShW 19.0 180.0 st16 Medea Room C 879 55 88 0.053 6 OxO ShMt 38.0 485.0 st10 Bedroom C 492 40 49 0.041 6 Ox0 ShMt 53.5 615.0 st6 Future Bonus Room -A h 5211 66 54 0.133 6 Ox0 ShMt 27.0 180.0 SHEI Future Bonus Room h 5211 66 54 0.090 6 Ox0 ShMt 30.0 275.0 St17A wrlghtsoft Right -Suite Residential 6.0.101 RSR40767 �p Prolectl.np Cat = MJS Orientation = w 2008-Sep-08 07:45:34 Page 2 PDF created with pdfFactory trial version www.pdffactory.com u Name Trunk Type Htg (ofm) Clg (cfm) Design FIR Veloc (fpm) Diam (in) Rect Duct Size (in) Duct Material Trunk st3 Peak AVF 23 18 0.035 104 4 8 x 4 ShtMeU st5 st5 Peak AVF 78 84 0.038 252 7 8 x 6 ShtMeU st7 st7 Peak AVF 201 183 0.040 451 9 8 x 8 ShtMeU st9 s19 Peak AVF 269 213 0.045 485 10 8 x 10 ShtMetl st11 St11 Peak AVF 378 334 0.052 486 11 8 x 14 ShtMetl st13 st13 Peak AVF 413 377 0.035 464 12 8 x 16 ShtMeU SO SO Peak AVF 523 458 0.093 672 11 8 x 14 ShtMeU st1 st1 Peak AVF 569 524 0.126 731 11 8 x 14 ShtMetl st2 Peak AVF 265 191 0.132 796 8 8 x 6 ShtMeU SO Peak AVF 180 131 0.081 541 8 8 x 6 ShtMeU st2 st12 Peak AVF 35 43 0.079 196 4 8 x 4 ShtMeU st13 st8 Peak AVF 9 11 0.046 48 3 8 x 4 ShtMeU St9 st4 Peak AVF 16 27 0.037 122 4 8 x 4 ShtMetl st5 st14 Peak AVF 5 9 0.102 0 2 8 x 0 ShtMetl st15 st16. Peak AVF 10 19 0.138 87 3 8 x 4 ShtMetl St1 st10 Peak AVF 55 88 0.053 395 6 8 x 4 ShtMeU st11 st6 Peak AVF 40 49 0.041 221 5 8 x 4 ShtMeU st7 st18 Peak AVF 66 54 0.133 296 5 8 x 4 ShtMeU st2 SO7A Peak AVF 66 54 0.090 296 5 8 x 4 ShtMeU st17 Name Grill Size (in) I Htg (cfm) Clg (cfm) TEL (ft) Design FIR Veloc (fpm) Diam (in) RectSize (in) Stud/Joist Opening (in) Duct Mat Trunk rb1 Ox0 850 720 98.5 1 0.035 609 16 Ox 0 1 ShMt rt1 Return Trunk Detail Table Name Trunk Type Htg (cfm) Clg (cfm) . Design FIR Veloc (fpm) Diam (in) Rect Duct Size (in) Duct Material Trunk rt1 Peak AVF 850 720 0.035 546 16 8 x 28 ShtMetl '- wrrghtsoft Right -Suite Residential 6.0.101 RSR40767 p Project1 rrP Calp = MA Orientation = w 2006-Sep-0B 07:46:34 Page 3 PDF created with pdfFactory trial version www.lpdffactory.com