Loading...
HomeMy WebLinkAboutLOAD SHORT FORM - 21-00154 - 2325 W 860 S - New SFRCalculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Mar-11 08:38:47 Right-Suite® Universal 2019 19.0.13 RSU20477 Page 1 ...Country\Wrightsoft\Eicap\SF13B7. princeton.rup Calc = MJ8 House faces: N SF13B7Job:Load Short Form Date:Entire House Vince ByramBy: High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryhtg@gmail.com Project Information Cody PuzeyFor: 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Design Information InfiltrationClgHtg SimplifiedMethod89-6Outside db (°F) AverageConstruction quality7570Inside db (°F) 0Fireplaces1476Design TD (°F) H-Daily range 5050Inside humidity (%) -3162Moisture difference (gr/lb) HEATING EQUIPMENT COOLING EQUIPMENT Make Goodman Mfg.Make Goodman Mfg. Trade GOODMAN Trade GOODMAN, JANITROL, AMANA DISTI... Model GMH950703BX Cond GSX130241C* AHRI ref 2002183 Coil Capf3030bx AHRI ref 4765510 Efficiency 95 AFUE Efficiency 11.0 EER, 13 SEER Heating input Btuh69000 Sensible cooling Btuh16100 Heating output Btuh52440 Latent cooling Btuh6900 Temperature rise °F62 Total cooling Btuh23000 Actual air flow cfm920 Actual air flow cfm767 Air flow factor cfm/Btuh0.028 Air flow factor cfm/Btuh0.079 Static pressure in H2O0.70 Static pressure in H2O0.70 Space thermostat Load sensible heat ratio 1.00 ROOM NAME Area Htg load Clg load Htg AVF Clg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) Room1 604 13506 2942 375 233 Room2 52 0 0 0 0 Room3 150 2249 306 62 24 Room4 250 3448 1634 96 129 Room5 242 2078 865 58 69 Room6 169 2843 895 79 71 Room7 50 589 96 16 8 Room8 154 2184 1324 61 105 Room9 132 2831 1364 79 108 Room10 35 632 52 18 4 Room11 82 2770 208 77 16 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Mar-11 08:38:47 Right-Suite® Universal 2019 19.0.13 RSU20477 Page 2 ...Country\Wrightsoft\Eicap\SF13B7. princeton.rup Calc = MJ8 House faces: N Entire House d 1920 33130 9685 920 767 Other equip loads 1821 335 Equip. @ 0.94 RSM 9419 Latent cooling 0 TOTALS 1920 34950 9419 920 767 2021-Mar-11 08:38:47 Right-Suite® Universal 2019 19.0.13 RSU20477 Page 1...Country\Wrightsoft\Eicap\SF13B7. princeton.rup Calc = MJ8 House faces: N SF13B7Job:Building Analysis Date:Entire House Vince ByramBy: High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryhtg@gmail.com Project Information Cody PuzeyFor:3758 Yellowstones Hwy, Idaho Falls, Id 83401Phone: 208-529-2116 Design Conditions Location:CoolingHeatingIndoor:7570Indoor temperature (°F)Idaho Falls, ID, US 1476Design TD (°F)ft4741Elevation:5050Relative humidity (%)°N44Latitude:Outdoor:-31.561.5Moisture difference (gr/lb)CoolingHeating Infiltration:89-6Dry bulb (°F)SimplifiedMethod)H(34-Daily range (°F) AverageConstruction quality60-Wet bulb (°F) 0Fireplaces7.515.0Wind speed (mph) Heating Walls Glazing Doors Ceilings Floors Infiltration Ventilation % of loadBtuhBtuh/ft²Component 31.8111194.9Walls 14.3499223.7Glazing 2.690022.0Doors 5.117771.5Ceilings 12.142283.63.6Floors 28.9101144.0Infiltration 00Ducts00Piping00Humidification5.21821Ventilation0Adjustments100.034950Total Cooling Walls Glazing Doors Ceilings Other InfiltrationVentilation % of loadBtuhBtuh/ft²Component 10.710680.5Walls 63.0631330.0Glazing 2.22195.4Doors 9.89820.8Ceilings 1.31340.1Floors 9.79690.4Infiltration 00Ducts3.3335Ventilation00Internal gains 00Blower0Adjustments100.010021Total Latent Cooling Load = 0 BtuhOverall U-value = 0.063 Btuh/ft²-°F Data entries checked. 2021-Mar-11 08:38:47Right-Suite® Universal 2019 19.0.13 RSU20477 Page 1...Country\Wrightsoft\Eicap\SF13B7. princeton.rup Calc = MJ8 House faces: N SF13B7Job:Component Constructions Date:Entire House Vince ByramBy: High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryhtg@gmail.com Project Information Cody PuzeyFor:3758 Yellowstones Hwy, Idaho Falls, Id 83401Phone: 208-529-2116 Design Conditions Location:CoolingHeatingIndoor: 7570Indoor temperature (°F)Idaho Falls, ID, US 1476Design TD (°F)ft4741Elevation: 5050Relative humidity (%)°N44Latitude:Outdoor:-31.561.5Moisture difference (gr/lb)CoolingHeating Infiltration:89-6Dry bulb (°F) SimplifiedMethod)H(34-Daily range (°F) AverageConstruction quality60-Wet bulb (°F) 0Fireplaces7.515.0Wind speed (mph) Construction descriptions GainLossClg HTMHtg HTMInsul RU-valueAreaOr BtuhBtuh/ft²BtuhBtuh/ft²ft²-°F/BtuhBtuh/ft²-°Fft² Walls 12F-0sw: Frm wall, vnl ext, 3/8" wood shth, r-21 cav ins, 1/2" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud 560.475784.9421.00.065117ne 380.474004.9421.00.06581nw 940.479784.9421.00.065198all Frm wall, vnl ext, 3/8" wood shth, r-22 cav ins, 1/2" gypsum board int fnsh, 2"x6" wood frm, 16" o.c. stud 2100.4721874.9422.00.065443ne 2780.4728904.9422.00.065585se 2470.4725754.9422.00.065521sw 2390.4724904.9422.00.065504nw 9740.47101414.9422.00.0652053all Partitions (none) Windows61C: 61C; 6.67 ft head ht 133123.6128422.800.30056ne 119623.9121624.300.32050ne 75330.157022.800.30025sw 240130.4192124.300.32079sw 568027.0499223.700.320210all Doors 11P0: Door, mtl pur core type 2195.3790022.010.50.29041sw Ceilings 16B-50ad: Attic ceiling, asphalt shingles roof mat, r-50 ceil ins, 5/8" gypsum board int fnsh 9820.8417771.5250.00.0201169 Floors19A-30bscp: Part floor, carpet flr fnsh, r-30 ins, frm flr, 12" thkns, 1/2" gypsum board int fnsh 1340.407292.1730.00.034336 21A-24t: Bg floor, heavy dry or light damp soil, 6' depth 00.025117 002221.90 22B-10cpm: Bg floor, heavy dry or light damp soil, on grade depth, r-10 edge ins, carpet flr fnsh 00318427.010.00.355118 009427.010.00.3553 00327727.010.00.355121all 2021-Mar-11 08:38:47Right-Suite® Universal 2019 19.0.13 RSU20477 Page 2...Country\Wrightsoft\Eicap\SF13B7. princeton.rup Calc = MJ8 House faces: N Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Mar-11 08:38:47Right-Suite® Universal 2019 19.0.13 RSU20477 Page 1...Country\Wrightsoft\Eicap\SF13B7. princeton.rup Calc = MJ8 House faces: N SF13B7Job:Project Summary Date:Entire House Vince ByramBy: High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryhtg@gmail.com Project Information Cody PuzeyFor:3758 Yellowstones Hwy, Idaho Falls, Id 83401Phone: 208-529-2116 Notes: Design Information Idaho Falls, ID, USWeather: Winter Design Conditions Summer Design Conditions Outside db °F-6 Outside db °F89Inside db °F70 Inside db °F75Design TD °F76 Design TD °F14Daily range HRelative humidity %50Moisture difference gr/lb-31 Heating Summary Sensible Cooling Equipment Load Sizing Structure Btuh33130 Structure Btuh9685DuctsBtuh0DuctsBtuh0Central vent (26 cfm)1821 Btuh Central vent (26 cfm)Btuh335Outside air Outside airHumidificationBtuh0Blower Btuh0PipingBtuh0Equipment load Btuh34950 Use manufacturer's data nRate/swing multiplier 0.94InfiltrationEquipment sensible load Btuh9419 Method Latent Cooling Equipment Load SizingSimplifiedConstruction quality Average0Fireplaces Structure Btuh-1347Ducts Btuh0Central vent (26 cfm)Btuh-466CoolingHeatingOutside air19201920Area (ft²)Equipment latent load Btuh01728017280Volume (ft³)Air changes/hour 0.260.50 Equipment Total Load (Sen+Lat)Btuh9419Equiv. AVF (cfm)75144 Req. total capacity at 0.70 SHR ton1.1 Heating Equipment Summary Cooling Equipment Summary Make Goodman Mfg.Make Goodman Mfg.Trade GOODMAN Trade GOODMAN, JANITROL, AMANA DISTI...Model GMH950703BX Cond GSX130241C*AHRI ref 2002183 Coil Capf3030bxAHRI ref 4765510Efficiency95 AFUE Efficiency 11.0 EER, 13 SEERHeating input Btuh69000 Sensible cooling Btuh16100Heating output Btuh52440 Latent cooling Btuh6900Temperature rise °F62 Total cooling Btuh23000Actual air flow cfm920 Actual air flow cfm767Air flow factor cfm/Btuh0.028 Air flow factor cfm/Btuh0.079Static pressure in H2O0.70 Static pressure in H2O0.70Space thermostat Load sensible heat ratio 1.00 2021-Mar-11 08:38:47 Right-Suite® Universal 2019 19.0.13 RSU20477 Page 1 ...Country\Wrightsoft\Eicap\SF13B7. princeton.rup Calc = MJ8 House faces: N SF13B7Job:AED Assessment Date:Entire House Vince ByramBy: High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryhtg@gmail.com Project Information Cody PuzeyFor: 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 Design Conditions Location:CoolingHeatingIndoor: 7570Indoor temperature (°F)Idaho Falls, ID, US 1476Design TD (°F)ft4741Elevation: 5050Relative humidity (%)°N44Latitude:Outdoor:-31.561.5Moisture difference (gr/lb)CoolingHeating Infiltration:89-6Dry bulb (°F))H(34-Daily range (°F) 60-Wet bulb (°F)7.515.0Wind speed (mph) Test for Adequate Exposure Diversity Hourly Glazing Load Hourly Average AED limit Gla z i n g l o a d ( B t u h ) Hour of Day 0 1,000 2,000 3,000 4,000 5,000 6,000 7,000 8,000 8 9 10 11 12 13 14 15 16 17 18 19 20 Maximum hourly glazing load exceeds average by 42.3%. House does not have adequate exposure diversity (AED), based on AED limit of 30%. AED excursion: 633 Btuh (PFG - 1.3*AFG) Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Mar-11 08:38:47Right-Suite® Universal 2019 19.0.13 RSU20477 Page 1...Country\Wrightsoft\Eicap\SF13B7. princeton.rup Calc = MJ8 House faces: N SF13B7Job:Right-J® Worksheet Date:Entire House Vince ByramBy:High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryhtg@gmail.com 1 Room name Entire House Room1 2 Exposed wall 278.0 ft 101.0 ft3Room height 9.0 dft 9.0 heat/coolft 4 Room dimensions ft604.0x1.0 5 Room area 1920.0 ft²604.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12F-0sw12F-0sw 0.0650.065 nene 4.944.94 0.470.47 117 117 578 56 0 0 0 0.WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nene 4.944.94 0.470.47 549 443 2187 210 216 160 789 76.GG 61C61C 0.3000.300 nene 22.8022.80 23.6323.63 56 0 1284 1331 56 0 1284 1331 .GG 61C61C 0.3200.320 nene 24.3224.32 23.9123.91 50 0 1216 1196 0 0 0 0 11 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 sese 4.944.94 0.470.47 585 585 2890 278 297 297 1467 141 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 swsw 4.944.94 0.470.47 666 521 2575 247 216 150 742 71 GG 61C61C 0.3000.300 swsw 22.8022.80 30.1130.11 25 0 570 753 25 0 570 753GG61C61C0.3200.320 swsw 24.3224.32 30.3930.39 79 0 1921 2401 0 0 0 0 DD 11P011P0 0.2900.290 swsw 22.0422.04 5.365.36 41 41 900 219 41 41 900 219WW12F-0sw12F-0sw 0.0650.065 nwnw 4.944.94 0.470.47 81 81 400 38 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nwnw 4.944.94 0.470.47 504 504 2490 239 180 180 889 85CC16B-50ad16B-50ad 0.0200.020 --1.521.52 0.840.84 1169 1169 1777 982 22 22 33 18FF19A-30bscp19A-30bscp 0.0340.034 --2.172.17 0.400.40 336 336 729 134 0 0 0 0 FF 21A-24t21A-24t 0.0250.025 --1.901.90 0.000.00 117 117 222 0 0 0 0 0FF22B-10cpm22B-10cpm 0.3550.355 --26.9826.98 0.000.00 656 118 3184 0 604 101 2725 0 FF 22B-10cpm22B-10cpm 0.3550.355 --26.9826.98 0.000.00 60 3 94 0 0 0 0 0 6 c) AED excursion 633 -135 Envelope loss/gain 23016 8716 9400 2560 12 a)Infiltration 10114 969 3675 352 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)33130 9685 13074 2912 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0RedistributionRedistribution004313014Subtotal331309685135062942 15 Duct loads 0%0%0 0 -0%0%0 0 Total room load 33130 9685 13506 2942 Air required (cfm)Air required (cfm)920 767 375 233 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Mar-11 08:38:47Right-Suite® Universal 2019 19.0.13 RSU20477 Page 2...Country\Wrightsoft\Eicap\SF13B7. princeton.rup Calc = MJ8 House faces: N SF13B7Job:Right-J® Worksheet Date:Entire House Vince ByramBy:High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryhtg@gmail.com 1 Room name Room2 Room3 2 Exposed wall 17.0 ft 25.0 ft3Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft4.0x13.0 ft15.0x10.0 5 Room area 52.0 ft²150.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12F-0sw12F-0sw 0.0650.065 nene 4.944.94 0.470.47 0 0 0 0 0 0 0 0.WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nene 4.944.94 0.470.47 0 0 0 0 90 90 445 43.GG 61C61C 0.3000.300 nene 22.8022.80 23.6323.63 0 0 0 0 0 0 0 0 .GG 61C61C 0.3200.320 nene 24.3224.32 23.9123.91 0 0 0 0 0 0 0 0 11 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 sese 4.944.94 0.470.47 0 0 0 0 135 135 667 64 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 swsw 4.944.94 0.470.47 117 117 578 56 0 0 0 0 GG 61C61C 0.3000.300 swsw 22.8022.80 30.1130.11 0 0 0 0 0 0 0 0GG61C61C0.3200.320 swsw 24.3224.32 30.3930.39 0 0 0 0 0 0 0 0 DD 11P011P0 0.2900.290 swsw 22.0422.04 5.365.36 0 0 0 0 0 0 0 0WW12F-0sw12F-0sw 0.0650.065 nwnw 4.944.94 0.470.47 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nwnw 4.944.94 0.470.47 36 36 178 17 0 0 0 0CC16B-50ad16B-50ad 0.0200.020 --1.521.52 0.840.84 0 0 0 0 150 150 228 126FF19A-30bscp19A-30bscp 0.0340.034 --2.172.17 0.400.40 0 0 0 0 0 0 0 0 FF 21A-24t21A-24t 0.0250.025 --1.901.90 0.000.00 0 0 0 0 0 0 0 0FF22B-10cpm22B-10cpm 0.3550.355 --26.9826.98 0.000.00 52 17 459 0 0 0 0 0 FF 22B-10cpm22B-10cpm 0.3550.355 --26.9826.98 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion -6 -14 Envelope loss/gain 1214 67 1339 219 12 a)Infiltration 618 59 910 87 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)1833 126 2249 306 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0RedistributionRedistribution-1833 -126 0 014Subtotal002249306 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 0 0 2249 306 Air required (cfm)Air required (cfm)0 0 62 24 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Mar-11 08:38:47Right-Suite® Universal 2019 19.0.13 RSU20477 Page 3...Country\Wrightsoft\Eicap\SF13B7. princeton.rup Calc = MJ8 House faces: N SF13B7Job:Right-J® Worksheet Date:Entire House Vince ByramBy:High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryhtg@gmail.com 1 Room name Room4 Room5 2 Exposed wall 31.0 ft 14.0 ft3Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft250.0x1.0 ft242.0x1.0 5 Room area 250.0 ft²242.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12F-0sw12F-0sw 0.0650.065 nene 4.944.94 0.470.47 0 0 0 0 0 0 0 0.WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nene 4.944.94 0.470.47 0 0 0 0 126 101 499 48.GG 61C61C 0.3000.300 nene 22.8022.80 23.6323.63 0 0 0 0 0 0 0 0 .GG 61C61C 0.3200.320 nene 24.3224.32 23.9123.91 0 0 0 0 25 0 608 598 11 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 sese 4.944.94 0.470.47 144 144 711 68 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 swsw 4.944.94 0.470.47 135 106 524 50 0 0 0 0 GG 61C61C 0.3000.300 swsw 22.8022.80 30.1130.11 0 0 0 0 0 0 0 0GG61C61C0.3200.320 swsw 24.3224.32 30.3930.39 29 0 705 881 0 0 0 0 DD 11P011P0 0.2900.290 swsw 22.0422.04 5.365.36 0 0 0 0 0 0 0 0WW12F-0sw12F-0sw 0.0650.065 nwnw 4.944.94 0.470.47 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nwnw 4.944.94 0.470.47 0 0 0 0 0 0 0 0CC16B-50ad16B-50ad 0.0200.020 --1.521.52 0.840.84 250 250 380 210 242 242 368 203FF19A-30bscp19A-30bscp 0.0340.034 --2.172.17 0.400.40 0 0 0 0 0 0 0 0 FF 21A-24t21A-24t 0.0250.025 --1.901.90 0.000.00 0 0 0 0 0 0 0 0FF22B-10cpm22B-10cpm 0.3550.355 --26.9826.98 0.000.00 0 0 0 0 0 0 0 0 FF 22B-10cpm22B-10cpm 0.3550.355 --26.9826.98 0.000.00 0 0 0 0 60 3 94 0 6 c) AED excursion 316 -33 Envelope loss/gain 2320 1526 1568 816 12 a)Infiltration 1128 108 509 49 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)3448 1634 2078 865 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0RedistributionRedistribution000014Subtotal344816342078865 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 3448 1634 2078 865 Air required (cfm)Air required (cfm)96 129 58 69 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Mar-11 08:38:47Right-Suite® Universal 2019 19.0.13 RSU20477 Page 4...Country\Wrightsoft\Eicap\SF13B7. princeton.rup Calc = MJ8 House faces: N SF13B7Job:Right-J® Worksheet Date:Entire House Vince ByramBy:High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryhtg@gmail.com 1 Room name Room6 Room7 2 Exposed wall 26.0 ft 5.0 ft3Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft13.0x13.0 ft5.0x10.0 5 Room area 169.0 ft²50.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12F-0sw12F-0sw 0.0650.065 nene 4.944.94 0.470.47 0 0 0 0 0 0 0 0.WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nene 4.944.94 0.470.47 117 92 454 44 0 0 0 0.GG 61C61C 0.3000.300 nene 22.8022.80 23.6323.63 0 0 0 0 0 0 0 0 .GG 61C61C 0.3200.320 nene 24.3224.32 23.9123.91 25 0 608 598 0 0 0 0 11 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 sese 4.944.94 0.470.47 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 swsw 4.944.94 0.470.47 0 0 0 0 0 0 0 0 GG 61C61C 0.3000.300 swsw 22.8022.80 30.1130.11 0 0 0 0 0 0 0 0GG61C61C0.3200.320 swsw 24.3224.32 30.3930.39 0 0 0 0 0 0 0 0 DD 11P011P0 0.2900.290 swsw 22.0422.04 5.365.36 0 0 0 0 0 0 0 0WW12F-0sw12F-0sw 0.0650.065 nwnw 4.944.94 0.470.47 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nwnw 4.944.94 0.470.47 117 117 578 56 45 45 222 21CC16B-50ad16B-50ad 0.0200.020 --1.521.52 0.840.84 169 169 257 142 50 50 76 42FF19A-30bscp19A-30bscp 0.0340.034 --2.172.17 0.400.40 0 0 0 0 50 50 108 20 FF 21A-24t21A-24t 0.0250.025 --1.901.90 0.000.00 0 0 0 0 0 0 0 0FF22B-10cpm22B-10cpm 0.3550.355 --26.9826.98 0.000.00 0 0 0 0 0 0 0 0 FF 22B-10cpm22B-10cpm 0.3550.355 --26.9826.98 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion -34 -4 Envelope loss/gain 1897 805 407 79 12 a)Infiltration 946 91 182 17 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)2843 895 589 96 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0RedistributionRedistribution000014Subtotal284389558996 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 2843 895 589 96 Air required (cfm)Air required (cfm)79 71 16 8 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Mar-11 08:38:47Right-Suite® Universal 2019 19.0.13 RSU20477 Page 5...Country\Wrightsoft\Eicap\SF13B7. princeton.rup Calc = MJ8 House faces: N SF13B7Job:Right-J® Worksheet Date:Entire House Vince ByramBy:High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryhtg@gmail.com 1 Room name Room8 Room9 2 Exposed wall 14.0 ft 23.0 ft3Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft14.0x11.0 ft12.0x11.0 5 Room area 154.0 ft²132.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12F-0sw12F-0sw 0.0650.065 nene 4.944.94 0.470.47 0 0 0 0 0 0 0 0.WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nene 4.944.94 0.470.47 0 0 0 0 0 0 0 0.GG 61C61C 0.3000.300 nene 22.8022.80 23.6323.63 0 0 0 0 0 0 0 0 .GG 61C61C 0.3200.320 nene 24.3224.32 23.9123.91 0 0 0 0 0 0 0 0 11 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 sese 4.944.94 0.470.47 9 9 44 4 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 swsw 4.944.94 0.470.47 99 74 366 35 99 74 366 35 GG 61C61C 0.3000.300 swsw 22.8022.80 30.1130.11 0 0 0 0 0 0 0 0GG61C61C0.3200.320 swsw 24.3224.32 30.3930.39 25 0 608 760 25 0 608 760 DD 11P011P0 0.2900.290 swsw 22.0422.04 5.365.36 0 0 0 0 0 0 0 0WW12F-0sw12F-0sw 0.0650.065 nwnw 4.944.94 0.470.47 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nwnw 4.944.94 0.470.47 18 18 89 9 108 108 534 51CC16B-50ad16B-50ad 0.0200.020 --1.521.52 0.840.84 154 154 234 129 132 132 201 111FF19A-30bscp19A-30bscp 0.0340.034 --2.172.17 0.400.40 154 154 334 62 132 132 286 53 FF 21A-24t21A-24t 0.0250.025 --1.901.90 0.000.00 0 0 0 0 0 0 0 0FF22B-10cpm22B-10cpm 0.3550.355 --26.9826.98 0.000.00 0 0 0 0 0 0 0 0 FF 22B-10cpm22B-10cpm 0.3550.355 --26.9826.98 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion 276 274 Envelope loss/gain 1675 1275 1994 1284 12 a)Infiltration 509 49 837 80 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)2184 1324 2831 1364 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0RedistributionRedistribution000014Subtotal2184132428311364 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 2184 1324 2831 1364 Air required (cfm)Air required (cfm)61 105 79 108 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2021-Mar-11 08:38:47Right-Suite® Universal 2019 19.0.13 RSU20477 Page 6...Country\Wrightsoft\Eicap\SF13B7. princeton.rup Calc = MJ8 House faces: N SF13B7Job:Right-J® Worksheet Date:Entire House Vince ByramBy:High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryhtg@gmail.com 1 Room name Room10 Room11 2 Exposed wall 7.0 ft 15.0 ft3Room height 9.0 heat/coolft 9.0 heat/coolft 4 Room dimensions ft5.0x7.0 ft82.0x1.0 5 Room area 35.0 ft²82.0 ft² Ty Construction U-value Or HTM Area (ft²)Load Area (ft²)Load number (Btuh/ft²-°F)(Btuh/ft²-°F)(Btuh/ft²)(Btuh/ft²)or perimeter (ft)(Btuh)or perimeter (ft)(Btuh) Heat Cool Gross N/P/S Heat Cool Gross N/P/S Heat Cool 6 WW 12F-0sw12F-0sw 0.0650.065 nene 4.944.94 0.470.47 63 63 311 30 54 54 267 26.WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nene 4.944.94 0.470.47 0 0 0 0 0 0 0 0.GG 61C61C 0.3000.300 nene 22.8022.80 23.6323.63 0 0 0 0 0 0 0 0 .GG 61C61C 0.3200.320 nene 24.3224.32 23.9123.91 0 0 0 0 0 0 0 0 11 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 sese 4.944.94 0.470.47 0 0 0 0 0 0 0 0 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 swsw 4.944.94 0.470.47 0 0 0 0 0 0 0 0 GG 61C61C 0.3000.300 swsw 22.8022.80 30.1130.11 0 0 0 0 0 0 0 0GG61C61C0.3200.320 swsw 24.3224.32 30.3930.39 0 0 0 0 0 0 0 0 DD 11P011P0 0.2900.290 swsw 22.0422.04 5.365.36 0 0 0 0 0 0 0 0WW12F-0sw12F-0sw 0.0650.065 nwnw 4.944.94 0.470.47 0 0 0 0 81 81 400 38 WW Frm wall, vnl ext, 3 0.065Frm wall, vnl ext, 3 0.065 nwnw 4.944.94 0.470.47 0 0 0 0 0 0 0 0CC16B-50ad16B-50ad 0.0200.020 --1.521.52 0.840.84 0 0 0 0 0 0 0 0FF19A-30bscp19A-30bscp 0.0340.034 --2.172.17 0.400.40 0 0 0 0 0 0 0 0 FF 21A-24t21A-24t 0.0250.025 --1.901.90 0.000.00 35 35 66 0 82 82 156 0FF22B-10cpm22B-10cpm 0.3550.355 --26.9826.98 0.000.00 0 0 0 0 0 0 0 0 FF 22B-10cpm22B-10cpm 0.3550.355 --26.9826.98 0.000.00 0 0 0 0 0 0 0 0 6 c) AED excursion -2 -5 Envelope loss/gain 378 27 823 59 12 a)Infiltration 255 24 546 52 b)Room ventilation 0 0 0 0 13 Internal gains:Occupants @ 230230 0 0 0 0 Appliances/other 0 0 Subtotal (lines 6 to 13)632 52 1368 111 Less external loadLess external load 0 0 0 0 Less transferLess transfer 0 0 0 0RedistributionRedistribution0014029614Subtotal632522770208 15 Duct loads -0%0%0 0 -0%0%0 0 Total room load 632 52 2770 208 Air required (cfm)Air required (cfm)18 4 77 16 Job #: SF13B7 Performed by Vince Byram for: Cody Puzey 3758 Yellowstones Hwy Idaho Falls, Id 83401 Phone: 208-529-2116 High Country Heating P.O. Box 627 Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 highcountryhtg@gmail.com Scale: 1 : 63 Page 1 Right-Suite® Univ ersal 2019 19.0.13 RSU20477 2021-Mar-11 08:39:27 ...oft\Eicap\SF13B7. princeton.rup N 2nd Story Room3 Room4 Room5 Room6 Room7 Room8 Room9 65 cfm 62 cfm 65 cfm 69 cfm 105 cfm 108 cfm 108 cfm 105 cfm 76 cfm 79 cfm 158 cfm 79 cfm 16 cfm Job #: SF13B7 Performed by Vince Byram for: Cody Puzey 3758 Yellowstones Hwy Idaho Falls, Id 83401 Phone: 208-529-2116 High Country Heating P.O. Box 627 Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 highcountryhtg@gmail.com Scale: 1 : 63 Page 2 Right-Suite® Univ ersal 2019 19.0.13 RSU20477 2021-Mar-11 08:39:27 ...oft\Eicap\SF13B7. princeton.rup N Main Floor Room1 Room2 Room10 Room11 36'-0" 94 cfm 94 cfm 18 cfm 77 cfm 94 cfm 94 cfm 6 "6 " 6 "6 "6 " 470 cfm 6 "6 "6 " 6 " 6 " 20 x 8 6 "6 " 12 x 8 12 x 8 6 " 2-14x3.25 14x3.25 12 x 8 3-14x3.25 14x3.2514x3.25 20 x 8 6 " 14x3.25 2021-Mar-11 08:38:48 Right-Suite® Universal 2019 19.0.13 RSU20477 Page 1 ...Country\Wrightsoft\Eicap\SF13B7. princeton.rup Calc = MJ8 House faces: N SF13B7Job:Duct System Summary Date:Entire House Vince ByramBy: High Country Heating P.O. Box 627, Rigby, Id 83442 Phone: 208-745-8056 Fax: 208-745-0817 Email: highcountryhtg@gmail.com Project Information Cody PuzeyFor: 3758 Yellowstones Hwy, Idaho Falls, Id 83401 Phone: 208-529-2116 CoolingHeating External static pressure in H2O0.70in H2O0.70 Pressure losses in H2O0.34in H2O0.34 Available static pressure in H2O0.36in H2O0.36 Supply / return available pressure 0.191 / 0.169 in H2O in H2O0.191 / 0.169 Lowest friction rate in/100ft0.087in/100ft0.087 Actual air flow cfm767cfm920 Total effective length (TEL)ft413 Supply Branch Detail Table Design Htg Clg Design Diam H x W Duct Actual Ftg.Eqv Name (Btuh)(cfm)(cfm)FR (in)(in)Matl Ln (ft)Ln (ft)Trunk st1B180.039.0ShMt0x06.00.08758943376hRoom1 st1150.023.0ShMt0x06.00.11058943376hRoom1-A st1B170.049.0ShMt0x06.00.08758943376hRoom1-B st1A180.038.0ShMt0x06.00.08858943376hRoom1-C st1165.012.0ShMt0x06.00.108418632hRoom10 st1175.011.0ShMt0x06.00.10316772770hRoom11 st1A150.038.0ShMt0x06.00.10224622249hRoom3 st1A170.041.0ShMt0x06.00.0906548817cRoom4 st1A160.046.0ShMt0x06.00.0936548817cRoom4-A st1130.025.0ShMt0x06.00.1236958865cRoom5 st1160.016.0ShMt0x06.00.10871792843hRoom6 st1175.09.0ShMt0x06.00.104816589hRoom7 st1140.033.0ShMt0x06.00.110105611324cRoom8 st1175.020.0ShMt0x06.00.098108791364cRoom9 Supply Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk st1 Peak AVF 920 767 0.087 828 13.7 20x8 ShtMetl st1A Peak AVF 439 328 0.087 659 10.4 12x8 ShtMetl st1 st1B Peak AVF 188 116 0.087 281 7.6 12x8 ShtMetl st1A 2021-Mar-11 08:38:48 Right-Suite® Universal 2019 19.0.13 RSU20477 Page 2 ...Country\Wrightsoft\Eicap\SF13B7. princeton.rup Calc = MJ8 House faces: N Return Branch Detail Table Grille Htg Clg TEL Design Veloc Diam H x W Stud/Joist Duct Name Size (in)(cfm)(cfm)(ft)FR (fpm)(in)(in)Opening (in)Matl Trunk rb2 0x 790 71 105.0 0.161 250 4.8 3.25x14 10x9 SJSp rt1 rb4 0x 610 105 96.0 0.176 332 5.3 3.25x14 10x9 SJSp rt1 rb3 0x 790 108 127.0 0.133 342 5.7 3.25x14 10x9 SJSp rt1 rb1 0x 4700 253 191.0 0.089 495 10.6 3-3.25x14 3-10x27 SJSp rt1 rb6 0x 740 76 141.0 0.120 241 5.1 3.25x14 10x9 SJSp rt1 rb5 0x 1580 154 194.0 0.087 250 7.1 2-3.25x14 2-10x18 SJSp rt1A Return Trunk Detail Table Trunk Htg Clg Design Veloc Diam H x W Duct Name Type (cfm)(cfm)FR (fpm)(in)(in)Material Trunk rt1 Peak AVF 920 767 0.087 828 13.7 20x8 ShtMetl rt1A Peak AVF 158 154 0.087 237 7.1 12x8 ShtMetl rt1