HomeMy WebLinkAboutUPDATED RES CHECK - 20-00355 - 1142 Greenside Loop - Braden New SFRGenerated by REScheck-Web Software
Compliance Certificate
Project AMS Homes Pine Brook Lot 1
Energy Code:2018 IECC
Location:Rexburg, Idaho
Construction Type:Single-family
Project Type:New Construction
Conditioned Floor Area:1,974 ft2
Glazing Area 18%
Climate Zone:6 (8693 HDD)
Permit Date:
Construction Site:
Rexburg, Idaho 83440
Owner/Agent:
Idaho Falls
Designer/Contractor:
Tiffany Stoddart
Sundance Drafting & Design
3456 E. 17th Street
Suite 285
Ammon, Idaho 83406
208-524-2880
sundancednd@msn.com
Permit Number:
Compliance: Passes using UA trade-off
0.3% Better Than Code Maximum UA:330 Your UA:329
The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules.
It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home.
Compliance:
Envelope Assemblies
Assembly
Gross Area
or
Perimeter
Cavity
R-Value
Cont.
R-Value U-Factor UA
Ceiling: Flat Ceiling or Scissor Truss 1,947 50.0 0.0 0.026 51
Wall: Wood Frame, 16" o.c.2,016 22.0 0.0 0.056 94
Door: Solid Door (under 50% glazing)40 0.200 8
Door 1: Glass Door (over 50% glazing)18 0.280 5
Main Window: Vinyl Frame 196 0.280 55
Window: Vinyl Frame 80 0.280 22
Basement: Solid Concrete or Masonry
Wall height: 8.0'
Depth below grade: 7.0'
Insulation depth: 8.0'
1,748 19.0 0.0 0.045 76
Window: Vinyl Frame 64 0.280 18
Project Title: AMS Homes Pine Brook Lot 1
Data filename:Page 1 of 2
03/09/21Report date:
Name - Title Signature Date
Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other
calculations submitted with the permit application. The proposed building has been designed to meet the 2018 IECC requirements in
REScheck Version : REScheck-Web and to comply with the mandatory requirements listed in the REScheck Inspection Checklist.
Project Title: AMS Homes Pine Brook Lot 1
Data filename:Page 2 of 2
03/09/21Report date: