Loading...
HomeMy WebLinkAboutRESCHECK - 20-00907 - 9442 Rustlers Trl - New SFR MechanicalREScheck Software Version 4.6.5 Compliance Certificate Project The Kelly Project Energy Code:2015 IECC Location:Rexburg, Idaho Construction Type:Single-family Project Type:New Construction Conditioned Floor Area:4,419 ft2 Glazing Area 18% Climate Zone:6 (8693 HDD) Permit Date:09/08/2020 Construction Site: 9494 Rustlers Trail Rexburg, ID 83448 Owner/Agent: Odyssey Homes Odyssey Homes 9494 Rustlers Trail Rexburg, ID 83448 208-604-6586 taylor@buildguardian.com Designer/Contractor: The Energy Auditor The Energy Auditor 1810 Curlew Drive Ammon, Id 83406 208-721-2524 Brian@theenergyauditor.net Permit Number: Compliance: Passes using UA trade-off 2.4% Better Than Code Maximum UA:415 Your UA:405 The % Better or Worse Than Code Index reflects how close to compliance the house is based on code trade-off rules. It DOES NOT provide an estimate of energy use or cost relative to a minimum-code home. Compliance: Envelope Assemblies Assembly Gross Area or Perimeter Cavity R-Value Cont. R-Value U-Factor UA Wall 1: Wood Frame, 16" o.c.500 21.0 0.0 0.057 27 Window 1: 4A5-2ov:2 glazing, clr low-e outr, argon gas, insulated vinyl frm 24 0.270 7 Wall 2: Wood Frame, 16" o.c.639 21.0 0.0 0.057 27 Door 1: Solid 48 0.127 6 Window 1: 4A5-2ov:2 glazing, clr low-e outr, argon gas, insulated vinyl frm 20 0.270 5 Window 2: 4A5-2ov:2 glazing, clr low-e outr, argon gas, insulated vinyl frm 25 0.300 8 Window 3: 4A5-2ov:2 glazing, clr low-e outr, argon gas, insulated vinyl frm 79 0.300 24 Wall 3: Wood Frame, 16" o.c.665 21.0 0.0 0.057 34 Door 1: Solid 24 0.127 3 Window 1: 4A5-2ov:2 glazing, clr low-e outr, argon gas, insulated vinyl frm 42 0.270 11 Wall 4: Wood Frame, 16" o.c.1,210 21.0 0.0 0.057 51 Door 2: Solid 24 0.127 3 Door 1: Glass 54 0.250 14 Window 1: 4A5-2ov:2 glazing, clr low-e outr, argon gas, insulated vinyl frm 163 0.270 44 Window 2: 4A5-2ov:2 glazing, clr low-e outr, argon gas, insulated vinyl frm 30 0.300 9 Project Title: The Kelly Project Data filename: C:\Users\Brian_2\OneDrive - The Energy Auditor Inc\Active Incentive Contractors\Guardian Homes\2020 Mario Projects\Un-Invoiced\new man J\PLAN - Kelley, Alise & Austin\The Kelly Project.rck Page 1 of 10 11/18/20Report date: Assembly Gross Area or Perimeter Cavity R-Value Cont. R-Value U-Factor UA Window 3: 4A5-2ov:2 glazing, clr low-e outr, argon gas, insulated vinyl frm 40 0.300 12 Window 4: 4A5-2ov:2 glazing, clr low-e outr, argon gas, insulated vinyl frm 12 0.550 7 Basement Wall 1: Solid Concrete or Masonry Wall height: 9.2' Depth below grade: 8.0' Insulation depth: 9.2' 459 19.0 0.0 0.044 19 Window 1: 4A5-2ov:2 glazing, clr low-e outr, argon gas, insulated vinyl frm 20 0.300 6 Basement Wall 2: Solid Concrete or Masonry Wall height: 9.2' Depth below grade: 8.0' Insulation depth: 9.2' 338 19.0 0.0 0.044 14 Window 1: 4A5-2ov:2 glazing, clr low-e outr, argon gas, insulated vinyl frm 9 0.270 2 Window 2: 4A5-2ov:2 glazing, clr low-e outr, argon gas, insulated vinyl frm 20 0.300 6 Basement Wall 3: Solid Concrete or Masonry Wall height: 9.2' Depth below grade: 8.0' Insulation depth: 9.2' 158 19.0 0.0 0.044 7 Ceiling 1: Flat Ceiling or Scissor Truss 2,264 50.0 0.0 0.026 59 Name - Title Signature Date Compliance Statement: The proposed building design described here is consistent with the building plans, specifications, and other calculations submitted with the permit application. The proposed building has been designed to meet the 2015 IECC requirements in REScheck Version 4.6.5 and to comply with the mandatory requirements listed in the REScheck Inspection Checklist. Project Notes: Job Number: 11/18/2020-02 ResCheck Only Project Title: The Kelly Project Data filename: C:\Users\Brian_2\OneDrive - The Energy Auditor Inc\Active Incentive Contractors\Guardian Homes\2020 Mario Projects\Un-Invoiced\new man J\PLAN - Kelley, Alise & Austin\The Kelly Project.rck Page 2 of 10 11/18/20Report date: Inspection Checklist Requirements: 100.0% were addressed directly in the REScheck software REScheck Software Version 4.6.5 Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Energy Code: 2015 IECC Section # & Req.ID Pre-Inspection/Plan Review Plans Verified Value Field Verified Value Complies?Comments/Assumptions 103.1, 103.2 [PR1]1 Construction drawings and documentation demonstrate energy code compliance for the building envelope. Thermal envelope represented on construction documents. Complies Does Not Not Observable Not Applicable Requirement will be met. 103.1, 103.2, 403.7 [PR3]1 Construction drawings and documentation demonstrate energy code compliance for lighting and mechanical systems. Systems serving multiple dwelling units must demonstrate compliance with the IECC Commercial Provisions. Complies Does Not Not Observable Not Applicable Requirement will be met. 302.1, 403.7 [PR2]2 Heating and cooling equipment is sized per ACCA Manual S based on loads calculated per ACCA Manual J or other methods approved by the code official. Heating: Btu/hr_____ Cooling: Btu/hr_____ Heating: Btu/hr_____ Cooling: Btu/hr_____ Complies Does Not Not Observable Not Applicable Requirement will be met. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: The Kelly Project Data filename: C:\Users\Brian_2\OneDrive - The Energy Auditor Inc\Active Incentive Contractors\Guardian Homes\2020 Mario Projects\Un-Invoiced\new man J\PLAN - Kelley, Alise & Austin\The Kelly Project.rck Page 3 of 10 11/18/20Report date: Section # & Req.ID Foundation Inspection Plans Verified Value Field Verified Value Complies?Comments/Assumptions 402.1.1 [FO4]1 Conditioned basement wall insulation R-value. Where interior insulation is used, verification may need to occur during Insulation Inspection. Not required in warm-humid locations in Climate Zone 3. R-_____ R-_____ R-_____ R-_____ Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 303.2 [FO5]1 Conditioned basement wall insulation installed per manufacturer’s instructions. Complies Does Not Not Observable Not Applicable Requirement will be met. 402.2.9 [FO6]1 Conditioned basement wall insulation depth of burial or distance from top of wall. _____ ft _____ ft Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 303.2.1 [FO11]2 A protective covering is installed to protect exposed exterior insulation and extends a minimum of 6 in. below grade. Complies Does Not Not Observable Not Applicable Exception: Requirement is not applicable. 403.9 [FO12]2 Snow- and ice-melting system controls installed. Complies Does Not Not Observable Not Applicable Exception: Requirement is not applicable. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: The Kelly Project Data filename: C:\Users\Brian_2\OneDrive - The Energy Auditor Inc\Active Incentive Contractors\Guardian Homes\2020 Mario Projects\Un-Invoiced\new man J\PLAN - Kelley, Alise & Austin\The Kelly Project.rck Page 4 of 10 11/18/20Report date: Section # & Req.ID Framing / Rough-In Inspection Plans Verified Value Field Verified Value Complies?Comments/Assumptions 402.1.1, 402.3.4 [FR1]1 Door U-factor.U-_____U-_____Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 402.1.1, 402.3.1, 402.3.3, 402.5 [FR2]1 Glazing U-factor (area-weighted average). U-_____U-_____Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 303.1.3 [FR4]1 U-factors of fenestration products are determined in accordance with the NFRC test procedure or taken from the default table. Complies Does Not Not Observable Not Applicable Requirement will be met. 402.4.1.1 [FR23]1 Air barrier and thermal barrier installed per manufacturer’s instructions. Complies Does Not Not Observable Not Applicable Requirement will be met. 402.4.3 [FR20]1 Fenestration that is not site built is listed and labeled as meeting AAMA /WDMA/CSA 101/I.S.2/A440 or has infiltration rates per NFRC 400 that do not exceed code limits. Complies Does Not Not Observable Not Applicable Requirement will be met. 402.4.5 [FR16]2 IC-rated recessed lighting fixtures sealed at housing/interior finish and labeled to indicate ≤2.0 cfm leakage at 75 Pa. Complies Does Not Not Observable Not Applicable Requirement will be met. 403.3.1 [FR12]1 Supply and return ducts in attics insulated >= R-8 where duct is >= 3 inches in diameter and >= R-6 where < 3 inches. Supply and return ducts in other portions of the building insulated >= R-6 for diameter >= 3 inches and R-4.2 for < 3 inches in diameter. Complies Does Not Not Observable Not Applicable Exception: Ducts located completely inside the building envelope. 403.3.5 [FR15]3 Building cavities are not used as ducts or plenums. Complies Does Not Not Observable Not Applicable Requirement will be met. 403.4 [FR17]2 HVAC piping conveying fluids above 105 ºF or chilled fluids below 55 ºF are insulated to ≥R- 3. R-_____R-_____Complies Does Not Not Observable Not Applicable Exception: Requirement is not applicable. 403.4.1 [FR24]1 Protection of insulation on HVAC piping. Complies Does Not Not Observable Not Applicable Exception: Requirement is not applicable. 403.5.3 [FR18]2 Hot water pipes are insulated to ≥R-3. R-_____R-_____Complies Does Not Not Observable Not Applicable Exception: Requirement is not applicable. 403.6 [FR19]2 Automatic or gravity dampers are installed on all outdoor air intakes and exhausts. Complies Does Not Not Observable Not Applicable Requirement will be met. 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: The Kelly Project Data filename: C:\Users\Brian_2\OneDrive - The Energy Auditor Inc\Active Incentive Contractors\Guardian Homes\2020 Mario Projects\Un-Invoiced\new man J\PLAN - Kelley, Alise & Austin\The Kelly Project.rck Page 5 of 10 11/18/20Report date: Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: The Kelly Project Data filename: C:\Users\Brian_2\OneDrive - The Energy Auditor Inc\Active Incentive Contractors\Guardian Homes\2020 Mario Projects\Un-Invoiced\new man J\PLAN - Kelley, Alise & Austin\The Kelly Project.rck Page 6 of 10 11/18/20Report date: Section # & Req.ID Insulation Inspection Plans Verified Value Field Verified Value Complies?Comments/Assumptions 303.1 [IN13]2 All installed insulation is labeled or the installed R-values provided. Complies Does Not Not Observable Not Applicable Requirement will be met. 402.1.1, 402.2.5, 402.2.6 [IN3]1 Wall insulation R-value. If this is a mass wall with at least ½ of the wall insulation on the wall exterior, the exterior insulation requirement applies (FR10). R-_____ Wood Mass Steel R-_____ Wood Mass Steel Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 303.2 [IN4]1 Wall insulation is installed per manufacturer’s instructions. Complies Does Not Not Observable Not Applicable Requirement will be met. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: The Kelly Project Data filename: C:\Users\Brian_2\OneDrive - The Energy Auditor Inc\Active Incentive Contractors\Guardian Homes\2020 Mario Projects\Un-Invoiced\new man J\PLAN - Kelley, Alise & Austin\The Kelly Project.rck Page 7 of 10 11/18/20Report date: Section # & Req.ID Final Inspection Provisions Plans Verified Value Field Verified Value Complies?Comments/Assumptions 402.1.1, 402.2.1, 402.2.2, 402.2.6 [FI1]1 Ceiling insulation R-value.R-_____ Wood Steel R-_____ Wood Steel Complies Does Not Not Observable Not Applicable See the Envelope Assemblies table for values. 303.1.1.1, 303.2 [FI2]1 Ceiling insulation installed per manufacturer’s instructions. Blown insulation marked every 300 ft². Complies Does Not Not Observable Not Applicable Requirement will be met. 402.2.3 [FI22]2 Vented attics with air permeable insulation include baffle adjacent to soffit and eave vents that extends over insulation. Complies Does Not Not Observable Not Applicable Requirement will be met. 402.2.4 [FI3]1 Attic access hatch and door insulation ≥R-value of the adjacent assembly. R-_____R-_____Complies Does Not Not Observable Not Applicable Requirement will be met. 402.4.1.2 [FI17]1 Blower door test @ 50 Pa. <=5 ach in Climate Zones 1-2, and <=3 ach in Climate Zones 3-8. ACH 50 =_____ACH 50 =_____Complies Does Not Not Observable Not Applicable Requirement will be met. 403.3.4 [FI4]1 Duct tightness test result of <=4 cfm/100 ft2 across the system or <=3 cfm/100 ft2 without air handler @ 25 Pa. For rough-in tests, verification may need to occur during Framing Inspection. _____ cfm/100 ft2 _____ cfm/100 ft2 Complies Does Not Not Observable Not Applicable Exception: All ducts and air handlers are located within conditioned space. 403.3.3 [FI27]1 Ducts are pressure tested to determine air leakage with either: Rough-in test: Total leakage measured with a pressure differential of 0.1 inch w.g. across the system including the manufacturer’s air handler enclosure if installed at time of test. Postconstruction test: Total leakage measured with a pressure differential of 0.1 inch w.g. across the entire system including the manufacturer’s air handler enclosure. _____ cfm/100 ft2 _____ cfm/100 ft2 Complies Does Not Not Observable Not Applicable Exception: All ducts and air handlers are located within conditioned space. 403.3.2.1 [FI24]1 Air handler leakage designated by manufacturer at <=2% of design air flow. Complies Does Not Not Observable Not Applicable Exception: Requirement is not applicable. 403.1.1 [FI9]2 Programmable thermostats installed for control of primary heating and cooling systems and initially set by manufacturer to code specifications. Complies Does Not Not Observable Not Applicable Requirement will be met. 403.1.2 [FI10]2 Heat pump thermostat installed on heat pumps. Complies Does Not Not Observable Not Applicable Exception: Requirement is not applicable. 403.5.1 [FI11]2 Circulating service hot water systems have automatic or accessible manual controls. Complies Does Not Not Observable Not Applicable Exception: Requirement is not applicable. 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: The Kelly Project Data filename: C:\Users\Brian_2\OneDrive - The Energy Auditor Inc\Active Incentive Contractors\Guardian Homes\2020 Mario Projects\Un-Invoiced\new man J\PLAN - Kelley, Alise & Austin\The Kelly Project.rck Page 8 of 10 11/18/20Report date: Section # & Req.ID Final Inspection Provisions Plans Verified Value Field Verified Value Complies?Comments/Assumptions 403.6.1 [FI25]2 All mechanical ventilation system fans not part of tested and listed HVAC equipment meet efficacy and air flow limits. Complies Does Not Not Observable Not Applicable Requirement will be met. 403.2 [FI26]2 Hot water boilers supplying heat through one- or two-pipe heating systems have outdoor setback control to lower boiler water temperature based on outdoor temperature. Complies Does Not Not Observable Not Applicable Exception: Requirement is not applicable. 403.5.1.1 [FI28]2 Heated water circulation systems have a circulation pump. The system return pipe is a dedicated return pipe or a cold water supply pipe. Gravity and thermos- syphon circulation systems are not present. Controls for circulating hot water system pumps start the pump with signal for hot water demand within the occupancy. Controls automatically turn off the pump when water is in circulation loop is at set-point temperature and no demand for hot water exists. Complies Does Not Not Observable Not Applicable Exception: Requirement is not applicable. 403.5.1.2 [FI29]2 Electric heat trace systems comply with IEEE 515.1 or UL 515. Controls automatically adjust the energy input to the heat tracing to maintain the desired water temperature in the piping. Complies Does Not Not Observable Not Applicable Exception: Requirement is not applicable. 403.5.2 [FI30]2 Water distribution systems that have recirculation pumps that pump water from a heated water supply pipe back to the heated water source through a cold water supply pipe have a demand recirculation water system. Pumps have controls that manage operation of the pump and limit the temperature of the water entering the cold water piping to 104ºF. Complies Does Not Not Observable Not Applicable Exception: Requirement is not applicable. 403.5.4 [FI31]2 Drain water heat recovery units tested in accordance with CSA B55.1. Potable water-side pressure loss of drain water heat recovery units < 3 psi for individual units connected to one or two showers. Potable water- side pressure loss of drain water heat recovery units < 2 psi for individual units connected to three or more showers. Complies Does Not Not Observable Not Applicable Exception: Requirement is not applicable. 404.1 [FI6]1 75% of lamps in permanent fixtures or 75% of permanent fixtures have high efficacy lamps. Does not apply to low-voltage lighting. Complies Does Not Not Observable Not Applicable Requirement will be met. 404.1.1 [FI23]3 Fuel gas lighting systems have no continuous pilot light. Complies Does Not Not Observable Not Applicable Requirement will be met. 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: The Kelly Project Data filename: C:\Users\Brian_2\OneDrive - The Energy Auditor Inc\Active Incentive Contractors\Guardian Homes\2020 Mario Projects\Un-Invoiced\new man J\PLAN - Kelley, Alise & Austin\The Kelly Project.rck Page 9 of 10 11/18/20Report date: Section # & Req.ID Final Inspection Provisions Plans Verified Value Field Verified Value Complies?Comments/Assumptions 401.3 [FI7]2 Compliance certificate posted.Complies Does Not Not Observable Not Applicable Requirement will be met. 303.3 [FI18]3 Manufacturer manuals for mechanical and water heating systems have been provided. Complies Does Not Not Observable Not Applicable Requirement will be met. Additional Comments/Assumptions: 1 High Impact (Tier 1)2 Medium Impact (Tier 2)3 Low Impact (Tier 3) Project Title: The Kelly Project Data filename: C:\Users\Brian_2\OneDrive - The Energy Auditor Inc\Active Incentive Contractors\Guardian Homes\2020 Mario Projects\Un-Invoiced\new man J\PLAN - Kelley, Alise & Austin\The Kelly Project.rck Page 10 of 10 11/18/20Report date: 2015 IECC Energy Efficiency Certificate Insulation Rating R-Value 21.00Above-Grade Wall 19.00Below-Grade Wall 0.00Floor 50.00Ceiling / Roof _______Ductwork (unconditioned spaces): Glass & Door Rating SHGCU-Factor 0.310.27Window 0.170.25Door Heating & Cooling Equipment Efficiency _______Heating System:_________________________ _______Cooling System:_________________________ _______Water Heater:___________________________ Name:Date: Comments