Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
PA SUMMARY - 20-00935 - 3660 Driftwood Dr - New SFR Mechanical
Load Short Form Job:Arnolds Date:11/1/2020 By:Gene Miller Plan:Arnolds Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: gene.mechcompliancesolutions@gmail.com Project Information For:Housley Pumps Design Information HtgClgInfiltration Outsidedb(°F)-788MethodSimplified Insidedb(°F)7075Construction qualityAverage DesignTD(°F)7713Fireplaces0 Daily range-H Inside humidity (%)3050 Moisture difference (gr/lb)35-28 HEATING EQUIPMENTCOOLING EQUIPMENT MakeColeman, Unitary Products GroupMakeColeman, Unitary Products Group TradeCOLEMAN BY JOHNSON CONTROLSTradeCOLEMAN ModelTM9Y040A10MP11CondTC3B2422 AHRI ref8412975CoilCF30AXA1++TXV AHRI ref204606251 Efficiency96 AFUEEfficiency11.5 EER, 13 SEER Heating input40000BtuhSensible cooling21620Btuh Heating output38000BtuhLatent cooling0Btuh Temperature rise50°FTotal cooling21620Btuh Actual air flow826cfmActual air flow800cfm Air flow factor0.022cfm/BtuhAir flow factor0.054cfm/Btuh Static pressure0.90in H2OStatic pressure0.90in H2O Space thermostatLoad sensible heat ratio1.00 ROOM NAMEAreaHtg loadClg loadHtg AVFClg AVF (ft²)(Btuh)(Btuh)(cfm)(cfm) Craft Rm19225107325639 Flex Rm159254113045770 Laundry83405528928 Mud Room10513622113011 Kit/Din/Living Rm1062115735584258299 MF Bath534183792 Master279397314238876 M Bath13216934123822 M TR263828695 M WIC12919810546 Bedroom 219826537325939 Bonus480393515798885 Bedroom 3173258510485856 Bath941447734 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Nov-01 13:47:30 Right-Suite®Universal201919.0.20RSU28163 Page 1 ...\\MCS Heatloss's\\Housley Pump\\Arnold\\Arnolds.rup Calc = MJ8 Front Door faces: S Bedroom 4181273110586157 Mech330000 Entire House33783710414916826800 Other equip loads71331222 Equip. @0.93RSM15024 Latent cooling0 TOTALS33784423715024826800 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Nov-01 13:47:30 Right-Suite®Universal201919.0.20RSU28163 Page 2 ...\\MCS Heatloss's\\Housley Pump\\Arnold\\Arnolds.rup Calc = MJ8 Front Door faces: S Building Analysis Job:Arnolds Date:11/1/2020 By:Gene Miller Plan:Arnolds Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: gene.mechcompliancesolutions@gmail.com Project Information For:Housley Pumps Design Conditions Location:Indoor:HeatingCooling Rexburg Madison Co, ID, USIndoortemperature(°F)7075 Elevation:4859ftDesignTD(°F)7713 Latitude:44°NRelative humidity (%)3050 Outdoor:HeatingCooling Moisture difference (gr/lb)35.4-27.9 Infiltration: Drybulb(°F)-788 Dailyrange(°F)-33(H) MethodSimplified Wetbulb(°F)-60 Construction qualityAverage Wind speed (mph)15.07.5 Fireplaces0 Heating ComponentBtuh/ft²Btuh% of load Walls5.01409731.9 Ventilation Glazing26.8831418.8 Doors29.818804.2 Walls Ceilings1.526906.1 Floors1.91.91370.3 Infiltration3.1998722.6 Infiltration Ducts00 Piping00 Humidification00 Ventilation713316.1 Other Adjustments0 Glazing Ceilings Doors Total44237100.0 Cooling ComponentBtuh/ft²Btuh% of load Walls0.412537.8Ventilation Walls Glazing17.3537233.3 Doors7.04422.7 Ceilings0.814599.0 Floors0.3230.1 GlazingInternalGains Infiltration0.39165.7 Ducts00 Ventilation12227.6 Internal gains545033.8 Blower00 Adjustments0 Doors Infiltration Total16137100.0 Ceilings Other Latent Cooling Load = 0 Btuh OverallU-value=0.070Btuh/ft²-°F Data entries checked. 2020-Nov-01 13:47:30 Right-Suite®Universal201919.0.20RSU28163 Page 1 ...\\MCS Heatloss's\\Housley Pump\\Arnold\\Arnolds.rup Calc = MJ8 Front Door faces: S Component Constructions Job:Arnolds Date:11/1/2020 By:Gene Miller Plan:Arnolds Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: gene.mechcompliancesolutions@gmail.com Project Information For:Housley Pumps Design Conditions Location:Indoor:HeatingCooling Rexburg Madison Co, ID, USIndoor temperature (°F)7075 Elevation:4859ftDesign TD (°F)7713 Latitude:44°NRelative humidity (%)3050 Outdoor:HeatingCooling Moisture difference (gr/lb)35.4-27.9 Infiltration: Dry bulb (°F)-788 Daily range (°F)-33(H) MethodSimplified Wet bulb (°F)-60 Construction qualityAverage Wind speed (mph)15.07.5 Fireplaces0 Construction descriptions OrAreaU-valueInsul RHtg HTMLossClg HTMGain ft²Btuh/ft²-°Fft²-°F/BtuhBtuh/ft²BtuhBtuh/ft²Btuh Walls n5960.06521.04.9729640.44263 12F-0sw: Frm wall, vnl ext, 3/8" wood shth, r-21 cav ins, 1/2" gypsum e7600.06521.04.9737780.44336 board int fnsh, 2"x6" wood frm, 16" o.c. stud s7090.06521.04.9735230.44313 w7710.06521.04.9738330.44341 all28350.06521.04.97140970.441253 Partitions (none) Windows n2280.350026.8609111.22553 2 glazing, clr low-e outr, argon gas, insulated vinyl frm mat, clr innr, 1/4" s730.350026.8195530.52223 gap, 1/8" thk, SHGC .35: 2 glazing, clr low-e outr, argon gas, insulated w100.350026.826847.3473 vinyl frm mat, clr innr, 1/4" gap, 1/8" thk, SHGC .35; foreground = new all3110.350026.8831416.95249 concrete (0.32); 6.67 ft head ht Doors e210.390029.86277.02147 11D0: Door, wd sc type s420.390029.812537.02295 all630.390029.818807.02442 Ceilings 17580.02050.01.5326900.831459 16B-50ad: Attic ceiling, asphalt shingles roof mat, r-50 ceil ins, 1/2" gypsum board int fnsh Floors 720.02938.01.911370.3323 19A-38cvtp: Flr floor, frm flr, 10" thkns, r-38 cav ins, leaky crwl ovr 2020-Nov-01 13:47:30 Right-Suite® Universal 2019 19.0.20 RSU28163 Page 1 ...\\MCS Heatloss's\\Housley Pump\\Arnold\\Arnolds.rup Calc = MJ8 Front Door faces: S Project Summary Job:Arnolds Date:11/1/2020 By:Gene Miller Plan:Arnolds Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: gene.mechcompliancesolutions@gmail.com Project Information For:Housley Pumps Notes:Oversized Equipment is at the Homeowners Request. Design Information Weather:Rexburg Madison Co, ID, US Winter Design ConditionsSummer Design Conditions Outside db-7°FOutside db88°F Inside db70°FInside db75°F Design TD77°FDesign TD13°F Daily rangeH Relative humidity50% Moisture difference-28gr/lb Heating SummarySensible Cooling Equipment Load Sizing Structure37104BtuhStructure14916Btuh Ducts0BtuhDucts0Btuh Central vent (101 cfm)7133BtuhCentral vent (101 cfm)1222Btuh Outside airOutside air Humidification0BtuhBlower0Btuh Piping0Btuh Equipment load44237BtuhUse manufacturer's datan Rate/swing multiplier0.93 Infiltration Equipment sensible load15024Btuh Latent Cooling Equipment Load Sizing MethodSimplified Construction qualityAverage Fireplaces0Structure-208Btuh Ducts0Btuh Central vent (101 cfm)-1610Btuh HeatingCooling Outside air Area (ft²)33783378Equipment latent load0Btuh Volume (ft³)3040430404 Equipment Total Load (Sen+Lat) Air changes/hour0.280.1515024Btuh Equiv. AVF (cfm)14276Req. total capacity at 1.00 SHR1.3ton Heating Equipment SummaryCooling Equipment Summary MakeColeman, Unitary Products GroupMakeColeman, Unitary Products Group TradeCOLEMAN BY JOHNSON CONTROLSTradeCOLEMAN ModelTM9Y040A10MP11CondTC3B2422 AHRI ref8412975CoilCF30AXA1++TXV AHRI ref204606251 Efficiency96 AFUEEfficiency11.5 EER, 13 SEER Heating input40000BtuhSensible cooling21620Btuh Heating output38000BtuhLatent cooling0Btuh Temperature rise50°FTotal cooling21620Btuh Actual air flow826cfmActual air flow800cfm Air flow factor0.022cfm/BtuhAir flow factor0.054cfm/Btuh Static pressure0.90in H2OStatic pressure0.90in H2O Space thermostatLoad sensible heat ratio1.00 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Nov-01 13:47:30 Right-Suite® Universal 2019 19.0.20 RSU28163 Page 1 ...\\MCS Heatloss's\\Housley Pump\\Arnold\\Arnolds.rup Calc = MJ8 Front Door faces: S Right-J®Worksheet Job:Arnolds Date:11/1/2020 By:Gene Miller Mechanical Compliance Solutions Plan:Arnolds 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: gene.mechcompliancesolutions@gmail.com 1Room nameEntire HouseCraft Rm 2Exposed wall356.5ft27.0ft 3Room height9.0ft9.0ftheat/cool 4Room dimensions1.0x191.8ft 5Room area3378.2ft²191.8ft² TyConstructionU-valueOrHTMArea(ft²)LoadArea(ft²)Load number((BBttuuhh//fftt²²--°°FF))((BBttuuhh//fftt²²))orperimeter(ft)(Btuh)orperimeter(ft)(Btuh) HeatCoolGrossN/P/SHeatCoolGrossN/P/SHeatCool 6WW12F-0sw12F-0sw0.0650.065nn4.974.970.440.4482459629642631229748043 .GG2 glazing, clr low-e2 glazing, clr low-e0.3500.350nn26.7726.7711.2211.22228060912553250669281 .WW12F-0sw12F-0sw0.0650.065ee4.974.970.440.4478176037783360000 .DD11D011D00.3900.390ee29.8329.837.027.0221216271470000 11WW12F-0sw12F-0sw0.0650.065ss4.974.970.440.4482470935233130000 GG2 glazing, clr low-e2 glazing, clr low-e0.3500.350ss26.7726.7730.4530.45730195522230000 DD11D011D00.3900.390ss29.8329.837.027.02424212532950000 WW12F-0sw12F-0sw0.0650.065ww4.974.970.440.44781771383334112212260454 GG2 glazing, clr low-e2 glazing, clr low-e0.3500.350ww26.7726.7747.3147.311002684730000 CC16B-50ad16B-50ad0.0200.020--1.531.530.830.8317581758269014590000 FF19A-38cvtp19A-38cvtp0.0290.029--1.911.910.330.337272137230000 6c) AED excursion123-15 Envelope loss/gain2711785491753362 12a)Infiltration998791675669 b)Room ventilation0000 13Internal gains:Occupants @2302305115000 Appliances/other4300300 Subtotal (lines 6 to 13)37104149162510732 Less external loadLess external load0000 Less transferLess transfer0000 RedistributionRedistribution0000 14Subtotal37104149162510732 15Duct loads0%0%00-0%0%00 Total room load37104149162510732 Air required (cfm)Air required (cfm)8268005639 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Nov-01 13:47:30 Right-Suite®Universal201919.0.20RSU28163 Page 1 ...\\MCS Heatloss's\\Housley Pump\\Arnold\\Arnolds.rup Calc = MJ8 Front Door faces: S Right-J®Worksheet Job:Arnolds Date:11/1/2020 By:Gene Miller Mechanical Compliance Solutions Plan:Arnolds 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: gene.mechcompliancesolutions@gmail.com 1Room nameFlex RmLaundry 2Exposed wall27.3ft0ft 3Room height9.0ftheat/cool9.0ftheat/cool 4Room dimensions12.0x13.3ft8.3x10.0ft 5Room area159.0ft²82.5ft² TyConstructionU-valueOrHTMArea(ft²)LoadArea(ft²)Load number((BBttuuhh//fftt²²--°°FF))((BBttuuhh//fftt²²))orperimeter(ft)(Btuh)orperimeter(ft)(Btuh) HeatCoolGrossN/P/SHeatCoolGrossN/P/SHeatCool 6WW12F-0sw12F-0sw0.0650.065nn4.974.970.440.4400000000 .GG2 glazing, clr low-e2 glazing, clr low-e0.3500.350nn26.7726.7711.2211.2200000000 .WW12F-0sw12F-0sw0.0650.065ee4.974.970.440.4418189080000 .DD11D011D00.3900.390ee29.8329.837.027.0200000000 11WW12F-0sw12F-0sw0.0650.065ss4.974.970.440.4410883413370000 GG2 glazing, clr low-e2 glazing, clr low-e0.3500.350ss26.7726.7730.4530.452506697610000 DD11D011D00.3900.390ss29.8329.837.027.0200000000 WW12F-0sw12F-0sw0.0650.065ww4.974.970.440.44119119593530000 GG2 glazing, clr low-e2 glazing, clr low-e0.3500.350ww26.7726.7747.3147.3100000000 CC16B-50ad16B-50ad0.0200.020--1.531.530.830.83991370000 FF19A-38cvtp19A-38cvtp0.0290.029--1.911.910.330.3300000000 6c) AED excursion68-10 Envelope loss/gain17789340-10 12a)Infiltration7637000 b)Room ventilation0000 13Internal gains:Occupants @2302300000 Appliances/other300500 Subtotal (lines 6 to 13)254113040490 Less external loadLess external load0000 Less transferLess transfer0000 RedistributionRedistribution0040538 14Subtotal25411304405528 15Duct loads-0%0%00-0%0%00 Total room load25411304405528 Air required (cfm)Air required (cfm)5770928 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Nov-01 13:47:30 Right-Suite®Universal201919.0.20RSU28163 Page 2 ...\\MCS Heatloss's\\Housley Pump\\Arnold\\Arnolds.rup Calc = MJ8 Front Door faces: S Right-J®Worksheet Job:Arnolds Date:11/1/2020 By:Gene Miller Mechanical Compliance Solutions Plan:Arnolds 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: gene.mechcompliancesolutions@gmail.com 1Room nameMud RoomKit/Din/Living Rm 2Exposed wall8.3ft100.8ft 3Room height9.0ftheat/cool9.0ftheat/cool 4Room dimensions1.0x104.9ft1.0x1061.8ft 5Room area104.9ft²1061.8ft² TyConstructionU-valueOrHTMArea(ft²)LoadArea(ft²)Load number((BBttuuhh//fftt²²--°°FF))((BBttuuhh//fftt²²))orperimeter(ft)(Btuh)orperimeter(ft)(Btuh) HeatCoolGrossN/P/SHeatCoolGrossN/P/SHeatCool 6WW12F-0sw12F-0sw0.0650.065nn4.974.970.440.44000029017888479 .GG2 glazing, clr low-e2 glazing, clr low-e0.3500.350nn26.7726.7711.2211.220000113030121262 .WW12F-0sw12F-0sw0.0650.065ee4.974.970.440.4400003533321652147 .DD11D011D00.3900.390ee29.8329.837.027.0200002121627147 11WW12F-0sw12F-0sw0.0650.065ss4.974.970.440.4474532652415111255649 GG2 glazing, clr low-e2 glazing, clr low-e0.3500.350ss26.7726.7730.4530.450000180482548 DD11D011D00.3900.390ss29.8329.837.027.0221216271472121627147 WW12F-0sw12F-0sw0.0650.065ww4.974.970.440.44000011311355950 GG2 glazing, clr low-e2 glazing, clr low-e0.3500.350ww26.7726.7747.3147.3100000000 CC16B-50ad16B-50ad0.0200.020--1.531.530.830.83000050507641 FF19A-38cvtp19A-38cvtp0.0290.029--1.911.910.330.3300000000 6c) AED excursion-4-72 Envelope loss/gain89116784742399 12a)Infiltration231212822259 b)Room ventilation0000 13Internal gains:Occupants @2302300000 Appliances/other02900 Subtotal (lines 6 to 13)1122188112965558 Less external loadLess external load0000 Less transferLess transfer0000 RedistributionRedistribution2392227626 14Subtotal1362211115735584 15Duct loads-0%0%00-0%0%00 Total room load1362211115735584 Air required (cfm)Air required (cfm)3011258299 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Nov-01 13:47:30 Right-Suite®Universal201919.0.20RSU28163 Page 3 ...\\MCS Heatloss's\\Housley Pump\\Arnold\\Arnolds.rup Calc = MJ8 Front Door faces: S Right-J®Worksheet Job:Arnolds Date:11/1/2020 By:Gene Miller Mechanical Compliance Solutions Plan:Arnolds 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: gene.mechcompliancesolutions@gmail.com 1Room nameMF BathMaster 2Exposed wall5.8ft33.8ft 3Room height9.0ftheat/cool9.0ftheat/cool 4Room dimensions9.3x5.8ft14.5x19.3ft 5Room area53.2ft²279.1ft² TyConstructionU-valueOrHTMArea(ft²)LoadArea(ft²)Load number((BBttuuhh//fftt²²--°°FF))((BBttuuhh//fftt²²))orperimeter(ft)(Btuh)orperimeter(ft)(Btuh) HeatCoolGrossN/P/SHeatCoolGrossN/P/SHeatCool 6WW12F-0sw12F-0sw0.0650.065nn4.974.970.440.4400001318140036 .GG2 glazing, clr low-e2 glazing, clr low-e0.3500.350nn26.7726.7711.2211.2200005001339561 .WW12F-0sw12F-0sw0.0650.065ee4.974.970.440.4400000000 .DD11D011D00.3900.390ee29.8329.837.027.0200000000 11WW12F-0sw12F-0sw0.0650.065ss4.974.970.440.4400000000 GG2 glazing, clr low-e2 glazing, clr low-e0.3500.350ss26.7726.7730.4530.4500000000 DD11D011D00.3900.390ss29.8329.837.027.0200000000 WW12F-0sw12F-0sw0.0650.065ww4.974.970.440.4452522572317317386177 GG2 glazing, clr low-e2 glazing, clr low-e0.3500.350ww26.7726.7747.3147.3100000000 CC16B-50ad16B-50ad0.0200.020--1.531.530.830.830000279279427232 FF19A-38cvtp19A-38cvtp0.0290.029--1.911.910.330.3300000000 6c) AED excursion-1-29 Envelope loss/gain257223028876 12a)Infiltration1611594587 b)Room ventilation0000 13Internal gains:Occupants @230230002460 Appliances/other00 Subtotal (lines 6 to 13)4183739731423 Less external loadLess external load0000 Less transferLess transfer0000 RedistributionRedistribution0000 14Subtotal4183739731423 15Duct loads-0%0%00-0%0%00 Total room load4183739731423 Air required (cfm)Air required (cfm)928876 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Nov-01 13:47:30 Right-Suite®Universal201919.0.20RSU28163 Page 4 ...\\MCS Heatloss's\\Housley Pump\\Arnold\\Arnolds.rup Calc = MJ8 Front Door faces: S Right-J®Worksheet Job:Arnolds Date:11/1/2020 By:Gene Miller Mechanical Compliance Solutions Plan:Arnolds 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: gene.mechcompliancesolutions@gmail.com 1Room nameM BathM TR 2Exposed wall14.5ft3.5ft 3Room height9.0ftheat/cool9.0ftheat/cool 4Room dimensions1.0x131.8ft3.5x7.5ft 5Room area131.8ft²26.3ft² TyConstructionU-valueOrHTMArea(ft²)LoadArea(ft²)Load number((BBttuuhh//fftt²²--°°FF))((BBttuuhh//fftt²²))orperimeter(ft)(Btuh)orperimeter(ft)(Btuh) HeatCoolGrossN/P/SHeatCoolGrossN/P/SHeatCool 6WW12F-0sw12F-0sw0.0650.065nn4.974.970.440.4413111154949322813712 .GG2 glazing, clr low-e2 glazing, clr low-e0.3500.350nn26.7726.7711.2211.222005352244010745 .WW12F-0sw12F-0sw0.0650.065ee4.974.970.440.4400000000 .DD11D011D00.3900.390ee29.8329.837.027.0200000000 11WW12F-0sw12F-0sw0.0650.065ss4.974.970.440.4400000000 GG2 glazing, clr low-e2 glazing, clr low-e0.3500.350ss26.7726.7730.4530.4500000000 DD11D011D00.3900.390ss29.8329.837.027.0200000000 WW12F-0sw12F-0sw0.0650.065ww4.974.970.440.4400000000 GG2 glazing, clr low-e2 glazing, clr low-e0.3500.350ww26.7726.7747.3147.3100000000 CC16B-50ad16B-50ad0.0200.020--1.531.530.830.8313213220210926264022 FF19A-38cvtp19A-38cvtp0.0290.029--1.911.910.330.3300000000 6c) AED excursion-8-2 Envelope loss/gain128737428477 12a)Infiltration40637989 b)Room ventilation0000 13Internal gains:Occupants @2302300000 Appliances/other00 Subtotal (lines 6 to 13)169341238286 Less external loadLess external load0000 Less transferLess transfer0000 RedistributionRedistribution0000 14Subtotal169341238286 15Duct loads-0%0%00-0%0%00 Total room load169341238286 Air required (cfm)Air required (cfm)382295 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Nov-01 13:47:30 Right-Suite®Universal201919.0.20RSU28163 Page 5 ...\\MCS Heatloss's\\Housley Pump\\Arnold\\Arnolds.rup Calc = MJ8 Front Door faces: S Right-J®Worksheet Job:Arnolds Date:11/1/2020 By:Gene Miller Mechanical Compliance Solutions Plan:Arnolds 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: gene.mechcompliancesolutions@gmail.com 1Room nameM WICBedroom 2 2Exposed wall0ft27.5ft 3Room height9.0ftheat/cool9.0ftheat/cool 4Room dimensions1.0x129.3ft1.0x198.0ft 5Room area129.3ft²198.0ft² TyConstructionU-valueOrHTMArea(ft²)LoadArea(ft²)Load number((BBttuuhh//fftt²²--°°FF))((BBttuuhh//fftt²²))orperimeter(ft)(Btuh)orperimeter(ft)(Btuh) HeatCoolGrossN/P/SHeatCoolGrossN/P/SHeatCool 6WW12F-0sw12F-0sw0.0650.065nn4.974.970.440.44000011910351346 .GG2 glazing, clr low-e2 glazing, clr low-e0.3500.350nn26.7726.7711.2211.220000160428180 .WW12F-0sw12F-0sw0.0650.065ee4.974.970.440.44000012812863857 .DD11D011D00.3900.390ee29.8329.837.027.0200000000 11WW12F-0sw12F-0sw0.0650.065ss4.974.970.440.4400000000 GG2 glazing, clr low-e2 glazing, clr low-e0.3500.350ss26.7726.7730.4530.4500000000 DD11D011D00.3900.390ss29.8329.837.027.0200000000 WW12F-0sw12F-0sw0.0650.065ww4.974.970.440.4400000000 GG2 glazing, clr low-e2 glazing, clr low-e0.3500.350ww26.7726.7747.3147.3100000000 CC16B-50ad16B-50ad0.0200.020--1.531.530.830.83129129198107198198303164 FF19A-38cvtp19A-38cvtp0.0290.029--1.911.910.330.3300000000 6c) AED excursion-2-15 Envelope loss/gain1981051882432 12a)Infiltration0077071 b)Room ventilation0000 13Internal gains:Occupants @230230001230 Appliances/other00 Subtotal (lines 6 to 13)1981052653732 Less external loadLess external load0000 Less transferLess transfer0000 RedistributionRedistribution0000 14Subtotal1981052653732 15Duct loads-0%0%00-0%0%00 Total room load1981052653732 Air required (cfm)Air required (cfm)465939 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Nov-01 13:47:30 Right-Suite®Universal201919.0.20RSU28163 Page 6 ...\\MCS Heatloss's\\Housley Pump\\Arnold\\Arnolds.rup Calc = MJ8 Front Door faces: S Right-J®Worksheet Job:Arnolds Date:11/1/2020 By:Gene Miller Mechanical Compliance Solutions Plan:Arnolds 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: gene.mechcompliancesolutions@gmail.com 1Room nameBonusBedroom 3 2Exposed wall41.0ft25.8ft 3Room height9.0ftheat/cool9.0ftheat/cool 4Room dimensions1.0x479.6ft1.0x172.9ft 5Room area479.6ft²172.9ft² TyConstructionU-valueOrHTMArea(ft²)LoadArea(ft²)Load number((BBttuuhh//fftt²²--°°FF))((BBttuuhh//fftt²²))orperimeter(ft)(Btuh)orperimeter(ft)(Btuh) HeatCoolGrossN/P/SHeatCoolGrossN/P/SHeatCool 6WW12F-0sw12F-0sw0.0650.065nn4.974.970.440.4400000000 .GG2 glazing, clr low-e2 glazing, clr low-e0.3500.350nn26.7726.7711.2211.2200000000 .WW12F-0sw12F-0sw0.0650.065ee4.974.970.440.441351356716011311355950 .DD11D011D00.3900.390ee29.8329.837.027.0200000000 11WW12F-0sw12F-0sw0.0650.065ss4.974.970.440.441441447166411910451846 GG2 glazing, clr low-e2 glazing, clr low-e0.3500.350ss26.7726.7730.4530.450000150402457 DD11D011D00.3900.390ss29.8329.837.027.0200000000 WW12F-0sw12F-0sw0.0650.065ww4.974.970.440.449080398350000 GG2 glazing, clr low-e2 glazing, clr low-e0.3500.350ww26.7726.7747.3147.311002684730000 CC16B-50ad16B-50ad0.0200.020--1.531.530.830.83480480734398173173265144 FF19A-38cvtp19A-38cvtp0.0290.029--1.911.910.330.330000636312021 6c) AED excursion14435 Envelope loss/gain278711741864752 12a)Infiltration114910572166 b)Room ventilation0000 13Internal gains:Occupants @230230001230 Appliances/other3000 Subtotal (lines 6 to 13)3935157925851048 Less external loadLess external load0000 Less transferLess transfer0000 RedistributionRedistribution0000 14Subtotal3935157925851048 15Duct loads-0%0%00-0%0%00 Total room load3935157925851048 Air required (cfm)Air required (cfm)88855856 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Nov-01 13:47:30 Right-Suite®Universal201919.0.20RSU28163 Page 7 ...\\MCS Heatloss's\\Housley Pump\\Arnold\\Arnolds.rup Calc = MJ8 Front Door faces: S Right-J®Worksheet Job:Arnolds Date:11/1/2020 By:Gene Miller Mechanical Compliance Solutions Plan:Arnolds 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: gene.mechcompliancesolutions@gmail.com 1Room nameBathBedroom 4 2Exposed wall0ft29.0ft 3Room height9.0ftheat/cool9.0ftheat/cool 4Room dimensions14.5x6.5ft1.0x181.0ft 5Room area94.3ft²181.0ft² TyConstructionU-valueOrHTMArea(ft²)LoadArea(ft²)Load number((BBttuuhh//fftt²²--°°FF))((BBttuuhh//fftt²²))orperimeter(ft)(Btuh)orperimeter(ft)(Btuh) HeatCoolGrossN/P/SHeatCoolGrossN/P/SHeatCool 6WW12F-0sw12F-0sw0.0650.065nn4.974.970.440.4400000000 .GG2 glazing, clr low-e2 glazing, clr low-e0.3500.350nn26.7726.7711.2211.2200000000 .WW12F-0sw12F-0sw0.0650.065ee4.974.970.440.4400000000 .DD11D011D00.3900.390ee29.8329.837.027.0200000000 11WW12F-0sw12F-0sw0.0650.065ss4.974.970.440.44000014913466459 GG2 glazing, clr low-e2 glazing, clr low-e0.3500.350ss26.7726.7730.4530.450000150402457 DD11D011D00.3900.390ss29.8329.837.027.0200000000 WW12F-0sw12F-0sw0.0650.065ww4.974.970.440.44000011311355950 GG2 glazing, clr low-e2 glazing, clr low-e0.3500.350ww26.7726.7747.3147.3100000000 CC16B-50ad16B-50ad0.0200.020--1.531.530.830.83949414478181181277150 FF19A-38cvtp19A-38cvtp0.0290.029--1.911.910.330.33000099173 6c) AED excursion-235 Envelope loss/gain144771919754 12a)Infiltration0081275 b)Room ventilation0000 13Internal gains:Occupants @230230001230 Appliances/other00 Subtotal (lines 6 to 13)1447727311058 Less external loadLess external load0000 Less transferLess transfer0000 RedistributionRedistribution0000 14Subtotal1447727311058 15Duct loads-0%0%00-0%0%00 Total room load1447727311058 Air required (cfm)Air required (cfm)346157 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Nov-01 13:47:30 Right-Suite®Universal201919.0.20RSU28163 Page 8 ...\\MCS Heatloss's\\Housley Pump\\Arnold\\Arnolds.rup Calc = MJ8 Front Door faces: S Right-J®Worksheet Job:Arnolds Date:11/1/2020 By:Gene Miller Mechanical Compliance Solutions Plan:Arnolds 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: gene.mechcompliancesolutions@gmail.com 1Room nameMech 2Exposed wall12.5ft 3Room height9.0ftheat/cool 4Room dimensions8.8x3.8ft 5Room area32.8ft² TyConstructionU-valueOrHTMArea(ft²)LoadAreaLoad number(Btuh/ft²-°F)(Btuh/ft²)orperimeter(ft)(Btuh)orperimeter HeatCoolGrossN/P/SHeatCoolGrossN/P/SHeatCool 6W12F-0sw0.065n4.970.440000 .G2 glazing, clr low-e0.350n26.7711.220000 .W12F-0sw0.065e4.970.44343416815 .D11D00.390e29.837.020000 11W12F-0sw0.065s4.970.44797939235 G2 glazing, clr low-e0.350s26.7730.450000 D11D00.390s29.837.020000 W12F-0sw0.065w4.970.440000 G2 glazing, clr low-e0.350w26.7747.310000 C16B-50ad0.020-1.530.8388116 F19A-38cvtp0.029-1.910.330000 6c) AED excursion-2 Envelope loss/gain57154 12a)Infiltration35032 b)Room ventilation00 13Internal gains:Occupants @23000 Appliances/other0 Subtotal (lines 6 to 13)92186 Less external load00 Less transfer00 Redistribution-921-86 14Subtotal00 15Duct loads-0%0%00 Total room load00 Air required (cfm)00 Calculations approved by ACCA to meet all requirements of Manual J 8th Ed. 2020-Nov-01 13:47:30 Right-Suite®Universal201919.0.20RSU28163 Page 9 ...\\MCS Heatloss's\\Housley Pump\\Arnold\\Arnolds.rup Calc = MJ8 Front Door faces: S N Crawl Space Dsbxm!Tqbdf Job #: Arnolds Scale: 1 : 78 Mechanical Compliance Solutions Performed by Gene Miller for: Page 1 Housley Pumps 4181 Aschli lane Right-Suite®Universal2019 Idaho Falls, ID 83406 19.0.20 RSU28163 Phone: 208-881-3243 2020-Nov-01 13:47:45 gene.mechcompliancesolutions@gmail.com ...\\Housley Pump\\Arnold\\Arnolds.rup N Main 60 cfm 60 cfm 60 cfm60 cfm 56 cfm Dsbgu!Sn 6 " 6 " 6 "6 " 6 "6 "6 "6 " 56 cfm6 " Lju0Ejo0Mjwjoh!Sn 9 cfm NG!Cbui 6 " 6 " 341 cfm8 x 8 6 " 12 x 8 28 cfm 6 " 8 x 8 8 " 10 " Mbvoesz Qbousz Nve!Sppn 6 "8 " 14 x 8 6 " 6 " 6 " 6 " 14x3.2530 cfm 6 " 6 " 26 x 8 Nfdi 70 cfm 10 x 8 8 x 8 6 " 24 x 8 10 x 8 8 x 8 12 x 8 6 " 6 "6 " Gmfy!Sn 12 x 8 60 cfm 70 cfm Gsfti!bjs!xjmm!cf!tvqqmjfe!xjui!b!qjqf!boe!ebnqfs 14 x 8 buubdife!up!uif!sfuvso!boe!fyufoefe!up!uif!fyufsjps pg!uif!cvjmejoh Job #: Arnolds Scale: 1 : 78 Mechanical Compliance Solutions Performed by Gene Miller for: Page 2 Housley Pumps 4181 Aschli lane Right-Suite®Universal2019 Idaho Falls, ID 83406 19.0.20 RSU28163 Phone: 208-881-3243 2020-Nov-01 13:47:45 gene.mechcompliancesolutions@gmail.com ...\\Housley Pump\\Arnold\\Arnolds.rup N 2nd Floor 44 cfm59 cfm 38 cfm 44 cfm N!US N!Cbui Cfesppn!3 9 cfm 6 cfm Nbtufs N!XJD 59 cfm 139 cfm Cbui 91 cfm 4 cfm Cpovt 88 cfm 58 cfm 61 cfm Cfesppn!4 Cfesppn!5 61 cfm58 cfm Job #: Arnolds Scale: 1 : 78 Mechanical Compliance Solutions Performed by Gene Miller for: Page 3 Housley Pumps 4181 Aschli lane Right-Suite®Universal2019 Idaho Falls, ID 83406 19.0.20 RSU28163 Phone: 208-881-3243 2020-Nov-01 13:47:45 gene.mechcompliancesolutions@gmail.com ...\\Housley Pump\\Arnold\\Arnolds.rup Duct System Summary Job:Arnolds Date:11/1/2020 By:Gene Miller Plan:Arnolds Mechanical Compliance Solutions 4181 Aschli lane, Idaho Falls, ID 83406 Phone: 208-881-3243 Email: gene.mechcompliancesolutions@gmail.com Project Information For:Housley Pumps HeatingCooling External static pressure0.90in H2O0.90in H2O Pressure losses0.41in H2O0.41in H2O Available static pressure0.49in H2O0.49in H2O Supply / return available pressure0.374 / 0.116in H2O0.374 / 0.116in H2O Lowest friction rate0.043in/100ft0.043in/100ft Actual air flow826cfm800cfm Total effective length (TEL)1133ft Supply Branch Detail Table DesignHtgClgDesignDiamH x WDuctActualFtg.Eqv Name(Btuh)(cfm)(cfm)FR(in)(in)MatlLn (ft)Ln (ft)Trunk Bath c77340.1826.00x0ShMt11.0195.0st4 Bedroom 2 h265359390.0516.00x0ShMt40.8690.0st6 Bedroom 3 h258558560.1766.00x0ShMt18.3195.0st4 Bedroom 4 h273161570.1226.00x0ShMt26.8280.0st4B Bonus h15798885000x0ShMt00 Craft Rm h251056390.0796.00x0ShMt46.0430.0st3 Flex Rm c130457700.1116.00x0ShMt31.3305.0st2 Kit/Din/Living Rm c111752600.1276.00x0ShMt35.5260.0st4A Kit/Din/Living Rm-A c111752600.1166.00x0ShMt31.5290.0st5 Kit/Din/Living Rm-B c111752600.0436.00x0ShMt46.0820.0st6 Kit/Din/Living Rm-C c111752600.0586.00x0ShMt49.0595.0st7 Kit/Din/Living Rm-D c111752600.1316.00x0ShMt16.3270.0st4A Laundry c5289280.1726.00x0ShMt12.5205.0st4 M Bath h169338220.1306.00x0ShMt37.5250.0st4A M TR h382950.0926.00x0ShMt30.5375.0st5A M WIC c105460.1526.00x0ShMt21.5225.0st5 MF Bath h418920.0956.00x0ShMt29.5365.0st3 Master h198744380.0766.00x0ShMt49.8440.0st3 Master-A h198744380.1136.00x0ShMt41.5290.0st4B Mud Room h136230110.0656.00x0ShMt13.0560.0st5A 2020-Nov-01 13:47:30 Right-Suite®Universal201919.0.20RSU28163 Page 1 ...\\MCS Heatloss's\\Housley Pump\\Arnold\\Arnolds.rup Calc = MJ8 Front Door faces: S Supply Trunk Detail Table TrunkHtgClgDesignVelocDiamH x WDuct NameType(cfm)(cfm)FR(fpm)(in)(in)MaterialTrunk st2Peak AVF57700.1113566.00x0ShtMetlst4B st3Peak AVF109790.0762466.48x8ShtMetlst4B st4Peak AVF4824750.07661911.18x14ShtMetlst1 st5APeak AVF2011750.0433629.08x10ShtMetlst5 st6Peak AVF111990.0432497.28x8ShtMetlst5A st4APeak AVF4123860.07661810.48x12ShtMetlst4 st5Peak AVF2572410.0433859.88x12ShtMetlst1 st4BPeak AVF2712440.0764888.98x10ShtMetlst4A st7Peak AVF52600.0581355.48x8ShtMetlst5A st1Peak AVF7387150.04355414.68x24ShtMetl Return Branch Detail Table GrilleHtgClgTELDesignVelocDiamH x WStud/JoistDuct NameSize (in)(cfm)(cfm)(ft)FR(fpm)(in)(in)Opening (in)MatlTrunk rb10x0306341147.50.07862510.00x0ShMtrt1 rb20x09189267.30.0432608.00x0ShMtrt3 rb90x05939225.30.0513016.00x0ShMtrt3 rb30x0139109209.30.0553988.00x0ShMtrt2A rb40x06157212.80.0543106.00x0ShMtrt2A rb50x05856165.30.0701825.13.25x1410x9SJSprt2 rb70x05639249.30.0462856.00x0ShMtrt2A rb80x05770251.00.0463566.00x0ShMtrt2A Return Trunk Detail Table TrunkHtgClgDesignVelocDiamH x WDuct NameType(cfm)(cfm)FR(fpm)(in)(in)MaterialTrunk rt2Peak AVF3703310.04647611.18x14ShtMetlrt1 rt1Peak AVF8268000.04357215.28x26ShtMetl rt3Peak AVF1501280.0433378.08x8ShtMetlrt1 rt2APeak AVF3122750.04646810.48x12ShtMetlrt2 2020-Nov-01 13:47:30 Right-Suite®Universal201919.0.20RSU28163 Page 2 ...\\MCS Heatloss's\\Housley Pump\\Arnold\\Arnolds.rup Calc = MJ8 Front Door faces: S