Loading...
HomeMy WebLinkAboutBOLT INSPECTION - 19-00718 - 1137 Summers Dr - Valleywide Coop-Forsgren - Commercial Building Environmental Services  Geotechnical Engineering  Construction Materials Testing  Special Inspections 1230 N Skyline Drive, Suite C  Idaho Falls, ID 83402  (208) 529-8242  Fax (208) 529-6911 www.mti-id.com  mti@mti-id.com Revised May 2016 Steve Wilcox Phone: (208) 709-7553 Teton West of Idaho Fax: 162 North Yellowstone Highway (PO Box 176) Other: E-REPORTS ONLY Rigby, ID 83442 Project: North Point Holdings, 1165 Summers Drive, Rexburg, ID Permit #: Project Manager: Derrick Fontes MTI File #: E200047n INSPECTION/TESTING REPORT Our representative(s) performed work on the above referenced project. Attached you will find the corresponding inspection and/or test reports. Please refer to the attached reports for details and locations of our testing and inspection services. If there are questions concerning the attachment(s), please contact the project manager at (208) 529-8242. Respectfully submitted, MATERIALS TESTING & INSPECTION, LLC cc: Attachments: rpt001hsb Idaho | Montana | Nevada | Oregon | Utah | Washington | Wyoming mti@mti-id.com • www.mti-id.com Environmental Services Geotechnical Engineering Construction Materials Testing Special Inspections MATERIALS TESTING & INSPECTION HIGH STRENGTH BOLTING REPORT Rev. May 2016 Date: __________________ MTI File #:_________________________ Project Name: _____________________________________ Contractor: _______________________________________________ Permit #:__________________________________________ Inspector: ________________________________________________ Weather: _________________________________________ Project Specifications  Snug Tight only  Full Tension/Slip Critical  Turn-of-the-Nut method  Calibrated Wrench method  Direct Tension Indicators  Load-Indicating Washers  Twist-Off-Bolts (”Lejune” bolts) Bolt Type  ASTM A-325  ASTM A-490  Other (specify): __________________________ Bolt Size Diameter: ____________ Length: ______________ Diameter: ____________ Length: ______________ Diameter: ____________ Length: ______________ Washer Specifications  Hardened washers  Plate washers  None required General Conditions  Faying surfaces ush and in full contact  Faying surfaces free from paint, oil, etc.  Visually monitored turn-of-the-nut method  Veried installation equipment and bolts using Skidmore-Wilhelm tension measuring device  Applied Inspection torque of _____________ft/lbs to ______________ diameter bolts _____________ft/lbs to ______________ diameter bolts  Visually inspected twist-off bolts  Washers at slotted holes under turned element  Inspected load-indicating washers with feeler gauge to:  0.015”  0.005”  Other: ___________  Veried a minimum of 2 bolts per connection or 10% of all bolts  Other (specifiy): ________________________________ Location(s): Reference Drawing Sheet and Detail, and Approved RFI: ____________________________________________________________ Work Inspected was:  in compliance  except as noted  reinspection/retesting required Remarks: NOTICE: Our firm’s professionals are represented on site solely to observe operations of the contractor identified, to form opinions about the adequacy of those operations, and to report those opinions to our client. The presence and activities of our field representatives do not relieve any contractor from its obligation to meet contractual requirements. No one except our client may rely on our findings and opinions. The contractor retains sole responsibility for site safety and the methods, operations, and sequences of construction.  This Report is Preliminary. A preliminary report is provided solely as evidence that eld observation was performed. Observations and/or conclusions and/or recommendations conveyed in the nal report may vary from and shall take precedence over those indicated in a preliminary report.  This Report is Final. A nal report is an instrument of professional service. Any conclusions drawn from this report should be discussed with and evaluated by the professional involved. Inspector: _________________________________________ Date: ________________ Note: The recording of false, fictitious or fraudulent statements or entries on this document may be punishable as a felony under Federal Statute. Reviewed by: ______________________________________Date: ________________ Contractor Initials: ____________ 3/5/2020 E200047n North Point Holdings Teton West Josh Clark Sunny 4 4 4 4 3/4"Varied 4 4 4 Rigid frame. 4 3/5/2020 4 3/6/2020Alex Liang 3/6/2020 Page 1 of 1 rpt001hsb