Loading...
HomeMy WebLinkAboutFIRE ALARM REPORT - 20-00467 - Les Schwab - Fire Alarm replacementFIRE ALARM SYSTEM RECORD OF COMPLETION {NFPA 72. Fig 4.5.2.11 Protected Premise;QS'--- nAddrOr AM: eff Installer., Peak Alarm Comp-aAy-- Service y- Service Org.: Peak Alarm CO any Location of Dwgs: Peak Alarm Office Location of owners manual: On-site Location of Test Reports: On-site Contract for Tests and Inspections dated: 1 Tune of System or Service NFPA 72, Chapter 6 - Local —�-NFPA 72, Chapter 8 - Remote Station Telephone No. of organization receiving Alarms/Supervisory/Troubles: Peak Alarm Company -1(800) 444-7231 NFPA 72, Chapter 8 - Central Station Prime Contractor: Central Station Location: Means of transmission of signals from protected premise to central station:__ �/ DACT None 2 ii.eeord of System Installation This system has been installed IAPB ds as shown below, was inspected by f 2%t6 / to includes the devices shown in 5 and 6; an�VNFFA eon in service since l Zl>c z NFPA 72, Chapters 12 3 4 5 6 7 8 9 1011 70, National Electric Code, Article 760 Manufacturers Instructions Signed: : 71I90— Date Organize ' W. peak Alarm Company — 3. Record of 5 stem O eration Documentation TAW Inspection Testin� orm, Figure 10.6.2.3, of NFPA 72 is attached All operat nal features of this system were tested by I �t r Date,�� and were found to be operating properly JAW the requirements of: UNFPA 72, Chapters 12 3 4 5 6 7 8 9 10 11 NFPA 70, National Electric Code Manufacturers instructions Signed:Date: -j Organizati :Peak Alarm Company — 4 Sipalina LG connected to system (see ]Gine Circuits Quantity and class of S NFPA 72, Table 6.6.1); Quantity: _-- Style:__._ -.---Glass: 5. Alarm snit atina Devices Quantity and lasso initiating device circuits (see NFPA 72, Table 6.5): Class; Qty.,_— MANUAL MPS: Non Coded ` Addressable 3 AUTOMATIC Coverage . Complete Partial (a) Smoke Detectors: Photo i Addressable (b) Duct Detectors: Photo Addressable d Heat Detectors: FT RR FT/RR Addressable (d) Sprinkler Waterflow indicators: Noneoded. r Addressable (e) The alarm verification feature is disable d �^ or enabled___---, changed from seconds to seconds. (f) Other (list): 6. Supervisory 'Sinal Initiatin Devices and Circuits (a)Sprinkler valve tamper switches: (b)Other: i 7.Anncuciators /) Number:__ Y __,Type:�G Location(s): $ Alarm Notification Appliances and Circuits Quantity and class of notification appliance circuits connected to system (see NFPA 72, Table 6.7 Types and quantity of notification appliances installed: (a) Bells With visible (b) Speakers_ With visible (c) Horns a2 _With visible= (d) Chimes With visible (e) other With visible (fl Visible appliances without audible: 9 System Power Supplies (a) Tire Alarm Control Panel Nominal Voltage: zi O _Current rating z6 Overcurrent Protection: Type: Circuit Breaker Trip - Location: 1 ) A 51- C l (b) Secondary (standby) Calculated capacity to drive system, in hours: Battery AH rating: zA-y z 1o. Cents Frequency of tests and inspectic , if o or than 1AW the referenced NFPA standards' System Deviations from the referenced NFPA standards) are: Q Signed:— Title: �Date:vz J Upon completion of the systems) satisfactory test(s) witnessed (if required by the AH1): Signed' Title: