Loading...
HomeMy WebLinkAboutLot Layout Plan - 20-00886 - Pine Brook Div. 2 Blk 6 Lot 7Plot Plan Scale: 1/16" =1'-0" D Size Paper Scale: 1/32"=1'-0" B Size Paper Pine Brook Estates Div. No. 2, Block No. 6, Lot No.7 Rexburg, Idaho Madison County NORTH A5 Su n d a n c e dr a f t i n g & d e s i g n PAGE LAYOUT A1-Elevations A2-Foundation/Basement Plan A3-Floor Plan A4-Cross Section A5-Plot Plan Sundance Drafting and Design tries to provide the most accurate information for your house design as possible, if design information is not provided correctly Sundance is not liable. Many factors occur in construction during the building process that change the continuity of this drawing. Due to these factors if the plan is not followed or changes occur after the final print has been given, Sundance Drafting and Design is not liable for those items. Read through all pages provided. Review all the notations and labels on each page. Engineering supersedes all drafting notations. Labeling by County or City Inspectors have to be followed. Footing, Foundation, Rebar, and Shear walls are specified and have to be followed. Floor Layouts and Truss Details are separate from these pages but need to be kept together and followed. If any problems with the plans, please notify Sundance Drafting and Design. The undersigned has looked through these pages and agrees that all discussed between Client/Contractor and Sundance Drafting and Design is noted and correct Please Initial Here These Plans follow the 2015 IRC Codes Permitting and Inspections Section 106,107,108, & 109 1. For a permit you will need 2 sets of the following: House plans, Floor Layout, Truss Details, Rescheck, Heat Loss Analysis, and Engineer Stamp (if needed). 2. Review entire set of plans including the above described with owner/contractor. 3. This drawing is drawn by an AutoCad Design Specialist not an Architect. All Details should be looked over and approved by contractor before construction begins. Sundance Drafting and Design is not liable for construction mistakes. 4. This drawing is not to be duplicated without written or verbal consent by Tiffany Stoddart. GENERAL NOTES: 1/4"=1'-0" UNO Co p y r i g h t S u n d a n c e D r a f t i n g & D e s i g n 2 0 2 0 Copyright Sundance Drafting and Design 2020 Copyright Sundance Drafting and Design 2020 1/8"=1'-0" UNO Start Date Permit Set Bid Set TOTAL SQ. FTG.= 4405 MAIN FLOOR=2237/2130 INTERIOR BASEMENT=2180/1962 INTERIOR GARAGE=1038 20 8 . 5 2 4 . 2 8 8 0 N EE D AH OU S E P LA N . C O M Rev Rev A5 of Rev Fa i r e s R e s i d e n c e 11-18-2019 12-17-2019 Location of New Construction 85 ' - 2 " 18.47' S 89° 59' 46" W 18 5 . 6 2 ' N 0 ° 0 ' 1 4 " W 13 0 . 7 3 ' N 3 9 ° 5 5 ' 5 0 " E 9 9 . 9 4 ' S 5 7 ° 2 3 ' 4 5 " E C106 R=200.00' L=113.82' 54.21' N 89° 59' 46" E59.41' N 89° 59' 46" E Line of Required Setback Lin e o f R e q u i r e d S e t b a c k Line of Required Setback Li n e o f R e q u i r e d S e t b a c k 98'-7" 9 8 ' - 7 " 5 4 ' - 8 " 10 7 ' - 3 1 / 2 " 45 ' 7' - 6 " 70'-6" 7'-6" 8 2 ' - 5 " 2 5 ' 4 4 ' - 8 1 / 2 " 28 ' - 6 " 39 ' 28 ' 2' 14 ' - 8 " 32 ' 13 '8' 3' 12 ' - 6 " 3 2 ' - 8 " 13 ' 1'7' 34 ' 24 ' - 8 " 37 ' 2' 6' 5' 13 ' 7' 40 ' - 8 " 34'-7 1/2" 53 ' - 8 1 / 2 " 10 ' 42'-1 1/2"26 ' - 9 " 12.90' N 89° 59' 46" E 06-02-2020 PE R M I T S E T