HomeMy WebLinkAboutPLANS - 08-00578 - T-Mobile Cell Tower - Replacement:Mils
31.75' —
27' —
rem
Pole Section Data
Tower Reactions
No Ice
Shear: 18.3 kips
Moment: 1028.6 ft -kips
Weight: 14.1 kips
With Ice
Shear: 13.9 kips
Moment: 753.0 ft -kips
Weight: 22.8 kips
032 1/2 in [32.50 in] FLANGE OC
022 3/4 in [22.75 In] FLANGE I.D.
3116" [1.19 in] HOLES
In DIAMETER BOLT CIRCLE
TOP FLANGE DETAIL
54.50 in FLANGE OD (6)00'-2 5/8" [2.63 in] HOLES
54 1/2 in
I 1 ON A 48.5 in DIAMETER BOLT CIRCLE
o --2.25" thick FLANGE
038 in [38.00 in] FLANGE
Overlap
Top Jacking Nut
Distance to Top Jacking Nut
(See Table for Minimum
and Maximum Values)
Ajacking nut is placed near the top of each section which will
have another section placed on top. The distance from this nut to
the bottom of the next section must not exceed the value given in
the column labeled "Maximum Distance to Top Jacking Nut"
Pole Splice Detail
I REV I BY I DATE I DESCRIPTION I
Mello Inc. It is not to be
copied or traced In wtK
without our written
BASE FLANGE DETAIL
TITLE:
T -Mobile
NTP 41" X 80'
ORIG. DATE: 9/27/2010 DWG No: 133760I Rexburg Cfty/SLO1403
Madison Co., ID
DWG. FROG: v2.05 SHEET: 1 OF 4
Jtr z S MID
0_
J.. C L L- O
:C)AWCIPATIU&Y
211 W. Washinglon St.,
Sufte 2000
ouch Bend, IN 46601-1705
Bus: (574)286-3632
Fall: (574)288-5860
Design
Maximum
Minimum
Bottom
Top
Number
Wall
Design
Minimum
Maximum
Distance
Distance
Distance
Section Height
Height
Length
of
Bottom
Top OD
Thickness
Material Approximate
Overlap
Overlap
Overlap
to Top
to Top
to Tap
(ft)
(ft)
(ft)
Sides
OD (in)
(in)
(in)
Weight (Ib)
(in)
(in)
(in)
Jacking
Jacking
Jacking
Nut (in)
Nut (in)
Nut (in)
1 27
80
53
18
36.5417
25.9500
0.1875
A572-65 3650
57
4811116
6211/16
15
23 5116
95/16
2 0
31.75
31.75
18
41.3750
35.0300
0.2500
A572-65 5150
Tower Reactions
No Ice
Shear: 18.3 kips
Moment: 1028.6 ft -kips
Weight: 14.1 kips
With Ice
Shear: 13.9 kips
Moment: 753.0 ft -kips
Weight: 22.8 kips
032 1/2 in [32.50 in] FLANGE OC
022 3/4 in [22.75 In] FLANGE I.D.
3116" [1.19 in] HOLES
In DIAMETER BOLT CIRCLE
TOP FLANGE DETAIL
54.50 in FLANGE OD (6)00'-2 5/8" [2.63 in] HOLES
54 1/2 in
I 1 ON A 48.5 in DIAMETER BOLT CIRCLE
o --2.25" thick FLANGE
038 in [38.00 in] FLANGE
Overlap
Top Jacking Nut
Distance to Top Jacking Nut
(See Table for Minimum
and Maximum Values)
Ajacking nut is placed near the top of each section which will
have another section placed on top. The distance from this nut to
the bottom of the next section must not exceed the value given in
the column labeled "Maximum Distance to Top Jacking Nut"
Pole Splice Detail
I REV I BY I DATE I DESCRIPTION I
Mello Inc. It is not to be
copied or traced In wtK
without our written
BASE FLANGE DETAIL
TITLE:
T -Mobile
NTP 41" X 80'
ORIG. DATE: 9/27/2010 DWG No: 133760I Rexburg Cfty/SLO1403
Madison Co., ID
DWG. FROG: v2.05 SHEET: 1 OF 4
Jtr z S MID
0_
J.. C L L- O
:C)AWCIPATIU&Y
211 W. Washinglon St.,
Sufte 2000
ouch Bend, IN 46601-1705
Bus: (574)286-3632
Fall: (574)288-5860
Portholes
Elevation`(ft)
Qty
Size (in)
Azimuth (deg)
76
3
8 x 12
30, 165, 285
60
3
8 x 12
30, 165, 285
48
3
8x 12
30,165, 285
44
2
6 x 6
90,270
7
1
18 x 30
90
7
1
18 x 30
270
3
1
18 x 30
0
3
1
18x30
160
Antenna Loading
Height
Qty.
Description
100'
1
6' Lightning Rod
77'
12
TMBXX-6517-R2M
77'
3
T -Arms - 5' Standoff x 12' Face Width
64'
12
TMBXX-6517-R2M
64'
3
T -Arms - 5' Standoff x 12' Face Width
52'
12
TMBXX-6517-R2M
r7752'
3
T -Arms - 5' Standoff 12' Face Width
Dish Loading
HeightQty.
Qty.
Description
45'
1
4' Dish with Radome
REV I BY I DATE
Feedline Loading
Height
Qty.
Description
0'- 77'
24
LDF5-50A (7/8 FOAM)
0'- 64'
12
LDF5-50A (7/8 FOAM)
0' - 52'
12LDF5-50A
(7/8 FOAM)
0' - 45'
1
LDF5-50A (7/8 FOAM)
180'
t
Step Bolts on This
Side of Pole
Note:
The azimuths referenced here are only to illustrate where the pole
features are in relation to each other. The azimuths are not to indicate
which cardinal direction the anchor bolts or the pole should be positioned.
Pole Reference Azimuths
Pole Base Flange
0'
Anchor Bolt Holes
Are on Either Side of
the 0 Degree Azimuth
Anchor Bolt Azimuth
TITLE:
T -Mobile
NTP 41" X 80'
COPYRIGHT NOTICE: ORIG. DATE: 9/27/2010 DWG NO: 133760 Rexburg CRY/SL01403
This drawing is the property of
DESCRIPTION Nello Inc. It is not to be reproduced ,Madison Co., ID
copied or traced in whole or In part DWG. FROG: v2.05 SHEET: 2 OF 4
without our written consent.
SEP 2 8 20108 2010
V
211 W. Washington st;
Suite 2000
x4h Bend, IN 46601-1705
Bus:(574)268.3632
Fax: (574) 2885860
REV B�
PLAN VIEW
r2.25" dia. x 72" ASTM A615 grade 75 anchor bolts
( on a 48.50" bolt circle
P/N 108742.
6 total.
3 3/8"
Max.
i
�— Top of concrete
Embedment plate
P/N 133763.
Remove top plate before erecting pole.
ANCHOR BOLT DETAIL
SEP 28 2010
TITLE:bl
T -Mobile
NTP 41" X 80'
N e L L o
c: Fti cz a er cx ra•rr rave
211 W. Washington SI.,
COPYRIGHT NOTICE: ORIG. DATE: 9/27/2010 DWG NO: 133760
Rexburg City/81-01403
This drawing is the property of
Suite
DESCRIPTION Nello Inc. It is not to be reproduced,
Madison Co., ID
South
South Bend, IN 46601-1705
B: nd, IN 46601-1
copied or traced In whole or In part DWG. FROG: V2.05 SHEET: 3 OF q
-3632
Without our Wfiden congenA
Fax (57 412 8 6-5 660
Tower Notes:
1. Tower is designed per TIA-222-G, "Structural Standard for Antenna Supporting Structures and Antennas," for the following loading conditions:
100 mph 3 -second gust basic Wind speed with no ice
90 mph 3 -second gust basic wind speed with 112 inch basic ice thickness
Structure Class: II
Exposure Category: C
Topographic Category: 1
2. Tower design loading is assumed to be based on site-specific data and must be verified by others prior to installation.
3. Tower design includes the antennas, dishes, and/or lines listed in the appurtenance loading tables on sheet 2.
4. Antenna mounting pipes may need to be field cut to match the lengths listed in the appurtenance loading tables on sheet 2.
5. Tower member design does not include stresses due to erection since erection equipment and procedures are unknown. Tower installation shall be performed by competent and qualified erectors in
accordance with TIA-222-G and OSHA standards and all applicable building codes.
6. Field connections shall be bolted. No field welds shall be allowed unless otherwise noted.
7. Structural bolts shall conform to ASTM A325, except for 1/2 inch diameter and smaller bolts, which shall conform to ASTM A449 or SAE J429 Grade 5.
8. Structural steel and connection bolts shall be galvanized after fabrication in accordance with TIA-222-G.
9. All high strength bolts shall be tightened to a "snug tight" condition as defined in the November 13, 1985, AISC "Specification for Structural Joints Using ASTM A325 or A490 Bolts."
10. Tower shall be marked and lighted in conformance with local building codes, FAA regulations, and TIA-222-G.
11. Tower shall be grounded in conformance with local building codes and TIA-222-G.
12. Allowable tolerance on as -built tower steel height is plus 1% or minus 1l2%.
13. Maintenance and inspection shall be performed over the life of the structure in accordance with TIA-222-G.
14. Material specifications:
NTP 18 -Sided Pole - ASTM A572 Grade 65
Pole Flange - ASTM A572 Grade 50
Pole Porthole Rim - ASTM A572 Grade 65
15. Ajacking nut Is placed near the top of each section which will have another section placed on top. The distance from this top jacking nut to the bottom of the next section must not exceed the value given in
the column labeled "Maximum Distance to Top Jacking Nut" Jacking may be required to achieve the proper overlap.
16. The horizontal distance between the vertical centerlines at any two elevations shall not exceed 0.25 percent of the vertical distance between the two elevations. Measure early In the morning before the
sunward side of the pole expands.
17. Sections must be erected with the 0 degree azimuth lined up to ensure proper fit.
18. Remove anchor bolt template before erecting pole. Non -shrink grout maybe placed under base flange after leveling pole. Drain holes must be provided if grouting.
19. Concrete contractor shall be responsible for properly aligning anchor bolts and materials before and after placing concrete, regardless of whether an anchor bolt template is provided.
I REV I BY I DATE I DESCRIPTION I
This drawing Is the property of
Nato Inc. It is not to be reproduced,
copied or traced In whole or in part
without our written consent.
ORIG. DATE: 9/27/2010
DWG. FROG: v2.05
NO: 133760
SHEET: 4 OF 4
T -Mobile
NTP 41" X 80'
Rexburg City/SL01403
Madison Co., ID
SEP 2 8 2010
211 W. Washington St.,
Fax: