HomeMy WebLinkAboutTOWER ANALYSIS REPORT - 21-00071 - T-Mobile Cell Tower - Parts ReplacementPowder River Development Services, LLC 408 S. Eagle Road, Suite 200, Eagle ID 83616 Phone: (208) 938-8844 Website: www.powderriverdev.com Tower Analysis Report Date Prepared: 11/4/2020 – Rev. 1 Carrier Data: Site Name: Menan Butte Site Number: SL01482A Site Data: 1095 East Butte Road Sugar City, ID 83434 Powder River Development Services, LLC is pleased to submit this Tower Analysis Report for the proposed site modifications, at the above-referenced site. This structural analysis was performed to address the adequacy of the existing tower to safely support the existing/proposed loading. Based on the governing load case listed within this report, we have determined that the tower structure is: Existing + Proposed Equipment Tower Structurally Adequate (46.6%) Note: See Analysis Criteria for loading configuration Foundation Structurally Adequate This structural review has been performed in accordance with the TIA-222 Standard, ASCE 7, and the International Building Code. These results are based on the existing loads with the proposed loading as listed within this report. Should the design criteria, proposed loading or configuration change, the tower should be re-analyzed based on the new proposed configuration. Based on the attached scope of work the existing tower was analyzed to determine its structural adequacy for the proposed loading. We at Powder River Development Services, LLC appreciate the opportunity to provide engineering services for this project. Please contact us should you have any questions or require any additional information regarding this report. Sincerely, Adam Graban Anthony Tombo, PE, SE, MLSE Engineer Tech Professional Structural Engineer Powder River Development Services, LLC Powder River Development Services, LLC Table of Contents 1.0 Introduction .......................................................................................................................................... 1 1.1 Project Scope: ..................................................................................................................................... 1 1.2 Site Description: .................................................................................................................................. 1 2.0 Analysis Criteria .................................................................................................................................. 1 2.1 Code Compliance: ............................................................................................................................... 1 2.2 Loading and Analysis Criteria: ............................................................................................................. 2 3.0 Analysis Procedure ............................................................................................................................. 3 3.1 Documentation: ................................................................................................................................... 3 3.2 Analysis Method: ................................................................................................................................. 3 3.3 Assumptions: ....................................................................................................................................... 3 4.0 Analysis Results .................................................................................................................................. 4 Appendices Appendix A: Design Info ................................................................................................................................ 5 Appendix B: Analysis Data ............................................................................................................................ 9 SL01482A – Menan Butte Rev. 1 - 11/4/2020 1095 East Butte Road Page 1 Powder River Development Services, LLC 408 S. Eagle Road, Suite 200, Eagle ID 83616 Phone: (208) 938-8844 Website: www.powderriverdev.com 1.0 Introduction 1.1 Project Scope: Powder River Development Services, LLC has performed a Tower Analysis for an existing monopole tower at the above-referenced location. The tower analysis results are provided in the “Analysis Results” section of this report. 1.2 Site Description: The proposed equipment will be mounted to a proposed 14’ Low-profile platform mount [RMQLP-xxx-HK / RMQLP-xxx + PRK1245L + HRK14] on an existing 50’ monopole tower located in Madison County, Idaho. Information for the three proposed sectors was obtained from the documents listed in Section 3. Refer to the loading table in Section 2 for details of the antennas and associated equipment. 2.0 Analysis Criteria 2.1 Code Compliance: The tower was analyzed in conformance with the following criteria: • 2015 International Building Code • ASCE 7 • TIA 222-G Figure 1.1 Site Photograph. Table 2.1 Site Properties Mount Center 50’ Mount Type Proposed 14’ Low-profile platform mount [RMQLP-xxx-HK / RMQLP-xxx + PRK1245L + HRK14] Support Structure 50’ Monopole Tower Exposure Category C Risk Category II Basic Wind Speed 90 mph (TIA 222-G) Wind Speed with Ice 50 mph Ice Thickness 0.25” (TIA 222-G) NOTE: DUE TO ¼” ICE, NO ICE ANALYSIS REQUIRED. SL01482A – Menan Butte Rev. 1 - 11/4/2020 1095 East Butte Road Page 2 Powder River Development Services, LLC 408 S. Eagle Road, Suite 200, Eagle ID 83616 Phone: (208) 938-8844 Website: www.powderriverdev.com 2.2 Loading and Analysis Criteria: The following loading criteria is based on the listed RFDS sheets as listed in Table 3.1. Table below represents the final proposed sector breakdown for all loading by the carrier for this installation. In the event there is conflicting information between the RFDS and the to date photos, assumptions for analysis will be noted below Table 2.2. Table 2.2 Design Appurtenance Loading per Sector Proposed Loading Sector Quantity Elev. (A.G.L.) Model ALPHA SECTOR 1 50 ft RFS – APX17DWV-17DWV-S-E-A20 1 50 ft RFS – APXVAARR24 43-U-NA20 1 50 ft Ericsson AIR6449 B41 1 50 ft Ericsson – 4449 B71/B85 1 50 ft Ericsson – 4415 B66A 1 50 ft Ericsson – 4424 B25 1 50 ft 3’ Dish BETA SECTOR 1 50 ft RFS – APX17DWV-17DWV-S-E-A20 1 50 ft RFS – APXVAARR24 43-U-NA20 1 50 ft Ericsson AIR6449 B41 1 50 ft Ericsson – 4449 B71/B85 1 50 ft Ericsson – 4415 B66A 1 50 ft Ericsson – 4424 B25 GAMMA SECTOR 1 50 ft RFS – APX17DWV-17DWV-S-E-A20 1 50 ft RFS – APXVAARR24 43-U-NA20 1 50 ft Ericsson AIR6449 B41 1 50 ft Ericsson – 4449 B71/B85 1 50 ft Ericsson – 4415 B66A 1 50 ft Ericsson – 4424 B25 Table 2.3 Design Equipment Loading Summary The following loading criteria details the total loading on the tower/structure at given elevations. This information is based on the existing information provided to Powder River Development Services, LLC., that are listed in Table 3.1. Any additional assumptions due to conflicts in existing information and present photos will be noted below Table 2.3. Elev. (A.G.L.) Quan. Model Mount Coax 50’ 3 RFS – APX17DWV-17DWV-S-E-A20 14’ Low-profile platform mount [RMQLP-xxx-HK / RMQLP-xxx + PRK1245L + HRK14] (1) 9x18 HCS (2) 6x12 HCS (1) 6x12 HCS2 3 RFS – APXVAARR24 43-U-NA20 3 Ericsson AIR6449 B41 3 Ericsson – 4449 B71/B85 3 Ericsson – 4415 B66A 3 Ericsson – 4424 B25 1 3’ Dish 39’ 1 2’ Dish n/a 30’ 3 Powerwave 7721 Platform Mount w/ Handrails n/a 6 RV9017 Antenna 3 KMWAMX CS 17-65 3 RRUS 11 3 TMA 22’ 1 3’ Dish n/a NOTE: 1. Proposed equipment are shown in “BOLD-ITALIC” 2. Feedlines to be installed internally SL01482A – Menan Butte Rev. 1 - 11/4/2020 1095 East Butte Road Page 3 Powder River Development Services, LLC 408 S. Eagle Road, Suite 200, Eagle ID 83616 Phone: (208) 938-8844 Website: www.powderriverdev.com 3.0 Analysis Procedure 3.1 Documentation: This tower analysis was performed based on the following information, and written direction from the client regarding the final antenna elevations 3.2 Analysis Method: Mathcad, Microsoft Excel, and TNX Tower, three commercially available computational software packages, were used to analyze a three-dimensional structural model of the tower for the proposed new equipment. Select output from the analysis is included in Appendix B. 3.3 Assumptions: 1) This Structural Analysis is not a condition assessment of the structure nor the anchorage and is only an evaluation of the theoretical structural capacity. 2) This analysis is based from the information supplied, and therefore, this report’s results are as accurate as the supplied data. 3) All member connections are assumed to have been designed to meet or exceed the load carrying capacity of the connected member unless otherwise specified in this report. 4) It is the contractor/carrier/owner’s responsibility to verify that no discrepancies exist between actual field conditions and those assumptions listed herein. 5) The use of this report shall be limited to the above-referenced scope of work and may not be used for any other purposes without the written consent of Powder River Development Services, LLC. 6) Serviceability (antenna twist, tilt, sway, etc.) was not included as part of this analysis. 7) The structure/hardware were properly installed, in accordance with the manufacturer’s specifications and/or industry standards, and has been maintained such that no significant wear, weathering or other structural defects are present that would reduce the structural integrity of the assembly. 8) Steel grades have been assumed as follows: a) Channel, Solid Round, Angle, Plate ASTM A36 (GR 36) b) HSS (Rectangular) ASTM 500 (GR B-46) c) HSS (Round) ASTM 500 (GR B-42) d) Pipe ASTM A53 (GR 35) e) Connection Bolts ASTM A325 f) U-Bolts SAE 429 Gr.2 Table 3.1 Provided Documents Document Prepared By Date Structural Analysis G & A Engineering Services, Inc. 11/18/2015 Structural Analysis Anderson Engineering Company, Inc. 1/24/2018 RFDS Carrier 9/2/2020 Construction Drawings Powder River Development Services, LLC 9/30/2020 SL01482A – Menan Butte Rev. 1 - 11/4/2020 1095 East Butte Road Page 4 Powder River Development Services, LLC 408 S. Eagle Road, Suite 200, Eagle ID 83616 Phone: (208) 938-8844 Website: www.powderriverdev.com 9) Rad centers of antennas are based off centers shown on construction drawings and RFDS. If these heights differ from actual locations, the actual locations should be provided to the engineer for reanalysis. Contractor to field verify this information. 10) Foundation reactions from Sabre Industry Foundation Design dated 7/9/2013 provided in Anderson Engineering Company Analysis dated 1/24/2018 were utilized for comparison to the proposed reactions and considered adequate due to a reduction. This analysis may be affected if any assumptions are not valid or have been made in error. Powder River Development Services, LLC should be notified immediately should any discrepancies between these assumptions and actual field conditions be discovered. 4.0 Analysis Results Table 4.1 below contains the analysis summary for the major structural components (see Appendix B for additional information). Based on the above analysis results, the tower has adequate strength capacity to provide support for the proposed loading as described in this report and criteria listed in Section 2.0. Table 4.1 Structural Component Demand vs. Capacity Structure Structural Component Member Type Capacity % Results Monopole Tower TP35.45x25x0.3125” 41.6% Pass Base Plate SQ PL 2.25” x 39.25” 41.0% Pass Anchor (8) 2.25” DIA. 46.6% Pass Type Original1 Proposed % Utilized Results Moment 1324.17 k-ft 741.82 k-ft 56.0% Adequate Axial 18.37 kip 15.59 kip 84.9% Adequate Shear 35.55 kip 20.27 kip 55.5% Adequate 1) NOTE: 1. Foundation reactions from Sabre Industry Foundation Design dated 7/9/2013 provided in Anderson Engineering Company Analysis dated 1/24/2018 were utilized for comparison to the proposed reactions and considered adequate due to a reduction. SL01482A – Menan Butte Rev. 1 - 11/4/2020 1095 East Butte Road Page 5 Powder River Development Services, LLC 408 S. Eagle Road, Suite 200, Eagle ID 83616 Phone: (208) 938-8844 Website: www.powderriverdev.com Appendix A: Design Info SL01482A – Menan Butte Rev. 1 - 11/4/2020 1095 East Butte Road Page 6 Powder River Development Services, LLC 408 S. Eagle Road, Suite 200, Eagle ID 83616 Phone: (208) 938-8844 Website: www.powderriverdev.com SL01482A – Menan Butte Rev. 1 - 11/4/2020 1095 East Butte Road Page 7 Powder River Development Services, LLC 408 S. Eagle Road, Suite 200, Eagle ID 83616 Phone: (208) 938-8844 Website: www.powderriverdev.com SL01482A – Menan Butte Rev. 1 - 11/4/2020 1095 East Butte Road Page 8 Powder River Development Services, LLC 408 S. Eagle Road, Suite 200, Eagle ID 83616 Phone: (208) 938-8844 Website: www.powderriverdev.com SL01482A – Menan Butte Rev. 1 - 11/4/2020 1095 East Butte Road Page 9 Powder River Development Services, LLC 408 S. Eagle Road, Suite 200, Eagle ID 83616 Phone: (208) 938-8844 Website: www.powderriverdev.com Appendix B: Analysis Data SL01482A – Menan Butte Rev. 1 - 11/4/2020 1095 East Butte Road Page 10 Powder River Development Services, LLC 408 S. Eagle Road, Suite 200, Eagle ID 83616 Phone: (208) 938-8844 Website: www.powderriverdev.com Tower Input Data The tower is a monopole. This tower is designed using the TIA-222-G standard. The following design criteria apply: Tower is located in Madison County, Idaho. Basic wind speed of 90 mph. Structure Class II. Exposure Category C. Topographic Category 3. Crest Height 864.00 ft. Nominal ice thickness of 0.2500 in. Ice thickness is considered to increase with height. Ice density of 56 pcf. A wind speed of 50 mph is used in combination with ice. Temperature drop of 50 °F. Deflections calculated using a wind speed of 60 mph. A non-linear (P-delta) analysis was used. Pressures are calculated at each section. Stress ratio used in pole design is 1. Local bending stresses due to climbing loads, feed line supports, and appurtenance mounts are not considered. Options Consider Moments - Legs Distribute Leg Loads As Uniform Use ASCE 10 X-Brace Ly Rules Consider Moments - Horizontals Assume Legs Pinned Calculate Redundant Bracing Forces Consider Moments - Diagonals √ Assume Rigid Index Plate Ignore Redundant Members in FEA Use Moment Magnification Use Clear Spans For Wind Area SR Leg Bolts Resist Compression √ Use Code Stress Ratios Use Clear Spans For KL/r √ All Leg Panels Have Same Allowable √ Use Code Safety Factors - Guys Retension Guys To Initial Tension Offset Girt At Foundation Escalate Ice √ Bypass Mast Stability Checks √ Consider Feed Line Torque Always Use Max Kz Use Azimuth Dish Coefficients Include Angle Block Shear Check Use Special Wind Profile √ Project Wind Area of Appurt. Use TIA-222-G Bracing Resist. Exemption Include Bolts In Member Capacity Autocalc Torque Arm Areas Use TIA-222-G Tension Splice Exemption Leg Bolts Are At Top Of Section Add IBC .6D+W Combination Poles Secondary Horizontal Braces Leg √ Sort Capacity Reports By Component Include Shear-Torsion Interaction Use Diamond Inner Bracing (4 Sided) √ Triangulate Diamond Inner Bracing Always Use Sub-Critical Flow SR Members Have Cut Ends Treat Feed Line Bundles As Cylinder Use Top Mounted Sockets SR Members Are Concentric Ignore KL/ry For 60 Deg. Angle Legs Pole Without Linear Attachments Pole With Shroud Or No Appurtenances Outside and Inside Corner Radii Are Known Tapered Pole Section Geometry Section Elevation ft Section Length ft Splice Length ft Number of Sides Top Diameter in Bottom Diameter in Wall Thickness in Bend Radius in Pole Grade L1 49.00-0.00 49.00 18 25.0000 35.4500 0.3125 1.2500 A572-65 (65 ksi) Tapered Pole Properties Section Tip Dia. in Area in2 I in4 r in C in I/C in3 J in4 It/Q in2 w in w/t L1 25.3375 24.4869 1885.4965 8.7641 12.7000 148.4643 3773.4740 12.2458 3.8500 12.32 35.9487 34.8520 5436.3445 12.4738 18.0086 301.8749 10879.8423 17.4293 5.6892 18.205 SL01482A – Menan Butte Rev. 1 - 11/4/2020 1095 East Butte Road Page 11 Powder River Development Services, LLC 408 S. Eagle Road, Suite 200, Eagle ID 83616 Phone: (208) 938-8844 Website: www.powderriverdev.com Tower Elevation ft Gusset Area (per face) ft2 Gusset Thickness in Gusset Grade Adjust. Factor Af Adjust. Factor Ar Weight Mult. Double Angle Stitch Bolt Spacing Diagonals in Double Angle Stitch Bolt Spacing Horizontals in Double Angle Stitch Bolt Spacing Redundants in L1 49.00-0.00 1 1 1 Monopole Base Plate Data Base Plate Data Base plate is square √ Base plate is grouted Anchor bolt grade A615-75 Anchor bolt size 2.2500 in Number of bolts 8 Embedment length 73.0000 in f'c 4 ksi Grout space 4.5000 in Base plate grade A572-50 Base plate thickness 2.2500 in Bolt circle diameter 41.5000 in Outer diameter 39.2500 in Inner diameter 23.2500 in Corner clipped 5.0000 in Base plate type Plain Plate Feed Line/Linear Appurtenances - Entered As Area Description Face or Leg Allow Shield Exclude From Torque Calculation Component Type Placement ft Total Number CAAA ft2/ft Weight plf AVA7-50 (1-5/8 LOW DENSI. FOAM) C No No Inside Pole 49.00 - 3.00 12 No Ice 1/2'' Ice 0.00 0.00 0.72 0.72 6x12 HyperFlex C No No Inside Pole 49.00 - 3.00 18 No Ice 1/2'' Ice 0.00 0.00 1.68 1.68 Feed Line/Linear Appurtenances Section Areas Tower Section Tower Elevation ft Face AR ft2 AF ft2 CAAA In Face ft2 CAAA Out Face ft2 Weight K L1 49.00-0.00 A B C 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.00 0.00 1.79 Feed Line/Linear Appurtenances Section Areas - With Ice Tower Section Tower Elevation ft Face or Leg Ice Thickness in AR ft2 AF ft2 CAAA In Face ft2 CAAA Out Face ft2 Weight K L1 49.00-0.00 A B C 0.644 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.000 0.00 0.00 1.79 SL01482A – Menan Butte Rev. 1 - 11/4/2020 1095 East Butte Road Page 12 Powder River Development Services, LLC 408 S. Eagle Road, Suite 200, Eagle ID 83616 Phone: (208) 938-8844 Website: www.powderriverdev.com Feed Line Center of Pressure Section Elevation ft CPX in CPZ in CPX Ice in CPZ Ice in L1 49.00-0.00 0.0000 0.0000 0.0000 0.0000 Note: For pole sections, center of pressure calculations do not consider feed line shielding. Shielding Factor Ka Tower Section Feed Line Record No. Description Feed Line Segment Elev. Ka No Ice Ka Ice Discrete Tower Loads Description Face or Leg Offset Type Offsets: Horz Lateral Vert ft ft ft Azimuth Adjustment ° Placement ft CAAA Front ft2 CAAA Side ft2 Weight K RFS - APX17DWV- 17DWVS-E-A20 A From Face 3.00 -4.00 0.00 0.0000 50.00 No Ice 1/2'' Ice 9.22 9.71 3.26 3.72 0.06 0.10 RFS - APXVAARR24 43-U-NA20 (Octo) A From Face 3.00 -2.00 0.00 0.0000 50.00 No Ice 1/2'' Ice 20.24 20.89 8.89 9.49 0.09 0.20 Ericsson - AIR6449 B41 A From Face 3.00 2.00 0.00 0.0000 50.00 No Ice 1/2'' Ice 5.68 5.98 2.49 2.72 0.10 0.14 Radio 4449 B71 + B85 A From Face 3.00 -4.00 0.00 0.0000 50.00 No Ice 1/2'' Ice 1.97 2.15 1.41 1.57 0.08 0.09 Radio 4415 B66A A From Face 3.00 -2.00 0.00 0.0000 50.00 No Ice 1/2'' Ice 1.86 2.03 0.87 1.00 0.05 0.06 Ericsson - Radio 4424 B25 A From Face 3.00 -2.00 0.00 0.0000 50.00 No Ice 1/2'' Ice 2.05 2.23 1.61 1.77 0.09 0.11 RFS - APX17DWV-17DWVS-E-A20 B From Face 3.00 -4.00 0.00 0.0000 50.00 No Ice 1/2'' Ice 9.22 9.71 3.26 3.72 0.06 0.10 RFS - APXVAARR24 43-U- NA20 (Octo) B From Face 3.00 -2.00 0.00 0.0000 50.00 No Ice 1/2'' Ice 20.24 20.89 8.89 9.49 0.09 0.20 Ericsson - AIR6449 B41 B From Face 3.00 2.00 0.00 0.0000 50.00 No Ice 1/2'' Ice 5.68 5.98 2.49 2.72 0.10 0.14 Radio 4449 B71 + B85 B From Face 3.00 -4.00 0.00 0.0000 50.00 No Ice 1/2'' Ice 1.97 2.15 1.41 1.57 0.08 0.09 Radio 4415 B66A B From Face 3.00 -2.00 0.00 0.0000 50.00 No Ice 1/2'' Ice 1.86 2.03 0.87 1.00 0.05 0.06 Ericsson - Radio 4424 B25 B From Face 3.00 -2.00 0.00 0.0000 50.00 No Ice 1/2'' Ice 2.05 2.23 1.61 1.77 0.09 0.11 RFS - APX17DWV- 17DWVS-E-A20 C From Face 3.00 -4.00 0.00 0.0000 50.00 No Ice 1/2'' Ice 9.22 9.71 3.26 3.72 0.06 0.10 RFS - APXVAARR24 43-U- NA20 (Octo) C From Face 3.00 -2.00 0.00 0.0000 50.00 No Ice 1/2'' Ice 20.24 20.89 8.89 9.49 0.09 0.20 Ericsson - AIR6449 B41 C From Face 3.00 2.00 0.0000 50.00 No Ice 1/2'' Ice 5.68 5.98 2.49 2.72 0.10 0.14 SL01482A – Menan Butte Rev. 1 - 11/4/2020 1095 East Butte Road Page 13 Powder River Development Services, LLC 408 S. Eagle Road, Suite 200, Eagle ID 83616 Phone: (208) 938-8844 Website: www.powderriverdev.com Description Face or Leg Offset Type Offsets: Horz Lateral Vert ft ft ft Azimuth Adjustment ° Placement ft CAAA Front ft2 CAAA Side ft2 Weight K 0.00 Radio 4449 B71 + B85 C From Face 3.00 -4.00 0.00 0.0000 50.00 No Ice 1/2'' Ice 1.97 2.15 1.41 1.57 0.08 0.09 Radio 4415 B66A C From Face 3.00 -2.00 0.00 0.0000 50.00 No Ice 1/2'' Ice 1.86 2.03 0.87 1.00 0.05 0.06 Ericsson - Radio 4424 B25 C From Face 3.00 -2.00 0.00 0.0000 50.00 No Ice 1/2'' Ice 2.05 2.23 1.61 1.77 0.09 0.11 RRUS11 A From Face 2.50 1.00 0.00 0.0000 30.00 No Ice 1/2'' Ice 2.79 3.00 1.19 1.34 0.05 0.07 RRUS11 B From Face 2.50 1.00 0.00 0.0000 30.00 No Ice 1/2'' Ice 2.79 3.00 1.19 1.34 0.05 0.07 RRUS11 C From Face 2.50 1.00 0.00 0.0000 30.00 No Ice 1/2'' Ice 2.79 3.00 1.19 1.34 0.05 0.07 TMA A From Face 2.50 -1.00 0.00 0.0000 30.00 No Ice 1/2'' Ice 3.75 3.99 1.80 1.97 0.05 0.08 TMA B From Face 2.50 -1.00 0.00 0.0000 30.00 No Ice 1/2'' Ice 3.75 3.99 1.80 1.97 0.05 0.08 TMA C From Face 2.50 -1.00 0.00 0.0000 30.00 No Ice 1/2'' Ice 3.75 3.99 1.80 1.97 0.05 0.08 RV9017 Antenna A From Face 2.50 -3.00 0.00 0.0000 30.00 No Ice 1/2'' Ice 5.87 6.32 3.53 3.97 0.03 0.06 RV9017 Antenna B From Face 2.50 -3.00 0.00 0.0000 30.00 No Ice 1/2'' Ice 5.87 6.32 3.53 3.97 0.03 0.06 RV9017 Antenna C From Face 2.50 -3.00 0.00 0.0000 30.00 No Ice 1/2'' Ice 5.87 6.32 3.53 3.97 0.03 0.06 Powerwave 7721 A From Face 2.50 -6.00 0.00 0.0000 30.00 No Ice 1/2'' Ice 9.68 10.16 3.73 4.19 0.04 0.09 Powerwave 7721 B From Face 2.50 -6.00 0.00 0.0000 30.00 No Ice 1/2'' Ice 9.68 10.16 3.73 4.19 0.04 0.09 Powerwave 7721 C From Face 2.50 -6.00 0.00 0.0000 30.00 No Ice 1/2'' Ice 9.68 10.16 3.73 4.19 0.04 0.09 KMW AMX CS 17-65 A From Face 2.50 2.00 0.00 0.0000 30.00 No Ice 1/2'' Ice 0.58 0.68 0.49 0.59 0.06 0.07 KMW AMX CS 17-65 B From Face 2.50 2.00 0.00 0.0000 30.00 No Ice 1/2'' Ice 0.58 0.68 0.49 0.59 0.06 0.07 KMW AMX CS 17-65 C From Face 2.50 2.00 0.00 0.0000 30.00 No Ice 1/2'' Ice 0.58 0.68 0.49 0.59 0.06 0.07 RV9017 Antenna A From Face 2.50 3.00 0.00 0.0000 30.00 No Ice 1/2'' Ice 5.87 6.32 3.53 3.97 0.03 0.06 RV9017 Antenna B From Face 2.50 3.00 0.00 0.0000 30.00 No Ice 1/2'' Ice 5.87 6.32 3.53 3.97 0.03 0.06 RV9017 Antenna C From Face 2.50 3.00 0.0000 30.00 No Ice 1/2'' Ice 5.87 6.32 3.53 3.97 0.03 0.06 SL01482A – Menan Butte Rev. 1 - 11/4/2020 1095 East Butte Road Page 14 Powder River Development Services, LLC 408 S. Eagle Road, Suite 200, Eagle ID 83616 Phone: (208) 938-8844 Website: www.powderriverdev.com Description Face or Leg Offset Type Offsets: Horz Lateral Vert ft ft ft Azimuth Adjustment ° Placement ft CAAA Front ft2 CAAA Side ft2 Weight K 0.00 Platform w/ HR A From Face 2.50 0.00 0.00 0.0000 30.00 No Ice 1/2'' Ice 12.00 12.86 2.00 2.19 0.57 0.63 Platform w/ HR B From Face 2.50 0.00 0.00 0.0000 30.00 No Ice 1/2'' Ice 12.00 12.86 2.00 2.19 0.57 0.63 Platform w/ HR C From Face 2.50 0.00 0.00 0.0000 30.00 No Ice 1/2'' Ice 12.00 12.86 2.00 2.19 0.57 0.63 14' Low Pro-Platform w/ Reinforcement and Handrail A None 0.0000 48.00 No Ice 1/2'' Ice 39.24 48.14 38.48 47.60 2.13 2.58 Dishes Description Face or Leg Dish Type Offset Type Offsets: Horz Lateral Vert ft Azimuth Adjustment ° 3 dB Beam Width ° Elevation ft Outside Diameter ft Aperture Area ft2 Weight K MW Dish 36'' Dia C Paraboloid w/Radome From Face 0.00 0.00 0.00 Worst 22.00 3.00 No Ice 1/2'' Ice 7.07 7.47 0.07 0.11 MW Dish 24'' Dia B Paraboloid w/Radome From Face 0.00 0.00 0.00 Worst 39.00 2.00 No Ice 1/2'' Ice 3.14 3.41 0.10 0.12 MW Dish 36'' Dia B Paraboloid w/Radome From Face 0.00 0.00 0.00 Worst 49.00 3.00 No Ice 1/2'' Ice 7.07 7.47 0.07 0.11 Load Combinations Comb. No. Description 1 Dead Only 2 1.2 Dead+1.6 Wind 0 deg - No Ice 3 0.9 Dead+1.6 Wind 0 deg - No Ice 4 1.2 Dead+1.6 Wind 90 deg - No Ice 5 0.9 Dead+1.6 Wind 90 deg - No Ice 6 1.2 Dead+1.6 Wind 180 deg - No Ice 7 0.9 Dead+1.6 Wind 180 deg - No Ice 8 1.2 Dead+1.0 Ice+1.0 Temp 9 1.2 Dead+1.0 Wind 0 deg+1.0 Ice+1.0 Temp 10 1.2 Dead+1.0 Wind 90 deg+1.0 Ice+1.0 Temp 11 1.2 Dead+1.0 Wind 180 deg+1.0 Ice+1.0 Temp 12 Dead+Wind 0 deg - Service 13 Dead+Wind 90 deg - Service 14 Dead+Wind 180 deg - Service Maximum Member Forces Section No. Elevation ft Component Type Condition Gov. Load Comb. Axial K Major Axis Moment kip-ft Minor Axis Moment kip-ft L1 49 - 0 Pole Max Tension 1 0.00 0.00 0.00 Max. Compression 8 -19.50 -0.27 -0.02 Max. Mx 4 -15.59 -741.82 0.00 Max. My 2 -15.59 -0.20 741.63 SL01482A – Menan Butte Rev. 1 - 11/4/2020 1095 East Butte Road Page 15 Powder River Development Services, LLC 408 S. Eagle Road, Suite 200, Eagle ID 83616 Phone: (208) 938-8844 Website: www.powderriverdev.com Section No. Elevation ft Component Type Condition Gov. Load Comb. Axial K Major Axis Moment kip-ft Minor Axis Moment kip-ft Max. Vy 4 20.28 -741.82 0.00 Max. Vx 2 -20.28 -0.20 741.63 Max. Torque 6 0.66 Maximum Reactions Location Condition Gov. Load Comb. Vertical K Horizontal, X K Horizontal, Z K Pole Max. Vert 8 19.50 0.00 0.00 Max. Hx 14 13.01 0.00 -5.04 Max. Hz 3 11.70 -0.00 20.27 Max. Mx 2 741.63 -0.00 20.27 Max. Mz 4 741.82 -20.27 -0.00 Max. Torsion 6 0.66 -0.00 -20.27 Min. Vert 5 11.70 -20.27 -0.00 Min. Hx 5 11.70 -20.27 -0.00 Min. Hz 7 11.70 -0.00 -20.27 Min. Mx 6 -741.62 -0.00 -20.27 Min. Mz 3 0.15 -0.00 20.27 Min. Torsion 2 -0.66 -0.00 20.27 Tower Mast Reaction Summary Load Combination Vertical K Shearx K Shearz K Overturning Moment, Mx kip-ft Overturning Moment, Mz kip-ft Torque kip-ft Dead Only 13.01 0.00 0.00 -0.00 -0.16 0.00 1.2 Dead+1.6 Wind 0 deg - No Ice 15.61 0.00 -20.27 -741.63 -0.20 0.66 0.9 Dead+1.6 Wind 0 deg - No Ice 11.70 0.00 -20.27 -740.34 -0.15 0.66 1.2 Dead+1.6 Wind 90 deg - No Ice 15.61 20.27 0.00 -0.00 -741.82 0.18 0.9 Dead+1.6 Wind 90 deg - No Ice 11.70 20.27 0.00 -0.00 -740.48 0.18 1.2 Dead+1.6 Wind 180 deg - No Ice 15.61 0.00 20.27 741.62 -0.20 -0.66 0.9 Dead+1.6 Wind 180 deg - No Ice 11.70 0.00 20.27 740.33 -0.15 -0.66 1.2 Dead+1.0 Ice+1.0 Temp 19.50 0.00 0.00 0.02 -0.27 0.00 1.2 Dead+1.0 Wind 0 deg+1.0 Ice+1.0 Temp 19.50 -0.00 -5.32 -184.02 -0.27 0.14 1.2 Dead+1.0 Wind 90 deg+1.0 Ice+1.0 Temp 19.50 5.32 0.00 0.02 -184.31 0.04 1.2 Dead+1.0 Wind 180 deg+1.0 Ice+1.0 Temp 19.50 -0.00 5.32 184.06 -0.27 -0.14 Dead+Wind 0 deg - Service 13.01 -0.00 -5.04 -184.12 -0.16 0.16 Dead+Wind 90 deg - Service 13.01 5.04 0.00 -0.00 -184.28 0.05 Dead+Wind 180 deg - Service 13.01 -0.00 5.04 184.12 -0.16 -0.16 Solution Summary Load Comb. Sum of Applied Forces Sum of Reactions % Error PX K PY K PZ K PX K PY K PZ K 1 0.00 -13.01 0.00 0.00 13.01 0.00 0.000% 2 0.00 -15.61 -20.27 -0.00 15.61 20.27 0.001% 3 0.00 -11.70 -20.27 -0.00 11.70 20.27 0.001% 4 20.27 -15.61 0.00 -20.27 15.61 -0.00 0.001% SL01482A – Menan Butte Rev. 1 - 11/4/2020 1095 East Butte Road Page 16 Powder River Development Services, LLC 408 S. Eagle Road, Suite 200, Eagle ID 83616 Phone: (208) 938-8844 Website: www.powderriverdev.com Load Comb. Sum of Applied Forces Sum of Reactions % Error PX K PY K PZ K PX K PY K PZ K 5 20.27 -11.70 0.00 -20.27 11.70 -0.00 0.001% 6 0.00 -15.61 20.27 -0.00 15.61 -20.27 0.001% 7 0.00 -11.70 20.27 -0.00 11.70 -20.27 0.001% 8 0.00 -19.50 0.00 0.00 19.50 0.00 0.000% 9 0.00 -19.50 -5.32 0.00 19.50 5.32 0.000% 10 5.32 -19.50 0.00 -5.32 19.50 -0.00 0.000% 11 0.00 -19.50 5.32 0.00 19.50 -5.32 0.000% 12 0.00 -13.01 -5.04 0.00 13.01 5.04 0.000% 13 5.04 -13.01 0.00 -5.04 13.01 -0.00 0.000% 14 0.00 -13.01 5.04 0.00 13.01 -5.04 0.000% Non-Linear Convergence Results Load Combination Converged? Number of Cycles Displacement Tolerance Force Tolerance 1 Yes 6 0.00000001 0.00000001 2 Yes 6 0.00000001 0.00010140 3 Yes 6 0.00000001 0.00008176 4 Yes 6 0.00000001 0.00009926 5 Yes 6 0.00000001 0.00008004 6 Yes 6 0.00000001 0.00010138 7 Yes 6 0.00000001 0.00008174 8 Yes 6 0.00000001 0.00000001 9 Yes 6 0.00000001 0.00005174 10 Yes 6 0.00000001 0.00005183 11 Yes 6 0.00000001 0.00005170 12 Yes 6 0.00000001 0.00003979 13 Yes 6 0.00000001 0.00003978 14 Yes 6 0.00000001 0.00003976 Base Plate Design Data Plate Thickness in Number of Anchor Bolts Anchor Bolt Size in Actual Allowable Ratio Bolt Tension K Actual Allowable Ratio Bolt Compression K Actual Allowable Ratio Plate Stress ksi Actual Allowable Ratio Stiffener Stress ksi Controlling Condition Ratio 2.2500 8 2.2500 104.18 223.65 0.47 107.78 371.27 0.29 18.506 45.000 0.41 Bolt T 0.47 Compression Checks Pole Design Data Section No. Elevation ft Size L ft Lu ft Kl/r A in2 Pu K fPn K Ratio Pu fPn L1 49 - 0 (1) TP35.45x25x0.3125 49.00 0.00 0.0 34.8520 -15.59 2508.96 0.006 Pole Bending Design Data Section No. Elevation ft Size Mux kip-ft fMnx kip-ft Ratio Mux fMnx Muy kip-ft fMny kip-ft Ratio Muy fMny L1 49 - 0 (1) TP35.45x25x0.3125 741.82 1810.97 0.410 0.00 1810.97 0.000 SL01482A – Menan Butte Rev. 1 - 11/4/2020 1095 East Butte Road Page 17 Powder River Development Services, LLC 408 S. Eagle Road, Suite 200, Eagle ID 83616 Phone: (208) 938-8844 Website: www.powderriverdev.com Section No. Elevation ft Size Mux kip-ft fMnx kip-ft Ratio Mux fMnx Muy kip-ft fMny kip-ft Ratio Muy fMny Pole Shear Design Data Section No. Elevation ft Size Actual Vu K fVn K Ratio Vu fVn Actual Tu kip-ft fTn kip-ft Ratio Tu fTn L1 49 - 0 (1) TP35.45x25x0.3125 20.28 1254.48 0.016 0.18 3631.23 0.000 Pole Interaction Design Data Section No. Elevation ft Ratio Pu fPn Ratio Mux fMnx Ratio Muy fMny Ratio Vu fVn Ratio Tu fTn Comb. Stress Ratio Allow. Stress Ratio Criteria L1 49 - 0 (1) 0.006 0.410 0.000 0.016 0.000 0.416 1.000 4.8.2 Section Capacity Table Section No. Elevation ft Component Type Size Critical Element P K øPallow K % Capacity Pass Fail L1 49 - 0 Pole TP35.45x25x0.3125 1 -15.59 2508.96 41.6 Pass Summary Pole (L1) 41.6 Pass Base Plate 46.6 Pass RATING = 46.6 Pass SL01482A – Menan Butte Rev. 1 - 11/4/2020 1095 East Butte Road Page 18 Powder River Development Services, LLC 408 S. Eagle Road, Suite 200, Eagle ID 83616 Phone: (208) 938-8844 Website: www.powderriverdev.com Existing Information SL01482A – Menan Butte Rev. 1 - 11/4/2020 1095 East Butte Road Page 19 Powder River Development Services, LLC 408 S. Eagle Road, Suite 200, Eagle ID 83616 Phone: (208) 938-8844 Website: www.powderriverdev.com