HomeMy WebLinkAboutUPDATED PLANS - 20-00364 - 1092 Greenside Loop - Merdian New SFRElevations Scale: 1/4" & 1/8" =1'-0" on 36" x 24" Paper Scale: 1/8" & 1/16"=1'-0" on 17" x 11" Paper Front Elevation Back Elevation Right ElevationLeft Elevation A1 Su n d a n c e dr a f t i n g & d e s i g n PAGE LAYOUT A1-Elevations A2-Basement Foundation A3-Floor Plan A4-Bonus Room (Optional) A5-Cross Section A6-Plot Plan GENERAL NOTES: 1/4"=1'-0" UNO Me r i d i a n P l a n Pi n e B r o o k E s t a t e s D2 B 2 L 4 A6 of Sheet R. Blackburn, K. Earl Co p y r i g h t S u n d a n c e D r a f t i n g & D e s i g n 2 0 2 0 Copyright Sundance Drafting and Design 2020 D Size Paper 1/8"=1'-0" UNO B Size Paper Date Scale Drawn By: Reviewed By: Bid Set Permit Set T. Stoddart 6:12 Pitch Main 8:12 Pitch Front & Sides 10:12 Garage Bonus 9' Main Walls 9' Basement Foundation Walls Garage to Match Main TYP TOTAL SQ. FTG.= 3880 MAIN FLOOR=1938/1840 INTERIOR BASEMENT =1942/1732 INTERIOR Optional BONUS = 381 GARAGE =1038 20 8 . 5 2 4 . 2 8 8 0 N EE D AH OU S E P LA N . C O M 05-04-19 Sundance Drafting and Design tries to provide the most accurate information for your house design as possible, if design information is not provided correctly Sundance is not liable. Many factors occur in construction during the building process that change the continuity of this drawing. Due to these factors if the plan is not followed or changes occur after the final print has been given, Sundance Drafting and Design is not liable for those items. Read through all pages provided. Review all the notations and labels on each page. Engineering supersedes all drafting notations. Labeling by County or City Inspectors have to be followed. Footing, Foundation, Rebar, and Shear walls are specified and have to be followed. Floor Layouts and Truss Details are separate from these pages but need to be kept together and followed. If any problems with the plans, please notify Sundance Drafting and Design. The undersigned has looked through these pages and agrees that all discussed between Client/Contractor and Sundance Drafting and Design is noted and correct Please Initial Here These Plans follow the 2015 IRC Codes Permitting and Inspections Section 106,107,108, & 109 1. For a permit you will need 2 sets of the following: House plans, Floor Layout, Truss Details, Rescheck, Heat Loss Analysis, and Engineer Stamp (if needed). 2. Review entire set of plans including the above described with owner/contractor. 3. This drawing is drawn by an AutoCad Design Specialist not an Architect. All Details should be looked over and approved by contractor before construction begins. Sundance Drafting and Design is not liable for construction mistakes. 4. This drawing is not to be duplicated without written or verbal consent by Tiffany Stoddart. Copyright Sundance Drafting and Design 2020 06-25-19 12 Shake Shingles 12 8 12 10 Cricket Pergola Vertical Siding Faux Stone Line of Optional Bonus Room 9:12 Metal Seam Roof 12 6 12 6 12 10 12 10 Top of Foundation Wall to Curb or Street need to be Min. 24" Elevation Rev. Rev. Rev. 08-19-19 MATERIALS Vertical Siding=327 SF Horizontal Siding=1183 SF Faux Stone=269 SF Shakes=30 SF Soffit = 386 LF PERMIT SET 03-10-20 12-07-20 Horiz. Siding 12 10 12 12 8 Foundation Plan Scale: 1/4"=1'-0" D Size Paper Scale: 1/8"=1'-0" B Size Paper Ventilation R408.1 The under-floor space between the bottom of the floor joists and the earth under any building (except space occupied by a basement) shall have ventilation openings through foundation walls or exterior walls. The minimum net area of ventilation opening shall not be less than 1 s/f for each 150 s/f of under floor space area, unless the ground surface is covered by a Class 1 vapor retarder material. If the vapor retarder is used the min. net area of ventilation openings shall not be less than 1 s/f for each 1500 s/f. One such vent shall be within 3' of each corner of building. Header Notes: Headers 4' or less use 1 Ply 9.50 or 2 Ply 2x10 Dim. Lumber Headers 6' or less use 2 Ply 9.50 Headers 8' or less use 3 Ply 9.50 or 2 Ply 11.88 ML Headers 10' or less use 3 Ply 11.88 or 2 Ply 14.00 ML Headers 10' or more refer to TJXpert Layout Exhaust and Ventilation: Whole House Fan 80 CFM Kitchen Fan 100 CFM Laundry 50 CFM Bathrooms 50 CFM Bedrooms 10 CFM fresh air Living Areas 10 CFM fresh air Contractor to indicate location of fans if not indicated on plans already. GFoundation Wall System: 2x6 Treated Sill Plate over Foam Sill Sealer with 1 2" Anchor Bolts @ 32" O.C. 10" Long, 7" Embedded Max. 12" from all Corners or Splices Concrete Wall Greater than 9' need to have an Architects or Engineer Seal 8' & under (1) Horiz. Bar in top 12" and one at mid-height 8'-1" to 9' (1) Horiz. Bar in top 12" & one bar at each third point Min. (2) Anchor Bolts per Sill Plate w/ nut & SQUARE plate Washer 3x3x1/4" Min. For each Bolt over Concrete Foundation wall Consistent w/ 2012 IRC R401-403 With Asphalt Emulsion on Exterior Side over Continuous Concrete Footings Consistent w/ 2012 IRC Section R106.1 over Undisturbed Soil Window Well System: 2015 IRC Code Min. egress window opening will be 5.7 sq. ft 7 Sill height no higher than 44" above FFL Window wells provide a net clear of 9 sq. ft. w/min horiz. projection & width of 36" Exception: Window Wells w/depth greater than 44" will have a permanently affixed ladder or steps. Ladder or Steps 12"-width Inside, 3"-from walls, Spaced no more than 18" O.C. J Header Notes: Headers 4' or less use 1 Ply 9.50 or 2 Ply 2x10 Dim. Lumber Headers 6' or less use 2 Ply 9.50 Headers 8' or less use 3 Ply 9.50 or 2 Ply 11.88 ML Headers 10' or less use 3 Ply 11.88 or 2 Ply 14.00 ML Headers 10' or more refer to TJXpert Layout A2A2 Su n d a n c e dr a f t i n g & d e s i g n PAGE LAYOUT A1-Elevations A2-Basement Foundation A3-Floor Plan A4-Bonus Room (Optional) A5-Cross Section A6-Plot Plan GENERAL NOTES: 1/4"=1'-0" UNO Me r i d i a n P l a n Pi n e B r o o k E s t a t e s D2 B 2 L 4 A6 of Sheet R. Blackburn, K. Earl Co p y r i g h t S u n d a n c e D r a f t i n g & D e s i g n 2 0 2 0 Copyright Sundance Drafting and Design 2020 D Size Paper 1/8"=1'-0" UNO B Size Paper Date Scale Drawn By: Reviewed By: Bid Set Permit Set Smoke Alarms 2015 IRC Code Section 106. R314 All smoke alarms shall be listed in accordance with UL 217 & installed in accordance with NFPA 72 -One in each sleeping area -Outside of each separate sleeping area in the immediate vicinity of the bedrooms -On each additional story including un-finish & finished basements and habitable attics but not including crawl spaces and uninhabitable attics. In dwellings or dwelling units with splits levels and without an intervening door between the adjacent levels a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level. -Alarm devices shall be interconnected with battery backup that the actuation of one alarm will activate all of the alarms S Carbon Monoxide Alarms 2015 IRC Section 106 & R315.1 New Construction an approved carbon monoxide alarm installed outside of each sleeping area in the immediate vicinity of bedroom and dwelling units. They shall be listed as complying with UL 2034 and installed accordingly CM T. Stoddart 9' Main Walls 9' Basement Foundation Walls Garage to Match Main TYP TOTAL SQ. FTG.= 3880 MAIN FLOOR=1938/1840 INTERIOR BASEMENT =1942/1732 INTERIOR Optional BONUS = 381 GARAGE =1038 20 8 . 5 2 4 . 2 8 8 0 N EE D AH OU S E P LA N . C O M 26 6 8 2x6 Wall WIC T-Wall 4" Conc. Pour Ove r Undisturb e d Soil 1 66' 25'-2"12'-10" 38' 21 ' - 2 " 7' 10 ' - 1 0 " 11 ' - 2 " 6'-6"6'-4" TRIPLE CAR GARAGE 4" CONCRETE SLAB SLOPE CONC. FLOOR TO DRAIN TO GARAGE DOOR HOLDDOWN: H1 SIMPSON STRONG TIE STHD14-INSTALLED & NAILED AS PER MANUFACTURERS RECOMMENDATIONS CONCRETE TO WOOD CONNECTION Cantilever Above 28 ' - 2 " 22 ' 44 ' - 6 " 14 ' - 2 " 58 ' - 8 " 13' 05-04-19 28' 66' Cut 3' for Passage Opening with Req. Blocking Cut 18' for Garage Door opening with Req. Blocking Cu t 9 ' f o r G a r a g e Do o r o p e n i n g wi t h R e q . B l o c k i n g Raised Concrete Patio Above 1' - 6 " Linen Bedroom 4 11'-2" x 12'-8" 10 CFM Fresh Air Smoke Detector Linen Bath 50 CFM 59 SF Tile Bedroom 5 11'-2" x 12'-8" 10 CFM Fresh Air Smoke Detector Mech. 3' Clearance in front of Furnance Seismic Straps around WH Furn WH WS Up to Main Storage 8'-10"x 9'-2" UNFINISHED 9' Basement F. Walls Family Room 24'-8" x 23'-5" 10 CFM Fresh Air Fl o o r J o i s t D i r e c t i o n Fl o o r J o i s t D i r e c t i o n 26 6 8 28 6 8 2868 2 6 6 8 2468 2468 20 6 8 2868 Beam 30 6 8 Beam 12 ' - 5 " 13 ' - 1 0 " 18 ' - 3 " 10'-5" AV/Shelves Theater 12'-10" x 17'-0" 30 6 8 B a r n 24 6 8 3068 20 3 0 Play Area Under Stairs 2020 Window Opening Optional Gas Fireplace J 5040 SV J 5040 SV J 5040 SV 2668 P 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Sundance Drafting and Design tries to provide the most accurate information for your house design as possible, if design information is not provided correctly Sundance is not liable. Many factors occur in construction during the building process that change the continuity of this drawing. Due to these factors if the plan is not followed or changes occur after the final print has been given, Sundance Drafting and Design is not liable for those items. Read through all pages provided. Review all the notations and labels on each page. Engineering supersedes all drafting notations. Labeling by County or City Inspectors have to be followed. Footing, Foundation, Rebar, and Shear walls are specified and have to be followed. Floor Layouts and Truss Details are separate from these pages but need to be kept together and followed. If any problems with the plans, please notify Sundance Drafting and Design. The undersigned has looked through these pages and agrees that all discussed between Client/Contractor and Sundance Drafting and Design is noted and correct Please Initial Here These Plans follow the 2015 IRC Codes Permitting and Inspections Section 106,107,108, & 109 1. For a permit you will need 2 sets of the following: House plans, Floor Layout, Truss Details, Rescheck, Heat Loss Analysis, and Engineer Stamp (if needed). 2. Review entire set of plans including the above described with owner/contractor. 3. This drawing is drawn by an AutoCad Design Specialist not an Architect. All Details should be looked over and approved by contractor before construction begins. Sundance Drafting and Design is not liable for construction mistakes. 4. This drawing is not to be duplicated without written or verbal consent by Tiffany Stoddart. Copyright Sundance Drafting and Design 2020 6' - 8 " 11 ' - 6 " 19 ' - 6 " 6' - 1 0 " Center of Footing Center of Footing 24 ' - 8 " 13'-9" 6' - 1 1 " 8' - 7 " Center of Footings 9'-9" 4'11'-1"17'-1"11'-1" 3'-2"3'-2"7'-11" 6' - 4 " 7' 18 ' - 3 " 12 ' - 9 " 4' - 2 " 14'-3" 1' - 6 " 5' 1' - 7 " 4' - 8 " 1' 14'-1" 12 ' - 7 " 6' - 5 " 5' - 5 " 3' - 1 0 " 3'-8"9'3'-4"9'-2" 5'-10"11'-2"11' 8'-10" 8' - 8 " 1' - 4 " Center of Footing Center of Footing 2' - 8 " Center of Footings 11' 11' 24 ' - 2 " 4" Conc. P o u r O v e r Undistur b e d S o i l WIC 2 " R o c k Le d g e 2" R o c k L e d g e 2" Rock Ledge 5' 4'-9"3'-4"14'-1" 7'-2" S CM S CM H1 H1 H1 H1 H1H1H1H1 2 " R o c k L e d g e 1' 2" Rock Ledge 06-25-19 Wet Bar Rev. Rev. Rev. 31 ' 28'-2" 3'-8" Bedroom 6 16'-4" x 11'-6" 10 CFM Fresh Air Smoke Detector 08-19-19 PERMIT SET 03-10-20 Beam to Be Flush w/ Ceiling 12-07-20 11'-4"23'-4"18'-4" 66' 10 ' 7' 10 ' 68 ' - 2 " 6' - 5 " 5' - 1 0 " H1 H1 6'-3 1/2"15'-5 1/2" Main Floor Scale: 1/4"=1'-0" D Size Paper Scale: 1/8"=1'-0" B Size Paper Furnace: Location of furnace and water heater 2015 IRC, Section R106, and M1305 Elevate all sources of ignition in the garage a min. of 18" above the floor 2015 IRC, Sections R106, and M1307.3 Provide a protection post in the garage to prevent vehicle damage to furnace and water heater. 2015 IRC, Section R106, M1307.3.1 Crawl Space: Through Floor min 18"x24" or through perimeter wall min 16"x24" required crawl space opening. If applicable, refer to mechanical code for access requirements where mechanical equipment is located under floors. 2012 IRC, Section R106, R408.4 M1305.1.4 Smoke Alarms 2015 IRC Code Section 106. R314 All smoke alarms shall be listed in accordance with UL 217 & installed in accordance with NFPA 72 -One in each sleeping area -Outside of each separate sleeping area in the immediate vicinity of the bedrooms -On each additional story including un-finish & finished basements and habitable attics but not including crawl spaces and uninhabitable attics. In dwellings or dwelling units with splits levels and without an intervening door between the adjacent levels a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level. -Alarm devices shall be interconnected with battery backup that the actuation of one alarm will activate all of the alarms S Carbon Monoxide Alarms 2015 IRC Section 106 & R315.1 New Construction an approved carbon monoxide alarm installed outside of each sleeping area in the immediate vicinity of bedroom and dwelling units. They shall be listed as complying with UL 2034 and installed accordingly CM 3' Nailing or Screws 7" O.C. Max Horiz. & Vert. Blocks at Drywall Joints for 7" O.C. Screws of Nails Drywall is shown cutaway Overlapped Double Plate 2x6 Exterior wall @16"O.C. with 7/16" Waferboard Drywall & Waterboard not Shown for clarity 2x4 Interior Wall @16" O.C. 4'x8' Shear Panel on Both Sides 3' 8'x8' Shear Panel on Single Side 48 . 5 " t o c n t r Header Notes: Headers 4' or less use 1 Ply 9.50 or 2 Ply 2x10 Dim. Lumber Headers 6' or less use 2 Ply 9.50 Headers 8' or less use 3 Ply 9.50 or 2 Ply 11.88 ML Headers 10' or less use 3 Ply 11.88 or 2 Ply 14.00 ML Headers 10' or more refer to TJXpert Layout 3' Hallway Clearance 2015 IRC, Section R106 and R311.6 Saftey Glazing 2012 IRC, Sections R106 and R308.4.5 Exhaust and Ventilation: Whole House Fan 80 CFM Kitchen Fan 100 CFM Laundry 50 CFM Bathrooms 50 CFM Bedrooms 10 CFM fresh air Living Areas 10 CFM fresh air Contractor to indicate location of fans if not indicated on plans already. A3 Su n d a n c e dr a f t i n g & d e s i g n PAGE LAYOUT A1-Elevations A2-Basement Foundation A3-Floor Plan A4-Bonus Room (Optional) A5-Cross Section A6-Plot Plan GENERAL NOTES: 1/4"=1'-0" UNO Me r i d i a n P l a n Pi n e B r o o k E s t a t e s D2 B 2 L 4 A6 of Sheet R. Blackburn, K. Earl Co p y r i g h t S u n d a n c e D r a f t i n g & D e s i g n 2 0 2 0 Copyright Sundance Drafting and Design 2020 D Size Paper 1/8"=1'-0" UNO B Size Paper Date Scale Drawn By: Reviewed By: Bid Set Permit Set T. Stoddart 9' Main Walls 9' Basement Foundation Walls Garage to Match Main TYP TOTAL SQ. FTG.= 3880 MAIN FLOOR=1938/1840 INTERIOR BASEMENT =1942/1732 INTERIOR Optional BONUS = 381 GARAGE =1038 20 8 . 5 2 4 . 2 8 8 0 N EE D AH OU S E P LA N . C O M 18 ' x 8 ' O H G a r a g e D o o r 3068 Pantry 2-3050 SH 28 6 8 26 6 8 28 6 8 24 6 8 C O 4040 Fix TempGFP DW REF 3'3' 6'6'6'-6" 66' 5' 24'-10"28'-2" 66' 24 ' 1' - 6 " 3' 2' - 8 " 3' 2' - 6 " 5' - 4 " 4' - 2 " 14 ' 15 ' 58 ' - 6 " 5'-6"5'-6"5'-6"5'-6" 6'-2"11'11' 10'-8" 3'-4"7'-10"5'-7 1/2" 16 ' - 1 0 " 9' x 8' OH Garage Door WIC 9' - 6 " 4' - 8 " 24 ' - 1 0 " 2468 12 ' 28 ' 5' - 6 " Be n c h 2' 18 ' 2' Bedroom 3 10'-8" x 11'-0" 10 CFM Fresh Air 9' Flat Ceiling Smoke Detector Carpet Master Bedroom 13'-6" x 14'-0" 10 CFM Fresh Air 9' Tray Ceiling Smoke Detector Carpet M.Bath 50 CFM 100 SF Tile 3 Car Garage Flat Work = 1008 SF Garage Floor 7" Reveal in Back 11" Reveal in Front to Top of Floor Contractor to locate exact location of req'd 22" x 30" Attic Access Point Min. 30" Vert. Head Room Clearance (2009-R807.1) Kitchen 10'-0" x 17'-0" 100 CFM 9' Ceiling 210 SF Tile Hall 22 ' 13' 2'9'2' 21 ' 7' 4'-5"4'-5" 11" Min. Steps 2' - 2 " Vapor Barrier Optional Up To Bonus 9' Ceiling 86 SF Tile PF H PFH 3050 SH 3050 SH IBWP 3 Interior Braced Wall Panel IBWP 2015 IRC Section 602.10.1 BWP 3-Interior Braced Wall Method 3 (IRC R602.10) 2x4 Studs @ 16" O.C. w/7/16" OSB Nailed 5" O.C. and 10" Field IBWP 5-Interior Braced Wall Method 5 1/2" min. Gypsum board 48" length applied to both sides OR 96" to one side covering 3 studs spaced 16" or 2 studs spaced 24" apart, blocked Screwed @7"/7" w/1" Drywall Screws All Vert Joints occur over stud All Hori. Joints blocked w/2x4 blocking Braced Wall Panel BWP 3' Braced Walls at each strap with 7/16" OSB one side, blocked in all joints Nailed @ 6"/12" w/ 8d or Stapled @ 4"/8" w 16 ga. All joints must occur over raming member 6" at edge 12" in field 4' 8d @ 12" O.C. in field 8d Nails @ 6" O.C. @ edge Braced Wall Panel Detail BWP IBWP 5 All exterior wall are braced walls. Garage Portals: Alternate Braced Wall Panel Garage Portal Design PFH See Figure R602.10.6.2 Sheet A4 PFH 05-04-19 S CM S S 28 6 8 Linen 2068 P Bedroom 2 10'-0" x 11'-10" 10 CFM Fresh Air 9' Flat Ceiling Smoke Detector Carpet 2-2468 Bath 50 cfm 49 SF Tile 4' - 6 " 2' - 8 " 6' 3' 2'-6" 4'-6" 36 6 8 C O 11' Cap Plate Entry 43 SF Tile PF H S IB W P 5 PFH Ra i s e d B a r 13' 4050 SH4050 SH 26 6 8 Be a m Op t i o n a l B o n u s 1 0 : 1 2 p i t c h w / 1 6 " h e e l 5010 Trans. 6010 Tra 2-3050 SH 6010 Tra 1'2-3050 SH 6010 Tra 3050 SH 3'-8" 16' 3010 Tra T 5050 SH Higher Header 4010 Tra4010 Tra 40 5 0 S H 40 1 0 T r a 4010 SV 5050 SH Higher Header Do w n 26 6 8 2-2468 30 6 8 30 6 8 28 6 8 1 2 3 4 5 1234567 (2) 7" Newel Post 9' - 6 " Railing 3'-4" 2' Roof Outline Covered Porch 42 SF 60 SF Hearth & Rock Front To Ceiling (Estimate Only) Sundance Drafting and Design tries to provide the most accurate information for your house design as possible, if design information is not provided correctly Sundance is not liable. Many factors occur in construction during the building process that change the continuity of this drawing. Due to these factors if the plan is not followed or changes occur after the final print has been given, Sundance Drafting and Design is not liable for those items. Read through all pages provided. Review all the notations and labels on each page. Engineering supersedes all drafting notations. Labeling by County or City Inspectors have to be followed. Footing, Foundation, Rebar, and Shear walls are specified and have to be followed. Floor Layouts and Truss Details are separate from these pages but need to be kept together and followed. If any problems with the plans, please notify Sundance Drafting and Design. The undersigned has looked through these pages and agrees that all discussed between Client/Contractor and Sundance Drafting and Design is noted and correct Please Initial Here These Plans follow the 2015 IRC Codes Permitting and Inspections Section 106,107,108, & 109 1. For a permit you will need 2 sets of the following: House plans, Floor Layout, Truss Details, Rescheck, Heat Loss Analysis, and Engineer Stamp (if needed). 2. Review entire set of plans including the above described with owner/contractor. 3. This drawing is drawn by an AutoCad Design Specialist not an Architect. All Details should be looked over and approved by contractor before construction begins. Sundance Drafting and Design is not liable for construction mistakes. 4. This drawing is not to be duplicated without written or verbal consent by Tiffany Stoddart. Copyright Sundance Drafting and Design 2020 4'-4"4'-4"3'-8" 2x6 Wall 2x6 Wall 4'-6"4' 2' - 6 " 2' - 6 " 5' 2' - 8 " 12 ' - 4 " 9"4'-8"9" 8" 11026 Tra 7'-8" 8' - 4 " 4 ' - 5 1 / 2 " 4'- 0 1 / 2 " 3 ' - 1 1 1 / 2 "7' 3'-1"5'-11"11'11' 4'-4"6'-8" 13' 1' 5' H1 7' 4' 6' - 2 " 4' - 8 " 13 ' - 2 " 31 ' 3' - 9 " 3' - 3 " 2'-8" 3 ' - 1 " 4'-10"6'3'-4"11'-5"13'-6" 2468 Op. 8'-10" 3'-11"3'-4"3'-4" 5' - 8 " 5' 1' - 6 " Utility 50 CFM 80 WHF 60 SF Tile Great Room 24'-2" x 24'-10" 10 CFM Fresh Air 9' w/ Box & Coffered Ceiling 06-25-19 44 ' - 6 " 53' Rev. Rev. Rev. 20min Fire Rated 1-3/8" Solid Door or Equal 1 Hr Fire Rating NO PENETRATIONS IBWP 5 (4') IBWP 5 (4') 08-19-19 28 6 8 PERMIT SET 03-10-20 Gl a s s 23' 5'-7"4'-10" 34'-6" Raised Covered Patio 10' Ceiling Height Temp Oven Micro Dining 14'-0" x 9'-0" 100 CFM 9' Boxed Ceiling 125 SF Tile 4'3'-4"24'-8" 12-07-20 2-6x6 Posts H1 IB W P 5 6' - 8 " 7' - 6 " 2'-4"H1 8' - 6 " 29'-2"3'-4" 3'-10 1/2" 10 ' Scale: 1/4"=1'-0" D Size Paper Scale: 1/8"=1'-0" B Size Paper Header Notes: Headers 4' or less use 1 Ply 9.50 or 2 Ply 2x10 Dim. Lumber Headers 6' or less use 2 Ply 9.50 Headers 8' or less use 3 Ply 9.50 or 2 Ply 11.88 ML Headers 10' or less use 3 Ply 11.88 or 2 Ply 14.00 ML Headers 10' or more refer to TJXpert Layout Exhaust and Ventilation: Whole House Fan 80 CFM Kitchen Fan 100 CFM Laundry 50 CFM Bathrooms 50 CFM Bedrooms 10 CFM fresh air Living Areas 10 CFM fresh air Contractor to indicate location of fans if not indicated on plans already. 4' Nailing or Screws 7" O.C. Max Horiz. & Vert. Blocks at Drywall Joints for 7" O.C. Screws of Nails Drywall is shown cutaway Overlapped Double Plate 2x6 Exterior wall @16"O.C. with 7/16" Waferboard Drywall & Waterboard not Shown for clarity 2x4 Interior Wall @16" O.C. 4'x8' Shear Panel on Both Sides 4' 8'x8' Shear Panel on Single Side 48 . 5 " t o c n t r IBWP 3 Interior Braced Wall Panel IBWP 2015 IRC Section 602.10.1 BWP 3-Interior Braced Wall Method 3 (IRC R602.10) 2x4 Studs @ 16" O.C. w/7/16" OSB Nailed 5" O.C. and 10" Field IBWP 5-Interior Braced Wall Method 5 1/2" min. Gypsum board 48" length applied to both sides OR 96" to one side covering 3 studs spaced 16" or 2 studs spaced 24" apart, blocked Screwed @7"/7" w/1" Drywall Screws All Vert Joints occur over stud All Hori. Joints blocked w/2x4 blocking Braced Wall Panel BWP 3' Braced Walls at each strap with 7/16" OSB one side, blocked in all joints Nailed @ 6"/12" w/ 8d or Stapled @ 4"/8" w 16 ga. All joints must occur over raming member 6" at edge 12" in field 4' 8d @ 12" O.C. in field 8d Nails @ 6" O.C. @ edge Braced Wall Panel Detail BWP IBWP 5 All exterior wall are braced walls. Optional Bonus Room A4A4 Su n d a n c e dr a f t i n g & d e s i g n PAGE LAYOUT A1-Elevations A2-Basement Foundation A3-Floor Plan A4-Bonus Room (Optional) A5-Cross Section A6-Plot Plan GENERAL NOTES: 1/4"=1'-0" UNO Me r i d i a n P l a n Pi n e B r o o k E s t a t e s D2 B 2 L 4 A6 of Sheet R. Blackburn, K. Earl Co p y r i g h t S u n d a n c e D r a f t i n g & D e s i g n 2 0 2 0 Copyright Sundance Drafting and Design 2020 D Size Paper 1/8"=1'-0" UNO B Size Paper Date Scale Drawn By: Reviewed By: Bid Set Permit Set 10:12 Pitch Bonus Trusses w/ 16" Heel 9' Main Walls 9' Basement Foundation Walls Garage to Match Main TYP Smoke Alarms 2015 IRC Code Section 106. R314 All smoke alarms shall be listed in accordance with UL 217 & installed in accordance with NFPA 72 -One in each sleeping area -Outside of each separate sleeping area in the immediate vicinity of the bedrooms -On each additional story including un-finish & finished basements and habitable attics but not including crawl spaces and uninhabitable attics. In dwellings or dwelling units with splits levels and without an intervening door between the adjacent levels a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level. -Alarm devices shall be interconnected with battery backup that the actuation of one alarm will activate all of the alarms S Carbon Monoxide Alarms 2015 IRC Section 106 & R315.1 New Construction an approved carbon monoxide alarm installed outside of each sleeping area in the immediate vicinity of bedroom and dwelling units. They shall be listed as complying with UL 2034 and installed accordingly CM T. Stoddart TOTAL SQ. FTG.= 3880 MAIN FLOOR=1938/1840 INTERIOR BASEMENT =1942/1732 INTERIOR Optional BONUS = 381 GARAGE =1038 20 8 . 5 2 4 . 2 8 8 0 N EE D AH OU S E P LA N . C O M Optional Bonus Room 12'-11" x 27'-0" 10:12 Attic Trusses w/ 16" Heel 375 SF 05-04-19 1' - 4 " 8" s p r a y F o a m I n s u l a t i o n 12 10 8' 4' - 6 " 12'-11 1/2"5'-11"5'-11"1'-6"1'-6" 23456789101112131415 16 2-3040 SH 6' C e i l i n g H e i g h t 7' C e i l i n g H e i g h t 8' C e i l i n g H e i g h t 4' - 6 " S i d e w a l l w / 8 " T o p C h o r d 6' C e i l i n g H e i g h t 7' C e i l i n g H e i g h t 8' C e i l i n g H e i g h t 4' - 6 " S i d e w a l l w / 8 " T o p C h o r d 12'-11 1/2"5'-11"5'-11" 6'-6"6'-6" 24'-10" 11'-8 1/2" 9'-3 1/2" 25' 5' - 2 " 27 ' - 6 " 5'-11"3'-6"4'-2"5'-7"5'-7" Down To Main 4' 15'-8 1/2" Stair Opening 6' - 8 " 3'-6" Stair System: 2015 IRC R302.7, 311.7.2, R311.7 R312.1.3 Eq. Stair Risers 7 3/4" Max. height, Eq. Stair Treads 10" Min. depth over (3) 11.5" MIN. Stair Stringers bolted at bottom with P.T. 2x4 -3 places with 3" x 1 2" Ø bolt and top securely mounted to framing with Simpson A35 Connector at Stairs Stringer to Ledger or alternate approved connection. with Cont. Handrail System mounted 36"above stair plane. with Handrail return to wall. with a Min. 6'-8" Head Clearance above stair plane. with all other Railing System to be min. 42" above FFL & meet current building codes for vert. and horiz. loading. Slate Spacing to no more than 4" sphere to pass thru. 12" Gypsum Board under stairs 2% Slope Max 1 to 48 H Sundance Drafting and Design tries to provide the most accurate information for your house design as possible, if design information is not provided correctly Sundance is not liable. Many factors occur in construction during the building process that change the continuity of this drawing. Due to these factors if the plan is not followed or changes occur after the final print has been given, Sundance Drafting and Design is not liable for those items. Read through all pages provided. Review all the notations and labels on each page. Engineering supersedes all drafting notations. Labeling by County or City Inspectors have to be followed. Footing, Foundation, Rebar, and Shear walls are specified and have to be followed. Floor Layouts and Truss Details are separate from these pages but need to be kept together and followed. If any problems with the plans, please notify Sundance Drafting and Design. The undersigned has looked through these pages and agrees that all discussed between Client/Contractor and Sundance Drafting and Design is noted and correct Please Initial Here These Plans follow the 2015 IRC Codes Permitting and Inspections Section 106,107,108, & 109 1. For a permit you will need 2 sets of the following: House plans, Floor Layout, Truss Details, Rescheck, Heat Loss Analysis, and Engineer Stamp (if needed). 2. Review entire set of plans including the above described with owner/contractor. 3. This drawing is drawn by an AutoCad Design Specialist not an Architect. All Details should be looked over and approved by contractor before construction begins. Sundance Drafting and Design is not liable for construction mistakes. 4. This drawing is not to be duplicated without written or verbal consent by Tiffany Stoddart. Copyright Sundance Drafting and Design 2020 24'-10" 11 ' - 1 1 1 / 2 " Half Wall 06-25-19 Rev. Rev. Rev. 9' 6' - 8 " 3' 3 6 ° 16'- 1 1 / 2 " H Scale: 1/4"=1'-0" Hea d r o o m H e i g h t Han d r a i l H e i g h t 10 1/2" 7 3 / 8 " Stringer Intermediate Support 08-19-19 03-10-20 12-07-20 PERMIT SET Su n d a n c e dr a f t i n g & d e s i g n PAGE LAYOUT A1-Elevations A2-Basement Foundation A3-Floor Plan A4-Bonus Room (Optional) A5-Cross Section A6-Plot Plan GENERAL NOTES: 1/4"=1'-0" UNO Me r i d i a n P l a n Pi n e B r o o k E s t a t e s D2 B 2 L 4 A6 of Sheet R. Blackburn, K. Earl Co p y r i g h t S u n d a n c e D r a f t i n g & D e s i g n 2 0 2 0 Copyright Sundance Drafting and Design 2020 D Size Paper 1/8"=1'-0" UNO B Size Paper Date Scale Drawn By: Reviewed By: Bid Set Permit Set T. Stoddart TOTAL SQ. FTG.= 3880 MAIN FLOOR=1938/1840 INTERIOR BASEMENT =1942/1732 INTERIOR Optional BONUS = 381 GARAGE =1038 20 8 . 5 2 4 . 2 8 8 0 N EE D AH OU S E P LA N . C O M 05-04-19 Sundance Drafting and Design tries to provide the most accurate information for your house design as possible, if design information is not provided correctly Sundance is not liable. Many factors occur in construction during the building process that change the continuity of this drawing. Due to these factors if the plan is not followed or changes occur after the final print has been given, Sundance Drafting and Design is not liable for those items. Read through all pages provided. Review all the notations and labels on each page. Engineering supersedes all drafting notations. Labeling by County or City Inspectors have to be followed. Footing, Foundation, Rebar, and Shear walls are specified and have to be followed. Floor Layouts and Truss Details are separate from these pages but need to be kept together and followed. If any problems with the plans, please notify Sundance Drafting and Design. The undersigned has looked through these pages and agrees that all discussed between Client/Contractor and Sundance Drafting and Design is noted and correct Please Initial Here These Plans follow the 2015 IRC Codes Permitting and Inspections Section 106,107,108, & 109 1. For a permit you will need 2 sets of the following: House plans, Floor Layout, Truss Details, Rescheck, Heat Loss Analysis, and Engineer Stamp (if needed). 2. Review entire set of plans including the above described with owner/contractor. 3. This drawing is drawn by an AutoCad Design Specialist not an Architect. All Details should be looked over and approved by contractor before construction begins. Sundance Drafting and Design is not liable for construction mistakes. 4. This drawing is not to be duplicated without written or verbal consent by Tiffany Stoddart. Copyright Sundance Drafting and Design 2020 06-25-19 Rev. Rev. Rev. 08-19-19 PE R M I T S E T 03-10-20 12-07-20 Cross Section Scale: 1/4"=1'-0" UNO D Size Paper Scale: 1/8"=1'-0" UNO B Size Paper Us e t h i s t a b l e u n l e s s a s o i l t e s t i s d o n e Taped and Prep'd for Interior Finishes over 1/2" Sheetrock on Ceiling Side connected to Rim Joist, spliced using gal. metal ties fastened w/6 16d nails ea. side not less than .058" x 1.5" wide 2012 IRC, Section R106 and R308.4.5 7/16" APA OSB & Nailing Pattern 6"-edge 12"-field Taped Prep'd for Interior Finishes Series, Placement, & O.C. Spacing as determined & indicated on TJXpert Layout. (Version 6.0 or later) over 11-7/8 TJI Engineered Floor Joist 3/4" T&G OSB Sub-floor Glued & Nailed 2x4 Stud framed @ 24" O.C. Floor System: with (2) 2x4 Top Plates with (1) 2x4 Bottom Plate with 1/2" Sheetrock Both Sides with min. R-21 Batt Insulation Interior Walls: with 1/2" Sheetrock Inside Occupancy separation between with (1) 2x6 Bottom Plate with (2) 2x6 Top Plates 2x6 Stud framed @ 24" O.C. UNO 2x6 Fascia Board with 3" Continuous Soffit Venting with add'l 2x4 Support as Required Exterior Walls: with 3/8" Soffit Sheeting with style "D" Metal Drip Edge Soffit System: A C E D B Alternate Reinforcing Bar Size and Spacing Vertical Rebar Only 8" nominal wall thickness 72" Max rebar spacing #4 @ 15" is equal to #5 @ 23" or #6 @ 32" #4 @ 16" is equal to #5 @ 25" or #6 @ 32" #4 @ 16" is equal to #5 @ 25" or #6 @ 36" Load-Bearing Value of Soil (psf) 1500 2000 3000 Conventional Light-frame Construction 1-story 2-story 3-story 4" Brick Veneer over light frame 1-story 2-story 3-story 12 21 32 12 16 24 12 15 23 12 12 17 12 12 16 Table R403.1 Min. Width of Conc. or Masonry Footings (inches) S Exhaust and Ventilation: Whole House Fan 80 CFM Kitchen Fan 100 CFM Laundry 50 CFM Bathrooms 50 CFM Bedrooms 10 CFM fresh air Living Areas 10 CFM fresh air Contractor to indicate location of fans if not indicated on plans already. Fastners for Preservative treated wood Fastner for Preservative treated wood shall be of hot dipped zinc-coated galvanized steel, stainless steel, silicon bronze or copper. Exceptions: 1. One-half inch (12.7mm) diameter or greater steel bolts. 2. Fasterners other than nail & timber rivets shall be permitted to be of mechanical deposited zinc coated steel with coating weights in accordance with ASTM B695 class 55 min. Frost Protection 403.1.4.1 Except where otherwise protected from frost, foundation walls, piers and other permanent supports of buildings and structures shall be protected from frost by one or more of the following methods: 1. Extended below the front line specified in Table R301.2 2. Construct in accordance with Section 403.3 3. Construct in accordance with ASCE 32 or 4. Erected on Solid Rock Exceptions: -Protection of freestanding accessory structures with an area of 400 of 600 square feet or less, of light frame construction with an eve height of 10' of less shall not be required. -Decks not supported by a dwelling need not be provided with footings that extend below the frost line. -Footings shall not bear on frozen soil unless the frozen condition is permanent. Ventilation 2015 IRC, Section R408.1, R408.2, and R408.3 The under-floor space between the bottom of the floor joists and the earth under any building (except space occupied by a basement) shall have ventilation openings through foundation walls or exterior walls. The minimum net area of ventilation opening shall not be less than 1 s/f for each 300 s/f of under floor space area, unless the ground surface is covered by a Class 1 vapor retarder material. If the vapor retarder is used the min. net area of ventilation openings shall not be less than 1 s/f for each 1500 s/f. One such vent shall be within 3' of each corner of building. Taped Prep'd for Interior Finishes CM between house, attic, and garage Window Well System: 2015 IRC Code Min. egress window opening will be 5.7 sq. ft 7 Sill height no higher than 44" above FFL Window wells provide a net clear of 9 sq. ft. w/min horiz. projection & width of 36" Exception: Window Wells w/depth greater than 44" will have a permanently affixed ladder or steps. Ladder or Steps 12"-width Inside, 3"-from walls, Spaced no more than 18" O.C. J with 1/2" Sheetrock on Interior Side Taped and Prep'd for Interior Finishes Basement Furring: with 6-Mill Poly Vapor Barrier with (2) 2x4 Top Plates 2x4 Stud Framed @ 24" O.C. with Baring Walls @ 16" O.C. with R-13 Batt Insulation with (1) 2x4 Bottom Plate F 8" Conc. Walls Not Required Not Required #6 at 36" O.C. Not Required Not Required #6 at 35" O.C. #6 at 32" O.C. Max. Wall Height 8' 9' Max. Unbalanced Backfill Height 5' or less 6' 7' 5' or less 6' 7' 8' Concrete Wall Greater than 9' need to have an Architects or Engineers Seal 8' and Under (1) Horizontal Rebar in top 12" and one at mid-height 8'-1" to 9' (1) Horizontal Rebar in top 12" and one bar at each third point Min. Vertical Reiforcement Size & Spacing Table R404.1.2 (3) Reinforced Concrete Foundation Walls GM, GC, SM, SM-SC and ML Soils 45 Cross Section Scale: 1/4"=1'-0" UNO D Size Paper Scale: 1/8"=1'-0" UNO B Size Paper MIN. WIDTHS AND TIE-DOWN FORCES OF ALTERNATE BRACED WALL PANELS Table R602.10.6.1 Seismic Design Category and Windspeed Tie-Down Force (lb.) 8 ft. 2'-4" 9 ft. 2'-8" 10 ft. 2'-8" 11 ft. 3'-2" 12 ft. 3'-6" SDC A,B, and C Windspeed <110 MPH R602.10.6.1, Item 1 R602.10.6.1, Item 2 1800 3000 1800 3000 1800 3000 2000 3300 2200 3600 SDC D,D, and D Windspeed <110 MPH R602.10.6.1, Item 1 R602.10.6.1, Item 2 1800 3000 1800 3000 1800 3000 - - 0 1 2 2'-8"2'-8"2'-8"Note a Note a - - Height of Braced Wall Panel Sheathed Width Sheathed Width 11" Min Run on Conc. Step into house Max Rise 7 3/4" Concrete Steps into House Taped and Prep'd for Interior Finishes over 1/2" Sheetrock on Ceiling Side connected to Rim Joist, spliced using gal. metal ties fastened w/6 16d nails ea. side not less than .058" x 1.5" wide Roof System: 2015 IRC Code Architectural Grade, 25 year Asphalt Shingles over #15 building felt over 7/16" Ext. OSB roof sheeting w/Clips & nailed 6" O.C.-Edges, 10" O.C.-field over 6, 8, & 10:12 Pitch Engineered Trusses @ 24" O.C. (Framed According to Engineered Truss Layout) with R-49 Blown in Attic Insulation with 5/8" Sheet Rock on Interior Side Taped Prep'd for Interior Finishes Contractor to indicate 22"x30" Attic Access Location 2012 IRC Ice Protection Ice Barrier consisting of 2 layers of cemented under-layment and extend from the eave's edge 24" min. from inside exterior wall Taped Prep'd for Interior Finishes Series, Placement, & O.C. Spacing as determined & indicated on TJXpert Layout. (Version 6.0 or later) over 11-7/8 TJI Engineered Floor Joist 3/4" T&G OSB Sub-floor Glued & Nailed 2x4 Stud framed @ 24" O.C. Floor System: 2015 IRC Code with (2) 2x4 Top Plates with (1) 2x4 Bottom Plate with 1/2" Sheetrock Both Sides 2015 IRC Code Interior Walls: 2x6 Fascia Board with 3" Continuous Soffit Venting with add'l 2x4 Support as Required with 3/8" Soffit Sheeting with style "D" Metal Drip Edge 2015 IRC Code Soffit System: A E D B Load-Bearing Value of Soil (psf) 1500 2000 3000 Conventional Light-frame Construction 1-story 2-story 3-story 4" Brick Veneer over light frame 1-story 2-story 3-story 12 21 32 12 16 24 12 12 16 12 12 12 Table R403.1 Min. Width of Conc. or Masonry Footings (inches) Smoke Alarms 2015 IRC Code Section 106. R314 All smoke alarms shall be listed in accordance with UL 217 & installed in accordance with NFPA 72 -One in each sleeping area -Outside of each separate sleeping area in the immediate vicinity of the bedrooms -On each additional story including un-finish & finished basements and habitable attics but not including crawl spaces and uninhabitable attics. In dwellings or dwelling units with splits levels and without an intervening door between the adjacent levels a smoke alarm installed on the upper level shall suffice for the adjacent lower level provided that the lower level is less than one full story below the upper level. -Alarm devices shall be interconnected with battery backup that the acuation of one alarm will activate all of the alarms S Carbon Monoxide Alarms 2015 IRC Section 106 & R315.1 New Construction an approved carbon monoxide alarm installed outside of each sleeping area in the immediate vicinity of bedroom and dwelling units. They shall be listed as complying with UL 2034 and installed accordingly CM with 1/2" Sheetrock on Interior Side Taped and Prep'd for Interior Finishes Basement Furring: with 6-Mill Poly Vapor Barrier with (2) 2x4 Top Plates 2x4 Stud Framed @ 24" O.C. with Baring Walls @ 16" O.C. with R-13 Batt Insulation with (1) 2x4 Bottom Plate F Stair System: 2015 IRC R106, R302.7, 311.7.2, R311.7.5, R311.7.8 Eq. Stair Risers 7 3/4" Max. height Eq. Stair Treads 10" Min. depth over (3) 11.5" MIN. Stair Stringers securely mounted to framing. with Cont. Handrail System mounted 36"above stair plane. with Handrail return to wall. with a Min. 6'-8" Head Clearance above stair plane. with all other Railing System to be min. 42" above FFL & meet current building codes for vert. and horiz. loading. Slate Spacing to no more than 4" sphere to pass thru. 12" Gypsum Board under stairs H 2012 IRC, Section R106 and R308.4.5 7/16" APA OSB & Nailing Pattern 6"-edge 12"-field 2015 IRC Code R106.1 with 1/2" Sheetrock Inside Occupancy separation between Vinyl Siding, Shakes and Faux Stone over Weather Resistive Barrier with (1) 2x6 Bottom Plate with (2) 2x6 Top Plates 2x6 Stud framed @ 24" O.C. UNO Exterior Walls: C Taped Prep'd for Interior Finishes between house, attic, and garage Us e t h i s t a b l e u n l e s s a s o i l t e s t i s d o n e 8" Conc. Walls Not Required Not Required #6 at 36" O.C. Not Required Not Required #6 at 35" O.C. #6 at 32" O.C. Max. Wall Height 8' 9' Max. Unbalanced Backfill Height 5' or less 6' 7' 5' or less 6' 7' 8' Concrete Wall Greater than 9' need to have an Architects or Engineers Seal 8' and Under (1) Horizontal Rebar in top 12" and one at mid-height 8'-1" to 9' (1) Horizontal Rebar in top 12" and one bar at each third point Min. Vertical Reiforcement Size & Spacing Table R404.1.2 (3) Reinforced Concrete Foundation Walls GM, GC, SM, SM-SC and ML Soils 45 Fasten sheathing to header w 8d common or gal. box nails in 3" grid pattern as shown Header to jack-stud strap per table R602.10.6.4 on both sides of opening opposite side of sheathing Min. Length of panel per Table R602.10.5 Min. double 2x4 framing covered w min. 716" thick wood structual panel sheathing w 8d common or gal. box nails at 3" o.c. in framing (studs and sills) as shown. typ. Min. (2) 4200 LB Tie-Down Device (Embedded into Concrete and Nailed into Framing) Min.(1) 5 8" Ø Anchor Bolts R403.1.6 with 2"x2"x316" plate washer Min. Double 2x4 Post Typical Portal Frame Construction If needed, panel splice edges shall occur over & be nailed to common blocking w/in middle 24" of wall mid-height. One row of 3" o.c. nailing is req. in ea. panel edgeMin. 1000LB Tie down Device (H1) Extent of Header Single Portal Frame (One Braced Wall Panel) Extent of Header Double Portal Frame (Two Braced Wall Panels) Ma x H e i g h t 1 0 ' - 0 " Alternate Braced Wall Panel Garage Portal Design PFH Figure R602.10.6.2 Min. 3"x11 14" net header (Steel header prohibited) Ma x T o t a l W a l l H e i g h t 1 2 ' - 0 " Min. reinforcing of foundation, (1) #4 bar top & bottom of footing. Lap bars 15" min. Min. Footing under opening is 12"x12" 2'-18" finished width for single or double portal Pony Wall Height Tension Strap per Table 602.10.6.4 (On opposite side of Sheathing) Fasten Top Plate to header w/2 Rows of 16d sinker nails at 3" O.C. TYP Min. 3 8" Wood Structural Panel Sheating 3' Nailing or Screws 7" O.C. Max Horiz. & Vert. Blocks at Drywall Joints for 7" O.C. Screws of Nails Drywall is shown cutaway Overlapped Double Plate 2x6 Exterior wall @16"O.C. with 7/16" Waferboard Drywall & Waterboard not Shown for clarity 2x4 Interior Wall @16" O.C. 4'x8' Shear Panel on Both Sides 3' 8'x8' Shear Panel on Single Side 48 . 5 " t o c n t r IBWP 3 Interior Braced Wall Panel IBWP 2015 IRC Section 602.10.1 BWP 3-Interior Braced Wall Method 3 (IRC R602.10) 2x4 Studs @ 16" O.C. w/7/16" OSB Nailed 5" O.C. and 10" Field IBWP 5-Interior Braced Wall Method 5 1/2" min. Gypsum board 48" length applied to both sides OR 96" to one side covering 3 studs spaced 16" or 2 studs spaced 24" apart, blocked Screwed @7"/7" w/1" Drywall Screws All Vert Joints occur over stud All Hori. Joints blocked w/2x4 blocking Braced Wall Panel BWP 3' Braced Walls at each strap with 7/16" OSB one side, blocked in all joints Nailed @ 6"/12" w/ 8d or Stapled @ 4"/8" w 16 ga. All joints must occur over raming member 6" at edge 12" in field 4' 8d @ 12" O.C. in field 8d Nails @ 6" O.C. @ edge Braced Wall Panel Detail BWP IBWP 5 All exterior wall are braced walls. 8' - 9 " 6' - 8 " 3' 35 ° 1 5 ' - 1 1 1 / 2 " H Scale: 1/4"=1'-0" H e a d r o o m H e i g h t H a n d r a i l H e i g h t 10 1/2" 7 3 / 8 " 8" 9' 1' - 2 " Stringer Intermediate Support Foundation Wall System: Min. (2) Anchor Bolts per Sill Plate w/nut & Max. 12" from all Corners or Splices with 1/2" Anchor Bolts @ 32" O.C. 10" Long, 7" Embedded SQUARE Plate Washer 3"x3"x1/4" Min. for ea. Bolt over Concrete Foundation Wall Consistant w/2015 IRC Section 608 with Asphalt Emulsion on Exterior Side Consistant w/2015 IRC Section R106.1 over Continuous Concrete Footings over Undisturbed Soil 2x6 Treated Sill Plate over Foam Sill Sealer G Concrete Wall Greater than 9' need to have an Architect or Engineers Seal 8' and Under (1) Horizontal Rebar in top 12" and one at mid-height 8'-1" to 9' (1) Horizontal Rebar in top 12" and one bar at each third point (2) #4 Rebar Horiz. Cont. Entry C G 9' D 12 6 Great Room (2) #4 Rebar Horiz. Cont. 10 ' - 4 " 19 ' - 4 " 29 ' - 6 " A BCovered Entry 30 ' - 2 " (2) #4 Rebar Horiz. Cont. E Mech. Family F 1' - 2 " 9' 20 ' - 6 " 21 ' - 6 " 5" 8' & Under (1) Horiz. Bar in top 12" and one bar at mid-height 8' - 9 1 / 2 " Stair Cavity 10 ' 12 ' Raised Covered Patio A5 Su n d a n c e dr a f t i n g & d e s i g n PAGE LAYOUT A1-Elevations A2-Basement Foundation A3-Floor Plan A4-Bonus Room (Optional) A5-Cross Section A6-Plot Plan GENERAL NOTES: 1/4"=1'-0" UNO Me r i d i a n P l a n Pi n e B r o o k E s t a t e s D2 B 2 L 4 A6 of Sheet R. Blackburn, K. Earl Co p y r i g h t S u n d a n c e D r a f t i n g & D e s i g n 2 0 2 0 Copyright Sundance Drafting and Design 2020 D Size Paper 1/8"=1'-0" UNO B Size Paper Date Scale Drawn By: Reviewed By: Bid Set Permit Set T. Stoddart TOTAL SQ. FTG.= 3880 MAIN FLOOR=1938/1840 INTERIOR BASEMENT =1942/1732 INTERIOR Optional BONUS = 381 GARAGE =1038 20 8 . 5 2 4 . 2 8 8 0 N EE D AH OU S E P LA N . C O M 05-04-19 Sundance Drafting and Design tries to provide the most accurate information for your house design as possible, if design information is not provided correctly Sundance is not liable. Many factors occur in construction during the building process that change the continuity of this drawing. Due to these factors if the plan is not followed or changes occur after the final print has been given, Sundance Drafting and Design is not liable for those items. Read through all pages provided. Review all the notations and labels on each page. Engineering supersedes all drafting notations. Labeling by County or City Inspectors have to be followed. Footing, Foundation, Rebar, and Shear walls are specified and have to be followed. Floor Layouts and Truss Details are separate from these pages but need to be kept together and followed. If any problems with the plans, please notify Sundance Drafting and Design. The undersigned has looked through these pages and agrees that all discussed between Client/Contractor and Sundance Drafting and Design is noted and correct Please Initial Here These Plans follow the 2015 IRC Codes Permitting and Inspections Section 106,107,108, & 109 1. For a permit you will need 2 sets of the following: House plans, Floor Layout, Truss Details, Rescheck, Heat Loss Analysis, and Engineer Stamp (if needed). 2. Review entire set of plans including the above described with owner/contractor. 3. This drawing is drawn by an AutoCad Design Specialist not an Architect. All Details should be looked over and approved by contractor before construction begins. Sundance Drafting and Design is not liable for construction mistakes. 4. This drawing is not to be duplicated without written or verbal consent by Tiffany Stoddart. Copyright Sundance Drafting and Design 2020 06-25-19 Rev. Rev. Rev. 08-19-19 03-10-20 12-07-20Plot Plan Scale: 1/8" =1'-0" D Size Paper Scale: 1/16"=1'-0" B Size Paper Pine Brook Estates Div. No. 2, Block No. 2, Lot No. 4 Rexburg, Idaho N O R T H 1 5 5 . 9 2 ' N 8 9 ° 5 9 ' 4 6 " W 117.51' N 0°10'51" E 167.33' S 0°12'45" E R = 5 0 . 0 0 ' L = 7 8 . 3 8 ' 1 0 4 . 9 3 ' N 8 9 ° 5 9 ' 4 6 " E L i n e o f S e t b a c k Line of Setback Line of Setback L i n e o f S e t b a c k G r e e n s i d e L o o p 44 ' 45 ' - 4 1 / 2 " 13 ' 14'-2"44'-6" 55'-4 1/2"43'-4" 7'28'-2"22' 44'-10" 58'-8" 11 ' 11 ' - 2 " 5' - 1 0 " 9' - 2 " 3' - 4 " 12 ' - 1 0 " 45 ' - 1 " 66 ' 24'4'-2" 1'-4" 1'-6" 57'-2" 88'- 3 1 / 2 " 8 8 ' - 3 1 / 2 " 79'- 9 " 7 8 ' - 1 1 " Location of New Construction Optional RV Pad F e n c e l i n e 1 1 6 L F 13'-6" 6 2 ' - 5 " 44 ' - 6 " 1 2 8 ' - 1 1 / 2 " 68'- 1 1 / 2 " F e n c e l i n e 4 3 7 L F 24'-2" 9' 3' - 8 " 1' 1' 5' 8' - 1 0 " 1'-6" 73' - 6 " 11 ' 11 ' 53 ' 10' 10'55'-4 1/2" PERMIT SET