Loading...
HomeMy WebLinkAboutENGINEERING ADDENDUM - 08-00362 - 08-00362 - Springhill Suites Marriott Hotel.pdfi ACUTE ENGINEERING 1429 South State St. Orem, Utah 84097 Phone 801.229.9020 Fax 801.224.0050 info@a cuteengi neering.com P. C. Requested by: Company: Contact Number: Fax to: Prepared by: B0 Letter Number: L. a I - _a $p� � 5y'�gwezn ora lis Architect pcl) 3T 7 -_6j03 ( 0`t) -no'o Johnn Jud 2449 Engineering Addendum Project Name: Project Location: Project Number: Date: Ken Harris SpringHill Suites Rexburg Idaho (Ken Harris) 740608 1750 S Yellowstone Highway Rexburg, Idaho 83440 740608 10/5/2009 The following is in response to an email request by Todd Mitchell (RVC) on October 5, 2009, regarding the hold-down straps to the steel beam above the swimming pool area. The hold-down straps shall be bolted using (2) Y2 inch diameter bolts to the long leg of a L6x4x3/8 steel angle (installed with the long leg vertical) and the steel angle shall be bolted using (2) % inch diameter bolts (or welded) to the bottom ftange of the steel beam. This addendum is for the project and location listed. It may not be reused, copied or reproduced without written consent from Acute Engineering P.C. 40.17849i"\%-' ;ULROLLINS I T Ki Valid Wet Stamp In Red sm