ORDINANCE 1240
ADOPTION OF 2018 INTERNATIONAL BUILDING AND FIRE CODES
AN ORDINANCE OF THE CITY OF REXBURG, A POLITICAL SUBDIVISION OF THE
STATE OF IDAHO, AMENDING THE 2018 VERSION OF THE INTERNATIONAL
ENERGY CONSERVATION CODE; ADOPTING THE 2018 INTERNATIONAL
BUILDING CODE; 2018 INTERNATIONAL EXISTING BUILDING CODE; 2018
INTERNATIONAL RESIDENTIAL CODE; 2017 IDAHO STATE (UNIFORM)
PLUMBING CODE OR DIVISION OF BUILDING SAFETY CURRENTLY ADOPTED
EDITION; 2018 IECC WITH 2018 AMENDMENTS FOR RESIDENTIAL PORTION;
REPEAL ORDINANCE 1109 AND ADOPTING THE 2018 INTERNATIONAL FIRE
CODE INCLUDING STATE FIRE MARSHALL AMENDMENTS; 2017 NATIONAL
ELECTRICAL CODE OR DIVISION OF BUILDING SAFETY CURRENTLY ADOPTED
EDITION; 2018 INTERNATIONAL MECHANICAL CODE OR DIVISION OF BUILDING
SAFETY CURRENTLY ADOPTED EDITION AS AMENDED; AND REPEAL
ORDINANCE 1108 AND ORDINANCE 1059 OF CITY OF REXBURG; PROVIDING FOR
SEVERABILITY; REPEALING CONFLICTING ORDINANCES AND PROVIDING AN
EFFECTIVE DATE
NOW THEREFORE, be it ordained by the Council of City of Rexburg, in the State of
Idaho, as follows:
SECTION 1: AMENDMEM "TITLE 15 BUILDINGS REGULATIONS" of the
Rexburg Municipal Code is hereby amended as follows:
AMENDMENT
Title 15 Building Regulations
SECTION 2: AMENDMEIff "15.01.010 Uniform Building Code Adopted By
Reference - Copies On File" of the Rexburg Municipal Code is hereby amended as follows:
AMENDMENT
15.01.010 Uniform Building Code Adopted and the National Fire Protection Association (NFPA) By
Reference - Copies On File
That certain documents, three (3) copies of each code of which are on file in the office of the City of
Rexburg, Community Development Department of the City of Rexburg, being marked and designated
as the International Building Code 2018 edition as amended, the International Existing Building Code
2018 edition as amended; the 2018 International Residential Code; 2017 Idaho State (uniform)
Plumbing Code or Division of Building Safety currently adopted edition; 2018 International Energy
Conservation Code (IECC) with 2018 IECC amendments for Residential portion; Repeal Ordinance
1109 by adopting the 2018 International Fire Code including State Fire Marshall amendments; 2017
National Electrical Code (effective July 1, 2017) or Division of Building Safety currently adopted
edition; 2018 International Mechanical Code or Division of Building Safety currently adopted edition
as amended. All published by the International Code Council and the National Fire Protection
Association (NFPA) are hereby adupled as the Building Code of the Citv of Rexburg, in the State
of Idaho for regulating and governing the conditions and maintenance of all property, buildings and
structures; by providing the standards for supplied utilities and facilities and other physical things and
conditions essential to ensure that structures are safe, sanitary and fit for occupation and use; and the
condemnation of buildings and structures unfit for human occupancy and use and the demolition of
such structures as herein provided: proving for the issuance of permits and collection of fees therefore;
and each and all of the regulations, provisions, penalties, conditions and term of said Building Codes
on file in the office of the City of Rexburg Building Department are hereby referred to adopted and
made a part hereof as if fully set out in this ordinance, with the additions, insertions and deletions and
changes, if any, prescribed in 15.01.020 through 15.01.070 and Chapter 15.07 of this ordinance. (Ord.
1059 § 1, 2010).
SECTION 3: ADOPTION "15.01.015 Code Adoption' of the Rexburg Municipal
Code is hereby added as follows:
ADOPTION
15.01.015 Code Adoption(Added)
That the editions of the following recognized codes as currently adopted by the State of Idaho as the
official building codes of the City of Rexburg, including amendments and revisions as set forth in the
IDAPA 24.39.30, by the Idaho Building Code Board of the Division of Building Safety as authorized
and provided in 15.01.020. through 15.01.070 and 15.07 The adopted versions of the foregoing codes
shall be effective January 1, 2021. The foregoing codes shall be deemed superseded by successive
versions of such codes as they are adopted or approved by the State of Idaho effective on the 1st day
of January the year following the date any such codes are made effective for the state, unless a
different date is required by state statute.
I. 2018 International Building Code
2. 2018 International Existing Building Code
3. 2018 International Residential Code
4. 2017 Idaho State (Uniform) Plumbing Code or Division of Building Safety currently adopted
edition
5. 2018 IECC with 2012 amendments for Residential portion
6. 2018 Idaho Fire Code including State Fire Marshall amendments
7. 2017 National Electrical Code (NFPA) or Division of Building Safety currently adopted
edition
8. 2018 International Mechanical Code or Division of Building Safety currently adopted edition
SECTION 4: REPEAL "15.01.020 Amendments" of the Rexburg Municipal Code
is hereby i-epealed as follows:
REPEAL
� c n i n�
n�:�0 Am,:ndjn--t is (Repealed)
1. Amendments to, Adopted Codes: The following sections are hereby revised as set forth in the
IDAPA 07 Fide 031, Chapter 01 by, the Idaho Building Code Board of the Division of
Building Safety, as authorized under Section 394107, Idaho Code: (See.Attachment A)
IDAPA 07, Title 03, Chapter 01.
2. 2012 IRC Edition with the following amendments:
a. Include appendix "F" as adopted to include the radon requirements.
i. Radon Control Methods: Radon is found in significant quantities in most of
the Rexburg City limits. Areas on the hill do not test high and as such, radon
mitigation is not required.
ii In the rest of the city, radon mitigation is required as per Appendix F of the
International Residential Code. The City allows an exception to the
mitigation by testing, out on a case by case basis. (Ord. 1174§3, 2010.)
SECTION 5: ADOPTION "15.01.020 Amendments To Adopted Building Code" of
the Rexburg Municipal Code is hereby added as follows:
ADOPTION
15.01.020 Amendments To Adopted Building Code(Added)
State of Idaho (IDAPA 24.39.30) 2018 International Building Code Amendments
The following section is hereby revised/amended as set forth in the IDAPA 24.39.30. by the Idaho
Building Code Board of the Division of Building Safety as authorized:
1. Any reference to Sections 101.4 concerning Electrical and 101.4.3 Plumbing shall be deleted,
thus solely regulated under the State of Idaho IC 54-1001 and IC 54-2601.
2. Delete Section 1608.2 and replace with the following: 1608.2 Ground snow loads. The
ground snow load to be used is 50 lb.
3. All Appendices with the exception of Annendix B of the IBC. 2018 Edition, are hereby
deleted.
4. Delete Section 305.2.3 and replace with the following: 305.2.3 Twelve (12) or fewer children
in a dwelling unit. A facility such as the above within a dwelling unit and having twelve (12)
or fewer children receiving such day care shall be classified as a Group R-3 occupancy or
shall comply with the International Residential Code. (3-20-20)T
5. Delete Section 303.2.4 and replace with the following: 308.2.4 Five (5) or fewer persons
receiving custodial care. A facility with five (5) or fewer persons receiving custodial care shall
be classified as a Group R.3 occupancy or shall comply with the International Residential
Code. (3-20-20)T
6. Delete Section 308.3.2 and replace with the following: 308.3.2 Five (5) or fewer persons
receiving medical care. A facility with five (5) or fewer persons receiving medical care shall
be classified as a Group R-3 occupancy. (3-20-20)T
7. Delete Section 308.5.4 and replace with the following: 308.5.4 Persons receiving care in a
dwelling unit. A facility such as the above within a dwelling unit and having twelve (12) or
fewer children receiving day care or having five (5) or fewer persons receiving custodial care
shall be classified as a Group R-3 occupancy or shall comply with the International
Residential Code. (3-20-20)T
8. Delete Section 310.4 and replace with the following: 310.4 Residential Group R-3.
Residential Group R-3 occupancies where the occupants are primarily permanent in nature
and not classified as Group R-1, R-2, R-4, E or I, including:
a. Buildings that do not contain more than two (2) dwelling units.
b. Care facilities that provide accommodations for five (5) or fewer persons receiving
personal care, custodial care or medical care.
c. Congregate living facilities (nontransient) with sixteen (16) or fewer occupant,
including boarding houses (nontransient), convents, dormitories, fraternities and
sororities, and monasteries.
d. Congregate living facilities (transient) with ten (10) or fewer occupants, including
boarding houses (transient).
e. Dwelling units providing day care for twelve (12) or fewer children.
f. Lodging houses (transient) With five (5) or fewer guest rooms and ten (10) or fewer
occupants, (3-20-20)T
9. Delete Section 310.4.1 and replace with the following: 310.4.1 Care facilities within a
dwelling, Care facilities for twelve (12) or fewer children receiving day care or for five (5) or
fewer persons receiving personal care or custodial care that are within a one- or two-family
dwelling are permitted to comply with the international Residential Code. (3-20-20)T
10. Delete footnote a under Table 2902.1 Minimum Number of Required Plumbing Fixtures and
replace with the following: a For business occupancies excluding restaurants and mercantile
occupancies with an occupant load of thirty (30) or fewer; service sinks shall not be required.
(3-20-20)T
11. Delete footnote f from Table 2902.1 Minimum Number of required Plumbing Fixtures, add
footnote f in the header row of the column in Table 2902.1 labeled "Drinking Fountains," and
delete footnote f under Table 2902.1 and replace with the following: f Drinking fountains are
not required for an occupant load of thirty (3 0) or fewer. (3-20-20)T
12. Delete Section 3113.1 and replace with the following: 3113.1 General. The provisions of this
Section shall apply to relocatable buildings. Relocatable buildings manufactured after the
effective date of this code shall comply with the applicable provisions of this code; title 39,
chapter 43, Idaho Code; and IDAPA 24.39.31. Exception: This Section shall not apply to
manufactured housing used as dwellings. (3-20- 20)T
City of Rexburg 2018 International Building Code Amendments
Delete Section 903.2.8 and replace with the following:
903.2.8 Group R. An automatic sprinkler system installed in accordance with Section 903.3 shall be
provided throughout all buildings with a Group R fire area. Exceptions:
1. All single family homes and multiple family dwellings up to two (2) units that are physically
separated by ten (10) feet or more of space, to the nearest building, are hereby exempted
from the provisions of the International Fire Code, the International Building Code and the
Idaho Residential Code that require such dwellings to have automatic fire sprinkler systems
installed. Nothing in this section shall prevent any person from voluntarily installing an
automatic fire sprinkler system in any residential dwelling.
Section 1805 -Footings and Foundations: The below prescriptive format to be employed in the
Jurisdiction, only with the permission of the Building Official after review of the site specific. The
Prescriptive method will be used in place of the Tables referenced in Code Sections 1809 -Concrete
Footings (Table 1809.7) and 1807 -Foundation Walls (Tables 1807.1.6.2 through 1807.1.6.3(3)) Add
Prescriptive alternative: Prescriptive Method of Footing and Foundation Walls in The City of
Rexburg:
1. Concrete footings constructed in the jurisdiction shall have a minimum steel reinforcement
consisting of at least 2ea. #4 horizontal reinforcing bars placed continuously along the footing
and located a minimum of 3 inches from the bottom and sides of the footings (see table
1809.7 for footing width and thickness ONLY). Steel reinforcement shall be securely
positioned by hanging wire ties, concrete blocks, or other approved methods that will hold the
reinforcing steel securely in place during the concrete placement.
2. Foundation walls 4 feet or less in height shall have a minimum nominal concrete wall
thickness of 6 inches and shall have a minimum steel reinforcement consisting of not less than
one #4 horizontal bar located in the upper six inches of the wall. The remaining height of the
foundation wall shall have horizontal #4 bars spaced evenly at a distance of no greater than 24
inches between bars.
3. Foundation walls constructed in the jurisdiction supporting more than four feet of unbalanced
backfill, shall have a minimum nominal concrete thickness of 8 inches, and shall have a
minimum steel reinforcement consisting of not less than two #4 horizontal bars located in the
upper 12 inches of the wall. The remaining height of the wall shall have horizontal #4 bars
equally spaced at a distance no greater than 24 inches between bars.
4. Foundation walls constructed within this jurisdiction shall have a minimum vertical steel
reinforcement consisting of "L" -shaped #4 vertical bars spaced at a horizontal distance from
one another no greater than 48 inches between bars if the wall is 48 inches or less in height,
and shall have 24 inch horizontal spacing between bars if the wall is higher than 48 inches.
The short horizontal portion of the "L" -shaped #4 bars shall be at least 6 inches in length, and
shall be approximately centered (vertically) in the concrete footing. Concrete shall be tamped
around the "L" -shaped portion of the vertical steel placed in the footing, so that the steel is
firmly encased in the footing concrete. If additional re -bar is added to the vertical portion of
the #4 "L" -shaped bar to gain additional height, the lap shall be at least 15 inches in length. all
steel shall have a minimum concrete cover of 3 inches when the wall is poured against earth,
and 2 inches cover when pored against air (formed free-standing) or against adjacent wall
materials. Wall reinforcing steel shall be wire -tied together to prevent movement or
displacement of the steel during the concrete placement.
SECTION 6: ADOPTION "15.01.030 Amendments To Adopted Residential Code"
of the Rexburg Municipal Code is hereby added as follows:
ADOPTION
15.01.030 Amendments To Adopted Residential Code(Added)
State of Idaho (IDAPA 24.30.39) 2018 International Residential Code Amendments
1. Delete the exception under Section 8101.2 Scope, and replace with the following"
Exception: The following shall also be permitted to be constructed in accordance with
this code:
a. Owner -occupied lodging houses with five (5) or fewer guestrooms and ten (10) or
fewer total occupants.
b. A care facility with five (5) or fewer persons receiving custodial care within a
dwelling unit or single-family dwelling.
c. A care facility for five (5) or fewer persons receiving personal care that are within
a dwelling unit or single-family dwelling.
d. A care facility with twelve (12) or fewer children receiving day care within a
dwelling unit or single-family dwelling. (3-20-20)T
2. Delete Section R104.10.1 Flood hazard areas. (3-20-20)T
3. Delete item number 7 under the "Building" subheading of Section R105.2 Work exempt
from permit, and replace with the following: 7. Prefabricated swimming pools that are
not greater than four (4) feet (one thousand, two hundred nineteen (1219) mm) deep. (3-
24-24)T
4. Add the following as item number 11 under the "Building" subheading of Section
R105.2 Work exempt from permit: 11. Flag poles. (3-20-20)T
5. Delete Section R109.1.3 and replace with the following: R109.1.3 Floodplain inspections.
For construction in areas prone to Flooding as established by Table R301.2(1), upon
placement of the lowest floor, including basement, the building official is authorized to
require submission of documentation of the elevation of the lowest floor, including
basement, required in Section R322. (3-20-20)T
6. Delete Section 8301.2.1.2 Protection of Openings.
7. Delete Table R302.1(1) and replace with the following:
TABLE R302.1(1) - EXTERIOR WALLS
EXTERIOR WAIL ELEMENT
MINIMUM FIRE -RESISTANCE
MINIMUM FIRE
SEPARATION
RATING
DISTANCE
1 hour -tested in accordance
with ASTM E 118, UL263, or
Fae-resistance rated
Section 703.3 of the International
< 3 feet
Walls
Building Code with exposure
from both sides
Not fire -resistance rated
0 hours
a 3 feet
MINIMUM FIRE -RESISTANCE
MINIMUM FIRE
EXTERIOR WALL ELEMENT
RATING
SEPARATION
DISTANCE
1 hour on the underside. or
Fire -resistance rated
heavy timber, or fire
z 2 feat to < 3 feet
Projections
retardant -treated wood"-"
Not fine-msistance rated
0 hours
L� 3 feet
Openings
Not allowed
N/A
< 3 feet
in
25% maximum of wall area
0 hours
t 3 feet to < 5 feet
Walls
Unlimited
0 hours
5 feet
Comply vor+th Section R302.4
< 3 feet
Penetrations
All
None required
>_ 3 feet
8. Delete Section R302.12 Fire protection of floors. (3-20-20)T
9. Delete Section R303.4 and replace with the following: R303.4 Mechanical Ventilation.
Dwelling units shall be provided with whole -house mechanical ventilation in accordance
with Section M1505.4. (3-20-20)T
10. Delete the exception under Section R313.1 Townhouse automatic fire sprinkler systems,
and replace with the following: Exception: Automatic residential fire sprinkler systems
shall not be required in townhouses where either two (2) one (1)- hour fire -resistance -
rated walls or a common two (2) -hour fire -resistance rated walls, as specified in item
number 2 of Section R302.2.2 is installed between dwelling units or when additions or
alterations are made to existing townhouses that do not have an automatic residential fire
sprinkler system installed. (3-20-20)T
11. Delete Section R313.2 One- and two-family dwellings automatic fire sprinkler systems.
(3-20-20)T
12. Delete the exceptions under Section R314.2.2 Alterations, repairs and additions, and
replace with the following: Exceptions:
a. Work involving the exterior surfaces of dwellings, such as, but not limited to,
replacement of roofing or siding, or the addition or replacement of windows or
doors, or the addition of a porch or deck or electrical permits, are exempt from
the requirements of this section.
b. Installation, alteration or repairs of plumbing or mechanical systems are exempt
from the requirements of this section. (3-20-20)T
13. Delete the exceptions under Section 8315.2.2 Alterations, repairs and additions, and
replace with the following: Exceptions:
a. Work involving the exterior surfaces of dwellings, such as, but not limited to,
replacement of roofing or siding, or the addition or replacement of window or
doors, or the addition of a porch or deck or electrical permits, are exempt from
the requirements of this section.
b. Installation, alteration or repairs of non -combustion plumbing or mechanical
systems are exempt from the requirements of this section. (3-20-20)T
14. Delete Section R322.1.10 As -built elevation documentation. (3-20-20)T
15. Delete Section R322.2.1 and replace with the following: R322.2.1 Elevation
requirements.
a. Buildings and structures in flood hazard areas, including flood hazard areas
designated as Coastal A Zones, shall have the lowest floors elevated to or above
the base flood elevation.
b. In areas of shallow flooding (AO Zones), buildings and structures shall have the
lowest floors (including basement) elevated to a height above the highest adjacent
grade of not less than the depth number specified in feet (mm) on the FIRM, or
not Iess than two (2) feet (610 mm) if a depth number is not specified.
c. Basement floors that are below grade on all sides shall be elevated to or above
base flood elevation. Exception: Enclosed areas below the design flood elevation,
including basements with floors that are not below grade on all sides, shall meet
the requirements of Section R322.2.2. (3-20-20)T
16. Delete subparagraph 2.1 of Section R322.2.2 Enclosed area below design flood elevation,
and replace with the following: 2.1. The total net area of all openings shall be at least one
(1) square inch (645 mm2) for each square foot (0.093 m2) of enclosed area, or the
opening shall be designed and the construction documents shall include a statement that
the design and installation of the openings will provide for equalization of hydrostatic
flood force on exterior walls by allowing the automatic entry and exit of floodwaters. (3-
20-20)T
17. Delete Tables R403 Minimum Depth (D) and Width (W) pf Crushed Stone Footings
(inches), R403.1(1) Minimum Width and Thickness for Concrete Footings for Light -
Frame Construction (inches), R403.1(2) Minimum Width and Thickness for Concrete
Footings for Light -Frame Construction and Brick Veneer (inches), and 8403.1(3)
Minimum Width and Thickness for Concrete Footings with Cast -In -Place or Fully
Grouted Masonry Wall Construction (inches). (3-20-20)T
18. Add the following as Table R403.1:
Add the following as Table R403.1 -
TABLE R403.1
MINIMUM UIDTH OF CONCRETE, PRECASL OR 11I.1,SONRY FOOTINGS (inches)'
For SI: 1 inch= 25.4 mm, 1 pound per square foot = 0.0479 kPa. a Where minimum
footing width is twelve (12) inches, use of a single wythe of solid or fully grouted twelve
(12) -inch nominal concrete masonry units is permitted. (3-20-20)T
19. Delete Section R403.1.1 and replace with the following: R403.1.1 Minimum size.
Minimum sizes for concrete and masonry footings shall be as set forth in Table R403.1
and Figure R403.1(1). The footing width (W) shall be based on the load bearing value of
the soil in accordance with Table R401.4.1. Spread footings shall be at least six (6) inches
in thickness (T). Footing projections (P) shah be at least two (2) inches and shall not
exceed the thickness of the footing. The size of footings supporting piers and columns
shall be based on the tributary load and allowable soil pressure in accordance with Table
R401.4.1. Footings for wood foundations shall be in accordance with the details set forth
in Section R403.2 and Figures R403.1(2) and R403.1(3).(3 -20-20)T
20. Delete Section R602.10 and replace with the following: R602.10 Wall bracing. Buildings
shall be braced in accordance with this Section or, when applicable Section R602.12, or
the most current edition of APA System Report SR -102 as an alternate method. Where a
building, or portion thereof, does not comply with one (1) or more of the bracing
requirements in this Section, those portions shall be designed and constructed in
accordance with Section R301.1. (3-20-20)T
21. Amend Section 403.1.3.1 -Foundations with Stem Walls by insertion of the following
prescriptive methodology: The below prescriptive format to be employed in the
Jurisdiction, only with the permission of the Building Official after review of the site
specific by the building official. Concrete footings constructed in the jurisdiction shall
have a minimum steel reinforcement consisting of at least 2ea.##4 horizontal reinforcing
bars placed continuously along the footing and located a minimum of 3 inches from the
bottom and sides of the footings (see table R404.1.1(1) through R404.1.1(4) for footing
width and thickness ONLY). Steel reinforcement shall be securely positioned by hanging
wire ties, concrete blocks, or other approved methods that will hold the reinforcing steel
LOAD-BEARING VALUE OF SOIL (pst)
1,600
1 2,000 I 3,000 I
Z 4,000
Conventional Ilghtdrame construction
1 -story
12
12 12
12
2 -Story
15
12 12
12
3 -Story
23
17 12
12
44nch brick veneer over tight frame or 8 -Inch hollow concrete masonry
1 -Story
12
12 12
12
2 -Story
21
16 12
12
3 -Story
32
24 16
12
S -Inch solid or fully grouted masonry
1 -Story
16
12 12
12
2 -Story
29
21 14
12
3 -Story
42
32 21
16
For SI: 1 inch= 25.4 mm, 1 pound per square foot = 0.0479 kPa. a Where minimum
footing width is twelve (12) inches, use of a single wythe of solid or fully grouted twelve
(12) -inch nominal concrete masonry units is permitted. (3-20-20)T
19. Delete Section R403.1.1 and replace with the following: R403.1.1 Minimum size.
Minimum sizes for concrete and masonry footings shall be as set forth in Table R403.1
and Figure R403.1(1). The footing width (W) shall be based on the load bearing value of
the soil in accordance with Table R401.4.1. Spread footings shall be at least six (6) inches
in thickness (T). Footing projections (P) shah be at least two (2) inches and shall not
exceed the thickness of the footing. The size of footings supporting piers and columns
shall be based on the tributary load and allowable soil pressure in accordance with Table
R401.4.1. Footings for wood foundations shall be in accordance with the details set forth
in Section R403.2 and Figures R403.1(2) and R403.1(3).(3 -20-20)T
20. Delete Section R602.10 and replace with the following: R602.10 Wall bracing. Buildings
shall be braced in accordance with this Section or, when applicable Section R602.12, or
the most current edition of APA System Report SR -102 as an alternate method. Where a
building, or portion thereof, does not comply with one (1) or more of the bracing
requirements in this Section, those portions shall be designed and constructed in
accordance with Section R301.1. (3-20-20)T
21. Amend Section 403.1.3.1 -Foundations with Stem Walls by insertion of the following
prescriptive methodology: The below prescriptive format to be employed in the
Jurisdiction, only with the permission of the Building Official after review of the site
specific by the building official. Concrete footings constructed in the jurisdiction shall
have a minimum steel reinforcement consisting of at least 2ea.##4 horizontal reinforcing
bars placed continuously along the footing and located a minimum of 3 inches from the
bottom and sides of the footings (see table R404.1.1(1) through R404.1.1(4) for footing
width and thickness ONLY). Steel reinforcement shall be securely positioned by hanging
wire ties, concrete blocks, or other approved methods that will hold the reinforcing steel
securely in place during the concrete placement. Foundation walls 4 feet or less in height
shall have a minimum nominal concrete wall thickness of 6 inches and shall have a
minimum steel reinforcement consisting of not less than one #4 horizontal bar located in
the upper six inches of the wall. The remaining height of the foundation wall shall have
horizontal #4 bars spaced evenly at a distance of no greater than 24 inches between bars.
Foundation walls constructed in the jurisdiction supporting more than four feet of
unbalanced backfill, shall have a minimum nominal concrete thickness of 8 inches, and
shall have a minimum steel reinforcement consisting of not less than two #4 horizontal
bars located in the upper 12 inches of the wall. The remaining height of the wall shall
have horizontal #4 bars equally spaced at a distance no greater than 24 inches between
bars. Foundation walls constructed within this jurisdiction shall have a minimum vertical
steel reinforcement consisting of "L" -shaped #4 vertical bars spaced at a horizontal
distance from one another no greater than 48 inches between bars if the wall is 48 inches
or less in height, and shall have 24 inch horizontal spacing between bars if the wall is
higher than 48 inches. The short horizontal portion of the "L" -shaped #4 bars shall be at
least 6 inches in length, and shall be approximately centered (vertically) in the concrete
footing. Concrete shall be tamped around the "L" -shaped portion of the vertical steel
placed in the footing, so that the steel is firmly encased in the footing concrete. If
additional re -bar is added to the vertical portion of the #4 "L" -shaped bar to gain
additional height, the lap shall be at least 15 inches in length. Wall steel shall have a
minimum concrete cover of 3 inches when the wall is poured against earth, and 2 inches
cover when pored against air (formed free-standing) or against adjacent wall materials.
Wall reinforcing steel shall be wire -tied together to prevent movement or displacement of
the steel during the concrete placement. Agricultural Buildings - Non-commercial
Agricultural buildings, (As Defined by Appendix C -C101.1) with the review and
approval of the City Building Official, and further subject to any surface water and
environmental authorities, MAY be exempt from this code upon approval of application
for such exemption
City of Rexburg 2018 International Residential Code Amendments
Table R301.2(1) of the International Residential Code, 2018 Edition, shall be amended to
read as follows:
TABLE R301.2(1) CLIMATIC AND GEOGRAPHIC DESIGN CRITERIA
Table R301.2 (1) The following listed values are herewith adopted as the minimum
design criteria to be used when designing or constructing any structures falling under
the purview of this ordinance:
NAME
Ground Snow Load
Minimum Wind Design Speed
Topographic Effects
Special Wind Region (Air Freezing Index)
Wmdbourne Debris Zone
Seismic Design Category
Subject To Damage From Weathering
Frost Line Depth (Final Grade to bottom of footing minimum)
Termite
Winter Design Temperature
Ice Barrier Underlayment Required
F1oodHazards HazardsbeamendedHazardsAdoptedJune 3
JuneAdopted3, 1991
Air Freezing Index
Minimum Roof Snow Load
Mean Annual Temperature
DESIGNSnowCRITERIA
Tabel
VALUE
50 lb
90 mph
No
2500
No
D-0
Severe
3b inches
Slight to Moderate
(Rexburg) -5�F
Yes
NVG 1991 FIRM Map
2500
35 #/sq.ft
43.5°F
SECTION 7: 4DOPTION "15.01.040 Amendments To Adopted Energy
Conservation Code" of the Rexburg Municipal Code is hereby added as follows:
ADOPTION
15.01.040 Amendments To Adopted Energy Conservation Code(Added)
State of Idaho (IDAPA 2439.30) 2418 International Energy Conservation Code Amendments
1. Add the following as Section C101.5.2: C101.5.2 Industrial, electronic, and manufacturing
equipment. Buildings or portions thereof that are heated or cooled exclusively to maintain the
required operating temperature of industrial, electronic, or manufacturing equipment shall be
exempt from the provisions of this code. Such buildings or portions thereof shall be separated
from connected conditioned space by building thermal envelope assemblies complying with
this code. (3-20-20)T
2. Add the following as an exception under Section C402.5 Air leakage -thermal envelope
(Mandatory): Exception: For buildings having over fifty thousand (50,000) square feet of
conditioned floor area, air leakage testing shall be permitted to be conducted on less than the
whole building, provided the following portions of the building are tested and their measured
air leakage is area -weighted by the surface areas of the building envelope:
a. The entire floor area of all stories that have any spaces directly under a roof.
b. The entire floor area of all stories that have a building entrance or loading dock.
c. Representative above -grade wall sections of the building totaling at least twenty-five
percent (25%) of the above -grade wall area enclosing the remaining conditioned space.
Floor area tested under subparagraphs l or 2 of this exception shall not be included in
the twenty-five percent (25%) of above -grade wall sections tested under this
subparagraph. (3-20-20)T
3. Add the following as exception number 7 under Section C403.5 Economizers (Prescriptive): 7.
Unusual outdoor air contaminate conditions - Systems where special outside air filtration and
treatment for the reduction and treatment of unusual outdoor contaminants, makes an air
economizer infeasible. (3-20-20)T
4. Delete Table C404.5.I and replace with the following:
TABLE C404.6.1
PIPING VOLUME AND [MAXIMUM PIPING LF-NGT14S
NOMINAL VOLUME MAXIMUM PIPING LENGTH (feet)
PIPE SIZE (liquid ounces
(inches) per foot length) Public lavatory faucets Oftr fixturos
and appliances
114 033 3t 50
5/16 0.5 N/A- non-standard size 50
3/8 0.75 17 50
112 1.5 t0 43
TABLE C404.8.1
PIPING VOLUME AND MAXIMUM PIPING LENGTHS
NOMINAL VOLUME MAXIMUM PIPING LENGTH (feet)
PIPE Btm Q)quld ounces
(Inches) par foot longth) Public lavatory faucets Other fiutums
and appliances
518 2 7 32
314 3 5 21
7/8 4 NIA - non-standard size 18
1 5 3 13
1 114 8 2 8
1 1/2 11 1 6
2 or Wger 18 1 4
For 5I: I inch a 25.4 mm; 1 foot = 304.8 mm; I liquid ounce = 0.030 L; I gallon - 128 ounces. (3-20-20)T
5. Delete the rows in Table R402.1.2 for climate zones "5 and Marine 4" and "6" and replace
with the following:
TABLE PA02.1.2
INSULATION AMD FENESTRATION REQU11WN ENT$ BY COMPONENT °
Wood Slab
Climate Fenestration Skylight° Qlasod Coding Frame, Mass Wall Row Ba Wan rtt` Ft -Value C� wall co
ma
Zone U -Factor U-ractor FSnee.9QtrCabtloa R -Value Walt R-Vatuo3 R -Value R -Value a R-Vahlo
R -Value DoW
5 0.32 0.55 NR 38 10 or
13117 309 151 t9 10. 2 n 15119
S 030 0.55 NR 49 22 of Iwo 30 15(19 10.4 I1 15119
13.20.20)T
6. Add the following as footnote k to the title of Table R402.1.2 - Insulation and Fenestration
Requirements by Component: k For residential log home building thermal envelope
construction requriements see Section R402.6. (3-20-20)T
7. Delete the rows in Table 8402.1.4 for climate zones "5 and Marine 4" and "6" and replace
with the following:
TABLE R40LIA
EQUIVALENT U -FACTORS °
Cltmate Fenestration Skyftght Ceiling Frame Wap Maes Waft Floor Basement Crawtspaco
Zono U4actor U4actor U4actor 1.1 -factor Wactor2i Udactor wall wap
U4actor U -tactor
0.32 0.55 0.030 0.060 0.082 0.033 0.050 0.055
0.30 055 0.028 0.057 0.060 0.033 0.050 0.055
03.20-201T
8. Delete Section R402.4.1 and replace with the following: R402.4.1 Building thermal envelope.
a. Until June 30, 2021, the building thermal envelope shall comply with Sections
R402.4.1.1 (Installation) and either Section R402.4.1.2 (Testing) or Section
R402.4.1.3 (Visual inspection).
b. Effective July 1, 2021, the building thermal envelope of a minimum of twenty percent
(20%) of all new single-family homes constructed by each builder shall comply with
Section R402.4.1.1 (Installation) and Section R402.4.1.2 (Testing). The authority
having jurisdiction may: 2.1. Determine how to enforce this requirement, starting with
the fifth house and continuing with each subsequent fifth house. 2.2 Waive this
requirement if significant testing indicates the five (5) air changes per hour (ACH)
requirement is consistently being met or exceeded (Resulting in a lower ACH). 2.3
Grant exceptions to this requirement in rural areas where testing equipment is not
available or cost effective.
c. Effective July 1, 2021, the building thermal envelope of eighty percent (80%) of all
new single-family homes constructed by each builder shall comply with Section
R402.4.1.1 (Installation) and either Section R402.4.1.2 (Testing) or Section
R402.4.1.3 (Visual inspection ).
d. The sealing methods between dissimilar materials shall allow for differential expansion
and contraction. (3-20-20)T
9. Delete Section R402.4.1.1 and replace with the following: R402.4.1.1 Installation. The
components of the building thermal envelope as listed in Table 8402.4.1.1 shall be installed in
accordance with the manufacturer's instructions and the criteria listed in Table R402.4.1.1, as
applicable to the method of construction. (3-20-20)T
10. Add the following as Section R402.4.1.3: R402.4.1.3 Visual inspection. Building envelope
tightness and insulation installation shall be considered acceptable when the items listed in
Table R402.4.1.1, applicable to the method of construction, are field verified. Where required
by code official in approved party independent form the installer of the insulation shall inspect
the air barrier and insulation. (3-20-20)T
11. Add the following as Section R402.6: R402.6 Residential log home thermal envelope.
Residential log home construction shall comply with Section R401 (General), Section R402.4
(Air leakage), Section R402.5 (Maximum fenestration U -factor and SHGC), Section R403.1
(Controls), the mandatory sections of Sections R403.3 through R403.9, Section 8404
(Electrical Power and Lighting Systems). and either 1., 2., or 3. as follows: 1. Sections R402.2
through R402.3, Section R403.3.1 (Insulation), Section 8404.1 (Lightning equipment) and
Table R402.6 (Log Home Prescriptive Thermal Envelope Requirements by Component). 2.
Section R405 (Simulated Performance Alternative). 3. REScheck (US Department of Energy
Building Codes Program).
12. Add the following as Table R402.6:
TABLE R402.6
LOG HOME PRESCRIPTIVE THERMAL ENVELOPE REQUIREMENTS BY COMPONENT
For SI t toot 304 B mm
Ula gieb CrBvN
Cflmato ? Fonoatratlon Skylight mod Calling{� A� Floor Ora R-vacuo Spaao
Zone u4actoe 114actar F BNQC Dn R-value 1 Sirs to Log R-valuo visa a 4 R b Waa
t�Hva septa R-vacuo4
15.6 - Hign i
e�trpment 032 060 NR 49 5 30 15119 10, 4 ft_ 10113
ppthc
S 4 032 0.60 NR 49 8 l ]0 10113 1 10, 2 R 10/13
6 _11111 0.30 0.60 NR 49 1 8 l �30 } 15J19~ 10, 4 tT 10/13
°The fenestravon U-factor column exdudes skylghts. The SHGC column applies to all glazed fenasvat cn.
°R-5 "ll bo added to the mgw%rW Slab odge R.vatues tar hoatgd slabs
4W% AF UE natural gas or propane. 84Po AFU E ad. or 15 SEER heat pump hoa" equipment (zenal etecfic resistance
testing equipment such as electric Mase b*atd elaWic roststaroe haattng equipment as ft sale soar m for heaung to con-
oidared comp5ant oath ft "h atficlescy cqulpmant path).
4'15/19" means R-15 contrnuoua insulated sheathing an the tnteriof or extanor of the home at R-19 cav4y (rtsuwon at the
mtenor of the basemant wa3 '15119' shall bo permitted to be met with R-13 cavey insutatron on the snterror of the baubr&M
wail ptuz R-5 continuous instutated sheathing on tho ctt9rtor or extenar o1 the hone '10113* moans R-10 ooMMAUS gnaw
Wed sheathing on the tntenor or extencr of the home or R-13 cavity insulation at the intenor of the basement wall.
(3-20.20)T
13. Delete Section R403.5.3 and replace with the following: R403.5.3 Hot water pipe insulation
(Prescriptive). Insulation for hot water piping with a thermal resistance, R -value, of not less
than R-3 shall be applied to the following:
a. Piping serving more than one (l) dwelling unit.
b. Piping located outside the conditioned space.
c. Piping located under a floor slab.
d. Buried piping.
e. Supply and return piping in recirculation systems other than demand recirculation
systems.
14. Delete Section R404.1 and replace with the following: R404.1 Lighting equipment
(Mandatory). A minimum of seventy-five percent (75%) of the lamps in permanently installed
lighting fixtures shall be high -efficacy lamps or a minimum of seventy-five percent (75%) of
the permanently installed lighting fixtures shall contain only high efficacy lamps.
15. Delete Section R406.3 and replace with the following: R406.3 Energy Rating Index. The
Energy Rating Index (ERI) shall be determined in accordance with RESNETIICC 301. Energy
used to recharge or refiiel a vehicle used for transportation on roads that are not on the Uuildung
site shall not be included in the ERI reference design or the rated design. (3-20-20)T
16. Delete Table R406.4 and replace with the following:
Table R406.4 - %taximum Energy Rating Inde
Climate Zone Enorgy Rating Index'
5 1 68
6 ! 68
Miere on-site rrnewablc cnewv is inducted !or compliance using the FRI analysis of Section R406-4, the building
shall meet the rttandatory requirements o; Section R06 2, and the building thennal envelope shall be greater than or
equal to tic levels of ettictertcy and SHGC in 1'abla R.102 1 2 or Table R-102. 1.4 of iltc 2015 International Energ)
Conservation Cotte. (3-20-20)'1'
City of Rexburg 2018 International Energy Conservation Code Amendments
1. An exception to Section R403.3.5 shall be added as follows: Exception: Building -framing
cavities used as ducts or plenums shall comply with Section MI601.1.1 (IRC).
SECTION 8: ADOPTION "15.01.050 Amendments To Adopted Mechanical Code"
of the Rexburg Municipal Code is hereby added as follows:
ADOPTION
15.01.050 Amendments To Adopted Mechanical Code(Added)
City of Rexburg 2018 International Mechanical Code Amendments
1. Section 103.2 of the International Mechanical Code 2015 2018 Edition, shall be amended to
read as follows: 103.2 Appointment. The Code Official shall be appointed by the chief-
appointing
hiefappointing authority of the jurisdiction.
2. Section 109.1 of the International Mechanical Code, 2015 2018 Edition, shall be amended to
read as follows: 109.1 Application for appeal. A person shall have the right to appeal a
decision of the code official to the board of appeals. An application for appeal shall be based
on a claim that the true intent of this code or the rules legally adopted thereunder have been
incorrectly interpreted. The application shall be filed on a form obtained from the code official
within twenty (20) days after the notice was served.
SECTION 9: ADOPTION "15.01.060 Amendments To Adopted Fuel Gas Code" of
the Rexburg Municipal Code is hereby added as follows:
ADOPTION
15.01.060 Amendments To Adopted Fuel Gas Code(Added)
City of Rexburg 2018 International Fuel Gas Code Amendments
1. Section 103.2 of the International Fuel Gas Code, 2018 Edition, shall be amended to read as
follows: 103.2 Appointment. The code official shall be appointed by the chief appointing
authority of the jurisdiction.
2. Section 109.1 of the International Fuel Gas Code, 2018 Edition, shall be amended to read as
follows: 109.1 Application for appeal. A person shall have the right to appeal a decision of the
code official to the board of appeals. An application for appeal shall be based on a claim that
the true intent of this code or the rules legally adopted thereunder, have been incorrectly
interpreted. The application shall be filed on a form obtained from the code official within
twenty (20) days after the notice was served.
SECTION 10: ADOPTION "15.01.070 Amendments To Adopted Plumbing Code"
of the Rexburg Municipal Code is hereby added as follows:
ADOPTION
15.01.070 Amendments To Adopted Plumbing Code(Added)
State of Idaho (IDAPA 07.02.06.16) 2017 Idaho Plumbing Code Amendments
1. IDAPA Rule 07.02.06.011.16 shall be deleted and replaced with the following language: Pot
sinks, scullery sinks, and dishwashing sinks, silverware sinks, commercial dishwashing
machines, silverware -washing machines, and other similar fixtures shall be connected directly
to the drainage system. A floor drain shall be provided adjacent to the fixture, and the fixture
shall be connected on the sewer side of the floor drain trap, provided that no other drainage
line is connected between the floor drain waste connection and the fixture drain. The fixture
and floor drain shall be trapped and vented as required by this Code.
a. IDAPA Rule 07.02.06.011.20 shall be deleted and replaced with the following
language: Food preparation sinks, pot sinks, scullery sinks, dishwashing sinks,
silverware sinks, commercial dishwashing machines, silverware -washing machines,
steam kettles, potato peelers, ice cream dipper wells, and other similar equipment and
fixtures must be indirectly connected to the drainage system by means of an air gap.
The piping from the equipment to the receptor must not be smaller than the drain on
the unit, but it must not be smaller than one (1) inch (twenty-five and four tenths
(25.4) mm).
City of Rexburg 2017 Idaho State Plumbing Code Amendments
1. Chapter 1, Administration. Chapter 1 of the Idaho State Plumbing Code is hereby deleted and
replaced with Chapter 1 of the International Building Code, (2012 Edition).
2. Chapter 3, General Regulations. 313.12.4 Shall be deleted.
3. 422.1 shall be amended to read as follows: "Plumbing fixtures shall be provided for the type
of building occupancy and in the minimum number shown in Chapter 29 of the City's
currently adopted International Building Code, (2018 Edition)."
4. Chapter 6, Water Supply and Distribution. 608.5(7) shall be amended to read as follows:
"Discharge from a relief valve into a water heater pan shall be allowed, provided that the pan
connection and its drain piping are sized at least one (1) pipe size larger than the outlet of the
relief valve."
5. Chapter 10, Traps and Interceptors. Table 10-1 shall be amended to change the footnote that is
indicated by an asterisk to read as follows: "The trap arm lengths of water closets or similar
fixtures which depend upon self -siphoning and re -filling of their traps for proper operation
shall be unlimited."
SECTION 11: AMENDMENT "CHAPTER 15.5 GAS INSTALLATIONS" of the
Rexburg Municipal Code is hereby amended as follows:
AMENDMENT
Chapter 15.5 Fuel Gas (Ifgc) Installations
SECTION 12: AMENDMENT "CHAPTER 15.07 INTERNATIONAL FIRE
CODE" of the Rexburg Municipal Code is hereby amended as follows:
AMENDMENT
CHAPTER 15.07 INTERNATIONAL FIRE CODE
Note to Chapter 15.7: Prior ordinance history: Ords. 654, 672, 689, 718, 784, 828, 873, 918, 933,
997, 1042, 1063, 1096, and 1109. Ord. 1109 is repealed by Ordinance 1240
SECTION 13: AMENDMENT "15.07.010 International Fire Code 2012" of the
Rexburg Municipal Code is hereby amended as follows:
AMENDMENT
15.07.010 International Fire Code 2012
Adopting 2018 International Fire Code and repealing previously adopted 2012 International Fire
Code by reference Ord 1109 §2, 2014.
SECTION 14: RENUMBER "15.07.104.6 Official Records" of the Rexburg
Municipal Code is hereby renumbered as follows:
RENUMBER
15.07.104.6 Official Records
15.07.020 Official Records 104.6
SECTION 15: 64MEND E "15.07.105.1.1 Permits Required" of the Rexburg
Municipal Code is hereby amended as follows:
AMENDMENT
15.07.030 Permits Required 105. 1.1
Permits required by this code shall be obtained from the City of Rexburg Building Department. Permit
fees are located here and shall be paid prior to issuance of the permit_ Issued permits shall be kept on
the premises designated therein at all times and shall be readily available for inspection by the fire
code official. (Ord. 1109 §3(C), 2014).
SECTION 16: RENUMBER, "15.07.105.7.1 Automatic Fire -Extinguishing
Systems." of the Rexburg Municipal Code is hereby renumbered as follows:
RENUMBER
15.07.105.7. LAutomatic Fire-Extinggisbine Svstems.
15.07.040 Automatic Fire -Extinguishing Systems 7.1105.
SECTION 17: RENUMBER, "15.07.105.7.5 Fire Alarm And Detection Systems
And Related Equipment" of the Rexburg Municipal Code is hereby renumbered as follows:
RENUMBER
15.07.105.7.5 Fire A lane And Detection Svstems And. Related Eauinment
15.07.050 Fire Alarm And Detection Systems And Related Equipment 105.7.5
SECTION 18: RENUNWJER "15.07.105.7.6 Fire Pumps And Related Equipment"
of the Rexburg Municipal Code is hereby renumbered as follows:
RENUMBER
15.07.105.7.6 Fire Pugns And Related Eat
15.07.060 Fire Pumps And Related Equipment 105.7.6
SECTION 19: RENUMBER "15.07.106.5 Re -Inspection Fees" of the Rexburg
Municipal Code is hereby renumbered as follows:
RENUMBER
15.07.106.5 Re-Insnection Fees
15.07.070 Re -Inspection Fees 106.5
SECTION 20: ADOPTION "15.07.080 Tags 107.1.1" of the Rexburg Municipal
Code is hereby added as follows:
ADOPTION
15.07.080 Tags 107.1.1(Added)
Tags for maintenance of fire suppression systems, fire extinguishers, and fire alarm systems are
required to be obtained from the Community Development Department for use in the City of
Rexburg.
SECTION 21: RENUMBER "15.07.109.3 Violation Penalties" of the Rexburg
Municipal Code is hereby renumbered as follows:
RENUMBER
15.07.109.3 Violation Penalties
15.07.090 Violation Penalties 109.3
SECTION 22: ADOPTION "15.07.100 Failure To Apply 111.4" of the Rexburg
Municipal Code is hereby added as follows:
ADOPTION
15.07. 100 Failure To Apply 111.4(4dded)
Delete entire 111.4 Failure to apply section.
SECTION 23: AMENDMENT "15.07.113.2 Schedule Of Permit Fees" of the
Rexburg Municipal Code is hereby amended as follows:
AMENDMENT
15.07.113.2 Schedule Of Permit Fees
A fee for each permit and repeated nuisance alarms shall be paid as required, in accordance with the
Rexburg Master Fee List; It can be found here (Ord. 1109 §3(K), 2014).
SECTION 24: RENUMBER "15.07.113.3 Work Commencing Before Permit
Issuance" of the Rexburg Municipal Code is hereby renumbered as follows:
RENUMBER
15.07.113.3 Work Commencing Before Permit Issuance
15.07.120 Work Commencing Before Permit Issuance 113.3
SECTION 25: RENUMBER "15.07.113.6 Reimbursement Of Operational Costs"
of the Rexburg Municipal Code is hereby renumbered as follows:
RENUMBER
15.07.113.6 Reimbursement Of Operational Costs
15.07.130 Reimbursement Of Operational Costs 113.6
SECTION 26: AMENDMENT "15.07.114 Safety System Certification Pemrit" of
the Rexburg Municipal Code is hereby amended as follows:
AMENDMENT
15.07.114 Safety System Certification Permit
All installations, modifications, required maintenance, or servicing of life -safety systems are to be
performed by an approved licensed business or person(s). A business or person(s) shall obtain a
"Safety System Certification Permit" from the Community Development Department to do any work
in the City of Rexburg. Permits shall expire one year from the date of issuance unless otherwise noted
on the permit. Fire AIarm Contractors shall provide proof of Liability Insurance and proof of having a
minimum of a NICET Level III certification for fire alarm systems design and NICET Level I for
testing and startup. Certifications shall be equal to/or the equivalent as specified in NFPA 72.
Fire Sprinkler Contractors shall provide proof of Liability Insurance and proof of having a minimum
of a NICET Level III certification for sprinkler system design, NICET Level I for testing, and any
additional certifications as required. Certifications shall be equal to/or the equivalent as specified in
NFPA 72 (Ord. 1109 §3(N), 2014)
SECTION 27: RENUMBER "15.07.401.3.4 Silencing Fire Alarms" of the Rexburg
Municipal Code is hereby renumbered as follows:
RENUMBER
15.07.401.3.4 Silencing Fire Alarms
15.07.150 Silencing Fire Alarms 401.3.4
SECTION 28: RENUMBER "15.07.401.5 Making False Report" of the Rexburg
Municipal Code is hereby renumbered as follows:
RENUMBER
15.07.401.5 Makine False Renorl
15.07.1 b0 Making False Report 401.5
SECTION 29: ADOPTION "15.07.170 Construction Documents 501.3" of the
Rexburg Municipal Code is hereby added as follows:
ADOPTION
15.07.170 Construction Documents 501.3(Added)
Construction documents for proposed driveways, fire apparatus access, location of fire lanes, security
gates across fire apparatus access and construction documents and hydraulic calculations for fire
hydrant systems shall be submitted the fire department for review and approval prior to construction.
SECTION 30: RENUMBER "15.07.501.4 Timing Of Installation" of the Rexburg
Municipal Code is hereby renumbered as follows:
RENUMBER
15.07.501.4 Timine Of Installation
15.07.180 Timing Of Installation 501.4
SECTION 31: AMENDMENT "15.07.502.1 Driveway" of the Rexburg Municipal
Code is hereby amended as follows:
AMENDMENT
15.07.190 Added Definitions 502.1
Driveway: a vehicular ingress and egress route that serves no more than five (5) single family
dwellings, not including accessory structures (Ord. 1109 § 3(T), 2014).
Fire Station: A building or portion of a building that provides, at a minimum, all weather protection for
fire apparatus. Temperatures inside the building used for this purpose must be maintained at above
thirty-two (32) degrees Fahrenheit.
Fire Station: A building or portion of a building that provides, at a minimum, all weather protection for
fire apparatus. Temperatures inside the building used for this purpose must be maintained at above
thirty-two (32) degrees Fahrenheit.
SECTION 32: AMENDME2U "15.07.503 Fire Apparatus Access Roads And
Driveways" of the Rexburg Municipal Code is hereby amended as follows:
AMENDMENT
15.07.503 Fire Roads And Driveways
Approved fire apparatus access roads shall be provided for every facility, building or portion of a
building hereafter constructed or move into or within the jurisdiction. The fire apparatus access road
shall comply with the requirements of this section and shall extend to within 150 feet of all portions of
the facility and all portions of the exterior walls of the first story of the building as measured by an
approved route around the exterior of the building or facility. Driveways shall be provided and
maintained in accordance with Sections 503.7 through 503.11
SECTION 33: RENUMBER "15.07.503.2.4 Turning Radius" of the Rexburg
Municipal Code is hereby renumbered as follows:
RENUMBER
1.5.[17.503.2.4 Turning Radius
15.07.2 10 Turning Radius 503.2.4
SECTION 34: RENUMBER "15.07.503.4 Obstruction Of Fire Apparatus Access
Roads" of the Rexburg Municipal Code is hereby renumbered as follows:
RENUMBER
15.07.503.4 Obstruction Of Fire Apparatus Access Road.5
15.07.220 Obstruction Of Fire Apparatus Access Roads 503.4
SECTION 35: AMENDMENT "15.07.503.7 Driveways" of the Rexburg Municipal
Code is hereby amended as follows:
AMENDMENT
15.07.230 Specifications 503.2
Driveways shall be provided when any portion of an exterior wall of the first story of a building is
located more than 150 feet from a fire apparatus access road. Driveways shall provide a minimum
unobstructed width of 12 feet and minimum unobstructed height of 13 feet b inches. Driveways in
excess of 150 feet in length shall be provided with turnarounds. Driveways in excess of 200 feet in
length and 20 feet in width may require turnouts in addition to a turnaround (Ord. 1109 §3(Y), 2014).
For more information on driveway specifications, see the City of Rexburg currently adopted
International Fire Code sections 503.2.1 through 503.2.8.
SECTION 36: RENUMBER "15.07.503.7.4 Bridge Load Limits" of the Rexburg
Municipal Code is hereby renumbered as follows:
RENUMBER
15,07,5Q3.7.4 BridLye Load Limits
15.07.240 Bridge Load Limits 503.2.6.1
SECTION 37: RENUMBE$ "15.07.503.7.5 Address Markers" of the Rexburg
Municipal Code is hereby renumbered as follows:
RENUMBER
15.07.503.7.5 Address Markeq
15.07.250 Address Identification 505.1
SECTION 38: RENUMBER "15.07.503.8 Barricade Specifications" of the Rexburg
Municipal Code is hereby renumbered as follows:
RENUMBER
15.07.503.8 Barricade Spgcifications
15.07.260 Barricade Specifications 503.5.2
SECTION 39: ADOPTION "15.07.270 Security Gates 503.7.7" of the Rexburg
Municipal Code is hereby added as follows:
ADOPTION
15.07.270 Security Gates 503.7.7(Added)
Where security gates are installed, they shall have an approved means of emergency operation. The
security gates and emergency operation shall be maintained operational at all times.
SECTION 40: AMENDMENT "15.07.505.3 Multi -Family Dwelling Address" of
the Rexburg Municipal Code is hereby amended as follows:
AMENDMENT
15.07.505.3 Multi -Family Dwelling Address
1. When individual apartment, condominium, or town house structures within a common
complex are designated with separate addresses, individual unit numbers shall be assigned so
there is no duplication of unit designations within a building. The fust floor shall be 100
series, second floor 200 series and so on for each successive floor. Basements shall be 10
series if the next higher floor is designated the first floor, or basements shall be designated 100
series if the next level is called the second floor.
2. When apartment, condominium, or town house complexes (more than one structure) have
been assigned one address, each individual building shall also be assigned a number. The
building number shall be posted in a conspicuous location with the number being a minimum
of twelve (12) inches in height in a contrasting color to the background. Unit or apartment
numbers shall then be assigned in the 10, I00, 200, 300, etc. series per floor as identified in
paragraph a. of this section (Ord. 1109 §3(Q), 2014).
SECTION 41: AMENDMENT "15.07.506.1 Knox Box Location" of the Rexburg
Municipal Code is hereby amended as follows:
AMENDMENT
15.07.506.1 Knox Box Location
Where access to or within a structure or an area is restricted because of secured openings or where
immediate access is necessary for life-saving or fire -fighting purposes, the fire code official is
authorized to require a Knox Box® (s) to be installed in approved locations. The Knox Box®(s) shall
contain keys, cards, or codes to gain necessary access and operate life safety equipment as required by
the fire code official. All newly constructed structures subject to this section shall have the Knox
Box®(s) installed and containing the required keys prior to the issuance of an occupancy permit.
Locations shall include:
1. Commercial, industrial, or educational structures protected by an automatic alarm system or
automatic suppression system, or such structures that are secured in a manner that restricts
access during an emergency;
2. Multi -family residential structures that have restricted access through locked doors and have a
common corridor for access to the dwelling units;
3. Governmental structures and nursing care facilities;
4. Buildings and structures with 20,000 square feet or more shall have a minimum of two (2)
Knox Box®(s).
SECTION 42: AMENDMENT "15.07 507.2 Type Of Water Supply" of the
Rexburg Municipal Code is hereby amended as follows:
AMENDMENT
15.07 507.2 Type Of Water Supply
A water supply shall consist of water delivered by fire apparatus, reservoirs, pressure tanks, elevated
tanks, water mains, or other sources capable of providing the required fire flow as approved by the fire
code official. No exceptions allowed. Water supply shall consist of water delivered by fire apparatus,
reservoirs, pressure tanks, elevated tanks, water mains or other sources approved by the fire code
official capable of providing the required fire flow.
SECTION 43: ADOPTIOht "15.07.310 Water Service Connections 507.3" of the
Rexburg Municipal Code is hereby added as follows:
ADOPTION
15.07.3 10 Water Service Connections 507.3 (Added)
All water service connections that are metered in a building or structure shall have a valve located
outside of the building or structure for shutting off service in the case of an emergency. The valve shall
be installed in an approved location at the time of construction. if the water service connection
supplies the fire suppression system and the valve is located outside of the city right-of-way, the valve
shall be installed adjacent to the fire lane. The valve shall be a monitored post indicator valve, or a
similar valve that is acceptable to the Fire Code Official.
SECTION 44: AMENDMENT "15.07.507.5 Fire Hydrant Systems" of the Rexburg
Municipal Code is hereby amended as follows:
AMENDMENT
15.07.507.5 Fire Hydrant Systems
Fire hydrant systems shall comply with sections 507.5.1 through 507.5.8.
SECTION 45: ADOPTION "15.07.330 Pipe Hashed Parking Spaces 507.5.4" of the
Rexburg Municipal Code is hereby added as follows:
ADOPTION
15.07.330 Pipe Hashed Parking Spaces 507.5.4(Added)
Pipe hashed parking spaces shall be 5 feet (51) where Fire Code Official determines needed.
SECTION 46: RENUMBER "15.07.507.5.5 Clear Space Around Hydrants" of the
Rexburg Municipal Code is hereby renumbered as follows:
RENUMBER
i 5.07.507.5,5 Clear Space Around Hydrants
15.07.340 Clear Space Around Hydrants 507.5.5
SECTION 47: AMENDMENT "15.07.507.5.7 Fire Hydrant Distance From
Buildings" of the Rexburg Municipal Code is hereby amended as follows:
AMENDMENT
15.07.507.5.7 Fire Hydrant Distance From Buildings
Fire hydrants shall not be installed closer than forty (40) feet and/or at access points to buildings. In
such areas of the city where forty (40) feet is an impractical distance, the code official may allow a
lesser distance. Access to hydrants not adjacent to a building or structure's fire lane must be approved
by the fire code official (Ord. 1109 §3(PP), 2014).
SECTION 48: RENUMBER "15.07.507.5.7 Fire Hydrant Models" of the Rexburg
Municipal Code is hereby renumbered as follows:
RENUMBER
15.07.507.5.7 Fire Hvdrant Models
15.07.360 Fire Hydrant Models 507.5.8
SECTION 49: RFN[.1MBER "15.07.509.2 Equipment Access" of the Rexburg
Municipal Code is hereby renumbered as follows:
RENUMBER
15.07.509.2 Eauinment Access
15.07.370 Equipment Access 509.2
SECTION 50: RENUMBER "15.07.901.6.2 Records" of the Rexburg Municipal
Code is hereby renumbered as follows:
RENUMBER
15.07.901.6.2 Records
15.07.380 Records 901.6.2
SECTION 51: ADOPTION- "15.07.390 Group R Automatic Sprinkler System
Installation 903.2.8" of the Rexburg Municipal Code is hereby added as follows:
ADOPTION
15.07.390 Group R Automatic Sprinkler System Installation 903.2.8(Added)
Delete Section 903.2.8 and replace with the following:
903.2.8 Group R. An automatic sprinkler system installed in accordance with Section 903.3 shall be
provided throughout all buildings with a Group R fire area. Exceptions:
1. All single family homes and multiple family dwellings up to two (2) units that are physically
separated by ten (10) feet or more of space, to the nearest building, are hereby exempted from
the provisions of the International Fire Code, the International Building Code and the Idaho
Residential Code that require such dwellings to have automatic fire sprinkler systems
installed. Nothing in this section shall prevent any person from voluntarily installing an
automatic fire sprinkler system in any residential dwelling.
SECTION 52: AMENDMEN "15.07 903.3.7 Fire Department Connections" of
the Rexburg Municipal Code is hereby amended as follows:
AMENDMENT
15.07 903.3.7 Fire Department Connections
The location of fire department connections (FDC) shall be within 150 feet of a hydrant and adjacent
to the fire apparatus access road, installed with clappers, and be 2 112" NH. (Ord. 1096 §3(00),
2012)
SECTION 53: ADOPTION "15.07.410 Certification Of Service Personnel For Fire -
Extinguishing Equipment 904.1.1" of the Rexburg Municipal Code is hereby added as follows:
ADOPTION
15.07.4 10 Certification Of Service Personnel For Fire -Extinguishing Equipment 904.1.1(Added)
If required by the authority having jurisdiction, service personnel providing or conducting
maintenance on automatic fire -extinguishing systems, other than automatic sprinkler systems, shall
possess a valid certificate issued by an approved governmental agency, or other approved organization
for the type of system and work performed.
SECTION 54: RENUMBER "15.07.905.1 General" of the Rexburg Municipal
Code is hereby renumbered as follows:
RENUMBER
15.07.905.1 General
15.07.420 Installation Standard 905.2
SECTION 55: ADOPTION "15.07.430 Certification Of Service Personnel For
Portable Fire 906.2.1" of the Rexburg Municipal Code is hereby added as follows:
ADOPTION
15.07.430 Certification Of Service Personnel For Portable Fire 906.2.1(Added)
Service personnel providing or conducting maintenance on portable fire extinguishers shall possess a
valid certificate issued by an approved governmental agency. Or other approved organization for the
type of work performed.
SECTION 56: RWUMBER, "15.07.906.5 Conspicuous Location" of the Rexburg
Municipal Code is hereby renumbered as follows:
RENUMBER
15.07.906.5 C:onsnicuous Location
15.07.440 Conspicuous Location 906.5
SECTION 57: AMENDMENT "15.07 907.1 General" of the Rexburg Municipal
Code is hereby amended as follows:
AMENDMENT
15.07 907.1 General
This section covers the application, installation, performance, and maintenance of fire alarm systems
and their components in new and existing buildings and structures. The requirements of Section 907.2
are applicable to new buildings and structures. The requirements of Section 907.9 are applicable to
existing buildings and structures. When fire alarm systems not required by the International Fire Code
are installed, the notification devices shall meet the minimum design and installation requirements for
systems which are required by this code.
No partial fire alarm and detection systems shall be allowed (Ord. 1109 §3(ZZ)(part), 2014).
SECTION 58: AMENDMENT "15.07.907.7.1 Wiring" of the Rexburg Municipal
Code is hereby amended as follows:
AMENDMENT
15.07.460 Wiring 907.6.1
Wiring shall comply with the requirements of NFPA 70 and NFPA 72. Wireless protection systems
utilizing radio-frequency transmitting devices shall comply with the special requirements of
supervision of low-power wireless systems in NFPA 72. (Ord. 1109 §3 (AAA), 2014).
SECTION 59: RU UMBER "15.07 907.7.3.2.3 Zone And Address Location
Labeling" of the Rexburg Municipal Code is hereby renumbered as follows:
RENUMBER
15.07 907.7.3.2.3 Zone And Address Location Labeling
15.07.470 Zone And Address Location Labeling 907.6.5
SECTION 60: ADOPTM "15.07.480 Stairway To Roof 1011.12" of the Rexburg
Municipal Code is hereby added as follows:
ADOPTION
15.07.480 Stairway To Roof 1011.12(Added)
In buildings four or more stories above grade plane, one stairway shall extend to the roof surface
unless the roof has a slope steeper than four units vertical in 12 units horizontal (33 -percent slope).
SECTION 61: ADOPTION "15.07.490 Scope 1101.1" of the Rexburg Municipal
Code is hereby added as follows:
ADOPTION
15.07.490 Scope 110 1 .1 ( 4dded)
The provisions of this chapter shall apply to existing buildings constructed prior to the adoption of this
code and only if in the opinion of the fire code official, they constitute a distinct hazard to life or
property.
SECTION 62: 4DOPTION "15.07.500 Deleted Sections" of the Rexburg Municipal
Code is hereby added as follows:
ADOPTION
15.07.500 Deleted Sections(Added)
Delete Sections 5601.1.3, 5601.2.2, 5601.2.3, 5601.2.4.1, 5601.2.4.2, and sections 5608.2, 5608.2.1,
and 5608.3 of the International Fire Code.
SECTION 63: ,ADOPTION "15.07.510 Out Of Service For One Year
5704.2.13.1.3" of the Rexburg Municipal Code is hereby added as follows:
ADOPTION
15.07.5 10 Out Of Service For One Year 5704.2.13.1.3 (Added)
Underground tanks that have been out of service for a period of one year shall be removed from the
ground in accordance with Section 5704.2.14 or abandoned in place in accordance with Section
5704.2.13.1.4. Upon approval of the Chief underground tanks that comply with the performance
standards for new or upgraded underground tanks set forth in Title 40 Section 280.20 or 280.21 of the
Code of Federal Regulations may remain out of service indefinitely so long as they remain in
compliance with the operation, maintenance and release detection requirements of the federal rule.
SECTION 64: $MUMBER, "15.07.B 105.3 Hydrant Testing" of the Rexburg
Municipal Code is hereby renumbered as follows:
RENUMBER
15.07.B 105.3 Hydrant Testing
15.07.520 Water Supply Tests 507.4
SECTION 65: ADOPTI0I1j "15.07.530 Scope D101.1" of the Rexburg Municipal
Code is hereby added as follows:
ADOPTION
15.07.530 Scope D 101.1(Added)
Fire apparatus access roads shall be in accordance with this appendix and all other applicable
requirements of the International Fire Code. Driveways as described in section 503.7 through 503.11
are not subject to the requirements of this appendix.
SECTION 66: ADOPTION "15.07.540 Access And Loading D102.1" of the
Rexburg Municipal Code is hereby added as follows:
ADOPTION
15.07.540 Access And Loading D 102.1 (Added)
Facilities, buildings or portions of buildings hereafter constructed shall be accessible to fire department
apparatus by way of an approved fire apparatus access road designed and maintained to support the
imposed loads of the responding fire apparatus and shall be surface so as to provide all-weather
driving capabilities.
SECTION 67: RENUMBER "I 5.07.D 103.6.2.3 Fire Access Signage" of the
Rexburg Municipal Code is hereby renumbered as follows:
RENUMBER
15.07.1).10.3.6.2.3 Fire Access Siernaee
15.07.550 Signs D103.6
SECTION 68: AMENDMENT "I 5.07.D 105.3 Proximity To Building" of the
Rexburg Municipal Code is hereby amended as follows:
AMENDMENT
15.07.1)105.3 Proximity To Building
Buildings or structures of four stories or less shall have at least one of the required access routes
located within a minimum of 15 feet and maximum of 45 feet from the building, and shall be
positioned parallel to one entire side of the building. Buildings or structures greater than four stories
shall have at least one of the required access routes located within a minimum of 15 feet and
maximum of 30 feet from the building, and shall be positioned parallel to one entire side of the
building. The side of the building of which the aerial fire apparatus access road is positioned shall be
approved by the fire code official.
(Ord. 1109 §3(MMM), 2014)
SECTION 69: AMENDMENT "15.01.130 Fees" of the Rexburg Municipal Code is
hereby amended as follows:
AMENDMENT
15.01.130 Fees
That building permit fees and other inspection fees not identified in Chapter 15.1 Building Codes
above, shall be collected at time of Building Permit issuance and shall be as identified by the current
Citv of Rexbure Master Fee List. (Oni. 1059 §3, 2010)
Refunds: The building official may authorize refunding of any fee paid hereunder which was
erroneously paid or collected. The building official may authorize refunding of not more than 80
percent of the permit fee paid when no work has been done under a permit issued in accordance with
this code. The building official may authorize refunding of not more than 80 percent of the plan
review fee paid when an application for a permit for which a plan review fee has been paid is
withdrawn or canceled before any plan reviewing is done.
SECTION 70: AMENDMENT "15.01.140 Severability" of the Rexburg Municipal
Code is hereby amended as follows:
AMENDMENT
15.01.140 Severability
That if any section, subsection, sentence, clause or phrase of this ordinance is, for any reason, held to
be unconstitutional, such decision shall not affect the validity of the remaining portions of the
ordinance. The Rexburg City Council hereby declares that it would have passed this ordinance, and
each section, subsection, clause or phrase thereof, irrespective of the fact that any one or more
sections, subsections, sentences, clauses and phrases be declared unconstitutional. (Ord. 1059 §5,
2010) That nothing in this ordinance or in the Building Code hereby adopted shall be construed to
affect any suit or proceeding impending in any court, or any rights acquired, or liability incurred, or
any cause or causes of action acquired or existing, under any act or ordinance hereby repealed as cited
in Section 15.01.020 through Section 15.01.070 of this ordinance: nor shall any just or legal right or
remedy of any character lost, impaired or affected by this ordinance. (Oil: 1059 ¢6, 2010.)
SECTION 71: AMENDMENT "15.01.150 Violation - Penalty" of the Rexburg
Municipal Code is hereby amended as follows:
AMENDMENT
15.01.150 Violation - Penalty
Any person, firm, or corporation violating any provision of the Building and Fire Code as described in
Chapters 15.01 and 15.07 of this document, shall upon conviction thereof, be guilty of a general
infraction, which shall be punishable by a fine not to exceed Three Hundred Dollars ($300.00) or by
imprisonment for not more than Six (6) Months, or by both said fine and imprisonment for any single
violation, in addition to any penalty for any sanction provided for in the adopted Building and Fire
Code as described in Chapter 15.01 and Chapter 15.0100707 of this document. Each day of violation
shall constitute a separate offense.
SECTION 72: REPEAL "15.07.114.1 Tags" of the Rexburg Municipal Code is
hereby repealed as follows:
REPEAL.
(Repealed)
Taw tr inopx-2i �3uppou-Gii;in 3y3tZA113, SrZ &K',Vg#t(AC/t3, Gid fire &liar. ✓fMMIL UX. lJ,1uir0e.
to 13:.&xii the RmburgCity-Ulc.- r, ;,ffieie--far u5G li, die Gity of exlrarg (A�. 1107 fK ;jGj;
x&1.4)
SECTION 73: REPEAL "15.07.503.2.2 Turnarounds" of the Rexburg Municipal
Code is hereby repealed as follows:
REPEAL
-1Sz3 (Repealed)
Pi4vev,'ay turn&ivin&-31�ft havr. ca hrt.da turni:+ :✓stria turning
radius a n:/ lzrz fim n 15 fxt. D1iv&wuyo that aenneet
. with
tin neeess ad , ads at "" urc than anc
$Glint timy lam;s as kvilig x�d-if-sH-eh�ng�r of a:- .._ --�t tlyr,:adiUS
l\xiuirzgi--,nts for -driveway tumor
SECTION 74: REPEAL "15.07.503.6 Security Gates" of the Rexburg Municipal
Code is hereby repealed as follows:
REPEAL
-r15.07w503:6SJJall. mo""re(Repealed)
Pira, up'falutun aeeew&ftntaa droll nz.*, k rk/it(:�uved-in any mat�r�, irlrlu� tli:��rl�7iil� zi. i zhiele�
Elie-aeu,1111u1[�WII lfi--3tlow' ov tl,(, gmwing o1 l f':Cat.a7 T1. Thc, ailC/ia �iY'dY1GGf
e:1.GUinhcd in C:rJi-3n403.2.1 L\- at all tun✓ �%LG'. 1107 ,
SECTION 75: REPEAL "15.07.903.1.2 Warehouse Sprinkler Systems" of the
Rexburg Municipal Code is hereby repealed as follows:
REPEAL
1 c 94 993 472 Wir:%i umc &ptinlll:rr Cystem (Repealed)
-An Gut✓11ffd: 3hall ba inatallcd ui v,-arz)h&tse-j•px; liaild rian oftht,
liailding has a. open-erilinb 11✓g11t ✓.✓ t»•d.ve �!2)) feet.
SECTION 76: REPEAL "15.07.903.1.3 Freeze Protection" of the Rexburg
Municipal Code is hereby repealed as follows:
REPEAL
' 1.3 P-roria P-reteetian (Repealed)
AJMN,v� aat mittic &p6nlll✓r sy3tew&in-nevi buildire63 and Mr -Mt -MM dIGll LX 171FIteeted FfOni freeZiflg
to a'ccmpCZG/, ,2012
SECTION 77: REPEAL "15.07.903.2 Where Required" of the Rexburg Municipal
Code is hereby repealed as follows:
REPEAL
1 c 97 903 "'h✓m R✓ai l (Repealed)
7kpprevcd Gut✓uatia v Lui�Ainsl;•••moo �l�ll lx�a-✓ iZ�
leeation esef lea' in D-Aiiatts 903. .1 thr✓agli-993.2.12.
SECTION 78: REPEAL "15.07.4601.1 Scope" of the Rexburg Municipal Code is
hereby repealed as follows:
REPEAL
15-197. 601.1 Eulpe (Repealed)
The pfevisions of this rcr shell apply- tr, uxi31,4ftg4)ti4duigo aumtruat&- priar to tha rdvptiu.i rf. thiu
t --Sr, rag,, only if in-the-ep nlun of the-frr-c a:,, -I„ a:-iem�,-trhv; :uu^iaa+e-n dlcteihic/c hazard to 1i
prepei4y (Ord. 1169 �JDDD), 2314}
SECTION 79: REPEAL "15.07 903.3.8 Approved Piping" of the Rexburg
Municipal Code is hereby repealed as follows:
REPEAL
prv, c� Pipitrg (Repealed)
All l ping ane fittr:. n�ur�il� i��; inning ata mittimurn 4diree fee
4iaii the ✓iwrioT zFthe-bttildirigeFs�njUu.:, rrxdrua h tc pa
With the MZAA U)\3LM. n.+.. to fif- , ,....: :_ .._ a th✓r rlfpdtenarzeri dhall ba tz-4o8-ire
_ G �,3(PP), 2012)
SECTION 80: REPEAL "15.07.D 103.3 Turning Radius" of the Rexburg Municipal
Code is hereby repealed as follows:
REPEAL
04 9 ^2.2 Turning Iir14es (Repealed)
The frAniml r c\tiull :r, -Ali lrms thrna 36 feet ane? rn cm�side WFning radius of
thru 1` ;met($- . 1109
SECTION 81: REPEAL "15.07.903.3.1.2 NFPA 13R Sprinkler Systems" of the
Rexburg Municipal Code is hereby repealed as follows:
REPEAL
(Repealed)
-NN'hux in Imilsinga-af Gr✓ap Il, �� i'�t tree (3) tr ~meltt3 (12) 6w.311nig unit3, autofflatre
sprs��i�� v� ll -LL inU.rlla'. tlir ✓agh✓at in a---zcr. ee-wt'J, rirrA 1311 ✓- NF
SECTION 82: REPEAL "l 5.07 503.7.6 Grade" of the Rexburg Municipal Code is
hereby repealed as follows:
REPEAL
15��—G Crae (Repealed)
The [,nidi /.- elrkvfem)-s-�l c✓ 10 r,✓roent unkm Gpplv\--. (Ord.
SECTION 83: REPEAL "15.07.503.7.8 Surface" of the Rexburg Municipal Code is
hereby repealed as follows:
REPEAL
' `.ter .D fil: face (Repealed)
��?� �I�GII he �� Ili I11G111`tRti3efl l; nlY,�srt tlt: 1111fIJ1Gleads of! a eel fespajidiiig
t.3 p1v;ifG G11 Ni-ocjier drit,ing eapabilities. Driveways shal
Cer33sx:t✓� :lzcwditlg t:, the IGt:,�t vcrY.,3a f ldrh:; PlG
4-1.09 k3(En), 2011).
SECTION 84: REPEAL "15.07.503.7.3 Tumouts" of the Rexburg Municipal Code
is hereby repealed as follows:
REPEAL
icrncn�
Turf✓acs (Repealed)
-Whwt line of fight G Jriv;Nvay is al3stmerIA by a mmi :r, ter:, h:rx; lie
laoatA Gr, nmy Lx;—G a6„ :f. whiata-l3rii�ew�p
e ,/A ail &H -vv& icr .-3ad surfitee at least 10 f�el wide and 30 feet long (9rd. 1109
SECTION 85: REPEAL "15.07.4601.1 Scope" of the Rexburg Municipal Code is
hereby repealed as follows:
REPEAL
(Repealed)
The of tl\ia entrozi- Mhull Gpply tc un tang buildinbt;
eacle-arid :r.\ly if in tl\: :1pii\I(r1 3f t113 fJ3 :UC}e$. lJ.GI, ll\C/.' Ul net h&mri t3 HE Cr
(DDD), 2944}
SECTION 86: REPEALER CLAUSE All ordinances or resolutions or parts
thereof, which are in conflict herewith, are hereby repealed.
SECTION 87: SEVERABILITY CLAUSE Should any part or provision of this
Ordinance be declared by the courts to be unconstitutional or invalid, such decision shall not affect the
validity of the Ordinances a whole or any part thereof other than the part so declared to be
unconstitutional or invalid.
SECTION 88: EFFECTIVE DATE This Ordinance shall be in full force and effect
from January 1, 2021 and after the required approval and publication according to law.
PASSED AND ADOPTED BY THE CITY OF REXBURG COUNCIL DECEMBER I6, 2020.
Rp�R9�;
AYE
NAY ABSENT ABSTAIN
Council President Jordan Busby
X
Councilmember Brad Wolfe
X
Councilmember Tisha Flora
X
Councilmember Christopher Mann
X
Councilmember Mikel Walker
X
Councilmember Bryanna Johnson
X
Presiding Officer
Attest
ooefiA•
.
IX60*%�
Jerry L Merrill, Rexburg Mayor, City of
Deborah Lovejoy, Rexburg City Clerk
Rexburg
City of Rexburg
Rp�R9�;